1. Backup Batteries Mode NiH AA 1100mAh 1 2V 5 pieces Standby 7Hrs Approx Continued Talking 2Hrs Approx Note a The battery will give the power when the normal power is off and the battery power will be off when the normal power is On b The battery is for backup power only It is not designed for normal power use 7 Antenna information Frequency range A 890 960MHz B 1710 1850MHz C 1850 1990MHz Gain 2 5dB or 5 5dB optional Connector Type SMA FME Length 3m 5m optional Weight 120g 8 The Figure Of The Termianl Series Ke Function Number y 1 Yooh Strength of the Signal i If the network is successfully 2 Register A M registered this light flashes In standby mode this light doesn t 3 Income light if there is an incoming call the light is on In standby mode this light doesn t 4 In use light When the terminal is in use the light is on 5 Power It is ON when it is powered 6 Antenna F Risa i or plugging in the antenna Port plugging SIM Card h 7 For inserting the SIM card Slot 8 Power Plug For plugging the power adapter Switch to ON side the terminal Power 9 4 power on Switch to Off side the Switch terminal power off Switch to SET side the terminal is i Setting standby for setting Switch to WORK Switch side the terminal is standby for normal using 11 USB
2. RS232 For plugging the data cable Port 12 RJ 11 Port For connecting the normal phone Installation Take off the cover of the SIM holder then insert a SIM card into the holder as below then re cover the holder Lu co Ch 0 4 Install the antenna Plug in a phone or a meter equipment into RJ 11 Port through a RJ 11 wire Plug inthe DC port ofthe adapter into the Power port the input side of the adapter should be plugged into the AC socket Input the batteries as below please be careful about the ports All the ports should be matched as the sign 10 6 All connections done then switch the power to ON side After the power is on 15 to 45 seconds Register light should be on network will be registered successfully The Y ann shows the strength of the signal Then the terminal is standby to use Warning 1 Please ensure the power switch is in OFF side before installing the terminal 2 When you assembling the antenna insert it into the antenna port in the terminal circumrotate to the best location Then screw the antenna tightly To ensure the voice quality the antenna should 1 5m or more than 1 5m far away from the terminal Important Warning f you use the antenna three or six meters long forbid taking it to the outdoors lest the lightning strike Do Use the lightning defense equipment between the antenna shelves with the do
3. fects the state of other electronic equipment for example the TV radio and so on Please keep away from these equipments when using it To make the quality best place this terminal away from metal goods and dont use the same electrical outlet with these electrical appliances which have the electromagnet interference 1 2 Warning We will never fix a terminal which has been opened by user for free And its warranty period will also be terminated 3 1 3 Confidentiality Statement The recipient of this document hereby agrees that all the information that this document contains is confidential and property of the supplier and will not be disclosed to any individual or entity without prior written consent The information ideas and strategy disclosed in this document shall remain the property of the supplier and should not be reproduced and shall be returned to the supplier promptly at its request together with all copies made thereof Recipient acknowledges that no remedy of law may be adequate to compensate the supplier for a violation of this Agreement and Recipient hereby agrees that in addition to any legal or other rights that may be available in the event of a breach hereunder the supplier may seek equitable relief to enforce this agreement in any Court of competent jurisdiction 2 Packing List Check all the components according to the packing list when you open the package Please contact with the dealer or seller in
4. fixed Cellular Terminal FCT 11M USER MANUAL 1 Instruction onere n a aa Aat a md 2 1 1 Safely instruction essere 2 1 2 Waring io erm ee ees 3 1 3 Confidentiality Statement 4 2 PACKING List eer ees 5 3 Main function eere rre d aa 5 4 XApplicatiom 2 iet erret eed cae 6 5 Parameter elect te eee tee eei ve lane dens 6 6 Power Specification 7 7 Antenna information nenea nana ana 8 8 The Figure Of The Termianl sess 8 9 Installations scie detii 10 10 Operation Instruction nenea nana emana emana na 11 El ALEN ON e eee eee aaa da 13 12 Epidemic Failure eterne 13 13 Maintain Your Terminal eene 15 1 Instruction This terminal is independently designed and manufactured with the advanced GSM wireless technology in the world It is convenient to be connected with various systematic mobile telecommunication networks at present This system has a high sensitivity of receiving signals and large transmitting power which greatly expands the effective coverage of GSM cellular network It also features in shaking resistance moisture proof voltage fluctuating bearing It is widely used in mobile communications intercommunications and inner communications to realize the good utility of resources Furthermore it provides conveniences and safety for enterprises in wireless and remote uses It is safe and reliable because of
5. m volume 11 Attention 1 Signal Shield Before using the terminal please confirm there isn t any restriction for wireless signal in the area Interference Same as all wireless eguipments the terminal maybe interfered the voice guantity maybe infected Exclusion Area Don t use the terminal at the place where marked Turn off wireless equipments or any potential blast area Accessories Just use the accessories coming with the terminal such as Antenna Adapter and the batteries Please be careful the usage of the batteries Settings Before using the terminal the terminal should be initialized by the dealer or the network operator Don t change the settings optional Usage Dont operate other ports Setting port amp Download port except Power Switch 12 Epidemic Failure Can t 1 Check if the SIM card is placed well Register 2 Check if the SIM Card is locked You can check 13 it by using mobile phone No Signal If the strength of the signal is low or the gain of the antenna is low check if the antenna is connected well Power 1 Check if the adapter is connected well with the Light AC socket Check if the Plug in is connected Doesn t On well with the terminal 2 The adapter is broken Bad voice 7 Change a phone quality 8 The terminal should be far away from the antenna 9 Put the antenna in the area where it can receive signal well No Ring 1 The phone is br
6. no radiations in the terminal 1 1 Safely instruction z This Section provides various safety guidelines Read this information before using your terminal called terminal throughout this guide Failure to comply with these guidelines could prove either dangerous or illegal amp Clean with the wet or anti static cloth do not use the dry cloth or static cloth Don t use chemical product to clean the surface of your terminal Shutdown your terminal when cleaning amp 3 Do not expose to strong direct sunlight amp Avoid any liquid substances entry the inside of your terminal 2 Avoid dropping and other rough treatment to the terminal Only connect your terminal with the concurrent device REE Only use the power adapter specify by the manufacturer Use other adapters or batteries may bring in danger Never use any chargers or batteries which are damaged amp Do not use the non chargeable batteries or them may explode please let the batteries charged for 12 hours or more before its first use amp 3 Don t use this terminal near the gas station oil depot chemical storage medical equipment or dangerous substances and the area that indicated something like switch off the any cordless radio equipment Observe restrictions and follow any regulations or rules that are in force amp This terminal is an indoor terminal don t use it out doors and pause using it when lightning storm amp 5 This cordless phone maybe af
7. oken 2 The terminal is broken In this case you may contact your after sales services Can t Dial 1 Network problem can t register the network well 2 Check if the forbidden number has been set Please contact your local retailer 3 Terminal failures Please contact after sales services Can t 1 Check it to see whether the metering machine Meter is well connected with the terminal Fasten the Tariffs RJ 11 port if necessary 14 2 Check the metering machine to see whether it works well 13 Maintain Your Terminal amp Keep it dry Humidity and liguids contain mineral that will corrode electronic circuits amp Keep it in room temperature High temperatures can shorten the life of electronic devices damage batteries and make certain plastics warp or melt amp Do not drop knock or shake it Rough handling would break internal circuit boards amp 5 Do not use or store it in dusty dirty areas Its moving parts can be damaged amp Do not use chemicals material to clean it Wipe it with a dampened cloth slightly 15
8. time when you find some missing or destroyed lt 7 m 1 Terminal 2 Adapter 3 Batteries Antenna 5 User Manual 6 Rj11 Wire optional A 3 Main function Perfect voice quality Strong capacity of resisting disturbance Good appearance convenient to install or operate amp High sensitive of receiving and sending and strong sending power Emulate switching equipment function provide 5 dialing tone FSK dialing Ring stream signal Precision reversal polarity signal time metering function Phone SI M card locking function Support Office PBX Backup power system EER cm B Application Wireless public terminal Wireless terminal for company support PABX amp VOI P Convenient switch in for home usage SW Nb Mobile communication Ship Train or any other moving facility 5 Parameter Descriptions Unit Specifications Working UP MHz 890 915 1710 1785 1850 1910 Frequency DOWN MHz 935 960 1805 1850 1930 1990 Transmitting W lt 2W Receiving dBm 103 Gain dBm 2 Atmosphere Kpa 86 106 Ambience Temp 0 C 55 C Relative Humidity 10 95 Environmental dB lt 60dB A Freguency Stability Better than 2 5PPM Maximum Distance Between lt Phone and 100 Terminal 6 Power Specification Power Mode AC to DC Switch adaptor 110 240V DC7 5V 1 5A Switch adaptor 110 240V DC12V 1 0A
9. wn lead if you use the antenna ten meters long Installing outdoor antenna and lighting defense device all figures just as a reference way 10 Operation Instruction 1 Make outgoing calls a Make a call Pick up the hand set or press Handsfree key 11 the In Use light on You could make a call while hearing a dial tone Then you can dial the number you want Meantime if the terminal is connected with a meter equipment the equipment will show the dialed number and start the metering when the receiver answers the phone b Quick dialing When you input the number you want to dial follow a key then the call will be get through directly If don t input key the call will be get through after 5 seconds C Forbidden call f the number you dial is forbidden the terminal won t put the call through At the same time the terminal will beep up du du du sound to indicate that you hang up the phone 2 Receive incoming calls Receive call When there is an incoming call the phone will ring INCOME light is on You pick up the handset or press the Handsfree to receive the incoming call If the terminal is not limited tariffs for incoming calls it will start metering as soon as you pick up the receiver 3 Adjust volume Pick up the receiver or press Handsfree key press X for different volume levels on the keyboard Note X 1 5 1 is the minimum volume and 5 is the 12 maximu