PACSystems RX3i PROFINET Scanner, IC695PNS001

image

Contents

1. features introduced in the PNS release Controller CPU firmware CPU315 CPU320 firmware version 7 10 or later CPE305 CPE310 firmware version 7 10 or later RXi Controller firmware version 7 80 or later Programmer software Proficy Machine Edition version 8 0 or later RX3i PROFINET Controller IC695PNCO001 with firmware version 1 20 or later RX3i backplane hardware The following minimum backplane hardware revision must be used IC695CHS012 BAMP IC695CHS016 BAMP IC695CHS012CA BAMP IC695CHS016CA BAMP or IC695CHS012 CA or later IC695CHS016 CA or later IC695CHS012CA CA or later IC695CHS016CA CA or later or IC695CHS007 AA or later When installing operating or maintaining the ICG95PNSO01 personnel must insure any electrostatic charge is discharged through the use of a grounded ESD strap or other means This requirement does not apply if the IC695PNS001 is used with the following backplane revisions IC695CHS012 EA or later IC695CHS016 EA or later IC695CHS012EA CA or later IC695CHS016EA CA or later or IC695CHS007 BA or later Small form factor pluggable modules IC695SPC100A or later IC695SPFO002A or later IC695SPF550A or later IC695SPF010A or later RX3i modules For a complete list refer to Supported Modules Power Supplies and Backplanes on page 9 IC695PNSOO1 ABAC PROFINET Scanner Module 13 GFK 2758C New Features and Enhancements in this Release Rel
2. connector Visually inspect the module to be sure it is properly seated Secure the bottom of the module to the backplane using the machine screws provided with the module 3 Tighten the heat sink screw on the front of the module in the threaded hole in the backplate to 6 in Ibs using a flat tip screwdriver 3 Connecting the PNS to the PROFINET network and to a 10BaseT 100BaseTX or 1000BaseT IEEE 802 3 network for general Ethernet communications Do not connect two or more ports on the PNS to the same device either directly or indirectly Each port on an RX3i PNS operates independently so devices that operate at different speeds and or duplex modes may be attached to the ports By default all ports including empty unconfigured SFP cages are set for Automatic which enables auto negotiation for the widest range of options supported by the port For other options refer to the user s manual GFK 2737 Bottom of module Port1 Port3 Port 2 Port 4 8 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C 4 Installing SFP devices Optical SFPs use an invisible laser to generate a fiber optic signal Always keep the port covered if a cable is not installed Do not look into the open port if a cable is not installed If the surrounding air operating temperature of the PNS is greater than 40 C SFP devices could have operating temperatures over 70 C 158 F Under these conditions for your safety do not use bare
3. hot inserting an I O Module the PNS could disable outputs on other Output Modules in the rack to their Default Hold Last State operation and mark Input Module data as bad in PROFINET messages back to the IO Controller For GE IP controllers this is represented as IO Point Fault contacts This could occur for up to 5ms and then I O continued normally RX3i PNS names starting or ending with a hyphen not prevented from storing to the RX3i PNS from an SD Card PROFINET specifies that IO Device names should neither start nor end with a hyphen Previous releases did not prevent names starting or ending with a hyphen from being stored to the RX3i PNS from the SD Card Restrictions and Open Issues in this Release Subject Description PROFINET connection losses with MRP enabled and IO update rates of 1 ms Applications with MRP Ring network topologies and IO Devices configured with IO Update Rates of 1 ms on either 100 Mbps or 1000 Mbps may encounter PROFINET Connection Losses of PROFINET IO Devices during a ring break event Use of MRP with 1 ms IO Update rates is not recommended with this release Refer to Media Redundancy Protocol Support in the PACSystems RX3i PROFINET Scanner Manual GFK 2737 for details on recommended MRP configurations Connecting Ethernet ports not configured as ring ports to the MRP ring may inhibit ring break detection In order to insure correct MRP ring break detection it is im
4. 693MDL732 8 Circuit Output 12 24 VDC 0 5A Positive IC693MDL733 8 Circuit Output 12 24 VDC 0 5A Negative IC693MDL734 6 Circuit Output 125 VDC 1A Positive Negative IC693MDL740 16 Circuit Output 12 24 VDC 0 5A Positive IC693MDL741 16 Circuit Output 12 24 VDC 0 5A Negative IC693MDL742 16 Circuit Output 12 24 VDC 1A Positive IC693MDL748 8 Circuit Output 48 VDC 0 5A Positive IC693MDL752 32 Circuit Output 5 24 VDC 0 5A Negative IC693MDL753 32 Circuit Output 12 24 VDC 0 5A Positive IC693MDL754 32 Circuit Output 24 VDC 0 75A Positive Diagnostics Off IC693MDL754 32 Circuit Output 24 VDC 0 75A Positive Diagnostics On IC693MDL760 Solenoid Valve Output Module IC693MDL916 16 Circuit Output 4A Relay IC693MDL930 8 Circuit Output 4A Relay Isolated IC693MDL931 8 Circuit Output Relay Form BC Isolated IC693MDL940 16 Circuit Output 2A Relay IC694MDL310 12 Circuit Output 120 VAC 0 5A IC694MDL330 8 Circuit Output 120 240 VAC 2A IC694MDL340 16 Circuit Output 120 VAC 0 5A IC694MDL350 16 Circuit Output 120 240 VAC Isolated IC694MDL390 5 Circuit Output 120 240 VAC 2A Isolated IC694MDL732 8 Circuit Output 12 24 VDC 2A Positive IC694MDL734 6 Circuit Output 125 VDC 1A Positive Negative IC694MDL740 16 Circuit Output 12 24 VDC 0 5A Positive IC694MDL741 16 Circuit Output 12 24 VDC 1A Negative IC694MDL742 16 Circuit Output 12 24 VDC 1A Positive IC694MDL752 32 Circuit Output 5 24 VDC 0 5A Negative IC694MDL753 32 Circuit Output 12 24 VDC 0 5A Positive IC694MDL754 32 Circu
5. NET Scanner Module GFK 2738C Supported Modules Power Supplies and Backplanes The following modules can be used with this release of the RX3i PROFINET Scanner IO Device icesswpieso 8 Circutinput BOVACisoated eo iossoWDies 8 Circuit Input 240 VAC Isolated om icesswDLese 8 Circuit input 125 VDC Positve 7 Negative Loge Si icesoWDLes4 8 Circuit input 24 VDC Positive Negatve Logic em ceeamDL280 8 Circuitinput 70 VAC ise Ooo eo icswDi2s 8 Cireutinput 240 VAG isolated em icesdDLes Circuit Input 125 VDO Positive Negatve Loge em iceDLes4 8 Circuit Input 24 VDC Positive Negative Loge em 1 The PNS cannot distinguish between modules within the same Distinguishing Class type This means that any module physically present that is within the same class as the one configured will not alert the user with a System Configuration Mismatch fault on the Controller Fault Table See GFK 2222 Chapter 3 for CPU operation during System Configuration Mismatch faults The PNS currently does not support Fault Reporting from this module 10 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C T Distinguishing Catalog Number Module Description Classes Discrete Output Modules 16 out IC693MDL350 16 out IC693MDL390 5 Circuit Output 120 240 VAC 2A Isolated IC693MDL730 8 Circuit Output 12 24 VDC 2A Positive IC693MDL731 8 Circuit Output 12 24 VDC 2A Negative IC
6. PACSystems RX3i IC695PNSOO1 ABAC GFK 2738C PROFINET Scanner Module July 2013 um The PACSystems RX3i PROFINET Scanner PNS module IC695PNS001 1 OOok connects a remote universal RX3i I O rack of Series 90 30 or RX3i modules to a 2 Q LAN PROFINET IO Controller The PROFINET Scanner scans the modules in its rack 3 OO status retrieving input data and providing output data and exchanges that data on the PROFINET IO LAN at the configured production rate The PNS manages PROFINET communication and module configuration PNS001 between an lO Controller and modules in the remote rack If network mE communications are lost the PNS manages IO states according to the individual TO INSTALL module configurations The PNS supports 10 100 1000 Mbps Copper 100 1000 Mbps Multi mode Fiber and 100 1000 Mbps Single mode Fiber PROFINET communications on the network require 100 or 1000 Mbps link speed Although 10 Mbps cannot be used for PROFINET communications 10 Mbps can be used for other types of Ethernet traffic such as PING Features of the RX3i PNS include Programming and configuration services for all supported Series 90 30 and RX3i IO Modules using Proficy Machine Edition For a list of currently supported IO modules see Supported Modules Power Supplies and IP ADDRESS Backplanes on page 9 4QO CONN Support for daisy chain line star or ring redundant media topologies MAC ADDRESS Four switched Ethernet ports two 8
7. a module for the already utilized slot will result interface of HWC in a Loss of I O Module fault The PNS module is supported only in The RX3i PROFINET Scanner module is configurable for use in Slot 1 Slot 2 certain backplane slots and when installed in the IC695CHS007 backplane also Slot 6 Explore PROFINET Networks tool not The Proficy Machine Edition Explore PROFINET Networks tool does not supported on submodules return submodule information for IO modules within its RX3i rack in this release Submodule information for the RX3i PNS itself is returned SFP modules do not support hot swap In this release of the RX3i PNS SFP modules do not support hot swap This means that if an SFP module is hot inserted into the RX3i PNS no Fault Table entry will be logged and configuration parameters will not be applied to the SFP until the RX3i PNS is power cycled Until the RX3i PNS is power cycled the SFP will remain enabled and active with auto negotiation turned on IO modules hot inserted while an If an invalid configuration for an IO module in the PNS is stored to the CPU invalid configuration is stored require such as a default value outside the engineering units range and the IO re insertion or power cycle to recover module using that configuration is hot inserted in the PNS the hot insertion process fails No Addition of IO Module fault is generated and the module is left at its default operation The configuration of that module will n
8. atal error module location identification microprocessor over temperature and update conditions For details on these blink patterns refer to PACSystems RX3i PROFINET Scanner Manual GFK 2737 OK LED The OK LED indicates whether the module is able to perform normal operation Green on OK O Off Not OK LAN LED The LAN LED indicates access to and activity on the Ethernet network The LAN LED indicates network packets are being processed by the network interface not just passing through the embedded switch D Blinking on The module s network interface is active Q Off No activity STATUS LED The STATUS stays Green during normal operation Q Green on Normal Operation Red blinkin g A MAC address read from nonvolatile memory is invalid Ports with invalid MAC addresses remain disconnected from the Ethernet network CONN LED The CONN LED indicates the status of PROFINET connections Green on At least one PROFINET connection AR exists with an IO Controller O Amber blinking No device name configured O Off No PROFINET connection AR exists Port LEDs The PROFINET Controller has four Port LEDs PORT1 PORT2 PORTS and PORTA that indicate link speed link connection and link activity corresponding to the four possible external Ethernet ports Blue on Link connected 1000 Mbps Blue blinking Port a
9. conductor RJ 45 shielded twisted pair 10 100 1000 Mbps copper interfaces and two Small Form factor Pluggable SFP cages for user supplied SFP devices The network can include media interfaces of more than one type Support for transfer of IO Device Name to another PNS module using an SD card This eliminates the need to connect a configuration tool such as Proficy Machine Edition when replacing a module AUSB port for field updates of firmware using WinLoader Note The USB port is for firmware upgrades only It is not intended for 10 DEVICE permanent connection Ordering Information IC695PNS001 PACSystems RX3i PROFINET Scanner Module 10 100 1000 with four Ports two SFP connections two Copper Includes a blank SD card two mounting screws and a USB port cover IC695SPC100 RX3i 10 100 1000Base T copper SFP IC695SPF002 RX3i 100Base FX fiber 2 km SFP Multi mode fiber MMF IC695SPF550 RX3i 1000Base SX fiber 550 m SFP MMF IC695SPF010 RX3i 1000Base LX fiber 10 km SFP Single mode fiber SMF Indicates a trademark of GE Intelligent Platforms Inc and or its affiliates All other trademarks are the property of their respective owners 2 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C PNS Specifications PROFINET Support PROFINET Version 2 3 Class A IO Device Controller CPU Version Required CPU315 CPU320 with firmware version 7 10 or later CPES305 CPE310 with firm
10. ctive 1000 Mbps Green on Link connected 100 Mbps Green blinking Port active 100 Mbps Purple on Link connected 10 Mbps Purple blinking Port active 10 Mbps Off The associated Ethernet port is not connected to an active link e O00800 9 Red on Port 3 and port 4 only Incompatible SFP plugged into port 6 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C ACTIVE LED The active LED indicates the Scanner is connected to a PROFINET IO Controller that is controlling the IO data for the PNS s IO modules e Green on PNS is connected to a PROFINET IO Controller that is controlling IO Module IO data Q Off PNS is not connected to a PROFINET IO Controller USB LED The USB LED indicates activity on the USB port e Green on A USB cable is connected D Green blinking USB port activity Q Off No USB port activity Quick Start Guide Installation and initial startup procedures for the PNS include the following steps Before installing and operating the PNS refer to the PACSystems RX3i PROFINET Scanner Manual GFK 2737 for detailed information 1 Pre Installation check Upon receiving your RX3i equipment carefully inspect all shipping containers for damage If any part of the System is damaged notify the carrier immediately The damaged shipping container should be saved as evidence for inspection by the carrier As the consignee it i
11. ease 1 10 adds support for the following RX3i modules IC695MDL664 16 Circuit Smart Input 24VDC Positive Logic Operational Notes o Options related to Fault Reporting are not currently supported o Configuration rule checking is performed by the PROFINET Scanner at PROFINET connection time Rule check failures will transition the module to default operation and point faults energized for assigned I O See the PACSystems RX3i PROFINET Scanner Manual GFK 2737A for additional details IC695MDL765 16 Circuit Smart Output 24 125 VDC 24A Positive Logic Operational Notes o Options related to Fault Reporting are not currently supported o Output Command Feedback data is not currently supported o Configuration rule checking is performed by the PROFINET Scanner at PROFINET connection time Rule check failures will transition the module to default operation and point faults energized for assigned I O See the PACSystems RX3i PROFINET Scanner Manual GFK 2737A for additional details IC695ALG508 8 Channel Isolated RTD Input Operational Notes o Options related to Fault Reporting are not currently supported o Options related to Interrupts are not currently supported o Options related to Rate of Change are not currently supported O Configuration rule checking is performed by the PROFINET Scanner at PROFINET connection time Rule check failures will transition the module to default operation and point faults energ
12. enclosure that can be accessed only by the use of a tool The following information is for products bearing the UL marking for Hazardous Locations or ATEX marking for explosive atmospheres EQUIPMENT LABELED WITH REFERENCE TO CLASS GROUPS A B C amp D DIV 2 OR ZONE 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS DIVISION 2 GROUPS A B C D ZONE 2 OR NON HAZARDOUS LOCATIONS ONLY WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 OR ZONE 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES AND WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS PROFINET Scanner Status and Control Data The RX3i PROFINET Scanner provides 32 bits of input status data and receives 32 bits of output control data The application program in the IO Controller system can monitor the input status bits for the PNS module The output control bits are reserved for future use and have no function at this time Output Control Bits The PROFINET Scanner s 32 bits of control output are reserved for future use Input Status Bits The PROFINET Scanner s 32 bits of input status provide information about the scanner All status bits are active high Status Name Description Bits 1 Module Indicates the health of the mod
13. figuration software that supports GSDML V2 3 MenuList elements such as Proficy Machine Edition 8 0 or later is required to display the configuration parameters of most IC695xxx I O modules For product standards general operating specifications and installation requirements refer to the PACSystems RX3i System Manual GFK 2314 Additional Information For additional information please refer to the manuals listed below Manuals can be downloaded from the Support website http support ge ip com PACSystems RX3i PROFINET Scanner Manual GFK 2737 PACSystems RX3i PROFINET Controller Manual GFK 2571 PACSystems RX3i PROFINET Controller Command Line Interface Manual GFK 2572 PACSystems CPU Reference Manual GFK 2222 PACSystems RX3i System Manual GFK 2314 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C General Installation Requirements This product is intended for use with the RX3i system Its components are considered open equipment having live electrical parts that may be accessible to users and must be installed in an ultimate enclosure that is manufactured to provide safety As a minimum the enclosure shall provide a degree of protection against solid objects up to 12mm e g fingers This equates to a NEMA UL Type 1 enclosure or an IP20 rating IEC60529 providing at least a pollution degree 2 environment Installation in Hazardous Areas The system containing the RX3i PNS001 module must be mounted within an ultimate
14. hands to remove an SFP device from the SFP cage Use protective gloves or a tool needle nose pliers to avoid handling the hot SFP device directly when removing the SFP device For a list of SFP module types and network cabling details refer to SFP Modules for Ethernet Ports in the PACSystems RX3i PROFINET Scanner Manual GFK 2737 5 Installing the USB port driver optional The PNS provides a micro USB port for connection to a computer running Windows 2000 Windows XP Windows Vista or Windows 7 operating system The USB port is used only for firmware updates USB driver files are provided as part of upgrade packages compatible with the PROFINET Scanner The PNS includes a driver install application that can be used to enable a computer to communicate with a PNS via its USB port 6 Assigning an IO Device Name to the PNS Before attempting to connect to or configure the RX3i PNS the IO Device Name must be set with a Discovery and Configuration Protocol DCP tool such as the Proficy Machine Edition Discovery Tool 7 Configuring the PNS and its IO Modules on a PROFINET network Proficy Machine Edition is the primary tool used to configure an RX3i PROFINET network The PNS must be installed in the slot that is selected in the module s hardware configuration The GSDML file for the RX3i PNS is included with Proficy Machine Edition To obtain the GSDML for import into a 3 Party tool contact GE Technical Support IC695PNSOO1 ABAC PROFI
15. ional 120 240 VAC 125VDC 40W Power Supply 24VDC 40W Power Supply Multifunctional 24VDC 40W Power Supply Small Form factor Pluggable SFP Modules 10 100 1000Base T Copper SFP 100Base FX fiber 2km SFP 1000Base LX fiber 10km SFP 1000Base SX fiber 550m SFP The RX3i PROFINET Scanner can be used in the following PACSystems backplanes Catalog Number Backplane Type IC695CHS007 7 Slot RX3i Universal Backplane IC695CHS012 12 Slot RX3i Universal Backplane IC695CHS016 16 Slot RX3i Universal Backplane 3 The PNS currently does not support Fault Reporting or Interrupts from this module The PNS cannot distinguish between the different rack sizes Choosing the wrong type will not generate a System Configuration Mismatch fault on the Controller Fault Table 11 12 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C Release History Firmware Version Revision Date Comments IC695PNS001 ABAC 1 10 July 2013 Support for additional RX3i I O modules listed in New Features and Enhancements in this Release on page 13 IC695PNS001 ABAA 1 00 June 2013 Hardware update for improved manufacturability No changes to features functions or compatibility IC695PNS001 AAAA 1 00 March 2013 Initial release Important Product Information for this Release Compatibility The following CPU firmware programming software and backplane hardware versions are required to use the
16. it Output with ESCP IC694MDL916 16 Circuit Output 4A Relay IC694MDL930 8 Circuit Output 4A Relay Isolated IC694MDL931 8 Circuit Output Relay Form BC Isolated IC694MDL940 16 Circuit Output 2A Relay IC695MDL765 16 Circuit Smart Output 24 125 VDC 2A Positive Logic Discrete Mixed Modules 8 Circuit Mixed 120 VAC Input Relay Output 8 Circuit Mixed 24 VDC Input Relay Output IC693MAR590 IC693MDR390 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2758C PT Distinguishing Catalog Number Module Description Analog Input Modules IC694ALG222 IC694ALG223 IC695ALG616 16 Point Analog Voltage Input 16 Point Analog Current Input 16 Point Analog Current Voltage Input ALG IN 16 ALG IN 16 none IC693ALG390 IC693ALG391 IC693ALG392 IC694ALG390 IC694ALG391 IC694ALG392 IC695ALG708 Analog Output Modules 2 Point Analog Voltage Output 2 Point Analog Current Output 8 Point Analog Current Voltage Output 2 Point Analog Voltage Output 2 Point Analog Current Output 8 Point Analog Current Voltage Output 8 Point Analog Current Voltage Output ALG OUT 2 ALG OUT 2 ALG OUT 8 ALG OUT 2 ALG OUT 2 ALG OUT 8 none IC693ALG442 IC694ALG442 Analog Mixed Modules 4 Input 2 Output Current Voltage 4 Input 2 Output Current Voltage ALG IN 4 ALG OUT 2 ALG IN 4 ALG OUT 2 IC695ALG508 RTD Input Modules 8 Channel Isolated RTD Input Power Supply Modules Universal 120 240 VAC 125VDC 40W Power Supply Multifunct
17. ity Information not available STATUS LED blinks red with special blink code Fatal initialization failure OK LAN and STATUS LEDs blink green in unison 0 5 second ON 0 5 second OFF Invalid firmware detected or firmware update initiated Module is waiting for firmware update Blink pattern continues during firmware update After the automatic update completes the LAN and STATUS LEDs blink amber and the module resets which restarts the powerup process STATUS and LAN LEDs blink green in unison 0 5 seconds ON 0 5 seconds OFF Internal update in process following a firmware update Unit should complete update and restart automatically 3 LAN and STATUS LED solid green Normal operation 4 OK LED solid green Normal operation Powerup completed Note Ole ko ero 3 OO STATUS ZOO Neo Q PNS001 ec TO INSTALL TORQUE TO 6 IN LB Q ACTIVE USB sli IP ADDRESS MAC ADDRESS 10 DEVICE Under certain ambient operating temperatures the PROFINET Scanner could momentarily display the over temperature pattern during power up while it is calibrating its thermal protection functions This indication can be ignored For details see Microprocessor Over Temperature in the PACSystems RX3i PROFINET Scanner Manual GFK 2737 IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2758C Normal Operation of Individual LEDs The PNS s LEDs can operate in tandem to indicate f
18. ized for assigned I O See the PACSystems RX3i PROFINET Scanner Manual GFK 2737A for additional details IC695ALG616 16 Channel Analog Input Current Voltage Operational Notes o Options related to Fault Reporting are not currently supported o Options related to Interrupts are not currently supported o Options related to Rate of Change are not currently supported o Configuration rule checking is performed by the PROFINET Scanner at PROFINET connection time Rule check failures will transition the module to default operation and point faults energized for assigned I O See the PACSystems RX3i PROFINET Scanner Manual GFK 2737A for additional details IC695ALG708 8 Channel Analog Output Current Voltage Operational Notes o Options related to Fault Reporting are not currently supported o Options related to Interrupts are not currently supported o Output Command Feedback Reference data is not currently supported O Configuration rule checking is performed by the PROFINET Scanner at PROFINET connection time Rule check failures will transition the module to default operation and point faults energized for assigned I O See the PACSystems RX3i PROFINET Scanner Manual GFK 2737A for additional details 14 GFK 2758C IC695PNSOO1 ABAC PROFINET Scanner Module Problems Resolved by this Revision Subject Description Loss of IO During Hot insertion of I O module In earlier versions while
19. ot be retried until the module is re inserted or the PNS rack is power cycled even if the configuration is corrected in the CPU
20. ply to the main PLC rack IC695PNSOO1 ABAC PROFINET Scanner Module 15 GFK 2738C Operational Notes IOPS of power supplies do not update The IOPS status of a power supply is marked good or bad at the start of when power supply is switched off each PROFINET IO connection The IOPS is not updated when the power supply is turned on and off RX3i PNS allows firmware update The RX3i PNS does not prevent initiation of module Firmware Update via while connected to a running Winloader if it is actively connected to an IO Controller Do not initiate PROFIENT IO Controller Firmware Update of an RX3i PNS until you have placed its controlling PROFINET IO Controller into Stop mode no longer driving output and collecting inputs from the RX3i PNS Port LED for Ethernet ports configured During power up the Port LEDs of the RX3i PNS Ethernet ports configured to 100 Mbps may briefly flash blue for 100 Mbps operation may briefly flash blue before turning green The port before changing to green remains configured for 100 Mbps operation during the power up process and afterwards PROFINET Alarms are not supported PROFINET Alarms are not issued from the RX3i PNS in this release Some power supplies use two Note that the IC695PSA040 and IC695PSA140 each utilize two backplane backplane slots but this is not slots but are shown using only one slot in the Change Module List interface indicated in the change module list for the RX3i PNS Configuring
21. portant to connect the correct Ethernet ports of the RX3i PNS to the MRP ring The ports connected to the ring must be the same ports configured as MRP Ring Ports Failure to connect the configured ports will prevent the PNS from correctly participating in the MRP ring may inhibit ring break detection and may result in losses of IO Devices upon ring break events It is recommended during System commissioning that the physical network connections be verified with the system configuration for ring ports in system s hardware configuration Refer to Media Redundancy Protocol Support in the PACSystems RX3i PROFINET Scanner Manual GFK 2737 for details on recommended MRP configuration More than three ALG508 ALG616 ALG708 modules in a PNS rack cause system to transition to STOP FAULTED during store of hardware configuration IC695ALG508 IC695AL G616 IC695ALG708 modules have larger configurations than other modules If more than three of these modules are placed in a PNS rack an IOC Software Fault Module Firmware Fault could be generated on the RXi Controller v7 80 or earlier or RX3i PNC v1 22 and earlier If this happens the system will go to STOP FAULTED state Future versions of the RXi Controller and IC695PNCO01 firmware will remove this restriction With the current PNC or RXi firmware you must limit the number of ALG508 ALG616 and ALG708 modules to three in a single PNS rack to avoid this issue This limit does NOT ap
22. s your responsibility to register a claim with the carrier for damage incurred during shipment However GE Intelligent Platforms will fully cooperate with you should such action be necessary After unpacking the RX3i equipment record all serial numbers Serial numbers are required if you should need to contact Customer Care during the warranty period All shipping containers and all packing material should be saved should it be necessary to transport or ship any part of the system 2 Installing the PNS in an RX3i backplane The Scanner can be installed in slot 1 or 2 of a 7 12 or 16 slot RX3i Universal Backplane or in slot 6 of a 7 slot RX3i Universal Backplane The installation slot must match the slot that is selected in the module s hardware configuration The back of the PNS has an exposed heat sink and backplane connector Before inserting the module into the backplane the removable conduction cooling cover must be removed from backplane Removable plastic for the module s heat sink IC695PNSOO1 ABAC PROFINET Scanner Module GFK 2738C RX3irack power must be turned off The PNS does not support insertion removal while power is applied to the system hot swap Holding the module firmly align the module with the correct slot and connector Engage the module s rear pivot hook in the notch on the top of the backplane 1 Swing the module down 2 until the module s connector engages the backplane s backplane
23. ule A value of 0 indicates the module is powering up or has OK failed A value of 1 indicates the module is functioning properly 2 Reserved Setto 0 3 Porti Link 1 port is connected to another device and is communicating Up 0 port is not connected to another device or the port has some sort of error preventing 4 Port Link communications Up 5 Port3 Link Up 6 Port4 Link Up 7 10 Reserved Setto 0 11 MRP Indicates whether MRP has been enabled or not A value of 0 indicates that MRP is not Enabled enabled A value of 1 indicates that MRP is enabled 12 MRP Role Indicates the MRP role the PNS is operating as when MRP is enabled A value of 0 indicates that the PNS is currently an MRP Client A value of 1 indicates that the PNS is currently an MRP Manager however the PNS does not currently support MRP Manager configuration If MRP is not enabled then this bit will be set to zero 13 32 Reserved Setto 0 4 GFK 2758C IC695PNSOO1 ABAC PROFINET Scanner Module LEDs on the PROFINET Controller Module Powerup LED Patterns At powerup the LEDs show the patterns described below The LEDs also blink diagnostic patterns for certain operating errors and for module identification Step LED Blink pattern Description 1 All LEDs off Initial state 2 STATUS LED solid green Normal operation OK LED blinks amber with special blink code Fatal initialization or diagnostics failure H W Module Ident
24. ware version 7 10 or later RXi Controller firmware with version 7 80 Proficy Machine Edition Version Required Version 8 0 or later Power Requirements 3 3V 1 2A with no SFP devices installed 1 9A maximum two SFP devices installed 0 35A per SFP 5V 1 1A maximum Operating Temperature Range 0 to 60 C Derated to 57 C e If 100MB Fiber SFPs installed or f Copper SFPs operating at 1GB Number of Port Connectors Two RJ 45 and Two SFP Cages SFP devices not included available separately USB Connector for firmware upgrades One Micro B connector USB 2 0 compliant running at Full speed 12 MHz SD Card Supports SD and SDHC cards PNS Status and Control Bits 32 input status bits and 32 output control bits PROFINET IO production rate IO Update Rate Configurable selections 1ms 2ms 4ms 8ms 16ms 32ms 64ms 128ms 256ms or 512ms Number of IP addresses One Supports Classless Inter Domain Routing CIDR Number of MAC Addresses Five One per external port and one internal IO Station Maximum Limits Number of IO Modules per station Number of backplane slots minus one for PNS and at least one for a power supply IO data per station 2880 bytes total 1440 bytes of input data 1440 bytes of output data Configuration V2 3 GSDML file is included with Proficy Machine Edition available for import into 3 Party tools Note Con