1. Issue Date 2007 07 09 Page 15 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 7 Overcurrent and earth fault protection in primary circuits N A 2 7 1 Basic requirements Class IIl equipment N A Instructions when protection relies on building N A installation 2 7 2 Faults not covered in 5 3 N A 2 7 3 Short circuit backup protection N A 2 7 4 Number and location of protective devices h N A 2 7 5 Protection by several devices N A 2 7 6 Warning to service personnel N A 2 8 Safety interlocks N A 2 8 1 General principles No safety interlock used N A 2 8 2 Protection requirements N A 2 8 3 Inadvertent reactivation N A 2 8 4 Fail safe operation N A 285 Moving parts NA 2 8 6 Overriding N A 2 8 7 Switches and relays N A 2 8 7 1 Contact gaps mm eee eee eee N A 2 8 7 2 Overload test N A 2 8 7 3 Endurance test N A 2 8 7 4 Electric strength test N A 2 8 8 Mechanical actuators N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 16 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 9 Electrical insulation Pass 2 9 1 Properties of insulating materials Natural rubber materials Pass containing asbestos and hygroscopic materials are not used as insulation 2 9
2. Issue Date 2007 07 09 Page 32 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict B Annex B MOTOR TESTS UNDER ABNORMAL CONDITIONS see 4 7 2 2 and N A 5 3 2 B 1 General requirements N A 08 0 EE Manufacturers ea aa TYPE ai die ai h eis de ee ede nte ri Rated values eee B 2 Test conditions N A B 3 Maximum temperatures N A B 4 Running overload test N A B 5 Locked rotor overload test N A Test duration days Electric strength test test voltage V B 6 Running overload test for d c motors in secondary NA circuits B 7 Locked rotor overload test for d c motors in secondary circuits N A B 7 1 Test procedure NA B 7 2 Alternative test procedure test time h N A B 7 3 Electric strength test NA B 8 Test for motors with capacitors NA B 9 Test for three phase motors NA B 10 Test for series motors N A Operating voltage V Underwriters Laboratories Inc Issue Date 2007 07 09 Page 33 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict C Annex C TRANSFORMERS see 1 5 4 and 5 3 3 N A POSIOM aian a a Sa D AA S
3. supplementary insulation IEC 60950 1 Clause Requirement Test Result Remark Verdict 3 WIRING CONNECTIONS AND SUPPLY Pass 3 1 General Pass 3 1 1 Current rating and overcurrent protection All internal wiring used in the Pass distribution of primary power protected against over current were evaluated as an element of power supply certification 3 1 2 Protection against mechanical damage The wires are routed away Pass from sharp edges and parts which could damage insulation 3 1 3 Securing of internal wiring The wires are positioned in Pass such a manner that prevents excessive strain loosening of terminal connections and damage of conductor insulation 3 1 4 Insulation of conductors N A 3 1 5 Beads and ceramic insulators The equipment does not have N A any beads or similar insulators 3 1 6 Screws for electrical contact pressure The equipment does not have N A any screw type connections 3 1 7 Insulating materials in electrical connections No contact pressure through Pass insulating material 3 1 8 Self tapping and spaced thread screws Thread cutting or space thread N A screws are not used for electrical connections Machine screws only 3 1 9 Termination of conductors N A 10 N pull test N A 3 1 10 Sleeving on wiring Sleeving is not used as N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 20 of 45 Report Reference
4. N A N Annex N IMPULSE TEST GENERATORS see 2 10 3 4 6 2 2 1 7 3 2 and N A clause G 5 N 1 ITU T impulse test generators N A N 2 IEC 60065 impulse test generator N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 36 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict P Annex P NORMATIVE REFERENCES Pass Q Annex Q BIBLIOGRAPHY Pass R Annex R EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL N A PROGRAMMES R 1 Minimum separation distances for unpopulated N A coated printed boards see 2 10 6 R 2 Reduced clearances see 2 10 3 N A S Annex S PROCEDURE FOR IMPULSE TESTING see 6 2 2 3 N A S 1 Test equipment N A S 2 Test procedure N A S 3 Examples of waveforms during impulse testing N A T Annex T GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER see N A 1 1 2 U Annex U INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED N A INSULATION see 2 10 5 4 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 37 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 5 1 Object part No TABLE list of critical components Manufacturer trademark type model technical data Product Category CCN s
5. The test finger was unable to Pass contact bare hazardous parts Test with test pin aaa aaa The test pin was unable to Pass contact bare hazardous parts Test with test probe No TNV present N A 2 1 1 2 Battery compartments b NA 2 1 1 3 Access to ELV wiring Internal wiring in an ELV circuit N A is not user accessible Working voltage V minimum distance mm through insulation sese i 2 1 1 4 Access to hazardous voltage circuit wiring No internal wiring accessible to NA the user 2 1 1 5 Energy hazards eenn No energy hazard in operator Pass access area 2 1 1 6 Manual controls The equipment does not N A contain any knobs handles levers or the like 2 1 1 7 Discharge of capacitors in equipment N A Time constant s measured voltage V 2 1 2 Protection in service access areas No bare parts operating at N A HAZARDOUS VOLTAGES in a service access area 2 1 3 Protection in restricted access locations N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 11 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 2 SELV circuits Pass 2 2 1 General requirements The unit is s
6. No IT testing phase phase voltage V N A Class of equipment a Class III supplied by SELV Mass of equipment kg 8 4 kg Protection against ingress of water IP XO Possible test case verdicts test case does not apply to the test object N A test object does meet the requirement Pass test object does not meet the requirement Fail acceptable only if a corresponding less stringent national requirement is Pass Underwriters Laboratories Inc Issue Date 2007 07 09 Page 4 of 45 Report Reference E213998 A12 UL 1 General remarks see Enclosure refers to additional information appended to the Test Report see appended table refers to a table appended to the Test Report Throughout the Test Report a point is used as the decimal separator Underwriters Laboratories Inc Issue Date 2007 07 09 Page 5 of 45 Report Reference E213998 A12 UL 1 GENERAL PRODUCT INFORMATION CA1 0 Report Summary CA1 1 N A CB1 0 Product Description CB1 1 Electronic components mounted on PWB D A inverter and LCD panel and includes with one HDD two USB ports one RS232 port one RJ 45 port two 1394 ports one print port one DVI port an
7. 4 3 8 Lithium battery reverse current measurement test 19 Panel PC model W19B89T XXXX Motherboard model iBase Technology Inc MB890 RTC Normal 12Vdc Charging current is 0 1mA battery reverse current test RTC Short 12Vdc Charging current is 3 3mA battery reverse current test D10 1 2 RTC Short 12Vdc Charging current is 2 9mA battery reverse current test D10 2 3 RTC Short 12Vdc Charging current is 0 1mA battery reverse current test R273 5 3 1 5 3 8 2 ABNORMAL Underwriters Laboratories Inc Issue Date 2007 07 09 Page 43 of 45 Report Reference E213998 A12 UL 1 Clause Requirement Test Result Remark Verdict IEC 60950 1 OPERATION TESTS 19 Panel PC model W19B89T XXXX Adapter model LI SHIN 0225B12110 System fan Blocked 12Vdc 2hrs 5 48 NT NC CT Normal 29mins operation No hazardous Maximum Temp T1 coil 96 4 C Ambient 40 0 C CPU fan Stalled 12Vdc 2hrs 5 48 NT NC CT Normal 21mins operation No hazardous Maximum Temp T1 coil 90 7 C Ambient 40 0 C Ventilation openings Blocked 12Vdc 1hrs 5 48 NT NC CT Normal 44mins operation No hazardous Maximum Temp T1 coil 98 2 C Ambient 40 0 C 5 3 6 Overload of operator accessible connector test 19 Panel PC model W19B89T XXXX
8. Z ZA erei I i iwi SIR SIMAX sees XT 1 M dr 4 es d n e Geen H NOTE 1 COIL BS 2 CORE FIX BY KAPTON TAPE Zeen 3 CORE Bi EPOXY HIE 4 ERE 5 2 4 KAPTON TAPE LIDIO PAGE 10F6 BLING JEY ENTERPRISE CO LID DONG WAN GOANG BAO ELECTRONIC OO LTD E213998 A12 UL 1 Diagrams2 1653x2338x2 tiff 2 SPECIFICATION FOR APPROVAL CUSTOMER 381 BL e PART NUMBER LTL19010609B REV _ DESCRIPTION __EEL19X EMR__ DATE _ 09 11 2006 SCHEMATIC WINDNG_ SUMMARY WINDING SPECIFICATION a TERMINALNO WINGDING SPECIFICATION REMARK STAR FISH L 1 4 QUEWO10xds WE WEWOADx1S BREIT Pp155 006mm PSIPLP2 WA PREPARED BY EAR es PAGE 6 MAES QUE ELA 9 BIING JEY ENTERPRISE CO UID 3 o 8 8 To DONG WAN GOANG BAO ELECTRONIC CO E213998 A12 UL 1 Diagrams3 1653x2338x2 tiff Universal Microelectronics Co Ltd 8 SPECIFICATION 3 27Th R Taichung Industrial Park a a Taichung Taiwan R O C FOR APPROVAL Pra ui quM RAZ aka UM MODEL NO ISSUE NO USTA 9 COMMON MODE CHOKE E 22 UT34463 CUSTOMER CUSTOMERS P N DATE UM REV SHEET ERE ES LK W9R801006U 16 JUN 2006 BO 20F3 CONSTRUCTION TAP 21s 0 1mm 2 SFHW 0
9. May be provided in other languages upon request from the manufacturer 1 7 13 Durability The marking s withstood the Pass required test 1 7 14 Removable parts No marking is located on a Pass removable part s 1 7 15 Replaceable batteries The required warning is in the Pass service manual 110 88 9 3220 e tede ts Only English language reviewed May be provided in other languages upon request from the manufacturer 1 7 16 Operator access with a tool No operator access areas Pass require the use of a tool 1 7 17 Equipment for restricted access locations Equipment not intended for N A installation in a RESTRICTED ACCESS LOCATION Underwriters Laboratories Inc Issue Date 2007 07 09 Page 10 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 PROTECTION FROM HAZARDS Pass 2 1 Protection from electric shock and energy hazards Pass 2 1 1 Protection in operator access areas Pass 2 1 1 1 Access to energized parts No operator access parts are Pass energized parts Test by inspection a a Operator can not contact with Pass any parts with only basic insulation to ELV or hazardous voltage Test with test finger a
10. N A 1 5 5 Detachable external interconnecting cables 3 05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable N A 1 5 5 Building wiring and cable for use in ducts plenums There are no any Telephone N A and other air handling space subject to special line and extension cords requirements and excluded from scope 1 5 5 Telephone line and extension cords and the like comply with UL 1863 and CSA C22 2 No 233 N A 1 6 1 2 Equipment intended for connection to a d c power mains distribution system is subject to special N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 3 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict circuit classification requirements e g TNV 2 1 6 1 2 1 7 Earthing of d c powered equipment provided Lamp replacement information indicated on lampholder in operator access area N A N A 1 7 1 Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor N A 1 7 1 1 7 6 Equipment voltage rating not higher than rating of the plug except under special conditions Special fuse replacement marking for operator accessible fuses N A N A 1 7 7 Identification of termina
11. Required Marks of Conformity Supplement ID Pass 01 Switching adapter Li Shin International 0227B12110 I p 100 240V 2 0A 50 60Hz QQGQ UL Enterprise Corp O p 12V 9 17A 02 Interconneciing Various Various Min 80 degree C 30V max AVLV2 UL Cable optional 3 05 m long jacketed VW 1 or FT 1 03 Label Various Various Min 50 degree C if maximum PGDQ2 or PGJl2 UL surface temperature not specified 04 Wiring internal Various Various FEP PTFE PVC TFE AVLV2 UL 3 03 secondary ELV SELV neoprene polyimide or marked circuits VW 1 jacketed min 30V 80 degree C 05 Connectors and Copper alloy pins housed in QMFZ2 ECBT2 UL Receptacles secondary bodies of plastic rated V 2 min RTRT2 DUXR2 ELV SELV circuits 06 Insulating Various Various FEP PTFE PVC TFE UZFT2 YDPU2 UL 3 03 Tubing Sleeving neoprene polyimide or marked YDTU2 VW 1 105 degree C 300V 07 Enclosure Metal min thickness 0 95 mm 3 01 min Total overall 480 by 330 by 91 mm max 08 LCD Panel Various Various 19 TFT Type 3 01 09 Speaker x2 8 ohm 3 0W max 3 03 10 DC Fan for Evercool Thermal EC4020L12BA 12Vdc 0 06A max 4 97 CFM GPWV2 UL System Co Ltd min 10 01 DC Fan for Minebea Matsushita 1604KL 04W B49 12Vdc 0 10A max 4 95 CFM GPWV2 UL CPU Motor Corp min 11 HDD Various Various 5V 12V 1 5A 2 0A max NWGQ2 UL 12 D A Inverter Taiwan Power TI
12. TURNS I 265Ts REF S8mHH20 15 amp 75 105mH 13 70 MAX l 8 mH 20 15 75 105mH 13 7 0 MAX PAGE 10F3 ERARA BLING JEY ENTERPRISE o Am R DONG WAN GOANG BAD ELECTRONIC D LD Issue Date 2007 07 09 Page 1 of 5 Report Reference E213998 A12 UL 1 Enclosure Schematics PWB Supplement Id Description 5 01 PCB layout of inverter Taiwan Power Conversion Inc TI1704WM 03 Underwriters Laboratories Inc Mm rv aa a IRN SOE St A Dy anui i A de wd Wed Sep 20 10 20 16 2006 Untitled CAM350 PRO V 7 0 TJ 120401 03 Top Overlay Issue Date 2007 07 09 Page 1 of 4 Report Reference E213998 A12 UL 1 Enclosure Manuals Supplement Id Description 6 01 Installation Manual Underwriters Laboratories Inc E213998 A12 UL 1 Manuals1 1700x2200x2 tiff Winmate Panel PC Mounting User s Guide Mounting Guide 5mm Panel mount Panel PC Panelis aligned with the same height of the front of open frame metal housing Touch Glass is higher than Open frame metal housing Customers can fix our Panel PC with their fixture max 12mm VESA mount holes are also available for mounting from back side Touch 3 6 mm 7 Panel o Cut out 7 dimension 1 3 7 Front bezel Sram P scht Medak fatme Mounting Kits v Adhesive Transfer Tepes Custtene g furs 27 Customers fixture y max Timm Z Emm
13. pin12 13 22 Open circuit 23 25 voltage 3 39Vdc Maximum available current 0mA supplementary information Comments Key COMPONENT FAILURE TEST ABNORMAL OPERATION TEST TRANSFORMER ABNORMAL OPERATION TEST P Internal protection operated list component CT Constant temperatures were obtained CD Components damaged list damaged components NB No indication of dielectric breakdown NT Tissue paper remained intact NC Cheesecloth remained intact OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST B Circuit measures less than 12 5 mA C Circuit measures 0 Volts Underwriters Laboratories Inc
14. 6 3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection N A 6 3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable N A 6 4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures Fig 6C N A 6 4 Where 26 AWG line cord required by Fig 6C either the cord is provided with the equipment or described in the safety instructions N A 6 5 Acoustic pressure from an ear piece less than 136 dBA for short duration disturbances and less than 125 dBA for handsets 118 dBA for headsets and 121 dBA for insert earphones for long duration disturbances N A Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC N A M 2 lonizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act REDR C1370 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations N A N A M 4 Special requirements for message waiting and similar telecommunications s
15. General requirements Pass 2 4 2 Limit values Inverter 11 704WM 03 manufactured by Taiwan Power Conversion Inc Current limit value is 22 18 mA when min measured frequency is 47 4 kHz Pass Frequency Hz Inverter TI1704WM 03 manufactured by Taiwan Power Conversion Inc Min measured 47 4 kHz from CON 2 pin2 to Earth at R15 short Measured current m Inverter TI1704WM 03 manufactured by Taiwan Power Conversion Inc Max measured 12 5 mA from CON pin2 to Earth when R24 short Measured voltage NI I 1 Method Part Inverter TI1704WM 03 manufactured by Taiwan Power Conversion Inc Max measured 25 0 Vpk from CON 2 pin2 to Earth when R24 short 2 Method Part II CON pint to pin2 normal consition Max measured 1180 Vpk Measured capacitance mF 0 1uF 118uC 2 4 3 Connection of limited current circuits to other circuits Limited current circuit meets the limits of 2 4 2 under normal conditions and under single component or insulation faults in interconnected circuits Pass Underwriters Laboratories Inc Issue Date 2007 07 09 Page 13 of 45 Report Reference E213998 A12 UL 1 Clause IEC 60950 1 Requirement Test Result Remark Verdict 2 5 Limited power sources Pass Inherently limited output N A Impedance limited output
16. for inverter Universal Microelectronics Co Ltd 4 02 Alternate T1 T2 spec for inverter Biing Jey Enterprise Co Ltd 4 03 CE1 CE2 spec for inverter Universal Microelectronics Co Ltd 4 04 Alternate CE1 CE2 spec for inverter Biing Jey Enterprise Co Ltd Underwriters Laboratories Inc E213998 A12 UL 1 Diagrams1 1653x2338x2 tiff g SPECIFICATION an FOR APPROVAL UM MODEL NO UT35G74 TRANSFORMER Universal Microelectronics Co Lid 3 27Th Rd Taichung Industrial Park Taichung Taiwan R O C TEL 886 4 23590096 PAX 886 4 2359 0129 httpz Aeww umec web com E mail business umec com tw ISSUE NO USTA 95437 UM REV SHEET CUSTOMER CUSTOMER S P N DATE POZE LTL19010609U 15 SEP 2006 AO 2 OF 2 DIMENSION amp SCHEMATIC 7 gt lt 1 e D 1mm 15 i gt 2375 3 A 7 Hd Fu E 4 0 06mm L 29 9 0 2 3 7 1500Ts SE 0 1mm 15 10 34 1 0 3 A 23Ts EPOXY LE 21 0 MAX 7 N L ho H N f o D O m H f x I m 1 2 7 CD 1 0 6 0 4 KAPTON TAPE 1T UNIT mm DRAWN BY Liao APPROVED BY Andy Tseng CHECKED BY E10 011 C E213998 A12 UL 1 Diagrams2 1653x2338x2 tiff SPECIFICATION FOR APPROVAL CUSTOMER g 28 H PART NUMBER LTL19010609B REV _ DESCRIPTION EELI9X FMR DATE 09 11 2006 A DIMENSION UNIT mm Zt A EI AT
17. 5 Open circuit voltage 4 89Vdc Maximum available current 0mA PS2 Mouse Overload 12Vdc C pin2 3 6 Open circuit vollage 0Vdc Maximum available current 0mA PS2 Keybo Overload 12Vdc 1hrs NB NC NT ard pin10 Open circuit voltage 4 99Vdc Maximum available current 1800mA PS2 Keybo Overload 12Vdc 1sec B ard pin7 11 Open circuit voltage 4 89Vdc Maximum available current 0mA PS2 Keybo Overload 12Vdc C ard pin8 9 Open circuit voltage 0Vdc 12 Maximum available current 0mA RJ45 Overload 12Vdc C pin1 8 Open circuit vollage 0Vdc Maximum available current 0mA RS232 Overload 12Vdc C pin1 9 Open circuit voltage 0Vdc Underwriters Laboratories Inc Issue Date 2007 07 09 Page 45 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict Maximum available current 0mA DVI Overload 12Vdc 1sec B pin1 2 4 5 7 Open circuit 8 12 13 20 voltage 1 21Vdc 21 23 24 Maximum available current 0mA DVI Overload 12Vdc 1sec B pin11 17 18 Open circuit 19 voltage 5 01Vdc Maximum available current 0mA DVI Overload 12Vdc C pin3 6 9 10 Open circuit vollage 0Vdc 14 15 16 2 Maximum available current 2 0mA Print port Overload 12Vdc 1sec B pini 4 24 Open circuit voltage 4 64Vdc Maximum available current 0mA Print port Overload 12Vdc 1sec B
18. A Ferrite Overall 16 96 by 13 by Inverter Transformer 6 47 mm 12 C 02 Bobbin for D A Various Various Liquid Crystal Polymer L C P QMFZ2 UL Inverter Transformer rated V 2 min min thickness 0 3 mm or Phenolic min 0 71 mm 12 C 03 Wire for D A Various Various Copper magnet wire 105 OBMW2 UL Inverter Transformer degree C min 12 D Transformer CE1 Biing Jey Enterprise LKW9R801006B 105 degree C 4 04 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 39 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict CE2 Alternate Co Ltd 12 D 01 Core for D A Ferrite Overall 16 96 by 13 by Inverter Transformer 6 47 mm 12 D 02 Bobbin for D A Various Various Liquid Crystal Polymer L C P QMFZ2 UL Inverter Transformer rated V 2 min min thickness 0 3 mm or Phenolic min 0 71 mm 12 D 03 Wire for D A Various Various Copper magnet wire 105 OBMW2 UL Inverter Transformer degree C min 13 Capacity C15 C17 Various Various 10pF 3KV 14 Mother board iBase Technology MB890 3 05 Inc 14 01 RTC Battery Sony Energy Devices CR2032 3V 220mAh max abnormal BBCV2 UL Corporation charging current 12mA 14 02 USB Protective Richtek Technology RT9701PBL 2 2 6 Vdc 2 2A QVGS2 UL Device Q47 Q11 Corp 14 03 PTC Polyswitch
19. Class III equipment N A 3 3 2 Connection of non detachable power supply cords N A 3 3 3 Screw terminals N A 3 3 4 Conductor sizes to be connected N A Ratedcurent A cord cabletype cross sectional le agred MIM el ee rici d t c ERAS 3 3 5 Wiring terminal sizes N A Rated current A type and nominal thread diameter MM u 3 3 6 Wiring terminals design N A 337 Grouping of wiring terminais NA 3 3 8 Stranded wire N A 3 4 Disconnection from the mains supply N A 3 4 1 General requirement Class IIl equipment N A 3 4 2 Disconnect devices N A 3 4 3 Permanently connected equipment N A 3 4 4 Parts which remain energized N A 3 4 5 Switches in flexible cords N A 3 4 6 Single phase equipment and d c equipment N A 347 Three phase equipment NA 348 Switches as disconnect devices NA 3 4 9 Plugs as disconnect devices N A 3 4 10 Interconnected equipment N A 3 4 11 Multiple power sources N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 22 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 3 5 Interconnection of equipment Pass 3 5 1 General requirements Pass 3 5 2 Types of interconnection circuits Interconnection circuits are Pass SELV CIRCUITS 3 5 3 ELV circuits as interconnection circ
20. E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 3 2 Connection to an a c mains supply or a d c mains supply N A 3 2 1 Means of connection No direct connection to mains N A 3 2 1 1 Connection to an a c mains supply N A 3 2 1 2 Connection to a d c mains supply N A 3 2 2 Multiple supply connections N A 3 2 3 Permanently connected equipment N A Number of conductors diameter mm of cable and 60100 LA SEE tee nid idee sss 3 2 4 Appliance inlets N A 3 2 5 Power supply cords N A 3 2 5 1 AC power supply cords N A TEV DG id t deii cete eere teet Rated current A cross sectional area mm AWG i ipd edt dod a tiens 3 2 5 2 DC power supply cords N A 3 2 6 Cord anchorages and strain relief N A Mass of equipment kg pull N Longitudinal displacement mm 3 2 7 Protection against mechanical damage N A 3 2 8 Cord guards N A D mm test mass g Radius of curvature of cord mm 3 2 9 Supply wiring space N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 21 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 3 3 Wiring terminals for connection of external conductors N A 3 3 1 Wiring terminals
21. Marking or Instruction Details Clause 1 7 1 Power rating Ratings voltage frequency dc current Ratings Power rating Listee s or Recognized company s name Trade Name Trademark or File Company Number identification Power rating Model Number Model 1 7 8 3 Symbols n d Set Stand by switch Stand by to be indicated by 60417 2 IEC 5009 1 7 15 Replaceable CAUTION Risk of Explosion if Battery is replaced by an Incorrect Type batteries Dispose of Used Batteries According to the Instructions Underwriters Laboratories Inc Issue Date 2007 07 09 Page 2 of 45 Report Reference E213998 A12 UL 1 BD1 0 Production Line Testing Requirements BD1 1 Electric Strength Test Special Constructions Refer to Generic Inspection Instructions Part AC for further information Test Potential V Test Model Component Removable Parts Test probe location rms Vdc Time s N A BD1 2 Earthing Continuity Test Exemptions This test is not required for the following models BD1 3 Electric Strength Test Exemptions This test is not required for the following models BD1 4 Electric Strength Test Component Exemptions The following solid state components may disconnected from the remainder of the circuitry during the performance of this test BE1 0 Sample and Test Specifics for Follow Up Tests at UL BE1 1 Test Model Component Material Test Sample s Specifics N A Underwriter
22. Polytronics SMD1812P110TF 8V Ih 1 1A It 2 2 CA 3 XGPU2 UL for PS 2 ports use F3 Technology Corp 14 04 PTC Polyswitch Polytronics SMD1812P260TF 8V Ih 2 6A It 5 2 CA 3 XGPU2 UL for 1394 ports use F4 Technology Corp F5 15 All PWBs Various Various V 1 min 105 degree C ZPMV2 UL 3 03 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 40 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict TABLE electrical data in normal conditions fuse I rated A U V P W I mA fuse mA condition status 9 17 12Vdc 65 76 5480 Maximum normal load supplementary information Maximum normal load was defined as follows Reading and writing in HDD playing music and each USB ports loaded 2 5W with Max contrast and brightness display normally 2 10 3 and TABLE clearance and creepage distance measurements clearance cl and creepage required cl required distance dcr at of mm dcr mm supplementary information All circuits are SELV only functional insulation required 2 10 5 TABLE distance through insulation measurements N A distance through insulation di at of Up test voltage V required di di V mm mm supplementary information 4 5 TABLE temperature rise measurements Pas
23. Sample 2 burning time s Sample 3 burning time s i Underwriters Laboratories Inc Issue Date 2007 07 09 Page 31 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict A 2 Flammability test for fire enclosures of movable equipment having a total N A mass not exceeding 18 kg and for material and components located inside fire enclosures see 4 7 3 2 and 4 7 3 4 A 2 1 Samples material Wall thickness MM eee eee eee eee eee A 2 2 Conditioning of samples N A A 2 3 Mounting of samples N A A 2 4 Test flame N A A 2 5 Test procedure N A A 2 6 Compliance criteria N A Sample 1 burning time s Sample 2 burning time s Sample 3 burning time s A 2 7 Alternative test acc to IEC 60695 2 2 cl 4 8 N A Sample 1 burning time s Sample 2 burning time s i Sample 3 burning time s A 3 Hot flaming oil test see 4 6 2 N A A 3 1 Mounting of samples N A A 3 2 Test procedure N A A 3 3 Compliance criterion N A Underwriters Laboratories Inc
24. See Table 1 5 1 for PTC specifications For PS2 and 1394 ports 1 PS2 Approved PTC Current Limiters Device F3 provided type SMD1812P110TF manufactured by Polytronics Technology Corp 2 1394 Approved PTC Current Limiters Device F4 F5 provided type SMD1812P260TF manufactured by Polytronics Technology Corp Pass Overcurrent protective device limited output Regulating network limited output under normal operating and single fault condition For USB port Approved Protectors Low Voltage Solid State Q11 Q47 provided type RT9701PBL manufactured by Richtek Technology Corp Pass N A Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition N A Output voltage V output current A apparent power MA iiss USB1 and USB2 port Uoc 4 99 V Isc 1 4 max VA 6 41 VA max PS 2 Mouse and Keyboard port Uoc 4 99 V Isc 2 1 max VA 8 67 VA max 1394 CNB and CN8 port Uoc 11 96V Isc 3 3 max VA 35 60 VA max Current rating of overcurrent protective device A protective current 2 2A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 14 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 6 Provisions for earthing an
25. bort bezel Pane Mount i birm front beret i Put Panel PC on the Bette ber iere A from ine front vath the sites of i Wa front bezel shawn on the outside i ide View E213998 A12 UL 1 Manuals1 1700x2200x2 tiff 2 Winmate Panel PC Mounting User s Guide Use provided mounting kis in fix the Panel PC and he others fitum H tear View i i i PANEL PC PM 5mm PANEL PC size Mounting Kits pes GA l 4 65 E213998 A12 UL 1 Manuals1 1700220012 tiff 3 Winmate Panel PC Mounting User s Guide VESA mount Panel PC Fix the Panel PC with four screws standard VESA and fasten to the wall with other four screws A 100 x 100 mm 75x 75mm AT eus 7 VESA mount Panel PC Panel PC size VESA Mount Dimension 6 4 75 x 75 mm 6 5 75 x 75 mm 8 4 75 x 75 mm 10 4 75 x 75 mm 12 1 75 x 75 mm 15 75 x 75 mm 100 x 100 mm 17 75 x 75 mm 100 x 100 mm 19 75 x 75 mm 100 x 100 mm Issue Date 2007 07 09 Page 1 of 10 Report Reference E213998 A12 UL 1 Enclosure National Differences USA Canada Underwriters Laboratories Inc Issue Date 2007 07 09 Page 2 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict USA Canada Differences to IEC 60950 1 2001 First Edition Equipment
26. interchangeable plugs sockets 4 3 6 Direct plug in equipment Not direct plug in equipment N A Dimensions mm of mains plug for direct plug in Not direct plug in unit N A Torque and pull test of mains plug for direct oe in N A torque Nm pull NN 4 3 7 Heating elements in earthed equipment The equipment does not have N A any heating elements 4 3 8 Batteries Measured Reverse Current Pass please see table 5 3 for detail 4 3 9 Oil and grease The insulation of the internal N A wiring is not exposed to oil grease etc 4 3 10 Dust powders liquids and gases The equipment does not N A produce dust or employ powders liquids or gases 4 3 11 Containers for liquids or gases The equipment does not N A contain liquids 4 3 12 Flammable liquids eee eee ee The equipment does not use N A any flammable liquids Quantity of liquid UI N A Flash poli EEN N A 4 3 13 Radiation type of radiation The equipment does not N A generate ionizing radiation or contain flammable liquids or gases Underwriters Laboratories Inc Issue Date 2007 07 09 Page 24 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 3 13 1 General N A 4 3 13 2 lonizing radiation N A Measured radiation pA kg Measured high voltage
27. kV Measured focus voltage kV CR markings at ence eed AA 4 3 13 3 Effect of ultraviolet UV radiation on materials N A Part property retention after test flammability N A classification u Uu UN au sae 4 3 13 4 Human exposure to ultraviolet UV radiation N A 4 3 13 5 Laser including LEDs N A Laser class i ies ode asic 4 3 13 6 Other types ett lee i N A 4 4 Protection against hazardous moving parts N A 4 4 1 General N A 4 4 2 Protection in operator access areas N A 4 4 3 Protection in restricted access locations N A 4 4 4 Protection in service access areas N A 4 5 Thermal requirements Pass 4 5 1 Maximum temperatures The equipment and its Pass component parts did not attain excessive temperatures during normal operation Normal load condition per Annex L Operated in the most Pass unfavorable way of operation given in the operating instructions until steady conditions established see appended table 4 5 4 5 2 Resistance to abnormal heat N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 25 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 6 Openings in enclosures Pass 4 6 1 Top and side openings Openings do not exceed 5 mm Pass in any dimension Dimensions mm 1 Topside Two opening are
28. routine testing N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 4 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict In the event of a single fault the limits of 2 2 3 apply to SELV circuits and accessible conductive parts N A 2 5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC or for a Limited Power Source not interchangeable with devices of higher ratings if operator replaceable N A 2 6 Equipment having receptacles for output a c power connectors generated from an internal separately derived source have the earthed grounded circuit conductor suitably bonded to earth N A 2 6 3 3 For Pluggable Equipment Type A if neither a or b are applicable the current rating of the circuit is taken as 20 A N A 2 6 3 4 Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit N A 2 6 3 4 Protective bonding conductors and their terminals of non standard constructions e g PWB traces evaluated to limited short circuit test of CSA C22 2 No 0 4 N A 2 6 4 1 Field wiring terminals for earthing conductors suitable for wire sizes gauge used in US and Canada N A 2 7 1 Data for selection of special external bran
29. 1704WM 03 I P 13 2Vdc max 2 5A O P 3 07 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 38 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict Conversion Inc 760Vrms max 8 0mArms max 12 A Transformer T1 Universal LKW9R801006U 105 degree C 4 01 T2 Microelectronics Co Ltd 12 A 01 Core for D A Ferrite Overall 27 7 by 20 by Inverter Transformer 7 85 mm 12 A 02 Bobbin for D A Various Various Liquid Crystal Polymer L C P QMFZ2 UL Inverter Transformer rated V 2 min min thickness 0 3 mm or Phenolic min 0 71 mm 12 A 03 Wire for D A Various Various Copper magnet wire 180 OBMW2 UL Inverter Transformer degree C min 12 B Transformer T1 Biing Jey Enterprise LTL19010609B 105 degree C 4 02 T2 alternate Co Ltd 12 B 01 Core for D A Ferrite Overall 27 7 by 20 by Inverter Transformer 7 85 mm 12 B 02 Bobbin for D A Various Various Liquid Crystal Polymer L C P QMFZ2 UL CUL Inverter Transformer rated V 2 min min thickness 0 3 mm or Phenolic min 0 71 mm 12 B 03 Wire for D A Various Various Copper magnet wire 105 OBMW2 UL Inverter Transformer degree C min 12 C Transformer CE1 Universal LTL19010609U 105 degreeC 4 03 CE2 Microelectronics Co Ltd 12 C 01 Core for D
30. 1mm 2 SFHW 265Ts PIN 1 2 265Ts PIN 6 5 SCHEMATIC 10 O 6 60 1mm 2 SFHW 265Ts 80 1mm 2 SFHW 265Ts APPROVED BY Char les Huang CHECKED BY Harris E213998 A12 UL 1 Diagrams3 1653x2338x2 tiff 2 Universal Microelectronics Co Ltd SPECIFICATION 3 27Th Rd Taichung Industrial Park Taichung Taiwan R O C TEL 886 4 23590096 FAX 886 4 2359 0129 aa F OR AP PROVAL http www umec web com E mail business umec com tw ISSUE NO USTA 95289 UM MODEL NO UT34463 CUSTOMER SGP COMMON MODE CHOKE i CUSTOMER S P N DATE LK W9R801006U 16 JUN 2006 DIMENSIONS EPOXY Marking LE W9R801006U A A DUR Be a 16 5 MIN 6 2 0 5 3 8 0 5 9 MAX Do 19 2 0 3 EPOXY APPROVED BY Charles Huang CHECKED BY Liao E10 011 C E213998 A12 UL 1 Diagrams4 1653x2338x2 tiff SPECIFICATION FOR APPROVAL CUSTOMER k E Bl j _ PART NUMBER LK W9R801006B REV __ DESCRIPTION UUS 0 B EO LINE FILTER COIL DATE 09 19 2006 Timm A DIMENSION UNI JB SCHEMATIC i 9 iC ELECTRICAL CHARACTER TEST CONDITION AT 1KHz 025Vrms 5 RELATIVE HUMIDITY 56420 TEMPERATURE 25 C TEST METER CH 102 CHS02AC
31. 2 Humidity conditioning N A Humidity Jo esasa Temperature CC 2 9 3 Grade of insulation Function insulation Pass Underwriters Laboratories Inc Issue Date 2007 07 09 Page 17 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 10 Clearances creepage distances and distances through insulation Pass 2 10 1 General Pollution degree 2 applicable Pass 2 10 2 Determination of working voltage Class Ill equipment N A 2 10 3 Clearances see appended table 2 10 3 Pass and 2 10 4 2 10 3 1 General See below Pass 2 10 3 2 Clearances in primary circuit N A 2 10 3 3 Clearances in secondary circuits see appended table 2 10 3 Pass and 2 10 4 2 10 3 4 Measurement of transient voltage levels N A 2 10 4 Creepage distances see appended table 2 10 3 Pass and 2 10 4 ERR Material group Illb 100 lt CTI lt 175 2 10 5 Solid insulation N A 2 10 5 1 Minimum distance through insulation N A 2 10 5 2 Thin sheet material N A Number of layers PCS ss I Electric strength test 2 10 5 3 Printed boards PWB is not used as reinforced N A or supplementary insulation Distance through insulation N A Electric strength test for thin sheet insulating material AAA AAA Num
32. 4 3 12 under all conditions of servicing marked to indicate the presence of radiation where readily visible N A 4 3 13 5 Requirements contained in the applicable national codes and regulations apply to lasers 21 CFR 1040 Underwriters Laboratories Inc N A Issue Date 2007 07 09 Page 8 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict and REDR C1370 4 7 Automated information storage equipment intended N A to contain more than 0 76 m of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system 4 7 3 1 Equipment for use in environmental air space other N A than ducts or plenums provided with metal enclosure or with non metallic enclosure having adequate fire resistance and low smoke producing characteristics Low smoke producing characteristics evaluated according to UL 2043 Equipment for installation in space used for environmental air as described in Sec 300 22 c of the NEC provided with instructions indicating suitability for installation in such locations 4 7 3 1 Flame spread rating for external surface of N A combustible material with exposed area greater than 0 93 m or a single dimension greater than 1 8 m 50 or less for computer room applications or 200 or less for other applications 4 7 3 4 Wire marked VW 1 or FT 1 considered Internal wiring is UL Pass equiva
33. A Max allowed touch current MA Measured protective conductor current mA Max allowed protective conductor current mA 5 1 7 Equipment with touch current exceeding 3 5 mA N A 5 1 8 Touch currents to and from telecommunication N A networks and cable distribution systems and from telecommunication networks 5 1 8 1 Limitation of the touch current to a N A telecommunication network and a cable distribution system Test voltage V ute hende te Measured touch current mA Max allowed touch current MA 5 1 8 2 Summation of touch currents from N A telecommunication networks 5 2 Electric strength N A 5 2 1 General Class III unit N A 5 2 2 Test procedure N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 28 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 5 3 Abnormal operating and fault conditions Pass 5 3 1 Protection against overload and abnormal See below Pass operation 5 3 2 Motors N A 5 3 3 Transformers Evaluated as part of power N A supply 5 3 4 Functional insulation
34. A12 UL 1 SPECIFIC INSPECTION CRITERIA BA1 0 Special Instructions to UL Representative BA1 1 N A BB1 0 Supporting Documentation BB1 1 The following documents located at the beginning of this Procedure supplement the requirements of this Test Report A Authorization The Authorization page may include additional Factory Identification Code markings B Generic Inspection Instructions i Part AC details important information which may be applicable to products covered by this Procedure Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report li Part AE details any requirements which may be applicable to all products covered by this Procedure Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report iii Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products Products are permitted to bear only the Certification Mark s corresponding to the countries for which it is certified as indicated in each Test Report BC1 0 Markings and instructions BC1 1 The following markings and instructions are provided as indicated BC1 2 All clause references are from UL 60950 1 1st Edition 2006 07 07 Information Technology Equipment Safety Part 1 General Requirements Standard Clause Title
35. Functional insulation complies Pass with the requirements a b or c 5 3 5 Electromechanical components The equipment does not have N A any electromechanical components in the secondary 5 3 6 Simulation of faults See appended table 5 3 Pass 5 3 7 Unattended equipment Equipment is not intended for N A unattended use 5 3 8 Compliance criteria for abnormal operating and No fire emission of molten Pass fault conditions metal or deformation was noted during the tests 6 CONNECTION TO TELECOMMUNICATION NETWORKS N A 6 1 Protection of telecommunication network service persons and users of other N A equipment connected to the network from hazards in the equipment 6 1 1 Protection from hazardous voltages N A 6 1 2 Separation of the telecommunication network from earth N A 6 1 2 1 Requirements N A Test voltage V ien Current in the test circuit mA i 6 1 2 2 ele EE N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 29 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 6 2 Protection of equipment users from overvoltages on telecommunication N A networks 6 2 1 Separation requirements N A 6 2 2 Electric strength test procedure N A 6 2 2 1 Impulse test N A 6 2 2 2 Steady state test N A 6 2 2 3 Compliance criteria N A 6 3 Prot
36. Issue Date 2007 07 09 Page 1 of 2 Report Reference E213998 A12 UL 1 COVER PAGE FOR TEST REPORT Product Category Product Category CCN Test Procedure Product Model Type Reference Rating s Standards Applicant Name and Address Information Technology Equipment Including Electrical Business Equipment NWGQ NWGQ7 Listing 19 Panel PC W19B89T XXXX X can be 0 9 A Z or blank 12Vdc 9 17A UL 60950 1 1st Edition 2006 07 07 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 03 1st Edition 2006 07 Information Technology Equipment Safety Part 1 General Requirements WINMATE COMMUNICATION INC 9TH FL 111 6 HSING TE RD SUN CHUNG TAIPEI HSIEN 241 TAIWAN This Report includes the following parts in addition to this cover page Specific Inspection Criteria Specific Technical Criteria Clause Verdicts Critical Components Test Results National Differences Enclosures NOOR WD Copyright 2007 Issue Date 2007 07 09 Page 2 of 2 Report Reference E213998 A12 UL 1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow Up Service under the indicated Test Procedure The manuf
37. Motherboard model iBase Technology Inc MB890 USB1 CN6 Pini Overload 12Vdc 1hrs NB NC NT Open circuit voliage 4 99Vdc Maximum available current 1100mA USB1 CN6 pin2 4 Overload 12Vdc C Open circuit vollage 0Vdc Maximum available current 0mA USB2 CN6 pin5 USB2 CN6 pin6 8 Overload Overload 12Vdc 12Vdc 1hrs NB NC NT Open circuit voltage 4 99Vdc Maximum available current 1100mA C Open circuit vollage 0Vdc Maximum available current 0mA 1394 port CN5 pin1 Overload 12Vdc 1hrs NB NC NT Open circuit voltage 11 96Vdc Maximum available current Underwriters Laboratories Inc Issue Date 2007 07 09 Page 44 of 45 Report Reference E213998 A12 UL 1 Clause Requirement Test Result Remark Verdict IEC 60950 1 3000mA 1394 port Overload 12Vdc C CN5 Open circuit vollage 0Vdc Pin2 6 Maximum available current 0mA 1394 port Overload 12Vdc 1hrs NB NC NT CN8 Open circuit Pin1 voltage 11 96Vdc Maximum available current 3000mA 1394 port Overload 12Vdc C CN8 Open circuit vollage 0Vdc Pin2 6 Maximum available current 0mA PS2 Mouse Overload 12Vdc 1hrs NB NC NT pin4 Open circuit voltage 4 99Vdc Maximum available current 1800mA PS2 M Overload 12Vdc 1sec B ouse pin1
38. N A provided 1 7 6 Fuse identification a Evaluated as an element of N A power supply certification 1 7 7 Wiring terminals N A 1 7 7 1 Protective earthing and bonding terminals N A 1 7 7 2 Terminal for a c mains supply conductors N A 1 7 7 3 Terminals for d c mains supply conductors N A 1 7 8 Controls and indicators See below Pass 1 7 8 1 Identification location and marking The function of controls Pass affecting safety is obvious regardless of language 1 7 8 2 CABUS Hoes xe tette debut iati niei JA green LED is illuminated Pass Underwriters Laboratories Inc Issue Date 2007 07 09 Page 9 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict when the unit is operating 1 7 8 3 Symbols according to IEC 60417 The stand by switch is marked Pass with the correct symbol 60417 1 IEC 5009 1 7 8 4 Markings using figures Figures are not used for N A indicating different positions of controls 1 7 9 Isolation of multiple power sources N A 1 7 10 IT power distribution systems N A 1 7 11 Thermostats and other regulating devices No thermostats or similar N A regulating devices 1 7 12 Language EE Reviewed only English markings instructions
39. Part 1 Standard General Requirements CSA C22 2 No 60950 1 03 1st Edition 2006 07 Information Technology Equipment Safety Part 1 General Requirements IEC 60950 1 2001 First Edition CCNs NWGQ NWGQ7 Product 19 Panel PC Models W19B89T XXXX Pl CAP COMPASS CTDP O TEP TPTDP O uL O wTDP TheWTDP test facility had the environment and capabilities necessary to perform the tests Universal Standard Services Inc Test Location Name Address 8F 1 No 266 Sec 1 Wen Hua 2nd Road Lin Kou Shiang 244 Taipei Country Taiwan Last CIP Assessment Date 2006 8 25 Sign n L Witness Sign Print Andy Cheng for WIDE Print Lab Hours Lab Submittai Date Lab Due Date Sign sig Print Reviewer IPrint Ext Ext Responsible Engineer Notes to Lab Log Number Log In Date s Log Out Date Log Out Reason Tests complete Test failure d u sam el d Reason for Lab Extension Lab Sign Supervisor Print Sign Reviewer Print Date Responsible Engineer Form Copyright 2005 Underwriters Laboratories Inc Created by ULtraLink on 16 May 07 Only those products bearing the UL Mark should be considered as being covered by UL Issue Date 2007 07 09 Page 1 of 9 Report Reference E213998 A12 UL 1 Enclosure Photographs Supplement Id Description 3 01 Top view 3 02 Rear view 3 03 Internal view 3 04 Connector view 3 05 Top view of Mother Boar
40. Signature Date CONSTRUCTION COMPLIANCE REVIEW RECORD Completed Construction PF Compliance Review was Stephen Ho d ji e gaiii Reviewed and accepted by Qualified Reviewer Printed Name Signature SAMPLE IDENTIFICATION Sample Card Date Received Sample Manufacturer Product Identification and Ratings See Datasheet The following additional information is required when using client s or rented equipment or when a UL ID Number for an instrument number is not used The Inst ID below corresponds to the Inst ID above Inst ID Make Model Serial Number Asset No a KK CONSTRUCTION COMPLIANCE REVIEW The sample was reviewed for compliance with the construction requirements in the standard s indicated below and a complete record including measurements to support compliance with those requirements is detailed in Report Reference Number E213998 A12 D I CSA C22 2 No 60950 1 03 1st Ed 2003 11 X UL60950 1 1st Ed 2006 07 07 D UL60950 1 1st Ed 2006 07 07 CSA C22 2 No 60950 1 03 1st Ed 2003 11 IEC 60950 1 2001 First Edition Standard s Page 1 of 1 Total Page e File E213998 Project 07CA25154 Elite DARE PI DATA PACKAGE INFORMATION SHEET Winmate Communication Inc 9Th FI 111 6 Hsing Te Rd Sun Chung City Taipei Hsien 241 Taiwan Applicant Name Address UL 60950 1 1st Edition 2006 07 07 Information Technology Equipment Safety
41. a Cover area is 15 6 by 27 4 mm max each circle opening is 3 4 mm max 2 Rear side Cover area is 60 65 by 60 65 mm max each circle opening is 4 2 mm max 3 Opening for DC Fan Cover area is 39 by 39 mm max each slot opening is 4 05 by 12 3 mm max 4 Mounting Holes See Manuals 6 01 for details 4 6 2 Bottoms of fire enclosures No openings Pass Construction of the bottom See 4 6 1 for details 4 6 3 Doors or covers in fire enclosures The equipment does not have N A any doors or covers 4 6 4 Openings in transportable equipment Unit not transportable N A 4 6 5 Adhesives for constructional purposes Adhesives not used for N A Conditioning temperature C time weeks securement of internal barriers or screens Underwriters Laboratories Inc Issue Date 2007 07 09 Page 26 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 7 Resistance to fire Pass 4 7 1 Reducing the risk of ignition and spread of flame Method 1 Selection and Pass application of components and materials which minimize the possibility of ignition and spread of flame Method 1 selection and application of components Pass wiring and materials Method 2 application of all of simulated fault N A condition tests 4 7 2 Conditions for a fire enclosure Pass 4 7 2 1 Parts requiring a fir
42. able to be installed in accordance with the National Electrical Code ANSI NFPA 70 and the Canadian Electrical Code Part1 and when applicable the National Electrical Safety Code IEEE C2 Pass Equipment able to be installed in accordance with ANSI NFPA 75 and NEC Art 645 unless intended for use outside of computer room and provided with such instructions Pass Equipment in wire line communication facilities serving high voltage electric power stations operating at greater than 1kV are excluded N A Special requirements apply to equipment intended for use outdoors N A 1 4 14 For Pluggable Equipment Type A the protection in the installation is assumed to be 20 A N A 1 5 1 All IEC standards for components identified in Annex P 1 replaced by the relevant requirements of CSA and UL component standards in Annex P 1 Pass 1 5 1 All IEC standards for components identified in Annex P 2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P 2 Pass 1 5 5 Interconnecting cables acceptable for the application regarding voltage current temperature flammability mechanical serviceability and the like Pass 1 5 5 For other than limited power and TNV circuits the type of output circuit identified for output connector N A 1 5 5 External cable assemblies that exceed 3 05 m in length to be types specified in the NEC and CEC
43. acturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc UL in accordance with the Follow Up Service Agreement Only those products which properly bear the UL Mark are considered as being covered by UL s Follow Up Service under the indicated Test Procedure The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc UL or any authorized licensee of UL Test Report By Reviewed By 1 Kevin Hsu Stephen Ho Associate Project Engineer Project Engineer Underwriters Laboratories Taiwan Co Ltd Underwriters Laboratories Taiwan Co Ltd Copyright 2007 Issue Date 2007 07 09 Page 1 of 2 Report Reference E213998 A12 UL 1 Enclosure Test Record Description Test Record 1 CRD Datasheets Underwriters Laboratories Inc Issue Date 2007 07 09 Page 1 of 2 Report Reference E213998 A12 UL 1 Test Record No 1 The manufacturer submitted representative production sample of 19 Panel PC Model W19B89T XXXX X can be 0 9 A Z or blank The results of this investigation indicate that the products evaluated comply with the applicable requirements in the U S and Canadian Bi National Standard for Safety of Information Technology Equipmen
44. ber of layers PCS 2 222 i N A 2 10 5 4 Wound components N A Number of layers pcs N A Two wires in contact inside wound component N A angle between 45 and 905 2 10 6 Coated printed boards No special coating used N A 2 10 6 1 General N A 2 10 6 2 Sample preparation and preliminary inspection N A 2 10 6 3 Thermal cycling N A 2 10 6 4 Thermal ageing C N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 18 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 10 6 5 Electric strength test uu u a aa 2 10 6 6 Abrasion resistance test N A Elechic strengt Test u u su sa Axes 2 10 7 Enclosed and sealed parts No hermetically sealed or N A enclosed components used Temperature T1 T2 Tma Tamb 10K C N A 2 10 8 Spacings filled by insulating compound N A Electric strength test 2 10 9 Component external terminations N A 2 10 10 Insulation with varying dimensions N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 19 of 45 Report Reference E213998 A12 UL 1
45. ch circuit overcurrent devices marked on the equipment N A 2 7 1 Standard supply outlets protected by overcurrent device in accordance with the NEC and CEC Part 1 N A 2 7 1 Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring N A 2 7 1 Additional requirements for overcurrent protection apply to equipment provided with panelboards N A 2 7 1 Non motor operated equipment requiring special overcurrent protective device marked with device rating N A 2 10 5 4 Multi layer winding wire subject to UL component wire requirements in addition to 2 10 5 4 and Annex U N A 3 1 1 Permissible combinations of internal wiring external cable sizes for overcurrent and short circuit N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 5 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict protection All interconnecting cables protected against overcurrent and short circuit N A 3 2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC Part 1 N A 3 2 1 Permitted use for flexible cords and plugs N A 3 2 1 3 2 1 Flexible cords provided with attachment plug rated 125 of equipment current rating Any Class equipment prov
46. d 3 06 Bottom view of Mother Board 3 07 Top view of Inverter Taiwan Power Conversion Inc TI1704WM 03 3 08 Bottom view of Inverter Taiwan Power Conversion Inc TI1704WM 03 Underwriters Laboratories Inc UL 05 0 ob t 0S 09 OL 08 p 61 08 06 NOLO OC 0 Ut O 08 09 05 OF 0 oz DL OG 05 09 DL 09 Ov OF DL 00 ve CO OL 29 US Or Of Oi 009 05 oL 99 0F UNCTUS T 06 w oa OS OF oe oz OF OOF 6 oa OL 39 09 oF ut 1 11111 D 00 OD Oe Of e JJ Or or DOS oe OCOf os ow or se ov OO or of WOZU 4 HU SERR E EC cm oe t3 ai tst E ESHE EEC Tranny Men Fi H 102 1 d 47 py O x zs DAREN Cap REEE GALA H artet 39 6 gt OCC ST 1410111111 APR ERR EN Alu z X z I yD Qui Zl a OOOO OR oja Aola US 9 aleje 4 alo Oa AD 06 gio o al Oo mak m Tt 4 09 DE 06 09 04 08 WM1704 10 amp Pap KA A t y Of Ob jy oC 92 OL QOL 06 ug 02 09 GG 6y s a 8 ge 09 O 08 a es 02 0t OF NM 3 08 06 OO o oz oe Ob Ju 0 0 09 1 0 99 05 GH SE 26 0 QO 06 ve 02 09 05 OE 072 UC Issue Date 2007 07 09 Page 1 of 7 Report Reference E213998 A12 UL 1 Enclosure Diagrams Supplement Id Description 4 01 T1 T2 spec
47. d bonding N A 2 6 1 Protective earthing Class IIl equipment N A 2 6 2 Functional earthing N A 2 6 3 Protective earthing and protective bonding N A conductors 2 6 3 1 General N A 2 6 3 2 Size of protective earthing conductors N A Rated current A cross sectional area mm2 AWG a ista iin les Hide tit E h p ADATA ade I 2 6 3 3 Size of protective bonding conductors N A Rated current A cross sectional area mm2 D co 2 6 3 4 Resistance Ohm of earthing conductors and their N A terminations test current A 2 6 3 5 Colour of insulation N A 2 6 4 Terminals N A 2 6 4 1 General N A 2 6 4 2 Protective earthing and bonding terminals N A Rated current A type and nominal thread diameter mm uuu sasaqa ass aska q mua 2 6 4 3 Separation of the protective earthing conductor N A from protective bonding conductors 2 6 5 Integrity of protective earthing N A 2 6 5 1 Interconnection of equipment N A 2 6 5 2 Components in protective earthing conductors and N A protective bonding conductors 2 6 5 3 Disconnection of protective earth N A 2 6 5 4 Parts that can be removed by an operator N A 2 6 5 5 Parts removed during servicing N A 2 6 5 6 Corrosion resistance N A 2 6 5 7 Screws for protective bonding N A 2 6 5 8 Reliance on telecommunication network or cable N A distribution system Underwriters Laboratories Inc
48. d two PS2 ports housed within a metal enclosure CC1 0 Model Differences CC1 1 N A CD1 0 Additional Information CD1 1 N A CE1 0 Technical Considerations CE1 2 The product was submitted and tested for use at the maximum ambient temperature Tma permitted by the manufacturer s specification of 40 C CE1 3 The means of connection to the mains supply is Pluggable A or B Detachable power cord CE1 8 The following accessible locations with circuit schematic designation are within a limited current circuit Secondary side of D A inverter CE1 9 The following circuit locations with circuit schematic designation were investigated as a limited power source LPS USB 1394 port and PS 2 ports CE1 14 The following are available from the Applicant upon request Installation Safety Instructions Manual CE1 15 The power supply in this equipment was Investigated to an earlier edition amendment of UL 60950 As part of the investigation of this product the power supply and its test report were reviewed and found to comply with UL 60950 1 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 6 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 GENERAL Pass 1 5 Components Pass 1 5 1 General Pass Comply with IEC 60950 or relevant component see appended table 1 5 1 Pass standard 1 5 2 Evaluation and
49. e enclosure A fire enclosure covers all Pass parts 4 7 2 2 Parts not requiring a fire enclosure N A 4 7 3 Materials Pass 4 7 3 1 General See below Pass 4 7 3 2 Materials for fire enclosures The fire enclosure is metal Pass 4 7 3 3 Materials for components and other parts outside Connectors are made of Pass fire enclosures materials of Class V 2 minimum 4 7 3 4 Materials for components and other parts inside fire PWBs are rated min V 1 Pass enclosures All internal materials are rated V 2 or better or are mounted on a PWB rated V 1 or better Internal wiring is UL Recognized marked VW 1 or FT 1 and strapped by individual cable ties where needed See Table 1 5 1 for material information 4 7 3 5 Materials for air filter assemblies The equipment does not have N A any air filters 4 7 3 6 Materials used in high voltage components No high voltage components N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 27 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass 5 1 Touch current and protective conductor current N A 5 1 1 General N A 5 1 2 Equipment under test EUT N A 5 1 3 Test circuit N A 5 1 4 Application of measuring instrument N A 5 1 5 Test procedure N A 5 1 6 Test measurements N A Test voltage NI l Measured touch current m
50. e tetas fe Manufacturer aa RSE Rated values l l ee Method of protection C 1 Overload test N A C 2 Insulation N A Protection from displacement of windings i N A D Annex D MEASURING INSTRUMENTS FOR TOUCH CURRENT TESTS N A D 1 Measuring instrument N A D 2 Alternative measuring instrument N A E Annex E TEMPERATURE RISE OF A WINDING N A F Annex F MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES Pass see 2 10 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 34 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict G Annex G ALTERNATIVE METHOD FOR DETERMINING MINIMUM N A CLEARANCES G 1 Summary of the procedure for determining N A minimum clearances G 2 Determination of mains transient voltage V N A G 2 1 AC mains supply N A G 2 2 DC mains supply N A G 3 Determination of telecommunication network N A transient voltage V G 4 Determination of required withstand voltage V N A G 5 Measurement of transient levels V N A G 6 Determination of minimum clearances i N A H ANNEX H IONIZING RADIATION see 4 3 13 N A J Annex J TABLE OF ELECTROCHEMICAL POTENTIALS see 2 6 5 6 N A Metal use K ANNEX K THERMAL CONTROLS see 1 5 3 and 5 3 7 N A K 1 Making and brea
51. ection of the telecommunication wiring system from overheating N A Max output current A I Current limiting method CONNECTION TO CABLE DISTRIBUTION SYSTEMS N A 7 1 Protection of cable distribution system service persons and users of other N A equipment connected to the system from hazardous voltages in the equipment 7 2 Protection of equipment users from overvoltages N A on the cable distribution system 7 3 Insulation between primary circuits and cable N A distribution systems 7 3 1 General N A 7 3 2 Voltage surge test N A 7 3 3 Impulse test N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 30 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict A Annex A TESTS FOR RESISTANCE TO HEAT AND FIRE N A A 1 Flammability test for fire enclosures of movable equipment having a total mass N A exceeding 18 kg and of stationary equipment see 4 7 3 2 A 1 1 Samples eorr hoe eme E Wall thickness MM s sss sess A 1 2 Conditioning of samples temperature C i N A A 1 3 Mounting of samples N A A 1 4 Test flame N A A 1 5 Test procedure N A A 1 6 Compliance criteria N A Sample 1 burning time s
52. en no class of insulation is given min insulation 105 degree C assumed User accessible area material is Metal 70 degree C Tmax degree C 70 degree C 4 5 2 TABLE ball pressure test of thermoplastics N A allowed impression diameter mm part test temperature C impression diameter mm supplementary information 4 7 TABLE resistance to fire Pass part manufacturer of material type of material thickness mm flammability class supplementary information Please see Table 1 5 1 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 42 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 5 2 TABLE electric strength tests impulse tests and voltage surge tests test voltage applied between test voltage V breakdown a c d c Yes No supplementary information 5 3 TABLE fault condition tests Pass ambient temperature C See below model type of power supply Se manufacturer of power supply SI rated markings of power supply SJ component fault test voltage testtime fuse fuse current result No V No A
53. er the NEC and CEC Part 1 N A 3 2 3 Permanently connected equipment may have N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 6 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict 3 2 3 terminals or leads not smaller than No 18 AWG 0 82 mm and not less than 152 mm in length for connection of field installed wiring If supply wires exceed 60 C marking indicates use of 75 C or 90 C wiring for supply connection as appropriate N A 3 2 3 Equipment compatible with suitable trade sizes of conduits and cables N A 3 2 5 Length of power supply cord limited to between 1 5 and 4 5 m unless shorter length used when intended for a special installation N A 3 2 5 Conductors in power supply cords sized according to NEC and CEC Part I N A 3 2 5 Power supply cords and cord sets incorporate flexible cords suitable for the particular application N A 3 2 6 Strain relief provided for non detachable interconnecting cables not supplied by a limited power source N A 3 2 9 Adequate wire bending space and volume of field wiring compartment required to properly make the field connections N A 3 2 9 3 3 3 3 Equipment intended solely for installation in Restricted Access Locations using low voltage d c systems may not need provision for co
54. ided with 15 or 20 A standard supply outlets Edison base lampholders or single pole disconnect device provided with a polarized type attachment plug N A N A 3 2 1 2 Equipment intended for connection to DC mains supply power systems complies with special wiring requirements e g no permanent connection to supply by flexible cord N A 3 2 1 2 Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing N A 3 2 1 2 Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection N A 3 2 1 2 Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment N A 3 2 1 2 Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment N A 3 2 1 2 Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard N A 3 2 3 Permanently connected equipment has provision for connecting and securing a field wiring system i e conduit or leads etc p
55. ignals N A NAC Equipment intended for use with a generic secondary protector marked with suitable instructions N A NAC Equipment intended for use with a specific primary or secondary protector marked with suitable instructions Underwriters Laboratories Inc N A Issue Date 2007 07 09 Page 10 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict NAF Household Home Office Document Shredders N A NAF 1 7 Markings and instructions alert the user to key safety considerations related to use of shredders including not intended to be used by children avoid touching document feed opening avoid clothes and hair entanglement and avoid aerosol products N A NAF 2 8 3 Safety interlock cannot be inadvertently activated by the articulated accessibility probe figure NAF 1 N A NAF 3 4 Provided with an isolating switch complying with 3 4 2 including 3 mm contact gap with appropriate markings associated with the switch N A NAF 4 4 Hazardous moving parts are not accessible to the user as determined using the articulated accessibility probe figure NAF 1 and the accessibility probe wedge figures NAF 2 NAF 3 N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 1 of 45 Report Reference E213998
56. it is not a hand held N A equipment 1 6 4 Neutral conductor N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 8 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 7 Marking and instructions Pass 1 7 1 Power rating Rating marking readily visible Pass to operator Rated voltage s or voltage range s V 12V dc Pass Symbol for nature of supply for d c only IEC 60417 No 5031 provided Pass on marking label Rated frequency or rated frequency range Hz dc N A Rated current MA or Al 1 09 17 A Pass Manufacturer s name or trademark or identification WINMATE COMMUNICATION Pass 1 mE INC Type model or type reference W19B89T XXXX X can be 0 Pass 9 A Z or blank Symbol for Class Il equipment only N A Other svmbole esee Additional symbols may be Pass provided when submitted for National Approval Certification marks ose IUL C UL Pass 1 7 2 Safety instructions Safety instructions in English Pass Other languages will be provided when submitted for national approval 1 7 3 Short duty cycles N A 1 7 4 Supply voltage adjustment 0 N A 1 7 5 Power outlets on the equipment No standard power outlets are
57. king capacity N A K 2 Thermostat reliability operating voltage V N A K 3 Thermostat endurance test operating voltage V N A K 4 Temperature limiter endurance operating voltage N A WA K 5 Thermal cut out reliability N A K 6 Stability of operation N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 35 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict L Annex L NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL Pass BUSINESS EQUIPMENT see 1 2 2 1 and 4 5 1 L 1 Typewriters N A L 2 Adding machines and cash registers N A L 3 Erasers N A L 4 Pencil sharpeners N A L 5 Duplicators and copy machines N A L 6 Motor operated files N A L 7 Other business equipment Pass M Annex M CRITERIA FOR TELEPHONE RINGING SIGNALS see 2 3 1 N A M 1 Introduction N A M 2 Method A N A M 3 Method B N A M 3 1 Ringing signal N A M 3 1 1 Frequency HZ TT M 3 1 2 Voltage Mu Resell e M 3 1 3 Cadence time s voltage V M 3 1 4 Single fault current mA M 3 2 Tripping device and monitoring voltage i N A M 3 2 1 Conditions for use of a tripping device or a N A monitoring voltage M 3 2 2 Tripping device N A M 3 2 3 Monitoring voltage V
58. l connection of the equipment earthing conductor Class III unit N A 1 7 7 Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used N A 1 7 7 Marking located adjacent to terminals and visible during wiring N A Screw shell of Edison base lampholder tied to the neutral conductor N A 2 1 1 1 Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover No TNV present N A 2 3 1 b Other telecommunication signaling systems e g message waiting than described in 2 3 1 b are subject to M 4 N A 2 3 1 b For TNV 2 and TNV 3 circuits with other than ringing signals and with voltages exceeding 42 4 Vp or 60 V d c the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7 1 mA peak or 30 mA d c under normal conditions N A 2 3 1 b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M 3 1 4 N A Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and
59. lent Recognized marked VW 1 or FT 1 and strapped by individual cable ties where needed 5 1 8 2 Special earthing provisions and instructions for N A equipment with high touch current due to telecommunication network connections 5 1 8 3 Touch current due to ringing voltage for equipment N A containing telecommunication network leads 5 3 6 Overloading of SELV connectors and printed wiring See appended table 5 3 Pass board receptacles accessible to the operator 5 3 6 Tests interrupted by opening of a component N A repeated two additional times 5 3 8 1 Test interrupted by opening of wire or trace subject N A to certain conditions 6 Specialized instructions provided for telephones No TNV present N A that may be connected to a telecommunications network 6 Marking identifying function of telecommunication N A type connectors not used for connection to a telecommunication network 6 2 1 Special requirements for enameled wiring used as N A electrical separation provided between parts Underwriters Laboratories Inc Issue Date 2007 07 09 Page 9 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict 6 2 1 connected to telecommunication network and telecommunication circuitry intentionally isolated from network Digital line termination equipment e g NCTE subject to separation requirements N A
60. nnecting and securing a field wiring system A method of securing wiring or instructions provided to ensure the wiring is protected from abuse Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with 3 3 Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3 3 if wiring is reliably separated N A N A N A 3 3 1 Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means N A Wire binding screw terminal permitted for connection of No 10 AWG 5 3 mm or smaller conductor if provided with upturned lugs cupped washer or equivalent retention N A Terminals accept wire sizes gauge used in the N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 7 of 10 Report Reference E213998 A12 UL 1 IEC 60950 1 SubClause Difference Test Result Remark Verdict U S and Canada Terminals accept current carrying conductors rated 125 of the equipment current rating N A Field wiring terminals marked to indicate the material s of the conductor appropriate for the terminals used N A Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor N A Field wiring connections made through the use of suitable p
61. ressure connectors including set screw type solder lugs or splices to flexible leads N A 3 4 2 Separate motor control device s required for cord connected equipment rated more than 12 A or with motor rated more than 1 3 hp or more than 120 V N A 3 4 8 Vertically mounted disconnect devices oriented so up position of handle is on N A 3 4 11 For computer room applications equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means N A 4 2 8 1 Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more The equipment does not have any CRT N A 4 2 9 Compartment housing high pressure lamp marked to indicate risk of explosion The equipment does not have any high pressure lamps N A Loading test for equipment with handle s used to support more than 9 kg tested at four times the weight of the unit N A In addition to the IEC requirements Direct Plug in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements N A 4 3 12 The maximum quantity of flammable liquid stored in equipment complies with ANSI NFPA 30 Table NAE 6 The equipment does not use any flammable liquids N A 4 3 12 Equipment using replenishable liquids marked to indicate type of liquid to be used N A 4 3 13 2 Equipment that produces x radiation and does not comply with
62. s test voltage V s ass a petite See jr e zm S below ja NA ieee eee 4 ya p E 1 sre 7 5 Sp D ES maximum temperature T of part at T C allowed Tmax C 19 Panel PC model W19B89T XXXX Adapter Model LI SHIN 0227B12110 Normal Condition Condi Conditio m tion 1 n1 Origi Shift to nal 40 Underwriters Laboratories Inc Issue Date 2007 07 09 Page 41 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 Ambient 23 8 40 0 2 T1 coil 70 6 186 8 105 3 CE1 coil 52 1 68 3 105 4 PWB near CPU 48 0 64 2 105 5 RTC Body 44 7 60 9 100 6 CPU fan 38 2 4 105 7 System fan 41 7 57 9 105 7 HDD body 48 9 65 1 8 Enclosure outside near CPU 33 5 49 7 70 temperature T of winding R O Re Q TI allowed insulation Tmax C class supplementary information The temperatures were measured under worst case normal mode defined in 1 2 2 1 and as described in 1 6 1 at voltages as described in 1 4 5 With a specified ambient temperature of 40 degree C the max temperature is calculated as follows Components with max absolute temp of 100 degree C RTC Tmax degree C 100 degree C max absolute temp of 105 degree C PWB CE1 T1 Tmax degree C 105 degree C wh
63. s Laboratories Inc Issue Date 2007 07 09 Page 3 of 45 Report Reference E213998 A12 UL 1 SPECIFIC TECHNICAL CRITERIA UL 60950 1 First Edition Information technology equipment Safety Part 1 General Requirements Report Reference No E213998 A12 UL 1 Compiled by u Kevin Hsu Reviewed by Stephen Ho Date of issue 2007 07 09 Standards 1 UL 60950 1 1st Edition 2006 07 07 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 03 1st Edition 2006 07 Information Technology Equipment Safety Part 1 General Requirements Test procedure Listing Non standard test method N A Test item description 19 Panel PC Trademark uNone Model and or type reference W19B89T XXXX X can be 0 9 A Z or blank Rating s 1 12Vdc 9 17A Particulars test item vs test requirements Equipment mobility seen movable Operating condition sees eee eee continuous Mains supply tolerance Yo No direct connection Tested for IT power systems
64. t Part 1 Including Electrical Business Equipment CAN CSA C22 2 No 60950 1 03 UL 60950 1 1st Edition dated April 01 2003 including revisions through revision date July 7 2006 Unless otherwise noted in the above list of tests all tests were conducted by Universal Standard Service Inc located at Lin Kou Shiang Taipei Hsien Taiwan under the CAP program Tests noted by the initials UL were witnessed by UL staff member Test results reported relate only to the items tested The following tests were conducted Test Testing Location Comments End Product Reference Page General Guidelines Input Single Phase 1 6 2 Limited Current Circuit Measurement 2 4 1 2 4 2 UL Limited Power Source Measurements 2 5 Loading 4 2 10 Lithium Battery Reverse Current Measurement 4 3 8 UL Heating 4 5 1 1 4 12 1 4 13 Abnormal Operation 5 3 1 5 3 8 2 Overload of Operator Accessible Connector 5 3 6 UL Test results are valid only for the tested equipment These tests are considered representative of the products covered by this Test Report The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard s referenced at the beginning of this Test Report Underwriters Laboratories Inc Project 07CA25154 File E213998 Page 1 of 1 Compliance Review Kevin Hsu Conducted by 2007 7 8 Printed Name
65. testing of components Components certified to IEC Pass harmonized standard and checked for correct application Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 60950 1 and the relevant component Standard Components for which no relevant IEC Standard exist have been tested under the conditions occurring in the equipment using applicable parts of IEC 60950 1 1 5 3 Thermal controls There are no thermal controller N A used 1 5 4 Transformers N A 1 5 5 Interconnecting cables Interconnecting cables comply Pass with the relevant requirements of this standard 1 5 6 Capacitors in primary circuits N A 1 5 7 Double insulation or reinforced insulation bridged N A by components 1 5 7 1 General N A 1 5 7 2 Bridging capacitors N A 1 5 7 3 Bridging resistors N A 1 5 7 4 Accessible parts N A 1 5 8 Components in equipment for IT power systems N A 1 6 Power interface Pass 1 6 1 AC power distribution systems Class III unit N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 7 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 6 2 Input current see appended table 1 6 2 Pass The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10 under NORMAL LOAD 1 6 3 Voltage limit of hand held equipment The un
66. uits N A 4 PHYSICAL REQUIREMENTS Pass 4 1 Stability N A Angle of 10 N A Test2torce N x tee eh te ts N A 4 2 Mechanical strength Pass 4 2 1 General Class IIl equipment N A 4 2 2 Steady force test 10 N N A 4 2 3 Steady force test 30 N N A 4 2 4 Steady force test 250 N N A 4 2 5 Impact test N A Fall test N A Swing test N A 4 2 6 Drop test N A 4 2 7 Stress relief test N A 4 2 8 Cathode ray tubes The equipment does not have N A any CRT Picture tube separately certified N A 4 2 9 High pressure lamps The equipment does not have N A any high pressure lamps 4 2 10 Wall or ceiling mounted equipment force N Mounting means withstands Pass four times unit weight Underwriters Laboratories Inc Issue Date 2007 07 09 Page 23 of 45 Report Reference E213998 A12 UL 1 IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 3 Design and construction Pass 4 3 1 Edges and corners All edges and corners are Pass judged to be sufficiently well rounded so as not to constitute a hazard 4 3 2 Handles and manual controls force N s N A 4 3 3 Adjustable controls The equipment does not have N A a voltage selector 4 3 4 Securing of parts Electrical and mechanical Pass connections can be expected to withstand usual mechanical stress 4 3 5 Connection of plugs and sockets The equipment does not have N A any
67. upplied by Pass approved AC adapter The SELV reliability were considered as an element of certify power adapter 2 2 2 Voltages under normal conditions V All accessible voltages are Pass less than 42 4 Vp or 60 V dc and are classified as SELV 2 2 3 Voltages under fault conditions V N A 2 2 3 1 Separation by double insulation or reinforced N A insulation method 1 2 2 3 2 Separation by earthed screen method 2 N A 2 2 3 3 Protection by earthing of the SELV circuit method N A 3 2 2 4 Connection of SELV circuits to other circuits SELV connected to limited Pass current circuit 2 3 TNV circuits N A 2 3 1 Limits No TNV circuit N A Type of TNV circuits eee 2 3 2 Separation from other circuits and from accessible N A parts Insulation employed a 2 3 3 Separation from hazardous voltages N A Insulation employed esses 2 3 4 Connection of TNV circuits to other circuits N A Insulation employed 2 3 5 Test for operating voltages generated externally N A Underwriters Laboratories Inc Issue Date 2007 07 09 Page 12 of 45 Report Reference E213998 A12 UL 1 Clause IEC 60950 1 Requirement Test Result Remark Verdict 2 4 Limited current circuits Pass 2 4 1