Puronics IQ WholeHouse Water Conditioner Service Manual
Contents
1. DO in the upper left hand corner of the screen Press the EXTRA CYCLE button Use this display to adjust the Regeneration Time This option setting is identified by RT in the upper left hand corner of the screen RT 4nn y LUL os 4 Press the EXTRA CYCLE button Use this display to adjust the Feed Water Hardness This option setting is identified by H in the upper left hand corner of the screen LI 7 1 EIN f HN LI Range 1 199 hardness 5 Press the EXTRA CYCLE button Use this display to adjust the Safety Factor This option is identified by SF in the upper left hand corner of the screen 6 Press the EXTRA CYCLE button to end User Programming Mode Step 3 Set Time of Day If you should have a power failure or want to adjust for Daylight Saving Time follow these Instructions Press and hold either the UP or DOWN buttons until the programming icon replaces the service icon and the parameter display reads DO Tiri Adjust the display time with the UP and DOWN buttons J IAD When the desired time is set press the EXTRA CYCLE sl L LI button to resume normal operation The unit will also return to normal operation after 5 seconds if no buttons are pressed During a power outage the control goes into a power saving mode It does not monitor water usage during a power outage but it does store the volume remaining at the time of power failure It will continue to keep time and the
2. NOT CHANGE 16 Press the EXTRA CYCLE button to display the Rapid Rinse Time preset to 12 minutes DO NOT CHANGE 17 Press the EXTRA CYCLE button to display the Flow Meter Type preset to 34 Paddle Wheel Meter DO NOT CHANGE 18 Press the EXTRA CYCLE button to display the Service Call Area Code preset to 800 Press the UP and DOWN arrows to enter new Area Code 19 Press the EXTRA CYCLE button to display the Service Call Prefix preset to 339 Press the UP and DOWN arrows to enter new Prefix 20 Press the EXTRA CYCLE button to display the Service Call Suffix preset to 8780 Press the UP and DOWN arrows to enter new Suffix Ne 8780 21 Press the EXTRA CYCLE button to save all settings and exit Master Programming Mode Step 2 Set the Hardness In User Programming Mode 1 2 3 User Programming Mode Options pO 4 Day Override The timer s day override setting Regeneration The time of day that the system Time will regenerate meter delayed timeclock and day of week systems The hardness of the inlet water used to calculate system capacity for metered systems RC or SF Reserve Capacity The fixed reserve capacity Current Day The current day of week Feed Water Hardness Press the UP and DOWN buttons for five seconds while in service and the time of day is NOT set to 12 01PM Use this display to adjust the Day Overide This option setting is identified by
3. passage of days for a minimum of 48 hours in the event of power failure The Time of Day flashes when there has been a power failure Press any button to stop the time of Day from flashing If power fails while the unit is in regeneration the control will save the current valve position before it shuts down When power is restored the control will resume the regeneration cycle from the point where power failed Step 4 Set to Regenerate Today To initiate a manual regeneration at the preset delayed regeneration time press the EXTRA CYCLE button The service icon will flash to indicate that a regeneration is queued f you pressed the EXTRA CYCLE button in error pressing the button again will cancel the request To Initiate a manual regeneration immediately press and hold the EXTRA CYCLE button for five seconds The system will begin to regenerate immediately Note If the brine tanks does not contain salt fill with salt before initiating a manual regeneration How to Demonstrate the Service Call Screen 1 Enter Diagnostics Mode by pressing the UP and EXTRA CYCLE buttons simultaneously Press the DOWN button once or the UP button seven times to reach Call Flow Remaining Press and hold the EXTRA CYCLE button for 5 seconds and the Service Call Screens will be activated sess This same method can be used to deactivate the Service Call Screens without resetting the Call Flow Remaining if it was activated this w
4. view the Peak Flow Rate since the last regeneration cycle PF o Bb Press the UP button regeneration cycle Press the UP button regeneration Press the UP button Press the UP button Press the UP button Press the UP button Use this display to view the Hours in Service since the last i Fan ri LI LI LA agu Use this display to view the Reserve Capacity VL E LI Li Vi L4 om Use this display to view the Software Version b Use this display to view the Total Flow tF nnm Oo UUS Use this display to view the Call Flow Remaining LE nnm LI LI EL agu
5. INSTALLATION PROGRAMMING MANUAL PURONICS WATER CONDITIONER Model Terminator MP With SilverShield HYgene Bacteriostatic Protection PURONICS The Next Generation of lonics Solutions Manufactured by Puronics Water Systems Inc 5775 Las Positas Road Livermore CA 94551 800 339 8780 www puronics com PURONICS Service Call The Model MP control valve features an automatic Service Call Reminder The valve measures water volume usage and based on the life expectancy of the SilverShield HYgene bacteriostatic media for the unit will flash a screen message of CALL TECH and phone number Timer Features Parameter Data PM Display Display Indicator Error i E Information leon he wont L Flow Indicator aa T9 f l Ll x1000 Indicator Programming Icon lt gt a w Foe Extra Cycle Up Down X Button Button Button y Power backup continues to keep time and the passage of days for a minimum of 48 hours in the event of power failure During a power outage the control goes into power saving mode It does not monitor water usage during a power failure but it does store the volume remaining at the time of power failure While in service the display alternates between time of day and volume remaining until next regeneration The Flow Indicator flashes when outlet flow is detected The Service Icon flashes if a regeneration cycle has been queued A Regene
6. T UdFFF Press the EXTRA CYCLE button to display the Control Type preset to Meter Delayed DO NOT CHANGE Press the EXTRA CYCLE button to display the Number of Tanks preset to Single Tank DO NOT CHANGE N l N f sooo e N Press the EXTRA CYCLE button to display the Unit Capacity preset to 20000 for an 8 tank 30000 for a 10 tank and 40000 for a 12 tank DO NOT CHANGE tL unn L LILI Press the EXTRA CYCLE button to display the Feedwater Hardness Selection preset to 10 DO NOT CHANGE Vf LI Press the EXTRA CYCLE button to display the Reserve Selection preset to Safety Factor DO NOT CHANGE 10 Press the EXTRA CYCLE button to display the Days Override preset to 20 DO NOT CHANGE 11 Press the EXTRA CYCLE button to display the Regeneration Time preset to 2 00 AM DO NOT CHANGE 12 Press the EXTRA CYCLE button to display the Brine Fill Time preset to 12 minutes for 8 tank 14 minutes for 10 tank and 16 minutes for 12 tank DO NOT CHANGE 13 Press the EXTRA CYCLE button to display the Service Brine Soak Time preset to 58 minutes for 8 tank 56 minutes for 10 tank and 54 minutes for 12 tank DO NOT CHANGE 14 Press the EXTRA CYCLE button to display the Backwash Time preset to 10 minutes DO NOT CHANGE 15 Press the EXTRA CYCLE button to display the Brine Draw Time preset to 58 minutes DO
7. ay How to Turn Off Service Call Alert and Reset Total Flow and Call Flow Remaining Turn off the Service Call Alert and to reset the Call Flow to full volume enter and complete Master Programming Mode No values need to be changed but it must be exited normally by completing all parameters DIAGNOSTIC PROGRAMMING MODE Diagnostic Programming Mode Options Abbreviation Parameter Description FR Flow Rate Displays the current outlet flow rate PF Peak Flow Rate Displays the highest flow rate measured since the last regeneration HR Hours in Service Displays the total hours that the unit has been in service VU Volume Used Displays the total volume of water treated by the unit RC Reserve Capacity Displays the system s reserve capacity calculated from the system capacity feedwater hardness and safety factor SV Software Version Displays the software version installed on the controller TF Total Flow Displays the total volume of water treated since reset CF Call Flow Remaining Displays the remaining volume of water until next Service Call 1 Press the UP and EXTRA CYCLE buttons for five seconds while in service The timer will exit Diagnostic Mode after 60 seconds if no buttons are pressed Press the EXTRA CYCLE button to exit Diagnostic Mode at any time 2 Use this display to view the current Flow Rate FH JJ EJ 3 Press the UP button Use this display to
8. ration can be triggered immediately by pressing the EXTRA CYCLE button for five seconds The Parameter Display displays the current Cycle Step BW BF RR etc during regeneration and the date display counts down the time remaining for that step While the valve is transferring to a new cycle step the display will flash The parameter display will identify the destination cycle step BW BF RR etc and the data display will read Once the valve reaches the cycle step the display will stop flashing and the data display will change to the time remaining During regeneration the user can force the control to advance to the next cycle step immediately by pressing the EXTRA CYCLE button Step 1 Set the Service Call Number in Master Programming Mode 1 Press and hold either the UP or DOWN buttons until the programming icon replaces the service icon and the parameter display reads DO Adjust the display time with the UP and DOWN buttons to 12 01PM Press the EXTRA CYCLE Button to exit Setting Time of Day mode Then press and hold the UP and DOWN buttons together until the programming icon replaces the service icon and the Display Format screen appears ET rani ALLE cove The first screen that appears when entering Master Programing Mode is the Display format preset to U S Gallons DO NOT CHANGE Press the EXTRA CYCLE Button to display the Valve Type preset to Downflow Flow Fill First DO NOT CHANGE W
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - Parts Express NV-5516W, NV-5516B, NV-5516SS.sp 2 3M™ Multi-Touch C4667PW Chassis Display User Guide LaserGas Impresora digital en color UP-D25MD Impresora analógica ビジュアルサポートデスクの受付時間変更について 1769-IN032A-IT-P, Modulo Compact di ingresso sink/source 24 V cc National Instruments SCXI-1161 User's Manual Operation Manual DP-GIGANTE TT 2015 Copyright © All rights reserved.