Currenza C2 Coin Changer Manual For
Contents
1. Special notes which are to facilitate the use of the devices At the beginning of a chapter you will find a short guide which summarises the content of the chapter 12 b 2 3 Requests to perform an action are numbered in another typeface and if possible listed in a table AFAA DISPLAY TEXTS are set in small capitals BUTTONS and MENU ITEMS are shown in bold capitals Crane Co Company ABOUT THE MANUAL c Configuration Additional technical documentation Apart from the manual you already have there is further documentation for the currenza c and HENRI setting module e g about service work and technical data All product descriptions are available in a compressed PDF format at www nri24 com Download 8 National Rejectors Inc GmbH Buxtehude LU c Configuration GENERAL INFORMATION 2 _ gt General information In order to keep the manual as short as possible this chapter provides you with all general information which will not be repeated in the following chapters e g connecting the HENRI setting module The vending machine interfaces This manual refers to the configuration of all currenza c models The models have different configuration options e g due to different vending machine interfaces The chapter title supplement put in brackets limits a certain function or setting for one or several interfaces The user interfaces Beyond that the currenza c models
2. National Rejectors Inc GmbH Buxtehude LU c Configuration CASH ACCEPTANCE Limiting acceptance of coins and banknotes only c BDV Executive In order to prevent the vending machine from being used as a money changer you can seta maximum amount of money which may be accepted during a single vending operation acceptance limitation If this amount is reached or exceeded the acceptance of coins and bills is inhibited only after a transaction and automatically see section Configuring Committed to vend or change return at any time in Chap 5 Prices and vending modes C In addition you may set the coin changer so that the change is returned To configure the acceptance limitation Quick approach Main menu gt FE Settings gt Operating modes gt Limitations gt Acceptance limit Press key How often Effect 1 1x You enter the main menu You enter the Grrmwe menu The 2 dex required menu item has already been selected 3 1x You enter submenu OPERATING MODES 4 until Limitations You want to enter submenu LIMITATIONS l You enter the submenu The required 5 1x menu item has already been selected You want to set the acceptance 6 1x limitation 7 oe until required digit You highlight the digit to be set 8 DE until required value This value is to be set Q Please repeat steps 7 and 8 to set the other digits of the acceptance limitation if necessary You lock the set acceptance limitation 10 E in memory You re
3. 33 CASH ACCEPTANCE c Configuration Inhibiting high value coins if there is not enough change only c BDV Executive If you want high value coins to be no longer accepted whenever the machine displays tube empty see section Configuring conditions for tube empty message only c BDV Executive in Chap 7 Change payout they can be inhibited automatically depending on this message To inhibit release a certain coin if there is not enough change Quick approach Main menu gt E Settings gt Inhibit mask gt Inhibit if tube empty Press key How often Effect 1 1 x You enter the main menu 2 E You enter the SETTING menu 3 until Inhibit mask You want to enter submenu INHIBIT MASK 4 1x You enter the submenu 5 uil Inhibit if tube Omar ere ene GG change 6 1x Now you can select the relevant coin 7 until coin desired You want to inhibit release this coin 8 1x Now you can inhibit release this coin 9 until setting desired Ee 10 1x You lock the setting in memory 11 Tr You return to main menu operating 34 mode National Rejectors Inc GmbH Buxtehude LU c Configuration CASH ACCEPTANCE Optimising acceptance of genuine coins rejection of fraud coins defining acceptance tolerances For the acceptance of high value coins programmed the coin changer is capable of having up to three acceptance bands with different acceptance tolerances In order that genuine coins are always accepted and fraud coins
4. Effect 1 1x You enter the main menu You enter the SETTING menu The 2 1X correct menu item has already been selected 3 1x You enter submenu OPERATING MODES 4 until Security stock to You want the security stock to be Sent VMC NOT TO BE SENT TO THE VMC 5 1x Now can set the function The security stock is to be sent not to 6 until setting desired be cent 7 E 1x You lock the setting in memory You return to main menu operating 8 1 x 2 x SE Enabling VMC to payout security stock with DISPENSE only c MDB If you want the vending machine to be able to pay out also the security stock using the DISPENSE command Quick approach Main menu zs Ke Gettinge _Opsrating modes Gecutitv stock inthe tubes Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 1x correct menu item has already been d selected 3 D 1x You enter submenu OPERATING MODES 4 until Security stock in You want a PayasLe norT PAYABLE security e the tubes stock 5 E TX Now you can set the function You want the VMC to be able not to be 6 EE able to payout the security stock T 1x You lock the setting in memory You return to main menu operating 8 1 x 2 x mede CiD National Rejectors Inc GmbH Buxtehude 39 Crane Co Company CHANGE PAYOUT c Configuration H Change payout lt gt This chapter describes how to adapt the change payout to the machine environment e Reassigning coin
5. Inc GmbH Buxtehude 59 Crane Co Company PERIPHERAL c Configuration Setting up communication with external audit unit only c BDV Executive If there is an external machine audit unit connected the only thing to do is to set up communication with the coin changer To activate the communication between coin changer and external audit unit Quick approach Main menu gt EF settings gt _reripheral gt Audit unit np Ehe machine Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu 3 until Peripheral You want to enter submenu PERIPHERAL 4 dE You enter the submenu 5 until Audit unit in the You want to set up the communication machine with the external audit unit 6 1x Now you can set up communication You want the communication to be 7 until setting desired Aone NoT ACTIVE 8 a 1x You lock the setting in memory You return to main menu operating 9 1 x 2 x mode 60 National Rejectors Inc GmbH Buxtehude LU c Configuration AUDIT 9 Audit option RN This chapter describes all settings to be considered if the coin changer is equipped with an internal audit module You learn how to set the vending machine number set date and time specify data to be printed set the output device format device type activate the maximum IrDA readout speed only c with IrDA interface on coin validator C The language of the audit receipts has been selected with the dial
6. gt Other settings gt Display contrast Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu You want to enter submenu OTHER 3 until Other settings SCHEI A IEX You enter the submenu 5 until Display contrast You want to set the DISPLAY CONTRAST 6 lex Now you can set the CONTRAST 7 D Cc until required digit You highlight the digit to be changed This value is to be set the contrast is 8 Ad Pinal ess lisse zelt changing with the value set 9 Please repeat steps 7 and 8 to set the second digit of the contrast value if necessary You lock the set value in memory The 10 Ve display has the new contrast You return to main menu operating 11 1 x 2 x mode 12 National Rejectors Inc GmbH Buxtehude LU c Configuration PRESETTINGS Specifying display message for operating mode only c blue During normal operating mode the currenza c blue may display one of the following messages e Total CHANGE stock in coin cassette e CasHBox stock and total change stock in coin cassette by turns Cashbox Total change stock and coin number per tube 46 13 INVENTORY Inventory oro 20 LI 000 000 008 000 048 025 To specify the display message Quick approach Main menu gt BE Settings gt Other settings gt Display Press key How often Effect 1 1x You enter the main menu 2 E lex You enter the SETTING menu You want to enter submenu OTHER 3 until Other sett
7. until Audit module 1x until Configurate printer interface 1x until IrDA high speed 1x until setting desired Effect You enter the main menu You enter the SETTING menu You want to enter submenu Aupbit MODULE You enter the submenu You want to enter submenu CONFIGURATE PRINTER INTERFACE You enter the submenu You want to activate deactivate the highest readout speed Now you can set the function You want to read out audit data with 19 200 Bd at a slower rate You lock the selected readout speed in memory You return to main menu operating mode 67 BASIC SETTINGS c Configuration 10 Basic settings lt gt This chapter describes how to perform basic changer settings that seldom need to be changed e g for a new installation site Smallest coin value as a basis of calculation for coin values prices Alternative coin value for second currency or as token value Currency or calling code MDB level Mains or battery operation Wake up time Write protection for coin changer configuration Changing smallest coin value base value For the coin changer the smallest coin value is the reference value for the data management of all programmed coin and token values as well as prices The values of all accepted coin types tokens and all prices must be integral multiples of the smallest coin value it is no longer an integral and common divisor the coin token Whenever the smallest coin value is chang
8. S Safety instructions 7 Save configuration 75 Second currency 70 Security Level 35 Stock 38 Of machine compensate recycler 53 Payout DISPENSE 39 Per tube 38 To VMC 39 Transmit with tube filling level 39 Select tube cassette 40 Selling price Display 26 Extra for card payment 57 Manage 23 25 Set 24 Sensors tubes 18 Setting module Connect 10 General information 9 Settings Clone 76 For printer 64 Short reference guide additional 8 Simple payout 45 Single Motor payout 45 Vend 28 Smallest coin value 68 Sorting new 40 Speed audit data readout 67 Standard operation select 73 Start button Output device 66 Printer 66 Summary Chapter 7 Manual 7 Switches Select Battery mains operation 73 Coin group 36 Symbols in the text 7 System time audit module 63 Crane Co Company INDEX T Text conventions 7 Time date audit module 63 Token value 70 Tube Coins Maximum number 32 Min number security stock 38 New 40 Combination For tube empty 43 New 40 Counter correction automatic 18 Counters Automatic programming 17 Correct to zero 19 Empty message when 43 U User interfaces c2 9 W Wake up time battery operation 74 white c2 9 Write protection for BDV VMC 75 83
9. You want to enter submenu LIMITATIONS 5 1x You enter the submenu 6 until Change limit You want to set the change limitation 7 E 1x Now you can set the function 8 BA until required digit You highlight the digit to be set 9 Ade until required value This value is to be set 42 10 Please repeat steps 8 and 9 to set the other digits of the change limitation if necessary You lock the set change limitation in 11 Ee memory You return to main menu operating 12 177 mode National Rejectors Inc GmbH Buxtehude LU c Configuration CHANGE PAYOUT Configuring conditions for tube empty message only c BDV Executive The lowest filling level sensor empty sensor signals that a tube is empty When you want the vending machine to display tube empty Le which tube s is are to be empty in order that the empty message is displayed you may specify depending on the tube coins The following coding scheme can be configured Code 00 Tube empty if tube M or M or tubes M and M empty Code 01 Tube empty if tubes M _ empty Code 02 Tube empty if tubes M _ empty Code 03 Tube empty if tubes M _ empty Code 04 Tube empty if tubes M and M empty Code 05 Tube empty if tubes M and M or tube M empty Code 06 Tube empty if tube M or M or M empty Code 07 Tube empty if tube M or M empty Code 08 Tube empty if tube M empty Code 09 Tube empty if tube M empty Code 10 Tube
10. also configure the individual tube coins You want to enter submenu Coin A Gei SORTING B E until New payout You want to configure the tube coins ER combination individually C 1x Now you can configure the tube coins You want to set a new coin value for D PE until required tube PE 1x Now you can enter a value F D j S i until required digit You highlight the digit to be set G Tele until required value This value is to be set H Please repeat steps F and G to set the other digits of the coin value if necessary You lock the set tube coin value in I 1x memory J Please repeat steps D to to set the tube values of the other tubes if necessary 10 ixx You return to main menu operating K mode CiD National Rejectors Inc GmbH Buxtehude 41 Crane Co Company CHANGE PAYOUT c Configuration Limiting change return only c BDV Executive You have the possibility to define a maximum residual amount that the changer is supposed to pay out to the customer at most The customer must then purchase enough during one vending operation so that the residual credit is less than the set change limitation To configure the change limitation Quick approach Main menu gt Ke Settings Operating modes z Limitations Change Limit Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 TX required menu item has already been selected 3 1x You enter submenu OPERATING MODES 4 until Limitations
11. by inserting the tube coins with the cassette installed you also have to activate the float up function see section Activating deactivating float up function in this chapter If the coin cassette is going to be removed to be refilled directly you have to activate the automatic tube counter programming see section Setting tube counters to float levels automatically in this chapter Specifying float level per tube To specify the float levels Quick approach Main menu gt E Settings gt Coin settings gt Float level How often Effect Ziel 1 1x You enter the main menu 2 1x You enter the SETTING menu 3 Deet steiere ee to enter submenu Coin 4 1 x You enter the submenu 5 until Float level You want to enter submenu FLOAT LEVEL 6 1 x You enter the submenu 7 Ge intii tube desired oo to set a float level for this 8 E Noe you can set a float level for this 9 oe until required digit You highlight the digit to be set 10 elle until required value This value is to be set 11 Please repeat steps 9 and 10 to set the other two digits of the float level if necessary 12 1x You lock the set float level in memory 13 Please repeat steps 7 to 12 to set the float levels of the other tubes if necessary 14 4 x 2 x Mee to main menu operating CiD National Rejectors Inc GmbH Buxtehude 15 Crane Co Company SETTINGS FOR FILLING AND EMPTYING CASSETTE Activating deactivating float up function You should activate the float up function if t
12. cassette e Limiting change return only c BDV Executive e Configuring conditions for tube empty message only c BDV Executive e Activating low power single motor payout Reassigning coin cassette If you exchanged the change tubes or coin cassette in order to be able to pay out other or more coins the new sorting must be set in the coin changer The coin changer comes with pre programmed coin cassette combinations which can be selected depending on the new sorting Ifthe new tube combination is not part of the pre programmed combinations it may be configured manually AO National Rejectors Inc GmbH Buxtehude LU c Configuration CHANGE PAYOUT To select a new tube combination Quick approach Main menu gt E Settings gt Coin settings gt Coin sorting gt Select tube cassette Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu You want to enter submenu Coin 3 until Coin settings Sones 4 1x You enter the submenu You want to enter submenu Coin 5 until Coin sorting SORTING 6 E You enter the submenu The required menu item has already been selected You want to select a new pre 7 Se programmed tube combination This tube combination matches until required tube combination your new coin cassette and is to be configured MI 00 g amp B 1x You lock the setting in memory In case none of the tube combinations suggested fits the new coin cassette you may
13. differ in their user interface The c blue is the only model with a user interface allowing a direct configuration at the coin changer All other models green orange white must be connected to the HENRI setting module for configuration that cannot be carried out using the switching block on the rear of the coin validator When to use the HENRI setting module Crane Co Company e To configure the c green orange white e To configure a second currency special token values in the c blue green orange white e As data transfer unit for e g current configuration and firmware files which are supposed to be loaded into a c blue green orange white GENERAL INFORMATION c Configuration Connecting HENRI In the HENRI short reference guide you learn how to connect the HENRI setting module to the currenza c with full details At this point you will only find a short description for on site configurations Plug the RJ 45 connector of the HENRI connecting cable into the top right socket of the coin changer Fig 1 Connecting HENRI HENRI is powered by the vending machine switches over to the c mode automatically and shows the vending machine display in normal operating mode e g the current change stock connected to the coin changers c green orange white for configuration and shall not be explained again EF In the following chapters it has been assumed that HENRI needs to be 10 National Rejectors
14. inventory keys disabling enabling inventory keys using MDB BDV protocol only c blue green During normal operating mode as well as in the Inventory menu the coin changer keysA B C D E and F are used as inventory keys When operating the inventory keys the coin changer pays out coins from the corresponding change tube A B C D E or F You may configure the coin changer so that the inventory keys are e enabled e disabled or e enabled disabled by the VMC To disable enable the inventory keys Quick approach 22 Main menu gt E Settings gt Operating modes gt Configure inventory keys Press key How often Effect 1 1x You enter the main menu You enter the Settinc menu The 2 1x required menu item has already been selected You enter submenu OPERATING MODES 3 1x The required menu item has already been selected 4 E You want to enable disable the INVENTORY KEYS You want the keys to be disabled 5 until setting desired enabled controlled by the VMC 6 d You lock the setting in memo g ry You return to main menu operating 7 1 x 2 x mode National Rejectors Inc GmbH Buxtehude LU c Configuration PRICES AND VENDING MODES ONLY c BDV ExECUTIVE 5 Prices and vending modes only c BDV Executive RH This BDV amp Executive chapter describes how to e hold the prices in the coin changer e configure Committed to vend or change return at any time e configure single or multi vend e reset or store c
15. operating 10 1x 2x Se 52 National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL Paying out all banknotes compensating the machine s security stock only c MDB Some vending machines particularly in the USA keep a security stock of coins in the tubes As the machine handles banknotes available for payout like tube coins not all of the banknotes can be payed out as change If you want the vending machine to pay out all banknotes you can compensate the security stock For security stock details cp section Preventing coins from getting stuck in the tubes in Chap 6 Cash acceptance To compensate the security stock Quick approach Main menu gt E Settings gt Peripheral gt Bll recycler gt Empty recycler store Press key How often Effect 1 1x You enter the main menu 2 flex You enter the SETTING menu 3 until Peripheral You want to enter submenu PERIPHERAL You enter the submenu The correct 4 E menu item has already been selected 5 1x You enter submenu RECYCLER 6 until Empty recycler You want the recycler to pay out all store banknotes keep at least 3 banknotes 7 1x Now you can set the function You want to activate deactivate the 8 Ad e until setting desired nction 9 1 x You lock the setting in memory 10 ie You return to main menu operating Crane Co Company mode 53 PERIPHERAL c Configuration Bill validator settings only c BDV Executive You may connect an MDB bill valid
16. rejected reliably you may assign a normal narrow or very narrow smallest acceptance tolerances acceptance band Es To select the acceptance tolerances Narrow and very narrow acceptance bands possess aloweracceptance rate of genuine coins Quick approach Main menu gt E Settings gt Coin settings gt Security level Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu 3 Unt Goin settings ae to enter submenu Coin 4 1x You enter the submenu 5 until eerste Tevel You want to specify a coin s y acceptance tolerances 6 1x Now you select the coin E ee You want to select a NORMAL NARROW until coin with problematic 7 acceptance See NARROW acceptance band for this Ix Now you can select the acceptance band 9 until acceptance band width You want the coin to be accepted in desired this band width 10 1x You lock the setting in memory 11 4 x 2 x You return to main menu operating Crane Co Company mode 35 CASH ACCEPTANCE c Configuration Selecting coin group Aor B The coins porgrammed in the coin changer may have been assigned to two coin groups A or B at the manufacturer e g to differentiate between two currencies IS currency coin goup A 2 currency coin group B In future you can modify the coin group setting using the configuration software currenza heartbeat cp separate heartbeat manual These two coin groups can be selected using the switching block on th
17. the configuration of the coin changer connected to be saved for batch configuration in HENRI LA el el S Data is being transferred to HENRI Following the 100 display message om GE x lt You enter submenu CLone again Transferring desired configuration to coin changers First of all connect the HENRI setting module to the coin changer to be configured with the clone see section Connecting HENRI in Chap 2 General information Quick approach HENRI main menu gt Extended functions gt Clone gt HENRI gt c Press key How often Effect 1 1x You enter the HENRI main menu You enter submenu EXTENDED FUNCTIONS You want the c configuration stored 1x in HENRI to be transferred to the coin changer connected N bo a z The stored configuration file s is are displayed A al sel SCH x lt Data is being transferred to the coin changer Following the 100 display message O co wb x lt x lt H Sp E N x lt You enter submenu CLone again You enter the HENR main menu again You return to the c operating mode c 8 1 x 2 x main menu Please repeat cloning for all coin changers to be configured CiD National Rejectors Inc GmbH Buxtehude ez Crane Co Company BATCH CONFIGURATION c Configuration Adapting individual settings Finally we recommend random checks of the data cloned and that individual settings of the changers or the coin and currency data is adapte
18. token values are configured using the setting menu cp separate service manual First of all the HENRI setting module must be connected to the coin changer see section Connecting HENRI in Chap 2 General information To set an alternative coin value Quick approach HENRI main menu gt Extended functions gt EI Channels Press key How often Effect 1 1x You enter the HENRI main menu 2 TX You enter submenu EXTENDED FUNCTIONS You want to set an alternative coin 3 E um value 4 Ad ed until required coin coin You highlight the coin an alternative QE channel value is to be set for Now you can set change the 5 GE ALTERNATIVE VALUE 6 Tele until required digit You highlight the digit to be changed 7 Ade until required value This value is to be set 8 Please repeat steps 6 and 7 to set the other digits of the alternative value if necessary You lock the set alternative value in the 9 1x HENRI memory You want to store the set alternative 10 S value in the coin changer You lock the set alternative value in the 11 ES coin changer memory 12 xX You enter the HENRI main menu again 13 4 ali x You return to the c operating mode c main menu 70 National Rejectors Inc GmbH Buxtehude LU c Configuration BASIC SETTINGS Changing currency calling code only c MDB The numeric currency code ISO 4217 which can be sent e g for the VMC dialogue language is set to the main currency on delivery Please use the l
19. want only tube coins also cash box filling mode coins to be accepted 5 1x Now you can set the function In tube filling mode you want only 6 PE until setting desired tube coins also cash box coins to be accepted 7 1x You lock the setting in memory You return to main menu operating 8 1 x 2 x BE 20 National Rejectors Inc GmbH Buxtehude LU c Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE Reporting inserted coins to machine only c MDB If you replenish change by inserting the tube coins in the tube filling mode and if you want the machine to count the coins inserted and display them for checking purposes the coin changer may transfer a filling report to the machine To activate deactivate the filling report function Effect You enter the main menu You enter the SETTING menu The required menu item has already been selected You enter submenu OPERATING MODES You want the machine to receive not receive a filling report Now you can set the function You want the changer to transfer not transfer a filling report You lock the setting in memory Quick approach Main menu z E Settings gt Operating modes gt Manual fill report Press key How often 1 1 x 2 1x 3 E 1x 4 until Manual fill report 5 1x 6 elle until setting desired 7 e 1x 8 1 x 2 x Crane Co Company You return to main menu operating mode 21 SETTINGS FOR FILLING AND EMPTYING CASSETTE c Configuration Disabling enabling
20. with MDB BDV card reader The following card systems may be connected to the coin changer e BDV card system e MDB card system standard address e MDB card system address 0x60 To activate the communication between coin changer and card reader Quick approach Main menu gt E Settings gt Peripheral gt Cashless gt BDV cashless MDB cashless standard addr MDB cashless address 0x60 Press key How often Effect 1x You enter the main menu 1X You enter the SETTING menu until Peripheral You want to enter submenu PERIPHERAL You enter the submenu The required 1x menu item has already been selected 1x You enter submenu CASHLESS OH A W N me ae ee a a gel al You want to set up the communication with a BDV MDB card system until card reader connected standard address MDB card system On al address 0x60 7 1x Now you can set up communication You want the communication to be LN eie a Active Not ACTIVE E 1x You lock the setting in memory You return to main menu operating 10 1 x 2 x eg 56 National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL Activating second price list for card transactions You can divide the up to 100 prices into 2 x 50 prices The first price list prices 1 50 is valid without any card inserted for cash sales and the second price list prices 51 100 is valid with a card inserted for card payment To activate deactivate the second price
21. 1x 3 until Peripheral 4 1x 5 until Bill recycler 6 1x 7 elle until setting desired 8 1x 9 1 x 2 x Crane Co Company You return to main menu operating mode 51 PERIPHERAL c Configuration Inhibiting high value banknotes depending on change stock only c MDB If a CashCode recycler is conntected to an MDB coin changer you can inhibit the acceptance of high value banknotes if there is not enough change l e before each sale the coin changer decides which banknote can be accepted and which cannot be accepted depending on the current change stock in the coin cassette and recycler amp This setting is intended for applications in vending machines which do not support this function To limit the banknote acceptance Quick approach Main menu gt E Settings gt Peripheral gt Bill recycler gt Inhibit bill acceptance Press key How often Effect 1x You enter the main menu x You enter the SETTING menu until Peripheral You want to enter submenu PERIPHERAL Tx You enter the submenu The required menu item has already been selected 1x You enter submenu RECYCLER You want high value banknotes to be inhibited always be accepted depending on the change unii nnioit DIII accepeance Oo oO A W N e Wl Tei Ia ei fei la LU E J H J H 1x Now you can set the function until setting desired You want to activate not activate the M GO N al function 1x You lock the setting in memory You return to main menu
22. Company PRICES AND VENDING MODES ONLY c BDV EXxECUuTIVE c Configuration Configuring single or multi vend In principle the customer can purchase a number of products one after the other once he has inserted his money multi vend The change is not paid out until the customer has operated the return lever However the coin changer can also be setto single vena i e the customer can only insert coins until the value of the highest set price is reached Change is then paid out automatically after each vend To set single or multi vend Quick approach Main menu gt E Settings gt Operating modes gt Selling mode gt Single Multi vend Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 d required menu item has already been selected 3 1x You enter submenu OPERATING MODES You want to enter submenu SELLING 4 until Selling mode OBE You enter the submenu The required 5 1X menu item has already been selected 6 dee You want to set SINGLE or MULTI VEND 7 Ad ed until setting desired Single or multi vend is to be activated 8 1x You lock the setting in memory 9 4 x 2 x You return to main menu operating mode 28 National Rejectors Inc GmbH Buxtehude LU c Configuration PRICES AND VENDING MODES ONLY c BDV ExECUTIVE Resetting or storing credit which cannot be paid out If the remaining credit cannot be paid out of the coin cassette or connected hoppers or recyclers
23. Inc GmbH Buxtehude LU c Configuration 3 Presettings PRESETTINGS lt gt This chapter describes settings which are not concerned with the coin changer operation itself but must be carried out once before configuring the coin changer if not set at NRI Menu language Display contrast Display message Selecting menu language The c supports the following languages English German French option Italian option Spanish option and is provided with three installed languages The third language is customised If required the coin changer may also be provided with other languages than listed above To select the menu language also language for audit receipts Quick approach Effect You enter the main menu You enter the SETTING menu You want to enter submenu OTHER SETTINGS You enter the submenu You want to set the menu LANGUAGE Now you can set the LANGUAGE You want to set this language You lock the language selected in memory Main menu gt E Settings gt Other settings gt Language Press key How often 1 1 x 2 1 x 3 until Other settings 4 1x 5 1x 6 e Tx 7 Tele until language desired 8 1X 9 1 x 2 x Grane Co Company You return to main menu operating mode 11 PRESETTINGS c Configuration Setting display contrast only c blue The contrast of the c blue display has a default setting of 46 To change the contrast Quick approach Main menu gt E Settings
24. NRI into the remaining changers to be configured Only the data that applies to the coin changer will be stored and transmitted but not the data saved in the coin validator or peripheral equipment The following settings remain unaffected and may need to be adapted in addition e Coin and currency data e Acceptance bands and coin values Please note that whenever you are copying coin changer data A N from older devices with a smaller range of functions and load this data into a new device the new functions may need to be adapted if necessary In the opposite case an older device will also not be provided with the additional functions of the new device Configuring coin changer master 76 If you haven t done so already first of all you have to configure a coin changer so that its configuration can be used as clone for the other coin changers to be configured see Chap 3 Presettings to Chap 10 Basic settings National Rejectors Inc GmbH Buxtehude LU c Configuration BATCH CONFIGURATION Storing desired configuration in HENRI First of all connect the HENRI setting module to the coin changer with the configuration to be cloned see section Connecting HENRI in Chap 2 General information Quick approach HENRI main menu gt Extended functions gt Clone gt c gt HENRI Press key How often Effect 1 1x You enter the HENRI main menu 1x You enter submenu EXTENDED FUNCTIONS N You want
25. Rejectors Inc GmbH Buxtehude LU c Configuration AUDIT Setting date and time In order to be able to print or read out the audit data with date and time you have to set the system time Quick approach Main menu gt E Settings gt Audit module gt Set system date time Press key How often Effect 1 1x You enter the main menu 2 x You enter the SETTING menu 3 intl Mees weenie eter teal to enter submenu Ap 4 1X You enter the submenu 5 until Set system date You want to set the SYSTEM DATE 6 1X Now you can set the date 7 oe until required digit You highlight the digit to be changed 8 elle until required value This value is to be set 9 Please repeat steps 7 and 8 to set the other digits of the date if necessary 10 1x You lock the set date in memory 11 Press ey and repeat steps 5 to 10 to set the time You return to main menu operating 12 1 x 2 x ene CiD National Rejectors Inc GmbH Buxtehude 63 Crane Co Company AUDIT Specifying data to be printed c Configuration For the printout of audit data you can set the following e Printing Not printing time e Printing Not printing product price specific audit data e Printing Not printing tube and cash box sales data EX Presettings To specify data to be printed Quick approach Main menu gt E Product specific data Sales data Press key 1 2 3 4 5 6 d 10 11 64 How often 1x 1x until Audit module lx until Configu
26. Technical Documentation A Crane Co Company d a e Brech Coin changer currenza tz Manual for configuration 08 11 Schn JMo Roe Version 1 1 HB C2K EN CRANE Crane Payment Solutions GmbH Zum Fruchthof Ge D 21614 Buxtehude el Phone 49 0 41 61 729 0 Fax 49 0 41 61 729 115 E mail info craneps com www craneps com c Configuration TABLE OF CONTENT Tabel of contents 1 About this manual H Text conventions Additional technical documentation 8 2 General information 9 The vending machine interfaces 9 The user interfaces 9 When to use the HENRI setting module 9 Connecting HENRI 10 3 Presettings 11 Selecting menu language 11 Setting display contrast only c blue 12 Specifying display message for operating mode only c blue 13 4 Settings for filling and emptying cassette 14 Which settings should be done 14 Settings for tube refilling by coin insertion 14 Settings for direct refilling the removed cassette 14 Configuring float levels 15 Specifying float level per tube 15 Activating deactivating float up function 16 Setting tube counters to float levels automatically 17 Correcting tube counters according to filling level sensors 18 Resetting tube counters before fill up 19 Redirecting cash box coins to return area 20 Reporting inserted coins to machine only c MDB 21 Disabling enabling inventory keys disabling enabling inventory keys using MDB BDV protocol only c blu
27. To activate deactivate the tube counter reset Quick approach Main menu gt EF settings gt Operating modes z Tube counters sorrest __ 9_Zer9 Press key How often Effect 1 1x You enter the main menu You enter the SeTtTiNG menu The 2 AEX required menu item has already been selected 1x You enter submenu OPERATING MODES 4 until Tube counters You want the TuBE CounTERs to be H Correct CO Zero reset ignored 5 1x Now you can set the function 6 PE until setting desired 7 1x 8 1 x 2 x Crane Co Company You want the tube counters to be reset ignored when removing the coin cassette You lock the setting in memory You return to main menu operating mode 19 SETTINGS FOR FILLING AND EMPTYING CASSETTE c Configuration Redirecting cash box coins to return area If you replenish change by inserting coins and if you do not want the cash box coins to be accepted but only the tube coins the coin changer can be set so that all cash box coins will be inhibited and redirected to the return area when the changer is in tube filling mode To disable enable the cash box coins when refilling the coin cassette Quick approach Main menu gt EF settings gt Operating modes gt z Only tube Goipne gp Dino mode Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 ix required menu item has already been selected 1x You enter submenu OPERATING MODES 4 until Only tube coins in You
28. ast three digits of the 4 digit input field to set the 3 digit currency code The first digitis not part of the currency code and must be set fo 1 Example euro currency code 978 gt input 1978 For more information on the currency code please refer to the MDB specification NAMA document MDB ICP 2 0 www vending org Some vending machines ask for the international country calling code and not for the currency code ITU E 164 e g 0033 for France cp vending machine manual To change the currency calling code Quick approach Main menu gt _E_ settings gt Other_settings gt Surrensy_scode Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu 3 until ther settings H to enter submenu OTHER 4 1x You enter the submenu 5 until Currency code You want to change the CURRENCY CODE 6 FX Now you can change the code 7 oe until required digit You highlight the digit to be changed 8 elle until required value This value is to be set 9 Please repeat steps 7 and 8 to set the other digits of the currency code if necessary 10 1x You lock the set code in memory 11 ixx You return to main menu operating Crane Co Company mode 71 BASIC SETTINGS Changing MDB level only c MDB Quick approach 72 c Configuration In cases the coin changer is supposed to communicate as MDB level 2 instead of MDB level 3 changer Main menu gt E Settings gt Other settings gt MDB l
29. ator to the coin changer Please consider the following coin changer settings for communication between both devices Communication set up only c BDV Executive No acceptance of banknotes when machine displays Tube empty only c BDV Executive e Acceptance of banknotes only for card payments only c BDV Executive Setting up communication with MDB bill validator Quick approach 54 To activate the communication between coin changer and MDB bill validator Main menu zs Ke Settings Peripheral z _ Bill walidator gt BIL validator M DD N BO OU fF OO WM r O Press key a8 Seg L L ES a ES a d How often 1 x eX until Peripheral lex until Bill validator oe 1x until setting desired 1x 1 x 2 x Effect You enter the main menu You enter the SETTING menu You want to enter submenu PERIPHERAL You enter the submenu You want to enter submenu But VALIDATOR You enter the submenu The required menu item has already been selected Now you can set up the communication with the bill validator You want the communication to be ActivE NotT ACTIVE You lock the setting in memory You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL Inhibiting releasing banknote acceptance depending on change stock or card payments e Inhibiting banknote acceptance if machine displays Tube empty If the coin cassette has a s
30. ction of the tube counters you must deactivate this function If the tube counter correction is deactivated ensure that the tubes are emptied either using the inventory keys or the service menu Otherwise the tube counters do not equal zero before refilling the tubes but the number of coins registered before emptying the tubes cp Separate service manual To activate deactivate the tube counter correction Quick approach Main menu zs Ke Gettinge _operating_mnodes_ gt Tube counter correction Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 1x required menu item has already been selected 1x You enter submenu OPERATING MODES 4 until Tube counter You want to activate deactivate the Correction TUBE COUNTER CORRECTION Now you can activate deactivate the 5 1x TUBE COUNTER CORRECTION 18 You want the tube counters to be 6 elle until setting desired corrected not corrected according to filling level sensors 7 1x You lock the setting in memory You return to main menu operating 8 ES ECH National Rejectors Inc GmbH Buxtehude LU c Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE Resetting tube counters before fill up If change is refilled by inserting the tube coins but the cassette is removed to be completely emptied before fill up the coin changer should be set so that the tube counters will be reset when removing the cassette i e before refilling the tubes
31. d if necessary 73 National Rejectors Inc GmbH Buxtehude LU c Configuration 12 Index 2 price lists with cashless 57 12 24 character printout audit module 65 A Acceptance Band select 35 Limit See Acceptance limitation Limitation 31 Tube coins 32 Tolerances select 35 Active level hopper payout empty signal 49 Alternative coin value 70 Attention 7 Audit 61 Module internal 61 Date time 63 Max IrDA readout speed 67 Output device 65 With without start button 66 Printing format 65 Vending machine number 61 Which data is to be printed 64 Unit In the machine 60 Set up communication 60 Automatic tube counter Correction 18 Programming 17 B Banknote Acceptance Inhibit When there is not enough change 52 55 With card payment 55 Limit 31 Recycler See Recycler Banknotes payout all 53 Base value See Smallest coin value Basic settings 68 Crane Co Company INDEX Batch configuration 76 Battery operation Save current 45 Select 73 Wake up time 74 BDV card system 56 Bill Acceptance See Banknote acceptance Recycler See Recycler Validator 54 Inhibit banknote acceptance 55 Set up communication 54 blue c2 9 c2 9 Brightness display 12 C c2 Machine interfaces 9 User interfaces 9 Calling code 71 Card charging limit 58 Card reader 56 2 price lists with cashless 57 Initialise after sales 59 Limit card recharging 58 Set up communication 56 Cashbox 13 Cash box coins inhibit in fil
32. e rear of the coin validator in order that the coin changer accepts either coin group Aor B 1 Turn machine s power off 2 Unlatch coin validator and remove it from the changer see Fig 2 A amp B Fig 2 Removing and reinstalling coin validator 36 National Rejectors Inc GmbH Buxtehude LU c Configuration CASH ACCEPTANCE 3 Use DIL switch 10 to select coin group A or B see Fig 3 Coin group B Coin groupA Fig 3 Selecting coin group 4 Reinsert coin validator until it clicks in position see Fig 2 B amp C D Turn power on 6 Turn power off and on again iil National Rejectors Inc GmbH Buxtehude SR Crane Co Company CASH ACCEPTANCE c Configuration Preventing coins from getting stuck in the tubes If a security stock is configured for the individual change tubes the changer does not pay out a minimum number of tube coins For coins that cause problems during stacking and tend to stand amp upright instead of lying flat a relatively high setting for the security Stock should be selected since the coins will no longer spring back and stand upright when they fall onto a higher stack of coins In case there is no setting entry 00 the security stock is set to 3 automatically MDB changers can also be set so that the configured security stock can be paid out by the vending machine and the security stock can also be transmitted to the vending machine whenever the machine
33. e green 22 Crane Co Company TABLE OF CONTENTS c Configuration 5 Prices and vending modes only c BDV Executive 23 Price holding in the coin changer 23 Setting prices 24 Activating coin changer price holding 25 Displaying price 26 Configuring Committed to vend or change return at any time 27 Configuring single or multi vend 28 Resetting or storing credit which cannot be paid out 29 6 Cash acceptance 30 Limiting acceptance of coins and banknotes only c BDV Executive 31 Limiting acceptance of tube coins filling level limitation 32 Inhibiting coins 33 Inhibiting high value coins if there is not enough change only c BDV Executive 34 Optimising acceptance of genuine coins rejection of fraud coins defining acceptance tolerances 35 Selecting coin group A or B 36 Preventing coins from getting stuck in the tubes 38 Configuring security stock for each tube 38 Transmitting tube filling level incl security stock to VMC only c MDB 39 Enabling VMC to payout security stock with DISPENSE only c MDB 39 7 Change payout 40 Reassigning coin cassette 40 Limiting change return only c BDV Executive 42 Configuring conditions for tube empty message only c BDV Executive 43 Activating low power single motor payout 45 4 National Rejectors Inc GmbH Buxtehude LU c Configuration TABLE OF CONTENT 8 Peripheral Hopper settings Setting hopper coins Setting up communication with hopper s Specifying active levels of the ho
34. e up time if necessary 10 flex You lock the set time in memory 11 4 x 2 x Nk to main menu operating 74 National Rejectors Inc GmbH Buxtehude LU c Configuration BASIC SETTINGS Providing coin changer configuration with write protection for BDV machines only c BDV You may provide the configuration data of the coin changer with a write protection in order that it cannot be overwritten by the BDV vending machine control To activate deactivate the write protection Effect You enter the main menu You enter the SETTING menu The required menu item has already been selected You enter submenu OPERATING MODES You want the write protection to be Active Not ACTIVE Now you can set the function The c configuration is not to be overwritten may be overwritten You lock the setting in memory You return to main menu operating Quick approach Main menu gt BE _settings _op eratings_modes_ gt Nrite_ orotection for BDV YMC Press key How often 1 1x 2 1 x 3 1 x 4 until Write protection For DY VME 5 B 1x 6 until setting desired 7 1x 8 1 x 2 x Crane Co Company mode 19 BATCH CONFIGURATION c Configuration 11 Batch configuration If the same settings are to be made for several coin changers of the same series it is sufficient to 1 configure one changer as required 2 save this state of settings in the HENRI setting module and then 3 transmit the state of settings from HE
35. ed in such a way that 68 values and prices must be changed and adapted accordingly National Rejectors Inc GmbH Buxtehude LU c Configuration To change the smallest coin value BASIC SETTINGS Quick approach Main menu zs Ke Gettinge Other settings Base Coin value Press key How often Effect 1 1x You enter the main menu 2 Es You enter the SETTING menu i You want to enter submenu OTHER 3 until Other settings SCENE You enter the submenu The required 4 Des menu point is already selected You want to change the smallest coin 5 ue value BASE COIN VALUE 6 oe until required digit You highlight the digit to be changed 7 elle until required value This value is to be set 8 Please repeat steps 6 and 7 to set the other three digits of the smallest coin value if necessary 9 1 x You lock the set value in memory 10 qos You return to main menu operating Crane Co Company mode 69 BASIC SETTINGS c Configuration Configuring alternative coin value for second currency or as token value With the alternative coin value you may specify on the one hand the coin value of a second currency and on the other hand the value for a token Configuring an alternative coin value invalidates the real coin value The alternative coin value is only used as token value if the vending amp machine cannot identify the token ID coming from the coin changer The alternative coin value does not report a token but a coin Conventional
36. empty if tube M empty Code 11 Tube empty if tube M empty Code 12 Tube empty if tube M empty Code 13 Tube empty if tube M empty Code 14 Tube empty if tubes M empty Code 15 Tube empty if tubes M and M empty M Tube coin with lowest value M Tube coin with highest value CiD National Rejectors Inc GmbH Buxtehude 43 Crane Co Company CHANGE PAYOUT To configure the tube empty code c Configuration Quick approach Main menu gt E Settings gt Coin settings gt Condition for tube empty Press key How often Effect 1 1x You enter the main menu 2 ds You enter the SETTING menu You want to enter submenu Coin 3 until Coin settings cence 4 1x You enter the submenu until Condition for tube You want to configure a tube empty 5 empty code Now you can set the function cp table 6 E above 7 D e until required digit You highlight the digit to be set 8 until required value This value is to be set 9 Please repeat steps 7 and 8 to set the second digit of the code if necessary 10 1X You lock the set code in memory You return to main menu operating 11 1 x 2 x mode 44 National Rejectors Inc GmbH Buxtehude LU c Configuration CHANGE PAYOUT Activating low power single motor payout If you want the coin changer to use as less electricity as possible e g in battery operation it may use only one motor instead of all motors at the same time when paying out coins T
37. ered exactly in the tube filling mode Whereas if you remove and completely empty the cassette before inserting the tube coins you should set the following in order to reset the tube counters before refilling the cassette e Resetting the tube counters before refilling the cassette e Correcting tube counters according to filling level sensors automatically Settings for direct refilling the removed cassette If the cassette is removed to be directly refilled with a certain number of coins per tube i e counted coins the coin changer must be set as follows to ensure the exact registration of the coin number e Configuration of the coin number as float level per tube e Automatic tube counter setting to float levels e Deactivation of the automatic tube counter correction according to filling level sensors Ifthe cassette is removed to be directly refilled with any number of coins the tube counters must be corrected according to filling level sensors automatically 14 National Rejectors Inc GmbH Buxtehude LU c Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE Configuring float levels Should you wish the service personal to always fill or empty the tubes at a filling level of a certain and always identical coin number it is advisable to configure so called float levels First of all specify a number of coins for each change tube see section Specifying float level per tube in this chapter Ifthe tubes are refilled
38. evel MO AN BO OF Lh W N r Press key How often 1x KS until Other settings 1 x until MDB level TX until required level TX 1 x 2 x Effect You enter the main menu You enter the SETTING menu You want to enter submenu OTHER SETTINGS You enter the submenu You want to change the MDB LeveL Now you can change the level This level is to be set You lock the selected MDB level in memory You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration BASIC SETTINGS Selecting mains operation or battery operation only c MDB Depending on the installation site MDB coin changers equipped with a battery and a wake up line can always be switched to mains or battery operation For this the changer has two DIL switches accessible when removing the coin cassette gt f degen _ _ lt lem a TS Fig 4 Removing and reinstalling coin cassette 1 Remove coin cassette Pull latch Fig 4 A Pull cassette straight out of the housing guides to the front Fig 4 B 2For standard mains operation use a pointed object to push the two DIL switches upward to STAN ON DARD for battery operation SC a Standard downward to Battery see a 1 2 Fig 5 and markings on the al ae coin changer housing J i bb Battery Fig 5 Switches for mains battery operation iil National Rejectors Inc GmbH B
39. ey changer and inserted cash is returned whenever you want the coin changer can be set up so that change is only paid out after a vending operation If the changer is not set to Committed to vend the customer at any time can cause the return of the residual credit by pressing the return button even without having pressed a selection button or bought something In addition a maximum amount of money which is allowed to be amp accepted at most for a transaction can be configured see section Limiting acceptance of coins and banknotes only c BDV Executive in Chap 6 Cash acceptance To activate deactivate Committed to vend Quick approach Main menu gt FE Settings gt Operating modes gt Selling mode gt Committed to vend Press key How often Effect 1 1x You enter the main menu You enter the SETTING menu The 2 1x required menu item has already been selected 3 1x You enter submenu OPERATING MODES You want to enter submenu SELLING until Selling mode OnE 1x You enter the submenu You want do not want the customer until Committed to vend to buy something before he can claim back the change A bel Tel fei el Te Fk S FS EF Jj H 7 1 x Now you can set the function You want to activate deactivate the Ad ed EE Committed to vend function 9 1x You lock the setting in memory You return to main menu operating 10 1 x 2 x neg CiD National Rejectors Inc GmbH Buxtehude 2 Grane Co
40. ger can decide which residual credit can no longer be paid out by the changer and must be paid out from the hoppers Beyond that the coin changer must know the active level low high of the coin payout and empty detection option signals National Rejectors Inc GmbH Buxtehude LU c Configuration Setting hopper coins PERIPHERAL To configure the value of the coins collected in the hopper s The hopper designations 1 4 refer to the connectors 1 4 on the amp hopper interface used to connect the hopper s to the coin changer cp separate manual for the hopper interface Hopper 1 e g iS connected using hopper connector 1 Main menu gt E Settings gt Peripheral gt Hopper gt Coin value in hopper 1 2 3 4 Quick approach Press key How often 1 1 x 2 1 x 3 until Peripheral ER IEX 5 until Hopper 6 1 x 7 SE value in 8 x 9 oe until required digit 10 PE until required value 11 12 1x 13 14 1 x 2 x Effect You enter the main menu You enter the SETTING menu You want to enter submenu PERIPHERAL You enter the submenu You want to enter submenu HOPPER You enter the submenu You want to set the value of the coins collected in hopper 1 Now you can set the value You highlight the digit to be set This value is to be set Please repeat steps 9 and 10 to set the other digits of the coin value if necessary You lock the set coin value in memory Press ey and repeat steps 7 to 12 to set furthe
41. he 9 PE until setting desired Kagepe 10 d You lock the setting in memory 11 BCE You return to main menu operating mode 25 PRICES AND VENDING MODES ONLY c BDV EXxECUTIVE c Configuration Displaying price If you want the machine to display the price of the product selected you have to adapt the coin changer configuration accordingly To display suppress the price Quick approach Main menu gt E Settings gt Operating modes gt Selling mode gt Price Holding gt Tndicate price of product 26 Press key How often Effect 1 1x You enter the main menu You enter the Setting menu The 2 1x required menu item has already been selected 3 1x You enter submenu OPERATING MODES Yi tt t b S 4 Untile Iing mede Eh o enter submenu SELLING 5 1x You enter the submenu You want to enter submenu PRICE 6 until Price Holding Er 7 1x You enter the submenu PRicE HOLDING 8 until Indicate price of You want the price of the product H Product selected to be displayed not displayed Now you can activate deactivate the 9 ES function You want the price to be displayed not 10 elle until setting desired displayed 11 1x You lock the setting in memory 12 EE You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration PRICES AND VENDING MODES ONLY c BDV ExECUTIVE Configuring Committed to vend or change return at any time To ensure that the vending machine is not used as a mon
42. he cassette is refilled by inserting the tube coins on site This makes sure that all tube coins being inserted c Configuration after the float level has been reached will be directed to the return area C If the float up function is activated but no float level configured float level for the single tubes 000 the tube will be filled until the optional 50 filling level sensor is covered or emptied until this sensor is no longer covered To activate deactivate the float up function Effect You enter the main menu You enter the SETTING menu The correct menu item has already been selected You enter submenu OPERATING MODES You want to activate deactivate the FLoat up function Now you can activate deactivate the FLoat up function You want to activate deactivate the function You lock the setting in memory Quick approach Main menu gt E Settings gt Operating modes gt Float up Press key How often 1 1 x 2 1x 3 1x 4 until Float up 5 d 6 Ade until setting desired 7 1x 8 1 x 2 x 16 You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE Setting tube counters to float levels automatically Activate this function if you remove the coin cassette to directly refill it with a certain number of coins float levels This is to ensure that the tube counters will be set to the float level coin number automat
43. here is not enough change only c MDB e Compensation of banknote security stock only c MDB To activate the communication between an MDB coin changer and a Main menu gt E Settings gt Peripheral gt Bill recycler gt Communication with recycler recycler Quick approach Press key How often 1 1x 2 d A until Peripheral 4 Tx 5 1x 6 ES 7 elle until setting desired 8 1X 9 1 x 2 x 50 Effect You enter the main menu You enter the SETTING menu You want to enter submenu PERIPHERAL You enter the submenu The required menu item has already been selected You enter submenu BILL RECYCLER The required menu item has already been selected Now you can set up the communication with the recycler You want the communication to be AcTIVE NOT ACTIVE You lock the setting in memory You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL To activate the communication between an BDV Executive coin changer and a recycler Effect You enter the main menu You enter the SETTING menu You want to enter submenu PERIPHERAL You enter the submenu You want to set up the communication with the recycler Now you can set up the communication You want the communication to be ActTIvE NotT ACTIVE You lock the setting in memory Quick approach Main menu gt E Settings gt Peripheral gt Bill recycler Press key How often 1 1 x 2
44. hortage of change and the machine displays Tube empty depending on conditions set the bill validator can be blocked automatically e Enabling bill validator for card payments only The bill validator can always be enabled or only if a card is inserted into a card reader connected To inhibit release the banknote acceptance Quick approach Main menu gt E Settings gt Peripheral gt Bill validator gt Enable bill acceptance Press key How often Effect 1x You enter the main menu 1x You enter the SETTING menu until Peripheral You want to enter submenu PERIPHERAL 1x You enter the submenu You want to enter submenu BILL until Bill validator ORATOR ES You enter the submenu until Enable bill You want to limit the acceptance of acceptance banknotes 18 Now you can set the function CON Oh A A W N e HS ES bei bel amp You want the machine to accept 9 until setting desired banknotes IF tubes are noT Empty a ai Carp is inserted ALways 10 1x You lock the setting in memory You return to main menu operating 11 e mode CiD National Rejectors Inc GmbH Buxtehude 59 Crane Co Company PERIPHERAL c Configuration Card reader settings only c BDV Executive lt gt This section describes how to set up communication between coin changer and MDB BDV card reader e activate a second price list for card payments e limit card charging e reinitialise the card reader after a sale Setting up communication
45. ically in the tube filling mode as soon as you remove the cassette from the coin changer To activate deactivate the automatic tube counter programming Quick approach Main menu zs Ke Gettinge Operating modes z Program tubs counters auton Press key How often Effect 1 1x You enter the main menu You enter the Gre menu The 2 1x correct menu item has already been selected 3 1x You enter submenu OPERATING MODES until Program tube You want to activate deactivate the 4 counte re auon function Now you can activate deactivate the 5 ZS function You want to activate deactivate the 6 PE until setting desired ARAN 7 E 1x You lock the setting in memory You return to main menu operating 8 1 x 2 x D CiD National Rejectors Inc GmbH Buxtehude 17 Crane Co Company SETTINGS FOR FILLING AND EMPTYING CASSETTE c Configuration Correcting tube counters according to filling level sensors Six tube counters are monitoring the exact number of coins in the tubes and register each coin collected by and paid out from the tubes In addition each tube is equipped with up to four filling level sensors If the coin changer is Supposed to compare the tube counter readings with the measured filling levels of the sensors after a coin has been accepted or paid out and correct the tube counters if necessary you should activate the automatic tube counter correction If the vending machine control is unable to process the automatic amp corre
46. ings SE A Le dex You enter the submenu ZE You want to set the DisPLay message 5 until Display for normal operating mode Now you can select the DisPLay 6 G 1x message 7 PE until required message You want to set this message You lock the message selected in 8 E Wes memory You return to main menu operating 9 1 x 2 x fede CiD National Rejectors Inc GmbH Buxtehude 13 Crane Co Company SETTINGS FOR FILLING AND EMPTYING CASSETTE c Configuration 4 Settings for filling and emptying cassette Test This chapter describes useful or required settings for refilling and emptying the coin cassette e Configuring float level e Setting tube counters to float level automatically e Correcting tube counters according to filling level sensors e Resetting tube counters before refilling cassette e Redirecting cash box coins to return area e Reporting inserted coins to machine only c MDB e Disabling enabling inventory keys disabling enabling inventory keys using MDB BDV protocol Which settings should be done To enable the coin changer to register the exact coin number we recommend the following settings depending on the filling method used Settings for tube refilling by coin insertion If the cassette is refilled by inserting the tube coins and without emptying the cassette completely beforehand see that the tube counters are not corrected according to the filling level sensors automatically as the inserted coins will be regist
47. it limit for You want to determine a credit 6 cashless limitation T E 1x Now you can set the function 8 Tele until required digit You highlight the digit to be set 9 Ade until required value This value is to be set 10 Please repeat steps 8 and 9 to set the other digits of the credit limitation if necessary f You lock the set credit limitation in 11 a memory You return to main menu operating 12 1 x 2 x GE 58 National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL Reinitialising card reader after each transaction Perhaps some of the older card systems have to be reinitialised after each transaction To activate deactivate the function Reinitialise card reader after each transaction Quick approach Main menu gt EF settings Operatins_modes_ gt _sellins_ mode gt CPlnew_start after vend Press key How often Effect 1 1x You enter the main menu You enter the Grrmwe menu The 2 1x required menu item has already been selected 3 1x You enter submenu OPERATING MODES l You want to enter submenu SELLING 4 until Selling mode MODE 5 B 1X You enter the submenu You want the connected card reader to 6 sees new start after bo jnitialised no longer initialised after EE each sale 7 e 1x Now you can set the function You want to activate deactivate the 8 Ade until setting desired nction 9 1x You lock the setting in memory You return to main menu operating 10 1 x 2 x Ee CiD National Rejectors
48. ling mode 20 Caution 7 Change 13 Limit 42 See Change limitation Limitation 42 Payout when 27 28 Reset 29 Store 29 Tubes Float level 15 17 New 40 Replenishment display 21 Security stock 38 19 INDEX Chapter summary 7 Charging cards limit 58 Clone coin changer configuration 76 Code tube empty message 43 Coding scheme tube empty message 43 Coin Acceptance Inhibit 33 If tube empty 34 Limit 31 Cassette Float level 15 17 New 40 Remove reinstall 73 Replenishment display 21 Security stock 38 Empty signal hopper 49 Group A B select 36 Stack problems 38 Validator remove reinstall 36 Value Alternative 70 In hopper 47 Coins Hopper 47 Inhibit 33 If tube empty 34 Comment 7 Committed to vend 27 Communication With bill validator set up 54 With card system set up 56 With external audit unit set up 60 With hopper set up 48 With recycler set up 50 Conditions for Tube empty 43 Configuration Clone 76 Save 75 Configure inventory keys 22 Connection 10 Contrast display 12 Conventions manual 7 80 c Configuration Correction automatic tube counters 18 CPC new start after vend 59 Credit Limit See Credit limitation Limitation 58 Currency Code 71 Select 36 currenza c2 blue green orange white 9 Machine interfaces 9 User interfaces 9 D Data acquisition device audit module 65 Date time data acquisition device 63 Debit card reader See Card reader Dialogue language 11 Machi
49. list Quick approach Main menu gt E Settings gt Operating modes gt Selling mode gt Price Holding gt 2 _ price Lists with cashless Crane Co Company Press key How often Effect 1 1x You enter the main menu You enter the Settinc menu The 2 1x correct menu item has already been selected 3 1x You enter submenu OPERATING MODES 4 Val ae er mode Ch to enter submenu SELLING 5 1x You enter the submenu 6 e a a lcsag d to enter submenu PRICE 7 1x You enter the submenu PRICE HOLDING 8 Ss EE EE 9 1 x Now you can set the function 10 To wutz desiree EE 11 1 x You lock the setting in memory 12 EE You return to main menu operating mode 5M PERIPHERAL c Configuration Limiting debit card recharging only for BDV MDB card readers In case a BDV or MDB card system is connected to the coin changer you may define a maximum credit with which debit cards can be charged amp If you do no longer want the customers to credit their debit cards you can configure a credit of 099 00 To configure a credit limitation Quick approach Main menu gt EB settings gt Operating modes gt bimitations gt _Credit limit for cashless Press key How often Effect 1 1 x You enter the main menu You enter the SETTING menu The 2 1x required menu item has already been selected 3 1x You enter submenu OPERATING MODES 4 ntil Limitations You want to enter submenu LIMITATIONS 5 1x You enter the submenu nl cred
50. ne control system 71 DIL switches Select battery mains operation 73 Select coin group 36 Disassembly assembly Coin cassette 73 Coin validator 36 Display Contrast 12 Message operating mode 13 Price 26 Texts 7 Disposal 7 Documentations additional 8 E Empty Payout signal hopper 49 Recycler store 53 Sensor 43 Environmental protection 7 External Audit unit 60 Devices 46 National Rejectors Inc GmbH Buxtehude LU c Configuration F Filling Display 21 Level Limitation 32 Sensors 18 Lowest empty sensor 43 Transmit to machine 21 Fill report 21 Float Level 15 17 up function 15 16 Format for printout audit module 65 Fraud coin rejection optimise 35 G General information Configuration 9 HENRI setting module 9 Manual 7 9 Settings for tube filling 14 Genuine coin acceptance optimise 35 green c2 9 Guide chapter 7 H Hazard 7 HENRI Connect 10 General information 9 Hopper 46 Active level payout empty signal 49 Coin values 47 Set up communication 48 Crane Co Company INDEX Indicate of price of product 26 Inhibit Banknote acceptance 55 Cash box coins in filling mode 20 Coin acceptance 33 If tube emtpy 34 High value banknotes 52 Keys 22 Initialise card reader 59 Instructions additional Additional 8 Interfaces c2 9 Introduction Configuration 9 HENRI setting module 9 Manual 7 9 Settings for tube filling 14 Inventory 13 Keys disable 22 IrDA high speed 67 K Ke
51. o activate deactivate the single motor payout Effect You enter the main menu You enter the SETTING menu The required menu item has already been selected You enter submenu OPERATING MODES You want to AcTIVATE DEACTIVATE the single motor payout Now you can set the function When paying out you want one all motors to be controlled You lock the setting in memory You return to main menu operating Quick approach Main menu gt E Settings gt Operating modes gt Simple payout Press key How often 1 1 x 2 11 3 1x 4 until Simple payout 5 1x 6 elle until setting desired 7 Ee 1x 8 1 x 2 x Crane Co Company mode 45 PERIPHERAL c Configuration Peripheral This chapter describes how to e set up communication between coin changer and peripherals connected e make settings on the coin changer in order to apply them to the peripherals You can make settings for the following peripheral devices e hoppers e recycler e bill validator e card reader e external audit unit Hopper settings 46 If a coin type is frequently paid out as change and the respective tube is often empty you can use an NRI hopper interface to connect up to four hoppers to the coin changer from which the vending machine can pay out coins on an alternative basis In the changer a setting must be made that one hopper or more hoppers are connected and which coin is being collected in the hopper so that the coin chan
52. ogue language cp section Selecting menu language in Chap 3 Presettings Setting vending machine number In order that the audits can easily and unambiguously be assigned to a certain vending machine we recommend to store a vending machine number in the coin changer Configuring a vending machine number reinitialises the coin A N changer and all audit data since the last initialisation will be deleted For reading out printing the c audit data please refer to the separate service manual if necessary If you use a mobile data retrieval unit MDE to audit the coin changer data the vending machine number cannot be changed CiD National Rejectors Inc GmbH Buxtehude 61 Crane Co Company AUDIT c Configuration To set the vending machine number Quick approach Main menu gt E Settings gt Audit module gt Machine number Press key How often Effect 1 1x You enter the main menu 2 1 You enter the SETTING menu You want to enter submenu Apr 3 until Audit module earen You enter the submenu The required 4 1x menu item has already been selected 5 1x Now you can set the MACHINE NUMBER 6 D ei until required digit You highlight the digit to be changed 7 until required value This value is to be set 8 Please repeat steps 6 and 7 to set the other nine digits of the machine number if necessa D D g ry 9 1x You lock the set number in memory You return to main menu operating 10 1X2 x DE 62 National
53. payout units are empty or no appropriate tube hopper coin recycler banknote programmed that credit can either be reset or saved for the next vending operation or customer To reset store the credit which cannot be paid out Quick approach Main menu gt E Settings gt Operating modes gt Residual credit Press key How often Effect 1 bk You enter the main menu You enter the Setting menu The 2 1 x required menu item has already been selected 3 el 1x You enter submenu OPERATING MODES You want to specify how to manage the 4 Until Residual eredit Ee 5 dE Now you can set the function You want the residual credit which 6 Ad ed until setting desired cannot be paid out to be DELETED stored 7 e 1x You lock the setting in memory You return to main menu operating 8 1 x 2 X EE CiD National Rejectors Inc GmbH Buxtehude 29 Crane Co Company 30 CASH ACCEPTANCE c Configuration Cash acceptance This chapter describes how to adapt the acceptance of coins and banknotes to the machine environment Limiting acceptance of coins and banknotes only c BDV Executive Limiting acceptance of tube coins filling level limitation Inhibiting coins Inhibiting high value coins if there is not enough change only c BDV Executive Optimising acceptance of genuine coins rejection of fraud coins defining acceptance tolerances Selecting coin group Aor B Preventing coins from geting stuck in the tubes security stock
54. pper payout and empty signal Recycler settings Setting up communication with recycler Inhibiting high value banknotes depending on change stock only c MDB Paying out all banknotes compensating the machine s security stock only c MDB Bill validator settings only c BDV Executive Setting up communication with MDB bill validator Inhibiting releasing banknote acceptance depending on change stock or card payments Card reader settings only c BDV Executive Setting up communication with MDB BDV card reader Activating second price list for card transactions Limiting debit card recharging only for BDV MDB card readers Reinitialising card reader after each transaction Setting up communication with external audit unit only c BDV Executive 9 Audit option Setting vending machine number Setting date and time Specifying data to be printed Setting output device Selecting printing format Selecting type of output device Activating maximum IrDA readout speed only c with IrDA interface on coin validator Grane Co Company 46 46 47 48 49 50 50 52 54 54 55 56 56 57 58 59 60 61 61 63 64 65 65 66 67 TABLE OF CONTENTS 10 Basic settings 11 12 Changing smallest coin value base value Configuring alternative coin value for second currency or as token value Changing currency calling code only c MDB Changing MDB level only c MDB Selecting mains operation or ba
55. r hopper coins if necessary You return to main menu operating mode C The hopper connectors not in use retain coin value 00 00 Crane Co Company 47 PERIPHERAL c Configuration Setting up communication with hopper s To activate the communication between coin changer and hopper s Quick approach Main menu zs Ke Settings Beriobheral z Hopper Communication with hopper Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu 3 until Peripheral You want to enter submenu PERIPHERAL 4 1x You enter the submenu 5 until Hopper You want to enter submenu HOPPER You enter the submenu The required 6 L menu item has already been selected Now you can set up the communication 7 S with the hopper s You want the communication to be 8 elle until setting desired An EE 9 1x You lock the setting in memory You return to main menu operating 10 1 x 2 x Ee 48 National Rejectors Inc GmbH Buxtehude LU c Configuration PERIPHERAL Specifying active levels of the hopper payout and empty signal In order that the coin changer is able to evaluate the signals coming from the hopper s when a hopper pays out a coin or is empty and can no longer pay out coins only with optional empty detection you must set the signals active levels low high Make sure that all hoppers connected use the same active level for the coin signal or the empty signal cp separate manuals for the NRI hopper curren
56. rate printer interface 1X 1x until setting desired 1x 1 x 2 x The language of the audit receipts has been selected with the dialogue language cp section Selecting menu language in Chap 3 Settings gt Audit module gt Configurate printer interface gt Time Effect You enter the main menu You enter the SETTING menu You want to enter submenu Aupt MODULE You enter the submenu You want to enter submenu CONFIGURATE PRINTER INTERFACE You enter the submenu The menu item for the first setting has already been selected Now you can set whether audit receipts are to be printed with or without date amp time You want the date time to be printed not to be printed You lock the setting in memory Press Eley then Ti and repeat stepts 7 to 9 for settings Product specific data Sales data You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration AUDIT Setting output device Please set once with which printer data acquisition device you want to output audit receipts with or without start button and which format is going to be used EX The language of the audit receipts has been selected with the dialogue language cp section Selecting menu language in Chap 3 Presettings Selecting printing format Two different formats can be used to print audit data Extra broad printout 24 characters line audit data can be separated in since ini
57. redit which cannot be paid out Price holding in the coin changer Usually the prices for the Executive protocol are set in the vending machine so that the coin changer does not know which product has been selected and sold RH In order to be able to hold the prices in the coin changer and include the single product specific turnovers in the audit in this section you will learn how to e set prices in the coin changer and e activate price holding in the coin changer Beyond that the coin changer may display the price of the product selected CiD National Rejectors Inc GmbH Buxtehude 23 Crane Co Company PRICES AND VENDING MODES ONLY c BDV ExEcuTIve Setting prices You can set up to 100 prices Quick approach 24 BM 1p menu gt E Press key MO ON BDO OO fF W Ne bech bech be N ka O Settings gt Selling prices alle EE PE How often 1x 1x until Selling prices 1x until price desired des until required digit until required value c Configuration Effect You enter the main menu You enter the SETTING menu You want to enter submenu SELLING PRICES You enter the submenu You want to set this price Now you can set this price You highlight the digit of the price to be set This value is to be set Please repeat steps 7 and 8 to set the other digits of the price if necessary 1X 1 x 2 x You lock the set price in memory Please repeat steps 5 to 10 to
58. scans the tube filling level Configuring security stock for each tube To configure the security stock 1 9 coins Quick approach Main menu gt E Settings gt Coin settings gt Security stock Press key How often Effect 1 1x You enter the main menu 2 1 x You enter the SETTING menu You want to enter submenu Coin 3 until Coin settings SE A 1x You enter the submenu Yi tt t b S 5 TEE E Wee o enter submenu SECURITY 6 ex You enter the submenu You want to set a security stock for this 7 until tube desired tube Now you can set a security stock for 8 E this tube 9 D e until required digit You highlight the digit to be set 10 elle until required value This value is to be set 11 Please repeat steps 9 and 10 to set the other digit of the security stock if necessary You lock the set security stock in 12 tes memory 13 Please repeat steps 7 to 12 to the security stocks of the other tubes if necessary You return to main menu operating 14 1 x 2 x moie 38 National Rejectors Inc GmbH Buxtehude LU c Configuration CASH ACCEPTANCE Transmitting tube filling level incl security stock to VMC only c MDB The coin changer is able to transmit the filling level of the tubes inclusive of the security stock configured to the vending machine control system To define the data to be transferred Quick approach Main menu gt E Settings gt Operating modes gt Security stock to VMC Press key How often
59. start button exists Main menu gt E Settings gt Audit module gt Configurate printer interface gt Start O DOAN BD AO F amp F W Nre bech m k OH Press key WS we WS BG TE 0 How often 1x 1x until Audit module 1x until Configurate printer interface 1 x until Start button on printer TX until setting desired 1x 1 x 2 x Effect You enter the main menu You enter the SETTING menu You want to enter submenu Aupt MODULE You enter the submenu You want to enter submenu CONFIGURATE PRINTER INTERFACE You enter the submenu You want to set the output device type Now you can select the device type You want to output audit data using a device with without start button You lock the selected type of output device in memory You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration AUDIT Activating maximum IrDA readout speed only c with IrDA interface on coin validator If the changer s coin validator is equipped with an IrDA interface and this interface is used to readout audit data you can set a maximum readout speed of 19 200 Bd in the coin changer To select the maximum IrDA readout speed Main menu gt E Settings gt Audit module gt Configurate printer interface gt IrDA high Quick approach speed Press key 1 2 3 4 5 6 E 7 ES 8 E 9 10 11 Crane Co Company How often
60. steps 9 and 10 to set the other two digits of the filling level limitation if necessary You lock the set filling level limitation in 12 E memory 13 Please repeat steps 7 to 12 to set the filling level limitations of the other tubes if necessary A 32 1x 2 x You return to main menu operating mode National Rejectors Inc GmbH Buxtehude LU c Configuration Inhibiting coins CASH ACCEPTANCE If you want certain coins to be no longer accepted for payment at the machine you may inhibit these coins temporarily EX The coin changer stores the coins 1 16 in ascending coin value order i e coin 01 is always the lowest value and coin 16 always the highest value coin programmed To inhibit release a certain coin Quick approach Main menu gt BE Settings gt Inhibit mask gt Inhibit mask M AN BO GO fF WN r Kuch O Crane Co Company Press key alle alle How often 1 x 1x until Inhibit mask 1x 1x until coin desired 1x until setting desired 1x 1 x 2 x Effect You enter the main menu You enter the SETTING menu You want to enter submenu INHIBIT MASK You enter the submenu The required menu item has already been selected You want to inhibit release a coin You want to inhibit release this coin Now you can inhibit release this coin You want this coin to be inhibited released You lock the setting in memory You return to main menu operating mode
61. the other prices if necessary You return to main menu operating mode You may divide the 100 prices into 2 x 50 prices for card and cash payment The first price list prices 1 50 is valid for transactions without any card inserted cash payment and the second price list prices 51 100 for transactions with a card inserted see section Activating second price list for card transactions in Chap 8 Peripheral National Rejectors Inc GmbH Buxtehude LU c Configuration PRICES AND VENDING MODES ONLY c BDV ExECUTIVE Activating coin changer price holding Ifyou wantthe coin changer to hold the prices and include the product specific sales data in the audit you must activate the price holding function To activate deactivate the price holding function Quick approach Main menu gt E Settings gt Operating modes gt Selling mode gt Price Holding gt Price Holding Crane Co Company Press key How often Effect 1 1x You enter the main menu You enter the Gre menu The 2 1x required menu item has already been selected 3 1x You enter submenu OPERATING MODES You want to enter submenu SELLING 4 until Selling mode MODE 5 1 x You enter the submenu You want to enter submenu PRICE 6 until Price Holding EE You enter the submenu pc HOLDING 7 TX The required menu item has already been selected Now you can activate deactivate the 8 1x Price Horning function You want to activate deactivate t
62. tialisation and since last printout and printed out side by side Unsorted printout 12 characters line To select printing format Quick approach Main menu gt E Settings gt Audit module gt Configurate printer interface gt Printer format Press key How often Effect 1 1x You enter the main menu 2 1x You enter the SETTING menu You want to enter submenu AupIt 3 until Audit module ees A 1x You enter the submenu 5 until Configurate printer You want to enter submenu interface CONFIGURATE PRINTER INTERFACE 6 1x You enter the submenu 7 until Printer format You want to set the PRINTER FORMAT 8 1x Now you can set the format You want the audit receipts to have a 9 DE until setting desired broad format 24 characters line or normal format 10 1x You lock the selected format in memory 11 IW You return to main menu operating Crane Co Company mode 65 AUDIT Selecting type of output device Quick approach Dutton of printer 66 c Configuration The coin changer must know whether the printer or mobile data acquisition device MDE has a start button or not so that the output line of printers readout devices without start button they start to output data as soon as they are connected will be monitored and the data output be stopped after all data has been transmitted EX To select the type of output device Set the NRI printer G 55 0510 to start button not exists and the NRI USB Audit Stick to
63. ttery operation only c MDB Configuring wake up time only c MDB Providing coin changer configuration with write protection for BDV machines only c BDV Batch configuration Configuring coin changer master Storing desired configuration in HENRI Transferring desired configuration to coin changers Adapting individual settings Index c Configuration 68 68 70 71 72 73 74 T5 76 76 T T 78 79 National Rejectors Inc GmbH Buxtehude LU c Configuration ABOUT THIS MANUAL 1 About this manual This manual describes how to set the c concerning e Language and display Presettings e Coin cassette filling and emptying e Prices and vending modes Cash acceptance Change payout Peripherals Audit This manual does not describe the whole functional range ofthe coin changer currenza c or HENRI setting module In order to be able to use the whole functional range of the devices safely as well as to configure all possible functions all manuals and short reference guides for the NRI changer currenza c and HENRI setting module must be read carefully PDF download at www nri24 com gt Text conventions To make it easier for you to navigate within these instructions and to operate the devices the following accentuations were made in the text Safety instructions which you must observe in order to protect operators and equipment Notes which you must observe in order to protectthe environment
64. turn to main menu operating 11 1 x 2 x mae CiD National Rejectors Inc GmbH Buxtehude on Grane Co Company CASH ACCEPTANCE c Configuration Limiting acceptance of tube coins filling level limitation The changer can be configured so that each change tube accepts no more than a specific number of coins When this number of coins is reached in a tube all further coins for this tube are then directed into the cash box temporarily Only when coins have been paid out of this tube coins are again sorted into the tube EX To configure the filling level limitation If this function is not used setting 000 the upper filling level sensor full sensor of the tubes determines irrespective of the number of coins from when the coins will be sorted into the cash box and no longer into the tubes Quick approach Main menu gt EF Settings Coin settings gt z _Eilling level Limitation Press key How often Effect 1 1x You enter the main menu 2 dE You enter the SETTING menu Ye tt t b C 3 until Coan SScLings ae Gadgeten A 1x You enter the submenu until Filling level You want to enter submenu FILLING 5 limitation LEVEL LIMITATION 6 1X You enter the submenu You want to set a filling level limitation 7 Ad e until tube desired Ebert Now you can set a limitation for this 8 17 tube 9 D IC until required digit You highlight the digit to be set 10 elle until required value This value is to be set 11 Please repeat
65. uxtehude 13 Crane Co Company BASIC SETTINGS c Configuration 3 Reinsert coin cassette Insert cassette in upper and lower housing guides Fig 4 B Push cassette into the housing Press cassette down and let it engage in the upper and lower housing guides audible click Fig 4 C 4 Switch the power off and then on again The desired operating mode is activated Configuring wake up time only c MDB For MDB coin changers running in battery mode and with external wake up line a time can be set specifying how long the changer will continue to remain switched on since the last time the vending machine addressed the changer wake up time After the wake up time has elapsed the changer switches off automatically The wake up time is set in seconds Settings under 1 and over 20 will be ignored In this case the coin changer will consider the default setting of 4 seconds To configure the wake up time Quick approach Main menu z bz Settings z Other settings gt Make up Lime Press key How often Effect 1 1x You enter the main menu 2 ES You enter the SETTING menu 3 unt Geer settings Kee to enter submenu OTHER 4 Vx You enter the submenu 5 until Wake up time You want to change the Wake up TIME 6 Tx Now you can change the time 7 Ee until required digit You highlight the digit to be changed 8 Ad e until required value This value is to be set 9 Please repeat steps 7 and 8 to set the other digit of the wak
66. yboard disable 22 Keys in the text 7 L Language 11 Vending machine control system 71 Level MDB 72 81 INDEX Machine Interfaces c2 9 Number 61 Mains operation select 73 Manage prices price holding 25 Manual Additional 8 Conventions 7 Markings in the text 7 MDB Card system 56 Level 72 Menu ltems in the text 7 Language 11 Texts 7 Message display in operating mode 13 Minimum number tube coins 38 Money changer 27 Motor only one active 45 Multiplier cv See Smallest coin value Multi vend 28 N New payout combination 40 Note Acceptance See Banknote acceptance Recycler See Recycler Validator See Bill validator Notes 7 O Only tube coin in filling mode 20 orange c2 9 Output device audit unit 65 66 82 c Configuration E Payout Combination 40 Empty signal hopper 49 Single motor operation 45 Peripheral devices 46 Pictograms in the text 7 Presettings 11 Price holding 25 Prices Display 26 Extra for card payment 57 Manage 23 25 Set 24 Printer audit module 65 Printing Data audit module 64 Format audit module 65 Program tube counters autom 17 R Readout speed audit data 67 Recycler 50 Inhibit high value banknotes 52 Pay out all banknotes 53 Set up communication 50 Remaining credit Limit 42 Reset 29 Store 29 Replenishment Display 21 Transmit to machine 21 Residual credit 29 RJ 45 plug 10 National Rejectors Inc GmbH Buxtehude LU c Configuration
67. za h and hopper interface To specify the active levels Quick approach Main menu gt E Settings gt Peripheral gt Hopper gt Coin signal empty signal of hopper Press key How often Effect 1 1x You enter the main menu 2 dE You enter the SETTING menu 3 until Peripheral You want to enter submenu PERIPHERAL 4 1x You enter the submenu 5 until Hopper You want to enter submenu HOPPER 6 IX You enter the submenu l You want to specify the active level of 7 EE ae ee the coin payout signals coming from PP the hopper 8 1 x Now you can specify the active level The signals are supposed to be Heu until setting desired ACTIVE 7 LOW ACTIVE M a al 10 lee You lock the setting in memory 11 Press A key and repeat steps 8 to 10 to specify the empty signal coming from the hopper only for hoppers with empty detection You return to main menu operating 12 SE mode CiD National Rejectors Inc GmbH Buxtehude 49 Crane Co Company PERIPHERAL Recycler settings Setting up communication with recycler c Configuration If you want the vending machine to pay out banknotes as change you may use the recycler interface to connect a recycler banknote payout unit to the coin changer from which the vending machine can pay out banknotes instead of coins Please consider the following coin changer settings for communication between both devices e Communication set up e No acceptance of high value banknotes if t