Home
M3-Service manual
Contents
1. 2 44 1 43 Pin Name Dir Description Pin Name Dir Description 1 RESET __ Reset 23 DIOW Write Strobe 2 GND Ground 24 GND Ground 3 DD7 Data 7 25 DIOR p Read Strobe 4 DD8 Data 8 26 GND Ground 5 DD6 PI Data 6 27 NC 6 DD9 Data 9 28 SPSYNC CSEL Spindle Sync Cable Select 7 DD5 Data 5 29 NC DMA Acknowledge 8 DD10 Data 10 30 GND Ground 9 DD4 Data 4 31 NC Interrupt Request 10 0011 Data 11 32 NC 11 DD3 Data 3 33 DA1 Address 1 12 DD12 ep Data 12 34 NC Passed Diagnostics 1 DD2 exp Data 2 35 DAO Address 0 14 DD13 Data 13 36 DA2 Address 2 15 DD1 ep Data 1 37 IDE CSO 16 DD14 Data 14 38 IDE_CS1 17 DDO Data 0 39 ACTIVE Led driver 18 DD15 Data 15 40 GND Ground 19 GND Ground 41 5V VCC 20 NC 42 5V VCC 21 NC 43 GND Ground 22 GND Ground 44 GND Ground 3 4 2 8 Port of TFT CON8 06000 o 1 33 28 Pin 11 13 15 17 19 21 23 25 27 29 31 33 Definition TFT Vsync Field synchronization TFT Hsync Line synchronization TFT RO Red Data lowest bit TFT R2 Red Data signal signal TFT R4 Red Data signal the GNDTFT
2. Work Procedure Flow Chart of Front Panel Installation Install transparence Board and button Turnover warehouse Install indicator board Standby application Install key board Disqualification return 39 MMED6000DP M3 Operation instruction of front panel installation Operation step 1 Install key board 1 the panel on the desk install the rubber key in the position where it should be then put the key press board on the rubber key tighten it with PA1 7x6 plug screws of self threading as picture 1 Rubber key s Installation position Put rubber 1 key away b sketch map of rubber key s installation position a part panel sketch map Four PA1 7x6 pl ug screws of self threadi ng i N Key press board p Picture 1 sketch map of rubber key complete assemblely bills of raw and processed material SN Material code Name description quantity 1 131548337002A M3 front rind 1 2 131548337002 M3 rubber key 5 3 131510811010A M3 key press board 1 4 122360PA2305A plug screws PA1 7x6 4 self threading Bills of use tool SN name Specification type parameter quantity Small 1 1 cross screwdriver 2 protective gloves MMED6000DP M3 Operation instruction of front panel installation
3. 55 MMED6000DP M3 Operation instruction of core Operation step 1 Install pump and valve part 3 Uncover the protection sheet of the upper layer of the gelatin sponge paste the valve pack it with 2x100 nylon strapping tape 4 according to the left diagram cut the silicone tube Plug them as the following position as picture 9 Length 27 strapping tape Two director connector pasen Length 100 Length 80 E NEA To the sensor of the function board Picture 9 pump and valve part assemble drawing bills of raw and processed material SN Material code Name description quantity 1 13121000D255A silicone tube 2 5 5 100 1 2 silicone tube 2 5 5 16 1 3 silicone tube 2 5 5 27 2 4 silicone tube 2 5x5x25 1 5 silicone tube 2 5 5 20 1 6 silicone tube 2 5 5 18 1 7 silicone tube 2 5 5 80 1 bills of use tool SN name Specification type parame quanti ter ty 1 stainless steel 450mm 1 ruler 2 scissors 1 5 6 MMED6000DP M3 Operation instruction of core Operation step 2 Install pump and valve part Cut the film to the following figure according to the cladding panel figure e o 5 D 5 D E B 1900 390 cladding panel film2 Picture 10 cladding pane
4. Bills of raw and processed material Operation step 3 Install speaker SN Material code Name description 1 Put speaker in the back shell simultaneity put Speaker built in fitting in E the speaker flat alignment the hole site of fitting and back panel tighten 1 11B11D40805WA speaker welded line 40 80 0 5W 1 them with PA2 9x6 5 tapping screw Then tie the lead of the speaker gt 320086321002 Speaker built in fitting 1 avoid of hurting the line leather 2 Install printer cover and battery cover to the left side of the back panel 3 600 tapping Screw PA2 9x6 5 2 respectively cover to slot 4 131538080001A M3 printer cover 1 quantit y 3 After finishing the steps above please check it according to the 5 131538080002A M3 battery cover 1 request of every working procedure there mustn t be missing bolt and Bills of use tool module put the quality products to thee storage racks waiting for the next TE working procedure SN Name Specification type parameter tity Two PA2 9 X6 5 screws 1 cross screwdriver 1 2 3 picture3 finishing assemble show 76 4 3 3 2 Assembling Drawings of Back Panel 020 91 FSO Picture 9 4 3 4 Unit Assembling 4 3 4 1 Catalogue of task instruction Product Name Multi parameter monitor Product Model MMED6000DP M3 Worki
5. SN Material code Name description quantity Assembling bolt with 1 1223100M3060A spring shim M3x8 2 TFT module 1 3 122360PT3515A tapping screw PT3 5x15 4 1223100M3080A Assemble bolt M3x8 4 bills of use tool pa SN name Specification type c quantity ter 1 Electromotion 4 screwdriver anti static wrist 2 1 strap 3 Installation hole site 84 MMED6000DP M3 Operation instruction of the unit Operation step 4 Install panel module 1 plug the cable of key board in the panel electrify to test if the function is normal install the supporting plate of the core to the core of the main body stick one layer gelatin sponge between core and supporting plate tighten it with M3x8 assembling bolt to the bottom of the shell bills of raw and processed material 2 plug the plug of the key board to the relevant socket button the panel to the front of the unit tighten it with M3 5x15 bolt which are installed from back of the unit SN Material code Name ine a quantity 1223100M3060 Assembling bolt with A spring shim de 2 TFT module 1 3 122360PT3515A tapping screw ee 2 4 1223100M3080A assembling bolt M3x8 4 5 bills of use tool SN name Specification type parameter quantity Electromotion 1 screwdriver anti static wrist 2 1 strap 85 MMED6000DP M3 Operation instruction of the unit powe
6. T i e e s e o s Z amp a z a 5 the mek forth when Instal ihe fan the offtrack pisce to the pump note the direction when Install the module whioh i for switch port e the double face tape to make the binding m on the surface of T Picture 3 6 7 1 eo pee n _ _ _ ee i3 jure eoo ssx 1 71 2 CS2 900 020 L 1 1 Picture 5 68 T i Picture 6 LE i ld the alin pact chroot batery and batery Biles haihin CSB 048 1010 i EIS 2 o e 5 5 1 1 T8 Picture 7 6 9 Picture 8 4 3 3 Back Panel Installation 4 3 3 1 Catalogue of task instruction Product Name Multi parameter monitor Product Model MMED6000DP M3 Working procedure Operation name version Changing contents installation of back cover 1 Install knob 2 Install side panel 501 3 Install speaker A01 4 A01 Self test 71 Work Procedure Flow Chart Of back cover installation Y C 7 Standby application Inatall speaker Turnover arehouse Disqualification return 2 MMED6000DP M3 Operation instruction of back panel
7. 6 Assemble main body and pump valve part 3 complete assembling the battery contactor panel weld the polarity pinout as picture 19 then install the module to the main body welding spot direction Battery contactor shrapnel Install M3x10 assembling bo Black lead 7A plain cushion M3 nut Assemble completion drawin gt d Picture 19 battery contactor panel assemble drawing bills of raw and rocessed material SN Material code Name poa ia quantity 1 1131530781002A battery contactor panel 1 2 322768382005A battery contactor panel 1 q 12273048101 battery contactor 2 shrapnel 4 1223100M3080A assembling bolt M3x10 5 1223100M3050A assembling bolt M3x6 3 bills of use tool quan SN name Specification type parameter tity 1 cross screwdriver 1 2 electric iron 1 3 scissor 1 66 4 3 2 2 Assemble Drawings of core E T pa 0 0 i 8610001 rer reme m cmm 1 maaa p pe CA cruciform siot screw N2 5 5 cruciform slot screw Vix 6 004 bsttery caos 001 008 001 3 TET CSB 044 002 corner piece fhe CSN507boerd S3 543 001 CS8 048 1012 ledger plate for printer 037 101 i E 2g 28 8 o amp Doo e la
8. Operation step bills of raw and processed material 1 Install key board 2 put key board on the key press board after aiming at the fix quanti hole tighten it with PA1 7x6 plug screws of self threading and then tighten the SN Material code Name description y hotoelectricity coder with nut on the front panel E picture2 i 1 260022320130B Key board 1 2 122360PA2306A plug screw PA1 7x6 6 Six PA1 7 X 6 screws 3 4 5 bills of use tool SN Name Specification type parameter c Picture 2 sketch map of key board s installation 1 Cross screwdriver 1 2 protective gloves MMED6000DP M3 Operation instruction of front panel installation Operation step bills of raw and processed material 1 Install alarm indicator board SN Material code Name description quantity 1 pull the alarm indicator cable on the via of the board weld the lead on the 1 600029010134 Alarm indicator board 1 jointing position As picture welding pin1 to the GREEN bonding pad pin 2 to the RED bonding pad pin 3 to the GND bonding pad After welding put little hot melt 2 3100066441115A Alarm indicator cable adhesive on the indicator welding spot 1 3 soldering tin 4 hot melt adhesive bills of use tool SN Name Specification type parameter quantity 1 electric iron 220V 25 30W 1 2 3 4 installation hole RED GREEN
9. welding spot Picture 3 Definition picture of alarm indicator cable welding pin MMED6000DP M3 Operation instruction of panel installation Operation step 2 Install alarm indicator board 2 put the alarm indicator on the fix position tighten it with PA1 7x6 plug screws of self threading as picture 3 3 install the rotate knob top light s lampshade and transparent board put little hot melt adhesive on the left and right of top light s lampshade complete the installation of the panel plug Screws of Part panel self threading Alarm indicator board Alarm indicator MM Put little adhesive E 3 on the side of the lampshade Picture 4 sketch map of alarm indicator board s installation completion bills of raw and processed material SN Material code Name description e 1 131536341001A M3 top light s lampshade 1 122360PA2306 Plug Screws of PA1 7x6 2 2 A self threading 3 hot melt adhesive bills of use tool SN Name Specification type parameter quantity 1 Cross screwdriver 1 2 protective gloves 1 3 hot melt gun 1 IMED6000DP M3 Operation instruction of panel installation peration step bills of raw and processed material 3 install transparent board and rotate knob SN Material code Name description quantity take off the protective film which is on the tran
10. MMED6000DP monitor and sensor surface can be cleaned with hospital grade ethanol and dried in air or with soft and clean cloth Choice Co has no responsibility for the effectiveness of controlling infectious disease using these chemical agents Please contact infectious disease experts in your hospital for details 9 3 Sterilization To avoid extended damage to the equipment sterilization is only recommended when stipulated as necessary in the Hospital Maintenance Schedule Sterilization facilities should be cleaned first Recommended sterilization material Ethylate and Acetaldehyde CAUTION 1 Follow the manufacturer s instruction to dilute the solution or adopt the lowest possible density 2 Do not let liquid enter the monitor 3 No part of this monitor can be subjected to immersion in liquid 4 Do not pour liquid onto the monitor during sterilization 5 Use a moistened cloth to wipe off any agent remained on the monitor 6 To avoid extended damage to the equipment disinfecting is only recommended when stipulated as necessary in the Hospital Maintenance Schedule Disinfecting facilities should be cleaned first 7 Appropriate disinfecting materials for ECG lead SpO2 sensor blood pressure cuff TEMP probe IBP sensor are introduced Operator s Manual respectively 8 Do not use EtO gas or formaldehyde to disinfect the monitor 9 4 Precondition and cleaning NOTE Before cleaning the monitor or the sensor make su
11. Pin Cor N 0 Oy A O Po Name V 15V VBatt GND Bett ST Open Close Vout 5V VIS 5V Vin Definitions Power output of Charge indicate light Examination output of battery power Ground Control of charge indication light Power switch input 5V output 5V input 15V DC power input 3 2 2 2 P2 15VDC Input Port Pin Name Definition 1 GND Power Ground Input 2 GND PowerGroundlnput Power 15 4 Power input 15V 3 2 2 3 P3 Fan and speaker control port Pin Name Definition 1 SPKCTLA Speaker volume control input 2 SPKCTLB Speaker volume control input 3 SPKCTLC Speaker volume control input 4 FAN CIL Fancontrolinpt gt gt 3 2 2 4 P4 Chargeable Battery Port 2 1 Pin Name Definition 1 GND Ground 2 VBatt Battery input 3 2 2 5 P5 Speaker Port 12 Pin Name Definition 1 GND Ground 2 SPK CTL Speaker control signal output 3 2 2 6 P6 Audio Frequency Signal Input Port 12 Pin Name Definition 1 GND Ground 2 SPK IN Audio frequency signal input 3 2 2 7 P7 Fan port 12 Pin Name Definition 1 FAN OUT Control signal output 2 Vout 12V Fan power output 3 2 2 8 P8 Printer Power Port Pin Name Definition 1 Vout 5V 5Voutput 2 GND Ground 3 Vout 12V Power output 3 2 2 9 P9 801 Function Panel Power Port Pin Name Definition 1 GND Ground 2 GND Ground 3 Vout 6V Power output 4 Vout 6V Power output
12. Power supply in in place Picture 17 main body and power supply assemble process drawing bills of raw and processed material SN Material code Name description quantity 1 Main body module 2 Power supply part module 1223100M3050A assembling bolt M3x6 4 bills of use tool SN name Specification type parameter quanti cross screwdriver 64 MMED6000DP M3 Operation instruction of core Operation step 6 Assemble main body and pump valve part 1 Cut the film according to the main body figure then stick it to the flat roof of the metal sheet 2 Put pump valve part module in the installation poison where the top main body metal sheet is put the lead in the frame of the main body tighten it with assembling bolt as picture 18 1440 film of main body metal sheet Install Pump module In the main bo picture18 main body metal sheet and pump valve part assemble drawing Main body module bills of raw and processed material SN Material code Name description quantity 1 320008610005A film of main body 1 metal sheet 2 1223100M3050A assembling bolt M3x6 4 bills of use tool SN name Specification type parameter 1 cross screwdriver 1 2 scissor 1 3 stainless steel 1 ruler 65 MMED6000DP M3 Operation instruction of core Operation step
13. 100bpm 1 2100bpm 2 Heart rate high and low limits alarm delay 12s Detected and displayed 0 8mV to 0 8mV 0 05mV 0 to 100 80 100 2digits 70 80 3digits 0 69 Unspecified Wavelength Radiant Power RED 660x2nm 1 8mW IR 905x10nm 2 0mW Spo2 high and low limits alarm delay 7s bs 196 30 to 300bpm 1bpm 1bpm Pulse rate high and low limits alarm delay lt 7s Oscillometric method with inflatable cuff Determines systolic diastolic and mean arterial pressures Adult Pediatric and Neonate 3 15 seconds depending on cuff size Cuff Inflation Pressure Measurement Modes Measurement Interval Time Measurement Range Systolic Diastolic Mean Arterial Pressure Resolution Accuracy Determination Time Overpressure Valve Adult Neonate Overtime Protection Adult Neonate Alarm delay RR Technique Range Resolution Alarm delay TEMP Technique Channel Scales Probes Range Revolution Accuracy Alarm delay Auto 180mmHg Manual 9 3kPa 70 mmHg 13 3kPa 100 mmHg 16 0kPa 120 mmHg 18 6kPa 140 mmHg 20 0kPa 150 mmHg 21 3kPa 160 mmHg 24 0kPa 180 mmHg Manual Immediate upon operator command AUTO Determinations automatically made with selectable intervals STAT Determinations continues in 5 minutes 1 240min Step 1min 1 10min 30min 90 240min 5min 10 30min 10min 30 90min 30 255mmHg 10 220mmHg 20 235mmHg 1mmHg Cuff Pressure Range 0 to 275mmHg Pressure S
14. YES YES Reconnect the Change connectors AC DC power supply 8 9 Change Ten SEN AC DC POWER SUPPLY output 15V Change the power board you ie the voice NO Is Ch of mainboard power on supply voltage ange self checking OK the power board YES Change the LCD displayer Change the mainboard 9 0 BLOOD PRESSURE Is connector Reconnect cuff hose connected connectors properly NO Does PUMP work Does cuff inflate Change the CSN801 1 Is there air leak board NO Is pressure inflated to Change the CSN801 pre set valve Is there air leak Is deflation speed OK Are CUFF and Change CUFF and AIR AIR HOSE OK HOSE Change the CSN801 board Change the CSN801 Is 5V supplied to board the valves YES l Change CUFF and AIR HOSE 9 2 Turn power OFF and ON again NO NO Change the CSN801 board Does PUMP work Is 5V supplied to the pump Change the pump 93 NO ECG MEASUREMENT NO Is there ECG ERROR alarm Change Is 5 supplied voltage is OK Power board YES Change CSN801 board Change ECG cable and Lead wire Are ECG cable and lead wires OK Are electrodes Replace the electrodes refer to operation manual placed OK Change CSN801 board 94 NO TEMPERATURE READING NO Is temp
15. 2 76 3 106 CHAPTER 7 ADJUSTMENT PROCEDURE NOTE The MMED6000DP Monitor contains a great number of Static Sensitive circuits All service procedures must be done by grounded personnel 7 1 ECG adjustment ECG gain is fixed User cannot adjust it If ECG gain dose not meet the standard demand Please contact the service person of Choice Co 7 2 NIBP adjustment 7 2 1 Cuff pressure calibration Perform cuff pressure calibration as follows D Connect a manometer with the NIBP inflating port as Fig 7 1 connector of pressure transdusor Fig 7 1 2 Perform the following to set CAL ON a Rotate and press the knob to enter NIBP menu b Then highlight ALARM to select the submenu C Select for CAL Inflate the cuff manually by pressing the rubber ballonet 4 Inflate the cuff to 200mmHg and observe the NIBP value displayed on the monitor if which equals to the value displayed on the manometer If the error exceeds 3mmHg adjust the VR1 on the CSN801 board shown as Fig 7 2 VR1 d j Lo 47 ss Sz 3 ES abe Mee ited 4 Fig 7 2 1 2 2 Setup of deflection and offset Rotate the knob to call up ALARM submenu of NIBP set the high limit and low limit to maximum For example if you want to adjust systolic set the high limit of systolic to 255 low limit to 220 then press RETURN to return the superior menu next press RETU
16. 3 MONITOR FUNCTION and PRINCIPLE 3 1 Connection Drawings CS6 644 1236 2 CS6 644 1243 power CSN510 o 7 ele gt alo E ul 2192 N ej e JE So oj alo o ui Uu ala battery e mim 3 3 E s 8 56 644 1239 LOLT FES 952 1 xoe semod Aozz Internet interface VGA interface 6hZI PPO 9S9 ED 9 cse 644 1242 CSN801 D 3 rahi pump amp valve Valve board 1 3 pump LCD screen data fable CSN908 CSN718 mainboard printer data canle cse 644 1241 cse 644 1150c 3 to rear panel SP02 56 644 11498 3 to rear panel 1 2 cse 644 1151 to rear panel ECG 14 The concrete connection is described in the following table Number From To Cable and specification 1 Power board P9 801 board P11 CS6 644 1236 2 Power board P11 Main board J3 CS6 644 1243 3 Power board P8 Printer power CS6 644 1251 4 Power board P10 Inverter CS6 644 1235 5 Power board P1 Keyboard P6 CS6 644 1237 6 Keyboard P4 Mainboard J10 CS6 644 1239 7 Power board P3 Keyboard P3 CS6 644 1246 8 Power board P4 Chargeable battery CS6 644 1168 9 Power board P2 Power adapter CS6 644 1240 10 AC DC power 220V power jack CS6 644 1167 11 CSN718 CON2 VGA interface CS6 644 1241 12 CSNB801 board J2 J3 on
17. GO Green Data signal the lowest bit TFT G2 Green Data signal TFT G4 Green Data signal TFT BO Blue lowest bit TFT B2 Blue Data signal TFT B4 Blue Data signal Data signal LCD POWER 5V 3 3V power optional LCD POWER 5V 3 3V power optional LCD POWER 5V 3 3V power optional GND GND GND the is is is Pin 12 14 16 18 20 22 24 26 28 30 32 34 Definition TFT CLK Clock TFT MODE ENAB Data enabled signal TFT R1 Red Data signal TFT RS Red Data signal TFT R5 Red Data signal the highest bit TFT G1 Green Data signal TFT G3 Green Data signal TFT Gb5 Green Data signal the highest bit TFT B1 Blue Data signal TFT B3 Blue Data signal TFT B5 Blue Data signal the highest bit GND GND GND GND GND GND 3 4 2 9 Portof VGA CON2 CON2 1 Pin Name Definition 1 VGA_R Red 2 GND Ground 3 VGA_G Green 4 GND Ground 5 VGA_B Blue 6 NC Open 7 GND Ground 8 LCD_H Line synchronization signal 9 GND Ground 10 LCD_V Field synchronization signal 3 4 2 10 Port of network card CON4 2 10 1 g Pin Name Definition 1 LINK LED LED1 2 LINK LED LED1 3 100M ACT LED LED2 4 100M ACT LED LED2 5 RX Receive Data 6 RX Receive Data 7 TX Transmit Data 8 TX Transmit Data 3 0 9 AGND 10 AGND 3 4 2 11 Parallel Port CON5 CON5 PIN NAME DEFINITION 1 STROBE Strobe 2 DO Data Bit 0 3 D1 Data Bit 1 4 D2 Data Bit 2 5 D3 Data Bit 3 6 D4 D
18. Mainboard s BIOS is damaged rewrite BIOS programme or replace the main board User Limited Enter 1 the expire date is earlier 1 change the setting password than the current date 2 change the setting 2 the runtime is over the 3 replace it usetime 3 the mainboard is bad Boot failure Mainboard is damaged replace Insert disk in unit A 100 5 3 Error Message Message Cause of Error ECG ERROR Cannot communicate with ECG part of CSN801 board LDOFF ECG cable or electrodes are off PLETH ERROR Cannot communicate with SPO2 part of CSN801 board PROBE OFF SPO2 sensor is off 101 CHAPTER 6 CALIBRATION OF MONITOR 6 1 Required testing tools The following tools are required to perform calibration and verification on the MMED6000DP monitor Mercury Manometer Patient Simulator ECG 30 to 300bpm 0 5 2 0 amplitude 1mV square wave at 10Hz Temperature Simulator 25 to 45 C NIBP Simulator 0 to 250 mmHg Respiration testing tool Respiration 30bpm 0 1 to 3 0 Ohm impedance baseline impedance 500 Ohm SPO2 signal Simulator 6 2 Power on the monitor For AC operation confirm that AC Power wire is plugged in the connector on the rear panel and LED Power Indicator is lit Orange For internal battery Operation confirm that the LED Power Indicator is illuminated Green Confirm that the Screen is displayed wit
19. P105 SpO2 Signal Input Port Pin Name Definition 1 Signal Signal pin 2 LED Driving signal 3 LED Driving signal 4 IN Receipt signal input 5 IN Receipt signal input 23 6 GND Ground 3 3 2 7 P200 ECG Signal Input Port Pin Name Definition 1 SHIEID Shield pin 2 RL RL electrode 3 VX VX electrode 4 LL LL electrode 5 RA RA electrode 6 LA LA electrode 3 3 2 8 P252 T1 T2 Signals Input Port F Definition 1 GND Ground 2 VIN 1 AD conversion in reverse input 3 VIN 7 1 AD conversion in phrase input 4 VIN 2 AD conversion in reverse input 5 VIN 2 AD conversion in phrase input 3 4 Connection Drawing of CSN718 Mainbord 3 4 1 lintrduction CSN718 is the special mainboard for 6000DP MS3 The PCB of CSN718 board is as follows 24 ji2 11 j10 J9 IA Ue Ta J5 5 ee DEN W da S ad CONS w Si oes CON5 BR lag aras E nmm mium TTL sesso CONT Soos Cg J Ugg Lg J co Su 6 CON2 3 4 2 Port of system The plug on the board is set for customers to select application functions These plugs are connected respectively to external connecting equipments such as the hardware serial port and so on The following table describes the plugs function respectively PIN Function CON1 IDE DOM port CON2 VGA port CON4 Network port CONS Parallel port 25 CON8 TFT d
20. Pump amp valve board CS6 644 1249 13 CSN801 board P105 Rear panel SpO2 CS6 644 1150C 14 CSN801 board P201 Rear panel T1 T2 CS6 644 1149B 15 CSN801 board P200 Rear panel ECG CS6 644 1151C 16 CSN801 board J1 J1 of Pump amp valve board CS6 644 1248 17 Keyboard P2 Alarm light board CS6 644 1115 18 Keyboard P5 Sensor CS6 644 1245 19 Mainboard CON4 Internet interface CS6 644 1242 20 Power board P7 Fan CS6 644 021B 21 Power board P5 Speaker CS6 644 021E 22 Power board P6 Mainboard J6 CS6 644 1244 23 P10 of CSN801board Mainboard J9 CS6 644 1238 3 2 Power supply unit 3 2 1 Power board CSN510 is special power board for 6000DP M3 The PCB of CSN510 is as follows Pg p2 P4 cnc JE E e pa 3 2 2 Ports of power board The Power board CSN510 provides power supplies to SN718 mainboard CSN801 board CSN717 keyboard charge battery LCD displayer speaker fan and printer and 50 on The port function is described as follows table NUMBER FUCTION P1 P2 P4 P5 P6 P7 P8 P9 P10 P11 Port of Keyboard CSN717 Port of 15VDC input Control port of fan and speaker connect to the keyboard Port of chargeable battery Port of speaker Port of audio frequency input connect to the csn718 main board Port of fan Power Port of printer Power Port of 801 mainboard Power Port of inverter Power Port of csn718 mainboard 3 2 2 1 P1 Port of CSN717
21. assembling bolt 1 322918038015A 220vport sheet metal 1 2 install the earth terminal to the right position then tighten it with6 spring 2 eae re b match FAST shim plain cushion and M6 nut 6006644116 345 260066441253A M3 use AC power cable matchFA53D 1 11X710D06000A earth terminal 06 1 assembling bolt M3x10 4 5 nut plain cushion M3 spring shim bills of use tool para c lan SN name Specification type met p er y Sleeve 1 1 screwdriver Power plug without fuse amp 2 cross screwdriver 1 M3 10 assembling bolt picture13 power plug and earth terminal assemble drawing 6 0 MMED6000DP M3 Operation instruction of core Operation step bills of raw and processed material 3 Power part SN Material code Name description quantity d Su cen tape ren ae ubi side protection sheet to 1 11A51FA53D00A Power supply adapter FA53D 1 Stick it to the back part of the adapter as picture 9 then uncover 2 1816100W10MMA double face tape the top protection sheet of the double face tape stick the film to the adhesive tape 3 320008610003A Adapter film 1 1 4 close the side of the adapter to the port sheet metal adjust the hole sit 4 320008610004A Adapterfilm 2 1 tighten it with M3x6 assembling bolt as picture 9 5 1223100M3050A assembling bolt M3x6 3 5 check self test bills of use tool Specifica
22. check of the monitor including the safety check should be performed only by qualified person once every 6 to 12 month and each time after fix up 9 2 General cleaning 1 MMED6000DP Patient Monitor must be kept dust free 2 It is recommended to regularly cleaning the monitor shell and the screen Use only non caustic detergents such as soap and water NOTE Please pay special attention to the following items to avoid damaging MMED6000DP 1 Avoid using ammonia based or acetone based cleaners such as acetone Most cleaning agents must be diluted before use Follow the manufacturer s directions carefully for dilution 3 Do not use the grinding material such as steel wool etc 4 Do not the cleaning agent enter into the chassis of the system Do not emerge any part of the device into any liquid 5 Do not leave the cleaning agents on any part of the device surface 6 Except for those cleaning agents listed in NOTE part following disinfectants can be used on the instrument Diluted Ammonia Water 111 Diluted Sodium Hyoichlo Bleaching agent NOTE The diluted sodium hyoichlo from 500ppm 1 100 diluted bleaching agent to 5000ppm 1 10 bleaching agents is very effective The concentration of the diluted sodium hyocihlo depends on how many organisms blood mucus on the surface of the chassis to be cleaned Diluted Mindrayhylene Oxide 35 37 Hydrogen Peroxide 3 Alcohol isopropanol NOTE
23. if the function of ECG Lead Off works orderly D Attach the lead to the ECG patient simulator 2 Set the patient Simulator to output a 1 0mV QRS pulse at 60BPM 3 Select ECG Lead I 2 Remove one lead from simulator in turn that pertains to the selected lead until all the leads have been tested In this situation verify that LEADOFF message appears in ECG displaying frame of parameter area in 12S Disconnect the Patient Simulator from the monitor front panel the LEADOFF message appears 6 7 2 ST segment test Perform the following procedure to verify if ST segment program works orderly D Rotate and press the knob to enter ECG menu Rotate knob to select the lead II item Set Patient Simulator to 1mV 60bpm POS at 0 8 setting Verify ST reading of 0 8 0 05 Set Patient Simulator to 1mV 60bpm POS at 0 8 setting Verify ST reading of 0 8 0 05 6 8 Respiration test D Attach the lead to the ECG patient simulator 2 Rotate and press the knob to enter RESP menu Select INDEP for RESPTYPE item in the RESP submenu Set the Respiration Simulator to 0 5 Ohms impedance with baseline impedance of 1000 Ohms 8 Set the Respiration Simulator to 15bpm verify the RESP waveform correct and the number indicate an RESP count of 15bpm Set the Respiration Simulator to 30bpm verify the RESP waveform correct and the number indicate an RESP count of 30bpm Set the
24. light 5 Open Close Power switch input 6 Vout 5V 5V output 7 VIS 5V 5V input 8 Vin 15V DC power input 3 5 2 2 P2 Port of Panel Indication Light Pin Name Definition 1 Signal signal output of indication light Signal signal output of indication light GND Ground 34 3 5 2 3 P3 Fan and speaker control Port Pin Name Definition 1 SPK CTLA Speaker volume control output 2 SPK CTLB Speaker volume control output 3 SPKCTLC Speaker volume control output 4 FAN CTL Fan control output 3 5 2 4 P4 Serial port of CSN718 Board Pin Name Definition 1 GND Ground 2 TXD Serial input 3 RXD Serial input 3 5 2 5 P5 Temperature Sensor Pin Name Definition 1 GND Ground 2 D TEST signaloutput of temperature examination 3 VIS 5V Power input 35 CHAPTER 4 COMPONENT and STRUCTURE 4 1 Component 4 1 1 Main components of monitor 1 Standard No Production Description Standard Quantity 1 Main board CSN718 1 piece 2 Cable of LCD 1 piece 3 CSN801 board 1 piece 4 Power board CSN510 1 piece 5 Power inverter 1 piece 6 Build in power adapter 1 piece 7 Build in battery 1 piece 8 LCD screen 1 piece 9 Deflation valve 2 piece 10 Inflation pump 1 piece 11 Keyboard CSN717 1 piece 12 Speaker 1 piece 13 Fan 1 piece 2 Option No Production Description Standard Quantity 1 IBP module 1 piece 2 Et CO2 module side stream 1 piece 3 Thermal array recorder 1 pie
25. material SN Material code Name E quantity 1 Pump cable 3 2 182A1KPM27C6A Charge valve DC 6V 1 3 182A113A08A1A Flectromagnetic CJ 1 3 A06A 2 valve own line 4 11X1102542P0 PTK plug 2 54 2P XH 2 5 2 heat shrink tube 6 hot melt adhesive bills of use tool SN name Specification type meas 1 electric iron 1 2 calorifier 1 54 MMED6000DP M3 Operation instruction of core Operation step 2 Install pump and valve part 2 Put the pin of valve that is face to the rectangle via of cladding panel to the right position Pack it with 4x150 nylon strapping tape 3 stick it at the installation position with gelatin sponge as picture 8 gelatin sponge via oF Trot cladding panel pump E e Picture 8 pump assemble drawing bills of raw and rocessed material SN Material code Name description c pump and valve 1 which weld module cable 2 13211CV15036A nylon strapping tape 4x150 2 3 13211CV10025A nylon strapping tape 2x100 4 4 133330L20HMJA gelatin sponge wide 20mm 5 322918038013A cladding panel S 1 bills of use tool SN name Specification type parameter quantity 1 long flat nose pliers 1 2 diagonal cutting nippers 1 3 scissors 1
26. of SpO2 Failure Possible cause Solution No SpO2 waveform Sensor is damaged Replace the sensor and confirm the failure SpO2 waveform has strong interference D Patient is moving Environment light is very intensive D Keep the patient quiet Weaken the light intensity in the environment SpO2 value is inaccurate Coloring agent has been injected into patient body Remove the coloring agent before perform measurement SpO2 sensor is hot SpO2 sensor is damaged Replace the SpO2 sensor SpO2 wave displays as infill no SpO2 data CSN801 board has problem Replace the board SpO2 wave displays as zigzag waveform The problem of ground wire Reconnect the ground wire 5 2 6 Display failures Failure Possible cause Solution When powering on the D Backlight board damage D Connect external VGA 9 9 device power supply is in Bad connecting wire of display and confirm the normal operation however display failure screen goes black during 3 Damage of mainboard 2 Repair replace normal operation The battery is connecting wire undercharge Replace main board Charge the battery 5 2 7 Operation recording network linking failure Failure Possible cause Solution Key or rotary encoder is D Keyboard rotary D Replace keyboard or disabled encoder
27. speaker is 5 134538080001A printer cover 1 2 plug the port cable to the printer install the printer to the left side ad 00 3050 screw uis 2 of the back cover pass one side of the connector cable to the via of the main body core then push the printer in place 92 900 020JL hookup 1 tighten them with M3x8 nut to the ledger plate 5 3 plug the other terminal to the corresponding socket according to bills of use tool the hookup synchronously plug the other cable pack the cable in order SN name Specification type id lity Position of _ Electromotion 1 installation screwdriver printer SE 2 anti static wrist 1 strap Close to the position of mut installM3 X 8 nu ziii picture5 printer installation drawing MMED6000DP M3 Operation instruction of the unit Operation step 3 install TFT module Pack the sensor cable which is to the key board according to the drawing take the other lead to the right side of the shell plug the soft cable and correlative lead of TFT Hang TFT module to the stander of main body adjust the installation hole then tighten it with M3x8 assembling bolt as picture 6 sensor main board Cable of key Power board board Picture 6 sensor cable packing drawing Hang place lt lt Picture 7 TFT module assemble drawing bills of raw and processed material
28. 3 2 2 10 P10 Inverter Power Port 12 Pin Name Definition 1 GND Ground 2 Vout 12V Power output 3 2 2 11 P11 CSN718 Main board Power Port Pin Name Definition 1 GND Ground 2 GND Ground 3 Vout 5V Power output 4 Vout 5V Power output 3 3 CSN801 board 3 3 1 General description PCB of 801 Jl J6 J2 Pt PIO 1 n n LI L an 7 uU r 31301 LILILILJ In LUU A Ga L cJ L l L3 i t 3 3 5 J 2 RE D UL 7 Homin P200 P252 P105 3 3 2 801 Ports Functions of 801 ports are described as follows Designator Function J1 Valve port J2 Pump port J6 Valve port P4 Reserved P10 Serial port connecting to CSN718 P11 Power input P105 SpO2 signal input port P200 ECG signal input port P252 T1 2 signals input port 3 3 2 1 J1 Valve port FL 12 Pin Name Definition 1 VDD Power output 2 Signal Control signal output 3 3 2 2 J2 Pump Port 12 Pin Name Definition 1 VIN Power output 2 Signal Control signal output 3 3 2 3 J6 Valve Port 12 Pin Name Definition 1 VDD Power output 2 Signal Control signal output 3 3 2 4 P10 Serial Port Connecting to CSN718 22 Pin Name Definition 1 OTXD Serial output 2 ORXD Serial receipt GND Ground 3 3 2 5 P11 Power Input Port Pin Name Definition 1 VIN Power input 2 VIN Power input 3 GND Ground 4 GND Ground 3 3 2 6
29. 6 Valve pinout plug 2P 2 17 Indicator cable Power board P2 Indicator pin 3P 1 18 M3 sensor cable Power board P5 To the sensor 3P 1 19 network card connector cable Power board Network car 1 CONA connector 20 Fan cable Power board P7 Fan 2P 1 21 Speaker cable Power board P5 speaker 2P 1 22 M3 audio output cable Power board P6 Mainboard J6 2P 1 23 M3 CSNS801 board serial port line 801 board P10 Mainboard 9 3P 1 86 4 3 4 2 Assembling Drawings of Unit 2 8 bes eu oj Bu puo22 amp 19A02 xX2eq Weq1exoos opne MES eu geisul t d Ph 1 L p N be s d A j Ly F s NN OW j laty 3 po E NBX AP NS 1 972 gt v SS P Oe LASS s 27 e n A gt yoq Bujquusse gygy seajd Jesu ul een LI _ Jj Tt eopnou M yOB Sy JO eu oj jeydurep eoeyieju 5 epis eu uj uojysod pod Aasa jsn pe eye 020 G82 ZS Picture10 CS2 900 020 Picture 11 8 8 CHAPTER 5 TROUBLESHOOTING 5 1 Diagram of solutions to various troubles A NO DISPLAY WITH AC MAIN POWER ON NO Is Power Supply Indicator LED lighted Is fuse blown YES NO YES Replace fuse NO NO Are there any 9 Is LCD screen Replace the loose connectors backlight inverter lighted Is fuse blown again _
30. MMED6000DP M3 CSN801 Service Manual Edition MMED6000DP CSN801 Issued date JUNE 2007 COPYRIGHT Company owns all right to this unpublished work and intends to maintain this work as confidential Beijing Choice may also seek to maintain this work as an unpublished copyright This publication is to be used solely for the purpose of reference operation maintenance or repair of Choice equipment No part of this can be disseminated for other purposes In the event of inadvertent or deliberate publication Beijing Choice intends to enforce its right to this work under copyright laws as a published work Those having access to this work may not copy use or disclose the information in this work unless expressly authorized by Beijing Choice to do so All information contained in this publication is believed to be correct Choice shall not be liable for errors contained herein nor for incidental or consequential damages in connection with the furnishing performance or use of this material This publication may refer to information and protected by copyrights or patents and does not convey any license under the patent rights of Beijing Choice nor the rights of others Beijing Choice does not assume any liability arising out of any infringements of patents or other rights of third parties Content of the manual is subject to changes without prior notice CONTENT Chapter 1 Introduction General Description of abbreviation Explanation of s
31. N for SOUND in ECG menu the detailed operation please refer to the Section 9 5 ECG Menu of Operator s Manual You will hear the simulated heart beep 6 5 Test of automatic storage Enter the ECG setup menu Change the lead setup e g select aVF for LEAD Turn off the monitor and power on it after 5 minutes Thelead should be the value you set up just now 6 6 Alarm test 6 6 1 ECG alarm test D Connect the ECG Patient Simulator to the ECG input on the monitor side panel 2 Set the Patient Simulator to output a 1mV QRS pulse at 60bpm set the lead of ECG submenu as 11 Set the heart rate high limit as 58bpm low limit as 30bpm 4 Set the heart rate alarm as on 5 Verify the heart rate visual and auditory alarms the heart rate data should flash and dudu voice should be heard Disconnect the ECG Patient Simulator 6 6 2 NIBP alarm test D Connect the NIBP Patient Simulator to the NIBP input on the monitor side panel Set the Patient Simulator to output Systolic 120 Diastolic 80 Set the systolic high limit as 110 low limit as 60 4 Set the NIBP alarm as on 5 Verify the systolic visual and auditory alarms the systolic data should flash and dudu voice should be heard 6 6 3 SPO2 alarm verification D Connect SPO2 Probe to the SPO2 connector on the monitor side panel Insert the operator s finger into the finger sensor the SPO2 measured value of healthy person sh
32. RN of the 107 superior menu again back the main menu at that time you will find NIBP menu has changed as Fig 7 3 ALARM Fig 7 3 SYSQUTY quotiety of diastolic and systolic value SYSOFFS offset of diastolic and systolic value 7 3 SpO2 adjustment D Rotate the knob to highlight the SPO2 icon in the displaying area pick the SpO2 icon to call up the SpO2 setup menu as Fig 7 4 AU OC Fig 7 4 2 Then press ALARM icon to enter ALARM submenu set the high limit to 100 maximum and low limit to 99 maximum PR ALARMLEVEL PROBEOFFHIGH RETURN Fig 7 5 8 Press RETURN to enter the SpO2 main menu which has changed as Fig 7 6 OFFSET item displays on the screen You can adjust the value in this item For Example if the SpO2 value is lower than standard you can adjust OFFSET value as 3 Figure 4 If the value is higher than standard you can adjust value as 2 JW NEN UT eoN OFFSET SOUND WAVEDRAW RETURN Fig 7 6 108 CHAPTER 8 DISASSEMBLY PROCEDURE 8 1 Battery disassembly Remove AC power wire from monitor rear panel Open the cover of battery and then press baffle The battery can be pushed out automatically Fig 8 1 Fig 8 2 8 2 Monitor disassembly NOTE The disassembly procedures should be performed by qualified person Perform the following procedure to op
33. Respiration Simulator to 60bpm verify the RESP waveform correct and the number indicate an RESP count of 60bpm 6 9 Temperature test 104 Connect a Temperature Simulator to the T1 input on the monitor side panel Verify the following readings 1 30 C 0 1 C 2 35 0 1 C 3 40 0 C 8 Connect a Temperature Simulator to the T1 input on the monitor side panel 4 Verify the following readings 1 30 C 0 1 C 2 35 0 1 3 40 0 6 10 NIBP test D Connect the manual mercury manometer to the NIBP socket 2 Set the CAL ON at the NIBP submenu of the monitor 8 Inflate the cuff pressure manually to 50mmHg according to the reading of the manual mercury manometer then the cuff reading of the monitor should be 50 3mmHg 4 Verify the following points Reading of the manual mercury manometer 100mmHg Cuff reading of the monitor 100x3mmHg Reading of the manual mercury manometer 150mmHg Cuff reading of the monitor 150x3mmHg Reading of the manual mercury manometer 250mmHg Cuff reading of the monitor 250x3mmHg If an NIBP Simulator is available test the NIBP range and accuracy as follows Adult range and accuracy verification Systolic Diastolic Tolerance 60 30 5mmHg 80 50 5mmHg 120 80 5mmHg 150 100 10mmHg 200 150 10mmHg NOTE the uncertainty specifications of the NIBP Simulator must be added to the monitor tolerances for proper accuracy verification Test of over pressure 1 Connect a sphyg
34. UCTION 1 1 General MMED6000DP MG is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult pediatric and neonate Besides the user may select the different parameter configuration according to different requirements According to custom s order we have four types of this product standard type standar amp CO2 standard amp IBP standard amp Inner printer MMED6000DP MS can monitor vital signals as ECG RR SpO2 PR NIBP TEMP Dual channel IBP optional CO2 optional printer optional It integrates parameter measuring modules display and recorder in one device featuring in compactness lightweight and portability Large true color display provides clear view of 6 waveforms and full monitoring parameters Note This service menu is for standard type standard amp printer 1 2 Description of Abbreviation HR heart rate 2 channel ECG waveform SPO2 arterial oxygen saturation NIBP non invasive blood pressure IBP invasive blood pressure S systolic M mean blood pressure D diastolic PR pulse rate HR respiration rate 1 temperature channel 1 TEMP2 temperature channel 2 CO2 end tidal CO2 concentration 1 3 Explanation of Symbols AN Attention Refer to the relevant Class Equipment the prompt D Resistant defibrillator Heart Beat Detected BF type equipment o Power on off X Alarm off Silence Alarm on 2 Sound bcd Trend
35. ackaging Remove all the detectors leads and accessories and put them into the plastic bag Try to use the original packaging case and materials Any damage due to the improper packaging during the transportation shall be responsible by the user If you are still within the period of warranty please present the warranty card and one copy of the invoice or receipt Please present a written note detailing all the troubles when repairing the instrument 115
36. arameter quantity 1 cross screwdriver 1 2 M3x6 1 62 MMED6000DP M3 Operation instruction of core Operation step bills of raw and processed material 4 TFT display part SN Material code Name description quantity 4 after assembling install four M3x6 two direction copper pillars outside of the 1 11E3DL184363A Toshiba 8 4 TFT display supporting plate no inverter side tighten it with M3x14 assembling bolt then put TFT display in the supporting plate make M3x14 assembling bolt 2 1223100 3050 assembling bolt a P through the hole site of the screen tighten it with plain cushion spring 3 1223100M3140A plug screw M3x14 4 shim and nut 4 1221200 3060 Two direction M3x6 4 5 check self test 5 nut plain cushion each 4 spring shim bills of use tool TFT display SN name Specification type parameter quantity 1 cross screwdriver 1 2 1 picture16 TFT display assemble drawing 6 3 MMED6000DP M3 Operation instruction of core Operation step 5 main body sheet metal and power supply part assemble 1 put power supply module to the installation position through main body sheet metal pass power supply output cable through the front hole of the main body tighten it with M3x6 assembling bolt as picture 17 Main body Power supply mod
37. ata Bit 4 7 D5 Data Bit 5 8 D6 Data Bit 6 9 D7 Data Bit 7 10 ACK Acknowledge 11 BUSY Busy 12 PE Paper End 13 SEL Select 14 AUTOFD Auto feed 15 ERROR Error 16 INIT Initialize 17 SELIN Select In 18 GND Signal Ground 19 GND Signal Ground 20 GND Signal Ground 3 4 2 12 External power port of RTC real time clock J4 Pin 2 Definition ee as SND qpannsst external battery cathode anode 3 4 2 13 Port of external RESET J5 s Once the pin RESET and pin GND are short circuit the RESET will be finished Definition RESET GND 3 4 2 14 Port of speaker J6 s E Pin Name Definition 1 MIC Positive of speaker 2 MIC Negative of speaker 3 4 2 15 Power portJ3 Pin Name Definition 1 GND Power ground input 2 GND Power ground input 3 5V Power 5V input 4 5V Power 5V input 3 5 Keyboard CSN717 Connection drawing 3 5 1 General Description CSN717 is special keyboard for 6000DP MS3 The CSN717 PCB is shown as follows 3 5 2 Keyboard ports 33 CSN717 ports functions are described as follows Designator Function P2 Panel indicating light Fan and speaker control port connect to Pa power board P4 Serial port connecting to SN718 P5 Temperature sensor P6 Port of power board CSN510 3 5 2 1 P6 Power Board CSN510 Port Pin Name Definition 1 V 15V Power output of charge indication light 2 VBatt Battery power examination output 3 GND Ground 4 Bett ST Control of charge indication
38. board take them to the printer along the inferior main board as the picture then install the assembly to the installation pillar of the cladding panel module tighten them with M3x6 assembling bolt 5 Plug every cable to the socket in the board according to the hookup pack them in order assembly of power board and mainboard printer cable Nj hassembling bolt install nylon install copper pillar 801board embedded pilllar install nylon red insulating spacer pillar flat roof of cladding panel Picture 3 board assembly drawing MMED6000DP M3 Operation instruction of the unit bills of raw and processed material SN Material code Name pen e quantity 1 1223100M3060A assembling bolt M3x6 4 nut red insulating each 4 2 spacer kinds of cable 4 CS2 900 020JL hookup bills of use tool SN name Specification type parameter quantity sleeve 1 1 screwdriver Cross 2 1 anti static wrist 3 1 strap 82 MMED6000DP M3 Operation instruction of the unit Operation step bills of raw and processed material SN Material code Name description quantity 2 Install printer 1 11A51FA91354 1 Polish the position where is in the back side of the printer close A printer 1 e speaker with the file there is no conflict with the
39. by the external power the batteries voltage is low When the charging end the red light will light all the time 9 CALL Menu refreshing button when press this button you could exit current menu and return to the main menu and refresh the screen as well 10 The yellow button Power Supply on off switch 1 5 3 Side Panel 1 ECG ECG lead socket 2 SPO2 probe port 3 4 IBP1 IBP2 socket Reserved supply According to custom s order 5 NIBP Cuff and air tube port 6 7 T1 T2 Probe port two ports for selection 1 5 5 Rear panel e e eres e 0 o ae Fig 1 9 1 NET net access point connecting with the central monitoring system through the standard RJ 45 2 3 USB1 USB2 reserved 4 Speaker reserved 5 AUX OUTPUT reserved 6 VGA MONITOR CRT exteriorly connecting screen and standard VGA 7 Ground terminal Ground terminal of equivalent potential 8 Power AC Power supply 100 240V AC 50 60 Hz fuse 1 6A 1 6 Specification Environment The operation environment should comply with the following conditions Operating Temperature 5 C to 40 C Relative Humidity 0 to 80 non condensing Height of sea level 500m 4600m The transport and storage environment should comply with the following conditions Storage Temperature 10 C to 40 C Relative Humidity 0 to 90 non condensing Height of sea level 500 m 13100m Displa
40. ce 4 1 2 Standard accessories No Production Description Standard Quantity 1 MMED6000DP M3 Portable patient monitor 1 set 2 Choice reusable adult SpO2 sensor with extension cable 1 piece 3 Choice adult NIBP cuff with connector 25 35cm 1 piece 4 Choice NIBP extension hose with connector 1 5m 1 piece 5 Choice ECG cable with 5 lead wire and 6PIN connector AHA 1 piece 6 Choice TEMP skin probe 1 piece 7 Choice ECG electrodes 10 pieces pack 1 pack 8 jlriphase power wire 1 piece 9 Ground wire 1 piece 10 JBuild in battery 1 piece 11 Operation manual 1 piece 4 2 General Block Diagram CSN717 keyboard 220V Input Accumulator CSN510 LCD display Power board 1 Power Module 220Vac converted gt gt into 15Vdc CENTS Vie e gt Mainboard Printer r SPO2 ECG NIBP amp 801 Function m interface A 37 4 3 Installation 4 3 1 Front Panel Installation 4 3 1 1Catalogue of task instruction Product Name Multi parameter monitor Product Model MMED6000DP M3 Working Operation name procedure panel installation Version Changing contents 1 Install key boards A01 2 Install alarm light board pol 3 Install transparence 401 board and button 4 Self test A01
41. cture 3 ledger plate and stick harness assemble show dot 1 fluid sealant 50 MMED6000DP M3 Operation instruction of core Operation step bills of raw and processed material 1 Install the sheet metal part of main body quant 4 install the Fixup corner piece of network card connector to the network card Malena coop Name ebecrpuen ity connector with M3x6 plug screw as picture 4 Network card 5 install the network card board to the main body tightening it with M3x6 plug screw 1 260028980200B connector 1 1 2 322918044002A Fixup corner piece 1 3 1223600M3050A plug screw M3x6 4 Fixup corner piece bills of use tool Network card connector qu SN name Specification type parameter y 1 Sleeve and 1 screwdriver 2 cross screwdriver Picture 4 network card connector assemble drawing 51 MMED6000DP M3 Operation instruction of core Operation step 1 Install sheet metal part of main body 6 remove the nut plain cushion and soldering terminal which are belong to BNC terminal take terminal nob through the main body where is the position to be installed Then pull on the plain cushion and soldering terminal to the Terminals Tightening it with own nut dot little gas thread fluid sealant to nut as picture 5 7 install DB1 to the main body the same as the sixth step as picture 5 8 install DC fan to the main body tight
42. d be returned to us expect for special reason 3 Spare machine for repair it is used to replace the damaged machine for customer using customer should send the damaged machine to us to repair 4 Repair for sponsoring and contributing machine customer should send the machine to us to repair 5 Updating software is free 10 2 Exemption and restriction 1 Warranty does not apply to the damage or loss sustained due to well known act of god such as fire earthquake flood thunder cyclone hail electrical storm blast building collapse commotion etc 2 Non service items D The cost and insurance of dismantling and testing overhauling reinstall transfer moving the instrument or parts 2 Damage or loss sustained due to inspected or repaired by other institute that is not certified 8 Damage or alteration by anyone other than our company authorized service personnel 3 The damage or lose sustained due to connection to peripheral equipment such as printer computer etc that are not provided by our company are not covered by the warranty 4 Obligation restriction In the duration of warranty if the operators use other fittings that are not provided by us we reserve the right to cancel warranty 10 3 Customer guarantee 1 Read the user manual in details before operation 2 Operation and maintenance according to the user manual and guarantee the requests of power and environment 10 4 Non warranty and non replacement polic
43. en external cabinet Unscrew the fixing screws from the rear panel of monitor ERA OEN 3 D i H si n FA A P 4 5 spore LUI NR A 738 gown a Mane G G SS gol PT t Fig 8 3 Fig 8 4 109 8 3 Other parts disassemble order After disassembling the battery disassemble other parts according to the following order Disassemble Disassemble Disassemble LCD Keyboard the machine core module 8 3 1 Remove the cables from key board Fig 8 5 8 3 2 Use screwdriver to remove the screw and remove the TFT Fig 8 6 8 3 3 Use screwdriver to remove the main board and power board Then you could see the picture of Fig 8 7 Fig 8 7 8 3 4 Remove the four screws from the back panel Then the machine core could be removed out from the panel CHAPTER 9 CLEANING AND DISINFECTION NOTE Before cleaning the monitor or the sensor make sure to turn off the power and disconnect the AC power 9 1 Maintenance checks Before using the monitor do the following 1 Check if there is any mechanical damage 2 Check all the outer cables inserted modules and accessories 3 Check all the functions of the monitor to make sure that the monitor is in good condition If finding any damage on the monitor stop using the monitor on patient The overall
44. ening it with M3x25 sunk screw as picture 5 9 check self test if every fix module is assembled in place screw and accessory are leak or not take the quality products to the turnover warehouse bills of raw and processed material SN Material code Name description p 1 11X93CQ950J5A BNC terminal socket 1 2 11B31KD1204PA DC fan 40x40x20 1 3 11W3600DB150A DB15 socket Match 1 Imperia nut 4 1223400M3250A sunk screw M3x25 4 5 1222200M3000A nut M3 E 6 plain cushion bills of use tool SN name Specification type uid quantity 1 Sleeve and 1 screwdriver 2 52 e Network card co AS Sheet metal part of main body printer ledger plate Battery lock tube 5 main body assemble drawing 53 MMED6000DP M3 Operation instruction of core Operation step 1 Install pump and valve part 1 weld the pump valve cable which has plug to the pin of the pump through the heat shrink tube then push the heat shrink tube to the root of the pin and heat it with calorifier synchronously dot little hot melt adhesive at the root of the pin as picture 6 and 7 2 after setting aside 120mm of valve s own down lead shuck off 3 5mm line leather press terminal plug PTK plug pin up with hot melt adhesive picture 7 valve cable finish welding drawing bills of raw and processed
45. erature PROBE OK gt Replace PROBE YES NO Reconnect connector Is connection OK NO Check source Is supply voltage OK pply g Change CSN801 board 95 NO RESPIRATION READING NO p Replace PROBE Are ECG cable and lead wires OK NO Are electrodes be placed OK Replace electrodes Is respiration type same as the internal setup Select the respiration type correctly Change CSN801 board 9 6 NO SPO2 READING NO OK p Replace SPO2 sensor NO Reconnect connector connection Is OK Change power Is supply voltage OK 9 source Change CSN801 board 97 5 2 Troubleshooting 5 2 1 The main trouble of ECG HR Failure Possible cause Solution Display shows ECG CSN801 board has Replace the CSN801 board ERROR when you turn on problem the equipment No ECG waveform D Poor connection of ECG D Use new electrode to electrode films ensure good contact RL electrode is 2 Connect RL electrode suspended CSN801 board Replace it damaged 4 Note the precondition of The patient s skin is too skin dry ECG waveform is abnormal DElectrodes are connected Correctly connect or has interference incorrectly electrode There is suspending Remove electrode that electrode are not used AC power has Use power gro
46. for selection High level when alarm occurs the color of the indicator becomes red and starts flashing once every one second Mid level when alarm occurs the color of the indicator becomes orange and starts flashing once every one second Low level when alarm occurs the indicator would be turned on continuously and its color becomes orange all the time 2 Silence Silence setting button when press it the alarm of Monitor will be off 3 Freeze Freeze setting button During the waveform scrolling period when press this button the waveform will be stopped for further observation 4 NIBP Start cancel BP measuring when press this button Monitor will carry out command to measure patient BP condition press this button again during the BP measuring period and then the BP measuring action is terminated 5 Print Printer button when Monitor equipped with printer which could be internal thermal array recorder or printer as a peripheral and then press the button the correspondent data will be printed out 6 Rotary knob User rotate this knob to select and enter desired item it is similar in function with PC mouse For more information please refer to section of Menu operation 7 Power supply indicator green light Demonstrate power supply status the power supply is from AC power supply or rechargeable batteries 8 Indicator of batteries charging state red light The indicator will turn on flashing only when the monitor is powered
47. he unit Operation step 1 Install core 2 plug SPO2 T1 T2 and ECG cable plug to P105 P252 and P200 socket of 801 board pack them 3 pass the connecting strip with M3x8 nut and red insulating spacer through the component side of two board through the hole site of the connector at last pull on the plain cushion tighten it with nut form the two board into a single unit X 8 screw red insulating spacer connector Welding side of mainboard Component sid of power board _ ALD n nut red insulating spacer picture2 two board assemble drawing bills of raw and processed material SN Material code Name quantity 1 260002932021A 510 power board 1 2 11A1244963V0A mainboard 1 3 182510000000A M3 board connector 2 4 122360M3080A screw M3x8 4 5 1222200M3000A nut M3 4 1322100000D3A red insulating spacer 8 bills of use tool SN name Specification type quantity 1 Sleeve screwdriver 1 2 Cross screwdriver 1 3 anti static wrist 1 strap 81 Operation step 1 Install main board core 4 after assemble plug printer cable to the relevant position of main
48. hout any error messages when powering monitor on 6 3 Front panel test 6 3 1 Rotary knob test Rotate the knob in the clockwise direction while verifying that the highlight moves from icon to icon with a clockwise movement Rotate the knob in the counter clockwise direction while verifying that the highlight moves from icon to icon with a counterclockwise movement Highlight any parameter icon rotate the knob clockwise in the parameter area verify that the movement of cursor is from up to down Highlight any parameter icon rotate the knob counter clockwise in the parameter area verify that the movement of cursor is from down to up Highlight the RETURN menu item press the knob and verify that the menu is return to the superior menu 6 3 2 Verification of Keyboard control 0 Press ALARM key observe that the alarm icon in frame of menu status will change Press SILENCE key observe the silence icon in frame of menu status will change Press FREEZE key one channel of the ECG waveform should be frozen Press START key will start NIBP measurement and press the key again will cancel this measurement Press PRINT key it can print the relevant waveform and measured data if the printer is installed Press MENU key the display is refreshed 102 6 4 pudo system test Set the simulation item ON the detailed operation please refer to the Section 9 5 ECG Menu of Operator s Manual Select O
49. ical at 25 C no printing one NIBP measurement per 15 min CHAPTER 2 SPECIAL OPERATION IN MENU Some operations of monitor aim at the dealer but not the doctor such as Language setup or Hz selection the dealer should note the following points before monitor getting end user NOTE you must keep the correct setup according customer s condition before using the equipment ni In monitoring status rotate the knob to highlight the MENU icon and then press the knob the menu bar of system setup appears on the bottom of screen IA Time VOLUME PRNSETUP COLOR P ISPMODE NEAT ES Fig 2 1 Rotate the knob and select EXTEND item to access the sub menu shown as below BED RETURN ER Fig 1 2 Fig 2 2 The functions of the items in the submenu please refer to Operator s manual Select SYS ACC item to access the sub menu shown as Fig 2 3 ORD NUM 4 TH HUMH W EHTER RETURH Fig 2 3 Then Input 2 in each of the items press PW ENTER to enter another sub menu shown as Fig 2 5 Fig 2 4 Fig 2 5 Rotate the knob to select SETUP menu to enter in the sub menu shown as Fig 2 6 50Hz ACCHOICE 85 Fig 2 6 Language Setup The system offers two languages English and Chinese Technician is able to set the required menu as per customer s demand ACCHOICE It is the AC 50HZ or 60HZ filter CHAPTER
50. installation Operation step 1 install the knob of the back cover 1 put the rubber stabilizer to the small square groove of bottom shake it lightly if feeling flexible please stick it with little 502 gluewater 2 button knob1 and knob2 oppositely tighten it with PA3 0x8 plug screws of self threading as picture 1 a 3 install the knob to the top of the back cover tighten it with PA3 5x12 plug screws of self threading as picture1 b knob1 Enclose PA3 0 X 8 knob2 K 1a knob assembled picture Knob module Back cover O 8000 PA3 5x12 bills of raw and processed material SN Material code Name ue TM 1 32291804401A M3 back cover 1 2 131553331001A knob 1 1 1315533310024 Knob 1 plug Screws of 2 4 1223600PA3008A self threading PA3 0x8 plug screws of 2 5 122360PT3512A self threading 5 12 6 131110000000 rubber stabiliser 4 Bills of use tool SN name Specification type parameter ud 1 protective gloves Small cross screwdriver 7 3 picture1b knob assemble completion picture MMED6000DP M3 Operation instruction of back panel Operation step 2 Install side panel 1 Install the six core plastic ECG connector plugs to the shoe plate then tighten it with PA2 3x6 5 tapping screw 2 Install the SPO2 and BP sockets to the hole site of the shoe plate respectively SPO2 s
51. is damaged rotary encoder Connecting wire of Replaced repair keyboard is damaged connecting wire of keyboard Sound is raucous or there is Keyboard failure D Replace keyboard no sound Speaker or connecting Replace speaker wire failure connecting wire Recorder cannot execute 1 Recorder has no paper D Install paper printing operation Recorder failure Replace the recorder Connecting wire of the Replace or repair the recorder is damaged connecting wire of the 4 The model of printer has recorder been set incorrectly Set the mode of printer correctly Record paper goes out recorder installing or Adjust the installation of skew positioning recorder Cannot be linked into D Network linking wire is Check and repair network damaged network linking wire Main board failure 2 Replace main board 5 2 8 Other troubles Failure Possible cause Solution Rechargeable battery does The battery is D Charge for over 24 not charge exhausted hours The power board is Replace the battery and damaged the power board Some parameter areas are The color setup is incorrect Reset the color of blank parameter Not enter the monitor status Password is locked Pressing START twice PRINT once release lock Start the monitor the monitor can check automatically but it still stays starting Rom Dos
52. isplaying port J3 Power port External Power port of RTC real time clock J5 External reset port J6 Speaker port J8 USB port J9 COM port J10 port J11 COMS port J12 COMA port 3 4 2 1 Jumper setting Jumper as a simple electronic switch contains two metal pin and a small sheet metal which in a plastic cover It realizes the switch function by short circuit the two metal pin through the sheet metal 3 42 Open Closed Closed 2 3 3 4 2 2 JP1 Selection jumper of Dummy display the EMS memory mode electronic disk write protect JP1 TE Status Closed default status A disk startup Open C disk startup Closed defaultstatus 3 4 Allowing dummydispay Forbidding dummy display Closed default status 1 44M electronic disk write protect System disk 3 4 2 3 COM1 COM2 COM3 COM4 Port jumper port of TTL and 232 2 6 JP2 JP4 JP5 JP6 1 5 Status _ Function 2 4 Closed 232 LEV level output 3pin 5pin Closed Closed _ TIL LEVlevelouput 4pin 6pin Closed 3 4 2 4 TFT LCD Port JP3 selection jumper of power voltage 5V 3 3V JP3 mes Status Function 1 2 Closed Default status LCD power supply is 3 3V 2 3 Closed LCD power supply is 5V 3 4 2 5 COM1 COM2 COM3 COM4 port TTL amp 232 port J9 J10 Jill 5 We Pin EC 7 MEN Fc To RN Definition 3 4 2 7 IDE port DOM port CON1
53. l film drawing bills of raw and processed material SN Material code Name CES E quantity 1 320008610001A cladding panel film 1 1 2 320008610002A cladding panel film2 1 3 4 5 bills of use tool qu SN name Specification type parameter nti 1 stainless steel 150mm ruler 2 scissor 1 3 5 7 MMED6000DP M3 Operation instruction of core Operation step 3 Install pump and valve part 6 Stick the film 1 to the flat roof of the cladding panel no pump and valve side stick film 2 to the cladding panel vertical plane To the sensor of the function board To BP socket of interface board 2xcs nao 45 6 film1 veneering cladding panel vertical plane Picture 11 film stickup position drawing bills of raw and processed material SN Material code Name quantity 1 320008610001A cladding panel film 1 1 2 320008610002A cladding panel film2 1 3 1316100W10MMA double face tape bills of use tool SN e qua name Specification type parameter tity 1 scissor 1 2 3 58 MMED6000DP M3 Operation instruction of core __ Operation step 1 Install pump and valve part 7 put red insulating spacer in the hole site of embedded pillar screw M3x6 nylon pillar then put CSN801 board to the embedded double screw bolt tightening it with M3x20 n
54. lity of electrode 3 The position of electrodes skin 2 Replace electrodes 3 The electrodes should not be too close the new No RESP wave The mode of RESP is wrong Select Impedance type in RESP mode 5 2 3 The main trouble with TEMP Failure Possible cause Solution TEMP value is incorrect Measuring sensor is poorly Connect TEMP sensor connected stably The measuring data is low The measuring time is D The measuring time short should be long 2 The position of probe Move the position of probe 5 2 4 The main trouble of Blood pressure Failure Possible cause Solution NIBP cuff cannot be inflated 1 Air way is folded or has t Adjust or repair the air leakage way 2 The keyboard is bad 2 check the cable or replace it Blood pressure cannot be measured occasionally Cuff becomes loose patient is moving Keep the patient quiet bind the cuff correctly and safely Error of blood pressure measurement is too great Cuff size does not fit the patient Use the cuff with appropriate size Cuff inflates repeatedly but no data Pressure board or the deflation valve have trouble cuff and the inner pipe of monitor have leakage Using other cuff check if the cuff is leak If the cuff is excellent you should check if the gas pipe is leak Finally replace the pressure board and deflation valve 5 2 5 The main trouble
55. menu System setup menu 50 60 HZ Equipotential grounding C CE approval terminal gt This symbol indicates that the instrument is IEC 60601 1 Type CF equipment The unit displaying this symbol contains an F type isolated floating patient applied part providing a high degree of degree of protection against shock and is suitable for use during defibrillation 1 4 Special Features Portable compact AC power and internal rechargeable battery Resistant high frequency electrotome design reliable and special module is used in operation room Optional inner printer with 3 channels wave or external printer Adjust volume more accurately by digital system Menu design adopts Huffman decode operating more effectively Support Ethernet wireless LAN and could connect with Central monitoring system option 1 5 Appearance of Monitor 1 5 1 Front panel The display of MMED6000DP patient monitor is TFT LCD which displays the patient parameters waveforms historical data and monitor status The screen is divided into five areas monitor status waveforms the table of historical data parameters menu as well as frame of menu status oooeooootvt Fig 1 1 1 Alarm Indicator If there is physiological alarm it demonstrates that some parameters measuring scale is beyond alarm limitation in the meantime the indicator begin flashing According to the various alarm level there are three alarm level in all
56. momanometer to the NIBP inflate port as following figure connector pressure transdusor 2 If the patient selection is NEONATTE located under the NIBP icon perform the following to select ADULT a Turn the Rotary Knob to highlight NIBP icon b Press the Rotary Knob to select NIBP menu Turn the Rotary Knob to highlight MODE selection d Press the Rotary Knob and select AUTO selection 105 3 Perform the following to set CAL ON a Turn the Rotary Knob to highlight NIBP icon Press the Rotary Knob to select NIBP menu Turn the Rotary Knob to highlight ALARM selection Press the Rotary Knob to select ALARM selection Turn the Rotary Knob to highlight CAL selection Press the Rotary Knob to select CAL selection Turn the Rotary Knob to select ON selection Clos 4 Inflating the cuff manually by pressing the rubber ballonet With the pressure rising the reading of sphygmomanometer is higher When the pressure over 280mmHg the valve should deflate 6 11 SPO2 test D Connect SPO2 Probe to the SPO2 connector on the monitor side panel Insert the operator s finger into the finger sensor the SPO2 measured value of healthy person should be from 95 to 99 and the pulse rate is same as heart rate the waveform of the SPO2 is smooth with no step 9 If SPO2 Simulator is available verify the accuracy of Oxygen Saturation Value with probes as follows Oxygen Saturation Tolerance 96 2 86
57. ng Operation name version Changing contents procedure installation of unit 1 Install the core Aot 2 Install printer 501 3 Install TFT module ADI 4 install panel module A01 5 self test 2 Work Procedure Flow Chart Of installation of the unit Turnover warehouse Install printer Y Standby application gt N Disqualification return Install main machine od MMED6000DP M3 Operation instruction of the unit Operation step check 1 each module is eligibility no leaking 2 there are no crack and evident damnify in the panel and back cover no bad lead 1 Install core 1 install the core to the back cover adjust every port to the portiforium of back cover Tighten it with M3x8 assembling bolt in the hole site according to the drawing Then tighten it with assembling bolt in the D hole at last install it to the top of the back cover and tighten it with PT3 5x15 plug screw M3x8 plug screw A hole D hole picture1 screw installation position drawing bills of raw and processed material SN Material code Name description quantity 1 core module 1 2 back cover module 1 3 1223100M3080A plug screw M3x8 6 Bills of use tool SN name Specification type parametg quantity r 1 cross screwdriver 1 8 0 MMED6000DP M3 Operation instruction of t
58. ocket must be higher 8 9 5mm than the shoe plate After finishing these two steps seal the foreseen hole of the port shoe plate with the sealing joint strip put them on the installation position where the right side of the back cover is Adjusting the coaxiality of the hole site in the SPO2 socket and shell tighten them with PA2 3x6 5 tapping screw which is pulled on plain cushion 3 Wrapping up two temperature sockets in PVC sealing joint strip install the temperature socket which is welded yellow line to the left side of the shoe plate namely the hole site of T1 install the socket which is welded red line to the right side of the shoe plate namely the hole site of T2 picture 2 bills of raw and processed material SN Material code Name description quantity 1 131530781001A Port facing bar 1 2 3100066441151A CSN801 ECG Cable 1 3100066441150A CSN801SPO2 cable 1 31000664411149 CSN801 temperature 1 A cable 11X94DNR0130A metal socket of BP 1 6 122360 2365 tapping screw PA2 3x6 5 6 ECG socket Iu Four PA2 3x6 5 sealing joint strip of 1 7 PVC inflaming 1nish installation retarding show Bills of use tool Four SN Name Specification type parameter uc 1 Small 1 tapping cross screwdriver SCTEW 2 spanner 1 the shoe plate SPO2 socket C 8 9
59. osable TEMP probe must be recycled or disposed of properly 9 6 SpO2 sensor cleaning and disinfection NOTE Do not subject the sensor to autoclaving Do not immerse the sensor into any liquid Do not use any sensor or cable that may be damaged or deteriorated 1 Use a cotton ball or a soft mull moistened with hospital grade ethanol to wipe the surface of the sensor and then dry it with a cloth This cleaning method can also be applied to the luminotron and receiving unit 2 The cable can be cleaned with 3 hydrogen dioxide 7 isopropanol or other active reagent However connector of the sensor shall not be subjected to such solution 113 CHAPTER 10 WARRANTY 10 1 Warranty and repair 1 Repair response time AM9 00 to PM17 30 on Monday to Friday except legal holiday Repair time AM9 00 to PM17 30 on Monday to Friday except legal holiday 2 Repair service Including telephone support field inspecting fittings replacement Telephone support we can give guidance to customer s engineer to inspecting the instrument when you dial our service line 86 10 86863551 Professional repair engineer online provides technical support Field inspecting we will send engineers to repair the instrument if necessary Certified engineers of our company or local repair team trained by our company provide this service Fittings replacement if necessary we will replace the damaged fittings according to contract The damaged fittings shoul
60. ould be 96 8 Set the SPO2 high limit as 90 low limit as 80 4 Set the SPO2 alarm as on Verify the SPO2 visual and auditory alarms the SPO2 data should flash and du du voice should be heard 6 Disconnect the ECG Patient Simulator 6 7 ECG test 103 D Attach the lead to the ECG patient simulator 2 Set the patient simulator to output a 1mV 10Hz sine wave set the wave of ECG submenu as 10mm Mv the ECG waveform should show the sine wave that the height is 10mm 8 Set the patient simulator to output a 1mV QRS pulse at 60bpm set the lead of ECG submenu as ll 4 Verity the ECG waveform moving QRS pulses without jittering the number indicate an ECG count of 60bpm Set the patient simulator to output a 1mV QRS pulse at 120bpm verify the ECG waveform moving QRS pulses without jittering and the number indicate an ECG count of 120bpm 8 Set the patient simulator to output a 1mV QRS pulse at 240bpm verify the ECG waveform moving QRS pulses without jittering and the number indicate an ECG count of 240bpm Set the patient simulator to output a 0 5mV QRS pulse at 30bpm verify the ECG waveform moving QRS pulses without jittering and the number indicate an ECG count of 30bpm Set the patient simulator to output a 2mV QRS pulse at 240bpm verify the ECG waveform moving QRS pulses without jittering and the number indicate an ECG count of 240bpm 6 7 1 ECG LEAD OFF test Perform the following procedure to verify
61. pan Accuracy xammHg Mean difference xbmmHg Standard deviation 8mmHg Typically 25seconds Varies with patient s pulse rate pulse pressure and amount of artifact present Automatically releases cuff pressure if inflation pressure exceeds 280mmHg 150mmHg Stop determinates if the measurement time exceeds 120s 90s Pressure high and low limits alarm delay 7s Resistance method RA LL 2 60 rpm 1 rpm Respiration rate high and low limits alarm delay 7s Resistance 2 T1 and T2 F Or C Resistive recta and skin reusable and disposable YSI 400 Series types 0 50 C 0 1 C during the 25 C 45 C the measuring errors 0 2 C Body temperature high and low limits alarm delay 7s CO2 Optional Technique Side Stream non dispersive infrared NDIR absorption technique Including multiple water trapped filtration system and microprocessor logic control of sample handling and calibration Measurement Range Respiration rate Accuracy Flow rate range IBP Optional Range Sensitivity Gain Accuracy Bandwidth Power Requirements Power Supply Internal Battery Operating Time fully charged battery 0 99mmHg 1 99 breaths per minute 3 mmHg 0 40 mmHg 8 of reading 41 76 mmHg 10 of reading 77 99 mmHg User selectable variable from 90 to 200 ml min defaults to 175 ml min 50 to 350mmHg 5uV V mmHg 0 5 0 to 12Hz 100V 230V 10 50 60Hz 12V 7AH Type sealed lead acid 2 hours typ
62. r socket LSN 17 D cec cse cir Dis u Xs1printer L35power inverter network card port Picture 4 Bx wj koe e 1350 Li take off back cover 5 02 take off back cover Ti 2 take off back cover ECG pump cable printer data cable Q csee Vesport unit hookup and trace table SN Cable name from To Descr Quant yiption 1 power cable of 801 function board Power board P9 CSN801board P11 4P 1 2 Main board power supply Power board P11 a board power 4P 1 3 3 M3 printerTR50power cable Power board P8 Printer power 4P 1 4 M3 inverter SAKQ012A cable Power board P10 inverter 2P 1 5 de port from mainboard to key Power board P1 Key board P6 8P 1 6 ial port from mainboard to key Power board P4 Mainboard J10 3P 1 7 Fan and speaker control line Power board P3 Key board P3 4P 1 8 Battery cable Power board P4 Battery cable 2P 2 96 1 9 Power adapter to CSN510power connecting Power board P2 Switch power 4p 1 output 10 AC power cable Socket without fuse Switch power insput 5P 1 11 VGA port cable main board CON2 VGA port BD15 1 12 M3 valve power cable CSN801board J2 pump pinout plug 2P 1 13 SPO2 cable 801board P105 Side panel SPO2 6P 1 14 Temperature cable 801 board P252 Side panel T1 T2 5P 1 15 ECG cable 801 board P200 Side panel ECG 6P 1 16 M3 valve power cable 801 board J1 J
63. re to turn off the power and disconnect the AC power If ECG cable is damaged or aged replace with a new ECG cable 1 Cleaning I2 MMED6000DP monitor and sensor surface can be cleaned with hospital grade ethanol and dried in air or with soft and clean cloth 2 Sterilization To avoid extended damage to the equipment sterilization is only recommended when stipulated as necessary in the Hospital Maintenance Schedule Sterilization facilities should be cleaned first 3 Materials recommended for use in sterilization Ethylate 70 ethanol 70 Acetaldehyde 4 Disinfection To avoid extended damage to the equipment disinfection is only recommended when stipulated as necessary in the Hospital Maintenance Schedule Disinfection facilities should be cleaned first 9 5 TEMP sensor cleaning and disinfection 1 The TEMP probe should not be heated above 100 C 212 F It should only be subjected briefly to temperatures between 80 C 176 F and 100 C 212 F 2 The probe must not be sterilized in steam 3 Only detergents containing no alcohol can be used for disaffection 4 The rectal probes should be used if possible in conjunction with a protective rubber cover 5 To clean the probe hold the tip with one hand and with the other hand rubbing the probe down in the direction of the connector using a moist lint free cloth NOTE Disposable TEMP probe must not be re sterilized or reused For protecting environment the disp
64. sparent board take off 1 131536351002A M3 TFT transparent 1 ie self adhesive paper around the board stick it to the board board Install the rotate knob to the screw rod of the coder then circumgyrate it 2 131543371001 M3 rotate knob 1 several times feel smooth is better 3 330088171029A M3 panel label 1 Stick the panel label to the last cell groove of the panel label position TES bills of use tool SN Name Specification type parameter 1 1 protective gloves 415 label position 2 test records 3 technics file Self test 45 4 3 1 2 Assemble Drawings of Front Panel Y V altel ra i L L page 1 W 1 pea 54 123 020 Picture 1 CS6 644 1197 Picture 2 4 3 2 Machine Core Installation 4 3 2 1 Catalogue of task instruction Product Name Multi parameter monitor Product Model MMED6000DP M3 Working Operation name version Changing contents procedure installation of back cover A01 1 install sheet metal part of main body A01 2 install pump and valve part P amp V 3 install power supple part 4 install TFT display part AM 5 Assemble main body and power part A01 6 Assemble main body and P amp V part 01 7 self test A01 Turnover warehouse Install power part In
65. stall TFT display part main body Install P amp V Assemble main body and P amp V part Standby application body and power part Disqualification return MMED6000DP M3 Operation instruction of core Operation step 1 Install sheet metal part of main body 1 install printer ledger plate to the main body sheet metal tighten it with M3x6 assembling bolt As picture 1 2 put in the battery stick harness from square edged orifice of lock tube pull on spring to the lock pillar though the round orifice of top lock tube tightening it with M3 nut dot little fluid sealant in it As picture 2 3 install the battery lock tube which is assembled nicely to the main body tightening it with M3x6 assembling bolt As picture 3 picture1 ledger plate and stick harness picture2 stick harness module assemble drawing assemble drawing bills of raw and processed material SN Material code Name quantity 1 320080370101A Main body 1 sheet metal 2 122730481012A Printer ledger plate 1 3 320008008001A Battery lock tube 1 4 320008009001A Battery stick 1 harness 5 322768382004 Battery lock spring 1 1223100M3060A assembling bolt 4 M3x6 1222200M3000A Nut M3 1 gas thread fluid sealant Bills of use tool SN name Specification type apes uo 1 Sleeve 1 screwdriver 2 cross screwdriver 1 lt Pi
66. tion type 1 cross screwdriver 1 1 Film 2 he Film 1 SN name parameter quantity port sheet metal M3x6 assembling bo Picture 14 power part assemble drawing MMED6000DP M3 Operation instruction of core Operation step 4 TFT display part 1 put M3x6 nylon pillar in the installation hole through the component of the inverter tighten it M3 nut with red insulating space 2 daub the heatconducting silicone grease to the component of T1 T2 which is in the inverter mark with 689D435 writing in the surface 3 put the inverter to the supporting plate s installation position separate L1 the component which is marked 101 writing in the surface from supporting plate with insulating cloth then tighten it with M3x6 assembling bolt Install nut in the b gt Red insulatin The position silicone grease is daubed Inverter board L1 component FT display supporting plate insulating cloth Picture 15 inverter assemble process drawing bills of raw and processed material SN Material code Name description niit 1 322918038012A TFT display supporting plate 1 1 2 11U22KQ012A1A double lighting tube inverter 1 1 3 1221200M3061A nylon pillar M3x6 3 4 1222200M3000A nut M3 3 5 122510HGZD30A Red insulating spacer 6 Heatconducting silicone grease bills of use tool SN name Specification type p
67. unding wire CSN801 board is Replace it damaged Only one or some leads Some electrodes Connect the lead with ECG could display waves some not contacted well simulator if the signal is leads display straight lines The lead wires normal the trouble lies in damaged the electrodes or leads 8 The CSN801 board has identify which electrode problem should be changed if the signal is abnormal still change the CSN801 board ECG waveform displays D Patient is moving Keep patient quiet disorderly constantly Position of electrode 2 The electrodes should not be too close 8 The mode of monitor 3 Select the right mode of monitor Grounded receptacle Connected with grounded receptacle HR data fluctuate Patient is moving Keep patient quiet remarkably constantly ECG base line is Power supply is inferior Do not use the same power smooth panel with high power equipment 5 2 2 The main trouble with RESP Failure Possible cause Solution No RESP waveform Electrodes are D Use RL LL electrode RESP waveform is connected incorrectly connect to the correct abnormal Patient is moving position constantly 2 Keep patient quiet CSN801 board 15 9 Replace it damaged The data change The dryness of skin Note the precondition of 98 remarkably and have deviation from the real data Inferior qua
68. y The work environment is not eligible For example if the relative humidity exceeds 70 circuit boards of the instrument may be damaged due to condensate If voltage of power supply is fluctuant and exceeds 240VAC the power adapter may 114 be damaged There is smear or marks that are not belong to the instrument and cannot be removed from the outside surface of the instrument The instrument or its fittings are mechanically damaged The circuit is short and damaged due to liquor or other stuff flow in the instrument or its fittings All probe and its accessories are not free replacement Leakage of air cell of blood pressure sleeve due to improper storage or operation is not free replacement The malfunction with result form improper repair by anyone other than our company authorized service personnel The malfunction with result from improper use 10 5 Customer special warranty period Due to we stipulate the warranty period according to the relevant electronic regulation of country which we stipulate is on year accessory is three months When customer requires to extending the warranty period you should consider whether it is reasonable Because electronic product quickly replace as to the warranty period over three years purchased accessories may be out of stock In this case we will adopt to entirely upgrade or replace the old you should pay the minimum acceptable cost of renewed device 10 6 Rep
69. y Type 800 600 pixel color TFT Screen Size 8 4 inch diagonal Displayed Parameters Time Battery backed quartz crystal clock Alarms ECG Heart Rate NIBP Pulse Oximeter Respiration Rate Trends Temperatures Trace Freeze ECG High and low limits selectable on patient parameters ECG Waveform Scale displayed lead Derived from ECG OR SpO2 Pressure systolic mean and diastolic Pulse Rate Pulse waveform and percent saturation Respiration rate derived from ECG Heart rate respiration rate NIBP systolic mean diastolic Temperatures and SpO2 Two channels Traces A or B Protected against defibrillator and electro surgery potentials Standard Lead Display Gain Scales Sweep Speed Input Resistance Frequency Response Common Mode Rejection Ratio Electrode Offset Potential Baseline Recovery Heart Rate range Resolution Accuracy Alarm Lead Off condition ST segment ST segment range Accuracy Spo2 Display range Accuracy LED Specifications Alarm delay Display Update Resolution Pulse Rate Measurement Range Resolution Accuracy Alarm delay NIBP Technique Patient Types Cuff Inflation Time 1 II 1 aVL aVR aVF V 2 5mm mV 5bmm mV 7mm mV 10mm mV 15mm mV 20mm mV 25mm mV 12 5mm s 25mm s 50mm s gt 5M Ohm at 10 Hz not including patient cable 0 05Hz 100Hz 3dB gt 60dB Maximum 0 3V lt 5s after 5KV defibrillation 15 to 300bpm 1bpm
70. ylon pillar to the installation hole site of CSN801board Synchronously install the M3x20 copper pillar which has nut to the installation hole site where the right side of the cladding panel is 8 plug the pump and valve cable to the relevant plug according to the hookup plug 4P power cable to P11 item of CSN801 board plug 3Psignal cable to P10 item of CSN801 board 9 check self test M3x20 Nylon pillar 3x20Nylon pillar Red insulating spacer M3x6 Nylon pillar M3x20 Copper pi Flat roof of cladding panel Picture 12 CSN801board assemble drawing bills of raw and processed material SN Material code Name description quantit 1 260020831012A CSN801 board 1 2 Power cable signal cable 4P each 1 3 1221200M3200A Copper pillar M3x20 4 4 1221200 3201 Nylon pillar M3x20 2 5 1221200M3061A Nylon pillar M3x6 2 6 1222200 3000 M3 nut 1 7 132210000003 Red insulating spacer 3 2 bills of use tool SN name Specification type parameter re 1 static free wrists trap 1 2 Sleeve and spanner 1 5 9 MMED6000DP M3 Operation instruction of core Operation step bills of raw and processed material 1 Power part quantit 1install the power plug with cable to the squareness portiforium of the SN Material code Name description y port sheet metal tighten it with M3x8
71. ymbols Special feature Appearance of monitor Specification Chapter 2 Special operation in menu Chapter 3 Monitor function and principle Connection drawings Power supply unit CSN801 board CSN718 Mainboard CSN717 Keyboard Chapter 4 Component and structure Component General block diagram Installation Front panel assembling Machine core assembling Back panel assembling Unit assembling Chapter 5 Troubleshooting Diagram of solutions to various troubles Troubleshooting Error Message Chapter 6 Calibration of monitor Required testing tool Power on the monitor Front panel test Audio system test Test of automatic storage Alarm test ECG test Respiration test Temperature test NIBP test SPO test Chapter 7 Adjustment procedure ECG adjustment NIBP adjustment SpO2 adjustment Chapter 8 Disassembly procedure Battery Disassembly Monitor Disassembly Other parts Disassembly Chapter 9 Cleaning and Disinfection Maintenance check General cleaning Sterilization Precondition and cleaning TEMP sensor cleaning and disinfection SpO2 sensor cleaning and disinfection Chapter 10 Warranty Warranty and repair Exemption and restriction Customer guarantee Non warranty and non replacement policy Customer special warranty period Repackaging 104 105 106 107 107 107 108 109 109 109 110 111 111 111 112 112 113 113 114 114 114 114 114 115 115 CHAPTER 1 INTROD
Download Pdf Manuals
Related Search
Related Contents
VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R HSM Classic 450.2 2x15mm Copyright © All rights reserved.
Failed to retrieve file