Home
SERVICE MANUAL MODEL SSP-350-X-39
Contents
1. Network Line Cord Ferrule 8 32 x 3 8 Security Screw 2 screws are needed per unit Security Tool for screw above Mounting Box Power Supply Modular Jack Interface modified 1 jack per pair of units CEECO 7 Communication Equipment amp Engineering Company PROPRIETARY 9 0 ISSUE 4 0 REPAIR AND RETURN INFORMATION 9 1 9 2 9 3 9 4 WARRANTY REPAIR Any device returned requiring warranty service repair or credit must be accompanied with a Return Material Authorization RMA Form It must include return shipping instructions original purchase order number and special marking instruction A description of the trouble observed must be attached to the defective unit This information must be inside the shipping container DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee FL 34972 863 357 0798 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay the shipping costs both directions RETURN FOR CREDIT Material may be returned for credit only with prior approval Material authorized for return is subject to a 20 restocking charge based on the manufacturer s list price Return RMA must be requested no later than 30 days after original shipment CEECO 8 Communication Equipment amp Engineering Company PROPRIETARY ISSUE 4 0 10 0 WARRANTY POLICY 10 1 GENERAL 10 2 CEECO products are gua
2. Nut Driver Flat Blade Screw Driver Security Tool CEECO Part Number 301 064 sold separately CEECO 4 Communication Equipment amp Engineering Company PROPRIETARY ISSUE 4 0 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 5 1 5 2 5 3 5 4 5 5 This unit may be connected to a C O or PBX line and used as a standard ring down unit or it may be used with the optional power supply If so the power supply is intended to run off of an 110v line and comes with a 3 prong grounding plug The 110v outlet must be grounded or a separate ground wire should be run from the individual phone units to a suitable ground Plug the power supply into an 110v outlet and install the power supply in the desired location The selected location must be out of reach for users Grounding and installation must be in accordance with all applicable local and national electrical and building codes Determine the desired mounting locations for the RJ11C modular jack interface units Run the green and red tip and ring wires with the modular jacks interfaces to those locations Mount the jacks interfaces as desired The SSP 350 X 39 is designed to fit into a standard double switch mounting box and is equipped with a modular cord Determine the desired routing path for the modular cords and make the appropriate knock out holes on the mounting boxes Install the mounting boxes as desired Run the modular cords through the knock out holes in the mountin
3. SSP 350 X 39 ISSUE4 0 SERVICE MANUAL FOR MODEL SSP 350 X 39 PRISON VISITATION TELEPHONE WITH FUNCTIONAL MAGNETIC HOOKSWITCH p Communication Equipment 519 West South Park Street Serving the Telephone Industry Since 1930 amp Engineering Company Okeechobee FL 34972 Voice 863 357 0798 Fax 863 357 0006 ISSUE 4 0 IMPORTANT INFORMATION FOR CUSTOMER Please fill in before you continue The following information is necessary when calling CEECO for assistance MODEL NUMBER MODEL SSP 350 X 39 PRISON VISITATION TELEPHONE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for technical support CEECO Communication Equipment amp Engineering Company 519 West South Park Street Okeechobee FL 34972 863 357 0798 Voice 863 357 0006 Fax CEECO 2 Communication Equipment amp Engineering Company PROPRIETARY ISSUE 4 0 TABLE OF CONTENTS SECTION PAGE 1 0 INTRODUCTION eretet verto eue ri EP ee A A d P Ee CY Free rer Ob eee sd PPS citas 4 2 0 GENERAL DESCRIPTION ecce eese eese een eee ness etse esse eese esee sess esee sess eese eesooe 4 30 OPERATION a a 4 40 RECOMMENDED TOOLS AND TEST EQUIPMENT ecce eere neenon 4 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 5 6 0 TESTING GG Gone PEE Seb REPRE dro eERPNOR 6 7 0 SPECIFTCATIONS vecccccis
4. eview the installation steps Make a visual check to ensure that all wires and connectors are as they should be Remember that the phone units which are connected to the same modular jack will allow talk paths to one another A phone connected to one jack interface cannot talk to a phone connected to another jack interface The modular jacks interfaces that are provided must be used as they are modified to work in conjunction with the power supply 6 3 Once it has been determined that the installation and connections are correct and if trouble is still experienced please refer to section 9 2 of this manual SPECIFICATIONS INPUT POWER LOOP CURRENT IMPEDANCE HEARING AID COMPATIBLE ENVIRONMENTAL TELEPHONE COVER DIMENSIONS MOUNTING WEIGHT FCC REGISTRATION C O Line powered or talk battery power supply 23 ma min to 80 ma max 600 ohms Meets EIA standards Temperature 0 C to 50 C Humidity 2095 9096 non condensating Brushed 16 ga Stainless Steel 5 Wide x 5 High x 4 5 Deep Handset On hook Standard double switch electrical box Approximately 3 Ib BW 88T7 13716 TE T CEECO 6 Communication Equipment amp Engineering Company PROPRIETARY 8 0 PARTS LIST QUANTITY PART NUMBER 1 301 591 1 301 004 1 301 009 1 301 018 1 301 005 2 331 006 OPTIONS 1 301 064 1 Standard 1 350 255 1 350 250 ISSUE 4 0 DESCRIPTION Hookswitch Cradle Handset with Armored Cord
5. g boxes Mount the telephone units utilizing the security screws provided to the mounting boxes The security tool which is sold separately must be used for the security screws Plug the modular cords into the modular jacks interfaces The phone units plugged into the same modular jack will allow talk paths to one another If more length is needed for the modular cords a simple in line coupler is recommended A section of modular to modular line cord can then be used to bridge the desired distance The coupler and line cord can be purchased at a typical electronic supply store Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines CEECO 5 Communication Equipment amp Engineering Company PROPRIETARY 6 0 7 0 TESTING ISSUE 4 0 6 1 Lift the handset s of the units that are intended to talk to one another Determine that normal conversation is allowed If so return the handsets to the cradles The phone units are ready for use If this is a single ring down unit connected to a C O or PBX line the call should be automatically placed or connected when the handset is lifted 6 2 If normal conversation does not take place please r
6. ranteed to be free of defects in material and workmanship for a period of 365 days from the date of original purchase CEECO s obligation under this warranty is limited to repair or replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage and cost of repair or consequential damages of any kind which has been caused by neglect abuse acts of God or improper operation of equipment This warranty is limited to the value of material only PRINTED CIRCUIT BOARDS Printed circuit boards should not be field repaired Ifa unit is found to be faulty replace it with another unit and return the faulty unit to CEECO for repair Modifications by any one other than CEECO will void the warranty CEECO 9 Communication Equipment amp Engineering Company PROPRIETARY
7. sscscccssscsccccsssccccecssoccseesssccoudscocsccssscccducsssscsecsedsseuessoncsecssocces 6 8 0 PARTS LIST eeieeseceo vence ocv xa eco o VES ree oe tYrk ee oo Vet rk ee oo VOX Oe pe VETE eo o VERE eoe Ei Ge oo Eon aea e ETE eee ago 7 9 0 REPAIR AND RETURN INFORMATION ee eeeeees eene nne sensa eese ss eeeeaa 8 10 0 WARRANTY POLICY eeces esee e roe ne rape Vr s sia keiro E rt PP eae si EP ee rape ea ek pae Yero 9 CEECO 3 Communication Equipment amp Engineering Company PROPRIETARY 1 0 2 0 3 0 4 0 ISSUE 4 0 INTRODUCTION The practices in this manual provide installation and maintenance information for Model SSP 350 X 39 Stainless Steel Panel Visitation Phone The information in this manual is subject to change without notification For information not included in this manual please call or write CEECO Customer Service 519 West South Park Street 863 357 0798 863 357 0006 FAX GENERAL DESCRIPTION The CEECO Model SSP 350 X 39 is a Ring Down Telephone designed for special purpose applications that require a Vandal Resistant yet attractive telephone The standard SSP 350 X utilizes a constant on power supply whereas this SSP 350 X 39 has a functional hookswitch that allows on and off hook conditions OPERATION Lift the handset and normal conversation will follow Upon completion of call return handset to cradle RECOMMENDED TOOLS AND TEST EQUIPMENT Volt Ohm Meter 1 4