View Manual - Pelican Water
Contents
1. CE QUALITY MANAGEMENT
2. Lamp timer does not read anything Leak detected at filters Possible cause GFCI and or breaker tripped Transient voltage surge suppressor TVSS damaged Power supply damaged Connection between lamp and lamp plug is wet Short circuit in the electrical assembly Threaded pipe fittings are leaking Condensation of moist air on cold chamber slow accumulation O ring damaged deteriorated or incorrectly installed Lamp sleeve assembly not properly installed too tight or not tight enough See Control Panel section on page 15 Equipment downstream of UV system is acting as a breeding ground for pathogens Pathogens are residing in the distribution lines post UV Recontamination from pipe dead ends Unit is unplugged No power at AC power outlet Power cord is damaged Power surge caused damage to electrical assembly O ring damaged deteriorated or incorrectly installed Filter cartridge not centered Possible solution Reset GFCI and or breaker Replace TVSS Replace power supply and use a TVSS Clean and dry lamp pins and lamp plug check unit for leaks or condensation Replace power supply Clean threads reseal with Teflon tape and retighten Control humidity or relocate unit Inspect and replace if deteriorated Tighten assembly hand tight See Control Panel section on page 15 Ensure UV is the last piece of treatment equipment Ensure all distribution lines have been disinfected with chlori
3. Do not touch plug with wet hands WARNING Do not look directly at UV lamp when it is operating The light emitted by the lamp will cause serious eye damage and burn unprotected skin F WARNING Read manual before installing or servicing this system Only authorized personnel possessing M a strong understanding of this system should attempt to replace lamp or service this system NOTE Maximum pressure rating is 125 PSI 8 62 bar TABLE OF CONTENTS e lt ITI JJ lt m Overview 4 Specifications 5 Components 6 Dimensions and layout 8 Z Installation 9 2 Installing the UV system 9 gt Disinfecting the water lines 11 Operation 13 Control panel 13 Troubleshooting 14 Maintenance 15 Sleeve cleaning and lamp replacement 15 Warranty 20 NOILVadadO JONVNALNIVIAI 5 JJ JJ gt 2 2 SPECIFICATIONS e lt u JJ Ti Specifications Maximum operating pressure 125 PSI 862 kPa Maximum ambient air temperature 122 F 50 C Maximum humidity 100 Maximum iron Z G gt m gt O 2 Flow Rates Maximum rated flow at dose of 30 mJ cm 9 GPM 34 LPM Frequency 50 60 Hz Max power consumption 50 Watts NOILVdadO Inlet Outlet 3 4 NPT Rated service life of lamp 1 year Flow rates shown are at 85 UVT JONVNALNIVIAI JJ JJ gt 2 lt COMPONENTS For replacement components please contact your installer listed on the front of this manual o
4. and accepts the plug from this system never use an adapter 8 Visually inspect this system prior to installation If the quartz sleeve or lamp is broken cracked or damaged in any way do not use Contact the supplier for replacement parts Keep all connections dry and off the ground Do not touch plug with wet hands 10 The light emitted by the lamp will cause serious eye damage and burn unprotected skin Do not plug system into an electrical outlet without first properly securing the lamp into the chamber Unplug the system prior to removing the lamp from the chamber 11 If the UV system malfunctions or fails water must be boiled prior to consumption until the UV system is operational and the water lines have been shocked System failure is indicated by the system s audible and visual alarms or the absence of any indicator light 12 Intended for indoor use only System must not be exposed to weather elements In seasonal applications chamber must be drained to prevent freezing 13 Installation of this system must be in accordance with local plumbing and electrical codes as well as any and all applicable regulations and laws 14 SAVE THESE INSTRUCTIONS WARNING To prevent risk of electrical shock connect this system only to a properly grounded grounding type power supply receptacle that is protected by a Ground Fault Circuit Interrupter Pull plug before servicing or replacing lamp Keep all connections dry and off the ground
5. TROJANUVMARX WHOLE HOME UV DISINFECTION SYSTEM and IHS12 D4 2 OWNER S MANUAL PURIFY WATER OF BACTERIA AND VIRUSES Congratulations By purchasing this system you have taken the first step in ensuring safe drinking water for your whole home KEY INFORMATION YOU SHOULD KNOW This product is for indoor use only moe goj S Keep all components clean and dry Date of installation Installer phone Clean the sleeve regularly for optimum performance Serial Found on label on side of Power supply I JA 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 7 519 763 1032 e tf 1 800 265 7246 US and Canada only t 31 73 623 8116 Europe only f 7 519 763 5069 e mail info viqua com www viqua com A TROJAN TECHNOLOGIES COMPANY 520166 R SAFETY INSTRUCTIONS GROUNDING This product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electrical shock This system is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electrocution Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is prop
6. VIQUA product the source dealer as well as a description of the problem you are experiencing A VIQUA technician will help you troubleshoot the problem and isolate the issue In order to establish proof of purchase when making a warranty claim you will need your original invoice or complete and returned your warranty card through the mail or online Specific Warranty Coverage Warranty coverage is specific to the following TroaanUVMax products Ten Year Limited Warranty for TrojanUVMax UV Chamber VIQUA warrants the UV chamber on the TrojanUVMax products to be free from defects in material and workmanship for a period of ten 10 years from the date of purchase During this time VIQUA will repair or replace at its option any defective TrojanUVMax UV chamber Please return the defective part to your dealer who will return it to VIQUA a Trojan Technologies Company We will either make the necessary repairs or if it is determines that a replacement is required will provide a replacement part We will then return the part to the dealer This warranty does not include shipping and handling charges which will be collected from you by the dealer Parts repaired or replaced under this ten 10 year warranty will be covered under warranty to the end of the original ten 10 year warranty period This warranty is also subject to the conditions and limitations outlined under the heading General Conditions and Limitations below Thr
7. and pull to disconnect WARNING To guard against injury basic safety precautions should be observed including the following 1 READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2 DANGER To avoid possible electric shock special care should be taken since water is employed in the use of this system Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections do not attempt repairs yourself refer to an authorized service facility 3 CAUTION Do not operate with broken or faulty parts as this may result in exposure to ultraviolet radiation Contact supplier for replacement parts 4 Do not operate the system if it has a damaged cord or plug or if it is malfunctioning or if it has been dropped or damaged in any manner 5 Always unplug the system shut off water flow and release water pressure before servicing or cleaning Never yank cord to remove from outlet grasp the wall plug and pull to disconnect 6 Do not use the system for other than intended use The use of attachments not recommended or sold by the manufacturer may cause an unsafe condition 7 To prevent risk of electrical shock connect this system only to a properly grounded grounding type power supply receptacle that is protected by a Ground Fault Circuit Interrupter GFCI Inspect performance of GFCI as per manufacturer s suggested maintenance schedule If an extension cord is used ensure it is of a sufficient rating
8. ee Year Limited Warranty for Structural Hardware and Electrical Components VIQUA warrants the structural hardware and electrical components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will return it to VIQUA a Trojan Technologies Company We will either make the necessary repairs or if VIQUA determines that a replacement is required will provide a replacement part We will then return the part to the dealer This warranty does not include shipping and handling charges which will be collected from you by the dealer Parts repaired or replaced under this three 3 year warranty will be covered under warranty to the end of the original three 3 year warranty period This warranty is also subject to the conditions and limitations outlined under the heading General Conditions and Limitations below One Year Limited Warranty for Lamps and Sleeves VIQUA warrants original lamps and sleeves to be free from defects in material and workmanship for a period of one 1 year from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty The warranty period for lamps and sleeves may be verified using date codes in addition to purchase receipts and VIQUA s database of
9. erly grounded Do not modify the plug provided with this system if it will not fit the outlet have a proper outlet installed by a qualified electrician Do not use any type of adapter with this system GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code NFPA 70 and to provide additional protection from the risk of electric shock this system should only be connected to a properly grounded grounding type power supply receptacle that is protected by a Ground Fault Circuit Interrupter GFCI Inspect operation of GFCI as per manufacturers suggested maintenance schedule EXTENSION CORDS If an extension cord is necessary use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from this system Use only extension cords that are intended for outdoor use Use only extension cords having an electrical rating not less than the rating of the system A cord rated for less amperes or watts than this system rating may overheat Exercise caution when arranging the cord so that it will not be tripped over or pulled Do not use damaged extension cords Examine extension cord before using and replace if damaged Do not abuse extension cord Keep extension cord away from heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug
10. into chamber Caution Over tightening will break the sleeve Align connections by rotating ring clamp to push lamp plug onto end of lamp Attach ground green yellow and strain relief red wires from the lamp plug to the ground lug on the chamber Secure both wires with locking screw provided Ground and strain relief wires Push safety cap into place Let water flow to one faucet or other water outlet then close the outlet and check for leaks Proceed to Disinfecting The Water Lines MaAIAYSAO NOILVdadO JONVNALNIVIAI JJ JJ gt Z o NOILLVTIVLSNI DISINFECTINGTHE WATER LINES UV systems disinfect the water using ultraviolet light treating the water as it passes through the system When there is a risk that water downstream of the UV system has been contaminated it is critical that these water lines be chemically disinfected Disinfection of the water lines is therefore required after initial system installation and following any period of time during which the system is inoperative whether due to an alarm condition a power failure or for any other reason Make sure the UV system is on during the entire disinfecting process INE UAR E TANO 1 Make sure power supply and lamp are plugged in for entire disinfection process Caution The sump pumps will be full of water and will be heavy NOILLVTIVLSNI I _ XVANANNVen Melia 4 ET 0 Relieve pressure in
11. ne see Disinfecting the Water Lines section Remove any pipe dead ends and flush with chlorine see Disinfecting the Water Lines section Plug unit into AC power outlet Replace fuse or reset breaker Replace power cord Replace power supply and use a surge protector TVSS Remove the sump wipe the o ring and threads clean ensure the o ring is fitted properly then reinstall Remove sump check for cartridge damage re assemble ensuring cartridge is centered 14 e m gt 2 e SLEEVE CLEANING amp LAMP REPLACEMENT Sleeve Cleaning Minerals in the water slowly form a coating on the sleeve This coating must be removed because it reduces the amount of UV light reaching the water thereby reducing purification performance Please clean the sleeve regulary 3 4 times per year or more often depending on water quality When only cleaning is required follow instructions and re install the current lamp Lamp Replacement The amount of UV light created by the lamp decreases over time requiring that the lamp be replaced every 12 months NOTE The UV system is designed to operate continuously and should not be shut off for short periods of time such as over a period of less than three weeks The system will automatically notify you after 12 months to replace the lamp Follow these instructions Equipment required KANN Gloves Scale remover such as Cloth must be soft lint free and CLR or Lime Awa
12. r contact VIQUA directly for a referral 1 800 265 7246 North America 519 763 1032 or info viqua com o lt u JJ lt m Components Part Part Number 3 Reference card 603069 TROJANUV NOILVTIVLSNI 4 Power cord 602636 120V 602637 230V 6 Lamp cord TROJAN U VMAX NOILVadadO JONVNALNIVIAI 5 JJ JJ gt 2 2 COMPONENTS Components o lt u JJ Ti Part Part Number O ring ze Sleeve includes O rings 602732 Sediment filter CMB 510 HF 10 HIGH 5 micron Bracket z Drain Plug Z NOILVTIVLSNI NOILVdsdO JONVNALNIVIAI 5 JJ JJ gt 2 2 DIMENSIONS AND LAYOUT e lt m JJ m HOT WATER PIPE COLD WATER PIPE a Main Water Shut Off 16 Clearance for lamp removal Optional By Pass Assembly E o S S L Optional 3 Water S Softener MIN 4 from bottom of unit for clearance for filter changes Main water shut off valve Shut off valve Allows for ease of maintenance of whole home UV disinfection system Bypass shut off valve Bypass line and valve are optional Intended to provide emergency water supply in the event that the UV system is unavailable Shut off valve Allows for ease of maintenance of whole home UV disinfection system Whole Home System Provides filtration and disinfection of the water Power supply Powers and controls the UV lamp and other devices Provides h
13. ranties cover damage caused by improper use or maintenance accidents acts of God or minor scratches or imperfections that do not materially impair the operation of the product The warranties also do not cover products that are not installed as outlined in the applicable Owner s Manual The limited warranties described above are the only warranties applicable to the TrojanUVMax products listed These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products whether the claim is based on contract tort including negligence strict liability or otherwise These warranties are in lieu of all other warranties whether written oral implied or statutory Without limitation no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products VIQUA a Trojan Technologies Company does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products VIQUA shall not in any event be liable for special incidental indirect or consequential damages VIQUA s liability shall in all instances be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period JJ JJ gt 2 gt 20 TROJANUVMAX 520166 R Printed in Canada Copyright 2010 VIQUA a Trojan Technologies Company Guelph Ontario Canada
14. registered owners VIOQUA will advise you whether the defective item needs to be returned to a VIQUA dealer for failure analysis Replacement lamps and sleeves provided under warranty will be sent to your TrojanUVMax dealer This warranty on lamps and sleeves does not include shipping and handling charges which will be collected from you by the dealer Parts replaced under this one 1 year warranty will be covered under warranty to the end of the original one 1 year warranty period This warranty is also subject to the conditions and limitations outlined under the heading General Conditions and Limitations below Warranty for Replacement Lamps and Parts VIQUA warrants replacement lamps purchased for annual routine maintenance and other parts purchased to repair product components that are no longer covered by the original warranty to be free from defects in material and workmanship for a period of three 3 months from the date of purchase During this time we will repair or replace at its option a defective replacement lamp or part free of charge except for shipping and handling charges The warranty period on replacement lamps and parts will be verified using date codes and or purchase receipts VIQUA will advise you whether the defective item needs to be returned to your dealer for failure analysis Replacement lamps and parts provided under warranty will be sent to your dealer General Conditions and Limitations None of the above war
15. s After that the button will silence for only 24 hours When the alarm is due to any other issue the mute button will silence the audible alarm for 24 hours Indicator lights Indicator lights only indicate a problem with the component when flashing red The table below is a list of possible causes and solutions Before replacing parts please contact VIQUA Technical Assistance for any new troubleshooting techniques 1 800 265 5774 13 Option not available on this system Lamp operating normally Power supply operating normally Option not available on this system Warning lamp will require replacement shortly Air temperature around system is too warm Flashing red Option not available on this system Lamp disconnected unplug system reconnect lamp and plug in system again Lamp failure replace lamp Power supply failure replace power supply Solid red Option not available on this system Lamp inactive due to power supply failure Power supply inactive due to lamp failure e m gt 2 e TROUBLESHOOTING The table below is a list of possible causes and solutions Before replacing parts please contact VIQUA Technical Assistance for any other troubleshooting techniques 1 800 265 7246 No power GFCI or breaker repeatedly trips Leak at inlet or outlet Leak detected from area of UV chamber Alarm System is operating but water tests reveal bacterial contamination
16. the filter 1 2 cups 5 25 bleach JONVNALNIVIAI Nuva 2 za lt gt gt x gt JJ JJ gt 2 2 11 Go to a water outlet and allow the cold water to flow until you can smell bleach then stop the flow Allow hot water if present to flow until you can smell bleach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside taps and other water outlets Note You will likely run out of bleach if you cannot smell bleach at a given outlet turn off the main water supply depressurize and add more bleach to the filter housing gt do I fa Let the bleach sit in the water lines for at least four hours XVNANNV Tan vimax j 2 Z x lt gt gt x Hold down PR button to purge air Flush all water outlets until bleach can no longer be smelled at least 5 minutes AAYE LAR E TANO LO At s E fe 0 JONVNALNIVIAI S JJ JJ gt 2 gt NOILVTIVLSNI CONTROL PANEL Buttons and Display TROJAN MAX Lamp timer Counts down from 365 days to show time for annual lamp replacement display Lamp timer After installing a new lamp press and hold for five seconds to reset Lamp timer to reset 365 Mute Press to silence audible alarm When the alarm is due to the lamp s age the mute button will silence the audible alarm for 7 days this may be repeated up to a maximum of 4 time
17. uman interface displaying information and allowing control inputs such as muting the audible alarm Power source Provides power to the power supply For safety reasons the outlet must be protected by a Ground Fault Circuit Interrupter GFCI NOTE to protect the power supply a UL1449 certified or equivalent transient voltage surge suppressor is required o Go eo INSTALLING THE UV SYSTEM Determine appropriate indoor location of Outlet must be the power supply and chamber referring protected by a to Dimensions and Layout drawing uae Ground Fault Ensure adequate clearance above Circuit Interrupter chamber to allow for removal of the GFCI lamp and sleeve Make sure to turn off the main water supply o w gt L amp r TE BATI T u 1 Mount the system to the wall with appropriate lag bolts through the two mounting holes located on the metal bracket The supplied lag bolts are Suitable for attachment to wood Attachments to other materials will require purchasing of alternative hardware NOILLVTIVLSNI Make all necessary plumbing connections referring to Dimensions and Layout drawing Install sleeve bolt with 2 o rings Slide power Screw lamp into sleeve hand tight supply onto mounting Caution Over tightening will break the bracket l G sleeve TROJAN MA Slide Reference TROIANUY card behind power supply Insert Lamp sleeve assembly and screw
18. was replaced Press and hold Lamp timer reset button for 5 seconds Display should read 365 Check for leaks JJ JJ gt Z o VANE At ETAO NOILLVTIVLSNI NOILVadadO JONVNALNIVIA CARTRIDGE REPLACEMENT It is recommended to change the filter cartridges regularly approximately 3 4 times per year depending on water quality and usage A gradual drop in water pressure after the filtration device is an indication that the pre filter cartridges are nearing the end of their useful life Discard the used cartridges and clean the sump housing Bg XVAANNVI Install new cartridges Relieve pressure in the filter lt mr m lt gt lt O m XVAN Press down the pressure relief button on top of the sump until air that might be present is purged from filter WARRANTY Our Commitment To maximize the superior quality of disinfection each TrojanUVMax product must be properly installed and maintained If you experience difficulty with your product our Technical Support Centre is available to help you During the applicable warranty period noted below we will provide warranty coverage described below for your product How to Get Help To obtain help under this warranty contact the VIQUA Technical Support Center at 1 800 265 7246 or by email at info viqua com Please have available the model number the date of purchase the name of the dealer from whom you purchased your
19. y chemical free No clean wipes t m Each component of our UV products has been g e n u ne designed and developed through extensive research and development to be part of an overall system that operates safely and effectively over its entire lifetime Using genuine parts for our UV systems not only ensures the quality of the disinfection but also ensures maintenance of your system warranty 15 MaAIAYSAO NOILVHYJdO NOILVTIVLSNI JONVNALNIVIA JJ JJ gt Z gt Relieve pressure in the filter 1 Squeeze tabs Strain relief wires should remain connected sleeve bolt to remove lamp sleeve assembly Skip to step 13 Note Sleeve must be replaced if it cannot be completely cleaned or if it appears scratched or cracked For lamp or sleeve replacement Clean sleeve and follow steps 9 12 AAE At ETANO NOLL TIVLSNI gt JJ JJ gt gt NOILV4JdO J NVNJLNIVIN Screw lamp into sleeve hand tight Caution Over tightening will break the sleeve MaAIAYSAO NOILVTIVLSNI Make sure lamp sleeve assembly is centered Caution Over tightening will break the sleeve NOILVadadO Remove o rings and sleeve bolt from sleeve Reinstall sleeve bolt with 2 new o rings JONVNALNIVIA JJ JJ gt Z o 17 Align connections by rotating ring clamp to push lamp plug onto end of lamp Push safety cap into place If lamp