Home

Installation

image

Contents

1. 215 158FW Rev K ECN 12 05 003C 2012 Bradley Installation S19 220FW Wall Mounted Eye Face Wash w Plastic Bowl Douche oculaire faciale murale avec cuvette en plastique Lavador de ojos rostro para montaje en pared con recipiente de pl stico 19 220T Wall Mounted Eye Face Wash w Stainless Steel Bowl Douche oculaire faciale murale avec cuvette en acier inox Lavador de ojos rostro para montaje en pared con recipiente de acero inoxidable Table of Contents Pre Installation Information 2 Installation Instructions 3 Components and Parts List 4 5 Table des mati res Avant l installation 6 Instructions d installation 7 Composantes et Liste des pi ces 8 9 Contenido Informaci n previa a la instalaci n 10 Instrucciones de instalaci n 11 Componentes y Lista de piezas 12 13 Bradley e P O Box 309 Menomonee Falls WI USA 53052 0309 PHONE 800 BRADLEY 800 272 3539 FAX 262 251 5817 bradleycorp com S19 220FW S19 220T Installation IMPORTANT Read this installation manual completely to ensure proper installation then file it with the owner or maintenance d
2. Una vez que termine la instalaci n entregue este manual al propietario o al Departamento de Mantenimiento Es responsabilidad de quien instale el equipo cumplir con los c digos para desag e y otra c digos y ordenanzas locales Separar todas las piezas del material de embalaje y asegurarse que todas las piezas est n inclu das antes de desechar cualquier material de embalaje Si faltase alguna pieza no intentar instalar la unidad combinada Bradley hasta obtener las piezas faltantes Aclarar el conducto del suministro de agua antes y despu s de la instalaci n Verificar que no haya fugas y que el flujo de agua sea adecuado El suministro principal de agua a la unidad debe estar siempre en posici n ON abierto Se deben tomar medidas a fin de evitar el corte no autorizado del suministro La norma ANSI Z358 1 exige un suministro ininterrumpido de l quido de limpieza Los equipos de emergencia con tuber as de Bradley requieren una presi n de flujo m nima de 0 21 MPa 30 PSI El l quido de limpieza debe estar tibio en conformidad con la norma ANSI Z358 1 Este equipo se debe inspeccionar probar y anotar semanalmente para mantener un funcionamiento adecuado Se debe revisar este equipo anualmente para asegurarse de que cumpla con la norma ANSI Z358 1 Los trabajadores que puedan tener contacto con materiales potencialmente peligrosos deben recibir capacitaci n sobre la ubicaci n y operaci n adecuada de los equipos de emergencia e
3. e 191mm 9mm 5 4 133mm F Y S19 220T Murale A i 4 114mm y 8 A 210mm 13 346mm 10 273mm e 157 A Sr adn 36 914mm ps tia du D recommand e al 57mm 7 0 8 206mm a UY I 9mmmm Le 5 5 133mm 29 749mm hauteur du sol recommand e Bradley 215 158FW Rev K ECN 12 05 003C 10 18 2012 S19 220FW S19 220T Installation IMPORTANTE Lea en su totalidad este manual de instalaci n para garantizar una instalaci n adecuada Una vez que termine la instalaci n entregue este manual al propietario o al Departamento de Mantenimiento Es responsabilidad de quien instale el equipo cumplir con los c digos para desag e y otra c digos y ordenanzas locales Separar todas las piezas del material de embalaje y asegurarse que todas las piezas est n inclu das antes de desechar cualquier material de embalaje Si faltase alguna pieza no intentar instalar la unidad combinada Bradley hasta obtener las piezas faltantes Aclarar el conducto del suministro de agua antes y despu s de la instalaci n Verificar que no haya fugas y que el flujo de agua sea adecuado El suministro principal de agua a la unidad debe estar siempre en posici n ON abier
4. 5 158FW Rev K ECN 12 05 003C Installation S19 220FW S19 220T Installation NOTICE Avoid cleaners containing organic solvents alcohols and hydrocarbons Rinse with water after cleaning Supplies Required e 3 wall fasteners and bolts e Pipe sealant e Piping to Y IPS water supply inlet on unit e Piping to 1 IPS drain outlet e Sign mounting hardware Step 1 Install inlet drain fitting The top of the eyewash heads should be 33 45 838mm 1143mm from the floor 1 Position the inlet drain fitting over the 1 drain outlet pipe from wall 2 Using the inlet drain fitting as a template mark the bolt hole locations on the wall OR install three suitable fasteners supplied by installer for bolts in the wall at the marked hole locations see Figure 1 3 Bolt the inlet drain fitting to the wall or wall fasteners using bolts supplied by installer Step 2 Assemble eye face wash 1 Assemble eyewash components as shown in Figure 2a on page 4 or Figure 2b on page 5 e Apply pipe sealant supplied by installer to all male threaded pipe joints e Use the rubber grip pad provided or a strap wrench around pipes when tightening to prevent marring the Bradtect protective safety yellow coating Place the grip pad on the pipe then put the wrench over the grip pad and turn the pipe with the wrench Step 3 Connect water supply 1 Connect the water supply piping supplied by installer to t
5. IPS de suministro de agua a la unidad e Tuber a para la salida de 1 IPS para el lavador de ojos e Torniller a para montar el aviso de seguridad Paso 1 Instale el accesorio de entrada del drenado Y La parte superior de los rociadores deben quedar a 1 metro 42 del piso 1 Coloque el accesorio de entrada del drenado sobre el tubo de salida de drenado de 1 IPS saliendo de la pared 2 Usando el accesorio de entrada del drenado como plantilla marque los orificios para ubicaci n de los pernos en la pared O instale tres soportes de pared adecuados proporcionados por el instalador para pernos de en la pared en los lugares marcados para los orificios Figura 1 3 Fije el accesorio de entrada de drenado a la pared o f jelo en la pared usando los soportes de pared y pernos de proporcionados por el instalador Paso 2 Armado de los componentes del lavador de ojos 1 Arme los componentes restantes del lavador de ojos como se indica en la Figura 2a p gina 12 o Figura 2b p gina 13 e Aplique sellador de tubos proporcionado por el instalador a todas las uniones de los tubos macho roscados e Utilizar un taco de caucho o llave de correa alrededor de los tubos al apretar para evitar ara azos Colocar el taco de goma en el tubo y a continuaci n colocar la llave de correa sobre el taco Con el taco en su lugar girar el tubo con la llave de correa Paso 3 Conecte el suministro de agua 1 Conecte l
6. a tuber a de suministro de agua a la entrada de Ye IPS en el lavador de ojos la tuber a es proporcionada por el instalador 2 Conecte la pieza inferior a la salida de drenado de 1 IPS en el lavador de ojos 3 Fije el aviso de seguridad a la pared usando torniller a adecuada proporcionada por el instalador 4 Abra las l neas del suministro de agua Revise 13 337mm 10 254mm 36 914mm 15 394mm A y 102mm 8 206mm i de altura desde el piso recomendada y y ag 57mm TR D 191mm y 9mm ly 54 _ 133mm 19 220T Pared FT 2912 749mm de altura desde el piso recomendada 13 al a 4 114mm 84 210mm V S 346mm Le TO 10 273mm 157 403mm 102mm 36 914mm P de altura X desde el piso 8 la recomendada 206mm UY INF 7 oui M oe ii mm orram de altura 7 Oe desde el piso 191mm 9mmmm 4 5 gt recomendada 133mm 2 i Bradley 215 158FW Rev K ECN 12 05 003C 10 18 2012 11
7. epartment Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material If any parts are missing do not begin installation until you obtain the missing parts Flush the water supply lines before beginning installation and after installation is complete Test the unit for leaks and adequate water flow Main water supply to the eyewash should be ON at all times Provisions shall be made to prevent unauthorized shutoff The ANSI Z358 1 standard requires an uninterrupted supply of flushing fluid Bradley plumbed emergency fixtures require a minimum of 30 PSI 0 21 MPa flowing pressure Flushing fluid should be tepid per ANSI Z358 1 The inspection and testing results of this equipment should be recorded weekly to verify proper operation This equipment should be inspected annually to ensure compliance with ANSI Z358 1 Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358 1 For questions regarding the operation or installation of this product visit www bradleycorp com or call 800 BRADLEY 800 272 3539 Product warranties and service parts information may also be found under Products on our web site at bradleycorp com 10 18 2012 Bradley 21
8. he Y IPS inlet on the eye face wash 2 Connect the tailpiece to the 1 IPS drain outlet on the eyewash 3 Mount the safety sign to the wall using sign S19 220FW Wall A aa 42 114mm y 13 337mm 10 254mm 15 394mm A mn a i 102mm 36 914mm 7 Suggested Height to 8 D Floor 206mm 1 y j A 24 R 29 57mm 749mm 7 DY 5 Suggested 191mm 9mm 814 210mm Ly Height to lt Floor 133mm S19 220T 4 114mm 84 210mm mal Wall gt 10 273mm He 157 403mm wit gt q 102mm 6 914mm Suggested Height to 3 8v Floor 206mm 7 Y y sl Ur 29 gt y mounting hardware supplied by installer Open the water supply lines Test for leaks and adequate water flow 57mm 7 191mm 9mmmm a 5 133mm 749mm Suggested Height to Floor Bradley 215 158FW Rev K ECN 12 05 003C 10 18 2012 S19 220FW S19 220T Installation IMPORTANT Lea en su totalidad este manual de instalaci n para garantizar una instalaci n adecuada
9. n conformidad con la norma ANSI Z358 1 Para consultas sobre la operaci n o instalaci n de este producto visite www bradleycorp com o llame al 800 BRADLEY 800 272 3539 Las garant as del producto se pueden encontrar en Informaci n del producto o en nuestro sitio Web www bradleycorp com 10 18 2012 Bradley 215 158FW Rev K ECN 12 05 003C Installation S19 220FW S19 220T Installation AVIS viter les nettoyants qui contiennent des solvants organiques de l alcool et de l hydrocarbure Rincer avec de l eau apr s le nettoyage Equipements n cessaires e 3 attaches murales et boulons de po e Scellant pour tuyaux e Tuyauterie d entr e de Y IPS pour l approvisionnement en eau de l unit e Tuyauterie de sortie de 1 IPS e Quincaillerie pour l installation de l enseigne tape 1 Installer le raccordement d entr e du drain Ca 1 Positionner le raccordement d entr e du drain sur le tuyau de 1 po du drain de sortie du mur Le dessus des rogateurs de la douche oculaire faciale doit tre situ 33 45 po 838mm 1143mm du sol 2 En utilisant le raccordement d entr e du drain comme gabarit marquer l emplacement des trous sur le mur OU installer trois attaches fournies par l installateur pour les boulons po dans le mur l emplacement des marques de trous Figure 1 3 Boulonner au mur le raccordement d entr e du drain ou utiliser les attaches murales avec des bo
10. to Se deben tomar medidas a fin de evitar el corte no autorizado del suministro La norma ANSI Z358 1 exige un suministro ininterrumpido de l quido de limpieza Los equipos de emergencia con tuber as de Bradley requieren una presi n de flujo m nima de 0 21 MPa 30 PSI El l quido de limpieza debe estar tibio en conformidad con la norma ANSI Z358 1 Este equipo se debe inspeccionar probar y anotar semanalmente para mantener un funcionamiento adecuado Se debe revisar este equipo anualmente para asegurarse de que cumpla con la norma ANSI Z358 1 Los trabajadores que puedan tener contacto con materiales potencialmente peligrosos deben recibir capacitaci n sobre la ubicaci n y operaci n adecuada de los equipos de emergencia en conformidad con la norma ANSI Z358 1 Para consultas sobre la operaci n o instalaci n de este producto visite www bradleycorp com o llame al 800 BRADLEY 800 272 3539 Las garant as del producto se pueden encontrar en Informaci n del producto o en nuestro sitio Web www bradleycorp com 10 10 18 2012 Bradley 215 158FW Rev K ECN 12 05 003C Installation S19 220FW S19 220T Installation pared gt 19 220FW AVISO Evite los limpiadores que contengan A J solventes org nicos alcoholes e a vie a hidrocarburos Enjuague con agua despu s gu de limpiar 210mm Materiales necesarios e 3 soportes de pared y pernos de e Sellador de tubos e Tuber a para la entrada de Y
11. ulons po fournis par l installateur tape 2 Assemblage des composantes de la douche oculaire 1 Assembler les composantes restantes de la douche oculaire tel qu indiqu la Figure 2a en page 8 ou Figure 2b en page 9 e Appliquer le scellant pour tuyaux fourni par l installateur tous les joints de tuyaux filet s m les e Utiliser un isolant en caoutchouc ou une cl sangle pour ne pas griffer les tuyaux Placer Pisolant sur le tuyau puis la cl sur l isolant et faire tourner le tuyau avec la cl tape 3 Raccorder l approvisionnement en eau 1 Raccorder la tuyauterie d approvisionnement en eau l entr e Y NPT sur la douche oculaire tuyauterie fournie par l installateur 2 Raccorder le raccord droit de vidange au drain de sortie de 172 NPT sur la douche oculaire 3 Installer l enseigne de s curit au mur l aide de la quincaillerie d installation fournie par l installateur 4 Ouvrir les lignes d approvisionnement en eau V rifier s il y a des fuites et si le d bit d eau est ad quat S19 220FW Murale mm EN 42 114mm y 10 254mm e 15 394mm 8u 210mm 4 A 102mm gt 36 914mm J hauteur du sol 81 gt recommand e 206mm Y y A 241 1 29 749mm 2 57mm hauteur du sol 7 y recommand

Download Pdf Manuals

image

Related Search

Installation installation installation assistant installation directory installation folder installation art installation media installation wizard installation file installation manager installation assistant windows 11 installation status report installation made easy installation floater installation of mini split air conditioner installation definition installation status installation guide installation synonym installation instructions installation manual installation has failed discord installation failed installation wizard 2 installation whatsapp installation and commissioning

Related Contents

Sony MDR-KX 70  User Manual User Manual  Guida per l`utente Istruzioni per l`uso  Manual - Penguin Computing  O2 Innovations O2-B User's Manual  US Water 9000/9100/9500 Twin  Installation Manual ProfiTap Industrial  OTS-600 Series Optical Sources, Meters, Testers and  光触媒(高機能コーティング)材料用 温風低圧塗装システム  

Copyright © All rights reserved.
Failed to retrieve file