Home

Installation Manual

image

Contents

1. ART 02478 6 The cutout opening must be square and perpendicular to the enclosure shelf to maintain door alignment 7 Using the following chart decide which vents and rough opening RO sizes to use Certified Vent P N RO Height Upper Roof Exhaust Cap 622293 N A 625240 N A Upper Roof Exhaust Vent 616319 24 in 625161 24 in Upper Plastic Exhaust amp Lower Intake 628073 13 3 4 in Install the Lower Intake Vent RO Width N A N A 5 1 4 in 5 1 4 in 29 5 16 in Install the lower intake vent See Art02479 The lower intake vent is also the service access opening for the NOTICE components on the rear of the refrigerator Make sure the bottom of the opening of the lower intake Awarninc vent is even with or immediately below the floor level This allows any leaking propane gas to escape to the outside and not to collect at floor level Make sure the bottom of the opening of the lower intake vent 9 is even with or immediately below the floor level Make sure that the opening for the lower intake vent is between 1 2 inch and 1 inch 182 from the burner side of the refrigerator enclosure Installation Manual 6 Install an Upper Roof Exhaust Vent 1 Install the upper roof exhaust vent Acaution Make sure that no sawdust insulation or other
2. Fermer les portes 2 Mettre le r frig rateur compl tement dans l enceinte Pousser en dessous du centre du r frig rateur ART 02490 13 Manuel d installation Tirer en utilisant un outil en fil m tallique accroch dans les trous de montage 121 du chassis du r frig rateur voir Art02490 3 Positionner le r frig rateur Aavertissement S assurer que le joint de combustion n est pas rompu qu il entoure compl tement les brides de montage du r frig rateur et qu il s pare ces brides de la paroi de l enceinte Si le joint est interrompu des gaz d chappement peuvent s infiltrer dans l habitacle du v hicule L inhalation de gaz d chappement peut causer des vertiges des naus es ou dans les cas extr mes la mort AVIS Faire attention lors du positionnement du r frig rateur Il n est AVIS pas n cessaire de retirer l emballage protecteur des portes des mod les portes m talliques pour installer ou utiliser le r frig rateur Veiller ce que le capuchon du conduit de fum e ne soit pas enfonc contre le haut du tube de ce conduit Faire entrer compl tement le r frig rateur dans l enceinte 4 Poser les vis de montage et la garniture voir Art01814 Ins rer les quatre vis 41 travers les brides de montage sup
3. Veiller ce que l ouverture de la prise d air inf rieure se trouve de 1 2 po 1 po 182 du c t br leur de l enceinte du r frig rateur i ART 02479 Manuel d installation 6 Installation d une bouche d chappement sup rieure de toit 1 Installer la bouche d chappement sup rieure du toit A attention S assurer de l absence de sciure de mat riau d isolation ou d autres d bris de construction sur le r frig rateur ou dans l enceinte Les d bris peuvent poser un danger de combustion et emp cher le _ fonctionnement correct du r frig rateur a AA Serrer les vis de la came d chappement sup rieur du toit 10 Ib po max S assurer AVIS galement que l coulement d air autour de la came d chappement sup rieure du toit n est pas partiellement ou totalement restreint par d autres articles mont s sur le toit tels que porte bagages climatiseur panneau solaire etc 2 Aligner la bouche d chappement sup rieure du toit au dessus de la prise d air inf rieure 3 D terminer le type de l enceinte dans un v hicule utilisant une bouche d chappement sup rieure de toit voir Art02480 Si la distance depuis la face de l enceinte au bord int rieur de l ouverture 169 de la bouche ART 02480 d chappement du toit est sup rieure a 17 1 2 po installer la bouche d chapp
4. Poser un d flecteur sup rieur en bois ou en t le d aluminium ou d acier galvanis 13 entre le haut du r frig rateur et le haut de la bouche d chappement sup rieure 24 Veiller a ce qu il y ait un d gagement de moins de 1 4 po 15 entre le d flecteur sup rieur et le haut du r frig rateur et que le d flecteur chevauche le r frig rateur de 1 po ou moins S assurer que le d flecteur se trouve contre la paroi du v hicule en haut de la bouche d chappement sup rieure et a moins de 1 4 po au dessus de l ouverture de la bouche d chappement sup rieure Installer un d flecteur de condenseur en t le cintr e d aluminium ou d acier galvanis 26 Veiller ce que la courbure du d flecteur de condenseur fasse toute la largeur de l int rieur de l enceinte EA S assurer que la courbure du d flecteur de condenseur affleure le bord inf rieur du cadre de la porte de la bouche d chappement ART 02488 sup rieure de paroi lat rale S assurer que le bord sup rieur du d flecteur de condenseur se trouve 1 4 po ou moins 15 du coin inf rieur arri re du condenseur Si la profondeur de l enceinte est sup rieure ou gale 26 po voir Art02489 Poser un d flecteur sup rieur en bois ou en t le d aluminium ou d acier galvanis
5. 15 Manuel d installation Raccordement de chauffage basse temp rature ambiante Connectez les fils de chauffage ambiant faible l alimentation en courant continu de 12 volts Le fil noir du chauffage ambiant faible se connecte 12V et le fil marron se connecte la terre de 12V AVIS Ce kit alimente le chauffage en tension c c chaque fois que la temp rature ambiante est suffisamment basse Un entreposage prolong par temps froid d charge les batteries du v hicule Pour viter la d charge des batteries d brancher le fusible 3 A du chauffage a basse temp rature ambiante Branchement des l ments du gaz propane Ce r frig rateur fonctionne au gaz propane a une pression de 11 po de colonne d eau Les commandes fonctionnent sur un courant de 12 volts c c 10 5 volts min a 15 4 volts max Le fonctionnement en dehors de ces limites peut endommager les composants du circuit lectrique du r frig rateur et annulera la garantie Raccordement du syst me d alimentation en gaz propane A avertissemenT Faire preuve de grande prudence lors de l intervention sur le syst me de gaz propane ou du travail proximit Ne pas fumer ni utiliser une flamme nue proximit du syst me de gaz propane Ne pas se servir d une flamme nue pour rechercher les fuites Ne pas brancher le r frig rateur la bouteille de gaz propane en l absence d un manod tendeur entre les deux Pour viter une f
6. If an external power source is utilized the appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes the National Electrical code and ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 Parts 1 and 2 All propane gas supply piping and fittings must obey local state and national codes about type and size These components must also obey the current NFPA 1192 section 2 4 and in Canada with the current CAN 1 6 10 Standard Ventilation Requirements Awarninc The completed installation must Make sure there is sufficient intake of fresh air for combustion Make sure the living space is completely isolated from the combustion system of the refrigerator Make sure there is complete and unrestricted ventilation of the flue exhaust which in gas mode can produce carbon monoxide The breathing of carbon monoxide fumes can cause dizziness nausea or in extreme cases death Make sure the refrigerator is completely isolated from its heat generating components through the correct use of baffles and panel construction Certified installation needs one lower intake vent and one upper exhaust vent Install the vents exactly as written in this manual Any other installation method voids both the certification and the factory warranty of the refrigerator The bottom of the opening for the lower intake vent which is also the service access door must be even with or i
7. 13 entre le haut du r frig rateur et le haut de la bouche d chappement sup rieure 24 Veiller a ce qu il y ait un d gagement de moins de 1 4 po 15 entre le d flecteur sup rieur et le haut du r frig rateur et que le d flecteur chevauche le r frig rateur de 1 po ou moins S assurer que le d flecteur se trouve contre la paroi du v hicule en haut de la bouche d chappement sup rieure et a moins de 1 4 po 15 au dessus de l ouverture de la bouche d chappement sup rieure Installer un d flecteur en forme de bo te pleine 21 entre la prise d air inf rieure et la bouche d chappement sup rieure Fabriquer le d flecteur en forme de bo te pleine en bois ou en t le d aluminium ou d acier galvanis S assurer que le bas du d flecteur en forme de bo te pleine se trouve entre 21 po et 21 1 2 po au dessus du bas de l enceinte 17 7 1 4 po 7 3 4 po au dessus du haut de l ouverture de la prise d air inf rieure REF 18 ART 02489 Veiller ce que l arri re du d flecteur en forme de bo te pleine soit perpendiculaire au bas de l enceinte 11 Manuel d installation S assurer que la partie sup rieure horizontale du d flecteur en forme de bo te pleine affleure le bord inf rieur de la bouche d chappement sup rieure 24 S assurer que le bord sup
8. NORCOLD Inc Telephone 800 543 1219 P O Box 4248 Fax 734 769 2332 Sidney OH 45365 4248 Web Site www norcold com Part No 636901A 08 22 2014 Table of Contents SE AAA EEE CE lhi oa alal iena 2 Safety INStrUctions sari aaa 3 Certification and Code Requirements nai ini iaia 3 Ventilation Requirements ivi I I ivi ai 4 Rey Refrigerator DIMENSIONS ai a ia 5 Assemble the Enclosure forthe Refrigerator i o e iii 5 Install the Lower Intake Vent nirin a praline eat 6 Installithe Upper Root Exhaust Vent sacked iia dite iene ele a e hi eee iii 7 Install the Baffles foran Upper Roof Exhaust Vent ia 7 Verticalienclosures iii hai tan eed ante aaa asia keto 7 Offset vertical enclos ures Arrea nina nai ei AARON RARA TARANTO doused i recisi io 9 InstallianUpper Side Wall Exhaust Vent ian 10 Installithe Baffles for an Upper Side Wall Exhaust Vent iii 11 InstalitanzAirBerlector oplional gt ae i ee an sent ne ie 12 Install Decorative Door Panels non metal door MOdEIS i 12 Install th Refmgeratori tirar ai i ini ia ii 13 Connectthe Electrical Components ii N N a E oi cau eee 14 Connect the 120 Volts AC SuppIy ei RIRE ia iaia dina 15 Connect the 12 volts DC SUpplY 105 iaia iii 15 Connect the Low Ambient Heater optional sanitaire dan ta dre Lana nea ede ee ates ee eee 15 Connect the Propane Gas Components Luuaiai ai i iaia 16 Connectithe propane gas suppl
9. aide de deux cl s serrer l crou de compression de 1 1 2 tour 2 tours Ouvrir le robinet d arr t d eau du v hicule Chercher les fuites au niveau des raccords 17 Manuel d installation Allumage et mise en marche Avant l allumage ou la mise en route du r frig rateur S assurer que le d bit d air dans la prise d air inf rieure par le serpentin et le condenseur et par le dispositif d vacuation sup rieur ne rencontre pas d obstacles et reste constant S assurer qu il ne se trouve aucun mat riau combustible dans le r frig rateur ni autour de l appareil Allumage et mise en route Si le gaz ne s allume pas dans les 30 secondes le robinet de gaz du r frig rateur se ferme automatiquement AUE l allumeur ne fait plus d tincelle une alarme sonore retentit et les codes d anomalie no FL clignotent sur l cran cristaux liquides 280 Pour r initialiser les commandes appuyer sur le bouton MARCHE ARRET DE L ALIMENTATION 30 et le maintenir enfonc pendant 1 seconde pour teindre le r frig rateur puis appuyer de nouveau dessus pour red marrer le r frig rateur voir Art02492 Si l allumage ne se produit pas apr s plusieurs tentatives se reporter la section Codes de d faillance de ce manuel Modes de fonctionnement 1 Appuyer sur le bouton MARCHE ARRET DE L ALIMENTATION 30 et le rel cher 2 S lectionner le mode de fonctionnement ppuyer sur le bouton MODE 31 e
10. flecteur d angle int rieur 173 entre le bord ext rieur de l ouverture de la bouche d chappement sup rieure et le d flecteur en forme de bo te pleine S assurer que le d flecteur d angle int rieur est a peu pr s parall le au d flecteur inclin sup rieur Installer un d flecteur en forme de bo te pleine en bois ou en t le d aluminium ou galvanis e 21 a l arri re de l enceinte S assurer que le bas du d flecteur en forme de bo te pleine se trouve entre 21 po et 21 1 2 po au dessus du bas de l enceinte 17 7 1 4 po a 7 3 4 po au dessus du haut de l ouverture de la prise d air inf rieure 18 Veiller ce que l arri re du d flecteur en forme de bo te pleine soit perpendiculaire au bas de l enceinte Veiller ce que l arri re du d flecteur en forme de bo te pleine se trouve soit contre le haut de l enceinte soit contre le d flecteur d angle int rieur 173 selon la conception du v hicule Veiller ce que le d flecteur en forme de bo te pleine soit 1 po ou moins des serpentins 10 et du condenseur 11 du r frig rateur Veiller ce que le d flecteur en forme de bo te pleine fasse toute la largeur de l int rieur de l enceinte 172 173 15 2 EN s H IO LE 0 ART 02486 Installation d une bouche d chappement sup r
11. portes non m talliques Installation du r frig rateur us Connexion descomposants leciriques iria ian Raccordement de l alimentation en courant alternatif 120V eee 15 Raccordement de l alimentation en courant continu 12V Raccordement de chauffage a basse temp rature ambiante option Branchement des l ments du gaz propane iii Rechercher les fuites dans le tuyau d arriv e de gaz propane sise Raccordement de la machine gla ons eeeeceeeeeeeeeeeeeeenteeeeeaes Branchement du tuyau d arriv e d eau Allumage etimise en march TR Inn ea ae aes Allumag el mise en roulet spiana saves pia anatra i basilare china a a E anne teen R regi emeten iles real Les Modes de fonctionnement V rification de la soupape de s ret du gaz Arr t tous mod les Codes d anomalie aissalo tieni ilaria ira Signalisation de la s curit Lire soigneusement ce manuel et en assimiler le contenu avant d installer le r frig rateur Prendre conscience des risques pour la s curit signal s par le symbole de mise en garde sur le r frig rateur et dans ce manuel Le symbole de mise en garde est suivi d un terme pr cisant la nature du risque en question Lire soigneusement la description de ces termes de signalement pour apprendre les diff rencier C est une question de s curit personnelle Ce terme de signalement indique un danger
12. quand les commandes du r frig rateur sont activ es Ces ventilateurs s arr tent quand la temp rature des ailettes du condenseur au thermostat est d environ 115 F ou moins M me avec ces ventilateurs si le flux d air est obstru ou restreint le r frig rateur ne fera pas son travail comme il faut Le syst me de ventilation de chaque mod le NORCOLD est homologu par la section International de l ACNOR Installer uniquement les bouches de ventilation homologu es qui sont sp cifi es dans ce manuel Manuel d installation 4 Dimensions importantes du r frig rateur Ces dimensions importantes du r frig rateur sont donn es titre de r f rence en cas de besoin voir Art02477 Largeur de la caisse du r frig rateur sans garniture 35 60 1 Largeur totale du r frig rateur avec garniture SKOPO e 2 Distance entre la caisse du r frig rateur et la garniture lat rale OO PO 3 Hauteur de la caisse du r frig rateur sans garniture G8 OPO eenn 4 Hauteur totale du r frig rateur avec garniture TOO OISE ne 5 Distance entre la caisse du r frig rateur et la garniture sup rieure 120p0r nE 180 Distance entre le rail inf rieur du r frig rateur et la garniture INTENCUROT iii cities a e 080 DO iii aa nins ai mi 181 Distance entre la paroi de l enceinte et le devant des portes 3 LO a ee et 7 Distance entre le rail inf rieur du r frig rateur et le centre des poign es AA PO rana 8 Assemb
13. rieur vertical du d flecteur en forme de boite pleine se trouve a 1 2 po ou moins 170 sous le coin inf rieur arri re du condenseur 11 et 1 4 po ou moins derri re 15 Installation d un d flecteur d air facultatif Si le plan a le r frig rateur sur la paroi arri re du v hicule effectuer toute l installation des bouches comme d crit a la section Installation des bouches de ventilation sup rieure et inf rieure de ce manuel Installer la bouche d chappement de toit de fa on a ce que l extr mit inclin e de la bouche d chappement du toit se trouve vers l un des c t s du v hicule la bouche d chappement du toit soit perpendiculaire l coulement de lair au dessus du v hicule Installer un d flecteur d air sur le toit du v hicule entre la bouche d chappement du toit et avant du v hicule voir Art01767 S assurer que le d flecteur d air 175 se trouve entre la bouche d chappement du toit 24 et l avant du v hicule a a 179 S assurer que le d flecteur d air fait au moins 3 1 2 po de haut 176 Art01767 S assurer que la largeur totale 177 du d flecteur d air est de 32 7 8 S assurer que la distance entre le d flecteur d air et la bouche d chappement du toit est entre 2 et 3 po 178 Installation des panneaux d coratifs de porte mod les portes non m talliques Les portes sont con ues pour accepter des panneaux d cora
14. rieure et inf rieure l avant du r frig rateur et dans la paroi de l enceinte Pousser les garnitures 40 pour les introduire sur l avant du r frig rateur Ins rer des vis travers la bride de montage l arri re du r frig rateur et dans le plancher 5 Sur les mod les portes m talliques seulement on peut retirer l emballage protecteur des portes AVIS Veiller ne pas rafler ou bosseler les portes m talliques Ne pas se servir de produits de nettoyage abrasifs de produits chimiques ou de tampons a r curer car ils risquent d endommager le fini des portes Art01814 Connexion des composants lectriques Fonctionnement sur C A Tension 120 V c a 132V maxi 108V mini Fonctionnement sur C C Tension de commande 12 V c c 15 4 V maxi 10 5 V mini Le r frig rateur utilise ces sources d alimentation L utilisation de sources hors des limites indiqu es peut endommager les circuits lectriques du r frig rateur et rendra la garantie nulle et non avenue Manuel d installation 14 Brancher le s cordon s d alimentation c a uniquement dans une prise trois lames avec masse Ne pas retirer le contact de terre rond des cordons d alimentation c a Ne pas utiliser un adaptateur deux lames ou une rallonge avec les cordons d alimentation c a L
15. safety valve 6 Close the lower intake vent Shut down all models To shut down the refrigerator push and hold the ON OFF button for one second Installation Manual 19 Fault Codes Fault Codes Fault Code Meaning Corrective Actions dr Audible alarm also The door was open for more than 2 minutes Close the door no EL Audible alarm also The burner did not ignite or re ignite Check That the valve of the propane gas tank s is open That the propane gas is at the correct pressure That the manual shut off valve of the refrigerator is open That there is no air in the propane gas supply line See Removing air from the propane gas supply lines section of the Owner s Manual See your dealer or authorized Norcold Service Center no AC Audible alarm also AC voltage is not available to the refrigerator Check That the refrigerator is plugged into a serviceable outlet That the fuse or circuit breaker or the vehicle is intact That the vehicle generator is operational if applicable See your dealer or authorized Norcold Service Center Lo dc The DC voltage to the refrigerator is low Check That the battery charging equipment of the vehicle is operational That the AC DC converter is operational if applicable See your dealer or authorized Norcold Service Center Lo dc Audible alarm al
16. tube en cuivre de diam ext de 1 4 po pour le tuyau d arriv e d eau OU BIEN tube en plastique de diam ext de 1 4 po pour le tuyau d arriv e d eau robinet d arr t de 1 4 po dans le tuyau d arriv e d eau Ceci doit tre d acc s facile travers la bouche de prise d air inf rieure Branchement du tuyau d arriv e d eau Installer un tuyau d arriv e d eau de diam ext de 1 4 po 43 allant du robinet d arr t d eau 44 du v hicule l lectrorobinet 44 situ l arri re du r frig rateur voir Art02491 Un crou de compression en laiton 45 un manchon AVIS ll en laiton un manchon en plastique 46 et une pi ce rapport e en laiton 47 sont fournis et fix s l arri re _ an du r frig rateur voir Art01604 HH I Placer l crou de compression puis le manchon sur le tuyau d arriv e d eau 43 0 Pour les tubes en cuivre utiliser le manchon en laiton ART 02491 Pour les tubes en plastique utiliser le manchon en plastique 46 Pour les tubes en plastique dont l paisseur des parois est de 0 040 po utiliser galement la pi ce rapport e en laiton 47 Purger le tuyau d arriv e d eau jusqu a ce que l eau soit claire Placer le tube dans l adaptateur 48 jusqu ce qu il bute contre l arr t de ce dernier Serrer l crou de compression la main serrer fortement avec les doigts Art01604 l
17. 08 volts min 12 volts 15 4 volts max 10 5 volts min DC Operation 12 volts 15 4 volts max 10 5 volts min Art01814 This refrigerator operates on these electrical sources Operation out of these limits may damage the refrigerator s electrical circuit parts and will void the warranty Installation Manual 14 The rear of the refrigerator cooling system has hot surfaces and sharp surfaces that can damage electrical Awarnine wiring Make sure that there is a good clearance between all electrical wiring and the cooling system of the refrigerator Position any electrical wiring within the refrigerator enclosure opposite the burner side of the refrigerator Do not put any electrical wiring through the roof exhaust vent Failure to correctly position electrical wiring can result in electrical shock or fire Connect the 120 volts AC supply Awarninc Connect the AC power cord s only to a grounded three prong receptacle Do not remove the round ground prong from any of the AC power cords Do not use a two prong adapter or an extension cord with any of the AC power cords Operation of the refrigerator without correct ground can cause dangerous electrical shock or death if you are touching the metal parts of the r
18. 32 Laici 7 8 Make sure that the distance between the air deflector and the roof exhaust vent is between 2 and 3 inches 178 Install Decorative Door Panels non metal door models NOTICE The doors are made to accept decorative panels The decorative panels must be 3 16 inch or less in thickness Install the decorative door panels in the refrigerator doors before installing the refrigerator in the vehicle 1 Make two upper door panels that are 17 1 4 inches wide x 23 1 8 inches high Raised panels must be centered on each door and no larger than 16 1 2 inches wide x 22 3 8 inches high 2 Make two lower door panels that are 17 1 4 inches wide x 42 5 16 inches high Raised panels must be centered on each door and no larger than 16 1 2 inches wide x 41 9 16 inches high 3 Install the decorative door panels Pull the panel retainer 37 off of each door 39 See Art01804 Push a decorative door panel 38 into the slots of each door Art01804 Installation Manual 12 Make sure that each panel retainer is correctly positioned and push the curved snaps 125 of the panel retainer 37 inside of the curved snaps 126 of the door See Art01805 Install the Refrigerator Va I NY 1 ag NS y Art01805 When manually by hand or mechanically by hoist lift truck etc handling a refrigerator that is not installe
19. NO to the rear of the condenser 22 and is 61 35 in min to 61 65 in max from the bottom of the refrigerator to the bottom of the refrigerator condenser 23 See Art02487 Install the upper side wall exhaust vent 24 so that the distance 25 from the bottom of the enclosure to the top of the rough opening for the upper exhaust vent is at least 71 0 inches See Art02487 and Art02488 H Align the upper exhaust vent horizontally above the lower intake vent 9 ART 02487 Installation Manual 10 Install the Baffles for an Upper Side Wall Exhaust Vent Make sure that all horizontal baffles are the full width of the inside of the enclosure and are in the correct location If the baffles are not the full width of the enclosure or incorrectly located poor cooling performance can result If the enclosure depth is 24 inches or more and less than 26 inches See Art02488 Install a wood aluminum or galvanized steel top baffle 13 between the top of the refrigerator and the top of the upper exhaust vent 24 Make sure that the top baffle is less than 1 4 inch 15 from the top of the refrigerator and baffle overlaps the refrigerator 1 inch or less Make sure that the baffle is against the wall of the vehicle at the top of the upper exhaust vent and less than 1 4 inch above the opening for the upper exhau
20. NORCOLD Va i m Installation Manual for the 2118X series of RV Refrigerators The letter X in the model numbers above stands for letters or numerals which means a refrigerator option Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information contact a qualified installer service agency or the gas supplier Awarnina FIRE OR EXPLOSION HAZARD If you smell gas 1 Open Windows 2 Do not attempt to light appliance 3 Do not touch electrical switches 4 Extinguish any open flame 5 Shut off fuel supply 6 Evacuate immediately and call emergency services Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance Awarninc DO NOT install this refrigerator in below deck marine applications Do not install this refrigerator in a fixed indoor cabin or other dwelling applications This refrigerator must use only NORCOLD designed and approved outside air intake and exhaust ventilation for correct and safe operation Any other ventilation could cause lethal combustion exhaust fumes and or explosive propane gas fumes to be in the living area and or to be below deck Norcold Customer Support Dept
21. and can ignite and burn with an intense flame Do not bend drop weld move drill puncture or hit the cooling system The rear of the refrigerator has sharp edges and corners To prevent cuts or abrasions when working on the refrigerator use caution and wear cut resistant gloves Make sure that the refrigerator is stored in a location so that it is not exposed to the elements of the weather Certification and Code Requirements This refrigerator is certified by CSA International as meeting the latest edition of ANSI Z21 19 CSA 1 4 standards for installation in mobile homes or recreational vehicles The installation must obey these standards and this Installation Manual for the NORCOLD limited warranty to be in effect Installation must conform with the following as applicable CERTIFIED Art01290 Installation Manual 3 In the United States and Canada Local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 the Natural Gas and Propane installation Code CSA B149 1 ANSI A119 2 Recreational Vehicles Code and CSA Z240 RV Series Recreational Vehicles Amanufactured home mobile home installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 part 280 and the current CSA Z240 4 Gas equipped Recreational Vehicles and Mobile Housing
22. ator frame See Art01808 Mwanne Make sure the foam combustion seal is not broken is completely around the refrigerator mounting flanges and is between the mounting flanges and the wall of the enclosure If the seal is not complete exhaust fumes can be present in the living area of the vehicle The breathing of exhaust fumes can cause dizziness nausea or in extreme cases death 3 Put the refrigerator in position NOTICE Be careful when you put the refrigerator into position It is not necessary to remove the protective packaging from the doors of metal door models to install or operate the refrigerator Make sure that the flue cap is not pushed down against the top of the flue tube Push the refrigerator completely into the enclosure 4 Install the mounting screws and trim See Art01814 Put the four screws 41 through both the upper and the lower mounting flanges on the front of the refrigerator and into the enclosure wall Push the trim pieces 40 onto the front of the refrigerator Put screws through the mounting flange on the rear of the refrigerator and into the floor 5 On metal door models only you may wish to remove the protective packaging from the doors Be careful to not scratch or dent the metal doors Do not use NOTICE any abrasive cleaners chemicals or scouring pads because they can damage the fininish of the doors Connect the Electrical Components AC Operation 120 volts 132 volts max 1
23. construction debris is on the refrigerator or in the enclosure Debris can cause a combustion hazard and prevent the refrigerator from operating correctly Tighten the screws of the upper roof exhaust cap to 10 inch pounds max NOTICE X fa Also make sure that the air flow around the upper roof exhaust cap is not blocked or decreased by other roof mounted features such as a luggage carrier an air conditioner a solar panel etc 2 Align the upper roof exhaust vent above the lower intake exhaust vent 3 Determine the type of enclosure in a vehicle using an upper roof exhaust vent See Art02480 If the distance from the face of the enclosure to the inboard edge of the roof exhaust vent opening 169 is more than 17 1 2 inches install the roof exhaust vent 12 directly above the condenser 11 of the refrigerator as a vertical enclosure ART 02480 If the distance from the face of the enclosure to the inboard edge of the roof exhaust vent opening 169 is 17 1 2 inches or less install the roof exhaust vent 12 inboard from the condenser 11 of the refrigerator as an offset vertical enclosure Install the Baffles for an Upper Roof Exhaust Vent Make sure that all horizontal baffles are the full width of the inside of the enclosure and are in the correct location If the baffles are not the full width of the
24. d in an enclosure the best method is while the refigerator is in its original packaging If the refrigerator is not in its original packaging use the handling straps 183 of the refrigerator cabinet as the primary load carrying points See Art0290 There are two 2 handling straps on both the right and left side of the refrigerator cabinet These handling straps may be used to lift move and tilt the refrigerator Norcold recommends that all lifting moving and tilting of the refrigerator is always done by at least 2 persons Use only the handling straps to lift move or tilt the refrigerator Using any part of the refrigerator other than the handing straps to lift move or tilt it can result in damage to the refrigerator 1 Remove the packaging support block See Art01850 Open both lower doors of the refrigerator Remove and discard the two screws 41 from the front of the lower mounting flange of the refrigerator Tilt the refrigerator back just enough to remove the wooden packaging support block 209 from behind the lower mounting flange Close the doors 2 Put the refrigerator completely into the enclosure Push below the center of the refrigerator Es CO Peay on Lu nt nt LL ART 02490 Installation Manual 13 Pull using a wire form tool hooked into mounting holes 121 of the refriger
25. e MODE button 31 to scroll through the available operation modes of the refrigerator one after the other When the desired mode indicator comes on in the LCD release the MODE button Or push and release the MODE button again and again to change the available operation modes of the refrigerator one at a time As you change the mode the applicable mode indicator will come on ART 02492 Installation Manual 18 On 2 way models the mode indicators are See Art02493 Auto mode AC electric 281 Auto mode gas 282 Manual mode AC electric 283 Manual mode gas 284 3 Select the temperature setting Push and hold the TEMPERATURE SET button 32 to scroll through the temperature settings one after the other See Art02492 Or push and release the TEMPERATURE SET button again and again to change the temperature settings one at a time The temperature settings 278 come on as numbers in the LCD Select one of nine 9 temperature settings One 1 is the warmest temperature setting Nine 9 is the coldest temperature setting Do a test of the gas safety valve 1 Start up the refrigerator in the manual mode operation 2 Open the lower intake vent 3 Remove one wire from the solenoid of the gas safety valve at the rear of the refrigerator 4 Within 30 seconds the flame should extinguish This means that the gas safety valve is operating correctly 5 Put the wire back on the solenoid of the gas
26. e de s ret du gaz 1 2 6 Mettre le r frig rateur en route en mode manuel Ouvrir la prise d air inf rieure D brancher un fil du sol noide de la soupape de s ret du gaz l arri re du r frig rateur Rebrancher le fil au sol no de de la soupape de s ret Fermer la prise d air inf rieure Arr t tous mod les Pour arr ter le r frig rateur enfoncer et maintenir enfonc le bouton ON OFF pendant un seconde La flamme doit s teindre dans les 30 secondes ce qui confirme le bon fonctionnement de la soupape de s ret 19 Manuel d installation Codes d anomalie Code de d faillance Signification Actions correctives dr Avec alarme sonore La porte est rest e ouverte pendant plus de 2 minutes Fermer la porte no FL Avec alarme sonore Le br leur n est pas allum ou rallum V rifier Que le robinet du des r servoir s de propane est sont ouvert s Que la pression du gaz propane est correcte Que le robinet d arr t manuel de r frig rateur est ouvert Qu il n y a pas d air dans le tuyau d arriv e de gaz propane Voir la section Purge d air des tuyaux d arriv e de gaz propane dans le manuel d utilisation Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold no AC Avec alarme sonore Lo dc La tension c a n est pas disponibl
27. e vers le r frig rateur La tension c c vers le r frig rateur est faible V rifier Que le r frig rateur est branch dans une prise qui fonctionne Que le fusible ou le disjoncteur du v hicule est intact Que la g n ratrice du v hicule est op rationnelle si elle existe Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold V rifier Que le syst me de charge de la batterie du v hicule est op rationnel Que le convertisseur C A C C est op rationnel si existe Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold Lo de Avec alarme sonore La tension c c vers le r frig rateur est faible V rifier Que le syst me de charge de la batterie du v hicule est op rationnel Que le convertisseur C A C C est op rationnel si existe Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold Sp Avec alarme sonore Il s agit d une anomalie l int rieur m me des commandes du r frig rateur COUPER l alimentation du r frig rateur puis la r tablir pour le r initialiser Si le code d anomalie persiste consulter le concessionnaire ou un centre de service apr s vente agr Norcold Le r glage de temp rature clignote lorsque l on appuie sur le bouton REGLAGE TEMP ou MODE Le r frig rateur fonctionne sur le syst me de fonctionnement de sec
28. ecter Ce r frig rateur est homologu par la section International de l ACNOR comme conforme la derni re dition des normes ANSI Z21 19 CSA 1 4 en ce qui concerne l installation dans des caravanes r sidentielles ou v hicules de loisir Pour que la garantie limit e NORCOLD puisse entrer en vigueur l installation doit tre conforme ces normes et au pr sent 4 Manuel d installation Linstallation doit respecter les l ments suivants lorsqu ils sont applicables CERTIFIED Art01290 3 Manuel d installation Aux tats Unis et au Canada Les codes locaux ou d faut le code National Fuel Gas Code les normes ANSI Z223 1 NFPA 54 le code Natural Gas and Propane installation Code la norme ACNOR B149 1 le code ANSI A119 2 Recreational Vehicles Code et les normes ACNOR Z240 RV Series Recreational Vehicles L installation des maisons pr fabriqu es caravanes r sidentielles doit se conformer la norme Manufactured Home Construction and Safety Standard titre 24 CFR partie 3280 anciennement d nomm e Federal Standard for Mobile Home Construction and Safety titre 24 partie 280 et la norme jour ACNOR Z240 4 Gas equipped Recreational Vehicles and Mobile Housing Si une source d alimentation externe est employ e l appareil lectrom nager doit son installation faire l objet d une mise la terre lectrique conforme aux codes locaux ou d faut de tels codes con
29. efrigerator Put the AC power cord s into a grounded three prong receptacle Make sure the receptacle is positioned within easy reach of the lower intake vent Make sure the power cord s does not touch the burner cover the flue pipe or any hot component that could damage the insulation of the power cord Connect the 12 volts DC supply As the distance from the vehicle battery to the refrigerator increases the correct AWG wire size and fuse size also increases If the wire size is too small for the distance a voltage drop occurs The voltage drop decreases the output of the system heater and causes poor cooling performance 1 Determine the min wire size and the max fuse size to use Awarninc If you use an incorrect wire size and or fuse size o electrical fire can result On 2 way models use a minimum of 18 AWG wire and a maximum 6 Amp D fuse 2 Install a fuse in DC povver supply vvires betvveen the battery and the refrigerator Put fuse as close to the battery as possible 3 Connect the DC power supply wires See Art02402 Attach a 1 4 inch Quick Connect terminal to each DC power supply wire Push the positive DC power wire onto the power board terminal that is marked 12VDC 288 Art02402 Push the DC ground wire onto the power board terminal that is marked GND 287 Make sure each DC power supply wire is on the cor
30. ement du toit 12 directement au dessus du condenseur 11 du r frig rateur comme pour une enceinte verticale Si la distance depuis la face de l enceinte au bord int rieur de l ouverture 169 de la bouche d chappement du toit est inf rieure ou gale 17 1 2 po installer la bouche d chappement du toit 12 vers l int rieur par rapport au condenseur 11 du r frig rateur comme pour une enceinte verticale d cal e Installation de d flecteurs pour une bouche d chappement sup rieure de toit Veiller ce que tous les d flecteurs horizontaux fassent toute la largeur de l int rieur de l enceinte et soient au bon endroit Si ce n est pas le cas on risque d obtenir un mauvais refroidissement 15 13 Enceintes verticales Si la profondeur de l enceinte est sup rieure ou gale 24 po et inf rieure 25 po voir Art02481 Poser un d flecteur sup rieur 13 Veiller a ce qu il y ait un d gagement de moins de 1 4 po 15 entre le d flecteur et le haut du r frig rateur ART 02481 7 Manuel d installation Si la profondeur de l enceinte est sup rieure ou gale a 25 po et inf rieure a 26 po voir Art02482 Poser un d flecteur sup rieur 13 ge Veiller a ce qu il y ait moins de 1 4 po 15 entre le d flecteur sup rieur et le LES haut du r frig rateur 3 7 lt 19 Poser un d flecteur de condenseur 16 au bord le plus bas du conden
31. enclosure or incorrectly located poor cooling performance can result Vertical enclosures If the enclosure depth is 24 inches or more and less than 25 inches See Art02481 Install a top baffle 13 Make sure there is less than 1 4 inch clearance 15 between the baffle and the top of the refrigerator EN 5 al ART 02481 Installation Manual 7 If the enclosure depth is 25 inches or more and less than 26 inches See Art02482 15 13 Install a top baffle 13 Make sure that the top baffle is less than 1 4 inch 15 from the top of the refrigerator Install a condenser baffle 16 at the lowest edge of the condenser of the refrigerator Make sure that the condenser baffle is 1 inch or less 19 from the condenser Install an absorber baffle 171 18 inches to 18 1 2 inches above the bottom of the enclosure 17 4 1 4 inches to 4 3 4 inches above the top of the lower intake vent opening 18 Make sure that the absorber baffle is 1 inch or less 19 from the absorber If the enclosure depth is 26 inches or more See Art02483 Install a top baffle 13 Make sure that the top baffle is less than 1 4 inch 15 from the top of the refrigerator Install a wood or an aluminum o
32. errer les raccords du tuyau d arriv e de gaz propane S assurer de la conformit de l installation lectrique a tous les codes applicables Voir la section Certification et codes respecter Ne pas contourner ou modifier les composants ou fonctions lectriques du r frig rateur Ne pas vaporiser de liquides pr s des prises lectriques des raccords ou des pi ces du r frig rateur Nombre de liquides sont conducteurs et peuvent poser des risques de d charge lectrique de court circuit voire m me d incendie Le syst me frigorifique du r frig rateur est sous pression Ne pas essayer de r parer ou recharger un syst me frigorifique d fectueux Le syst me frigorifique contient du chromate de sodium L inhalation de certains compos s du chrome peut causer le cancer Le syst me frigorifique contient des produits chimiques qui peuvent causer de graves br lures la peau et aux yeux s enflammer et br ler avec une flamme intense Ne pas recourber faire tomber souder d placer percer perforer ou heurter le syst me frigorifique L arri re du r frig rateur pr sente des ar tes vives et des angles coupants Pour viter de se couper ou de s corcher lors du travail sur le r frig rateur faire attention et porter des gants r sistant aux coupures S assurer que le r frig rateur est entrepos dans un endroit o il n est pas expos aux intemp ries Certification et codes resp
33. es Water Column If the pressure of the compressed air is more than 1 2 psig 14 inches Water Column remove the gas supply line from the bulkhead fitting of the refrigerator before the test If the pressure of the compressed air is equal to or less than 1 2 psig 14 inches Water Column close the manual shut off valve of the refrigerator before the test Installation Manual 16 Connect the Ice Maker Optional The ice maker maybe assembled to the refrigerators at the factory The refrigerator installer must connect a cold water supply line to the solenoid valve at the rear of the refrigerator The following are necessary to connect the icemaker 1 4 in OD copper tubing for the water supply line OR 1 4 in OD plastic tubing for the water supply line 1 4 in shut off valve in the water supply line This should be easily accessible through the lower intake vent Connect the water supply line Install a 1 4 in OD water supply line 43 from the water shut off valve 44 of the vehicle to the solenoid water valve 44 at the rear of the refrigerator See Art02491 NOTICE A brass compression nut 45 a brass sleeve a plastic sleeve 46 and a brass insert 47 are supplied and attached to the rear of the refrigerator See Art01604 Put the compression nut and then the sleeve onto the water supply line 43 For copper tubing use the brass sleeve ART 02491 For plastic tubing use the plast
34. forme au code National Electrical code et aux normes ANSI NFPA 70 ou au Code canadien d lectricit ACNOR C22 2 parties 1 et 2 Tous les tuyaux et raccords d arriv e de gaz propane doivent respecter les codes locaux provinciaux et f d raux s appliquant a leurs types et dimensions Ces l ments doivent galement tre conformes la norme a jour NFPA 1192 section 2 4 et au Canada ala norme a jour CAN 1 6 10 Consignes relatives a la ventilation Aavertissement Conditions a satisfaire par l installation Il doit y avoir un apport d air frais suffisant pour la combustion L espace de s jour doit tre compl tement isol du syst me de combustion du r frig rateur Le conduit de fum e d chappement doit b n ficier d une ventilation totale et sans restriction car en mode de fonctionnement au gaz du monoxyde de carbone peut en sortir L inhalation de fum es contenant du monoxyde de carbone peut causer des vertiges des naus es ou dans les cas extr mes la mort S assurer de l isolation compl te du r frig rateur par rapport ses composants produisant de la chaleur en utilisant un jeu appropri de d flecteurs et de panneaux Une installation homologu e requiert une prise d air inf rieure et une bouche d chappement sup rieure Installer la prise d air et la bouche d chappement exactement comme d crit dans ce manuel Toute autre m thode d installation annulerait la fois l
35. frig rateur s il devient mouill et s il y a du vent combustion 5 La face avant de l enceinte doit tre perpendiculaire l tag re pour cr er un joint de j 6 L ouverture de la d coupe doit tre carr e et perpendiculaire l tag re de l enceinte pour maintenir l alignement de la porte ART 02478 7 En se servant du tableau suivant d cider des tailles de bouches de ventilation et de d coupes D utiliser Bouche de ventilation homologu e R f Hauteur D Largeur D Came d chappement sup rieure du toit 622293 S O S O 625240 S O S O Bouche d chappement sup rieure du toit 616319 24 po 5 1 4 po 625161 24 po 5 1 4 po Bouche d chappement sup rieure en plastique et prise d air inf rieure 628073 13 3 4 po 29 5 16 po Installation de la prise d air inf rieure Poser la prise d air inf rieure voir Art02479 TUEJ La prise d air inf rieure sert galement d ouverture d acc s aux composants l arri re du r frig rateur Veiller ce que le bas de l ouverture A avertissemenT de la prise d air inf rieure soit de niveau avec le sol ou juste en dessous Ainsi s il y a fuite du gaz propane il s chappe l ext rieur au lieu de s accumuler au niveau du sol Veiller ce que le bas de louverture de la prise d air inf rieure 9 soit de niveau avec le sol ou juste en dessous
36. homologation et la garantie d usine du r frig rateur Le bas de l ouverture de la prise d air inf rieure qui est aussi la porte d acc s de service doit tre de niveau avec le sol ou juste en dessous Ainsi s il y a fuite du gaz propane il s chappe l ext rieur au lieu de s accumuler au niveau du sol En vertu de l homologation de la section International de l ACNOR il peut y avoir un d gagement nul sur les c t s l arri re le haut et le bas du r frig rateur Alors qu aucun d gagement maximum n est sp cifi par l homologation le r frig rateur ne peut fonctionner correctement que si les d gagements maximum suivants sont respect s Bas 0 po min 0 po max Chaque c t 0 po min 1 2 po max Haut 0 po min 1 4 po max Arri re 0 po min 1 po max Ces d gagements ainsi que la prise d air inf rieure et la bouche d chappement sup rieure permettent l coulement d air naturel requis pour une bonne r frig ration De l air plus froid entre par la prise d air inf rieure monte en traversant les serpentins du r frig rateur o il limine l exc dent de chaleur des composants du r frig rateur et il sort par la bouche d chappement sup rieure Le r frig rateur a galement ventilateurs contr l s par thermostat pour d placer l air travers le syst me frigorifique Ces ventilateurs se mettent en marche quand la temp rature des ailettes du condenseur au thermostat est d environ 130 F ou plus et seulement
37. ic sleeve 46 For plastic tubing with 040 in wall thickness also use the brass insert 47 Flush the water supply line until the water is clear Put the tubing into the adapter 48 until it is against the stop of the adapter Tighten the compression nut by hand hard finger tight Using two wrenches tighten the compression nut 1 to 2 turns Open the water shut off valve of the vehicle Art01604 Examine the connections for leaks Installation Manual 17 Ignition and Start Up Before ignition or start up of the refrigerator Make sure the air flow in the lower intake vent through the refrigerator coils and condenser and out the upper exhaust vent is not blocked or decreased Make sure there are no combustible materials in or around the refrigerator Ignition and start up NOTICE If the gas does not ignite within 30 seconds the gas valve of the refrigerator will automatically close the igniter will stop sparking an audible alarm will sound and the fault codes no FL will flash on the LCD 280 To reset the controls press and hold the POWER ON OFF button 30 for 1 second to turn the refrigerator off and then press it again to restart the refrigerator See Art02492 If the gas does not ignite after several attempts refer to the Fault Codes section of this manual Modes of Operation 1 Push and release the POWER ON OFF button 30 2 Select the mode of operation Push and hold th
38. ide wall of the vehicle Make sure that the inside corner baffle is approximately parallel to the angled top baffle If the enclosure depth is 25 inches or more and less than 26 inches See Art02485 Install an angled top baffle 172 between the top rear edge of the refrigerator and the inside edge of the upper exhaust vent opening Make sure that the angled top baffle is less than 1 4 inch 15 from the top of the refrigerator Make sure that the angled top baffle is no more than 45 from vertical 20 Install an inside corner baffle 173 between the outside edge of the upper exhaust vent opening and the side wall of the vehicle Make sure that the inside corner baffle is approximately parallel to the angled top baffle ART 02484 Install a condenser baffle 16 at the lowest edge of the condenser of the refrigerator Make sure that the condenser baffle is 1 inch or less 19 from the condenser Install an absorber baffle 171 21 inches to 21 1 2 inches above the bottom of the enclosure 17 21 1 4 inches to 4 3 4 inches above the top of the lower intake vent opening 18 Make sure that the absorber baffle is 1 inch or less 19 from the absorber ART 02485 Installation Manual 9 If the enclosure depth is 26 inches or more See Art02486 Install an angled top baffle 172 between the top rear edge of the refrigerator and the inside edge of the upper exhaust vent opening Make sure that
39. ieure de paroi lat rale o z Si la conception du v hicule emp che l installation d une bouche d chappement de toit installer une bouche d chappement sup rieure de paroi lat rale Le r frig rateur mesure entre 23 75 po min et 24 05 po max depuis l arri re du AVIS disjoncteur jusqu l arri re du condenseur 22 et entre 61 35 po min et 61 65 po max du bas du r frig rateur jusqu au bas du condenseur du r frig rateur 23 voir Art02487 Installer la bouche d chappement sup rieure de paroi lat rale 24 de fagon a ce que la distance 25 entre le bas de l enceinte et le haut de la d coupe pour la bouche d chappement sup rieure soit d au moins 71 0 po voir Art02487 et Art02488 Aligner la bouche d chappement sup rieure l horizontale au dessus de la prise d air inf rieure 9 ART 02487 Manuel d installation 10 Installation de d flecteurs pour une bouche d chappement sup rieure de paroi lat rale Veiller ce que tous les d flecteurs horizontaux fassent toute la largeur de l int rieur de l enceinte et soient au bon endroit Si ce n est o pas le cas on risque d obtenir un mauvais refroidissement Si la profondeur de l enceinte est sup rieure ou gale 24 po et inf rieure a 26 po voir Art02488
40. ion Manual 21 NORCOLD Manuel d installation pour la s rie 2118X de r frig rateurs pour les v hicules de loisir La lettre X dans les num ros de mod le ci dessus repr sente lettres ou un chiffres correspondant une option de r frig rateur g r paration ou d entretien peut causer des pr judices corporels ou mat riels Se reporter ce manuel Pour obtenir de assistance ou des informations suppl mentaires s adresser un installateur qualifi au service apr s vente ou la compagnie de gaz AVERTISSEMENT RISQUE D INDENDDIE OU D EXPLOSION Si vous sentez une odeur de gaz 1 Ouvrez les fen tres 2 teignez toute flame nue 3 Ne pas toucher les interrupteurs lectiques 4 teignez toute flame nue 5 Coupez l alimentation en combustible 6 Evacuez imm diatement et applez les services d urgence Ne pas suivre ces instructions peut provoquer in incendie ou un explosion pouvant causer des dommages mat riels des blessures ou la mort S CURIT PERSONNELLE Ne pas conserver ni utiliser d essence ou d autres liquides inflammables ou dont les vapeurs peuvent s enflammer proximit de cet appareil ou de tout autre appareil lectrom nager A avertissemenT NE PAS installer ce r frig rateur sous le pont dans un bateau Ne pas installer ce r frig rateur dans une cabine fixe ou autre zone habitable int rieure Pour fonctionner correctement et sans danger ce r frig
41. l state and national codes about size and type Make sure that all flexible metal connectors obey the current CAN1 6 10 Standard Make sure that the materials used for the gas supply line obey both the current ANSI A 119 2 NFPA 1192 and CSA Z240 Standards on Recreational Vehicles Norcold recommends the use of 3 8 inch copper tubing as the gas supply line and requires a 3 8 inch SAE UNF 5 8 18 male flare fitting as the connection to the refrigerator Put the propane gas supply line up through the floor of the enclosure Make sure the hole through the floor is large enough allow clearance for the gas supply line Put a weather resistant seal grommet sealant etc around the gas supply line where it goes through the floor to prevent vibration and abrasion To prevent vibration and abrasion make sure that the gas supply line is not against anything in the enclosure Attach the gas supply line to the bulkhead fitting of the refrigerator Examine the propane gas supply line for leaks Awarnine Do not allow the leak detecting solution to touch the electrical components Many liquids are electrically conductive and can cause electrical shorts and in some cases fire Use a leak detecting solution to examine the gas supply line and all propane gas connections for leaks If you use compressed air for the test The pressure of the compressed air at the manual shut off valve of the refrigerator must not be more than 1 2 psig 14 inch
42. l gas butane etc Incorrect installation adjustment alteration or maintenance of this refrigerator can cause personal injury property damage or both Obey the instructions in this manual to install intake and exhaust vents Do not install the refrigerator directly on carpet Put the refrigerator on a metal or wood panel that extends the full width and depth of the refrigerator Do not allow anything to touch the refrigerator cooling system Propane gas can ignite and cause an explosion that can result in property damage personal injury or death Do not smoke or create sparks Do not use an open flame to examine the propane gas supply line for leaks Always use two wrenches to tighten or loosen the propane gas supply line connections Make sure the electrical installation obeys all applicable codes See Certification and Code Requirements section Do not bypass or change the refrigerator s electrical components or features Do not spray liquids near electrical outlets connections or the refrigerator components Many liquids are electrically conductive and can cause a shock hazard electrical shorts and in some cases fire The refrigerator cooling system is under pressure Do not try to repair or to recharge a defective cooling system The cooling system contains sodium chromate The breathing of certain chromium compounds can cause cancer The cooling system contents can cause severe skin and eye burns
43. lage de l enceinte destin e au r frig rateur 6 ART 02477 1 V rifier que l tag re de l enceinte est solide et horizontale Conditions satisfaire par l tag re de l enceinte Il doit s agir d un panneau m tallique ou de bois s tendant au moins sur toute la largeur et toute la profondeur de l enceinte elle doit pouvoir supporter le poids du r frig rateur et de son contenu elle doit tre de niveau pour maintenir l alignement de la porte 2 S assurer qu il ny a pas de sources de chaleur adjacentes telles que bouches de ventilation de chauffage ou de chauffe eau 5 Manuel d installation 3 Veiller ce que l enceinte mesure de 68 94 69 06 po de hauteur x 35 94 a 36 04 po de largeur x 24 00 24 13 po de profondeur AVIS Mesurer la profondeur de l enceinte 174 depuis la face int rieure de l enceinte a l int rieur de la paroi arri re voir art02478 4 S il y a plus de 1 2 po entre un c t du r frig rateur et l int rieur de l enceinte Remplir l espace d isolant en natte en fibre de verre ou ajouter un d flecteur pour liminer le d gagement L arri re de l isolant en natte doit tre entre 18 et 19 po de la face de l enceinte N Bien fixer l isolant en natte l enceinte de fa on ce qu il reste dans cette position durant l installation du r
44. ment avec un palan un chariot l vateur etc un r frig rateur qui n est pas install dans une enceinte est de le faire quand le r frig rateur est dans son emballage d origine Si le r frig rateur n est pas dans son emballage d origine utiliser les sangles de manutention 183 de sa caisse comme points porteurs primaires voir Art02490 Il y a deux 2 sangles de manutention sur les c t s droit et gauche de la caisse du r frig rateur Ces sangles de manutention peuvent tre utilis es pour soulever d placer et incliner le r frig rateur Norcold recommande que toute op ration visant soulever d placer et incliner le r frig rateur soit toujours effectu e par au moins 2 personnes Se servir uniquement des sangles de A arrenrionl manutention pour soulever d placer et incliner le r frig rateur L utilisation de toute autre partie du r frig rateur pour le soulever le d placer ou l incliner risque d endommager le r frig rateur ql a 1 Retrait du bloc de support d emballage voir Art01850 Ouvrir les deux portes inf rieures du r frig rateur Retirer et jeter les deux vis 41 de l avant de la bride de montage inf rieure du r frig rateur Incliner le r frig rateur vers l arri re juste assez pour retirer le bloc de support d emballage en bois 209 derri re la bride de montage inf rieure
45. mmediately below the floor level This allows any leaking propane gas to escape to the outside and not to collect at floor level CSA International certification allows the refrigerator to have zero 0 inch minimum clearance at the sides rear top and bottom While there are no maximum clearances specified for certification the following maximum clearances are necessary for correct refrigerator performance Bottom 0 inch min 0 inch max Each Side 0 inch min 1 2 inch max Top 0 inch min 1 4 inch max Rear 0 inch min 1 inch max These clearances plus the lower and upper vents allow the natural air draft that is necessary for good refrigeration Cooler air comes in through the lower vent goes up around the refrigerator coils where it removes the excess heat from the refrigerator components and goes out through the upper vent The refrigerator also has thermostat controlled fans to move air across the cooling system These fans turn on when the condenser fin temperature at the thermostat is about 130 F or higher and only when the refrigerator controls are on These fans turn off when the condenser fin temperature at the thermostat is about 115 F or less Even with these fans if the air flow is blocked or decreased the refrigerator will not cool correctly Each NORCOLD model is certified by CSA International for correct ventilation Install only the certified vents that are listed in this manual Installation Manual 4 Key Refrige
46. nsion diminue le rendement du syst me de chauffage et affecte donc la capacit de refroidissement du r frig rateur 1 D terminer la section minimale du fil et le calibre maximal du fusible a utiliser Aavertissement L utilisation d un fil et ou d un fusible de calibre incorrect peut d clencher un feu lectrique Pour les r frig rateurs a double alimentation utiliser un fil de calibre 18 AWG minimum et un fusible de 6A maximum Pour les r frig rateurs a triple alimentation mesurer la distance entre la batterie du v hicule et le r frig rateur Sile calibre du fil est sup rieur au minimum choisir le fusible appropri suivant la norme RVIAA 119 2 ou les codes locaux applicables 2 Installer un fusible sur les fils d alimentation en courant continu entre la batterie et le r frig rateur Placer le fusible le plus pr s possible de la batterie 3 Connecter les fils d alimentation en courant continu se reporter See Art02402 Fixer une borne a raccordement rapide de 1 4 pouce chaque fil d alimentation en courant continu Connecter le fil d alimentation positif a la borne du panneau identifi e 12 VDC 288 Connecter le fil de mise la terre a la borne du panneau identifi e GND 287 S assurer que chaque fil d alimentation en courant continu est raccord a la borne avec la polarit correcte Art02402
47. o te pleine soit 1 po ou moins 19 des serpentins 10 et du condenseur 11 du r frig rateur Veiller ce que le d flecteur en forme de bo te pleine fasse toute la largeur de l int rieur de l enceinte ART 02483 Manuel d installation 8 Enceintes verticales d cal es Si la profondeur de l enceinte est sup rieure ou gale a 24 po et inf rieure a 25 po voir Art02484 Poser un d flecteur inclin sup rieur 172 entre le bord sup rieur arri re du r frig rateur et le bord int rieur de louverture de la bouche d chappement sup rieure Veiller a ce qu il y ait moins de 1 4 po 15 entre le d flecteur inclin sup rieur et le haut du r frig rateur S assurer que le d flecteur inclin sup rieur n est pas a plus de 45 de la verticale 20 Poser un d flecteur d angle int rieur 173 entre le bord ext rieur de l ouverture de la bouche d chappement sup rieure et la paroi lat rale du v hicule S assurer que le d flecteur d angle int rieur est a peu pr s parall le au d flecteur inclin sup rieur Si la profondeur de l enceinte est sup rieure ou gale 25 po et inf rieure 26 po voir Art02485 Poser un d flecteur inclin sup rieur 172 entre le bord sup rieur arri re du r frig rateur et le bord int rieur de louverture de la bouche d chappement sup rieure Veiller a ce qu il y ait moins de 1 4 po 15 entre le d flecteur inclin s
48. of the enclosure ART 02488 ART 02489 Installation Manual 11 Make sure that the horizontal top of the solid box baffle is even with the bottom edge of the upper exhaust vent 24 Make sure that the vertical top edge of the solid box baffle is 1 2 inch or less 170 below and 1 4 inch or less behind 15 the lower rear corner of the condenser 11 Install an Air Deflector optional If the floor plan has the refrigerator on the rear wall of the vehicle obey all of the vent installation as written in the Install the Lower and Upper Vents section of this manual Install the roof exhaust vent so that The sloped end of the roof exhaust vent is toward either side of the vehicle The roof exhaust vent is perpendicular to the air flow over the ca lA vehicle Install an air deflector on the roof of the vehicle between the roof exhaust vent and the front of the vehicle See Art01767 Make sure that the air deflector 175 is between the roof exhaust vent 24 and the front of the vehicle 179 Make sure that the air deflector is at least 3 1 2 inches high 176 A Make sure that the overall width 177 of the air deflector is
49. ours Aucune action corrective par l utiliateur propri taire Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold AC TE Avec alarme sonore Il s agit d une anomalie l int rieur m me des commandes du r frig rateur Aucune action corrective par l utiliateur propri taire Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold AC HE Avec alarme sonore Il s agit d un probl me li la chaufferette c c Aucune action corrective par l utiliateur propri taire Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold oP LI Avec alarme sonore Un interrupteur de limite de temp rature est ouvert Aucune action corrective par l utiliateur propri taire Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold Ep o Avec alarme sonore Une flamme est pr sente au niveau du br leur alors qu il ne devrait pas y en avoir Aucune action corrective par l utiliateur propri taire Entrer en rapport avec le concessionnaire ou la Centre d entretien autoris Norcold Manuel d installation 20 21 Manuel d installation
50. qui s il n est pas pris en compte peut causer une blessure grave la mort ou d importants d gats mat riels Ce terme de signalement indique un danger qui s il n est pas pris en compte peut causer une blessure l g re ou d importants d gats mat riels Manuel d installation 2 Consignes relatives la s curit Ce r frig rateur n est pas destin a servir de r frig rateur amovible Il est congu pour fonctionner au gaz propane seulement et ne peut pas tre modifi pour utiliser d autres carburants gaz naturel butane etc Une faute d installation de r glage de modification ou d entretien de ce r frig rateur peut causer des pr judices corporels et ou mat riels Observer les consignes de ce manuel pour installer des bouches de ventilation prise d air et chappement Ne pas installer le r frig rateur m me une moquette ou un tapis Le placer sur un panneau de m tal ou de bois s tendant au moins sur toute sa largeur et toute sa profondeur Ne pas laisser quoi que ce soit toucher le syst me frigorifique du r frig rateur Le gaz propane est susceptible de s enflammer et de causer une explosion et par cons quent des d g ts mat riels et des blessures graves ou mortelles Ne pas fumer ni faire d tincelles Ne pas se servir d une flamme nue pour rechercher les fuites au tuyau d arriv e de gaz propane Toujours se servir de deux cl s pour serrer ou dess
51. r galvanized sheet solid box baffle 21 in the rear of the enclosure Make sure that the bottom of the solid box baffle is 21 inches to 21 1 2 inches above the bottom of the enclosure 17 71 4 inches to 7 3 4 inches above the top of the lower intake vent opening 18 Make sure that the back of the solid box baffle is perpendicular to the ART 02482 bottom of the enclosure Make sure that the back of the solid box baffle is against the top of the enclosure Make sure that the solid box baffle is one inch or less 19 from the coils 10 and os condenser 11 of the refrigerator i O Make sure that the solid box baffle is the full width of the inside of the enclosure ART 02483 Installation Manual 8 Offset vertical enclosures If the enclosure depth is 24 inches or more and less than 25 inches See Art02484 Install an angled top baffle 172 between the top rear edge of the refrigerator and the inside edge of the upper exhaust vent opening Make sure that the angled top baffle is less than 1 4 inch 15 from the top of the refrigerator Make sure that the angled top baffle is no more than 45 from vertical 20 Install an inside corner baffle 173 between the outside edge of the upper exhaust vent opening and the s
52. rateur doit utiliser uniquement un syst me a prise d air ext rieur et a ventilation aspirante congu et agr par NORCOLD Toute autre m thode de ventilation pourrait lib rer des gaz d chappement a combustion mortels et ou des fum es explosives de gaz propane dans la zone habitable et ou sous le pont Frangais NORCOLD Inc Telephone 800 543 1219 P O Box 4248 Fax 734 769 2332 Sidney OH 45365 4248 Etats Unis ia R f 636901A 08 22 2014 Table des mati res Signalisation de la SECUmte riale ia Rie ea a Consignes relativessa lla s cutite siria Ii aa ie ii ire Certification t cod s resp ect li crei lai a a Consignes relatives la ventilation Dimensions importantes du r frig rateur Assemblage de l enceinte destin e au r frig rateur ie ini Installation de l a prise d alrinfeneure ere lea aa attente el Installation de la bouche d chappement sup rieure du toit cece eeereees Installation de d flecteurs pour une bouche d chappement sup rieure de toit Enceintes verticale Sherinian iaia le Aia Enceintes verticales d cal es Installation d une bouche d chappement sup rieure de paroi lat rale Installation de d flecteurs pour une bouche d chappement sup rieure de paroi lat rale Installation d un d flecteur d air facultatif Installation des panneaux d coratifs de porte mod les
53. rator Dimensions These key refrigerator dimensions are for your reference as necessary See Art02477 Refrigerator cabinet width w o trim 0 00 181 Assemble the Enclosure for the Refrigerator 1 Make sure the enclosure shelf is solid and level The enclosure shelf must be a metal or a wood panel and extend the full width and depth of the enclosure able to support the weight of the refrigerator and its contents level to maintain door alignment 2 Make sure there are no adjacent heat sources such as a furnace vent a hot water heater vent etc 6 ART 02477 Installation Manual 5 3 Make sure the enclosure is 68 94 69 06 inches high x 35 94 36 04 inches wide x 24 00 24 13 inches deep NOTICE Measure the enclosure depth 174 from the interior face of the enclosure to the inside of the rear wall See ART02478 4 If there is more than 1 2 inch between either side of the refrigerator and the inside of the enclosure Fill the space with fiberglass batt type insulation or add a baffle to eliminate the clearance The rear of the batt type insulation must be between 18 19 inches from the face of the enclosure Securely attach the batt type insulation to the enclosure so that it remains in this position during refrigerator installation if it becomes wet and in windy conditions 5 The enclosure face must be perpendicular to the enclosure shelf to provide a combustion seal
54. rect polarity terminal Connect the Low Ambient Heater Connect the low ambient heater wires to the 12 volts DC supply The black wire of the low ambient heater connects to 12V and the brown wire connects to 12V ground This kit supplies DC voltage to the heater any time the ambient temperature is low enough Extended storage during NOTICE cold weather will drain the vehicle batteries To prevent battery drain remove the 3 amp fuse from the low ambient heater Installation Manual 15 Connect the Propane Gas Components This refrigerator operates on propane gas at a pressure of 11 inches Water Column Propane The controls operate on 12 volts DC 10 5 volts min 15 4 volts max Operation out of these limits can damage the refrigerator electrical circuit parts and will void the warranty Connect the propane gas supply system Awarninc Be very careful when working on or near the propane gas system Do not smoke or use an open flame near the propane gas system Do notuse an open flame to examine for leaks Do not connect the refrigerator to the propane gas tank without a pressure regulator between them To avoid a propane gas leak always use two wrenches to tighten or loosen the propane gas supply line connections Leaking propane gas can ignite or explode and result in dangerous personal injury or death Connect the gas supply line to the refrigerator Make sure that all tubing and fittings obey all loca
55. seur du iy r frig rateur I Veiller a ce qu il y ait au plus 1 po 19 entre le d flecteur du condenseur et le condenseur Poser un d flecteur absorbeur 171 entre 21 po et 21 1 2 po au dessus du bas de l enceinte 17 7 1 4 po 7 3 4 po au dessus du haut de l ouverture de la 4 prise d air inf rieure 18 Veiller a ce qu il y ait au plus 1 po 19 entre le d flecteur absorbeur et l absorbeur Si la profondeur de l enceinte est sup rieure ou gale 26 po voir Art02483 Poser un d flecteur sup rieur 13 Veiller a ce qu il y ait moins de 1 4 po 15 entre le d flecteur sup rieur et le haut du r frig rateur Installer un d flecteur en forme de bo te pleine en bois ou en t le d aluminium ou galvanis e 21 a l arri re de l enceinte S assurer que le bas du d flecteur en forme de bo te pleine se trouve entre a 18 po et 18 1 2 po au dessus du bas de l enceinte 17 4 1 4 po 4 3 4 po ART 02482 au dessus du haut de l ouverture de la prise d air inf rieure 18 Veiller a ce que l arri re du d flecteur en forme de bo te pleine soit perpendiculaire au bas de l enceinte 13 15 Veiller a ce que l arri re du d flecteur en forme de bo te pleine soit contre le haut de l enceinte Veiller ce que le d flecteur en forme de b
56. so The DC voltage to the refrigerator is low Check That the battery charging equipment of the vehicle is operational That the AC DC converter is operational if applicable See your dealer or authorized Norcold Service Center Sp Audible alarm also This is a fault within the refrigerator controls Turn the refrigerator power OFF and then back on to reset If the Fault Code continues see your dealer or authorized Norcold Service Center Temperature setting flash es when TEMP SET or MODE button is pushed The refrigerator is operating on the Backup Operating System This is not owner serviceable See your dealer or authorized Norcold Service Center AC TE Audible alarm also This is a fault within the refrigerator controls This is not owner serviceable See your dealer or authorized Norcold Service Center AC HE Audible alarm also This is problem related to the AC heater This is not owner serviceable See your dealer or authorized Norcold Service Center oP LI Audible alarm also A temperature limit switch is open This is not owner serviceable See your dealer or authorized Norcold Service Center EL o Audible alarm also A flame is present at the burner when there should be none This is not owner serviceable See your dealer or authorized Norcold Service Center Installation Manual 20 Installat
57. st vent Install an aluminum or galvanized steel bent sheet condenser baffle 26 Make sure that the bend of the condenser baffle is the full width of the inside of the enclosure Make sure that the bend of the condenser baffle is flush with the bottom edge of the door frame of the upper side wall exhaust vent Make sure that the top edge of the condenser baffle is 1 4 inch or less 15 from the lower rear corner of the condenser If the enclosure depth is 26 inches or more See Art02489 Install a wood aluminum or galvanized steel top baffle 13 between the top of the refrigerator and the top of the upper exhaust vent 24 Make sure that the top baffle is less than 1 4 inch 15 from the top of the refrigerator and that the baffle overlaps the refrigerator 1 inch or less Make sure that the baffle is against the wall of the vehicle at the top of the upper exhaust vent and less than 1 4 inch 15 above the opening for the upper exhaust vent Install a solid box baffle 21 between the lower intake vent and the upper exhaust vent Make the solid box baffle either from wood or from an aluminum or galvanized steel sheet Make sure that the bottom of the solid box baffle is 21 inches to 21 1 2 inches above the bottom of the enclosure 17 7 1 4 inches to 7 3 4 inches above the top of the lower intake vent opening REF 18 Make sure that the back of the solid box baffle is perpendicular to the bottom
58. t le maintenir enfonc pour faire d filer l un apr s l autre les modes de fonctionnement disponibles du r frig rateur Lorsque l indicateur de mode d sir s allume sur l cran cristaux liquides rel cher le bouton MODE Sinon appuyer sur le bouton MODE et le rel cher de mani re r p t e pour changer un par un les modes de fonctionnement disponibles du r frig rateur mesure que le mode est chang l indicateur de mode concern s allume ART 02492 Manuel d installation 18 3 Sur les mod les double alimentation les indicateurs de mode sont les suivants voir Art02493 Mode Auto courant lectrique c a 281 Mode Auto gaz 282 Mode Manuel courant lectrique c a 283 Mode Manuel gaz 284 S lectionner le r glage de temp rature Appuyer sur le bouton REGLAGE TEMPERATURE 32 et le maintenir enfonc pour faire d filer l un apr s l autre les r glages de temp rature voir Art02492 EB Sinon appuyer sur le bouton REGLAGE TEMPERATURE et le relacher de mani re r p t e pour changer un par un les r glages de temp rature Les r glages de temp rature 278 s inscrivent sous forme de chiffres sur l cran cristaux liquides S lectionner l un des neuf 9 r glages de temp rature Un 1 correspond la temp rature la plus lev e Neuf 9 correspond la temp rature la plus basse V rification de la soupap
59. the angled top baffle is less than 1 4 inch from the top of the refrigerator Make sure that the angled top baffle is no more than 45 from vertical 20 Install an inside corner baffle 173 between the outside edge of the upper exhaust vent opening and the solid box baffle Make sure that the inside corner baffle is approximately parallel to the angled top baffle Install a wood or an aluminum or galvanized sheet solid box baffle 21 in the rear of the enclosure Make sure that the bottom of the solid box baffle is 21 inches to 21 1 2 inches above the bottom of the enclosure 17 7 1 4 inches to 7 3 4 inches above the top of the lower intake vent opening 18 Make sure that the back of the solid box baffle is perpendicular to the bottom of the enclosure Make sure that the back of the solid box baffle is either against the top of the enclosure or against the inside corner baffle 173 depending on the vehicle design Make sure that the solid box baffle is one inch or less from the coils 10 and condenser 11 of the refrigerator ART 02486 Make sure that the solid box baffle is the full width of the inside of the enclosure Install an Upper Side Wall Exhaust Vent If the design of the vehicle does not allow you to install a roof exhaust vent install an upper side wall exhaust vent _ 22 gt The refrigerator is 23 75 in min to 24 05 in max from the rear of the breaker My e
60. tifs Les panneaux d coratifs doivent tre d une paisseur EN maximum de 3 16 po Installer les panneaux d coratifs de porte sur les portes du r frig rateur avant d installer le r frig rateur dans le v hicule 1 Faire deux panneaux de porte sup rieurs de 17 1 4 po de largeur et 23 1 8 po de hauteur Les panneaux en relief doivent tre centr s sur chaque porte et 38 leurs dimensions ne doivent pas d passer 16 1 2 po de largeur et 22 3 8 po de hauteur 39 2 Faire deux panneaux de porte inf rieurs de 17 1 4 po de largeur et 42 5 16 po de hauteur Les panneaux en relief doivent tre centr s sur chaque porte et leurs dimensions ne doivent pas d passer 16 1 2 po de largeur et Let 41 9 16 po de hauteur 3 Installer les panneaux d coratifs de porte Tirer sur le dispositif de retenue 37 du panneau pour le s parer de chaque porte 39 voir Art01804 Art01804 Pousser un panneau d coratif de porte 38 dans les fentes de chaque porte Manuel d installation 12 S assurer que chaque dispositif de retenue du panneau est positionn correctement et pousser les attaches incurv es 125 du dispositif de retenue du panneau 37 l int rieur des attaches incurv es 126 de la porte voir Art01805 Art01805 Installation du r frig rateur La meilleure m thode pour manutentionner manuellement la main ou m canique
61. uite de gaz propane toujours se servir de deux cl s pour serrer ou desserrer les raccords du tuyau d arriv e de gaz propane Le gaz propane qui s chappe risque de s enflammer ou d exploser d o risque de blessures graves ou mortelles Brancher le tuyau d arriv e de gaz au r frig rateur S assurer que tous les tuyaux et raccords respectent les codes locaux provinciaux et f d raux s appliquant leurs types et dimensions S assurer que tous les raccords m talliques souples sont conformes la Norme actuelle CAN1 6 10 S assurer que les mat riaux utilis s pour le tuyau d arriv e de gaz respectent la fois les normes actuelles ANSI A 119 2 NFPA 1192 et ACNOR Z240 pour les v hicules de loisir Norcold recommande l utilisation d un tube en cuivre de 3 8 po comme tuyau d arriv e de gaz et requiert un raccord m le conique de 3 8 po SAE UNF 5 8 18 comme connexion avec le r frig rateur Faire remonter le tuyau d arriv e de gaz propane par le plancher de l enceinte Veiller ce que le trou travers le plancher soit suffisamment grand pour permettre un d gagement suffisant pour le tuyau d arriv e de gaz Placer un joint r sistant aux intemp ries oeillet mat riau d tanch it etc autour du tuyau d arriv e de gaz l ou il traverse le plancher afin d viter toute vibration et abrasion Pour viter les vibrations et le frottement veiller ce que le tuyau d arriv e de ga
62. up rieur et le haut du r frig rateur S assurer que le d flecteur inclin sup rieur n est pas plus de 45 de la verticale 20 ART 02484 Poser un d flecteur d angle int rieur 173 entre le bord ext rieur de louverture de la bouche d chappement sup rieure et la paroi lat rale du v hicule S assurer que le d flecteur d angle int rieur est peu pr s parall le au d flecteur inclin sup rieur Poser un d flecteur de condenseur 16 au bord le plus bas du condenseur du r frig rateur Veiller ce qu il y ait au plus 1 po 19 entre le d flecteur du condenseur et le condenseur Poser un d flecteur absorbeur 171 entre 21 po et 21 1 2 po au dessus du bas de l enceinte 17 7 1 4 po 7 3 4 po au dessus du haut de l ouverture de la prise d air inf rieure 18 Veiller ce qu il y ait au plus 1 po 19 entre le d flecteur absorbeur et l absorbeur ART 02485 9 Manuel d installation Si la profondeur de l enceinte est sup rieure ou gale 26 po voir Art02486 Poser un d flecteur inclin sup rieur 172 entre le bord sup rieur arri re du r frig rateur et le bord int rieur de louverture de la bouche d chappement sup rieure Veiller ce qu il y ait moins de 1 4 po entre le d flecteur inclin sup rieur et le haut du r frig rateur S assurer que le d flecteur inclin sup rieur n est pas a plus de 45 de la verticale 20 Poser un d
63. utilisation du r frig rateur sans masse appropri e peut causer des chocs lectriques dangereux ou la mort en cas de contact avec les parties m talliques du r frig rateur Raccordement de l alimentation en courant alternatif 120V Brancher le cordon d alimentation C A dans une prise triphas e avec mise la terre uniquement Ne pas enlever la broche ronde de mise la terre de l un ou de l autre des cordons d alimentation Ne pas utiliser d adapteur deux broches ni de rallonge lectrique avec l un ou l autre des cordons d alimentation en courant alternatif L utilisation d un r frig rateur incorrectement mis la terre peut causer un choc lectrique voire la mort lorsqu on touche les parties m talliques de l appareil Brancher le s cordon s d alimentation C A dans une prise triphas e avec mise la terre S assurer que la prise est d un acc s facile a partir de la prise d air inf rieure S assurer que le s cordon s d alimentation n entre nt pas en contact avec le couvercle du brdleur le conduit de sortie des fum es ou tout autre l ment chaud qui pourrait endommager la gaine isolante du cordon Raccordement de l alimentation en courant continu 12V Le calibre du fil et du fusible a utiliser augmentent avec la distance entre la batterie du v hicule et le r frig rateur Une chute de tension se produira si la section du fil est trop faible pour la distance La chute de te
64. y system x ilari AA oe a dee aon SAAS ea ea dn aa 16 Examine the propane gas supply system for leakS i ie 16 Connect the Ce Maker yagi sivse scene edt o ea 17 Gonnectthe water supply line rres ia ai aaa iaia 17 Ignition and Start Up iaia ii at 18 ignition and starntupz ia it te et D ae 18 Modes ofroperationi assai rari aTa Steet angst aa ea aA a Ee rente Seine 18 Do a test of the gas safety Valve iii RO i ini 19 SNU TOW esie p te ee AO III II Pars EE Le 19 Fault Codes surtt ins dames aci han gage end hu dieuti dis Ai a 20 Safety Awareness Read this manual carefully and understand the contents before you install the refrigerator Be aware of possible safety hazards when you see the safety alert symbol on the refrigerator and in this manual A signal word follows the safety alert symbol and identifies the danger of the hazard Carefully read the descriptions of these signal words to fully know their meanings They are for your safety This signal word means a hazard which if ignored can cause dangerous personal injury death or much property damage Acaution This signal word means a hazard which if ignored can cause small personal injury or much property damage Installation Manual 2 Safety Instructions This refrigerator is not approved for use as a free standing refrigerator It is equipped for the use of propane gas only and can not be changed to use any other fuels natura
65. z ne touche rien dans l enceinte Brancher le tuyau d arriv e de gaz au raccord du r frig rateur Manuel d installation 16 Rechercher les fuites dans le tuyau d arriv e de gaz propane Ne pas laisser la solution de d tection des fuites entrer en contact avec les composants lectriques Nombre de liquides sont conducteurs et peuvent poser des risques de court circuit voire m me d incendie Employer une solution de d tection des fuites pour v rifier l tanch it du tuyau d arriv e de gaz et de tous les raccords de gaz propane Si vous utilisez de l air comprim pour le test La pression de l air comprim au niveau du robinet d arr t manuel du r frig rateur ne doit pas d passer 1 2 psig colonne d eau de 14 po Si la pression de l air comprim est sup rieure a 1 2 psig colonne d eau de 14 po retirer le tuyau d arriv e de gaz du raccord du r frig rateur avant le test Si la pression de l air comprim est gale ou inf rieure a 1 2 psig colonne d eau de 14 po fermer le robinet d arr t manuel du r frig rateur avant le test Raccordement de la machine glagons En option La machine gla ons est mont e dans les r frig rateurs l usine L installateur du r frig rateur devra raccorder un tuyau d arriv e d eau froide l lectrorobinet situ l arri re du r frig rateur Ce qui suit est n cessaire pour le raccordement de la machine gla ons