1. Error Bookmark not defined READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES 19 221547 IMPORTANT SAFETY INSTRUCTIONS PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION AWARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY OBSERVE THE FOLLOWING 1 Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards including fire rated construction 2 When cutting or drilling into wall or ceiling be careful not to damage electrical wiring or other hidden utilities 3 Ducted fans must be vented to the outside a Before servicing or cleaning unit open the light panel and SWITCH POWER OFF AT SERVICE PANEL b Clean all grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust air into wall spaces attics crawl spaces or garages NOTE This warranty is void without an authorized agent s receipt or if unit is damaged due to misuse poor installation improper use mistreatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void th
2. N 24 Duct Cover Mounting Bracket 7 7 PARTS LIST MODEL NO CH2230SQB 22365 NO DESCRIPTION MODEL SIZE PART NO 1 Multi Duct Exhaust C1 0507 1530 2 Vent Cover Top B101 1530 12 3 Vent Cover Rear C1 0508 1530 A 4 Vent Cover Frame C1 0508 1530 B 5 Hood Casing CH2230SQB 10 1630A CH2236SQB 10 1636A 6 Halogen Light 12V 20W Max C1 0403 0101 7 Control Unit C1 0501 0101 8 Control Board C1 0404 4001 A 9 Control Panel Support C1 0207 5200 10 Transformer Support C1 0201 1530 11 Transformer Motor C1 0402 A120 08 12 Air Chamber A Air Chamber Top CH2230SQB B Air Chamber Side CH2230SQB A Air Chamber Top CH2236SQB B Air Chamber Side CH2236SQB CH2230SQB 13 Transformer Light CH2236SQB C1 0402 0120 40 14 Capacitor C1 0401 0120 01 15 Processor Board Box C1 0501 0102 16 Processor Board C1 0404 4110 B 17 Motor Right 18 Motor Left 19 Turbine Impeller Right C1 0251 0880 B 20 Turbine Impeller Left C1 0251 0880 A 21 Oil Tunnel Seal C1 0502 0301 22 Oil Tunnel C1 0502 0102 23 Impeller Plastic Cover C1 0251 0001 24 Safety Screen C1 0602 0101 25 Baffle Filter 26 Bottom Casing CH2230SQB Optional Duct Cover NO DESCRIPTION MODEL SIZE PART NO 01 Hood Mounting Bracket C1 0221 1530 02 Screws TS 4 x 8 mm C1 0708 0006 03 Duct Cover CH1120DC 12 15300 51 04 Duct Cove
3. 81 Cableado Hacia la Fuente de Alimentaci n ADVERTENCIA DE SEGURIDAD RIESGO DE ELECTROCUCI N ESTA CAMPANA DE EXTRACCI N DEBE TENER UNA CONEXION A TIERRA ADECUADA ASEGURESE QUE ESTO SEA REALIZADO POR UN ELECTRICISTA ESPECIALIZADO DE ACUERDO CON TODOS LOS C DIGOS ELECTRICOS APLICABLES NACIONALES Y LOCALES ANTES DE CONECTAR LOS CABLES DESCONECTE EL SUMINISTRO EL CTRICO EN EL PANEL DE SERVICIO Y CIERRE EL PANEL DE SERVICIO PARA PREVENIR QUE LA UNIDAD SE ENCIENDA ACCIDENTALMENTE Conecte los cables el ctricos Conecte tres cables negro blanco y verde con los cables de la casa y tape con conectores de cables Con ctelos seg n su color negro con negro blanco con blanco y verde con verde seg n se muestra en la Figura 6 Si necesitara ocultar las conexiones del cableado el ctrico empuje los cables hacia dentro de la caja del cableado Accese a las conexiones de cables debajo de la campana Aseg rese que los cables no se resbalen entre el motor o cualquier pieza que se mueva para prevenir que se da en Ensamblado Final 1 Coloque los filtros deflectores debajo de la campana Consulte la Figura 30 Figura 30 82 INSTRUCCIONES DE OPERACI N Esta campana KOBE est equipada con cuatro controles electr nicos con un encendido en espera de 10 segundos y una desactivaci n luego de 30 segundos de retraso dos poderosos impulsores de turbina centrifuga con pantallas de seguridad focos brillantes de hal gen
4. MESURES DE S CURIT IMPORTANTES SVP LIRE CETTE SECTION ATTENTIVEMENT AVANT L INSTALLATION AVERTISSEMENT AFIN DE R DUIRE LES RISQUES D INCENDIE DE CHOC LECTRIQUE ET DE BLESSURES RESPECTER LES CONSIGNES SUIVANTES 1 L installation et le c blage lectrique doivent tre effectu s par des techniciens qualifi s et en conformit avec tous les codes et toutes les normes qui s appliquent m me pour les constructions ignifug es 2 Lorsque vous d coupez ou percez un mur ou un plafond prendre soin de ne pas endommager le filage lectrique ou autres conduits cach s 3 Les hottes vacuation doivent tre vacu es l ext rieur a Avant une r paration un entretien pr ventif ou un nettoyage ouvrir le panneau de la lumi re et COUPER LE COURANT LECTRIQUE SUR LE TABLEAU DE DISTRIBUTION Nettoyer le ventilateur le filtre optionnel et les surfaces charg es de graisse fr quemment Afin de r duire les risques d incendie et afin de disperser l air ad quatement vacuer l air l ext rieur NE PAS ventiler l air d vacuation dans les murs les greniers les vides sanitaires ou les garages o 7 NOTE La garantie de appareil sera nulle sans le recu d un distributeur autoris de KOBE ou si l appareil est endommag par une utilisation inad quate une installation d ficiente un usage inappropri un mauvais traitement de la n gligence ou par toute autre circonstance chappant au contr
5. 13 Transformateur lumi re CH2236SQB C1 0402 0120 40 14 Condensateur C1 0401 0120 01 15 Bo tier du processeur C1 0501 0102 16 Processeur C1 0404 4110 B 17 Moteur droit 18 Moteur gauche 19 Pale de turbine droite C1 0251 0880 B 20 Pale de turbine gauche C1 0251 0880 A 21 Couvercles de r cup rateur de graisse C1 0502 0301 22 R cup rateur de graisse C1 0502 0102 23 Capuchon en plastique de pale de turbine C1 0251 0001 24 Grilles de s ret C1 0602 0101 25 Filtre d flecteur 26 Panneau pare claboussures CH2230SQB Couvre conduit optionnel N DESCRIPTION MODELE FORMAT N DE PI CE 01 Support de fixation de la hotte C1 0221 1530 02 Vis TS 4 x 8mm C1 0708 0006 03 Couvre conduit CH1120DC 12 15300 51 04 Support de fixation pour couvre conduit C1 0221 1530 05 Vis 3 16 po x 3 8 po C1 0707 0001 06 Socle de caoutchouc C1 0511 0382 07 Vis TS 4 x 8 mm C1 0708 0006 57 CH2230SQB CH2236SQB N de modeles COUVRE CONDUIT o e N N O CH2230SQB DIAGRAMME DES CIRCUITS CH2230SQB 22365 N de modeles 120V AC GROUND SUPPLY NEUTRAL H BLANC CONDENSATEUR 3 5 3 5uF 250V AC ae ri BLEU JAUNE VERT BLEU IN TRANSFORMATEUR MOTOR BLANC BLEU BLANC BLEU BRUN NOIR BRUN ROUGE ORANGE 59 JAUNE VERT BLEU TROUBLE SHOOTING Probl me Cause probable Solution
6. Utilice cinta de aislar para sellar las uniones entre las secciones del tubo Si fuera necesario prepare un marco posterior en la pared con madera de entramado para una instalaci n segura Utilizando las referencias de la Tabla 2 y las medidas en la P ginas 84 85 decida el nivel de la madera Consulte la Figura 14 Preparaci n de la Campana antes de la Instalaci n Conecte la campana temporalmente para probar su operaci n antes de instalar Retire la pel cula protectora de la campana y de la cubierta de conductos si hubiera alguna Corte el escape de multi conductos de ventilaci n de acuerdo al tama o del tubo de ventilaci n Consulte la Figura 15 TAPA DEL TECHO ENTRAMADO DE LA PARED Rendija de Ventilaci n Rendija de Ventilaci n Rendija de Ventilaci n Redonda de 6 Redonda de 7 de 3 1 4 x 10 Figura 15 76 Si fuera necesario coloque dos bases de goma incluidas con dos tornillos 4x8 mm incluidos en la parte posterior de la campana Coloque el soporte de montaje de la campana en la parte posterior de la misma con nueve tornillos 3 16 x 3 8 incluidos como se muestra en la Figura 16 Instalaci n de la Campana PRECAUCI N Si fuera necesario mover la estufa para instalar la campana desconecte la electricidad en la caja el ctrica principal si es una estufa el ctrica APAGUE EL GAS ANTES DE MOVER UNA ESTUFA DE GAS 1 Utilizando las referencias en la Tabla 2 y las medidas en las P ginas 84
7. 29 3 4 x 22 x 5 7 8 223650 35 3 4 x 22 x 5 7 8 1 Cubierta de Conductos Ajustable de Dos Piezas CH1120DC 11 3 4 x 10 1 4 x 20 5 8 39 3 4 2 Panel Posterior de Acero Inoxidable de 30 SSP30 30 x 1 10 x 32 3 Panel Posterior de Acero Inoxidable de 36 SSP36 36 x 1 10 x 32 Net Gross CH2230SQB CH2236SQB QuietMode Bajo Medio Alto 300 450 600 720 1 2 3 0 4 5 4 8 Las especificaciones est n sujetas a cambio sin previo aviso 86 MEDIDAS Y DIAGRAMAS Todas las medidas en pulgadas han sido convertidas de mil metros Las medidas en pulgadas son medidas aproximadas Todas las medidas est n en mil metros PARA DEBAJO DEL GABINETE 30 Agujeros preperforados A 36 42 48 Agujeros preperforados A y B PARA INSTALACI N INDEPENDIENTE CON CUBIERTA DE CONDUCTOS OPCIONAL 7 oN 0 7 46 e Ki Av 55 9 1 8 230 48 7 8 1240 MAX 29 3 4 755 87 Soporte de Montaje de la Campana Soporte de Montaje de la Cubierta de Conductos 10 254 8 3 16 208 48 1 6 OLL BEE 7 1 2 190 08 2 5 8 67 5 88 LISTADO DE PIEZAS MODELO NO CH2230SQB 22365 NO DESCRIPTION MODELO TAMANO PIEZA NO 1 Escape de M
8. QuietMode Photo 31 MISE EN MARCHE e Presser une fois sur le bouton marche arr t Note Si aucun des autres boutons n est enfonc en dedans de 10 secondes la hotte se fermera automatiquement e La hotte d marre a basse vitesse Chaque fois que la commande de vitesses est enfonc e le cycle passe la vitesse suivante e Presser sur le bouton de commande de vitesses A pour enclencher le cycle bas moyen lev ou QuietMode e Presser sur le bouton de commande de vitesses B pour enclencher le cycle bas QuietMode lev ou moyen Note Les commandes de vitesses A ou B mettront en marche les deux ventilateurs Ces deux boutons de vitesses vous permettront cependant de changer de vitesse plus rapidement e Presser sur le bouton de commande des lampes pour allumer les lampes halog nes ARR T e Presser une fois sur le bouton marche arr t les lampes vont clignoter et le courant sera coup entierement apr s 30 secondes OU e Presser deux fois sur le bouton marche arr t le courant se coupera imm diatement Si seules les lampes sont allum es en pressant une fois sur le bouton marche arr t le courant se fermera apr s 30 secondes 51 ENTRETIEN NETTOYAGE Pour favoriser un rendement optimal nettoyer r guli rement les surfaces de la hotte et les filtres d flecteurs Nettoyage Des Surfaces De La Hotte AVERTISSEMENT NE JAMAIS EMPLOYER DE NETTOYANTS OU LINGES ABRASIFS OU EN
9. access to perform repairs During the two year Limited Warranty period additional charges may apply which include but are not limited to e Service technician travel charges if the requested service location is 30 miles out of KOBE s authorized service area e Parts shipping expenses e Un installation of defective product and Installation of replacement product ONE YEAR LIMITED WARRANTY FOR PARTS ON KOBE BRILLIA SERIES For one year from the date of your original invoice from a KOBE authorized dealer we will provide free of charge parts to replace those that failed due to manufacturing defects lt is our sole discretion to choose to repair or replace defective parts It is your sole responsibility for all labor costs associated with this warranty Warranty Exclusions This warranty does not cover including but not limited to the following Improper installation Any repair alteration modification not authorized by KOBE Duct alteration modification and connection Incorrect electric current voltage or wiring Normal maintenance and service required for the product Consumable parts such as light bulbs and carbon filters Improper usage of the product that it is not intended for such as commercial use outdoor use and multi family use Normal wear and tear Chips scratches or dents by abuse or misuse of the product Damages caused by accident fire flood and other Acts of God Expenses incurred for service located outsid
10. nosotros o nosotros le garantiza al comprador original referido aqu como usted o su todos los productos fabricados o suministrados por nosotros para estar libres de defectos de fabricaci n y materiales como sigue DOS ANOS DE GARANT A LIMITADA DE LAS PIEZAS Y MANO DE OBRA DE SERIE KOBE PREMIUM Durante dos afios a partir de la fecha de la factura original de un distribuidor autorizado de KOBE nosotros a nuestra sola discreci n optamos por reparar o reemplazar el producto sin cargo que ha fallado debido a defectos de fabricaci n Solo es su responsabilidad asegurar que el producto es de f cil acceso para el t cnico de servicio que realice las reparaciones El t cnico de servicio no ser en ning n caso eliminar alterar o modificar cualquier artefacto construido alrededor y o conectado al producto para obtener acceso para realizar reparaciones Durante el per odo de garant a limitada de dos a os pueden aplicar cargos adicionales que incluyen pero no se limitan a o Cargos de viaje si el t cnico de servicio si la ubicaci n del servicio requerido es de 30 kil metros fuera de la zona de servicio autorizada KOBE o Piezas gastos de env o o Desinstalaci n del producto defectuoso e instalaci n de productos de sustituci n UN ANO DE GARANT A LIMITADA PARA PIEZAS DE KOBE SERIES BRILLIA Durante un afio a partir de la fecha de la factura original de un distribuidor autorizado de KOBE nos proporcionar sin cos
11. plaque de sortie int rieure arri re Voir Photo 23 D couper l ouverture multi conduit selon la taille des tuyaux d chappement R f rez vous la Photo 24 Poteaux de cloison Conduits Photo 21 Photo 22 47 Couvercle int rieur arr re c EEG Couvercle invers arri re Photo 23 Photo 24 n cessaire fixer les deux fixations fournis en caoutchouc en compagnie des deux vis 4x8 mm fournies l arri re de la hotte Fixer le support de montage au dos de la hotte avec l aide des neuf 3 16po x 3 8po vis fournies tel qu indiqu la Photo 25 Installation de la hotte AVERTISSEMENT S il faut d placer une cuisiniere lectrique pour installer la hotte couper d abord l alimentation lectrique cette cuisini re par le tableau de distribution principal COUPER LE GAZ AVANT DE DEPLACER UNE CUISINIERE A GAZ 1 En utilisant en r f rence la Table 2 et les mesures la Page 53 54 rep rez le point de nivellement de la hotte Installer deux vis de fixation non fournies sur le mur laissant 1 8po d espace par rapport au mur comme indiqu la Photo 26 Vis de montage 2 Photo 25 Photo 26 2 Utiliser un tuyau d aluminium ou d acier pour raccorder l ouverture de sortie l arri re de la hotte au conduit Utiliser du ruban adh sif entoil d aluminium pour rendre tous les raccords s curitaires et herm tiques 3 Aligner le support de montage avec les deux vis sur
12. re TOUFFER LES FLAMMES l aide d un couvercle herm tique une plaque biscuits ou un plateau m tallique puis fermer le rond ou le br leur GARDER LES MATERIAUX INFLAMMABLES OU COMBUSTIBLES LOIN DES FLAMMES Si les flammes ne s teignent pas imm diatement VACUER LA ZONE ET APPELER LE SERVICE D INCENDIE ou le 911 NE JAMAIS SOULEVER UNE CASSEROLE EN FEU Il y a risque de br lure e PAS UTILISER D EAU incluant serviettes ou linges vaisselle mouill s cela provoquerait un violent jet de vapeur e Utiliser un extincteur SEULEMENT si a vous poss dez un extincteur de classe ou C et si vous savez vous en servir b le feu est petit et est contenu dans la zone de d part C vous avez appel le service d incendie d vous pouvez combattre le feu le dos pr s d une sortie Que faire si une odeur de gaz se d gage Eteindre toute flamme nue pas essayer d allumer des lumi res ou tout type d appareil lectrom nager Ouvrir toutes les portes et fen tres afin de chasser le gaz Si une odeur de gaz est toujours perceptible appeler votre fournisseur de gaz ainsi que le service d incendie imm diatement ATTENTION 1 Cette hotte doit tre utilis e uniquement pour une ventilation normale Ne pas s en servir pour vacuer des substances et vapeurs dangereuses ou explosives Afin de r duire les risques d incendie employer seulement des conduits de m tal Il doit y avoir suffisamm
13. transformador de la luz De ser necesario reemplace el transformador de la luz El panel de control o la placa de procesador est n defectuosos Reemplace el panel de control o la placa de procesador La campana de extracci n no est ventilando correctamente La campana de extracci n no se encuentra instalada en el espacio recomendando por el fabricante Ajuste el espacio entre la campana y la parte superior de la estufa a 27 a 30 Para la campana de cocina de isla el espacio entre la campana y la parte superior de la estufa deber ser de 30 a 36 No hay aire de reposici n en la casa Abra la ventana para optimizar el rendimiento de la campana de extracci n creando suficiente aire de reposici n Una obstrucci n bloquea la red de conductos Remueva todas las obstrucciones de la red de conductos El tama o del tubo es m s peque o que el tubo recomendado Cambie los tubos de acuerdo con la recomendaci n del fabricante Aire fr o entra en la casa La conexi n de los conductos no est sellada correctamente Verifique la instalaci n de los tubos El regulador no est instalado adecuadamente o no ha sido instalado Verifique la instalaci n del regulador El regulador no est instalado Instalar el regulador le ayudar a eliminar el reflujo de aire 92 GARANTIA CERTIFICADO DE GARANTIA KOBE Range Hoods denominados aqu como
14. 289 5623 Email info koberangehoods com Your notes 31 Fran ais LISEZ CECI AVANT L INSTALLATION 1 V rifiez soigneusement tous les contenus des emballages 2 Inspectez soigneusement l appareil pour tous dommages ou d fauts cosm tiques 3 Tester l appareil avant l installation 4 Engagez un entrepreneur lectricien certifi pour proc der l installation EN CAS DE PROBLEME 1 NINSTALLEZ PAS L APPAREIL ET CONSERVER LE CONTENU DE L EMBALLAGE D ORIGINE 2 Ayez votre preuve d achat originale et le num ro de s rie du produit 3 Appelez au 1 877 BU Y KOBE 289 5623 ou contactez nous par courriel info koberangehoods com pour signaler le probl me 33 FRENCH LIRE ET CONSERVER CES INSTRUCTIONS TABLE DES MATI RES MESURES DE S CURIT IMPORTANTES eret 35 CONTENU DE LA BOITE 37 INSTALLATION cueca dd daa 37 MODE iaa 51 ENTRETIEN NETTOYAGE ana ae 52 SEEGIFICATIONS oct eom Sade tinta aa aa ai arta Sara Bata e dc aa 54 MESURES et DIAGRAMMES 55 LISTE DES PI CES aaa aaa aaa aaa aa ae aaa aaa ae 57 DIAGRAMME DES CIRCUITS e IDEE 59 TROUBLE SHOOTING EN 60 NE AX 61 ENREGISTREMENT DU PRODUIT anna aaa aaa aaa ae 63 LIRE ATTENTIVEMENT TOUTES LES CONSIGNES AVANT DE COMMENCER TOUT LE C BLAGE ELECTRIQUE DOIT ETRE EFFECTUE PAR UN PROFESSIONNEL EN CONFORMITE AVEC LES CODES D ELECTRICITE LOCAUX ET NATIONAUX US 221547 34
15. 85 marque el punto de nivel de la campana Posicione dos tornillos de montaje no incluidos en la pared dejando un espacio de 1 8 lejos de la pared como se muestra en la Figura 17 Tornillos de montaje y Figura 16 Figura 17 2 Alinee el soporte de montaje de la campana con los dos tornillos en la pared y eng nchela en su lugar Apriete los tornillos para asegurar la campana a la pared PRECAUCION ASEGURESE QUE LA CAMPANA ESTE FIJA ANTES DE SOLTARLA 77 3 Instalaci n de la Cubierta de Conductos Marque la posici n del soporte de montaje de la cubierta de conductos Utilice la referencia E de la Tabla 2 y las medidas en las Paginas 84 85 Coloque y fije el soporte de montaje de la cubierta de conductos con dos tornillos no incluidos Consulte la Figura 18 NOTA La cubierta interna de conductos cubrir el soporte de montaje de la cubierta de conductos Utilice un tubo de aluminio o acero para conectar el escape pl stico en la campana a la red de conductos de arriba Utilice cinta de aislar para hacer que las uniones queden seguras y herm ticas Conecte los cables el ctricos Consulte el Cableado a la Fuente de Alimentaci n en la P gina 79 Deslice la cubierta interna de conductos hasta 2 pulgadas antes de deslizar completamente la cubierta de conductos en la campana Consulte la Figura 19 Figura 18 Figura 19 Ajuste el alto de la cubierta interna de conductos al soporte de montaje de la cubierta de con
16. a Class A B C extinguisher and know how to operate it b The fire is small and contained in the area where it started C The fire department has been called d You can fight the fire with your back to an exit What to Do If You Smell Gas Extinguish any open flame Do not try to turn on the lights or any type of appliance Open all doors and windows to disperse the gas If you still smell gas call the Gas Company and Fire Department right away ACAUTION 7 For general ventilation use only Do use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and code authorities Activating any switch on may cause ignition or an explosion 5 Due to the size and weight of this hood installation by 2 persons is recommended WARNING ELECTRICAL SHOCK HAZARD Can result in serious injury or death Disconnect appliance from electric power before servicing If equipped the fluorescent light bulb contains small amounts of mercury which must be recycled or disposed of according to Local State
17. cabinets 5 Ins rer les vis non fournies exactement au centre de chaque trou de d cochage Assurez vous que toutes les vis sont en place avant de les resserrer AVERTISSEMENT ASSUREZ VOUS QUE LA HOTTE EST SOLIDEMENT FIXEE EN PLACE AVANT DE RELACHER L APPAREIL Trou 1po de diam tre Photo 12 Raccordement aux conduits 6 Utiliser des tuyaux d aluminium ou d acier pour relier le joint de raccordement en plastique de la hotte aux conduits dessus Utiliser du ruban adh sif d aluminium pour sceller les joints s rs et ainsi obtenir une parfaite tanch it 43 INSTALLATION SOUS UN LOT CONDUIT SUP RIEUR Cette installation est possible uniquement avec l achat d un couvre conduit en option Pr paration avant Installation NOTE AFIN D EVITER QUE VOTRE HOTTE NE SUBISSE DES DOMMAGES ASSUREZ VOUS QUE L OUVERTURE N EST PAS BLOQU E ET EMP CHER QUE DES D BRIS NE PEN TRE DANS L OUVERTURE DES CONDUITS D terminer l emplacement du conduit d a ration de la hotte vers l ext rieur R f rez vous la Photo 13 Une canalisation droite courte et dirig e permettra la hotte de s ex cuter plus efficacement Lorsque possible diminuer le nombre de transitions coudes et longueurs Les changements de direction affecteront la performance de votre hotte Utiliser un ruban adh sif Duct tape en toile pour sceller tous les joints et ainsi assurer une parfaite tanch it Si n cessaire pr parez le mur ar
18. cocina adecuados para el tipo y cantidad de alimentos que prepara Utilice esta unidad nicamente de la manera en que fue dise ada por el fabricante Antes de darle servicio desconecte el suministro el ctrico en el panel de servicio y cierre bajo llave el panel de servicio de ser posible para prevenir que la unidad se encienda accidentalmente Limpie el ventilador con frecuencia 67 Qu Hacer en Caso de Un Incendio Causado por la Grasa Acumulada en las Hornillas de la Estufa SOFOQUE LAS LLAMAS con una tapadera una bandeja para hornear galletas o una bandeja de metal que quede bien ajustada y luego apague la hornilla MANTENGA TODO EL MATERIAL INFLAMABLE O COMBUSTIBLE LEJOS DE LAS LLAMAS Si las llamas no se apagan inmediatamente EVACUE EL REA Y LLAME AL DEPARTAMENTO DE BOMBEROS o al 911 NUNCA LEVANTE UN SART N QUE SE EST QUEMANDO Usted Podr a Quemarse NO UTILICE AGUA incluyendo pa os o toallas mojadas esto resultar en una explosi n violenta de vapor Utilice un extinguidor SOLO si a Cuenta con un extinguidor Clase A B C y sabe c mo utilizarlo b El incendio es peque o y se ha contenido en el rea en donde comenz c Ha llamado al departamento de bomberos d Puede combatir el incendio con su espalda dirigida hacia una salida Qu Hacer si Siente Olor a Gas Apague cualquier llama abierta No intente encender las luces o cualquier otro tipo de aparato Abra todas las puertas y ventanas para dispe
19. conducto de ventilaci n de la campana hacia el exterior Consulte la Figura 1 Un ducto de escape recto y corto permitir que la campana trabaje con m s eficiencia Intente evitar tantas conexiones codos y ductos largos como sea posible Esto podr a reducir el rendimiento de la campana Antes de instalar conecte temporalmente la campana para verificar que funcione adecuadamente Retire la pel cula protectora de la campana si hay alguna Para instalar debajo del gabinete con la parte inferior empotrada coloque tiras para rellenar madera de 4 pulgadas de ancho no incluidas de cada lado Consulte la Figura 2 Mida y cree una abertura de acceso para los cables el ctricos debajo del gabinete Corte el escape de multi conductos de acuerdo al tama o de la pipa de ventilaci n Consulte la Figura 3 TAPA DEL TECHO Figura 2 Rendija de Ventilaci n Rendija de Ventilaci n Rendija de Ventilaci n Redonda de 6 Redonda de 7 de 3 1 4 x 10 Figura 3 72 Instalaci n de la Campana PRECAUCI N Si fuera necesario mover la estufa para instalar la campana desconecte la electricidad en la caja el ctrica principal si es una estufa el ctrica APAGUE EL GAS ANTES DE MOVER UNA ESTUFA DE GAS 1 2 Abra los oficios preperforados en la campana como se muestra en la Figura 4 Si fuera necesario organice los cables el ctricos de modo que corran dentro del agujero de 1 de di metro en la parte superior o en la parte posterior d
20. dessus du comptoir Isurface de cuisson jusqu au dessous de la hotte D gagement minimum 27po 30po D hauteur de la hotte E hauteur du Couvre Conduit calcul F D F hauteur recommand e pour l installation de la hotte calcul B C 38 AVERTISSEMENT LES HOTTES COMPORTENT DES REBORDS TR S AFFIL S NOUS RECOMANDONS LE PORT DE GANTS PROTECTEURS LORS DE L INSTALLATION LE NETTOYAGE ET L ENTRETIEN MISE EN GARDE SOYEZ PRUDENT EN EMPLOYANT UN TOURNEVIS LECTRIQUE CELA POURRAIT ENDOMMAGER LA HOTTE INSTALLATIONS SOUS UNE AMOIRE Conduit SUPERE Da oen 38 ero eto ba e Ban edd le 40 ILOT Conduit Sup rieur RR 42 Conduit Arri r dl tel 45 39 INSTALLATION SOUS UNE ARMOIRE CONDUIT SUP RIEUR Pr paration avant l installation NOTE AFIN D VITER QUE VOTRE HOTTE NE SUBISSE DES DOMMAGES ASSUREZ VOUS QUE L OUVERTURE N EST PAS BLOQUEE QUE DES D BRIS NE PEN TRE DANS L OUVERTURE DES CONDUITS l emplacement du conduit d a ration qui cheminera de la hotte vers l ext rieur Voir Photo 1 Un parcours droit court et dirig permettra la hotte de mieux performer ll est toujours pr f rable de limiter le nombre de transitions coudes et passages Les changements de direction affecteront la performance de votre hotte Connecter temporaire
21. la canalisation en accord avec les canalisation sugg r e suggestions du fabricant De l air froid La connexion du conduit n est pas scell e V rifiez l installation du conduit entre dans la correctement maison Le clapet n est pas bien install ou V rifiez l installation du clapet manque l installation Le clapet n est pas install En installant le clapet vous aiderez liminer le retour d air 60 GARANTIE CERTIFICAT DE GARANTIE KOBE d sign ici par nous ou notre garantit l acheteur original d sign ici par vous ou votre tous les produits sont fabriqu s ou fournis par nous sont exempts de d faut de fabrication et de main d uvre comme suit DEUX ANS DE GARANTIE LIMIT E POUR LES PI CES ET MAIN D OEUVRE LES SERIES KOBE PREMIUM Pendant deux ans compter de la date de votre facture originale chez un concessionnaire agr KOBE nous allons notre seule discr tion choisir de r parer ou de remplacer le produit gratuitement qui a chou en raison de d fauts de fabrication Il est de votre responsabilit exclusive de vous assurer que le produit est facilement accessible pour le technicien d effectuer les r parations Le technicien de service ne va en aucune circonstance retirer alt rer ou modifier tout dispositif construit autour et ou connect l appareil pour y acc der en vue d effectuer des r parations Au cours de la p riode de deux an
22. le mur et fixer la hotte en la hotte en place AVERTISSEMENT ASSUREZ VOUS QUE LA HOTTE EST BIEN FIXEE AVAN T DE LA RELACHER 48 Installation avec couvre conduit 4 Rep rer la position de la fixation pour couvre conduit Utiliser comme r f rence l indication E de la Table deux 2 et le mesures Page 53 54 Attacher de fa on s curitaire la fixation pour couvre conduit l aide de deux vis non fournies R f rez vous la Photo 27 NOTE la doublure du couvre conduit masquera la fixation 5 Brancher les fils lectriques Voir la section Branchement des fils lectriques la Page 48 6 Glisser la doublure du couvre conduit environ 2 pouces avant d introduire le couvre conduit entier Voir la Photo 28 Photo 27 Photo 28 7 Ajuster la hauteur de la doublure int rieure du couvre conduit a la fixation du couvre conduit S curiser la doublure int rieure du couvre conduit avec deux 4x8 mm vis fournies tel comme indiqu la Photo 29 ttacher ensemble Photo 29 8 Attacher la doublure ext rieure du couvre conduit l adaptateur d chappement multi conduits de la hotte avec les quatre vis 4x8 mm fournies 49 Connexion l alimentation d nergie AVERTISSEMENT DE SECURITE POUR R DUIRE LE RISQUE D INCENDIE OU D LECTROCUTION L APPAREIL DOIT TRE CORRECTEMENT MIS A LA TERRE LES TRAVAUX D INSTALLATION ET DE C BLAGE LECTRIQUE DOIVENT TRE FAITS PAR UN LECTRICIEN QUALIFI CONFORM MEN
23. 0214 86 MEDIDAS Y DIAGRAMAS EE 87 LISTADO DE PIEZAS ostro tes e te te Ne E M e M 89 DIAGRAMA DE CIRCUITO EEN 91 INSTRUCCIONES IMPORTANTES DE SEGURIDAD ecce aa aa ae 92 I D a uU ca ala aa E A AM LA M 93 REGISTRO D L PRODUCTO EE 95 LEA CUIDADOSAMENTE TODAS LAS INSTRUCCIONES ANTES DE COMENZAR TODO EL CABLEADO DEBER REALIZARSE POR UN PROFESIONAL Y DE ACUERDO CON TODOS LOS CODIGOS ELECTRICOS NACIONALES Y LOCALES 221547 66 INSTRUCCIONES IMPORTANTES DE SEGURIDAD POR FAVOR LEA CUIDADOSAMENTE ESTA SECCI N ANTES DE INSTALAR A ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO ELECTROCUCION O LESION PERSONAL TOME EN CUENTA LO SIGUIENTE La instalaci n y el cableado el ctrico deber n realizarse por profesionales calificados y de acuerdo con todos los c digos y est ndares correspondientes incluyendo los c digos y normas sobre la construcci n para prevenir incendios Al cortar o perforar una pared o techo tenga cuidado de no da ar el cableado el ctrico u otras instalaciones de servicios ocultas Los ventiladores con conductos deber n tener una ventilaci n hacia el exterior a Antes de darle servicio o limpiar la unidad abra el panel de la luz y DESCONECTE EL SUMINISTRO EL CTRICO EN EL PANEL DE SERVICIO b Limpie frecuentemente las superficies saturadas con grasa Para reducir el riesgo de incendio y para dispersar el aire adecuadamente aseg rese de ventilar el aire al exteri
24. 6 Commercial Grade Stainless Steel 30 232W 2 21A 36 232W 2 21A 2 18 Gauge Seamless Satin Finish Twin Turbine Impeller Top 6 Round 7 Round 3 1 4 x 10 Rectangular Rear 3 1 4 x 10 Rectangular Electronic Control 4 Buttons 10 Second Standby Startup 30 Second Delay Shutoff 30 12V 20W x 2 36 12V 20W x 2 CH2230SQB 29 3 4 x 22 x 5 7 8 CH2236SQB 35 3 4 x 22 x 5 7 8 1 Two Piece Adjustable Duct Cover CH1120DC 11 3 4 x 10 1 4 x 20 5 8 39 3 4 2 30 Stainless Steel Back Panel SSP30 30 x 1 10 x 32 3 36 Stainless Steel Back Panel SSP36 36 x 1 10 x 32 Net Gross CH2230SQB 44 0 50 6 CH2236SQB 46 0 52 6 QuietMode Low Medium High 300 450 600 720 1 2 3 0 4 5 4 8 Specifications subject to change without notice 22 9 1 8 230 MEASUREMENTS 8 DIAGRAMS 9 1 8 230 All inch measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE gt 062 8 1 6 30 Knockout Holes A 36 42 48 Knockout Holes A amp B FOR WALL MOUNT WITH OPTIONAL DUCT COVER 9 1 8 230 48 7 8 1240 MAX 29 3 4 755 23 7 1 2 190 Hood Mounting Bracket 10 254 8 3 16 208 SE a a io N 5 2
25. Apr s Pas d alimentation lectrique Assurez Utilisez un voltm tre pour v rifier l alimentation en l installation vous que le disjoncteur et que lectricit les deux l alimentation lectrique moteurs et soient en marche les lumi res ne fonctionnent pas Le c blage n est pas bien install V rifiez et serrez les connexions de fils Le c blage du panneau de commande et de la carte processeur est d branch V rifiez le c blage au complet partir du panneau de commande jusqu la carte processeur Le transformateur du moteur est d fectueux V rifiez l entr e de courant et la sortie de courant du transformateur du moteur Si n cessaire remplacez le transformateur du moteur Le panneau de commande ou la carte processeur est d fectueux Remplacez le panneau de commande ou la carte processeur Les lumi res fonctionnent mais pas le s Le s moteur s est sont d fectueux Remplacez le s moteur s Le s condensateur s est sont d fectueux Remplacez le s condensateur s moteur s Le panneau de commande ou la carte Remplacez le panneau de commande ou la carte processeur est d fectueux processeur La hotte de Le syst me de ventilation n est pas bien Serrez la pale turbine cage d cureuil et le r servoir cuisine vibre install d air La pale turbine cage cureuil n est pas Remplacez la pale turbine cage d cure
26. C Preferred Height of Counter Top to Hood Bottom Minimum 27 to 30 D Height of Hood E Height of Duct Cover F D F Height of the Hood Installation A B C H m OU A gt SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents UNDER THE CABINET A A oes ee ee A E AN 7 A 9 WALL MOUNT TOPO i i p TEE 11 Rear Ventor ES lls ea ne 14 UNDER THE CABINET INSTALLATION TOP VENT Preparation before Installation NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ENTERING THE VENT OPENING Decide the location of the venting pipe from the hood to the outside Refer to Figure 1 A straight short venting run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood Temporarily wire the hood to test for proper operation before installing Peel protective film off the hood if any For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not included on each side Refer to Figure 2 Measure and create access opening for
27. CORE DE LAINES A R CURER Un entretien fr quent aidera conserver une belle apparence la hotte 1 2 Utiliser seulement du savon doux ou du d tergent S cher les surfaces avec un chiffon doux Si la hotte est tach e hotte en acier inoxydable utiliser un nettoyant pour acier inoxydable pour nettoyer les surfaces de la hotte Eviter de mettre du nettoyant sur le panneau de commande Suivre les directives du nettoyant pour acier inoxydable Avertissement Ne jamais laisser de nettoyant durant une longue p riode de temps puisque ceci pourrait endommager la finition de la hotte Utiliser un chiffon doux pour enlever tout r sidu de solution nettoyante frotter l g rement toutes taches tenaces S cher la hotte avec un chiffon doux S cher la hotte avec un chiffon doux NE PAS laisser les d p ts s accumuler durant de longues p riodes de temps NE PAS utiliser de laines ou de brosses r curer ordinaires Des particules d acier peuvent adh rer la surface et la faire rouiller NE PAS permettre des solutions salines des d sinfectants des javellisants ou des agents nettoyants de rester en contact avec l acier inoxydable durant de longues p riodes Plusieurs de ces nettoyants contiennent des produits chimiques pouvant causer du tort l acier inoxydable Apr s tout contact de ce type rincer l eau et essuyer avec un chiffon doux Nettoyage Des Filtres D flecteurs Et Du R cup rateur Graisse A
28. Locales Estatales y Federales 68 COMPONENTES DEL PAQUETE Debe conservar todo el material en caso de devolverlo o solicitar un reembolso Caja de la Campana de Extracci n Caja de la Cubierta de Conductos Vendida por Separado A Campana de Extracci n KOBE 1 B Tarjeta de Registro de Garant a 1 Manual de Instrucciones 1 D Cubierta de Ventilaci n Arriba 1 E Filtro Deflector 2 30 3 36 F Carcasa Inferior 2 2 30 E D F G Cubierta de Conductos 1 H Paquete de Tornillos 1 1 Soporte de Montaje de la Cubierta de Conductos 1 J Soporte de Montaje de la Campana 1 1 CUBIERTA DE CONDUCTOS INTERNA CUBIERTA DE CONDUCTOS EXTERNA e 3 16 x 3 8 9 pcs 8 4 8 mm 8 pcs gt Ke sP Base de Goma 2 pcs J PARA OBTENER M S INFORMACI N POR FAVOR VISITE NUESTRO SITIO DE INTERNET www KOBERangeHoods com O CONTACTE A KOBE RANGE HOODS AL 626 775 8880 69 INSTALACI N POR FAVOR LEA LAS INSTRUCCIONES COMPLETAMENTE ANTES DE CONTINUAR C lculo antes de la Instalaci n Para realizar el c lculo para la instalaci n por favor consulte la TABLA 1 Todos los c lculos est n hechos en pulgadas PARA INSTALACI N DEBAJO DEL GABINETE TABLA 1 A Altura del Piso al Techo B Altura del Piso a la Superficie del Mo
29. ROBE KOBE Brand Range Hood Model N de mod les Modelo No CH2230SQB 22365 CH 122 SERIES 6 HEIGHT INSTALLATION INSTRUCTIONS AND OPERATION MANUAL MANUEL D INSTALLATION ET MODE D EMPLOI INSTRUCCIONES DE INSTALACION Y MANUAL DE OPERACION ENGLISH FRENCH SPANISH READ BEFORE INSTALLATION 1 Carefully check all contents of packages 2 Thoroughly inspect the unit for any cosmetic damages or defects 3 Test the unit before installation 4 Have a certified contractor electrician do the installation IF THERE IS PROBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original proof of purchase and product serial number ready 3 Call 1 877 BUY KOBE 289 5623 or e mail to info Qkoberangehoods com to report the problem ENGLISH READ AND SAVE THESE INSTRUCTIONS CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 tret dox oo sad e orent dece ca See tate 5 INSTALLATION EE 6 OPERATING ANS TRUCTION Soprano naaa efi 19 MAINTENANCE 022 1205 d 22 eed ds 20 SPEGIFIGATIONS s anota A ataca fe Attac tec ae D CM EA 22 MEASUREMENTS amp DIAGRAMS 23 PARTS LIN ti 25 STG UIT DAS FRAN EE 27 TROUBLE SHOOTING 28 WA RRAN Error Bookmark not defined PRODUCT
30. SIGN TYPE DE VENTILATEUR VACUATION COMMANDES LAMPES HALOGENES DIMENSIONS DE LA HOTTE LARGEUR X PROFONDEUR X HAUTEUR ACCESSOIRES EN OPTION LARGEUR X PROFONDEUR X HAUTEUR POIDS DE LA HOTTE Ib VITESSE Capacit d air cfm Sone CH2230SQB 30 po CH2236SQB 36 po Acier inoxydable de qualit commerciale 30 232 W 2 21 A 36 po 232 W 2 21 A 120 V 60 Hz 2 Fini satin sans joints de calibre 18 Fini satin Pale de turbine double Sur le dessus 6po rond 7po rond 3 1 4po x 10po Rectangulaire A l arri re 3 1 4po x 10po Rectangulaire Commandes lectroniques 4 boutons D marrage avec garde de 10 secondes Dispositif d arr t retardement de 30 secondes 30 po 2 ampoules 12 V 20 W 36 po 2 ampoules 12 V 20 W CH2230SQB 29 3 4 x 22 x 5 7 8 CH2236SQB 35 3 4 x 22 x 5 7 8 1 Couvre conduit r glable en deux pi ces CH1120DC 11 3 4 10 1 4 x 20 5 8 39 3 4 2 Panneau arri re en acier Inoxydable de 30 SSP30 30 x 1 10 x 32 3 Panneau arri re d acier Inoxydable de 36 SSP36 36 x 1 10 x 32 CH2230SQB SZ CH2236SQB QuietMode Basse Moyenne 300 450 600 1 2 3 0 4 5 Les sp cifications sont sujettes a changement sans pr avis 54 lev e 720 4 8 MESURES et DIAGRAMMES Toutes les mesures de pouce sont converties partir de millim tres Les mesures en pouces sont estim es Toutes les mesures
31. T AUX CODES NATIONAUX ET LOCAUX LECTRIQUES APPLICABLES AVANT DE CONNECTER CET APPAREIL ETEIGNEZ L ALIMENTATION A PARTIR DU PANNEAU ELECTRIQUE PRINCIPAL ET BLOQUER LE DISPOSITIF DE D CONNEXION POUR EMP CHEZ QUE LE POUVOIR NE SOIT ACCIDENTELLEMENT RALLUM Connecter les fils lectriques Raccorder les trois fils noir blanc et vert aux fils de la maison et couvrez les avec des capuchons de connexion Raccorder les fils selon la couleur noir avec noir blanc avec blanc et vert avec vert S assurer que les fils ne glissent pas entre le moteur et toute autre pi ce en mouvement en les enfoncant ad quatement dans la boite lectrique Assemblage final 1 Placer les filtres d flecteurs sous la hotte Voir photo 30 Photo 30 50 MODE D EMPLOI Cette hotte de cuisini re KOBE poss de quatre commandes lectroniques munies d un d marrage avec garde de 10 secondes et d un dispositif d arr t retardement de 30 secondes deux puissants ventilateurs avec filtres d flecteurs et lampes halog nes 12 volts 20 watts Il existe quatre commandes lectroniques la commande des lampes Light control la commande de vitesse A Speed Control A la commande de vitesse B Speed Control B et la commande marche arr t ON OFF Voir photo 31 Commande de lampe Commande Marche Arr t Contr le de Vitesse A Contr le de Vitesse B Cycles bas QuietMode H haut et moyen Cycles bas moyen lev et
32. UTION DRAIN OIL FROM BAFFLE FILTER amp OIL TUNNEL REGULARLY TO PREVENT OVERFLOW 1 Remove all the baffle filters and oil tunnel 2 Using a sponge wash with warm soapy water Dry completely before returning into place Note Baffle Filters are top rack dishwasher safe 20 To Replace Light Bulb CAUTION HALOGEN LIGHT UNIT MAY HOT WAIT UNTIL UNIT IS COOL NOTE DO NOT TOUCH HALOGEN LIGHT WITH BARE HANDS WHICH MIGHT CAUSE OVER HEAT AND SHORTEN THE LIFT OF LIGHT BULBS HALOGEN LIGHT GLASS COVER HALOGEN LIGHT HOUSING HALOGEN LIGHT BULB 12V 20W FLAT HEADED CREWDRIVER 1 Make sure all controls are off and range hood is unplugged 2 Place the flat headed screwdriver into the groove of the halogen light glass covering and the housing O 3 Pop out the halogen light glass covering 4 Gently pull out the defective light bulb and discard Light bulbs should be 12V 20W maximum Using a cloth hold the new light bulb and push securely into light socket Return halogen light glass cover to the housing Turn range hood ON to test for operation Noo 21 SPECIFICATIONS MODEL SIZE COLOR CONSUMPTION AMPERE NUMBER OF MOTORS DESIGN FAN TYPE EXHAUST CONTROLS HALOGEN LIGHTS Or LED if Available HOOD DIMENSION W x D x H OPTIONAL ACCESSORIES W x D x H WEIGHT lbs SPEED Air Capacity cfm Sone CH2230SQB 30 CH2236SQB 3
33. VERTISSEMENT VIDER LES FILTRES D FLECTEURS ET LE R CUP RATEUR GRAISSE AVANT QU IL N Y AIT TROP D ACCUMULATION 1 Retirer les filtres d flecteurs et le r cup rateur graisse 2 l aide d une ponge laver dans une eau chaude savonneuse S cher enti rement avant de remettre en place Note les filtres peuvent tre nettoy s en toute s curit dans le haut du lave vaisselle 52 Remplacement d une ampoule AVERTISSEMENT O Bo tier Plaque de lampe verre alog n Lampe halog LA LAMPE HALOG NE PEUT TRE BR LANTE ATTENDRE QU ELLE SE REFROIDISSE AVANT DE PROC DER Tournevis t te plate Lampe halogene Ampoule 12 OW 1 S assurer que toutes les commandes sont en mode ARRET et que la hotte de cuisini re est d branch e 2 Glisser le tournevis a t te plate dans l espace entre la plaque de verre et le boitier de la lampe 3 Retirer la plaque de verre 2 4 En douceur tirer sur l ampoule d faillante pour l enlever et la jeter Les ampoules utiliser doivent tre de 12 V et de 20 W au maximum O NO Ol 53 l aide d un linge tenir la nouvelle ampoule et la pousser fermement dans la douille Remettre la plaque de verre par dessus le bo tier O Brancher la hotte de cuisini re pour en v rifier le fonctionnement SP CIFICATIONS MOD LE FORMAT COULEUR CONSOMMATION VOLTAGE NOMBRE DE MOTEURS DE
34. a de la campana si hay alguna Para instalar debajo del gabinete con la parte inferior empotrada coloque tiras para rellenar madera de 4 pulgadas de ancho no incluidas de cada lado Consulte la Figura 7 Mida y haga una abertura de acceso para los cables el ctricos debajo del gabinete o el orificio de acceso para los cables el ctricos en la parte posterior de la campana Remueva los tornillos de la cubierta de ventilaci n posterior y corte a lo largo de la l nea del orificio de la cubierta interna de ventilaci n posterior Consulte la Figura 8 Corte el orificio de la cubierta de ventilaci n posterior y regrese al otro lado Consulte la Figura 9 Vuelva a colocar la cubierta de ventilaci n posterior TAPA DEL TECHO GABINETE CAMPANA 4 ancho Figura 6 a Cubierta de Ventilaci n Cubierta Interna Cubierta de Posterior Ventilaci n Revertida Posterior N gt dl Figura 8 Figura 9 74 Instalaci n de la Campana PRECAUCI N Si fuera necesario mover la estufa para instalar la campana desconecte la electricidad en la caja el ctrica principal si fuera una estufa el ctrica APAGUE EL GAS ANTES DE MOVER UNA ESTUFA DE GAS 1 Abra los oficios preperforados en la campana como se muestra en la Figura 10 2 Desatornille y remueva el escape de multi conductos Reemplace con la cubierta de ventilaci n D superior Consulte la Figura 11 Figura 10 Figura 11 3 Si fuera necesario orga
35. a entre la cubierta de vidrio de los focos de hal geno y la carcasa O 3 Retire cuidadosamente la cubierta de vidrio de la carcasa 4 Hale suavemente el foco inservible y des chelo Los focos deber n ser de 12V 20W como m ximo 5 Utilice un guante o un pa o para sujetar el nuevo foco y emp jelo para colocarlo en el recept culo para focos NOTA NO LO EMPUJE DEMASIADO FUERTE PUES PODR A QUEBRAR EL CONECTOR PARA FOCO 6 Coloque nuevamente la cubierta de vidrio de los focos de hal geno O 7 Enchufe nuevamente el cable de corriente y encienda la campana de extracci n para verificar su funcionamiento 85 ESPECIFICACIONES MODELO TAMA O COLOR CONSUMO AMPERIOS NUMERO DE MOTORES DISE O TIPO DE VENTILADOR EXHAUST CONTROLES FOCOS DE HAL GENO Or LED if Available DIMENSI N DE LA CAMPANA ANCHO x PROFUNDIDAD x ALTO ACCESORIOS OPCIONALES ANCHO x PROFUNDIDAD x ALTO PESO Ibs VELOCIDAD Capacidad de Aire cfm Sonio CH2230SQB 30 CH2236SQB 36 Acero Inoxidable de Clasificaci n Comercial 30 232W 2 21A 36 232W 2 21A 2 Liso Calibre 18 Acabado Satinado Impulsor de Doble Turbina Superior Redondo de 6 Redondo de 7 Rectangular de 3 1 4 x 10 Posterior Rectangular de 3 1 4 x 10 Control Electr nico 4 Botones Encendido en Espera de 10 Segundos Apagado con Retraso de 30 Segundos 30 12V 20W x2 36 12V 20W x2 223050
36. amente e Si solo las luces estuvieran encendidas oprimir el bot n de Encendido Apagado una vez har que la unidad se apague luego de 30 segundos 83 MANTENIMIENTO Para un funcionamiento ptimo limpie la de extracci n y todos los deflectores separadores filtros conductos de aceite recipientes para aceite con regularidad Limpieza de la Superficie de la Campana PRECAUCI N NUNCA UTILICE LIMPIADORES ALMOHADILLAS PA OS ABRASIVOS NO UTILICE TOALLAS DE PAPEL SOBRE EL ACERO INOXIDABLE El cuidado regular ayudar a preservar la apariencia de la campana 1 Utilice solamente jab n o soluciones detergentes suaves Seque las superficies utilizando un pa o suave 2 Si la campana se ve manchada campana de acero inoxidable utilice un limpiador para acero inoxidable para limpiar la superficie de la campana Evite que la soluci n de limpieza caiga sobre o en el panel de control Siga las instrucciones del limpiador de acero inoxidable Precauci n No lo deje por mucho tiempo pues podr a da ar el acabado de la campana Utilice una toalla suave para limpiar la soluci n de limpieza y frote cuidadosamente cualquier rea dif cil de limpiar Utilice una toalla suave y seca para secar la campana 3 NO permita que dep sitos se acumulen o permanezcan sobre la campana 4 NO utilice lana de acero o cepillos de acero ordinarios Peque os pedazos de acero podr an adherirse a la superficie y causar xid
37. and Federal Codes COMPONENTS OF PACKAGE Must keep all material for returns or refunds Range Hood Box A KOBE Range Hood 1 B Warranty Registration Card 1 Instructions Manual 1 D Vent Cover Top 1 E Baffle Filters 30 2 36 3 F Bottom Casing 30 2 A B C D E F Duct Cover Box Sold Separately G Adjustable Duct Cover 1 Screws Package 1 1 Duct Cover Mounting Bracket 1 J Hood Mounting Bracket 1 G Inner Duct Cover Outer Duct Cover H 1 B 3 16 x 3 8 9 pcs Li 4 x 8 mm 8 pcs p pf Rubber Stand 2 pcs FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 5 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation please refer to TABLE 1 All calculation in inches FOR UNDER THE CABINET TABLE 1 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 27 to 30 D Height of Hood E Height of the Cabinet T Cabinet E L D nu T FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36
38. ct cover mounting bracket Use reference E from Table 2 for references Attach and secure duct cover mounting bracket with two screws not provided Refer to Figure 27 NOTE Inner duct cover will cover the mounting bracket Connect electrical wires Refer to Wiring to Power Supply on Page 17 Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood Refer to Figure 28 Figure 27 Figure 28 Adjust the height of the inner duct cover to the duct cover mounting bracket Secure the inner duct cover with two 4x8 mm screws provided as shown in Figure 29 Attach Together Figure 29 Fasten outer duct cover to multi vent exhaust on the hood with four 4x8 mm screws provided 17 Wiring to Power Supply A SAFETY WARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY Connect the electrical wires Connect three wires black white and green to house wires and cap with wire connectors Connect according to color black to black white to white and green to green f necessary to hide the electrical wire connections push wires back into the wiring box Access the wire connections underneath the hood Make sure wires do
39. d le 3 Num ro de s rie Pour le service de garantie ou achat de pieces contactez CENTRE DE SERVICE KOBE Num ro vert 1 855 800 KOBE 5623 Email kobe 2adcoservice com Pour signaler un probleme contactez Num ro vert 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com Pour des informations sur les produits contactez Num ro vert 1 877 BUY KOBE 289 5623 Email info koberangehoods com Vos remarques 63 ESPA OL LEA ANTES DE LA INSTALACION 1 Revise cuidadosamente todos los contenidos del paquete 2 Inspeccione cuidadosamente la unidad para los da os o defectos est ticos 3 Pruebe la unidad antes de la instalaci n 4 Deje que un contratista certificado electricista realice la instalaci n SI HAY ALGUN PROBLEMA 1 NO INSTALE LA UNIDAD Y GUARDE EL EMPAQUE ORIGINAL 2 Tenga su recibo original de compra y n mero de serie del producto listo 3 Llame al 1 877 BUY KOBE 289 5623 o env e correo electr nico a info koberangehoods com para informar del problema 65 SPANISH LEA Y CONSERVE ESTAS INSTRUCCIONES NDICE INSTRUCCIONES IMPORTANTES DE SEGURIDAD eee 67 COMPONENTES DEL PAQUETE 69 INSTALAGIONE e eedem Ra LUNA ans 70 INSTRUCCIONES DE OPERACI N 5 tat ue iia 83 MANTENIMIENTO e e Ot E RE nt 84 ESPECIFICACIONES cccccccccccccccicc2222222222222222222022222202 02020
40. do en la parte posterior de la campana con la red de conductos Utilice cinta de aislar para hacer que todas las uniones queden seguras y herm ticas 3 Alinee el soporte de montaje de la campana con los dos tornillos en la pared y enganche la campana en su lugar Apriete los tornillos para asegurar la campana en la pared PRECAUCION ASEGURESE QUE LA CAMPANA ESTE FIJA ANTES DE SOLTARLA 80 Instalaci n de la Cubierta de Conductos 4 Marque la posici n del soporte de montaje de la cubierta de conductos Utilice la referencia E de la Tabla 2 y las medidas en las P ginas 84 85 Coloque y asegure el soporte de montaje de la cubierta de conductos con dos tornillos no incluidos Consulte la Figura 27 NOTA La cubierta interna de conductos cubrir el soporte de montaje Conecte los cables el ctricos Consulte Cableado a la Fuente de Alimentaci n en la P gina 79 Deslice la cubierta interna de conductos hasta 2 pulgadas antes de deslizar completamente la cubierta de conductos en la campana Consulte la Figura 28 Figura 27 Figura 28 Ajuste la altura de la cubierta interna de conductos al soporte de montaje de la cubierta de conductos Asegure la cubierta interna de conductos con dos tornillos de 4x8 mm incluidos como se muestra en la Figura 29 F jelos Juntos Figura 29 Fije la cubierta externa de conductos con el escape de multi conductos de ventilaci n en la campana con cuatro tornillos de 4x8 mm incluidos
41. ductos Asegure la cubierta interna de conductos con dos tornillos de 4x8 mm incluidos como se muestra en la Figura 20 F jelos Juntos Figura 20 Sujete la cubierta externa de conductos con el escape de multi conductos de ventilaci n en la campana utilizando cuatro tornillos de 4x8 mm incluidos 78 INSTALACI N INDEPENDIENTE VENTILACI N POSTERIOR Esta instalaci n s lo aplica con la compra de una cubierta de conductos Preparaci n antes de la Instalaci n NOTA PARA EVITAR CAUSAR DA OS A SU CAMPANA EVITE QUE DESECHOS PENETREN EN LA RENDIJA DE VENTILACI N Decida la ubicaci n para colocar el conducto de ventilaci n de la campana hacia el exterior Consulte la Figura 21 Un ducto de escape recto y corto permitir que la campana trabaje con m s eficiencia Intente evitar tantas conexiones codos y ductos largos como sea posible Esto podr a reducir el rendimiento de la campana Utilice cinta de aislar para sellar las uniones entre las secciones del tubo Si fuera necesario prepare un marco posterior en la pared con madera de entramado para una instalaci n segura Utilizando las referencias de la Tabla 2 y las medidas en la P gina 84 85 decida el nivel de la madera Consulte la Figura 22 Preparaci n de la Campana antes de la Instalaci n Conecte la campana temporalmente para probar su operaci n antes de instalar Retire la pel cula protectora de la campana y de la cubierta de conducto
42. e 1 and measurements on Page 22 to center the hood in place beneath the cabinet and flush with the front of the cabinet Place screw not provided into the exact center of each knockout hole Make sure all screws are in place before tightening screws CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING gt 1 Diameter Hole Figure 12 Ductwork Installation 6 Use aluminum or steel pipe to connect the exhaust opening at the rear of the hood to the ductwork Use duct tape to make all joints secure and air tight 11 WALL MOUNT INSTALLATION TOP VENT This installation only applied with the purchase of a duct cover Preparation before Installation NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ENTERING THE VENT OPENING Decide the location of the venting pipe from the hood to the outside Refer to Figure 13 A straight short venting run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood Use duct tape to seal the joints between pipe sections If necessary prepare back wall frame with cross framing lumber for secure installation Using references on Table 2 and measurements on Page 22 23 decide the level of the lumber Refer to Figure 14 Hood Preparation before Installation Temporarily wire the hood to test for proper operation before installing Peel protective film off the hood and the duct cove
43. e la campana Consulte la Figura 5 Utilizando las referencias en la Tabla 1 y las medidas en la P gina 84 centre la campana en su lugar debajo del gabinete y nivele con el frente del gabinete Agujero de un de di metro 1 Figura 4 Figura 5 Tire de los cables el ctricos por medio del orificio de acceso del gabinete Coloque el tornillo no incluido en el centro exacto de cada agujero preperforado Aseg rese de que todos los tornillos est n en su lugar antes de apretarlos PRECAUCION ASEGURESE QUE LA CAMPANA ESTE FIJA ANTES DE SOLTARLA Instalaci n de Red de Conductos 6 Utilice un tubo de aluminio o acero para conectar el escape pl stico en la campana a la red de conductos de arriba Utilice cinta de aislar para asegurar y hermetizar todas las uniones 73 INSTALACI N DEBAJO DEL GABINETE VENTILACI N POSTERIOR Preparaci n antes de la instalaci n NOTA PARA EVITAR CAUSAR DA OS A SU CAMPANA EVITE QUE DESECHOS PENETREN EN LA RENDIJA DE VENTILACI N Decida la ubicaci n para colocar el conducto de ventilaci n de la campana hacia el exterior Consulte la Figura 6 Un ducto de escape recto y corto permitir que la campana trabaje con m s eficiencia Intente evitar tantas conexiones codos y ductos largos como sea posible Esto podr a reducir el rendimiento de la campana Antes de instalar conecte temporalmente la campana para verificar que funcione adecuadamente Retire la pel cula protector
44. e of the designated service area Purchases from unauthorized dealers 7 eroaopp 29 m Removal fees of defective product and Installation fees associated with replacement product If we determine that the warranty exclusions listed above apply or if you fail to provide all necessary documentation for warranty service you will be responsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request To qualify for warranty service you must Have the ORIGINAL proof of purchase Be the ORIGINAL purchaser of the product Have the model number Have the serial number Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER ur wem KOBE SERVICE CENTER 1 855 800 5623 E mail kobe adcoservice com 30 WARRANTY INFORMATION FORM Fill in the blanks and keep this paper with the original invoice in a safe place for future service purpose 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com To report a problem please contact Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com For product information contact Toll free 1 877 BUY KOBE
45. e the motor working but The capacitor s is defective Replace capacitor s motor s is not The control panel or processor board is defective Replace the control panel or processing board The range The blower system is not secure Tighten the turbine impeller squirrel cage and air hood is chamber vibrating The turbine impeller squirrel cage is Replace the turbine impeller squirrel cage not balanced Hood is not secured in place Check the installation of hood tighten the mounting bracket The motor is Halogen Light bulb s is defective Try placing the trouble light bulb s to a working working but socket if the bulb s still doesn t work replace the lights are the halogen light bulb s not working The light wiring s is loose Check wire continuity from processor board to light transformer to halogen light housing s Light transformer is defective Check power input and power output on the light transformer If it s needed replace the light transformer The control panel or processor board is Replace the control panel or processing board defective The range The range hood is installed outside of Adjust the clearance between the range hoods hood is not the manufacture recommended and cook top to 27 to 30 For Island range venting out clearance hood the clearance between the range hoods correctly and cook top is 30 to 36 There is no make up air inside the Open the window
46. e warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood AWARNING TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE TOP GREASE FIRE Keep all fan baffle spacer filter oil tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spacer filter oil tunnel oil container Always turn hood ON when cooking Use high settings on cooking range ONLY when necessary Do not leave cooking range unattended when cooking Always use cookware and utensils appropriate for the type and amount of food prepared Use this unit only in the manner intended by the manufacturer Before servicing switch power off at service panel and lock service panel if possible to prevent power from switching on accidentally Clean ventilating fan frequently NOg RON 00 What to Do In The Event Of a Range Top Grease Fire e SMOTHER FLAMES with a tight fitting lid cookie sheet or metal tray and then turn off the burner KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES If the flames do not go out immediately EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911 NEVER PICK UP A BURNING PAN You May Get Burned DONOT USE WATER including wet dishcloths or towels a steam blast will result Use an extinguisher ONLY if a You have
47. electrical wires under the cabinet Cut the multi duct exhaust according to the size of the venting pipe Refer to Figure 3 6 Round Vent 7 Round Vent 3 1 4 x 10 Vent Figure 3 Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE 1 the knockout holes on the hood as shown in Figure 4 2 If necessary arrange the electrical wires to run through the 1 diameter hole on the top or the rear of the hood Refer to Figure 5 3 Using references on Table 1 and measurements on Page 22 to center the hood in place beneath the cabinet and flush with the front of the cabinet Figure 4 Figure 5 4 Draw electrical wires through cabinet access opening 5 Place screw not provided into the exact center of each knockout hole Make sure all screws are in place before tightening screws CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING Ductwork Installation 6 Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above Use duct tape to make all joints secure and air tight UNDER THE CABINET INSTALLATION REAR VENT Preparation before installation NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ENTERING THE VENT OPENING Decide the location of the venting pipe from the hood to the outside Refer to Figure 6 A straigh
48. ent d air pour une combustion et une vacuation des gaz appropri es par le conduit de fum e chemin e afin d viter le refoulement d air Suivre les directives et les consignes de s curit des fabricants d quipement de chauffage comme celles publi es par le National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE de m me que les codes en vigueur L activation de tout interrupteur peut provoquer l allumage ou une explosion En raison de la taille et du poids de la hotte il est recommand que deux personnes participent l installation 2 7 CD 7 SE AVERTISSEMENT RISQUE DE CHOC LECTRIQUE Pouvant entra ner la mort ou des blessures graves Couper l alimentation ons lectrique l appareil avant tout entretien ou toute r paration Si la hotte est munie d une ampoule fluorescente cette derni re contient une petite quantit de mercure et en cons quence elle doit tre recycl e ou limin e conform ment aux codes locaux provinciaux et f d raux qui s appliquent 36 CONTENU DE LA BO TE Vous devez conserver tout le mat riel pour les retours ou les remboursements Bo te contenant la hotte A Hotte KOBE 1 B Carte d enregistrement de garantie 1 Manuel d installation et d op ration 1 D Plaque de sortie verticale 1 E Filtre d flecteur 2 30po 3 36p
49. entre parenth ses sont des millim tres SOUS LE CABINET 0 Trous de montage percage 36po 42 48po Trous de montage A et GERS T rw 062 8 1 6 9 1 8 230 9 1 8 230 9 1 8 230 48 7 8 1240 MAX 29 3 4 755 55 Support de fixation hotte Support de fixation couvre conduit 10 254 8 3 187 208 250 4100 56 LISTE DES PI CES N de mod les CH2230SQB 22365 N DESCRIPTION MODELE FORMAT N DE PIECE 1 Adaptateur de sortie multi conduit C1 0507 1530 2 Plaque de sortie verticale B101 1530 12 3 Vis de plaque pour sortie verticale C1 0508 1530 A 4 Adaptateur rectangulaire sortie arri re C1 0508 1530 B 5 Caisson sup rieur de la hotte GH2230S50B 10 1630A 22365 10 1636A 6 Lumi res halog nes 12V 20W max C1 0403 0101 7 Bo tier de contr le C1 0501 0101 8 Tableau de commandes contr le C1 0404 4001 A 9 Support de contr le C1 0207 5200 10 Support de transformateur C1 0201 1530 11 Transformateur moteur C1 0207 5200 12 Bo tier de moteur A Bo tier de moteur sup rieur CH2230SQB B Bo tier de moteur lat ral CH2230SQB A Bo tier de moteur sup rieur CH2236SQB B Boitier de moteur lat ral CH2236SQB 22305
50. es pour les fils lectriques sous le cabinet ou raccorder passant par l ouverture pour les fils l arri re de la hotte Retirer les vis sur la plaque de sortie arri re et couper le long de la ligne d ouverture du conduit int rieur Voir Photo 8 Couper la plaque de sortie arri re et changez la de c t R f rez vous la Photo 9 Rattachez la plaque de sortie arri re Conduits Photo 7 Couvercle i int rieur arr re Couvercle invers arri re al Photo 8 Photo 9 42 AVERTISSEMENT S il faut d placer une cuisini re lectrique pour installer la hotte couper d abord l alimentation lectrique cette cuisini re par le tableau de distribution principal COUPER LE GAZ AVANT DE D PLACER UNE CUISINIERE A GAZ 1 Perforer les trous de d cochage sur la hotte tel qu indiqu la Photo 10 2 D visser et retirer l adaptateur de sortie multi conduits Remplacez le par la plaque de conduit en forme de D tel qu indiqu la Photo 11 E Photo 10 Photo 11 3 Si n cessaire placer les fils lectriques pour qu ils passent au travers de la perforation de 1po de diam tre situ sur le dessus ou l arri re de la hotte Veuillez vous r f rer la Photo 12 4 En utilisant les r f rences de la Table 1 et les mesures la Page 53 centrer la hotte en place au dessous du cabinet vis vis le devant du cabinet Passer les fils lectriques au travers de l ouverture d acc s des
51. fournies exactement au centre de chaque trou de d cochage Assurez vous toutes les vis sont en place avant de les resserrer AVERTISSEMENT ASSUREZ VOUS QUE LA HOTTE EST SOLIDEMENT FIX E EN PLACE AVANT DE LA RELACHER Installation des conduits 2 Utiliser des tuyaux d aluminium ou d acier pour relier le joint de raccordement en plastique de la hotte aux conduits dessus Utiliser du ruban adh sif pour sceller les joints s rs et ainsi obtenir une parfaite tanch it 41 INSTALLATION SOUS UNE ARMOIRE CONDUIT ARRI RE Pr paration avant installation NOTE AFIN D VITER QUE VOTRE HOTTE NE SUBISSE DES DOMMAGES ASSUREZ VOUS QUE L OUVERTURE N EST PAS BLOQUEE EMPECHER QUE DES DEBRIS NE PENETRE DANS L OUVERTURE DES CONDUITS Planifier l emplacement du conduit d a ration qui cheminera de la hotte vers l ext rieur Voir Photo 6 Un parcours droit court et dirig permettra la hotte de mieux performer ll est toujours pr f rable de limiter le nombre de transitions coudes et passages Les changements de direction affecteront la performance de votre hotte Connecter temporairement la hotte afin d en v rifier le fonctionnement avant de proc der l installation finale Retirer la pellicule protectrice de la hotte s il y a lieu Lors d une installation sous un cabinet ajouter des fixations de bois d au moins 4 pouces de large non inclus sur chaque c t Voir Photo 7 Mesurer et pr voir un acc
52. ilial h L usure normale i Chips rayures ou les bosses ou de le mauvais usage du produit j Les dommages caus s par un accident un incendie une inondation et d autres forces majeures k Les frais engag s pour des services situ s l ext rieur de la zone de service 61 Les achats aupr s des revendeurs agr s m Frais d enl vement de produits d fectueux et frais installation associ s un produit de remplacement Si nous d terminons que les exclusions de garantie indiqu es ci dessus s appliquent ou si vous ne fournissez pas tous les documents n cessaires pour le service de garantie vous serez responsable de tous les frais associ s la prestation demand e y compris les pi ces la main d oeuvre l exp dition le d placement et tous autres frais li s la requ te du service Pour le service sous garantie vous devez 1 Avoir la preuve d achat originale 2 Etre l acheteur original du produit 3 Le num ro de mod le 4 Le num ro de s rie 5 Avoir une description de la nature de tout d faut dans le produit ou la pi ce POUR UN SERVICE DE GARANTIE CONTACTEZ LE CENTRE DE SERVICE KOBE HOTTES CENTRE DE SERVICE KOBE 1 855 800 KOBE 5623 E mail kobe adcoservice com 62 FORMULAIRE D INFORMATION SUR LA GARANT Remplissez les espaces vides et garder ce papier avec la facture originale dans un endroit s r pour un service futur 1 Date d achat 2 Num ro de mo
53. l motor El panel de control y la placa de procesador est n defectuosos Reemplace el panel de control o la placa de procesador Las luces est n funcionando pero el los motor es no El los motor es est n defectuoso s Reemplace el motor El los condensador es est n defectuoso s Reemplace el los condensador es El panel de control o la placa de procesador est n defectuosos Reemplace el panel de control o la placa de procesador La campana de extracci n est vibrando El sistema de ventilador no est bien sujeto Tighten the turbine impeller squirrel cage and air chamber El impulsor de turbina jaula de ardilla no est balanceado Ajuste el impulsor de turbina jaula de ardilla y la c mara de aire La campana no est bien sujeta en su lugar Verifique la instalaci n de la campana ajuste el soporte de montaje El motor est funcionando pero las luces no El los foco s de la L mpara de Hal geno est n defectuoso s Intente colocar el foco que le est dando problemas en otro recept culo que funcione si a n as ste no funciona reemplace el foco de hal geno El cableado de la luz est flojo Verifique la continuidad del cable desde la placa de procesador al transformador de la luz hasta la caja de la l mpara de hal geno El transformador de la luz est defectuoso Verifique la entrada y salida de la corriente en el
54. la hotte avec les quatre vis 4x8 mm fournies 46 INSTALLATION SOUS UN LOT CONDUIT ARRI RE Cette installation est possible uniquement avec l achat d un couvre conduit en option Pr paration avant Installation NOTE AFIN D VITER QUE VOTRE HOTTE NE SUBISSE DES DOMMAGES ASSUREZ VOUS QUE L OUVERTURE N EST PAS BLOQU E ET EMP CHER QUE DES DEBRIS NE PENETRE DANS L OUVERTURE DES CONDUITS D terminer l emplacement du conduit d a ration de la hotte vers l ext rieur R f rez vous la Photo 21 Une canalisation droite courte et dirig e permettra la hotte de s ex cuter plus efficacement Lorsque possible diminuer le nombre de transitions coudes et longueurs Les changements de direction affecteront la performance de votre hotte Utiliser un ruban adh sif en toile pour sceller tous les joints et ainsi d assurer une parfaite tanch it Si n cessaire pr parez le mur arri re avec un soutien additionnel pour une installation s curitaire En utilisant les r f rences la Table 2 et les mesures la Page 53 54 r gler la hauteur du soutien additionnel R f rez vous la Photo 22 Pr paration de la hotte avant Installation Fixer temporairement la hotte afin d en valuer le fonctionnement avant de proc der l installation permanente Retirer le film protecteur de la hotte et du couvre conduit Retirer les vis de la plaque de sortie arri re et couper le long de la ligne de l ouverture de la
55. le des distributeurs autoris s de KOBE Toute r paration effectu e sans la supervision d un agent autoris de KOBE annulera automatiquement la garantie KOBE se d gage de toute responsabilit face des dommages la propri t personnelle ou aux biens immeubles ou encore des blessures corporelles caus es directement ou indirectement par la hotte de cuisini re AVERTISSEMENT AFIN DE R DUIRE LES RISQUES DE BLESSURES CORPORELLES DANS L VENTUALIT D UN INCENDIE DE GRAISSE SE D CLARANT SOUS LA HOTTE DE CUISINI RE 1 Tenir toujours propres le ventilateur les filtres d flecteurs s il y en a et les surfaces charg es de graisse 2 Toujours faire fonctionner la hotte lors d une cuisson temp rature lev e 3 Utiliser les vitesses lev es de la hotte UNIQUEMENT lorsque n cessaire Chauffer l huile lentement aux r glages de basses ou de moyennes vitesses 4 Ne pas laisser la cuisini re sans surveillance lors de la cuisson 5 Toujours utiliser les articles de cuisson et les ustensiles appropri s au type et la quantit d aliments pr par s 6 Utiliser l appareil seulement pour l usage auquel le fabricant l a destin 7 Avant l entretien courant couper l alimentation lectrique au tableau de distribution principal et verrouiller ce dernier si possible pour viter une mise en marche accidentelle 8 Nettoyer les ventilateurs fr quemment 35 Que faire en cas d un incendie de graisse sur la cuisini
56. ment la hotte afin d en v rifier le fonctionnement avant de proc der l installation finale Retirer la pellicule protectrice de la hotte s il y a lieu Lors d une installation sous un cabinet ajouter des fixations de bois d au moins 4 pouces de large non inclus sur chaque c t Voir Photo 2 Mesurer et pr voir un acc s pour des fils lectriques sous le cabinet Couper le conduit d chappement selon la taille du tuyau de d charge Voir Photo 3 Conduits Photo 2 6 pouces rond 7 pouces rond 3 1 4 po x 10 po Photo 3 40 Installation de la hotte AVERTISSEMENT S il faut d placer une cuisini re lectrique pour installer la hotte couper d abord l alimentation lectrique cette cuisini re par le tableau de distribution principal COUPER LE GAZ AVANT DE D PLACER UNE CUISINI RE A GAZ Perforer les trous de d cochage sur la hotte tel qu indiqu la Photo 4 Si n cessaire placer les fils lectriques pour qu ils passent au travers de la perforation de 1po de diam tre situ sur le dessus ou l arri re de la hotte Veuillez vous r f rer la Photo 5 En utilisant les r f rences de la Table 1 et les mesures la Page 53 centrer la hotte capuchon en place au dessous du cabinet et vis vis le devant du cabinet Trou 1po de diam tre Photo 4 Photo 5 Passer les fils lectriques au travers de l ouverture d acc s des cabinets Ins rer les vis en non
57. mme indiqu la Photo 17 Vis de montage n Photo 16 Photo 17 2 Aligner le support de montage avec les deux vis sur le mur et fixer la hotte en la hotte en place AVERTISSEMENT ASSUREZ VOUS QUE LA HOTTE EST BIEN FIX E AVAN T DE LA RELACHER 45 Installation avec couvre conduits 3 Rep rer la position de la fixation pour couvre conduit Utiliser comme r f rence l indication E de la Table 2 et le mesures Page 53 54 Attacher de fa on s curitaire la fixation pour couvre conduit l aide de deux vis non fournies R f rez vous la Photo 18 NOTE la doublure du couvre conduit masquera la fixation Utiliser des conduits d aluminium ou d acier pour connecter la sortie arri re la canalisation Utiliser un ruban adh sif en toile pour sceller tous les joints et ainsi assurer une parfaite tanch it Brancher les fils lectriques Voir la section Branchement des fils lectriques la Page 48 Glisser la doublure du couvre conduit environ 2 pouces avant d introduire le couvre conduit entier Voir la Photo 19 Photo 18 Photo 19 7 Ajuster la hauteur de la doublure int rieure du couvre conduit a la fixation du couvre conduit S curiser la doublure int rieure du couvre conduit avec deux 4x8 mm vis fournies tel comme indiqu la Photo 20 Attacher ensemble Photo 20 8 Attacher la doublure ext rieure du couvre conduit l adaptateur d chappement multi conduits de
58. nice los cables el ctricos de modo que corran a trav s del agujero de 1 de di metro en la parte superior o en la parte posterior de la campana Consulte la Figura 12 4 Utilizando las referencias en la Tabla 1 y las medidas en la P gina 84 centre la campana en su lugar debajo del gabinete y nivele con el frente del gabinete 5 Coloque el tornillo no incluido en el centro exacto de cada agujero preperforado Aseg rese que todos los tornillos est n en su lugar antes de apretarlos PRECAUCION ASEG RESE QUE LA CAMPANA EST FIJA ANTES DE SOLTARLA Agujero de 1 de Di metro Figura 12 Instalaci n de la Red de Conductos 6 Utilice un tubo de aluminio o acero para conectar el escape pl stico ubicado en la parte posterior de la campana a la red de conductos Utilice cinta de aislar para asegurar y hermetizar todas las uniones 75 INSTALACI N INDEPENDIENTE VENTILACI N SUPERIOR Esta instalaci n s lo aplica con la compra de una cubierta de conductos Preparaci n antes de la Instalaci n NOTA PARA EVITAR CAUSAR DANOS A SU CAMPANA EVITE QUE DESECHOS PENETREN EN LA RENDIJA DE VENTILACION Decida la ubicaci n para colocar el conducto de ventilaci n de la campana hacia el exterior Consulte la Figura 13 Un ducto de escape recto y corto permitir que la campana trabaje con m s eficiencia Intente evitar tantas conexiones codos y ductos largos como sea posible Esto podr a reducir el rendimiento de la campana
59. not slip between motor or any moving parts to prevent any damage Final Assembly Figure 30 1 Place baffle filters underneath the hood Refer to Figure 30 OPERATING INSTRUCTIONS This KOBE hood is equipped with four electronic controls with 10 second standby startup amp 30 second delay shutoff two powerful centrifugal turbine impellers with baffle filters and bright 12 volt 20 watt halogen lights The four electronic controls are Light Control Speed Control A Speed Control B and the Power Control On Off Refer to Figure 31 Light Control Power Control Speed Control A Speed Control B Cycle through Low Medium Cycle through Low QuietMode High High QuietMode Medium Figure 31 TURN ON e Press Power Control On Off button once Note If any control button is not pressed within 10 seconds power will be automatically turned off e The hood will start on Low speed Each press of the Speed Control button will cycle through the various speeds Press Speed Control A button to cycle from Low Medium High or QuietMode Press Speed Control B button to cycle from Low QuietMode High or Medium Note Speed Control A or B will operate both fans These two speed buttons vary the speed quicker e Press Light Control button to turn halogen light on TURN OFF Press Power Control On Off button once panel lights will flash and power will be completely shut off afte
60. o 5 NO permita que soluciones de sal desinfectantes blanqueadores o compuestos de limpieza permanezcan en contacto con el acero inoxidable por periodos de tiempo prolongados Muchos de estos compuestos contienen qu micos que podr an ser perjudiciales Enjuague con agua despu s del contacto y seque con un pa o limpio libre de pelusas Para limpiar el Filtro Deflector Conductos de Aceite PRECAUCI N DRENE EL ACEITE DEL FILTRO DEFLECTOR Y CONDUCTO PARA ACEITE ANTES QUE ESTE SE DERRAME 1 Remueva todos los filtros deflectores y el conducto para aceite 2 Utilice una esponja y l velos con agua tibia jabonosa S quelos completamente antes de volverlos a colocar en su lugar Nota Los Filtros Deflectores pueden lavarse en el tramo superior del lavaplatos autom tico 84 Para Reemplazar el Foco PRECAUCI N LA UNIDAD DE LA L MPARA DE HAL GENO PODR A ESTAR CALIENTE ESPERE HASTA QUE SE ENFR E NOTA NO TOQUE LA L MPARA DE HAL GENO CON LAS MANOS DESPROTEGIDAS PUES PODRIA CAUSAR SOBRECALENTAMIENTO Y REDUCIR EL TIEMPO DE VIDA DE LOS FOCOS Foco de Hal geno Cu a L mpara Destornillador 12V 20W Le Hal gen llos de Cabeza Vidrio de la L mpara AN de Hal g IN 1 Aseg rese que todos los controles se encuentren APAGADOS y que la campana de extracci n se encuentre desconectada 2 Coloque el destornillador de cabeza plana en la ranura localizad
61. o F Panneau pare claboussures 2 30 B C D E F lt gt du couvre conduit vendue s par ment G Couvre conduit 1 Ensemble de vis 1 I Support de fixation du couvre conduit 1 J Support de fixation hotte 1 G Couvre conduit int rieur Couvre conduit ext rieur d B 3 16po x 3 8po 9 pcs 4x 8 mm 8 pcs S Cales de Caoutchous 2 pcs e POUR DE PLUS AMPLES RENSEIGNEMENTS VEUILLEZ VISITER NOTRE SITE WEB www KOBERangeHoods com OU COMMUNIQUER AVEC KOBE RANGE HOODS AU 626 775 8880 37 INSTALLATION VEUILLEZ LIRE ENTI REMENT LES INSTRUCTIONS AVANT DE PROC DER Calcul avant Installation Calculer la longueur de l installation avant d installer la hotte Toutes les mesures sont donn es en pouces HOTTE INSTALL E SOUS UNE ARMOIRE TABLE 1 vue de c t A hauteur du plancher au plafond B hauteur du plancher jusqu au comptoir la surface de cuisson Normalement 36 po C hauteur recommand e entre le dessus du comptoir surface de cuisson jusqu au dessous de la hotte D gagement minimum 27po 30po D hauteur de la hotte E hauteur du cabinet d armoire TABLE 2 vue de c t A hauteur du plancher au plafond B hauteur du plancher jusqu au comptoir la surface de cuis Normalement 36po C hauteur recommand e entre le
62. o de 12 voltios 20 vatios Los cuatro controles electr nicos son Control de Luz Control de Velocidad A ciclos entre Bajo Medio Alto Modo Silencioso QuietMode Control de Velocidad B ciclos entre Bajo Modo Silencioso QuietMode Alto Medio y el Control de Encendido Apagado Consulte la Figura 31 Control de Luz Control de Encendido Control de Velocidad A cr f Cambia entre Baja a allein uio Modo Silencioso QuietMode Alta Media Figura 31 ENCENDIDO e Oprima el Control Encendido Apagado una vez Nota Si no se oprime ninguno de los botones de control en 10 segundos la unidad se apagar autom ticamente e La campana iniciar en velocidad Baja Cada vez que oprima el bot n de Control de Velocidad se cambiar n las diferentes velocidades e Oprima el Control de Velocidad A para cambiar de Bajo Medio Alto o Modo Silencioso QuietMode Oprima el Control de Velocidad B para cambiar de Bajo Modo Silencioso QuietMode Alto o Medio Nota Los Controles de Velocidad A o B har n que ambos ventiladores funcionen Estos dos botones de velocidad hacen que la velocidad cambie m s r pido e Oprima el Control de Luz para encender la l mpara de hal geno APAGADO e Oprima el Control de Encendido Apagado una vez las luces del panel titilar n y la unidad se apagar completamente despu s de 30 segundos e Oprima el Control Encendido Apagado dos veces y la unidad se apagar inmediat
63. or NO ventile el aire del escape en espacios cerrados entre paredes ticos espacios de acceso debajo de pisos o garajes NOTA Esta garant a no es v lida sin un recibo de un agente autorizado o si la unidad se ha da ado debido al maltrato mala instalaci n uso inadecuado abuso negligencia o cualquier otra circunstancia que se encuentre fuera del control de los agentes autorizados de KOBE RANGE HOODS Cualquier reparaci n que se realice sin la supervisi n de los agentes autorizados de KOBE RANGE HOODS anular la garant a autom ticamente KOBE RANGE HOODS no se har responsable por cualquier da o a la propiedad personal o inmobiliario ni por las lesiones f sicas que se hayan causado ya sea directa o indirectamente por la campana de extracci n ADVERTENCIA PARA REDUCIR EL RIESGO QUE OCURRAN LESIONES NO G f D PERSONALES EN CASO DE UN INCENDIO CAUSADO POR LA GRASA ACUMULADA EN LAS HORNILLAS DE LA ESTUFA Mantenga limpios todos 105 ventiladores deflectores separadores filtros conductos aceite recipientes para aceite y las superficies saturadas con grasa No deber permitirse que la grasa se acumule en el ventilador deflector separador filtro conducto de aceite recipiente para aceite Siempre ENCIENDA el extractor cuando cocine Utilice las configuraciones altas en la estufa SOLAMENTE cuando sea necesario No deje la estufa sin supervisi n mientras est cocinando Siempre utilice utensilios de
64. p www KOBERangeHoods com This KOBE hood is made for use in the USA and CANADA only We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country Using a KOBE hood overseas is at your own risk and will void your warranty Cette hotte KOBE est fabriqu e pour usage aux tats Unis et au Canada seulement Il n est pas recommand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propre risque et la garantie sera annul e Esta campana de extracci n KOBE ha sido fabricada para ser utilizada nicamente en EE UU y CANADA No recomendamos la utilizaci n de esta campana en el extranjero debido a que la fuente de energ a podr a no ser compatible y podr a violar el c digo el ctrico de dicho pa s Utilizar una campana KOBE en el extranjero ser a su propio riesgo y anular la garant a VER 091210 Information subject to change without notice
65. r if any Cut the multi vent exhaust according to the size of the venting pipe Refer to Figure 15 WALL STUDS 7 Round Vent 3 1 4 x 10 Vent Figure 15 If necessary attach two rubber stands provided with two 4x8 mm screws provided to the back of the hood Attach the hood mounting bracket to the back of the hood with nine 3 16 x 3 8 screws provided as shown in Figure 16 Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE 1 Using references on Table 2 and measurements on Page 22 23 mark the leveling point of the hood Position two mounting screws not provided on the wall leaving 1 8 away from the wall as shown in Figure 17 Mounting Screws Figure 16 Figure 17 2 Align hood mounting bracket to the two screws on the wall and hook hood into place Tighten screws to secure hood to the wall CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING 13 3 Duct Cover Installation Mark the position of the duct cover mounting bracket Use reference E from Table 2 and measurements on Page 22 23 Attach and secure duct cover mounting bracket with two screws not provided Refer to Figure 18 NOTE Inner duct cover will cover the duct cover mounting bracket Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above Use d
66. r 30 seconds OR Press Power Control On Off button twice all power will be shut off immediately e If only the lights are on pressing Power Control On Off button once will turn power off after 30 seconds 19 MAINTENANCE For optimal performance clean the range hood surface and baffles regularly To Clean Hood Surface CAUTION NEVER USE ABRASIVE CLEANERS PADS OR CLOTHS Regular care will help preserve its fine appearance 1 Use only mild soap or detergent solutions Dry surfaces using soft cloth 2 f hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner Caution Do not leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean lint free cloth To Clean Baffle Filter Oil Tunnel CA
67. r Mounting Bracket C1 0221 1530 05 Screw 3 16 x 3 8 C1 0707 0001 06 Rubber Stand C1 0511 0382 07 Screw TS 4 x 8 mm C1 0708 0006 25 CH2230SQB CH2236SQB MODEL NO DUCT COVER a o e N N I O CH2230SQB CIRCUIT DIAGRAM MODEL 22305 CH2236SQB R CAPACITOR 2 2 3 5 3 5uF 250V 120V AC ELLO GROUND Gow S gt lt 2 a ROWN 815 BRO 2 2 BLUE TRANSFORMER ET 2V B sc 55 ER 37 20 5 2 gt n YELLOW GREEN BLUE WHITE BLUE BLUE YELLOW GREEN BLUE BLACK BROWN RED ORANGE 27 TROUBLE SHOOTING Issue Possible Cause Solution After Installation both motors and lights are not The power is not on Make sure the circuit breaker and the unit s power is ON Use a voltage meter to check the power supply The wire connection is not secure Check and tighten wire connection working The control panel and processor board Check wire continuity from control panel to processor wiring are disconnected board The motor transformer is defective Check the power input and power output on the motor transformer If its needed replace the motor transformer The control panel and processor board is Replace the control panel or processor board defective Lights are The motor s is defective Replac
68. rant a usted ser responsable por todos los gastos asociados con el servicio solicitado incluyendo piezas mano de obra transporte viaje y cualquier otro gasto relacionado con la solicitud de servicio Para tener derecho al servicio de garant a usted debe 1 Tener el comprobante de compra original 2 Ser el comprador original del producto 3 Tenga el n mero de modelo 4 Tenga el n mero de serie 5 Tener una descripci n de la naturaleza de cualquier defecto en el producto o pieza PARA SOLICITAR EL SERVICIO DE GARANT A POR FAVOR CONTACTE EL CENTRO DE SERVICIO DE KOBE RANGE HOOD CENTRO DE SERVICIO DE KOBE Tel 1 855 800 5623 E mail kobe adcoservice com 94 FORMULARIO DE INFORMACION DE GARANTIA Llene los espacios en blanco y guarde este papel con la factura original en un lugar seguro para el prop sito de servicio en el futuro 1 Fecha de compra 2 No de Modelo 3 No de Serie Para obtener el servicio de garant a o compra de repuesto de piezas p ngase en contacto con KOBE Service Center Toll Free 1 855 800 KOBE 5623 Email kobe 2adcoservice com Para reportarse del problema p ngase en contacto con Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com Para informaciones del producto Toll free 1 877 BUY KOBE 289 5623 Email info koberangehoods com Sus notas 95 KOBE Range Hoods 11775 Clark Street Arcadia CA 91006 USA htt
69. ri re avec un soutien additionnel pour une installation s curitaire En utilisant les r f rences la Table 2 et les mesures la Page 53 54 r gler la hauteur du soutien additionnel R f rez vous la Photo 14 Pr paration de la hotte avant installation Fixer temporairement la hotte afin d en valuer le fonctionnement avant de proc der l installation permanente Retirer le film protecteur de la hotte et du couvre conduit D couper l ouverture multi conduit selon la taille des tuyaux d chappement R f rez vous la Photo 15 Conduits Poteaux de cloison Photo 14 rem 6 pouces rond 7 pouces rond 3 1 4 po x 10 po Photo 15 44 Si n cessaire fixer les deux fixations fournis en caoutchouc en compagnie des deux vis 4x8 mm fournies l arri re de la hotte Fixer le support de montage au dos de la hotte avec l aide des neuf 3 16po x 3 8po vis fournies tel qu indiqu la Photo 16 Installation de la hotte AVERTISSEMENT S il faut d placer une cuisini re lectrique pour installer la hotte couper d abord l alimentation lectrique cette cuisini re par le tableau de distribution principal COUPER LE GAZ AVANT DE D PLACER UNE CUISINI RE A GAZ 1 En utilisant en r f rence la Table 2 et les mesures la Page 53 54 rep rez le point de nivellement de la hotte Installer deux vis de fixation non fournies sur le mur laissant 1 8po d espace par rapport au mur co
70. rsar el gas Si a n as siente olor a gas llame a la Compa a de Gas y al Departamento de Bomberos inmediatamente PRECAUCI N Solamente para ventilaci n general No utilizar para eliminar materiales y vapores peligrosos o explosivos Para reducir el peligro de incendio utilice solamente una red de conductos met licos Necesita aire suficiente para la combusti n y eliminaci n de gases por medio del conducto de ventilaci n chimenea para prevenir la explosi n de flujo de aire en retroceso Siga las directrices y est ndares de seguridad del fabricante del equipo de calefacci n tales como aquellos publicados por la Asociaci n de Protecci n contra Incendios National Fire Protection Association NFPA y la Sociedad Americana de Ingenieros en Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades normativas Activar cualquier interruptor podr a causar una explosi n o ignici n Debido al tama o y peso de esta campana de extracci n se recomienda que la instalaci n sea realizada por dos personas 4 ADVERTENCIA RIESGO DE ELECTROCUCI N Puede resultar en lesiones serias o TA la muerte Desconecte el aparato del suministro el ctrico antes de darle servicio Si estuviera equipado con ste el foco fluorescente debido a que contiene peque as cantidades de mercurio deber reciclarse o desecharse seg n los C digos
71. s si hubiera alguna Remuewva los tornillos de la cubierta de ventilaci n posterior y corte sobre la l nea de la cubierta interna de ventilaci n posterior Consulte la Figura 23 Corte el orificio de la cubierta de ventilaci n posterior y regrese al otro lado Consulte la Figura 24 TAPA DEL TECHO ENTRAMADO DE LA PARED copo REDONDO Figura 21 osos Bl Cubierta de Ventilaci n Cubierta Interna Cubierta de Posterior Ventilaci n Revertida Posterior Figura 23 Figura 24 19 Si fuera necesario coloque dos bases de goma incluidas con dos tornillos de 4x8 mm incluidos a la parte posterior de la campana Coloque el soporte de montaje de la campana a la parte posterior de la misma con nueve tornillos de 3 16 x 3 8 incluidos como se muestra en la Figura 25 Instalaci n de la Campana PRECAUCI N Si fuera necesario mover la estufa para instalar la campana desconecte la electricidad en la caja el ctrica principal si es una estufa el ctrica APAGUE EL GAS ANTES DE MOVER UNA ESTUFA DE GAS 1 Utilizando las referencias en la Tabla 2 y las medidas en las P ginas 84 85 marque punto de nivel de la campana Posicione dos tornillos de montaje no incluidos en la pared dejando un espacio de 1 8 lejos de la pared como se muestra en la Figura 26 Tornillos de Montaje Figura 25 Figura 26 2 Utilice un tubo de aluminio o acero para conectar el orificio de escape ubica
72. s de garantie des frais suppl mentaires peuvent s appliquer et comprennent mais ne sont pas limit s e Les frais de service de voyage technicien si le centre de service demand est de 30 miles de la zone de service autoris par KOBE D penses d exp dition des pi ces Non installation d un produit d fectueux et installation d appareil de remplacement UN AN DE GARANTIE LIMIT E POUR PIECES SUR LES SERIES KOBE Brillia Pendant un an compter de la date de votre facture originale chez un concessionnaire agr KOBE nous vous fournirons gratuitement les pi ces pour remplacer celles qui ont chou en raison de d fauts de fabrication C est notre seule discr tion choisir de r parer ou de remplacer les pi ces d fectueuses ll est de votre seule responsabilit pour tous les co ts de main d uvre associ es cette garantie Exclusions de la garantie Cette garantie ne couvre pas y compris mais sans s y limiter ce qui suit a Une mauvaise installation b Toute r paration alt ration modification non autoris e par KOBE c Alt ration de conduit ou de modification et connexion d Mauvaise alimentation lectrique tension ou c blage e L entretien normal et les services requis pour le produit f Les pi ces consommables comme les ampoules et les filtres de carbone g Utilisation non conforme du produit qui n etait pas pr vue comme l utilisation commerciale utilisation l ext rieur et multi usage fam
73. strador Est ndar 36 C Altura Preferida de la Superficie del Mostrador a Parte Inferior de la Campana M nimo de 27 a 30 D Altura de la Campana E Altura del Gabinete Cabinet PARA INSTALACI N INDEPENDIENTE CON CUBIERTA DE CONDUCTOS OPCIONAL TABLA 2 A Altura del Piso al Techo B Altura del Piso a la Superficie del Mostrador Est ndar 36 C Altura Preferida de la Superficie del Mostrador a Parte Inferior de la Campana M nimo de 27 a 30 D Altura de la Campana E Altura de la Cubierta de Conductos F D F Altura de Instalaci n de la Campana A B C ADVERTENCIA DE SEGURIDAD LA CAMPANA PODR A TENER EXTREMOS SUMAMENTE FILOSOS FAVOR DE UTILIZAR GUANTES PROTECTORES SI VA A RETIRAR CUALQUIER PIEZA PARA INSTALAR LIMPIAR O DARLE SERVICIO NOTA TENGA MUCHO CUIDADO AL UTILIZAR UN DESTORNILLADOR EL CTRICO PODR A CAUSAR DANOS A LA CAMPANA ndice de Instalaci n DEBAJO DEL GABINETE Ventilaci n Superior pp 69 KA BG EE 71 INDEPENDIENTE Ventilaci n S perior reiese ia ESA a ere CE E ERR eat 73 Ventilaci n Posterior rore ecco o cow a LN ERE ad aaa 76 71 INSTALACI N DEBAJO DEL GABINETE VENTILACI N SUPERIOR Preparaci n antes de la Instalaci n NOTA PARA EVITAR CAUSAR DANOS A SU CAMPANA EVITE QUE DESECHOS PENETREN EN LA RENDIJA DE VENTILACION Decida la ubicaci n para colocar el
74. t short venting run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood Temporarily wire the hood to test for proper operation before installing Peel protective film off the hood if any For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not included on each side Refer to Figure 7 Measure and create access opening for electrical wires under the cabinet or access opening for the electrical wires at the rear of the hood Remove the screws on the vent cover rear and cut along the line of the inner vent cover rear opening Refer to Figure 8 Cut the vent cover rear opening and reverse to the other side Refer to Figure 9 Reattach the vent cover rear Inner Vent Reversed Cover Rear Vent Cover Rear Figure 8 Figure 9 Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE 1 2 Puncture the knockout holes on the hood as shown in Figure 10 Unscrew and remove the multi duct exhaust Replace with D vent cover top Refer to Figure 11 Figure 10 Figure 11 If necessary arrange the electrical wires to run through the 1 diameter hole on the top or the rear of the hood Refer to Figure 12 Using references on Tabl
75. the hood and the duct cover if any Remove the screws on the vent cover rear and cut along the line of the inner vent cover rear opening Refer to Figure 23 Cut the vent cover rear opening and reverse to the other side Refer to Figure 24 WALL STUDS Inner Vent Cover Rear Reversed Vent Cover Rear Figure 23 Figure 24 If necessary attach two rubber stands provided with two 4x8 mm screws provided to the back of the hood Attach the hood mounting bracket to the back of the hood with nine 3 16 x 3 8 screws provided as shown in Figure 25 Hood Installation CAUTION If required to move the cooking range to install the hood turn OFF the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE 1 Using references on Table 2 and measurements on Page 22 23 mark the leveling point of the hood Position two mounting screws not provided on the wall leaving 1 8 away from the wall as shown in Figure 26 Mounting Screws Figure 25 Figure 26 2 Use aluminum or steel pipe to connect the exhaust opening at the rear of the hood to the ductwork Use duct tape to make all joints secure and air tight 3 Align hood mounting bracket to the two screws on the wall and hook hood into place Tighten screws to secure hood to the wall CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING 16 Duct Cover Installation 4 7 8 Mark the position of the du
76. to alguno las piezas para reemplazar los que ha fallado debido a defectos de fabricaci n Es nuestra entera discreci n de optar por reparar o sustituir las piezas defectuosas Es solo su responsabilidad por todos los gastos laborales asociados con esta garant a Exclusiones de la garant a Esta garant a no cubre incluyendo pero no limitado a lo siguiente Una instalaci n incorrecta Cualquier reparaci n alteraci n modificaci n no autorizada por KOBE Alteraci n del conducto modificaci n y conexi n Incorrecta corriente el ctrica voltaje o cableado El mantenimiento normal y servicios que son requeridos por el producto Piezas de consumo como bombillas y filtros de carbono Uso inadecuado del producto que no est destinado a como el uso comercial uso al aire libre y el uso multifamiliar El desgaste normal Chips ara azos o abolladuras por abuso o mal uso del producto Los da os causados por accidentes incendios inundaciones y otros fen menos naturales a up V Ta 93 k Los gastos incurridos por servicios situado fuera del rea de servicio designado Las compras a distribuidores no autorizados m Costos de eliminaci n de productos defectuosos e instalaci n asociados con el producto de reemplazo Si determinamos que las exclusiones de garant a que aparecen arriba son aplicables o si usted no puede proporcionar toda la documentaci n necesaria para el servicio de ga
77. to enhance the performance house of the range hood by creating a sufficient make up air Obstacle blocking the pipe work Remove all obstacles from the duct work The pipe size is smaller than the Change the ducting according to the suggested pipe size manufacture suggestion Cold air is The pipe connection is not properly Check the pipe installation coming into the home sealed The damper is not properly installed or is missing from the installation Check the damper installation The damper is not installed By installing the damper it will help to eliminate air backflow 28 WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods referred to herein as we or us warrants to the original purchaser referred to herein as you or your all products manufactured or supplied by us to be free from defect in workmanship and materials as follows TWO YEAR LIMITED WARRANTY FOR PARTS AND LABOR ON KOBE PREMIUM SERIES For two years from the date of your original invoice from a KOBE authorized dealer we will at our sole discretion choose to repair or replace the product free of charge that failed due to manufacturing defects It is your sole responsibility to ensure the product is readily accessible for the service technician to perform repairs The service technician will not under any circumstance remove alter or modify any fixture built around and or connected to the product to gain
78. uct tape to make all joints secure and air tight Connect electrical wires Refer to Wiring to Power Supply on Page 17 Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood Refer to Figure 19 Figure 18 Figure 19 Adjust the height of the inner duct cover to the duct cover mounting bracket Secure the inner duct cover with two 4x8 mm screws provided as shown in Figure 20 Attach Together Figure 20 Fasten outer duct cover to multi vent exhaust on the hood with four 4x8 mm screws provided 14 WALL MOUNT INSTALLATION REAR VENT This installation only applied with the purchase of a duct cover Preparation before Installation NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ENTERING THE VENT OPENING Decide the location of the venting pipe from the hood to the outside Refer to Figure 21 A straight short venting run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood Use duct tape to seal the joints between pipe sections If necessary prepare back wall frame with cross framing lumber for secure installation Using references on Table 2 and measurements on Page 22 23 decide the level of the lumber Refer to Figure 22 Hood Preparation before Installation Temporarily wire the hood to test for proper operation before installing Peel protective film off
79. uctos CH1120DC 12 15300 51 04 Soporte de Montaje de la Cubierta de Conductos C1 0221 1530 05 Tornillo 3 16 X 3 8 C1 0707 0001 06 Base de Goma C1 0511 0382 07 Tornillo TS 4 X 8 mm C1 0708 0006 CH2230SQB 22365 MODELO NO CUBIERTA DE CONDUCTOS CH2236SQB a o ei N N T O 90 CH2230SQB 22365 DIAGRAMA DE CIRCUITO MODELO NO INZV e a lt Se oro 23 Eo 34vo 7 22 VINVUVN 8 orou o SE e TVYLNIN 14405 120V GROUND E OONV1E INSTRUCCIONES IMPORTANTES DE SEGURIDAD Problema Posible Causa Soluci n Despu s de la No est encendido Aseg rese que el interruptor de circuitos y la Instalaci n unidad se encuentren encendidos Utilice un ninguno de los motores ni las luces est n funcionando medidor de voltaje para verificar la energ a de entrada La conexi n de cables no est bien sujeta Verifique y ajuste la conexi n de cables El cableado del panel de control y la placa de procesador est desconectado Verifique la continuidad del cable desde el panel de control hasta la placa de procesador El transformador del motor est defectuoso Verifique la entrada y salida de la corriente el transformador del motor De ser necesario reemplace el transformador de
80. uil bien balanc e La hotte n est pas assez bien serr e V rifiez l installation de la hotte serrez le support de fixation Le moteur L ampoule de la lampe halog ne est Essayez l ampoule de lampe d fectueuse sur fonctionne d fectueuse une douille qui fonctionne Si l ampoule ne fonctionne mais pas les toujours pas remplacez la lumi res Le c blage de la lampe n est pas assez V rifiez le c blage au complet partir de la carte serr processeur jusqu au transformateur puis jusqu au boitier Le transformateur de la lumi re est V rifiez l entr e de courant et la sortie de courant du d fectueux transformateur de lampe Si n cessaire remplacez le transformateur de lampe Le panneau de commande ou la carte Remplacez le panneau de commande ou la carte processeur est d fectueux processeur La hotte de La hotte de cuisine est install e hors des Ajustez le d gagement entre la hotte de cuisine cuisine limites recommand es par le fabricant et la table de cuisson pour qu il soit de 27 30 ne ventile pas Pour une hotte de cuisini re sur lot le d gagement correctement entre la hotte de cuisine et la table de cuisson est de 30 36 I n y a pas d air d appoint l int rieur dela Ouvrez la fen tre pour am liorer la performance maison de la hotte en cr ant suffisamment d air d appoint Un obstacle bloque la canalisation Enlevez tous les obstacles de la canalisation La canalisation est plus petite que la Changez
81. ulti Conductos C1 0507 1530 2 Cubierta de Ventilaci n Superior B101 1530 12 3 Cubierta de Ventilaci n Posterior C1 0508 1530 A 4 Marco de la Cubierta de Ventilaci n C1 0508 1530 B 5 Carcasa de la Campana GH223050B 10 10505 CH2236SQB 10 1636A 6 L mpara de Hal geno 12Vatios 20Watts Max C1 0403 0101 7 Unidad de Control C1 0501 0101 8 Panel de Control C1 0404 4001 A 9 Soporte de Control C1 0207 5200 10 Soporte del Transformador C1 0201 1530 11 Transformador Motor C1 0402 A120 08 12 C mara de Aire A C mara de Aire Superior CH2230SQB B C mara de Aire Lateral CH2230SQB A C mara de Aire Superior CH2236SQB B C mara de Aired Lateral CH2236SQB CH2230SQB 13 Transformador Luz CH2236SQB C1 0402 0120 40 14 Condensador C1 0401 0120 01 15 Caja del Panel Procesador C1 0501 0102 16 Panel Procesador C1 0404 4110 B 17 Motor Derecha C1 0301 0120 29B 18 Motor Izquierda C1 0301 0120 29A 19 Impulsor de la Turbina Derecha C1 0251 0880 B 20 Impulsor de la Turbina Izquierda C1 0251 0880 A 21 Sello del Conducto de Aceite C1 0502 0301 22 Conducto de Aceite C1 0502 0102 23 Cubierta Pl stica del Impulsor C1 0251 0001 24 Pantalla de Seguridad C1 0602 0101 25 Filtro Deflector B101 1930 15 26 Carcasa Inferior CH2230SQB B101 4130 09 Cubierta de Conductos Opcional NO DESCRIPCI N MODELO TAMA O PIEZA NO 01 Soporte de Montaje de la Campana C1 0221 1530 02 Tornillos TS 4 x 8 mm C1 0708 0006 03 Cubierta de Cond