1. M Transactional Polbach Consistency MS Exchange 3 VUE in J Snapshot Copy Ser BPO 15 mins RTO 25 F 1 200 EM NE PM Figure 4 4 1 Caution Snapshot QSnap rollback features need 512MB RAM at least Please also refer to RAM certification list in Appendix A 4 4 1 Create snapshot QSnap volume To take a snapshot QSnap of the data please follow the procedures 1 Select Volume config User data volume 2 Choose a UDV to do snapshot QSnap by clicking the button in the Snapshot QSnap GB column it will direct to a setup page The maximum snapshot QSnap space is 2TB which user can setup the space no bigger than 2048GB 3 Setup the size for snapshot QSnap The size is suggested to be 20 of UDV size at least then click confirm It will go back to the UDV page and the size will show in snapshot QSnap column It may not be the same as the number entered because some is reserved for snapshot QSnap internal usage There will be 2 numbers in Snapshot QSnap GB column These numbers mean Free snapshot QSnap space and Total snapshot QSnap space 4 Choose a UDV by clicking the checkbox of the row and then click o Snapshot e 5 A snapshot QSnap UDV is created with the date and time taken snapshot QSnap of the chosen UDV The snapshot QSnap UDV 75 size is the same as the chosen UDV no matter the ac
2. 107 G QLogic QLA4010C setup instructions cea 126 H Installation Steps for Large Volume TB 131 Configuration of SNMP S im ple Network Management Control 141 Chapter 1 RAID introduction 1 1 Features GeViRAID series controller is a high performance RAID controller e Backplane solution P120C N Gigabit LAN x2 to SATA II xN bays RAID controller e Cable solution o P100C N Gigabit LAN x2 to SATA II xN bays RAID controller GeViRAID series controller features RAID 6 ready Snapshot on the box QSnap rollback QCopy remote replication SATA II support with SATA backward compatible N way mirror On line volume expansion and RAID level migration Global dedicated cache configuration by volume S M A R T enabled Support SES Support Microsoft VDS Virtual Disk Service Disk roaming MPIO ready initiator driver support needed MC S ready initiator driver support needed Support iSCSI header and data digest Support CHAP authentication Support Link Aggregation Trunking With proper configuration GeViRAID controller can provide non stop service with a high degree of fault tolerance by the use of GeViIRAID RAID technology and advanced array management features The controller features are slightly different between the backplane solution and cable solution For more detail please contact with your direct sales or email to www geutebrueck co
3. Windows Firewall is blocking incoming network connections escept for the programs and services selected below Adding exceptions allows some programs to work better but might increase your security risk Programs and Services Name J File and Printer Sharing GeviScope server WC Message Queuing z Remote Assistance Edit a Port O Remote Desktop KZ i aii Be Poa KEISER KSEILKEER LAS MEI EARS SEHR tt KEES AE KEES LAS READ R ESR R tee oP eT oa ea ee KEE KEISER KT WE II Sp these setting to open A port through Windows Firewall T ei find the port ar MURR E EE EE EE EE EE DEE EE g d i Ke RR number and protocol consult the documentation for the program or service you e SEA O UPaF Framework GE Name Trap Receiver L Add Program Add Fort Edit Delete EN eeng wi Display a notification when windows Firewall blocks a program eo ICP e UDF What are the nske of allowing exceptions d Wal ane the risks of opening a port Ca Change SCOPE OK Cancel 92 1 1 4 St rung Error ER 192 168 201 150 u 1 3 61 4 1 22274 1 Type 6 101 10 44 54 0970106 a 192 168 201 150 u 1 381 41 222741 Type BE Ir 28 22 09 01 06 ap ee RER EE EE EE ER EELER EE EE EE ER EELER EE RER EE ERR EE EE EE EE EE EE EE EE EE EE EE EEEEE EE EE EE EE EE EE EE EE EE EE EE EEER EE EE EE EE E EE EE EE EE ege E Eer Eet CETTE EE RER EE EE
4. Step 12 Done all volumes have been deleted 3 Enclosure management Enclosure management function allows managing enclosure information including SES config Hardware monitor S M A R T and UPS functions For the enclosure management there are many sensors for different purposes such as temperature sensors voltage sensors hard disks fan sensors power sensors and LED status And due to the hardware characteristics are different among these sensors for different sensors they have different polling intervals Below is the detail polling time intervals Temperature sensors 1 minute Voltage sensors 1 minute Hard disk sensors 10 minutes Fan sensors 10 seconds when there are continuous 3 times of error controller sends ERROR event log Power sensors 10 seconds when there are continuous 3 times of error controller sends ERROR event log 6 LED status 10 seconds u e SES config Access control for SES management Hardware monitor System monitored voltage temperature and battery backup module 5 M A R T Self manitoring analysis and reporting technology for physical disks UPS Uninterruptible power supply Figure 3 7 1 60 3 7 1 SES configuration SES represents SCSI Enclosure Services one of the enclosure management standards Enter SES config function can enable or disable the management of SES Enable e Disable e m Host L UN Permission UDY name E S 0 Read
5. Attach e Snapshot e Create e Delete e Size 7 ee R Snapshot VG CW d No Name CB Status 1 2 3 wi RAID LUN CB name MB i RS 10 f H wae Bur 0 00 0 00 Online C e k men a a BI 14 RAIDS 0 gt R5 100 Attach e Snapshot Create e Delete m Figure F 3 3 Run Microsoft iSCSI initiator 2 03 and check the Initiator Node Name 108 Figure EA 4 Attaching LUN to R5 UDV Input the Initiator Node Name in Host field Volume config Logical unit Attach up RS 1068 Di mer ign 1991 05 com microsoft demo LUN O Es Permission Onead only Read write Figure F 5 5 The volume config setting is done 109 Volume config Logical unit Attach a Detach a LI Host LUN Fermission UDV name Session C qn 1991 05 com microsoft demo 0 Read write R5 1 Session Attach a Detach H Figure F 6 6 Check iSCSI settings The IP address of iSCSI data port 1 is 192 168 11 229 port 2 is 192 168 12 229 for example System config iSCSI NS e Authentication e No Port Aggregation DHCP IP address Netmask Gateway MTU MAC address no no 1500 i LANI 192 168 11 229 de Le e e e E 192 158 11 229 00 13 78 00 02 00 no 192 168 12 254 1500 2 LAN e m 192 158 12 2279 233 239 733 0 m m 00 13 78 00 02 01 Entity name iqn 2004 08 tw com qsan p120c 000a00021 ISNS e Authentication a Figure F 7 7 Add Target Portals on Microsoft iSCSI initiator 2 03 110
6. 4 berpr fen Sie nochmals die Einstellung f r den RAID Level und den RAID PD Slot Falls kein Problem vorliegt klicken Sie auf hne H 5 Auf der nun angezeigten Seite zur Best tigung werden detaillierte RAID Informa tionen angezeigt Falls kein Problem vorliegt klicken Sie auf confirm um die Migration zu starten Der Controller zeigt ein Po pup mit der Meldung Warning power lost during migration may cause da mage of data an um den Benutzer zu warnen Wenn bei der Migration unvor hergesehen der Strom ausfallt besteht ein hohes Sicherheitsrisiko fur die Daten Wurde die Migration gestartet erscheint in Status 3 ein sich bewegendes Recht eck und ein M In Volume Config User Data Volume wird ein M in Status 4 und prozentuale Fortschritt in R angezeigt Name G RO RAID Level RAIDS sl RAID PD slot 12345 Select PD e lt lt Back e Next gt gt e Abbildung 4 2 1 Volume config Volume group Create e Delete a E No Name Total Free PD UDV Status 12 3 RAID GB GB 1 VG RO 8 Online RAID 5 a re SS 3 8 mme Hn Create e Delete D Abbildung 4 2 2 Abbildung 4 2 2 Ein RAID 0 mit 2 Physical Disk wird in einen RAID 5 mit 3 Physical Disks migriert 61 Volume config User data volume Attac snapehcot Craat a Data e Size 8 RK g Snapshot VG CW Ma Name fee Status 1 2 3 2 RAID LUN fon an Taal 8 dp E V y j j d Be et Online wo Tu Ga ie
7. 5 Click 7 User ode all m User M chapi Je chap lt lt Back e Contirm e Figure 3 5 3 8 6 Select CHAP user s which will use Its a multi option can be one or more If choosing none CHAP function can not work 37 Tips After setting CHAP the initiator in host server should be set the same Account Password Otherwise user cannot login 3 5 4 Session Enter Session function it will display iSCSI session and connection information including the following items 1 Host Initiator Name 2 Error Recovery Level 3 Error Recovery Count 4 Detail of Authentication status and Source IP port number Delete e IT No Initiator name TPGT Error recovery level Error recovery count Cia i Iqn 1987 05 com cisco 01 cO4 c4ede54 0x02 0 0 Dil i qn 1987 05 com csco 01 c047c42deS4 0x02 0 D 012 8 qn 1987 05 com csco 01 c047c42de5s4 Ox00 0 0 Delete e Figure 3 5 4 1 Figure 3 5 4 1 iSCSI Session 77 a 77 Pressing the button will display connection s No Initiator IP Initiator name Authentication 0 192 1668 12 212 1qn 1987 05 com cisco 01 c047c42de5s4 no lt lt Back e Figure 3 5 4 2 Figure 3 5 4 2 iSCSI Connection 38 3 5 5 CHAP account Enter CHAP account function to create delete a CHAP account for authentication P100C P120C P150C can create a CHAP account only but P200C can create many CHAP accounts iSCSI contig CHAP account Create User chapi Max
8. 7 O 201c001378a202d9 38 an GFR 1 566 3 g C 201b0013783 202d9 38 zum GFR 1 55b 3 Figure 3 6 7 7 Figure 3 6 7 7 Slot 5 is set as global spare disk Step 5 Done They can be used as iSCSI disks Delete UDVs VG please follow the steps Step 6 Detach LUN from UDV In Volume config Logical unit Attach Detach e Mi Host LUN Permission UDY name Session EI S 0 Fead write WOV R5 1 1 e M ign 1991 05 microsot com idemo 1 Read write UOW R5 2 D Attach 5 Detach e 54 Figure 3 6 7 8 1 Select LUNs by clicking the checkbox of the row then click Detach a 2 Choose Ok 3 Done There will pop up a confirm page Step 7 Delete UDV User Data Volume To delete the user data volume please follow the procedures Select Volume config User data volume Select UDVs by clicking the checkbox of the row Click Delete ur Choose OK Done Then the UDVs are deleted There will pop up a confirm page aS DM Tips When deleting UDV the attached LUN s related to this UDV will be detached automatically too Step 8 Delete VG Volume Group To delete the volume group please follow the procedures 1 Select Volume config Volume group 2 Select a VG by clicking the checkbox of the row make sure that there is no UDV on this VG or the UDV s on this VG must be deleted first 3 Click Delete 7 There will pop up a confirmation page 4 Choose
9. Enable multi path checkbox Then click Advanced Log On to Target Figure F 17 17 Select Target Portal to iSCSI data port 2 192 168 112 229 Then select OK 116 Advanced Settings General IPSec Connect by using Local adapter Microsoft SCSI Initiator Source IF 192 168 12 34 Target Fortal 192 168 12229 3260 CAC Checksum Data digest Header digest CHAP logon information EHAR Helps ensue date security by providing authentication between atarget and an imitator ting ta establish a connection To weil specii the same target EHAR secret thatiwas configured on the target hor thie mitata Username bo 991 05 com microsott qa chrischous laget secret E Perfann meatdal authentication Ta use matua EHAR specii an dinitiator secret on the Initiator Settings page and contqure that secret on the target Figure F 18 18 iSCSI device is connected Click Details iSCSI Initiator Properties General Discovery Targets Persistent Targets Bound Yolumes Devices Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and devices for that target Targets Connected n 2004 08 Dat com gaan p60e bsca0001 amp del SE Log Un Refresh oma um 117 Figure F 19 19 Click Device tab then click Advanced Ta
10. Figure F 27 12 After connected click Details then in the Session tab click Connections 123 iSCSI Initiator Properties ign 2004 08 bet com gean HEI sl edel Connected 1 ar Sppe Figure F 28 13 Choose Round Robin for Load Balance Policy Segmon Gonnecwons ST Eee jon Figure F 29 14 Add Source Portal for the iSCSI data port 2 192 168 12 229 124 Session Gonnectons The round robin policy a tempts to evenly distribute incoming requests to all processing paths 192 166 1 292 Tbe Connie Add Gonnechon Figure F 31 15 Select Local adapter Source IP and Target Portal to iSCSI data port 2 192 168 12 229 Then select OK 125 Advanced Settings Username larget secmek E 17 Bertam mutual authentication Mouse mutual EHe e speciiy ant initiator secretion the initiate settings pagea and c E ara A Hats SEL et or DE beng El Figure F 32 16 The MC S setting is done G QLogic QLA4010C setup instructions The following is the step by step setup of Qlogic QLA4010C 1 Log on the iSCSI HBA Manager and the current state shows No Connection Active 126 SANsurfer iSCSI HBA Manager File Host View Wizard Help Q gt Connect Refresh ISCSIHBA Target information LUN List Mi Host qsan qa222 HBA 0 GLA4010 Rg e Gr Port 0 glogic 1 HBA Model QLA4
11. LUN o D Permission C Read only Read write lt lt Back e Confirm e Figure 3 6 6 1 Figure 3 6 6 1 P200C needs to select Target Multi node the other models Single node do not have such selection Attach e Detach e E Host Target LUN Permission RER Session name iqn 2004 08 tw com qsanip200c 000s6d021 target0 0 Read write UDYV O1 0 IT ign 1991 05 com microsoft demo all 1 Read write UDY 02 0 Attach 3 Detach rn Figure 3 6 6 2 Figure 3 6 6 2 P200C UDV 01 is attached to LUN 0 with every host can access UDV 02 is attached to LUN 1 with only initiator note named iqn 1991 05 com microsoft demo can access The other models do not display Target column e LUN operations description Attach Attach a logical unit number to a user data volume Detach a logical unit number from a user data volume The matching rules of access control are from top to down by sequence For example there are 2 rules for the same UDV one is LUN 0 the other is iqn host1 LUN 1 The other host iqn host2 can login because it matches the rule 1 The access will be denied when there is no matching rule 50 3 6 7 Examples The followings are examples for creating volumes Example 1 is to create two UDVs sharing the same CV global cache volume and set a global spare disk Example 2 is to create two UDVs One shares global cache volume the other uses dedicated cache volume Set a dedicated
12. Log On the target iSCSI Initiator Properties General Discovery Targets Persistent Targets Bound Yolumes Devices Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and devices for that target Targets Connected Details Log On Refresh coed Figure H 15 Figure H 15 Status is Connected the initiator setting is done Step C Initialize Format Mount the disk 136 1 Go to Start gt Control Panel gt Computer Management gt Device Manger gt Disk drives E Computer Management Sl File Action View Window Help e EIER Ise S em a Computer Management Local H 2 System Tools D Ra Event Viewer o KI Shared Folders SE Local Users and Groups a del Performance Logs and Alert g Device Manager Gg HDSF28080PLA380 E Lsap Pl2oc SCSI Disk Device Sg Qsan PI20C Multi Path Disk Device fl Display adapters Figure H 16 Figure H 16 Disk drive status of GeViRAID controller 2 Go to Start gt Control Panel gt Computer Management gt Disk Management it displays a new disk m Computer Management File Action wiew window Help EECHER Computer Management Local volume Layout Type File System status JL Capacity Free Space Free Fault Tolerance Overhead E E System Tools EC Partition Basic FATS Healthy System 19 52
13. Session and CHAP account Entity property iSCSI entity property NIC SCSI portal configuration Node SCSI node configuration Session iSCSI session information CHAP account 93 Add Remove account for iSCSI node Figure 3 5 1 3 5 1 Entity property Select Entity property to view the view the entity name of the controller and setup ISNS IP for iSNS Internet Storage Name Service Add an iSNS server IP address to the iSNS servers list which the iSCSI initiator service can send queries The entity name of P200C can be changed but P100C P120C P150C can not iSCSI config Entity property Entity name Iqn 2004 08 tw com qsan p200c 000a6d016 ISNS IP Figure 3 5 1 1 3 5 2 NIC Select NIC to change IP addresses of iSCSI data ports P200C has four gigabit LAN ports to transmit data but P100C P120C P150C have two ports Each of them must be assigned to one IP address in multi homed mode unless the link aggregation or trunking mode has been selected If any two or more ports are set in link aggregation or trunking mode they will combine to one line displayed in the screen 30 Name LAG LANI no LAN no LANS no LAM4 no Entity name LAG No iA HS MA MA DHCP no na mo ro fa IP address 192 168 11 22 7 192 168 12 227 192 168 13 22 7 192 168 14 227 Netmask 293 202 22 0 el 292 299 200 0 Zam za zog Gateway 192 168 111 254 d
14. Choose Cancel D will change the sector size to 4E The maximun capacity is up to 16 TB This volume can not be Dynamit Disk Figure H 7 Figure H 7 choose OK for 64bit OS choose Cancel for 32bit OS this step will change block size to 4K automatically 133 Z A2 793TB UDV is created Z Volume config User data volume Attach e Create a Delete e Size 3 R YG CY az No Name GB Status 1 2 3 SC RAID LUN Ge MB 1 UbVO1 2793 Online D we HI a e e m e aw Qr 1 RAIDS o VGO1 136 Attach Create D Delete e Figure H 8 a 2793G UDV is created 8 Check the detail information Volume config User data volume More information UDY G Block Size R Strp Snap CM x ID No Name GB Status 1 2 3 KB RAID LUN GB Type VG ID Nanie CV ID MB Config Size Create Time RAID 1021826050 1 UDVO1 2793 Online WB HI I 1 64 6 0 0 00 NORMAL 345494528 VGO1 452869120 136 41 912 1173345654 lt lt Back a Figure H 9 Figure H 9 block size 512B for 64bit OS setting Volume config User data volume More information UDY lock Size R Strp Snap VG CH B 3 ID No Name GB Status 1 2 3 KB RAID LUN GB Type VG ID NAME CV ID MB Config Size Create Time 891804674 1 UDVO1 2793 Online WB HI I 1 64 Gem 0 0 00 NORMAL 345494528 VGO1 452869120 136 41 4096 1173347651 ee a e a a e lt lt Back a Figure H 10 Figure H 10 block size 4K for 32bit OS setting
15. ID JE 2 eae P 192 165 13 254 Ti IB Ji SR 2 ae Gi ign 2004 08 tw com gsan p200c 000a6d021 Figure 3 5 2 1 MTU 1500 1500 1500 1500 Aggregation MAC address Link U0 13 79 36 00 95 up 0U0 13 78 36 00 99 Up 00 13S 7 8 a6 00 8a up 00 13 78 36 00 8b down Aggregation e Figure 3 5 2 1 P200C there are 4 iSCSI data ports Each of them is set to static IP MTU is 1500 Name LAG LAG No LANI no LANZ no Entity name HS HS DHCP no aA no E IP address 192 165 11 216 192 165 12 216 Wetmask 233 223 225 0 ER Gateway 197 168 11 254 192 166 12 254 m iqn 2004 08 tw com qsan p150c 000a8a001 Figure 3 5 2 2 MTU S000 1500 Aggregation MAC address Link 00 13 78 39 00 02 up 00 13 78 39 00 03 up Aggregation Figure 3 5 2 2 P150C there are 2 iSCSI data ports Each of them is set to static IP MTU of LAN is 8000 Wo Port Aggregation 1 LAN d LAN Entity name Figure 3 5 2 3 P120C there are 2 iSCSI data ports MTU is 1500 rno La na DHCP 192 166 11 195 Ei 192 168 12 193 dn IP address Wetmask 233 223 225 0 Gateway 192 168 11 254 192 165 12 254 aoe do oll Ft ign 2004 08 tw com gsan pl20 c 0O00sa2052c Figure 3 5 2 3 31 MTU MAC address 1500 00 13 78 00 07 04 1500 00 13 78 00 0705 Name DHCP IP address Netmask Gateway MITU MAC address L
16. SSH port 28 Figure 3 4 2 1 OU 443 3 4 3 Language Select Language is to set the language shown in Web UI The option Auto Detect will be detected by browser language setting 24 System contig Language Language pee ee m English Simplified Chinese Figure 3 4 3 1 3 4 4 Login config select Login config is to set only one admin and set the auto logout timing The only one admin can prevent multiple users access the same controller in the same time 1 Auto logout The options are 1 Disable 2 5 mins 3 30 mins 4 1 hour The system will log out automatically when the user is no response for a period of time 2 Login lock Disable Enable When the login lock is enabled the system allows only one user to login modify the system settings d System config Login config Auto logout Disable B Login lock ace Enable Figure 3 4 4 1 3 4 5 Password select Password is for changing administrator password The maximum length of admin password is 12 characters System config Password Old password Password Contirm Figure 3 4 5 1 25 3 4 6 Date select Date to set up the current date time and time zone before using or synchronize time from NTP Network Time Protocol server Mow Dome 16 16 18 Time zone Asia Taipel e Setup date and time manually Date 2007 P Time 16 _ ae NTP Server Figure 3 4 6 1 3 4
17. Ten ee Si Windows Firewall Second solution Disable your Windows Firewall Gi Exceptions Unblocking Port 162 _ General Exception Advanced Windows Firewall is blocking incoming network connections except for the programs and services selected below Adding exceptions allows some programs to work Better but might increase your security risk Programs and Services Marne O File and Printer Sharing GeviScope server MT Message Queuing Fdit a Port Remote Assistance Lana want to Use Name Trap Receiver Port number 162 7 Add Program AddPot Edit Display a notification when Windows Firewall blocks a program ZT UNTER UDP what are the risks of opening a port Change scope What ae the risks of allowing exceptions 146 Cancel a Use these settings to open a port through Windows Firewall To find the port number and protocol consult the documentation for the program or Service YOU 1 1 4 Failure Error io 44 54 om 8 ERR ERR RERE ERR EIERE ERR RER ERR RER E ERR E 33 30 0 0106 92 168 0 492 1 68 201 150 ERROR Sat 02 Sep 2006 ER MLET owe Powel Supphil incu of work p z 147 GeViRAID II 7 72350 BA DEEN 19 07 2009 Technische nderungen und Lieferm glichkeit
18. lagel secrek T Beror mutual authentication lause mutual HSE specii an mitiator secret on the Imtatan settings KS SES e a ERS EE E SIE EE Page arid a A E em s Leite S aa SAPIK e D 6 Figur Click OK The status would be Connected Please see Figure D 7 Done it can connect to an iSCSI disk 94 iSCSI Initiator Properties Figure D7 The following procedure is to log off iSCSI device 1 Click Details Please see Figure D 8 Target Properties 95 Figure D 8 2 Check the Identifier which will be deleted 3 Click Log off 4 Done the iSCSI device log off successfully E Trunking LACP setup instructions Here is the step by step to setup Trunking and LACP There are 2 kinds of scenarios for Trunking LACP Please see Figure E 1 Read or Write Read or Write Tronking LACP QSAN P series QSAN P seties 1 Dual ports with Trunking LACP 2 Dual ports with Trunking LACP Via switch read or write in one With 2 hosts one read one write in UDV 2 UDVs at the same time Figure E 1 Network diagram of Trunking LACP The setup instructions are in the following figures 1 Create a VG with RAID 5 using 3 HDDs 96 Volume config Volume group Create e Delete e P Total Free SEH C No Name GB GB PD ZUDWV Status E 2 3 RAID 4 Ra Online RAID 5 L a 5 Ke ge a _ pe Create D Delete e Figure E 2 Creat
19. 223 Secret min 12 max 16 Confirm ee run 12 max 16 Figure 3 5 5 1 Figure 3 5 5 1 P100C P120C P150C press Create to create a CHAP account Create e Delete e User chapi a Create e Delete e Figure 3 5 5 2 Figure 3 5 5 2 P100C P120C P150C create a CHAP account named chap1 P200C supports many CHAP accounts the setting of CHAP account is different from P100C P120C P150C iSCSI config CHAP account Create User chap max 223 Secret eee oid 17 max 16 Confirm eee mn 12 max 16 Node al 1ii 1314 Iqn 2004 08 tw com qsan p200c 000a6d0e1 tar Figure 3 5 5 3 39 Figure 3 5 5 3 P200C press Create to create a CHAP account It can be enabled by a Node name here or empty disabled When selecting empty it can be enabled in iSCSI config NIC page later Create e Delete e m User Node name chapi chap2 IT ign 2004 08 tw com qsan p200c 000a6d021 targeto Create e Delete e Figure 3 5 5 4 Figure 3 5 5 4 P200C create two CHAP accounts named chap1 and chap2 chap2 is enabled by node name ign 2004 08 tw com qsan p200c 000a6d021 target0 3 6 Volume configuration Volume config selection is for the setup of volume configurations including Physical disk Volume group User data volume Cache volume and Logical unit functions Fhysical disk Hard disks to store data Yolu
20. 48 Name LIMW RS 2 VG name WG 5 CV No Dedicated 20 MB Capacity GB 64 Stripe height KB 64 sl Block size B 512 Read Write Write through cache Write back cache Priority High priority Middle priority Low priority Abbildung 3 6 7 10 lt lt Back a Confirm a Schritt 1 W hlen Sie Volume Config User Data Volume Create Schritt 2 Klicken Sie auf Schritt 3 Geben Sie einen UDV Namen ein w hlen Sie einen VG Namen und w hlen Sie ein Dedicated Cache der durch Schritt 1 erstellt wurde Weisen Sie dem UDV eine Gr e zu berpr fen Sie ob die Einstellungen stripe high block size read write mode and set priority Ihren Anforderungen entsprechen und klicken Sie zum Abschluss auf ZE Fertig ein UDV mit einem dedizierten CV wurde erstellt attach ri Shapshot aata a Delete r Size RK Snapshot YG CN No Name em Status 2 3 7 RAID LUN de SECH LAUER e F 0 00 0 00 m A RER a Gei m om ei SE RAID 5 i a a WG 5 40 2 WDY R5 2 6 i n 0 000 060 D P Si Online we 1 5 RAIDS 0 e Vo 20 Attach e Snapshot a Fate amp L E e Abbildung 3 6 7 11 Abbildung 3 6 7 11 Das Global Cache Volume des UDV benannt UDV R5 1 betragt 40 MB UDV R5 2 verwendet ein dediziertes Cache Volume von 20 MB Die Initialisierung von UDV R5 2 liegt bei ungef hr 5 No Size r 1 r 2 a Free 603 MB Abbildung 3 6 7 12 Abbildung 3 6 7 12 In
21. Auswechseln von Baugruppen sowie Wartungsarbeiten beschrieben die zum Betrieb und die Wartung des GeViRAID II notwendig sind Copyright 2008 GEUTEBR CK GmbH Alle Rechte vorbehalten Vielen Dank dass Sie sich f r dieses GEUTEBR CK Produkt entschieden haben F r Fragen senden Sie bitte eine E Mail an info geutebrueck de Wir werden Ihre Fragen so schnell wie m glich beantworten Allgemeines Vielen Dank fiir Ihre Entscheidung ein Ger t aus der GEUTEBRUCK Systemreihe zu erwerben GEUTEBRUCK ist der Systemanbieter fiir komplette Videosicherheits managementanwendungen sowohl 1m analogen wie 1m digitalen Bereich Seit Jahren setzt GEUTEBRUCK Qualit tsma st be in der von Mikroprozessor gesteuerten Sicherheitstechnik Die in unseren Ger ten eingesetzte Technologie ist das Ergebnis der eigenen Entwicklung und ausgew hlter Lieferanten Deshalb st das optimale Zusammenwirken der von GEUTEBR CK angebotenen Komponenten garantiert Inhalt der Anleitung Die Beschreibung zeigt Ihnen wie Sie Ihr GeViRAID I System komplett mit allen Anschl ssen n Betrieb nehmen k nnen Weiterf hrende Dokumentation Nach Anschluss von PC Monitor Tastatur und Maus k nnen Sie die Online Dokumentation durch Aufrufen der online Hilfe in Men leiste in der Betriebssystem Software lesen Bitte lesen Sie unbedingt die elektronisch verf gbaren Beschreibungen um Ihr Ger t vollst ndig in Betrieb nehmen und bedienen zu k nnen 1 1 Siche
22. F gen Sie Target Portals beim Microsoft iSCSI Initiator 2 XX hinzu 102 Abbildung E 14 14 Geben Sie die IP Adresse des iSCSI Data Ports 1 ein 192 168 111 229 wie auf der vorigen Seite angegeben Add Target Portal Abbildung E 15 15 Um sich einzuloggen klicken Sie auf Targets 103 ICSI Initiator Properliers ee e ne Een ue LI 7 Let z ri mmm a LA he a Ay Eu oF Se Abbildung E 16 16 Loggen Sie sich ein LSI Initiator Properbes A E Aa TE en ean eel t Abbildung E 17 17 Klicken Sie auf Advanced 104 Log On bo Target Abbildung E 18 18 Wahlen Sie als Ziel Portal iSCSI Data Port 1 aus 192 168 11 229 Danach klicken Sie auf OK Advanced Sri Microsoft PCS Initiator dad tae pra k cory eye to d L SPT um aT FR Tamm r S gie 1 e pee ce Heads ah ee M BE elt PURE TIE CE SC gut seele Va Jeun i T F _ i Tia rey HOENEN GE Abbildung E 19 19 Die Einstellung ist abgeschlossen 105 E Sl im k akor Fa perlies General Discovery Targets Persistert Targets Boundolumes Devices Select a targ t and cick errecht eee for thet target Click dalak to 288 information aboul the zez connections and devices lu thal Leet SE Ia cen gran p leb3eslllle del Connected Abbildung E Z0 20 Starten Sie Computer Management in Wind
23. IP address Language Login config Password Date Mail SNMP Messenger System log server and view Event log System name System name for identification IP address Internet Protocol IP address for remote administration Language Language preference for WebUl Login config Configuration for auto logout and login lock Password Administrator s password Date System time for event log Alert by e mail SNMP Alert via Simple Network Management Protocol SMMP Messenger Transmits net send and Alerter service messages between clients and servers System log server Alert to remote system log server Eventlog System event log to record critical events Figure 3 4 1 De 3 4 1 System name Select System name to change system name Default system name composed by model name and serial number of this system e g P200C A00001 system config System name System name Pz00c 0000i Figure 3 4 1 1 3 4 2 IP address Select IP address to change IP address for remote administration usage There are 2 selections DHCP Get IP address from DHCP server or static IP The default setting is DHCP enabled User can change the HTTP HTTPS and SSH port number when the default port number is not allowed on host server d System config IP address DHCP Static Address Mask Gateway DNS MAL 10 13 79 00 00 0DB HTTP port HTTPS port
24. JBOD und Multi RAID Hot Spare Festplatte Mehrere Hot Spare Festplatten werden unterstutzt Global spare s Hot Swap Festplatten L fter Netzteil Speicherplatzerweiterung Onli ge ne Fernparametrierung Via serieller Schnittstelle oder Web Browser Fern bertragung per Netzwerkbenachrichtigungen SMTP Pager Alarmbenachrichtigungen Fax Lokal optisch und akustisch eingebauter Lautsprecher Zugriffsschutz Frontklappe abschliessbar L fter 4 x 80 mm Hot Swap 3 x Stromversorgung Netzteile 3x 350 Watt redundant 100 240 VAC 47 63 Hz 10 5 12 6AFCC part 15 Stromversorgung class B EN55022 active power factor correction PF gt 0 95 Betriebstemperatur 0 C 50 C Make 177 8 mm 4HE x 483 mm x 600 mm HxBxT Gewicht 31 kg ohne Festplatten Bestell Nr 5 34741 Inhaltsverzeichnis Kapitel 1 RAID Einf hrung us2200202200020 4 1 1 Eigenschaften essen nee 4 1 2 Begriffserkl rungen cccscceecseceeeeeeeeeeeeeeeeeeneeeeenaes 5 1 3 RAID E f Kapitel 2 Erste Schritte 2202002002002000n0nn0nn0 9 2 1 Vor dem Giant 9 2 1 2 Beschreibung der Bedienelemente 2200 10 2 1 3 Frontseite bei ge ffneter Frontklappe een 10 2 14 Ee ee ee eee eee 10 2 2 ISCSI Einf hrung ME 11 2 3 Management Methoden 12 2 3 1 Web 1 WE 12 232 RS 232 Serieller Eegeregie dees 13 2 3 8 Remote control secure Shell san nne nennen 13 2 4 Geh use nennen nennen nee nne nenne nennen 15 2 4 1 We BE 15 2 4 2 Syst
25. Kernel 2 4 install linux iscsi 3 6 3 tar For Red Hat Enterprise Linux 4 Kernel 2 6 use the build in ISCSI initiator iscsi initiator utils 4 0 3 0 4 in kernel 2 6 9 For Red Hat Enterprise Linux 5 Kernel 2 6 use the build in iSCSI initiator iscsi initiator utils 6 2 0 695 0 7 e15 in kernel 2 6 18 ATTO XTEND 2 0x SAN Mac iSCSI Initiator GlobalSAN iSCSI Initiator v3 0 System Requirements 1 Mac OS X v10 3 5 or later For ATTO initiator it is not free Please contact your local distributor for ATTO initiator iSCSI HBA card Vendor Mogdel O a Se eee GC ASC 7211C PCI X Gigabit 1 port TCP IP offload iSCSI offload NC380T PCI Express Gigabit 2 ports TCP IP offload iSCSI offload QLogic QLA4010C PCI X Gigabit 1 port TCP IP offload iSCSI offload QLogic QLA4052C PCI X Gigabit 2 ports TCP IP offload iSCSI offload 84 For detailed setup steps of Qlogic QLA4010C please refer to Appendix G QLogic QLA4010C setup instructions NIC Vendor Mode D Link DGE 530T PCI Gigabit 1 port HP INC7170 PCI X Gigabit 2 ports NC360T PCI Express Gigabit 2 ports TCP IP offload IBM NetXtreme 1000 T 73P4201 PCI X Gigabit 2 ports TCP IP offload PWLA8490MT PCI X Gigabit 1 port TCP IP offload Intel PWLA8492MT PCI X Gigabit 2 ports TCP IP offload PWLA8494MT PCI X Gigabit 4 ports TCP IP offload GbE Switch Vendr Model Mee WE Del
26. QSnap ist 2 TB d h der Benutzer kann den Platz nicht gr er als 2048 GB einrichten Richten Sie die Gr e f r den Snapshot QSnap ein Die empfohlene Gr e be tr gt mindestens 20 der UDV Gr e klicken Sie dann auf confirm s Sie kommen nun zur ck zur Seite UDV Dort wird in der Spalte Snapshot QSnap die Gr e angezeigt M glicherweise kann diese vom eingegebenen Wert differieren da ein Teil f r die interne Verwendung als Snapshot QSnap reserviert ist In der Spalte Snapshot QSnap GB befinden sich zwei Zahlen Diese Zahlen stehen f r Free Snapshot QSnap Space und Total Snapshot QSnap Space Wahlen Sie eine UDV aus indem Sie die Auswahlbox der jeweiligen Zeile markie ren klicken Sie anschlie end auf SEDI Me Ein Snapshot QSnap UDV wird erstellt mit Angabe von Datum und Uhrzeit wann der Snapshot der gew hlten UDV erstellt wurde Unabh ngig davon wie viel Daten die tats chliche Snapshot QSnap UDV belegt ist die UDV Gr e des Snapshots QSnap dieselbe wie die der ausgew hlten UDV Verbinden Sie eine LUN zum UDV Details hierzu finden Sie in Abschnitt 3 5 6 Fertig Sie k nnen es nun als Disk verwenden Volume config User data volume Attach e Snapshot a Create e Delete a No Name Size Status 1 2 3 pamp eum Snapshot VG CN 501 ap K mare HO L UDW Ra N Online A we i S ER a asi et Er 2 UDW R 1713 10 02 14 17 13 35 Deg v cee BU Dro Bu RAIDO o ch
27. __lArbeitskontkt Relaisi Relais 5 20 ___ Umschaltkontakt LI Mase o O 19 Schalteingang 8 16 6 Schalteingang 7 15 18 Masse LB Schalteingang 6 14 Schalteingang 5 133 6 Schalteingang 4 12 3 Schalteingang 3 1 se o s 2 2 Schalteingang 4 Schalteingang a EE 82 Beispiel Konfiguration des Security Alarm Relais in GeViScope Offnen Sie nun mit einem Doppelklick auf das Icon er GeViScope Setup m Gew frcehe Sri I Fe Ed 7 SA ep E Sg Schritt 1 Verbinden Sie mit einem Server os Loca Schritt 2 Offnen Sie das Ment General Settings Local Dsconnected Schritt 1 Verbinden Sie im Men Connections das GeViScope mit einem Server Schritt 2 ffnen Sie mit einem Klick mit der linken Maustaste das Men General Settings 83 Eingange des GeViScope NOTE TV Schritt 3 Klick auf IO settings Behavioural rules Y Blocking filter 4 Telecontrol Schritt 3 Legen Sie unter lO Settings einen neuen Eingangskontakt an Linksklick auf lO settings Es werden die angemeldeten und konfiguriertenEingange des GeViScope aufgelistet Rechtsklick auf Inputs und mit Add einen neuen Eingang anlegen und im Men Settings unter Name benennen 84 General settings a _ Media channels Vio settings Schritt 4 alarm settings Linksklick auf H Quality profiles er Event settings VF B
28. berpr fen Sie den Initiator Node Namen iSCSI Initiator Properties Ei General Discovery Targets Persistent Targets Bound Vokimes Tevices The SCSI protocol uses the following information Io uniquely identity this inkietor and authenticate targets z Indiator Node Mame vm 1991 05 eren mersch oo chischu To rename the initiator node cick Change _ Chenge To authenticate targets using CHAP click Secret to spachy a CHAF secret e ES To configure IPSec Tunnel Mode addiesses click Tunnel Zus Abbildung E 4 4 Das LUN an ein R5 UDV verbinden Geben Sie in das Hostfeld den Initiator Node Namen ein Volume config Logical unit Attach UD R5 1068 Host bon 199 1 05 com microsoft demo LUM g ca Permission ORaeadony lkand write lt lt Back D Contam Abbildung E 5 99 5 Fertig bitte berpr fen Sie die Einstellungen Volume config Logical unit Attach Detach O Host LUN Permission UDV name Session FI qn 1391 05 c0m marosoft demo i Read write RS 1 Session Attach Detach Abbildung E 6 6 berpr fen Sie die iSCSI Einstellungen Die IP Adresse des iSCSI Data Ports 1 lautet 192 168 11 229 Verwenden Sie Port 1 als Trunking oder LACP Klicken Sie das blaue Quadrat im Aggregation Feld an um Trunking oder LACP festzulegen System config SCSI INS ai Lutneioication No Port Agaregation DHCP IP address Netmask Gateway MT
29. e des Volume 1200 G 80G 15 Der GEVIRAID Controller f hrt je doch berpr fungen durch und findet die effizienteste Ausnutzung der HDDs so dass der Controller nur 200 G HDD die Volume Gr e betr gt 200 G 11 2200 G nutzt Damit ist das Volume gr er und die HDD Kapazit t wird vollst ndig ausgenutzt Schritt 1 W hlen Sie Quick Install dann w hlen Sie den gew nschten RAID Level Siehe dazu auch Abbildung 3 3 1 Nach der Auswahl des RAID Levels klicken Sie auf Der Benutzer wird auf eine andere Seite weitergeleitet und kann eine LUN hier ein richten Next en Quick install Step1 RAID Level RAID O 609 GB iv Thitte Mii To il Lit i ee RAID 0 609 GB J RAID 1 76 GB RAID 3 571 GB RAID 5 571 GB RAID 6 533 GB Abbildung 3 3 1 Schritt 2 Bitte wahlen Sie eine LUN Nummer Die Zugriffskontrolle des Host wird als Platzhalter angezeigt was bedeutet dass jeder Host auf dieses Volume zugreifen kann Auf dieser Seite ist es m glich die Volume Size zu ndern Die maximale Gr Be des Volume wird angezeigt Um die Gr e nochmals einzugeben stellen Sie sicher dass diese kleiner oder gleich der maximalen Gr e des Volume ist Dann klicken Sie auf Next gt gt o Schritt 3 Seite best tigen Klicken Sie auf onim _ wenn alle Einstellun gen korrekt sind Dann wird eine Seite mit dem gerade angelegten User Data Volume wie in Abbildung 3 3 2 a
30. which is an initiator node name for access control or fill in wildcard which means every host can access this volume i Confirm H Choose LUN and permission then click 8 3 Done Attach e Detach e T Host LUN Permission UDY name 5ession E e 0 Read write UDY R5 1 1 o C ign 1991 05 microsot com demo 1 Read write LIDVM HD 3 o Attach e Detach e Figure 3 6 7 6 Figure 3 6 7 6 UDV R5 1 is attached to LUN 0 with any hosts can access UDV R5 2 is attached to LUN 1 with only initiator note named iqn 1991 05 com microsoft demo can access gt d Tips N The matching rules of access control are from top to down by gt sequence Please refer 3 6 6 for details Step 4 Set global spare disk 253 To set global spare disks please follow the procedures Select Volume config Physical disk 2 Select the free disk s by clicking the checkbox of the row then click i Global spares s to set as global spares 3 There is a GS icon shown up at status 1 column Select sl Free disks a Global spares Dedicated spares D Slot WN Size G Status 1 Speed GB name 1 Good e 2007001378340040 38 WG RS5 D ro 1 555 2 Good P E 8 Ro i E 9017001378a202d9 38 VG RS A 1 555 A 3 O 2018001378a202d9 EI VR Bear Fi ro 1 566 J 4 m 20190013783202d9 EI Vu Ri Gage Ai RD 1 555 3 5 m 201a001378a202d9 38 Bonn H as 1 556 Y 6 8 20c4001378000108 38 send A FR 1 5Gb 3
31. 1GB 32 bit or 64 bit data bus width x8 or x16 devices 9 to 11 bits column address Vendor Model with Hynix with Hynix Unigen S UG718D6688LN GJF 1GB DDR 400 with Hynix Unigen UG718D6688LN GJF 1GB DDR 400 with Elpida P150C P200C RAM Spec 240 pin DDR2 533 PC4300 Reg register or UB Unbufferred ECC up to 2GB 64 bit data bus width and also 32 bit memory support x8 or x16 devices 36 bit addressable up to 14 bit row address and 10 bit column address Vendor Mode _ y O SEC A ATP AJ28K72G8BHE6S 1GB DDR2 667 Unbuffered ECC with SEC P AJ28K64E8BHE6S 1GB DDR2 667 Unbuffered non ECC with ATP _ AJ64K72F8BHE6S 512MB DDR2 667 Unbuffered ECC with SEC ATP AJ56K72G8BJE6S 2GB DDR2 667 Unbuffered ECC with Samsung TP Unigen UG64T7200L8DU 6AL 512MB DDR2 667 Unbuffered ECC with Elpida Unigen Unigen UG12T7200L8DU 5AM 1GB DDR2 533 Unbuffered ECC with 83 Dinde bes ee 5AC 1GB DDR2 533 Registered ECC with Elpida Sa 5AM 2GB DDR2 533 UnBuffered ECC with Micron ISCSI Initiator Software OS Software Release Number WS nee arene Microsoft Microsoft iSCSI Software Initiator Release v2 05 Windows System Requirements 1 Windows XP Professional with SP2 2 Windows 2000 Server with SP4 3 Windows Server 2003 with SP1 4 Windows Server 2003 R2 The iSCSI Initiators are different for different Linux Kernels For Red Hat Enterprise Linux 3
32. 22 28 LAN HH 0 1 a a Multicast zeg 2 Stalishes HHON H Quality of Service Abbildung E 10 10 Wahlen Sie LACP aus Falls Trunking ben tigt wird sehen Sie sich bitte Abbildung E 8 an System config 5C5T Aggregalion O Mulb hamed LAND Aggregation O Trunking Lace Ce Back D Con rm Abbildung E 11 101 11 Die Einstellungen befinden sich nun im LACP Modus System config Get Si ISNS Authentication No Port Aggregation DHCP IP address Netmask Gateway MTU MAC address LACH 1500 1 lago n of 192 166 11 229 255 255 255 0 192 168 11 229 a 00 13 78 00 02 00 Entity name 11 2004 08 bw com gsan pl20c P00300021 NS a Authentication Abbildung E 12 12 Erm glichen Sie den Wechsel zur LACP Funktion von Port 21 und 23 Unten stehend folgt ein Beispiel eines Switches 3 Dell OpenManage Satch Admvgniretor Flicrosoft internet Explorer Ble E yew Favorites Tone Hep EE i Search Favertes E E Address hikes 192 168 10 252 Elo ie Dell OpenManage Switch Administrator Support Help About Log Out zer one Ce Ek 192 168 10 252 LAG Membership LAG Membership Network Securl Ports Address Tables GARP Spanning Tree WLAN 2 u 3 Sp 7 8 D 10 14 42 13 14 16 460417 18 19 20 H SS n Za mal fer Sheet neo i rer t Suppo Statistics RM OK Quality of Senice Abbildung E 13 13
33. 6 1 Volume relationship diagram ugeet Aen anne 40 3 6 2 Bee re 41 3 6 3 Vol m GOUD von a ee ee 44 3 6 4 User data volume uk 46 3 6 5 Gacha VOLUME ere 48 3 6 6 Logical unit NUMDET ats anna san augue ae ae bites 49 3 0 1 lune 50 3 7 Enclosure management 60 3 7 1 SESI CONIAUFAUOR ege eegene EE 61 3 7 2 Hardware uer lte EEN 61 3183 Hard drive S M A R T function support 62 3 7 4 DEE 63 3 8 System maintenance ccc cecceeceeceeeseeteeceeteeeaeeseeeeeees 65 3 8 1 Bels lr a acc EE E A A EEA EAEE eeeiecedaemsemeness 65 3 8 2 s 66 310 0 Reset to default E 66 3 8 4 Config iMport EE geegent 67 3 8 5 el elei E 67 3 9 LEO EE 67 Chapter A Advanced operation ccccsccsecseceeceeeeens 69 4 1 Hebuld ann nennen 69 4 2 VG migration and evpansion 71 4 3 UDV Extension 13 4 4 Snapshot QSnap Rollback 1 2 0 cccecceees eee nennen 74 4 4 1 Create snapshot QSnap volume nenn nenn nennen 75 4 4 2 Auto SHAB net e see ee 76 4 4 3 Rolback 77 4 5 QCopy remote replication cccccccecceeeeeeeeeeeeeteeeeeens 78 4 6 DISK POG Ge ee 81 4 7 Support Microsoft MPIO and MC S 81 Appendix E 83 A Certification lest 83 Event notifications cccccccccceceseceeeeseseeeeeeeeeeveeeeeevenenaes 86 C KNOWN Iesues nenn 91 D Microsoft iSCSI Initiator aaaaaenneennennnennenennnnennnn 91 E Trunking LACP setup mstruchons 96 F MPIO and MC S setup instructions
34. 7 LUN vom UDV entfernen Bitte befolgen Sie Schritt 6 des Beispiels 1 um eine LUN zu entfernen Schritt 8 UDV l schen User Data Volume Bitte befolgen Sie Schritt 7 des Beispiels 1 um eine UDV zu l schen Schritt 9 VG l schen User Data Volume 50 Bitte befolgen Sie Schritt 8 des Beispiels 1 um eine VG zu l schen Schritt 10 Freigeben einer dedizierten Spare Disk Um dedizierte Spare Disks freizugeben folgen Sie bitte den folgenden Schritten 1 W hlen Sie Volume Config Physical Disk 2 Wahlen Sie durch Anklicken des Auswahlmen s in der jeweiligen Reihe eine dedizierte Spare Disk aus dann klicken Sie auf ee um die Disk freizugeben Schritt 11 Ein dediziertes Cache Volume l schen Um das Cache Volume zu l schen folgen Sie bitte den folgenden Schritten 1 Wahlen Sie f Volume Config Cache Volume 2 Wahlen Sie durch Anklicken der Auswahlbox in der jeweiligen Reihe ein CV aus 3 Klicken Sie auf Delete In einem Popup Fenster wird eine Best tigung angezeigt 4 Wahlen Sie OK 5 Fertig Das CV wurde gel scht Achtung Das Global Cache Volume kann nicht gel scht werden 51 3 Gehause Management Die Funktion Enclosure Management dient zur Verwaltung der Geh use Parameter einschlie lich SAF TE Config Hardware Monitor S M A R T und UPS Zur Geh use Verwaltung gibt es viele Sensoren die verschiedene Funktionen erf l
35. ASANTEch PANC i OSANTech POC SCSI Disk Device Ee ZEN 2 Abbildung F 20 20 Klicken Sie auf die Registerkarte MPIO w hlen Sie bei Load Balance Policy SKS Robin aus Ibe vice De tails 020900 ana Ox20001 Corne Abbildung F 21 21 Klicken Sie auf Apply 116 Device Details The round robin policy attempts bo evenly distibute Incoming requests to all processing paths pani lta al sah DON Conte Active nis FN oen e 4 00001 O 20001 Conna Active DS FFRES 0s87r 400001 Abbildung F 22 22 Starten Sie Device Manage in Windows Stellen Sie sicher dass das MPIO Device vorhanden ist Dann kann die Disk von IOMETER auf ihre Leistung getestet werden m iria Bi P Device Manages Ele ction ew Help D geg 3 we g rg CHRTSCHOLIS ER Computer E See Disk drives OSANTech PEOC SCSI Disk Device BW ul scsi Dek Device i Dr SC a ag Display adapters o H Foppy disk controllers FAL Floppy disk drives HS IDE ATA ATAPT controllers hoe Keyboards D 7 Mice and other pointing devices D Montos FA Network adapters E W Ports COM amp LPT Di WR Processors SCSI and RAID controllers FAB Sound video and game controllers i System devices Universal Serial Bus controllers Abbildung F 23 Die Setup Anweisungen f r MC S hneln denen von MPIO sehr Den folgenden Abbil dungen k nnen Sie detaillierte Schritte entnehmen F r die Einstellung der Zielseite
36. American Power Conversion Corp UPS Please check detail from http www apc com First connect the system and APC UPS via RS 232 for communication Then set up the shutdown values when the power is gone UPS of other vendors can work fine but they have no such function of communication UPS Type Select UPS Type Choose Smart UPS for APC None for other vendors or no UPS Shutdown When below the setting level the system will Battery Level Shutdown Setting level to 0 will disable UPS function Shutdown lf power failure occurred andthe system can not Delay s return back to the setting value period the system will shutdown Setting delay to 0 will disable the function Select ON when power is gone UPS will shutdown by itself after the system shutdown successfully After power comes back UPS will start working and notify system to boot up OFF will not The status of UPS Detecting Running Unable to detect UPS Communication lost UPS reboot in progress UPS shutdown in progress 64 Po Batteries failed Please change them NOW Battery Level Current percentage of battery level 3 8 System maintenance Maintenance function allows operation of the system functions including Upgrade to the latest firmware Info to show the system version Reset to default to reset all controller configuration values to origin se
37. Blockgr e auf 1 KB 2 KB oder 4 KB erweitern um Volumen von bis zu 4 TB 8 TB oder 16 TB zu unterst t zen da der Host Server nicht LBA Logical Block Addressing 64 Bit unterst tzt Im Fol genden finden Sie detaillierte Installationsschritte Schritt A Konfigurieren Sie Ihr Ziel 1 Gehen Sie zu Volume Config Volume Group erstellen Sie eine VG i Volume config Volume group rsste Delete e kaf Total Free ENZ u Na Maime tE Los PD FUDY Status 1273 RAID Create Delsbe D Abbildung H 1 2 Wahlen Sie den RAID Level und die Disks i Volume config Volume group Create Name LIL RAID Level RAIN RAID PD slot 110111213 14154146 Select PO Abbildung H 2 3 Best tigen Sie die VG Einstellungen volume co Nm Volume group f Create Confirm Create WGDl BAID E RAID width RAID copy RAID row RAID PO slat 9101112131415 16 ee Pack de Continm Abbildung H 3 4 Ein RAID 6 VG wird erstellt 123 volume config Volume group Create Delete o z Total Free a Mame ii fii PD eil Status 1 2 3 RAID l Wool Online RAID 6 a7 gt Create e Delete e Abbildung HA 5 Gehen Sie zu Volume Config User Data Volume erstellen Sie ein UDV f Volume config User data volume Abtsct Create Dielabe gt Size E R B ss VG ey IT Ne Name GB Status E Z i oe RAID SLUIN Ben en APES CH A Cre
38. Client Software ist auf der folgenden Webseite erhaltlich SANtools http www santools com 52 3 7 2 Hardware Monitor Geben Sie die Funktion Hardware Monitor ein um sich Informationen ber die ak tuelle Spannung und Temperatur anzusehen Enclosure management Hardware monitor Item Information 1 5W 1 52 W min 1 44 V max 1 63 V 3 3W 3 28 V min 3 10 V may 3 55 W RoW 5 02 V min 4 80 V max 5 35 V 12W 12 08 V min 11 40 V max 12 80 V A SW 2 54 W min 2 45 W max 2 75 W PSU 5WiBackplane 5 10 V min 4 70 V max 5 35 V PSU 12V Backplane 12 23 V min 11 40 V max 12 80 V PSU 23 3W Backplane 3 31 V min 3 10 V max 3 55 V Daughter Board 43 0 C hyst 0 0 C high 70 0 C PCI ERG 33 5 C hyst 0 0 C high 60 0 C Core Processor 45 0 C hyst 0 0 ICH high 75 0 CH Location 1 Backplane 29 0 C hyst 0 0 C high 45 0 CH Location 2 backplane 29 0 C hyst 0 0 C high 45 0 CH Location 3 Backplane 29 5 C hyst 0 0 C high 45 0 C PSU1 Backplane good PSU2 Backplane good FANI Backplane good FAN Backplane good FANS Backgplane good Auto shutdown E Abbildung 3 7 2 1 Wenn Auto Shutdown ausgew hlt wurde wird das System automatisch herunterge fahren wenn sich Werte f r die Spannung oder Temperatur au erhalb der normalen Grenzbereiche befinden F
39. Dences Select a target and ch Log Ori to acean the slorage deveas for ihal Lengel Chek delai 10 tse infomation aboul Ihe session conmectons and devices for that target automaticaly restore this commection when tha system boots SN l Enable multi path x Gy ale ordi RES Ah esse Branch ota on Op Ser eat ok Tarcal Ac Abbildung H 14 Abbildung H 14 gehen Sie zur Registerkarte Targets klicken Sie auf Refresh und dann auf Log on fiir das Ziel 127 CSI Initiator Properties General Discovey Taiget Persistent Targets Bound Voumes Tevices Select ataeet and cick Sha W ttar the storage dear hor Ihat GE ee oimation about Ihe session eonneclone and deica fot that Gear Gobo Wb che Abbildung H 15 Abbildung H 15 Status ist Connected die Einstellung fur den Initiator wurde vorge nommen Schritt C Initialisieren formatieren mounten Sie die Disk 1 Gehen Sie zu Start gt Systemsteuerung gt Computerverwaltung gt Ger te manager gt Disk Drives oc br ber Manageme rit 5e ee yew window ep De GG a wi Corpte er Local ER EK System Took S d Evert Yig ag HOST2E000PL A380 Sharad Folders y Local Users and Groups a an FLADT SCS Disk Device Performance Logs and Aket S an PA Multi Path Disk Denice Derice Manager H E Depar adapers Abbildung H 16 Abbildung H 16 Disk Drive Status des GEVIRAID Controllers 2 Gehen Sie zu Sta
40. OK 5 Done The VG has been deleted Tips The action of deleting one VG will succeed only when all of the related UDV s are deleted in this VG Otherwise it will have an error when deleting this VG Step 9 Free global spare disk 55 To free global spare disks please follow the procedures 1 Select Volume config Physical disk 2 Select the global spare disk by clicking the checkbox of the row then click Free disks to free disk Step 10 Done all volumes have been deleted e Example 2 Example 2 is to create two UDVs in one VG One UDV shares global cache volume the other uses dedicated cache volume First dedicated cache volume should be created it can be used in creating UDV The last delete them Each UDV is associated with one specific CV cache volume to execute the data transaction Each CV could have different cache memory size If there is no special request in UDVs it uses global cache volume Or user can create a dedicated cache for indivifual UDV manually Using dedicated cache volume the performance would not be affected by the other UDV s data access The total cache size depends on the RAM size and set all to global cache automatically To create a dedicated cache volume first step is to cut down global cache size for the dedicated cache volume Please follow the procedures Step 1 Create dedicated cache volume Create e Delete e No Size UDY name 1 40 e e Glob
41. OOOOd EE Ey E CLEE AE Eee EE EEN el Ee ea a i EN E EN EEA E le 1 Zentrale Verriegelung 2 LCD Statusanzeige 3 Bedientasten 4 LED f r Host Zugriff 5 Power LED 6 LCM Module Hotplug 2 1 3 R ckseite 1 2 38 4 1 4 x L ftermodul Hot Plug im Betrieb tauschbar Ein Aus Schalter Serielle Schnittstelle RS 232 Com1 Sub D redundante Netzteile Sicherheitsalarm Relais Securion Interface Web GUI Port Ethernet 10 100 1000 Base T RJ45 ISCSI Host Ports Ethernet 10 100 1000 Base T RJ45 SAS Schnittstelle JBOD Erweiterung ON OO OD P WP A 10 2 2 iSCSI Einf hrung ISCSI Internet SCSI ist ein Protokoll das SCSI Small Computer System Interface Befehle und Daten in TCP IP Pakete einbettet mit dem Zweck Speichermedien mit Servern ber die herk mmlichen IP Infrastrukturen zu verbinden ISCSI stellt Hoch Performance SANs ber Standard IP Netzwerke wie LAN WAN oder das Internet zur Verf gung IP SANs sind echte SANs Storage Area Networks die es erlauben wenige Server an eine unendliche Anzahl von Storage Volumes durch die Nutzung von iSCSI ber TCP IP Netzwerke zuzuordnen IP SANs k nnen die Speicherkapazit t mit jedem Typ und Modell von Speichersystemen skalieren Zus tzlich verwendet es beliebige Netz werke Ethernet Fast Ethernet Gigabit Ethernet und kombiniert Betriebssysteme Microsoft Windows Linux Solaris etc innerhalb des SAN Netzwerkes IP SANs se hen
42. RAID System User Manual Preface About this manual This manual is the introduction of GeViRAID CableP100 BackplaneP120C controller and to help user to know the operation of the disk array system easily Information contained in the manual has been reviewed for accuracy but not for product warranty because of the various environments OS settings Information and specification will be changed without further notice For any update information please visit www geutebrueck com and your contact windows Copyright 2008 GEUTEBR CK GmbH All rights reserved Thank you for using GEUTEBR CK Technology products if you have any question please e mail to www geutebrueck com We will answer your question as soon as possible Package content One P series controllers e Backplane solution o P120C N Gigabit LAN x2 to SATA II xN bays RAID controller e Cable solution o P100C N Gigabit LAN x2 to SATA II xN bays RAID controller Console cable Available only in the package of the cable solution Please contact with www geutebrueck com to get the latest user manual and firmware The RAM size of P100C P120C is recommended DDR 333 512MB or above Please refer to the certification list in Appendix A Model comparison P100C PA20C Minimum DDR 333 DDR 333 RAM 512MB 512MB cable Cable Backplane Backplane p ports Single node Trunking S LACP 1500 9000 1500 3900 1500 9000 No Snapshot Q
43. RAIDS D e fie NG RO 100 Attach Gi Snapstot kel _reabe 5 Detete Abbildung 4 2 3 Abbildung 4 2 3 Migration eines RAID 0 in ein RAID 5 ist gerade bei 12 Fur eine Migration Erweiterung muss die Gesamtgr e der VG gr er oder gleich der ursprunglichen VG sein Eine Erweiterung desselben RAID Levels mit denselben Disks der urspr nglichen VG ist nicht erlaubt Wenn der Benutzer bei der Einrichtung der Migration diese nicht korrekt vornimmt zeigt der Controller Popups mit Warnhinweisen an Im Folgenden finden Sie Details der Nachrichten 1 Invalid VG ID Die Quell VG ist ung ltig 2 Degrade VG not allowed Die Quell VG ist degradiert 3 Initializing rebuilding operation s going Die Quell VG wird initialisiert oder befindet sich im Rebuild 4 Migration operation s going Die Quell VG wird bereits migriert 5 Invalid VG raidcell parameter Ung ltige Konfiguration Z B Kapazit t der neuen VGs lt Kapazit t der alten VGs Stripe Size der neuen VGs lt Stripe Si ze der alten VGs Oder Konfiguration der neuen VGs Konfiguration der al ten VGs 6 Invalid PD capacity Mindest PD Kapazit t der neuen VGs lt Mindest PD Kapazit t der alten VGs Achtung W hrend des Neuaufbaus oder der UDV Erweiterung kann die VG Migration nicht durchgef hrt werden 4 3 UDV Erweiterung Um ein UDV zu vergr ssern f hren Sie die folgenden Schritte druch 1 Wahlen Sie Volume Config User Data Volume 2 Entscheiden
44. Sie welche UDV erweitert werden soll klicken Sie in der Spalte Size neben der Nummer auf den Schalter Le 3 ndern Sie die Gr e Die Gr e muss gr er als die urspr ngliche Gr e sein Klicken Sie dann auf SOIT at starten 4 Wenn die Erweiterung gestartet wurde sehen Sie ein I in Status 3 und den Fortschritt in Prozent in der Spalte R um die Erweiterung zu 62 Volume config User data volume Extend Size i 10 Free 7 1 GB cc Back o Dpfgm w Abbildung 4 3 1 d Volume config User data volume Attach m Shap Sor Ei Create Delete d Size ei a R Snapshot VG CV CI No Name ee Status 1 2 3 RAID eu Ge me Sich 1 UDV RO 10 i 0 00 0 00 EI o e Far ne e D 58 RAIDS 0 e A VERO 100 Attach a Snhapsnat Kl Create LG Delete D Abbildung 4 3 2 Abbildung 4 3 2 Erweiterung der UDV RO von 5 GB auf 10 GB Achtung Eine Vergr erung des UDV w hrend eines Rebuild oder einer Migra tion ist nicht m glich Tips Die UDV Erweiterung muss gr er als das Original sein 63 4 4 Snapshot QSnap Rollback GEVIRAID II Snapshot on the box halt den Stand von Daten auf dem ZielVolume im logischen Sin fest Die zugrunde liegende Technik ist Copy on Write Wann immer eine Anderung ab dem Zeitpunkt des Snapshots geschrieben werden soll erfolgt das auf einen anderen Bereich Dieser Bereich bezeichnet als Snap UDV ist eigent lich ein neues UDV dem eine LUN und diese wieder e
45. Sie den Alarm Damit sind Ihre Einstellungen erfolgreich durchgef hrt 86 Konfiguration von SNMP Simple Network Management Protocol Anzeigen einer GeViRAID Il Fehlermeldung Uber SNMP Netzwerk Beispielkonfiguration GeViRAID Il gt GeViScope Ereignismeldung Verfahren Sie bitte wie in den Screenshots abgebildet 192 168 201 10 192 168 201 150 SCSI GeviScope GeVIRAID II 1 1 1 GeViRAID Konfiguration Konfigurieren Sie im Men System config des GeViRAID II die IP Adresse Geben Sie im Untermen IP Adress folgende IP Adresse ein GeViRAID IP Adress 192 168 201 150 GeVviRAID System config IP address ec Guick Install System config System config F System rare D D DHCP IP address Static Address 192 168 201 150 Mask 56 255 2755 0 Gateway 192 168 201 254 PAS 127 0 D 8 Konfiguration SNMP Wahlen Sie mit einem Mausklick das Unterment SNMP um die SNMP Benachrich tigungsfunktion SNMP trap f r die Alarmmeldung Uber SNMP einzustellen Es k nnen 3 Empf nger SNMP trap addresses adressiert werden Die Default community Einstellung ist public F r den Remote PC GeviScope ist in diesem Beispiel die SNMP trap address 1 gew hlt Geben Sie die IP Adresse und den UDP Port 162 ein 192 168 201 10 162 GEUTEBRUCK GeviRAID System config SNMP ef Quick install d System config Syste m config 5 e System name SNMP trap
46. Volume Config Cache Volume dizierte Cache Volume mit 20MB 49 Create a Delete en UDV name Global UDV R5 2 Create a Delete en nutzt das UDV UDV R5 2 das de Schritt 4 Weisen Sie dem UDV eine LUN zu Siehe Schritt 3 in Beispiel 1 Schritt 5 Erstellen Sie eine dedizierte Spare Disk Um dedizierte spare disks zu erstellen verfahren Sie wie folgt 1 Gehen Sie zu Volume Config Physical Disk 2 Wahlen Sie aus der Auswahlliste eine VG aus dann wahlen Sie die freie n Disk s Klicken Sie nun auf Pediested spares um f r die gew hlte VG eine dedizierte Spare Disk festzulegen 3 der Spalte Status 1 sehen Sie f r diese Festplatte nun das DS Icon Select Free disks Global spares Dedicated spares Slot WWN a a Status 1 2 Speed l 1 C e 2007001378340040 38 VG RS Se D pp 1 566 _ d en 3 Good l 2017001378320209 KI VG RS Hp 1 565 3 Th OE C e 2D1B001379320249 38 VG RS Zn d D ep 1 565 A n et sy i Good e E 8 2D130013782202493 3E Yo RS mmer FR pop 1 566 a En Zeen Ke TS Good em C 8 201a001378320249 36 VO RS Dos 1 566 6 Good C e gt 0c4001378000108 36 a H FR 1 5Gb 7 Lu Food a e 201c0013783202d3 36 onus fi Fr 1 5Gb E e 201b0013783202d9 36 anaes F Fn 1 556 Abbildung 3 6 7 13 Abbildung 3 6 7 13 Slot 5 wurde als dedizierte Spare Disk f r die VG VG R5 eingerichtet Schritt 6 Die Laufwerke k nnen nun als SCSI Festplatten genutzt werden L schen von UDV und VG Schritt
47. Warning EGE error _ Warning Single bit ECC error is detected Error Multi bit ECC error is detected Enor ECC DIMM Info ECC Memory is installed Installed Error Host hip Error Host channel chip failed Error Drive chip failure Error Drive channel chip failed Warning Ethernet port failure Warning GUI Ethernet port failed e HDD IO events e ee Ee Warning Diskeror Error Disk lt slot gt read block error Warning Diskerror Error Disk lt slot gt writes block error m Warning HDD failure Error Disk lt slot gt is failed Warning Channelerror Error Disk lt slot gt IO incomplete m e SES events i i wee en e O en Failure device i IS disabled e Environmental events ee eS ee Ee eee lt Web UI or Console UI gt Info Admin logout from lt IP or serial console gt via lt Web UI or Console UI gt 87 Info iSCSI login from lt IQN gt lt IP Port login Number gt succeeds iSCSI data port Warning iSCSI login from lt IQN gt lt IP Port login reject Number gt was rejected reason of initiator error authentication failure authorization failure target not found unsupported version too many connections missing parameter session does not exist target error out of resources 11 unknown r ro D sees the auto shutdown immediately Pee eee re Seer vere Tae higher ro as ee do the auto shutdown immediately TE ngherowers o SaM higher
48. auch Security Mechanismen Datenreplikation Multi Path und hohe Verf gbarkeit vor Speicherprotokolle wie z B iSCSI haben zwei Enden in ihrer Verbindung Diese Enden nennt man Initiator und Target In einem iSCSI werden sie iSCSI Initiator und ISCSI Target genannt Der iSCSI Initiator erfordert oder initiiert jede iSCSI Kommunikation Er fragt alle SCSI Operationen wie schreiben oder lesen an Ein Initiator ist normalerweise auf der Host Server Seite aufgebaut entweder ein iSCSI HBA oder ein iSCSI SW Initiator Das iSCSI Target ist das Speicherger t selbst oder ein Device welches Volumes oder virtuelle Volumes steuert und bedient Das Target ist das Device welches SCSI Befeh le ausf hrt oder Bridges zu einer verbundenen Storage Einheit herstellt ISCSI Tar gets k nnen Disks Kassetten RAID arrays tape libraries usw sein iSCSI device 1 target gt iSCSI device 2 target Die Host Seite braucht einen iSCSI Initiator Der Initiator ist ein Treiber welcher den SCSI Traffic ber iSCSI regelt Der Initiator kann entweder eine Software oder Hard ware HBA sein Siehe dazu die Zertifizierungsliste fur iSCSI HBA s im Anhang A 11 Initiatoren in einem Betriebssystem oder andere softwareseitige Initiatoren nutzen den Standard TCP IP Stack und Ethernet Hardware w hrend iSCSI HBA s die eigenen ISCSI und TCP IP Stacks nutzen Hardware iSCSI HBA s stellen ihr eigenes Initiatoren Tool zur
49. both VG and UDV will be kept but LUN configuration will be cleared to avoid conflict with system 2 4 7 Support Microsoft MPIO and MC S MPIO Multi Path Input Output and MC S Multiple Connections per Session both use multiple physical paths to create logical paths between the server and the storage device In the case which one or more of these components fails 81 causing the path to fail multi path logic uses an alternate path for I O so that applications can still access their data Microsoft ISCSI initiator supports multi path function Please follow the procedures to use MPIO feature 1 2 3 4 et 6 l A host with dual LAN ports connects cables to GeViRAID series controller Create a VG UDV attach this UDV to the host When installing Microsoft iSCSI initiator please install MPIO driver at the same time Logon to target separately on each port When logon to target check Enable multi path Please refer to Appendix D step 6 MPIO mode can be selected on Targets gt Details gt Devices gt Advanced Rescan disk There will be one disk running MPIO For detailed setup steps please refer to Appendix F MPIO and MC S setup instructions MC S setup steps are very similar to MPIO please also refer to Appendix F 82 Appendix A Certification list e RAM P100C P120C RAM Spec 184pins DDR333 PC2700 Reg register or UB Unbufferred ECC or Non ECC from 64MB to
50. can support ATAPI IDENTIFY PACKET DEVICE command and the speed can achieve Serial ATA Gen 1 signaling speed 1 5Gbps Unknown gt The disk doesnt support above command so the speed is defined as unknown Speed 43 e PD operations description Make the selected hard drive to be free for use Global set the selected hard drive s to global spare of all spares VGs Dedicated Set hard drive s to dedicated spare of selected VGs spares In this page GeViRAID controller also provides HDD auto spindown down function to save power The default value is disabled User can set up in physical disk page too Auto spindown is supported on P100C P120C P150C P200C does not have this feature Auto spindown Disabled Select 5 Free disks e Global spares e Dedicated spares Figure 3 6 2 2 d Volume config Physical disk Auto spindown Auto spindown Figure 3 6 2 3 3 6 3 Volume group Enter Volume group to view the status of each volume group e VG column description 44 Create kW Delete e Total Free No Name GB GB SD UDY Status 11213 RAID 1 VG RO e s i 297 267 4 1 Dale Gen VGo Rp Online RAID 6 a 8 m 148 128 4 1 nn em Create e Delete e Figure 3 6 3 1 Figure 3 6 3 1 There is a RAID 0 with 4 physical disks named VG RO total size is 297GB free size is 267GB related to 1 UDV Another is a RAID 6 with 4 physical disks named VG R6 Number of volume
51. ck cken o TT garan RADA 1 w WORE 663 attach e mapshot Create e Abbildung 3 6 4 1 Abbildung 3 6 4 1 Erstellen Sie ein UDV mit der Bezeichnung UDV 01 greift auf VG RO zu Gr e ist 30 GB Status ist online Write Back High Priority zugewiesen zu 1 LUN mit einem Cache Volumen von 663 MB 10 GB Platz f r Snapshots QSnap Das andere UDV wurde als UDV 02 bezeichnet es wird gerade initialisiert und ist bei 46 e UDV column description Nummer dieses User Data Volume Mit dem Schalter unterhalb der UDV Nummer k nnen Sie sich unter More Information n here Informationen anzeigen lassen Dort werden Details der User Vo lume Group angezeigt Name dieses User Data Volume Der Schalter unter dem UDV Namen f hrt zur Funktion Rename Size GB Gesamte Kapazit t dieses User Data Volume Der Schalter unter halb der Gr e f hrt zur Extend Funktion Der Status dieses User Data Volume Online gt das User Data Volume ist online Fail gt bei diesem User Data Volume ist ein Fehler aufgetreten WT gt Write Through WB gt Write Back RO gt Read Only Der Schalter unterhalb des Status 1 f hrt zur Funktion Set read write mode Status2 HI gt High priority 39 P gt User Data Volume wird gerade initialisiert R gt User Data Volume befindet sich im Rebuild M gt User Data Volume wird migriert P g
52. config System name System name P200C 300001 3 4 2 IP Addresse W hlen Sie IP Address um die IP Adresse f r Remote Administration Usage zu n dern Sie haben 2 M glichkeiten DHCP IP Adresse vom DHCP Server erhalten oder eine statische IP Standardm ig ist DHCP aktiviert Benutzer k nnen die HTTP HTTPS und SSH Portnummer ndern wenn die Standard Portnummer vom Host Server nicht akzeptiert wird 22 System config IP address DHCP Static Address Mask Gateway DNS MAC 00 13 75 00 00 DB HTTP port 80 HTTPS port 443 SSH port 99 Abbildung 3 4 2 1 3 4 3 Language In der Auswahl Language k nnen Sie die Sprache der Web UI festlegen Die Option Auto Detect wird von den Spracheinstellungen des Browsers erkannt System config Language Language Auto Detect Auto Detect English Simplified Chinese Abbildung 3 4 3 1 3 4 4 Login Konfiguration In der Auswahl Login Config k nnen Sie einen einzigen Administrator festlegen und den Zeitpunkt f r das automatische Ausloggen einstellen Dieser einzige Administrator kann verhindern dass mehrere Benutzer gleichzeitig auf denselben Controller zugrei fen 1 Auto logout Es stehen folgende Optionen zur Verf gung 1 Disable 2 5 mins 3 30 mins 4 1 hour Das System wird sich automa tisch abmelden wenn der Benutzer innerhalb einer bestimmten Zeitdauer nicht reagiert 2 Login lock D
53. den er beim Host Server iscsi Initiator sieht z B iqn 2004 08 tw com qsan p720c 000a0001f Standardziel Wahrend des QCopy Vorgangs verhalt sich das Quellensystem wie ein Host Server der seine Daten zum Zielsystem kopiert Beim Quellensystem handelt es sich nicht um ein disk device in QCopy also ist der Node Name anders um QCopy vom disk device zu unterscheiden 4 6 Disk roaming Physical Disks k nnen im gleichen System neu angeordnet werden oder komplett von einem GEVIRAID Il in ein anderes gebracht werden Diesen Vorgang nennt man Disk Roaming Folgende Punkte sind dabei zu beachten 1 Die Firmware der beiden GEVIRAID II Systeme muss auf dem gleichen Stand sein Dabei ist immer der neuere Stand zu empfehlen 2 Alle Physical Disks eines VG sollten zusammen von einem GEVIRAID II zum anderen gebracht werden Die VG und UDV Konfiguration beider wird beibehal ten Die LUN Konfiguration der Disks aus System eins wird jedoch gel scht um Konflikte in System 2 zu vermeiden 70 4 7 Support Microsoft MPIO and MC S MPIO Multi Path Input Output und MC S Multiple Connections per Session verwenden beide mehrere physikalische Pfade um logische Pfade zwischen dem Server und dem Speichermedium herzustellen Falls eine oder mehrere dieser Komponenten nicht funk tionieren und so auch der Pfad nicht funktioniert benutzt die Multi Path Logik einen ande ren Pfad f r I O so dass die Anwendungen trotzdem noch auf ihre D
54. dismounten Dieser Dismount Schritt vermeidet jegliche Dateninkon sistenz von anderen Nach dem Dismount des UDV vom Host Server klicken Sie YES als Best tigung Wenn QCopy Daten verarbeitet werden erscheint bei Volume Config User Da ta Volume in der Statusspalte f r QCopy und den fertiggestellten Prozentsatz die Anzeige 7 P Das Quellensystem erstellt eine INFO die die Einstellung der Kopie beschreibt Wurde die Replikation erfolgreich erstellt so erzeugt das Quellensystem eine INFO die beschreibt wann die Erstellung der Replikation begonnen und be endet wurde Das Quellensystem versucht im Falle eines Netzwerkfehlers oder unsicherer bertragung eine neue Verbindung mit dem Zielsystem aufzubauen Falls eine Replikation wegen einer Unterbrechung angehalten wurde erstellt das Quel lensystem eine Nachricht WARNING die die M glichkeit einer Unterbre chung aufzeigt um den Kopiervorgang anzuhalten Bei der M glichkeit die Replikation anzuhalten kann es sich um network link failure the target sys tem not reachable connection fail etc handeln Nach Beseitigung der Ursachen f r die Unterbrechung kann der Benutzer ma nuell die Qcopy Replikation wieder aktivieren um diese wieder in Gang zu set zen Das Quellensystem erstellt eine INFO die dem Benutzer mitteilt dass mit dem Kopieren fortgefahren wird arm Nach Beendigung der QCopy kann der Benutzer die LUN des Ziel UDV l schen um einen f
55. e 2017001378320 dJ9 38 VG R5 fi op 1 566 3 Good E e 20189001378ar02d9 38 VG R5 a fi op 1 566 Good e 20190013783202d9 38 VG Ri em Fi RD 1 566 J Good E o 0130013783 7074J9 38 VOR D ps 1 566 D Good BR e Oc40013 8000108 EIS eem fi FR 1 566 H Good u 01cO01378ar02d9 EIS fi FR 1 566 a g E 20160013783 02d9 38 zum A FR 1 55b 3 Figure 3 6 7 13 Figure 3 6 7 13 Slot 5 has been set as dedicated spare disk of VG named VG R95 Step 6 Done The PDs can be used as iSCSI disks Delete UDVs VG please follow the steps Step 7 Detach LUN from UDV Please refer to Step 6 of Example 1 to detach LUN Step 8 Delete UDV User Data Volume Please refer to Step 7 of Example 1 to delete UDV Step 9 Delete VG User Data Volume Please refer to Step 8 of Example 1 to delete VG Step 10 Free dedicated spare disk To free dedicated spare disks please follow the procedures 1 Select Volume config Physical disk 2 Select the dedicated spare disk by clicking the checkbox of the row then click Free disks 7 to free disk 50 Step 11 Delete dedicated cache volume To delete the cache volume please follow the procedures Select Volume config Cache volume select a CV by clicking the checkbox of the row Click m Delete S Choose OK Done The CV has been deleted There will pop up a confirmation page ie IN Caution Global cache volume cannot be deleted
56. eingeschaltet ist 17 Kapitel 3 Bedienung der Web GUI GUI Struktur Men baum In der folgenden Tabelle ist die Struktur der Benutzeroberfl che dargestellt CCG ns gt Step 1 1 Step 2 Step 3 Confirm System Config System Name gt System Name IP address gt gt DHCP Static Address Mask Gateway DNS HTTP Port HTTPS Port SSH Port Language gt Sprache Login config gt Automatisches Logout Loginsperre Password gt Altes Passwort Passwort Best tigen Date gt Time zone Date Time NTP Server Mail gt Absenderadresse Empf ngeradresse Gesendete Ereignis se SMTP Relay SMTP Server Autentifizierung Konto Passwort Best tigen Testmail senden SNMP gt SNMP Trap Adresse Community Ereignisse senden Messenger gt Messenger IP Hostname Ereignisse senden System log gt Server IP Hostname Port Facility Ereignislevel server Event log gt Filter Herunterladen Stummschalten L schen ISCSI config Entity Property gt Entity Name iSNS IP NIC gt Aggregation IP settings f r iSCSI ports wird Default Gateway Set MTU Node gt Authentifizierung ndern Session gt L schen CHAP account gt Erstellen L schen Volume config Physical disk gt Free Disks Global Spare Disks Dedizierte Spares Weitere Informationen Auto Spindown Volume group gt Erstellen L schen Weitere Informationen Umbenennen Migrieren User data gt Verbinden Snapshot Erstell
57. group The button next to the No is More Information indication It shows the details of the volume group Volume group name The button next to the Name is Rename function Total GB Total capacity of this volume group Free GB Free capacity of this volume group eo The number of physical disks of the volume group UDV The number of user data volumes related to the volume group DG gt DeGraded mode This volume group is not completed The reason could be lack of one disk or failure of disk Status2 R gt Rebuild This volume group is doing rebuilding Status 3 M gt Migration This volume group is doing migration The status of volume group Online gt volume group is online Fail gt volume group is fail 45 The RAID level of the volume group The button next to the RAID level is Migrate function Click Migrate can add disk s to do expansion or change the RAID level of the Volume group e VG operations description Create a volume group Delete a volume group 3 6 4 User data volume Enter User data volume function to view the status of each user data volume Attach e Snapshot e Create e Delete e Size R Snapshot G CH m No Name GB Status 1 2 3 E RAID LUN GB name ME 1 UDYW O1 30 Gwe OHI 9 99 10 0 Online a C e z gt men e d RAIDO 1 a VORO 662 2 UDW 02 20 i Ows Gui 10 00 10 00 u gt Luc ii _ 1 46 RAIDS 1
58. hard drive crash when it is writing data or rebuilding a failed hard drive Enter S M A R T function will display S M A R T information of hard drives The number is the current value the number in parenthesis is the threshold value The threshold values of hard drive vendors are different please refer to vendors specification for details S M A R T information is only supported on SATA drive SAS drive does not have It will show N A in this web page Enclosure management 5 M A R T Reallocated sector Seek error Spin up Calibration Temperature Read error Spin up Slot rate time count rate retries rebries Status 1 203 63 253 63 253 0 253 157 253 223 41 a SE Good z 100 16 107 24 100 5 10067 10060 31 En en Good 3 100 16 104 24 100 5 10067 10060 32 m Ge Se Good d 70 6 96 0 100 36 75 30 10097 a1 emm z Good 5 100 16 102 24 100 5 100 57 100 60 32 e e Good 6 203 63 253 63 2530 253 157 253 223 28 Good Fj 94 16 99 24 100 5 100 67 100 60 31 Se 5 Good E 200 51 171 21 200140 200 51 100151 100 51 30 m Figure 3 7 3 1 Enter UPS function will set UPS Uninterruptible Power Supply 63 UPS Type None el Shutdown Battery Level oni 5 ha Shutdown Delay fs 0 H Shutdown UPS CFF sl Status Battery Level n Confirm e Figure 3 7 4 1 Currently the system only support and communicate with smart UPS function of APC
59. hil 3 Geben Sie einen UDV Namen ein w hlen Sie einen VG Namen und weisen Sie dem UDV eine Gr e zu berpr fen Sie ob die Einstellungen stripe high block size read write mode and set priority Ihren Anforderungen entsprechen und klicken Sie zum Abschluss auf ET 4 Fertig Ein UDV wurde erstellt 5 F hren Sie den Vorgang erneut aus um ein weiteres UDV zu erstellen Attach ory i hal gt Create D Deala a Size R Snapshot YG CN a Wo Name ce Status 1 2 a de RAID LUM fee aed UEA 1 WO R 1 50 wa D Hi 0 00 0 50 E m gt on fi Be RAIDS O s Was 120 g LUDN R R D D wn Du 0 00 0 00 ie o JAR i Gm RAIDS O 8 M n 120 Altach a Gapgiwit Gre ate B Liege a Abbildung 3 6 7 4 Abbildung 3 6 7 4 Erstellung von UDVs benannt UDV R5 1 und UDV R5 2 bezogen auf VG R5 die Gr e von UDV R5 1 betr gt 50 GB die Gr e von UDV R5 2 betr gt 64 GB Der Status dieser UDVs ist online write back high priority mit einem Cache Volume von 120 MB Die Initialisierung von UDV R5 1 liegt bei ungef hr 4 Es ist kein LUN zugewiesen Schritt 3 Verbinden einer LUN mit dem UDV Daf r gibt es zwei Methoden 1 Dr cken Sie unter Volume Config User Data Volume auf D Attach So 2 Drucken Sie unter Volume Config Logical Unit auf 7 Attach Die Abl ufe sind wie folgt 44 UDY JDV R5 1 SOGB sl Host LUN 0 JS Permission Read only Read write lt lt Bac
60. iSCSI Initiator Properties Figure F 8 Input the IP address of iSCSI data port 1 192 168 11 229 as mentioned in previous page Add Target Portal 192 169 11 229 Figure F 9 111 9 Add second Target Portals on Microsoft iSCSI initiator 2 03 iSCSI Initiator Properties 13216811229 3260 Default perak Figure F 10 10 Input the IP address of iSCSI data port 2 192 168 12 229 as mentioned in previous page 112 Add Target Portal 192 168 12 229 enact Figure F11 11 The initiator setting is done iSCSI Initiator Properties HR ult 132 168 12 223 3260 Default Default Default Fl LTS a Apply Figure F 12 113 12 Log on iSCSI Initiator Properties Figure F 13 13 Enable Enable multi path checkbox Then click Advanced Log On to Target 114 Figure F 14 14 Select Target Portal to iSCSI data port 1 192 168 111 229 Then click OK Advanced Settings ding authentication Deimeen atarget and ani inittator try na am Ti Spent the game target linet secret tral wes Goler on tie target for tare mitrata Username Large E Perom mutual authentication louse mutual CHAR specii an initiator secret on the Initiator settings Page DG Fe IL EIERE GE Le E EE IL OI Figure F 1 5 15 Log on Enable multi path again 115 iSCSI Initiator Properties Figure F 16 16 Enable
61. kein Speicherplatz f r ein Snapshot QSnap verf gbar Wenn die Funktion Snapshot QSnap ben tigt wird erstellen Sie bitte die Volumes manuell Weitere Einzelheiten finden Sie im Abschnitt 4 4 Die Funktion Quick Install von GEVIRAID verf gt ber ein ausgekl gelteres System Wenn das System vollst ndig mit 8 HDD oder 16 HDD besetzt ist und alle HDDs die selbe Gr e haben listet die Funktion GEVIRAID Quick Install alle M glichkeiten und Gr en auf den verschiedenen RAID Levels auf GEVIRAID Quick Install verwendet dann f r den vom Benutzer ausgew hlten RAID Level alle verf gbaren HDDs Wenn das System jedoch mit verschieden gro en HDD besetzt ist z B 8 200 G HDD und 8 80 G listet der GEVIRAID Controller auch alle M glichkeiten und Kombinationen ver schiedener RAID Level und verschiedener Gr en auf Nachdem der Benutzer das RAID Level ausgew hlt hat stellt er m glicherweise fest dass immer noch nicht alle HDD verwendet werden Status Free Aufgrund des fortschrittlicheren Systems von GEVIRAID in Bezug auf die Funktion Quick Install kann der Benutzer Folgendes nut zen 1 Die gr tm gliche Kapazit t der RAID Level aus denen der Benutzer w hlen kann und 2 Die geringste Anzahl an Disks f r den RAID Level die Volume Gr e 20 Der Benutzer w hlt beispielsweise RAID 5 und der Controller verf gt ber 12 200 G HDD 4 80 HDD Wenn dann alle 16 HDD f r ein RAID 5 verwendet werden betr gt die maximale Gr
62. message of Warning power lost during migration may cause damage of data to give user warning When the power is abnormally off during migration the data is in high risk Migration starts and it can be seen from the status 3 of a VG with a running square and an M In Volume config User data volume it displays an M in Status 4 and complete percentage of migration in R Y 71 Name Vu RU RAID Level RAIDS sl RAID PD slot es ao Select PD lt lt Back e Next gt gt e Figure 4 2 1 Volume config Volume group Create D Delete e No Name Total Free PD UDV Status 12 3 RAID GB GB cudnt o i VG RO eech RAID 5 e e 76 71 3 1 EES on Create e Delete a Figure 4 2 2 Figure 4 2 2 A RAID 0 with 2 physical disks migrates to RAID 5 with 3 physical disks Volume config User data volume Attach a Snapshot Create a Delete a Size R a Snapshot VG CV LJ No Name CB Status 1 A 3 g RAID et UN GB name MB 1 UDW RO 5 FR Aw BHI 0 00 0 00 Online i C zu S P Om 12 RAIDS LU e VGO RO 100 Attach e Snapshot e Create e Delete e Figure 4 2 3 Figure 4 2 3 A RAID 0 migrates to RAID 5 complete percentage is 12 To do migration expansion the total size of VG must be larger or equal to the original VG It does not allow expanding the same RAID level with the same hard disks of original VG During setting migration if user doesn t setup corr
63. nicht auf Windows XP oder Windows 2000 Pro fessional L sung F r MPIO Windows Server 2003 oder Windows 2000 Server ver wenden 80 D Security Alarm Relais Anschluss Security AlarmRelais gt Hardware Anschluss Verbinden Sie den Anschluss f r das Security Alarm Relais mit dem Schalteingang ihres GeViScope MultiScope GeVisContact LAN Anschl sse an den Steuereing ngen Ereigniskontakte Das GeViScope Ger t verf gt ber 16 Steuereing nge jeweils mit kOhm pull up Widerstand an 5 V Die Steuereing nge sind verteilt auf die beiden 25 poligen Sub D Buchsen Input 1 8 und Input 9 16 An diese Eing nge k nnen Sie potentialfreie Kon lt gt lt gt takte f r eine Ereignisaufzeichnung anschlie en NE A Die Ereigniskontakte k nnen beim ffnen Schlie en nn O eer oder im Sabotagefall die Bildaufzeichnung starten und stoppen quittieren Ein solches Kontaktereignis kann auch Ausgangsrelais schalten Die Funktion jedes Eingangskontakts wird per Men in der Einstell Oberfl che GSCSetup festgelegt Abbildung 25 poligen Sub D Buchsen Input 1 8 und Input 9 16 81 Belegung der 25 poligen Sub D Buchse n lotseitig z J Emm gt me 25 Ruhekontakt 12 Umschaltkontakt 24 __ lArbeitskontkt Relais3 Relais 7 23 ___l Umschaltkontakt a ren eg 22 _ Ruhekontkt 9 Umschaltkontakt 21
64. o K Indexing Service nn Properties Local Computer General Log On Recover Dependencies Service name Messenger Display name Transmits net send and Alerter service messages A peter clients and servers This service is not Description ae Path ta executable C AWINDOWS aystemae evohost exe k netsves u EA Startup type Automatic Service status Stopped MtrapRecever ER Trap Source Port 162 Total Traps Received 0 Sender Message Time ii Eat 89 Mibs Laden Sie die MIB Datei qsan mib aus dem Verzeichnis C Tools GeViRAID USAN SMMP MIB doe Exploders F gen Sie den Ziel Host 192 168 201 150 GeViRAID und den Ziel Port 162 hinzu 192 168 201 150 90 Actions F gen Sie die Ziel IP Adresse 192 168 201 150 GeVIRAID ein und w hlen Sie Sender IP Execute Configure Trap Receiver CTT Exploders Trap Data Ms zen gt Logging Miscellaneous Watch Value Sender IP 192 168 201 150 Trap Receiver Action Add Watch Achons l Sender IF Explode Add Modify Delete e Execut SE Email 192 168 201 150 Diseard Add Executable B Cancel C Tools GeviRalDMailure bat 3 Program Trap A t rn Include Trap Data Cancel Wahlen Sie C Tools failure bat f r Die net send Funktion Mame
65. read write error length lt gt lt read write gt unrecoverable start fail succeed bitmap lt BITMAP gt lt started failed finished gt Snapshot QSnap events re Deepen ern Tase tege sagt Warning Fail to allocate snapshot Lee Fal io ee SEA QSnap Mem memory for UDV lt name gt Failed Allocate Snapshot Warning Fail to allocate snapshot QSnap QSnap Space space for UDV lt name gt Failed on age Ee QSnap Threshold QSnap of UDV lt name gt has been reached Delete has been deleted Info Snapshot QSnap Info The oldest snapshot QSnap version of me o UDV lt name gt has been replaced by the new one QSnap Set Size for Info Set the snapshot QSnap size of UDV 90 Snapshot QSnap lt name gt to lt number gt GB Info Snapshot QSnap Info The snapshot QSnap of UDV lt name gt rollback start rollback start Info Snapshot QSnap Info The snapshot QSnap of UDV lt name gt rollback finish rollback finish e QCopy events E EE Info QCopy Starts Info QCopy start Target lt node name gt IP x X X X Type Duplicate Info QCopy Restarts Info QCopy restart Target lt node name gt IP X X X X Type Duplicate QCopy Connection Warning QCopy connection fail Down es QCopy Connection Warning QCopy task was aborted Retry QCopy Task Warning QCopy task was aborted Setting reason UDV LBA block size ONLY support 512 bytes C Kn
66. replication setting If the replication has been completed successfully the source system will issue one INFO event describes the replication started at what time and completed at what time The source system will try to recoonect the target system when there is any network error or unstable transferring And if the replication has been stopped for some interrupts the source system will issue one WARNING event describes the possibility of the interrupts to stop the replication The possibility to stop the replication may be network link failure the target system not reachable connection fail and etc When the causes to the interrupts have been removed the users can manually activate the QCopy replication again to restart the replication work The source system will issue one INFO event describes the replication has been resumed When the QCopy is completed user can delete the LUN of the target UDV for avoiding wrong operation or deleting data When recovery is needed the operation steps are the same as replication steps user only needs to setup the QCopy service from target system reversely QCopy is only supported by P120C only 20 UOVO4 1624 e Online 03 28 16 24 44 D maen Den BHI RAID 6 o Pr VG6G 116 OCopy Node Name _ com gsan p120c 000320358e refinittator 001 Attach e Snapshot oe Create e Delete D Figure 4 5 1 Figure 4 5 1 setup QCopy on selected snapshot QSnap
67. sind die Schritte genau dieselben wie f r MPIO Bitte sehen Sie sich die Abbildungen F 1 bis F 9 an 1 Erstellen Sie eine VG mit RAID 5 mithilfe von 3 HDDs 117 2 Erstellen Sie ein UDV mithilfe einer RAID 5 VG 3 Starten Sie den Microsoft iSCSI Initiator 2 03 und berpr fen Sie den Initiator Node Namen 4 Das LUN an ein R5 UDV verbinden Geben Sie in das Hostfeld den Initiator Node Namen ein 5 Die Konfigurationseinstellungen fur das Volume sind abgeschlossen 6 berpr fen Sie die iSCSI Einstellungen Die IP Adresse des iSCSI Data Ports 1 lautet 192 168 11 229 Port 2 ist 192 168 12 229 z B 7 Fugen Sie Target Portals beim Microsoft iSCSI Initiator 2 03 hinzu 8 Geben Sie die IP Adresse des iSCSI Data Port 1 ein 192 168 11 229 wie auf der vorigen Seite angegeben Fur MC S gibt es in der Registerkarte Discovery nur EIN Target Portals iSCSI Initiator Properties General Discovery Targets Persistent Targets Bound Volumes Devices Target Portals 1321641129 360 otal Rome Bem o iech ONS Seren d Hemave Fleftesh 0K Cancel Abbildung F 24 9 Loggen Sie sich ein 118 Abbildung F 25 10 Klicken Sie dann auf Advanced Log On to Target CUT ea a i 1 ey tat Abbildung F 26 11 Wahlen Sie die Einstellung f r Local Adapter Source IP und Target Portal als iSCSI Data Port 1 192 168 11 229 aus 119 CHAP
68. size Type TrapReceiver Fie Folder PF failure bat 1KB MS DOS Batch File Erstellen Sie eine Batchdatei mit folgender Syntax net send lt computer name gt lt message gt failure bat Notepad Le EI amp File Edt Format Views Help net send pm4 failure RAID System Computer Name 91 1 1 3 Netzwerkverbindungen 1 L6sungsweg Deaktivieren Sie die Windows Firewall Si Windows Firewall General Exceptions Advanced Your PC is not protected turn on Windows Firewall Windows Firewall helps protect your computer by preventing unauthorized users from gaining access to pour computer through the Internet or a network Y C On recommended This setting blocks all outside sources from connecting to this computer with the exception of those selected on the Exceptions tab Don t allow exceptions Select this when you connect to public networks in less secure locations such as airports rou will not be notified when Windows Firewall blocks programs Selections on the Exceptions tab will be ignored 2 00 not recommended Avoid using this setting Turning off Windows Firewall may make this computer more vulnerable to viruses and intruders What else should know about Windows Firewall Cancel Alternative Konfigurieren Sie in der Firewallkarte General Exceptions Advanced Exceptions Unblocking Port 162 Si Windows Firewall
69. spaces on RAID levels 0 1 3 5 6 Quick install function will occupy all residual VG space for one UDV and it has no space for snapshot QSnap and spare If snapshot QSnap function is needed please create volumes by manual and refer to section 4 4 for more detail GeViRAID Quick Install function has a smarter policy When the system is inserted with 8 HDD or 16 HDD and all HDD are in the same size GeViRAID Install function lists all possibilities and sizes among different RAID levels Quick Install will use all available HDD for the RAID level which user decides But when the system is inserted with different sizes of HDD e g 8 200G HDD and 8 80G the controller also lists all possibilities and combinations of different RAID Level and different sizes After user chooses 21 full RAID level user may finds there are still some HDD are not used Free Status The result is from GeViRAID s smarter policy on Quick Install which gives user 1 Biggest capacity of RAID level which user chooses and 2 The fewest disk number for the RAID level volume size E g user chooses RAID 5 and the controller has 12 200G HDD 4 80HDD inserted Then if using all 16 HDD for a RAID 5 then the volume max size is 1200G 80G 15 But in GEVIRAID controller we do smarter check and find out the most efficient use of HDDs which results controller only use the 200G HDD Volume size is 200G 11 2200G Then the volume size is bigger and full u
70. write SES Enable e Disable e Figure 3 7 1 1 Figure 3 7 1 1 Enable SES in LUN 0 and can be accessed from every host The SES client software is available at the following web site SANtools http www santools com 3 7 2 Hardware monitor Enter Hardware monitor function to view the information of current voltage and temperature 61 Enclosure management Hardware monitor Item Information 1 3W 1 52 V min 1 44 V max 1 53W 3 3W 3 28 V min 3 10 V max 3 55 V 5W 5 02 V min 4 80 V max 5 35 V 12 12 08 V min 11 40 V max 12 80 v 2 5V 2 54 V min 2 45 V max 2 75 V PSU 5ViBackplane 5 10 V min 4 70 V max 5 35 V PSU 12V Backplane 12 23 V min 11 40 V max 12 80 VW PSU 3 3V Backplane 3 31 V min 3 10 V max 3 55 VW Daughter Board 43 0 C hyst 0 0 Ch high 70 0 CH PCI X BRG 33 5 C hyst 40 0 C high 60 0 CH Core Processor 46 0 C hyst 0 0 C high 75 0 ICH Location 1 Backplane 29 0 C hyst 0 0 C high 45 0 ICH Location 2 Backplane 29 0 C hyst 40 0 C high 45 0 CH Location 3 Backplane 29 5 C hyst 0 0 C high 45 0 ICH PSU1 Backplane good PSU Backplane good FAN I Backplane good FAN2 Backplane good FANS Backplane good Auto shutdown Figure 3 7 2 1 lf Auto shutdown has been checked the system will shutdown automatically when volta
71. xtend html 2 3 Management methods Das GeViRAID II bietet 3 Wege zur Konfiguration und berwachung Diese wer den im Folgenden beschrieben 2 3 1 Web GUI GeViRAID II Controller unterst tzen grafische Benutzeroberfl chen f r die Sys temsteuerung Vergewissern Sie sich dass das LAN Kabel angeschlossen ist Die Standard Einstellung der Management Port IP ist DHCP die DHCP Adresse wird auf dem LCM angezeigt der Benutzer kann f r die IP zuerst LCM ausw hlen und dann den Browser ffnen um die DHCP Adresse einzugeben Die DHCP Adresse ist dy namisch und der Benutzer muss sie vielleicht nach jedem Neustart nochmalig Uber 12 pr fen Wenn das DHCP Service nicht verf gbar ist nutzen GeViRAID Il Controller zero config Zeroconf um eine IP Adresse zu erhalten Z B auf dem LCM 192 168 201 150 GEUTEBR CK GeViRAD2 lt http 192 168 201 150 or https 192 168 201 150 https Verbindung mit verschlusselten Secure Sockets Layer SSL Bitte beachten Sie dass https Verbindungen langsamer als http sind Klicken Sie auf einen der Men punkte auf der linken Seite werden Sie aufgefordert sich anzumelden Login name admin Default password start 2 3 2 RS 232 Serieller Port Benutzen Sie ein Nullmodem Kabel f r die Verbindung zum Konsolenport des GeViRAID Il Die Einstellungen sind Baud rate 115200 8 Bits 1 Stopp Bit und no Parity Terminal Type vt100 Login Name admin Default Pa
72. 002 Ta nn fil Fr 3 055 D 3 BEE BS Good S E e SU ZCGCHI3 23703 Hl d AG emgeet D en 2 DtGb d Sr Goad u zi 0600137938002 74 VWG Rp H oh 3 0Gb 8 e Good m N 2070001372364002 74 YG R6 u D on 3 0Gb a 3 j Goad a r 2076001374364002 Z VK a_i D no 3 0G5b 10 Gand B n 072001372564002 da iii H re 205b 11 __ Good Ei 5 2072001372364003 74 VG Rp amm fl pa 3 00b 12 Hi Goad 2074001378356002 T4 fil Fa 3 06b 13 o NEEN i Good gen Fi a 2075001374383002 d eigene fi Fa 3 03b 2 14 are S i Good 7 2076001372384002 74 ami fi Fa 3 03 15 o Good 1 ri m 2077001372364002 74 enden fl Fo 3 055 16 Kr Good a a E D 20001379383002 4 fi Fa 305b Aibo spenden Disables Aree mks a Global spares s Dedicated spares a Abbildung 3 6 2 1 Abbildung 3 6 2 1 Die Physical Disks in Slot 1 2 3 4 sind als VGs genannt VG R0 konfiguriert Physical Disks in Slot 6 7 8 9 sind als VG genannt VG R6 konfiguriert Slot 11 ist definiert als Dedicated Spare Disk der VG VG R6 Die anderen sind Free Disks PD column description Die jeweilige Position der HD Gez hlt wird von links nach rechts Mit dem blauen Schalter neben der Slotnummer k nnen Sie weitere Details zu den einzelnen Festplatten einsehen World Wide Name Size GB Kapazit t der Festplatte 35 VG Name Name der Volume Group den Sie vergeben haben Der Festplattenstatus GOOD gt Die Festplatte ist in Ordnung DEFECT gt Die Festp
73. 010 iSCSI Port Alias Name qlogic 1 HBAISCSIName qsan qa222 end targets Vendor Not Available Product Revision Not Available Product ID Not Available Target Alias Name Not Available Target iSCSIName Not Available ML i Send targets host 192 168 11 210 Figure G 1 2 Click Target settings Then select the target and click Config Parameters ANsurfer iSCSI HBA Manager File Host View Wizard Help S Connect Refresh QLOGIC V Host qsan qa222 2 7 HBA 0 GE 0 Rei HBA Model QLA4010 iSCSI Port Alias Name qlogic 1 amp Por Het eg Send targets State IP Address Ves THE Ais WA HBA iSCSI Name qsan qa222 Greyed out entries are Potential Boot devices and cannot be modified Target Configuration a saved blank iSCSI Name will issue a SendTargets command Disable of Auto discover does not apply to SendTargets with CHAP entries Only 64 devices can be persisted bound Any changes made to devices not bound will not persist across card resets Note Right click on entry for additional features Auto bind Discovered Targets Auto discover Re discover prior SendTargets on save l Enable Dynamic IP Address Port iSCSI Name Target ID Alias O g 1000 ONA 0 Reserved for FastiUT S NA R NA P NA ANA ReservedforFastl T 192 168 11 210 aaen TH Mo Connection Active Port 0 glogic 1 Figure G 2 127 3 Di
74. 104 17 Click Advanced Log On to Target Bop 2004 08 bw Com Oe ap D hat Le default Large SI 3 DDR Figure E 18 18 Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Advanced Settings g autnenticaton beween jection Ta Use i specii the same targe lar secret that was conhgqured ar the target for thts Initiator Username angebsecret gt 7 Beam mutual authentication ouse mutua CHAR specii arn mitiator secret on the Ihitiator settmgs page and contigure that secretam the target SE 105 Figure E 19 19 The setting is completed iSCSI Initiator Properties General Discovery Targets Persistent Targets Bound Yolumes Devices Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and devices for that target Targets ign 2004 06 tw cor gsan pb c b3calO0l e def Connected Figure E 20 20 Run Computer Management in Windows Make sure the disks are available Then the disks can be tested for performance by IOMETER E Computer Management el File Action View Window Help Sie 2l AX E as Computer Management iLocal Walume Layout Type File System Status Capacit lf System Tools ERC Partition Basic NTFS Healthy 19 53 GB EREA Event viewer E304 TOOLS Fy Partition Basic FATS Healthy 15 88 GB SE s
75. 5 00m macrosoft demo D Read wr e RS l Sasson Attach B Detach D Abbildung F 6 6 berpr fen Sie die iSCSI Einstellungen Die IP Adresse des iSCSI Data Ports 1 lautet 192 168 11 229 Port 2 ist 192 168 12 229 z B System config SCSI GM e Authentication e No Port Aggregation DHCP TP address Netmask Gateway MTU MAC address ric rea ei e e 1500 wen 1 LAN 192 168 11 229 222 202 239 0 192 168 11229 H 00 13 78 00 02 09 PO EN 192 168 12 254 1500 2 LAN e e 192 168 12 229 255 253 235 0 e d 20 13 78 00 02 01 Enbty name ign 2004 08 com gsanip1i20c 000s00021 SMS D Authentication Abbildung E 7 Fugen Sie Target Portals beim Microsoft iSCSI Initiator 2 03 hinzu 109 S051 Ingo Properties Abbildung F 8 8 Geben Sie die IP Adresse des iSCSI Data Ports 1 ein 192 168 11 229 wie auf der vorigen Seite angegeben i Vi UL Abbildung F 9 9 F gen Sie das zweite Target Portal in Microsoft iSCSI Initiator 2 XX hinzu 110 SCS Initiator Properties Abbildung F 10 10 Geben Sie die IP Adresse des iSCSI Data Ports 2 ein 192 168 12 229 wie auf der vorigen Seite angegeben Bach Target Portal Abbildung F 11 11 Die Initiator Einstellung ist abgeschlossen 111 SC St Initiator Properties EC fo Abbildung F 12 12 Loggen Sie sich ein iSCSI Initiator Properties Ist A Sera t
76. 59 4 2 VG Migration und Expansion e ansnnensnnnnennnnenrnrnnnn 60 4 3 UDV Enweterung 62 4 4 Snapshot QSnap Rollback cece sees eeeeeeeeeees 64 4 4 1 Einrichten eines Snapshot QSnap Volume ees 65 4 4 2 Automatischer Snapshot CGnap 66 4 4 3 Eeleren 67 4 5 QCopy Remote Replikation cccccccecceecseeeeeeeeeees 67 4 6 Disk TON Ge en a een 70 4 Unterst tzung von Microsoft MPIO and MC S 71 a 1 Tu e BE 72 A Zetrifzierungdsleie cece cecceeceeeeeeeeeteeceeeeeeceeeeeaeeeees 72 B Ereignis und Fehlermeldungen cscseceseeeeees 76 C Bekannte Probleme ccccceccecceeceeceeeseceeeeeseeeeees 79 D Security Alarm Relais Konfiguration SNMP 81 E Microsoft iSCSI Initiator annnnnennanennnnennnnnnnnnnnnnnnnnn 94 F Trunking LACP Setup Anletung 98 G MPIO and MC S Setup Anleitung 107 H Installationsschritte f r gro e Volumen TB 123 Kapitel 1 RAID Einf hrung 1 1 Eigenschaften Das GeViRAID Il besitzt einen high performance RAID Controller e Backplane Ausf hrung GEVIRAID Il Gigabit LAN x2 to SATA II xN bays RAID controller GeViRAID II Controller Eigenschaften e RAID 6 ready e Snapshot on the box QSnap Rollback e QCopy Remote Replikation e SATA II Unterst tzung kompatibel zu SATA I e N way Spiegelung e Kapazitatserweiterung im laufenden Betrieb und RAID Level Migration e
77. 595 255 0 m m 00 13 78 00 02 01 Entity name iqn 2004 08 tw com qsan p120c 000a00021 ISNS e Authentication a Figure E 7 7 Select Trunking If LACP is needed please see Figure E 12 System config iSCSI Aggregation Multi homed LAN1 Aggregation Trunking LACP ze Back 5 Confirm e Figure E 8 Now the setting is in Trunking mode 99 System config SCSI NS e Authentication e No Port Aggregation DHCP IP address Netmask Gateway MTU MAC address Trunking no aenn 1500 L lagd a 192 168 11 229 232 255 232 0 192 168 11 229 a 00 13 78 00 02 00 Entity name iqn 2004 08 bw com gsan p120c 000300021 ISNS a Authentication e Figure E 9 9 Enable switch Trunking function of port 21 and 23 Below is an example of Dell PowerConnect 5324 Go to Figure E 14 for next step E Dell OpenManage Switch Administrator Microsoft Internet Explorer Ele Edt View Favorites Tools Hel D sch CH Isi iz Gei gt Search gt Favorites e Oe E er al Address hetp 192 168 10 252 Dell OpenManage Switch Administrator Support Help About Log Out DEL L Powrerconnect 5324 d 92 1 68 10 252 LAG Membership E Home He System LAG Membership 7 aani Network Securit i meet H 10 11 12 13 14 15 16 17 18 19 20 21 Z2 23 24 Figure E 10 10 Select LACH If Trunking is needed please see Figure E 8 100 System config iSCSI Aggregation multi
78. 7 Mail Select Mail to enter at most 3 mail addresses for receiving the event notification Some mail servers would check Mail from address and need authentication for anti spam Please fill the necessary fields and select Send test mail to check whether the email works fine User can also select which levels of event logs are needed to be sent out by Mail Default setting is only ERROR and WARNING event logs enabled 26 system config Mail Mail from address malman controller Mail to address 1 Send events 1 INFO WARNING ERROR M Mail to address 2 Send events 2 INFO WARNING M ERROR M Mail to address 3 send events 3 INFO WARNING M ERROR M SMTP relay C SMTP server Authentication None E Account Password Confirm Send test mail a Figure 3 4 7 1 3 4 8 SNMP Select SNMP to set up SNMP trap for alert via SNMP It allows up to 3 SNMP trap addresses Default community setting is public User can choose the event log levels and the default value of SNMP is INFO event log enabled only System config SNMP SNMP trap address 1 SNMP trap address 2 SNMP trap address 3 Community public Send events INFOM WARNING ERRORE Figure 3 4 8 1 There are many SNMP tools The following web sites are for reference 21 SNMPc http www snmpc com Net SNMP http net snmp sourceforge net 3 4 9 Messenger Select Messenger to set up pop up message a
79. 9 Attach LUN Z Volume config User data volume Attach Create e Delete D Size R YG CY No Name GE status 1 2 3 a RAID LUN SE MB SE 1 UDO 2793 Online fi we A HI i ki Se S Pe sw Mr i RAIDS 0 VGOl 136 Attach e Create e Delete E Figure H 11 134 Volume config User data volume Attach i Yolume config User data volume Attach UDV UDV01 2793G8 E UDY uowoi 12793GB sl BER Bus S ds zl Host i SCSI ID o E LUN 0 LUN o Permission Read only fe Read write Figure H 12 Figure H 12 Left P series Right S series attach LUN Step B configure your host server 1 For S Series controller SCSI the host server side may need reboot or setup SCSI HBA BIOS to make volumes available Please refer to your SCSI HBA manual for more detail For P Series iSCSI user needs to setup software iscsi initiator or iSCSI HBA first 2 Below is the configuration for Windows Server 2003 R2 with Microsoft iscsi initiator Please install the latest Microsoft iscsi initiator from below link http www microsoft com downloads details aspx FamilyID 12cb3c1a 15d6 4585 b385 befd1319f825 amp DisplayLang en iSCSI Initiator Properties iSCSI Initiator Properties Ka SE Type the IP address or DNS name and socket number of the portal you General Discovery Targets Persistent Targets Bound Volumes Devices The iSCSI protocol uses the following in
80. 93202d9 Ja VG RS 5 I 201a0013739320249 38 are D 202400137 8000108 35 T E P 20100137 bavoed9 33 ba C 2 201b001373320299 33 Abbildung 3 6 7 7 Abbildung 3 6 7 7 Slot 5 ist definiert als global spare Disk Schritt 5 Fertig nun k nnen Sie sie als SCSI Devices nutzen Ga Goaod Good Lemari Good Good Good Good EN cated spares a 1 2 Speed D rp 1 556 fi pn 1 556 DH pp 1 56h A ro 1 3150 H Ge 1 566 Al FR 1 566 FR 1 5Gb fl Fe L Sch Um die UDV und VG zu l schen folgen Sie den nachstehenden Anweisungen Schritt 6 Trennen Sie die LUN vom In Volume config Logical unit Host 41 a ign 1991 05 microsoft com demo UDV Permission Read write Read write Abbildung 3 6 7 8 Attach UDY name Attach UDV R3 1 UDV RS 2 Detach Session 1 m Detach e 1 Wahlen Sie durch Anklicken der Auswahlbox in der jeweiligen Reihe die LUNs aus dann klicken Sie auf eine Best tigung angezeigt W hlen Sie OK Fertig w N Schritt 7 L schen eines UDV User Data Volume So gehen Sie vor Detach In einem Popup Fenster wird 1 Gehen Sie zu Volume Config User Data Volume 2 Wahlen Sie durch Anklicken der Auswahlbox in der jeweiligen Reihe die UDVs aus 46 3 Klicken Sie auf Delete In einem Popup Fenster wird eine Bestati gung angezeigt 4 Wahlen Sie OK 5 Fertig Die UDVs sind nun gel scht Tips L schen Si
81. Anzeige More Information Dort wer den Details der Volume Group angezeigt Name der Volume Group Der Schalter neben den Namen f hrt zur Funktion Rename Total GB Gesamte Kapazit t dieser Volume Group Free MB Freie Kapazit t dieser Volume Group mn Anzahl der Physical Disks in dieser Volume Group UDV Anzahl der User Data Volumes die auf diese Volume Group zugreifen Status der Volume Group Online gt die Volume Group ist online Fail gt bei dieser Volume Group ist ein Fehler aufgetreten DG gt DeGrade Mode Diese Volume Group ist nicht kom plett Grund daf r k nnte eine fehlende Diskette oder ein Diskfehler sein R gt Rebuild Diese Volume Group befindet sich im Re build Status3 M gt Migration Diese Volume Group wird gerade migriert Der RAID Level der Volume Group Die Taste neben dem RAID Level ffnet die Migrate Funktion Wenn Sie Migrate anklicken k nnen Sie Disks f r eine Erweiterung hinzuf gen oder den RAID Level der Volume Group ndern VG operations description Erstellt eine Volume Group L scht eine Volume Group 38 3 6 4 User data volume In der User Data Volume Funktion konnen Sie den Status jedes UDV Uberwachen Attach aaps nat aata P Size R TT Snapshot YG CN Wo Name e Status i 2 3 RAID LUM el eo te DOL 30 wo Du 9 99 10 00 3 b cmon RAIDO 1 e VGRO 663 2 U 02 20 10 00 10 00 m S au L
82. Ausf hrung von Datenverkehr zuge ordnet Jedes CV kann dabei je nach Konfiguration durch den User eine andere Gr e be sitzen LUN ist die logische Einheit Laufwerk auf das der User per SCSI zugreifen kann 3 6 2 Physical disk Gehen Sie in Physical Disk wenn Sie sich den Status der im System befind lichen Festplatten ansehen m chten Hierein paar Tipps zur Handhabung 1 Mehrfach Auswahl W hlen Sie eine oder mehrere der Kontrollk stchen links der Slot Nummer Um alle Laufwerke auszuw hlen klicken Sie auf das Kon trollk stchen in der oberen linken Ecke Um die Auswahl aufzuheben klicken Sie ein zwei tes Mal darauf 2 Das Auswahlfenster steht nicht zur Verf gung wenn kein VG eine VG mit RAID 0 oder JBOD definiert ist F r diese RAID Levels k nnen keine Spa redrives eingerichtet werden 3 Die drei Funktionen Free disc Global spares Dedicated spares k n nen auch mit Mehrfachauswahl genutzt werden Die Bedienung der weiteren Seiten z B Volume Config of VG UDV CV LUN pages ist vergleichbar mit den vorgenannten Schritten 34 Free disks Global spares Dedicated spares e Gize VC Slot WTA ca CS Status 1 d Speed 1 em od e 2071001379383002 74 WORD aa A ep 3 056 2 S Good L 207c00 13783583002 fa WORD D ap 3 056 3 a BEN ee Good DE E 20 7600137838 00 Z i VC AL weer D aD wll 06Gb 4 L Good C G 207800137 8a8s002 Z WORD memes D ap 3 0Gb 3 Good D e 2079001379342
83. CP setting can be changed by clicking the button o Aggregation ex iSCSI config NIC Aggregation Aggregation Trunking LACP Address 192 168 1 1 Mask EEN Gateway 192 168 1 254 NIC O ani O cane O Lana O Lana Figure 3 5 2 5 Figure 3 5 2 5 P200C there are 4 iSCSI data ports select at least two NICs for link aggregation iSCSI config NIC Aggregation Aggregation Trunking LACP Address 192 168 10 73 Mask 233 273 2AT Gateway 192 168 10 2 54 NIC I tani I Lan Figure 3 5 2 6 Figure 3 5 2 6 P150C there are 2 iSCSI data ports select two NICs for link aggregate 33 Name LAG LAG No DHCP IP address Netmask Gateway MTU MAC address Link Trunking no 192 163 1 254 1500 LANI u e 192 168 1 1 255 255 255 0 e 00 13 78 36 00 50 down Trunking no 192 168 1 254 1500 LAN m 0 192 158 1 1 255 255 253 0 e e 00 13 78 46 00 60 down LAP no 192 168 3 25 4 1500 LAN e L e 192 168 3 1 255 255 253 0 e m 00 13 78 36 00 62 down LAP no 192 168 3 254 1500 L ANA 1 2 1927 166 5 1 295 299 295 0 m ii 00 13 78 36 00 62 down Figure 3 5 2 7 Figure 3 5 2 7 P200C LAN1 and LAN2 set as Trunking mode LAN3 and LAN4 set as LACP mode Take an example of P200C LAN1 and LANZ set as Trunking mode LAN3 and LAN4 set as LACP mode To remove Trunking LACP setting can click the button g in the LAG column and then will pop up a message to confirm This method is the same as P150C
84. Check the parameters which Initial R2T are enabled 2 qsan qai Target Parameters Immediate Execution TargetlD iti Data Throttle aE Tae T 2 D LJ DEIER EE EE EE EC Figure G 7 8 Check Target Information again and the state changed to Session Active SANsurfer iSCSI HBA Manager SE lej x File Host View Wizard Help Q Connect Refresh QLOGIC 1 Target Information LUN List HBA Model QLA4010 iSCSI Port Alias Name glogic 1 HBA iSCSI Name qsan qa22 Vendor QSANTech Product Revision 0 9 Product ID P60C Target Alias Name Not Available Target iSCSI Name iqn 2004 08 tw com qsan p60c O000000d4 default target Device iqn 2004 08 tw com qsan p60c 0000000d4 default target Figure G 8 9 Then run Computer Management in Windows Make sure the disk appears 130 EI Computer Management i Fie Action wiew Window Help Volume Layout Type File System Status Capacit Computer Management Local H d System Tools GIE Partition Basic MTFS Healthy 19 53 GB BAH Event viewer 304 TOOLS Fi Partition Basic FAT32 Healthy 15 88 GB EL x Shared Folders EIWINDOWS2003 D Partition Basic FAT32 Healthy Book 19 52 GB Ha Local Users and Groups windows 2000 ECO Partition Basic NTFS Healthy System 19 53 GB Device Manager e 5 Storage ea Removable Storage ee Disk Defragmenter SS Disk Management Ei G S
85. DDR 400 ECC with Sam sung AT AB28L72Q8SHC4S 1GB DDR 400 ECC Reg with Samsung Unigen UG732D6688KN DH 256MB DDR 333 Unbuffered with Hynix n P wa Gemenge 256MB DDR 333 ECC Reg with Elpida Unigen UG764D7588KZ DH 512MB DDR 333 ECC Reg with Elpida ner 1GB DDR 333 ECC Reg with Hynix Unigen UG7128D7488LN GJF 1GB DDR 400 ECC with Hynix Pam egtiemgegteg 1GB DDR 400 ECC Reg with Hynix a ne 1GB DDR 400 ECC Reg with Elpida Unigen UG732D6688KS DH 256MB DDR 333 Unbuffered Low profile with Hynix Unigen UG764D6688LS DH 512MB DDR 333 Unbuffered Low profile with Hynix P150C P200C RAM Spec 240 pin DDR2 533 PC4300 Reg register or UB Unbufferred ECC up to 2GB 64 bit data bus width and also 32 bit mem ory support x8 or x16 devices 36 bit addressable up to 14 bit row address and 10 bit column address eS eee eee ae fs 1GB DDR2 667 Unbuffered non ECC with SEC ATP sO AJ228K72G 8BHE6S 1GB DDR2 667 Unbuffered ECC 72 with SEC MU ES AJ64K72F8BHE6S 512MB DDR2 667 Unbuffered ECC with SEC AJ56K72G8BJE6S 2GB DDR2 667 Unbuffered ECC with Samsung Unigen UG64T7200L8DU 6AL 512MB DDR2 667 Unbuffered ECC with Elpida aa 5AM 1GB DDR2 533 Unbuffered ECC with Elpida ee eee 1GB DDR2 533 Registered ECC with Elpida Unigen UG25T7200M8DU 5AM 2GB DDR2 533 UnBuffered ECC with Micron ISCSI Initiator Software OS Software Releas
86. G or only VG of RAID 0 JBOD Because user cannot set dedicated spare disk for these RAID levels sometimes rebuild is called recover these two have the same meaning The following table is the relationship between RAID levels and rebuild RAID 0 Disk striping No protection of data VG fails if any hard drive fails or unplugs Disk mirroring over 2 disks RAID 1 allows one hard drive fails or unplugging Need one new hard drive to insert to the system and rebuild to be completed N way Extension to RAID 1 level It has N copies of the disk N way mirror mirror allows N 1 hard drives fails or unplugging RAID 3 Striping with parity on the dedicated disk RAID 3 allows one hard drive fail or unplugging Striping with interspersed parity over the member disks RAID 5 allows one hard drive fail or unplugging 2 dimensional parity protection over the member disks RAID 6 allows two hard drives fails or unplugging If it needs to rebuild two hard drives at the same time it will rebuild the first one then the other by sequence RAID 0 1 Mirroring of the member RAID O volumes RAID 0 1 allows two hard drives fails or unplugging but at the same array RAID 10 Striping over the member RAID 1 volumes RAID 10 allows two hard drives fails or unplugging but at different arrays RAID 30 Striping over the member RAID 3 volumes RAID 30 allows two hard drives fails or unplugging but at different arrays ie ef RAID 50 Striping ove
87. GB 17 0166 87 No Us z Event viewer Sip Partition Basic FATS Healthy Boot 19 52 G6 16 3268 63 No 0 SL F Shared Folders GIE Partition Basic Healthy 19 53GB 19 53GB 100 No 0 Local Users and Groups Ba Partition Basic NTFS Healthy 18 08 G6 16 40GB 90 No 0 E Performance Logs and Alert Lien os 2939 2 G Partition Basic UDF Healthy 3 2066 OMB 0 No 0 a bs Device Manager Et CH Storage d Removable Storage BE 4 Disk Defragmenter Se Disk Management a 4 Services and Applications Disk 0 Basic LC D E F 76 68 sb 13 53 ab FAT3Z 19 53 GB FAT3Z 19 53 GB 18 05 GB NTFS Online Healthy System Healthy Book Healthy Healthy Disk 1 Unknown 2792 Kei GB Nat Initialized Sco romo DvD EN OS 2939 2 G3 3 20 GB 3 20 GB UDF Online Healthy Figure H 17 3 Initialize disk 137 BEN REES DES D E E 19 53 GB FAT3Z 19 53 56 15 05 GB NTFS Healthy Boot Healthy Healthy Disk 1 LC 19 53 GB FATS2Z Healthy System Unknown oe oe ep PELE Mot Initialized Properties CD ROM 0 DVD 3 20 G6 Online Help 3 20 GB UDF Healthy Figure H 18 4 Convert to GPT disk for over 2TB capacity For more detail information about GPT please visit http www microsoft com whdc device storage GPT FAQ mspx LP Disk 0 Basic C Dz E F 76 66 GB 13 53 GB FAT32 19 53 GB FAT32 19 53 GB 16 08 GB NTFS Online Healthy System Hea
88. GEUTEBRUCK GeVIRAID II SCSI iSCSI GbE to SATA SAS RAID System Installations und Bedienungsanleitung User Manual Microsoft iSCSI Initiator Quick Start GeViScope re_porter GeViRAID II Quick Guide GeViScope re_porter GeViRAID Il IP Adresse der Netzwerkkarte die f r die Verbindung zum iSCSI Port des GeViRAID II zust ndig ist 192 168 1 10 einstellen IP address for the Desktop Network card for use the iSCSI Port connection GeViRAID II input 192 168 1 10 Eigenschaften von Internet Protocol TCP IP aE Allgemein ax beziehen IP Adresse automatisch beziehen Folgende IP Adresse verwenden IP Einstellungen k nnen automatisch zugewiesen werden wenn das Netzwerk diese Funktion unterst tzt Wenden Sie sich andernfalls an den Netzwerkadministrator um die geeigneten IP Einstellungen zu Bevorzugter DNS Server IP Adresse 192 168 1 10 Subnetzmaske 255 Pe e 0 Standardgateway DNS Serveradresse automatisch beziehen Folgende DNS Serveradressen verwenden Altemativer DNS Server Starten Sie Microsoft iSCSI Initiator Run Microsoft iSCSI Initiator version gt H 5 Microsoft iSCSI Initiator Klicken Sie auf Discovery Klicken Sie auf Add Geben Sie IP Adresse 192 168 1 1 ein Click Discovery Click Add Input IP address 192 168 1 1 Eigenschaften von iSCSI Initiator EEE General Discovery Targ
89. IC or iSCSI HBA 4 CAT 5e or CAT 6 network cables for management port and iSCSI data ports Recommend CAT 6 cables for best performance 5 Prepare storage system configuration plan 6 Management and iSCSI data ports network information When using Static IP please prepare static IP addresses subnet mask and default gateway 7 Gigabit LAN switches Recommended or Gigabit LAN switches with VLAN LCAP Trunking functions Optional 8 CHAP security information including CHAP usernames and secrets Optional 9 Setup the hardware connection before power up servers and controllers Connect console cable management port cable and iSCSI data port cables first 2 2 iSCSI introduction ISCSI Internet SCSI is a protocol which encapsulates SCSI Small Computer system Interface commands and data in TCP IP packets for linking storage devices with servers over common IP infrastructures iSCSI provides high performance SANs over standard IP networks like LAN WAN or the Internet IP SANs are true SANs Storage Area Networks which allow few of servers to attach to an infinite number of storage volumes by using iSCSI over TCP IP networks IP SANs can scale the storage capacity with any type and brand of storage system In addition using any type of network Ethernet Fast Ethernet Gigabit Ethernet and combining operating systems Microsoft Windows Linux Solaris etc within the SAN network IP SANs also include mechanisms for secur
90. In P120C Trunking LACP setting can be changed by clicking the button in the Aggregation column iSCSI config NIC Aggregation Multi homed Aggregation C Trunking C LACP Figure 3 5 2 7 Figure 3 5 2 7 P120C select aggregation mode 1 Multi homed Default mode Each of iSCSI data ports is connected by itself and is not link aggregation Select this mode can remove Trunking LACP setting 2 Trunking defines the use of multiple iSCSI data ports in parallel to increase the link speed beyond the limits of any one single port 3 LACP The Link Aggregation Control Protocol LACP is part of IEEE specification 802 3ad that allows bundling several physical ports together to form a single logical channel LACP allows a network switch to negotiate an automatic bundle by sending LACP packets to the peer The advantages of LACP are 1 increases bandwidth 2 failover when link status fails on a port For detailed setup steps please refer to Appendix E Trunking LACP setup instructions 34 Caution In P120C each of iSCSI data ports must be set in different subnet The other models do not have such limitation P100C does not support Trunking LACP feature 3 5 3 Node Single node Multi node Select Node to view the target name for iSCSI initiator P100C P120C P150C supports single node The node name of P100C P120C P150C exists by default and can not be changed Name Auth None ig
91. J DNA 0 eserved for FastlUT CNA DU HA R 0 0 0 0 NA 10 Reserved for FastiUT 192 168 11 210 2280 lr A No Connection Active Config Parameters Config Authentication Port 0 glogic 1 Figure G 5 6 Click Refresh and find a new target with iSCSI name 2 SANsurfer iSCSI HBA Manager File Host View Wizard Help Q XX Connect Refresh QLOGIC EES EEN eo ernten Statistics Diagnostics t Host qsan qa222 mm HBA 0 OLA4010 Rd HBA Model QLA4010 iSCSI Port Alias Name _glogic 1 oF 0 TU glogic 4 State IP Address 4935 AGG Aie M HBAISCSIName gsan qa222 Greyed out entries are Potential Boot devices and cannot be modified Target Configuration a saved blank iSCSI Name will issue a SendTargets command Disable of Auto discover does not apply to SendTargets with CHAP entries Only 64 devices can be persisted bound Any changes made to devices not bound will not persist across card resets Note Right click on entry for additional features Auto bind Discovered Targets Auto discover Re discover prior SendTargets on save iSCSI Name Target ID Alias NA 0 Reserved for Fast UT R 2 NA ae NA ANA ReservedforFastl T ession Active ees 92 168 11 210 3260 S No Connection Active 192 168 11 210 3260 iqn 2004 08tw com 64 S Config Parameters Config Authentication Save Settings um BE Port 0 glogic 1 Figure G 6 129 7
92. Konfiguration f r Global Dediziertes Cache f r jedes einzelne Volume e M A R T Unterst tzung Unterst tzt SES e Microsoft VDS Virtual Disk Service f hig e Disk Roaming e MPIO fahig Initiator Treiber vorausgesetzt e MC S fahig Initiator Treiber vorausgesetzt e Unterst tzt iSCSI Header und data digest e Unterst tzt CHAP Authentifizierung e Unterst tzt Link Verdichtung und Trunking Richtig konfiguriert bietet das GeViRAID II einen hohen Grad an Fehlertoleranz und Ausfallsicherheit im Dauerbetrieb durch Nutzung der GEUTEBRUCK RAID Technologie und modernster Management Funktionen Das GeViRAID II wird ber die SCSI Schnittstelle am Host System angeschlossen Die Konfiguration der unterst tzten RAID Level ist beliebig Das GeViRAID II bietet dem Benutzer zuverl ssigen Schutz der vorhandenen Daten Durch die RAID 6 Funktion k nnen zwei Festplatten gleichzeitig ausfallen ohne dass daraus ein Verlust von Daten resultiert Die Daten k nnen jederzeit von den verbleiben den Festplatten aus den dort vorhandenen Echtdaten und den Parit tsinformationen wieder hergestellt werden Unter Snapshot on the box versteht man eine voll nutzbare Kopie von vorher defi nierten Daten die einen Schnappschuss dieser Daten zu einem bestimmten Zeitpunkt darstellt und somit die schnelle R ckkehr zu einem zur ckliegenden Datenstand erm g licht GEUTEBR CK Snapshot on the box kann bis zu 32 Snapshots f r alle Daten Volum
93. No is More Information indication It shows the 48 rr details of the cache volume Size MB Total capacity of the cache volume The button next to the CV size is Resize function The CV size can be adjusted UDV Name Name of the UDV e CV operations description Create Create a cache volume function Delete Delete a cache volume function If there is no free space for creating a new dedicated cache volume cut down the global cache size first After resized then dedicated cache volume can be created Tips The minimum size of global cache volume is 40MB The minimum size of dedicated cache volume is 20MB 3 6 6 Logical unit number Enter Logical unit function to view the status of attached logical unit number of each UDV User can attach LUN by clicking the Attach Please refer to Figure 3 6 6 1 Host must input an initiator node name for access control or fill in wildcard which means every host can access the volume Choose LUN number and permission then click confirm 7 Please refer to Figure 3 6 6 2 User can assign up to 256 LUNs per system controller For the host connection the host number limitation is 32 per system controller in the same time and 8 for single user data volume UDV which means 8 hosts can access the same UDV in the same time 49 UDY UDY 01 30GB sl Host ji Target ign 2004 08 tw com qsan p200c 000a6d02 1 targeto
94. Physical HW events eee ege Warning ECCerror Warning Single bit ECC error is detected Error Multi bit ECC error is detected Error ECC DIMM Instal Info ECC Memory is installed led Info Non ECC installed Info Non ECC Memory isinstlled m Error Host chip failure Error Host channel chip failed _ _ Error LU Drive chip failure Error Drive channel chip failed Warning Ethernet port failure Warning GUI Ethernet port failed e HDD IO events EEN Warning Disk error TI Error Disk lt slot gt read block error Warning Disk error Error Disk lt slot gt writes block error Warning HDD failure Error Disk lt slot gt is failed Warning Channel error Error Disk lt slot gt IO incomplete e SES events EEE ae Info SES load conf OK Info SES configuration has been loaded Failure SES device is disabled Info SESisdisabled Toto The SES device is disabled Info SES is enabled____ Info The SESdeviceisenabled 76 e Environmental events eae os ca See EEN Admin Login OK Info Admin login from lt IP or serial console gt via lt Web UI or Console UI gt via lt Web UI or Console Ul gt iSCSI data port Info iSCSI login from lt IQN gt lt IP Port Num login ber gt succeeds ie iSCSI data port Warning iSCSI login from lt IQN gt lt IP Port login reject Number gt was rejected reason of 1 initiator error 2 authentica
95. RAID LUN GB name MB i UDV RO 10 Bwe HHI 0 00 0 00 oO e s ns e Gr 58 RAIDS 0 gt VGRO 100 Attach e Snapshot Create e Delete e Figure 4 3 2 Figure 4 3 2 Extend UDV RO from 5GB to 10GB ae fc Tips The size of UDV extension must be larger than original Caution UDV Extension cannot be executed during rebuild or migration 4 4 Snapshot QSnap Rollback GeViRAID Snapshot on the box QSnap captures the instant state of data in the target volume in a logical sense The underlying logic is Copy on Write moving out the to be written data to certain location whenever a write action occurs since the time of data capture The certain location named as snap UDV is essentially a new UDV which can be attached to a LUN thus provisioned to a host as a disk just like other ordinary UDVs in the system Rollback function restores the data back to the state of any point in time previously captured for whatever unfortunate reason it might be e g virus attack data corruption human errors and so on Snap UDV is allocated within the same VG in which the snapshot QSnap is taken we suggest to reserve 20 of VG size or more for snapshot QSnap space Please refer to Figure 4 4 1 for snapshot QSnap concept P120C P150C P200C supports snapshot rollback P100C does not have this feature 74 Osan or F series Osan 5 or P sames Osar 5 or F series Coo Working Volume anapshot Volumes 2pm
96. RAID row 1 One RAID 10 volume over 3 4 disk RAID 1 volume RAID width 1 RAID copy 4 RAID row 3 Write Through Cache Strategie Der Abschluss der Schreiboperati on wird erst best tigt wenn die Daten auf nicht fl chtigen Spei cher HDD geschrieben wurden Die Daten werden nicht geca ched Write Back Cache Strategie Die Schreiboperation wird best tigt sobald die Daten im fluchtigen Cache Speicher angekommen sind Der tatsachliche Schreibvorgang auf HDD findet zu einem sp teren Zeitpunkt statt Die Geschwindigkeit des Systems wird dadurch erh ht jedoch besteht dadurch bei pl tzlichem Stromaus fall die Gefahr von Datenverlust Beschr nkt den Volume Zugriff auf Nur Lesen Read Onl Dedicated Spare disks The spare disks are only used by one specific VG Others could not use these dedicated spare disks for any rebuilding purpose disks pool for such requirement Dedicated Cache DeGrade Modus Ein Laufwerk aus einer VG ist ausgefallen aber Daten k nnen weiterhin gelesen und geschrieben werden Global Spare disks GS is shared for rebuilding purpose If some VGs need to use the global spare disks for rebuilding they could get the spare disks out from the common spare World Wide Name Host Bus Adapter Multi Path Input Output wes o Mehrfach Vebindungen pro Sitzung ses SCSI Enclosure Services wen Internet Small Computer Systems Interface Lace Link Aggregation Control Protocol Maximum Transm
97. RENE RE EE RER EE EE EE EE EE EE RER EE 1 381 41 22 String ERROR Sat 02 Sep 2006 00 29 LE Peowell homer Suppli out of work Eine Popup Benachrichtigung wie die nachfolgend abgebildete Nachricht wird nun Uber den Windows Messenger verschickt und abgebildet 93 E Microsoft iSCSI Initiator Es folgt schrittweise die Vorgehensweise f r das Setup des Microsoft iSCSI Initiator Bitte besuchen Sie die Microsoft Webseite f r den aktuellsten iSCSI Initiator Das fol gende Setup verwendet wom glich nicht den aktuellsten Microsoft iSCSI Initiator 1 Starten Sie Microsoft iSCSI Initiator Version 2 03 Bitte sehen Sie sich Abbildung D 1 hierf r an 2 Klicken Sie auf Discovery iSCSI Initiator Properties BR E d x General Discovery Targets Persistent Targets Bound YallmesDewces The C5 protocol uses the folowing information to uniquely Wlect u iz initiator and authenticate targets lrehabor Node Name vn 1001 DD com mmerosoft deme To rename the irmialor node click Change Change To authenticate targets using CHAF click Secrat to o specty a CHAP secret acre To configure IPSec Tunnel Mode addresses click Tunnel Tune Abbildung D 1 3 Klicken Sie auf Add Geben Sie IP Adresse oder den DNS Namen der ISCSI Speicher Device ein Bitte sehen Sie sich Abbildung D 2 4 an Add Target Portal Type the IP address or DNS name and socket number of the portal you wank to add Cli
98. RPM SATA 3 0Gb s 16M igi Caviar RE16 WD5000AAKS 500GB 7200RPM SATA 3 0Gb s 16M Westem Digi RE2 WD5000ABYS 500GB 7200RPM SATA 3 0Gb s tal 16M NCQ P200C supports SAS disk Vendor Model EE era ee Fujitsu MAX3036RC 36 7G 15000RPM SAS 3 0Gb s 16M Fujitsu MAX3073RC 73 5G 15000RPM SAS 3 0Gb s 16M Fujitsu MAX3147RC 147 0G 15000RPM SAS 3 0Gb s 16M Hitachi Ultrastar 15K147 HUS151436VLS300 36G 15000RPM SAS 3 0Gb s 16M eee Westem Digi D On D 3 g Q co lt oS D GU D 3 g Q S S D Een D 3 g 9 S D D QD a D D 3 3 g J amp amp 3 0Gb s 8M 3 0Gb s 16M 3 0Gb s 16M 75 Seagate Cheetah NS ST3400755SS 400G 10000RPM SAS 3 0Gb s 16M Some of SAS commands in Fujitsu SAS disks do not follow SAS standard Al though QSAN controller has workaround this problem Fujitsu SAS disks are not recommended B Event notifications e PD S M A R T events eS SS EE ae eae Info Disk inserted Info Disk lt slot gt is inserted Info Diskremoved__ Info Disk lt slot gt is removed S M A R T thresh Warning Disk lt slot gt S M A R T threshold ex old exceed condi ceed condition occurred for attribute of tion read error rate spin up time reallocated sector count seek error rate Spin up retries Calibration retries S M A R T infor Warning Disk lt slot gt Failure to get S M A R T mation information e
99. Snap QCopy S i Yes S spindown S 2 Ye Ye SAF TE Table of Contents Chapter 1 RAID introduction 2 22 20 00000 000 n0n nn 6 1 1 RT D 1 2 erminology rset cn ccteretnttoetcex te engacanssenaneasaseessannsanensceanadseusesss T 1 3 RAID levels een nee 10 1 4 AT 11 Chapter 2 Getting started 2u 200n00n0nnunnnnnunnn 12 2 1 Before SIAL NG MR 12 2 2 ISCSI introduction 0 ccc eee ecc cece eeceeeeeceeeeeeseeteeeeeeeeeneees 12 2 3 Management methods cccccceeceeceeeeeeeeeeeeeeeeeeeeees 14 2 3 1 Ve E EA ee ne ee eee ee ante 14 2 3 2 Console serial port nenne ee eine 15 2 3 3 Remote control secure Shell ke 15 2 4 ENBLOSUT One eine 15 2 4 1 Be E 15 2 4 2 ON EE 17 2 4 3 e EE 17 Chapter3 Web GUI guideline 220 22 20020020 19 3 1 P series GUI berarchy 19 3 2 ESO GIN an nn ne a ne a 20 3 3 Quick i e nenne ea 21 3 4 System configuration u2202202200enennennennnsnnennennenenn 23 3 4 1 VOM HAIE ee 24 3 4 2 BUS een een nee ee nee ee en ae dere nee 24 3 4 3 Bee eb e 24 3 4 4 Beien CON IO ee E 25 3 4 5 E E EE 25 3 4 6 RE 26 3 4 7 VE E 26 3 4 8 See 27 3 4 9 Ee E 28 3 4 10 System lee 28 3 4 11 Event Eege 29 3 5 Kier COME G EE 30 39 1 EMI elen seen innen bene nannte nenne ae areas 30 320 2 Ve 30 3 98 IN On ee ee 39 3 9 4 EE ee 38 3 5 5 CHAP ACCOUN ee ee 39 3 6 Volume configuration cc ccc cece eeceeceeeeeeeeeseeteeeeeeaeeeaes 40 3
100. U MAC address 1500 1 LANL em me 192 1668 11 229 255 255 255 0 192 168 11 229 00 23 78 00 02 00 197 168 127 254 1560 2 LAN is z Ze 197 166 12 229 255 255 255 0 sl 00 13 78 00 02 01 Entity name iqn 2004 08 tw com qsan piz0c O00a00021 ISHS Luthenbeahon Abbildung E 7 7 W hlen Sie Trunking aus Falls LACP ben tigt wird sehen Sie sich bitte Abbildung E 12 an d System config SCSI Aggregation O Mult homed LANI Aggregation Trunking OLAce lt Back D Confirm F Abbildung E 8 8 Die Einstellungen befinden sich nun im Trunking Modus 100 System config SCSI ISNS Authenbeation e No Port Aggregation DHCP TP address Motmask Gateway MTU MAC address Trunki m 1500 i Jago ae e 192 168 11 229 255 253 253 0 192 168 11 229 8 00 13 78 00 02 00 Enbiby name ign 2004 08 Ce com gsanionl20c 000a002 1 NS e Auer abion e Abbildung E 9 9 Aktivieren Sie die Switch Trunking Funktion von Port 21 und 23 Untenste hend folgt ein Beispiel eines Switch Bitte sehen Sie sich bez glich des nachs ten Schrittes Abbildung E 14 an Ve Upenttanage Switch Administrator icra enter Internet n inna ele pet 192 eg 168 1 10 0252 Dell OpenManage Switch Administrator Support Help About Log Out 192 168 100 252 LAG Me mbership E Hore H System LAG Membership Sich Network Secur l Ports Address Tables GARP Park Spanning Tree 4 a 4 a 40 44 42 49 44 48 40 47 48 46 30 24
101. UDV 79 Volume config User data volume QCopy Target IP 192 168 10 187 Port 3260 Port Replicate lt lt Back D Next gt gt e Figure 4 5 2 Figure 4 5 2 input the target system data port IP address Volume config User data volume QCopy PXLELELLRTLLTLLIELTLLLELTELTLTLLLERT D Target LUN O 5GB EM Confirm a Figure 4 5 3 Figure 4 5 3 select the target UDV LUN the target UDV capacity must be equal or larger than the source UDV capacity 23 Sure to QCopy Replicate UDV04 1624 20 GB to 192 168 10 187 3260 LUN 3 20 GB Please dismount the disk in the host side first Cancel Figure 4 5 4 Figure 4 5 4 click OK after the target UDV is dismounted from host server 20 5 UDVO4 1624 03 28 16 24 44 O gt S SC gen Gur Dr Aug ban 0 e ve 116 e OCopy Node Name ign 2004 06 tw com gsan p120c 00032036e refinitiator 001 Attach e Snapshot e Create e Delete a d Figure 4 5 5 Figure 4 5 5 QCopy is copying and the completed percentage it 24 vi Tips QCopy supports 512B block size only for both source and target side gt 80 Caution Before executing QCopy it is better to dismount target file system for avoiding any inconsistent data IO The controller also send pop up message when user checks QCopy function lf QCopy access control is needed on the target system when user doesn t want any other system connecting
102. VG RO 100 Attach a Snapshot P Create Delete B Abbildung 4 4 1 1 Abbildung 4 4 1 1 Nr 1 ist eine RAID 0 UDV Legen Sie den Snapshot QSnap Platz mit 10 GB fest Sein Platz steht jetzt f r Snapshots QSnap zur Verf gung Nr 2 ist eine Snap UDV die am 14 02 um 17 13 35 erstellt wurde Snapshots QSnap unterliegen den folgenden Beschr nkungen 1 2 Die Mindest RAM Gr e f r die Ausf hrung der Funktion Snapshot QSnap be tr gt 512 MB Aus Performance Gr nden und f r zuk nftige Rollbacks speichert das System Snapshots QSnap unter fortlaufenden Namen Zum Beispiel Es wurden drei Snapshots QSnap angefertigt und snap1 erster snap2 und snap3 letzter genannt Wenn snap2 gel scht wird werden sowohl snap1 als auch snap2 ge l scht da snap mit snap2 verbunden ist 3 Aus Ressource Gr nden betr gt die maximale Anzahl an Snapshots QSnap 32 65 4 Wenn die gesamte Kapazitat fur Snapshots QSnap verbraucht ist sendet der Controller eine entsprechende Warnmeldung und neue Snapshots QSnap erset zen jeweils den altesten Snapshot 5 Ein Snap UDV kann nicht migriert werden bei der Migration von zugeh rigen VGs f llt das Snap UDV aus 6 Snap UDVs k nnen nicht erweitert werden Automatischer Snapshot Die Snapshot QSnap Kopien k nnen manuell oder zeitgesteuert z B st ndlich oder t glich erstellt werden Gehen Sie wie folgt vor 1 Wahlen Sie V
103. Verf gung Siehe das HBA Benutzerhandbuch des jeweiligen Herstellers Microsoft Linux und Mac stellen Software iSCSI Initiator Treiber zur Verf gung Nachfolgend finden Sie die zur Verf gung stehenden Links 1 Link zum Download des Microsoft iSCSI Software Initiators http www microsoft com downloads details aspx FamilvID 12cb3c1a 15d6 4585 b385 befd1319f825 amp DisplavLang en Siehe dazu auch Anhang D um Informationen Uber den Installationsvor gang des Microsoft iSCSI Initiators zu erhalten 2 Auch der Linux iSCSI Initiator ist verfugbar Fur unterschiedliche Kernels gibt es unterschiedliche iSCSI Treiber Fur die Software iSCSI lesen Sie bitte die Initiator Zertifizierungsliste im Anhang A nach Falls der Benutzer den letzten Linux iSCSI Initiator ben tigt besuchen Sie bitte Open iSCSI Projekte um aktuellere Informationen zu erhalten Linux iSCSI sfnet und Open iSCSI Projekte wurden am 11 April 2005 zusammengef hrt Open iSCSI Webseite http www open iscsi org Open iSCSI README hitp www open iscsi org docs README Fea tures http www open iscsi org cgi bin wiki pl Roadmap Unterst tzung Kernel http www open iscsi org cgi bin wiki pl Supported Kernels Google groups http groups google com group open iscsi threads gvc 2 http groups google com group open iscsi topics Open iSCSI Wiki http www open iscsi org cgi bin wiki pl 3 ATTO iSCSI Initiator ist f r Mac verf bgar Webseite http www attotech com
104. Volume config User data volume 2 Take one or more snapshots QSnap Please refer to section 4 4 1 for more detail 3 Click _ in Snapshot QSnap GB column to rollback the data which user can recover data to the time that snapshot QSnap is taken Rollback function has some constraints as described in the following 1 Minimum RAM size of enabling rollback function is 512MB 2 When doing rollback the original UDV cannot be accessed for a while At the same time the system connects original UDV and snap UDV and then starts rollback 3 During rollback data from snap UDV to original UDV the original UDV can be accessed and the data in it just like it finished rollback At the same time the other related snap UDV s can not be accessed 4 After rollback process finished the other related snap UDV s will be deleted and snapshot QSnap space will be set to 0 Caution Before executing rollback it is better to dismount file system for flushing data from cache to disks in OS first The controller also sends pop up message when user checks rollback function 4 5 QCopy remote replication GeViRAID QCopy service is to build a proprietary replication mechanism for created UDVs It will copy the logical user volume data exactly to the remote place The QCopy is built in service without any host based application for the data replication and it has easy configuration setup from web Uls The first QCopy ver
105. a E VG R6 663 Attach e Snapshot Create e Delete e Figure 3 6 4 1 Figure 3 6 4 1 Create a UDV named UDV 01 related to VG RO size is 30GB status is online write back high priority related to 1 LUN with cache volume 663MB 10GB snapshot QSnap space The other UDV is named UDV 02 initializing to 46 P100C does not support snapshot feature e UDV column description Number of this user data volume The button in below to the UDV No is More Information indication It shows the details of the User data volume Name of this user data volume The button in below to 46 the UDV Name is Rename function Size GB Total capacity of this user data volume The button in below to the size is Extend function The status of this user data volume Online gt user data volume is online Fail gt user data volume is failed WT gt Write Through WB gt Write Back RO gt Read Only The button in below to the status1 is Set read write mode function HI gt High priority MD gt MiD priority LO gt LOw priority The button in below to the status2 is Set Priority function Status 3 P gt user data volume is doing initializing R gt user data volume is doing rebuilding M gt user data volume is doing migration P gt user data volume is doing QCopy R Ratio of initializing or rebuil
106. address 1 192 168 201 10 162 IP address SNMP trap address 2 amp Scsi SNMP trap address 3 Login config Be public d E E Ee EST r el 1 1 2 Remote PC GeViScope Konfiguration Installieren Sie die Software SNMP Receiver Tool TrapReceiverV5 00 exe Download Internet oder ein SNMP Receiver Tool Ihrer Wahl E Setup Ze NETWORK COMPUTING R Welcome x Welcome to the Trap Receiver Setup Program This GkWare Program will install Trap Receiver on your computer To avoid problems please close all running Windows programs before proceeding Click Cancel to quit Setup Click Next to continue 88 Starten Sie das Programm TrapReceiver die Services Trap Receiver und den Windows Messenger Trap Receiver Alert Trap Receiver Service is not running Cancel Computer Manat Management a Eile Action View Window cp oer de Bas E DS amp kW ug Device t Manager Description O Sta Startup Type a ease oe errr T storage NEE Service Indexes contents and properties of files Disabled Ei Removable storage ity IPSEC Services Manages IP security policy and starts th Started Automatic Ex a analog td J ity Logical Disk Manager Detects and monitors new hard disk dri Started Automatic SS Fe Sy Logical Disk Manage Configures hard dek drives and volume Manual d ag e E 8 ofl md Control d i w ams Software Shada Manual lt a
107. ail Warning Fail to attach LUN to UDV lt name gt ee E rae Se Sac Tian lt number gt SCSI_ID lt number gt LUN lt number gt Started Finished wens lp ng Fail rebuilding mo ee ee Started Finished hill en Weeer Failed Gester Warning VG Degraded Warning VG lt name gt is under degraded mode Warming ve Degraded Warning UDV lt name gt is under degraded mode DR intafzaion Leschte ne man Initialization Initialization men aaa UDV lt name gt Warning VG Failed Error Fail to access VG lt name gt 89 Warning UDV Failed Error Fail to access UDV lt name gt Global CV Error Fail to adjust the size of the global cache Adjustment Failed Global Cache Info The global cache is OK ee en Er ee Failed Info UDV lt name gt has been renamed as lt name gt lt name gt ee a Spare Disks dedicated spare disk Disks UDV Read Only Info UDV lt name gt is a read only volume T ie Lem Policy lt name gt Policy lt name gt High priority UDV Info UDV lt name gt is set to high priority Info Mid Priority UDV Info UDV lt name gt is set to mid priority Low Priority UDV Info UDV lt name gt is set to low priority kee eee Error PD lt slot gt Iba lt gt length lt gt config read write error lt read write gt failed Lind Maine ees error Eege read write error length lt gt lt read write gt recoverable re e eee cel acta
108. al 2 ZU m m Empty Free 603 MB Create e Delete e Figure 3 6 7 9 1 Select Volume config Cache volume 2 If there is no free space for creating a new dedicated cache volume cut down the global cache size first by clicking the button in the size column After resized click confirm 7 to return to cache volume page 3 Click create _ to enter the setup page 56 4 Fill in the size and click a 5 Done A new dedicated cache volume has been set S Tips The minimum size of global cache volume is 40MB The N minimum size of dedicated cache volume is 20MB Step 2 Create VG Volume Group Please refer to Step 1 of Example 1 to create VG Step 3 Create UDV User Data Volume Please refer to Step 2 of Example 1 to create UDV To create a data user volume with dedicated cache volume please follow the below procedures Name UDY Ra 2 G name WO CH No Dedicated 20 MB Capacity GB S Stripe height KB GA sl Block size B 512 E Read Write write through cache write back cache Priority High priority Middle priority Low priority lt lt Back e Confirm m Figure 3 6 7 10 1 Select Volume config User data volume gt Click D Create DN e 3 Input a UDV name choose a VG Name select Dedicated cache which is created at Step 1 and input the size for the UDV decide the stripe height block size read write mode a
109. andardm iges Gateway 192 168 201 254 3 8 4 Konfiguration Import amp Export Die Funktion Config Import amp Export erm glicht dem Benutzer die konfigurierbaren Systemwerte zu speichern Export Funktion und alle Konfigurationswerte anzuwenden Import Funktion F r die Konfigurationseinstellungen des Volume stehen die Werte in der Export Funktion aber nicht in der Import Funktion zur Verf gung Das dient dazu Konflikte zwischen zwei Controllern und das L schen von Daten zu vermeiden Das hei t wenn auf der Festplatte eines Controllers bereits n tzliche Daten vorhanden sind der Benutzer dies eventuell aber vergisst und die Import Funktion verwendet Wenn die Einstellungen des Volume ebenfalls importiert wurden werden die aktuellen Daten des Benutzers gel scht Iin rt Eknert De E ene iG Import file Import Logical unit only Export Contirm A Abbildung 3 8 4 1 1 Import Import alle Systemkonfigurationen au er die Volume Konfiguration Import Logical unit only Importiert keine System und Volume Konfigurationen nur LUN Konfigurationen 3 Export Exportiert alle Konfigurationen in eine Datei 57 Achtung Die Import Funktion importiert alle Systemkonfigurationen au er der Volume Konfiguration Die aktuellen Konfigurationen werden ersetzt 3 8 5 Shutdown Wenn Sie die Shutdown Funktion w hlen werden der REBOOT und der SHUT DOWN Schalter angezeigt Bevor Sie das GeViRAID Il herunter
110. are is already installed on your computer Name Status Ba bernehmen Selektieren Sie Local adapter Microsoft iSCSI Initiator Source IP 192 168 1 10 IP Adresse Netzwerkkarte Target Portal 192 168 1 1 P Adresse GeViRAID I Select the Local adapter Microsoft iSCSI Initiator Source IP 192 168 1 10 IP Adresse network card Target Portal 192 168 1 1 P address GeViRAID Il kornet Settings General PSec Connect by using Ze Local adapter Microsoft iSCSI Initiator SourceIP 1 192 168 1 10 Target Portal BEIER y e CRC 7 Checksum Data digest Header digest CHAP logon information CHAP helps ensure data secunty by providing authentication between a target and an initiator trying to establish a connection To use it specify the same target CHAP secret that was configured on the target for this initiator User name ign 1991 05 com microsoft oem 4raidah1 7s3 Target secret Perform mutual authentication To use mutual CHAP specify an initiator secret on the Initiator Settings page and configure that secret on the targe OK Abbrechen bernehmen Klicken Sie auf OK Der Status lautet Connected Click OK The status would be Connected r Eigenschaften von iSCSI Initiator devices for that target Targets Name General Discovery Targets Persistent Targets Bound Volume
111. art Nach erfolgreicher Anmeldung stehen Ihnen alle Funktionen auf der linken Seite zur Verf gung Quick install System config SCSI contig Volume config Enciosure management Mamtenance Logout Abbildung 3 2 4 In der rechten oberen Ecke befinden sich sechs Symbole f r Backplane L sungen und drei f r Cabling L sungen Abbildung 3 2 2 19 RAID leuchtet Gr n bedeutet RAID arbeitet ordnungsgem f 3 Rot be 1 deutet eine Fehlfunktion bei RAID 2 18 Temperatur leuchtet Gr n bedeutet Normaltemperatur Rot bedeutet abnormale Temperatur 3 Spannung leuchtet Gr n bedeutet normale Spannung Rot bedeutet abnormale Spannung 4 D UPS leuchtet Gr n bedeutet Normalstatus Rot bedeutet abnormalen UPS Status 5 Bel ftung leuchtet Gr n bedeutet ordnungsgem e Funktion des Ge blases Rot bedeutet abnormalen Bel ftungszustand Nur f r Backplane L sung GEVIRAID 2 Energie leuchtet Gr n bedeutet normalen Energiestatus Rot bedeutet abnormalen Energiestatus Nur f r Backplane L sung GEVIRAID 2 3 3 Quick install Mit der Funktion Quick Install k nnen Sie ganz einfach ein Volume erstellen Abh n gig davon wie viele Physical Disks oder wie viel Reservespeicher auf erstellten VG vorhanden sind errechnet das System den maximalen Speicherplatz auf den RAID Le vels 0 1 3 5 6 Die Funktion Quick Install belegt den gesamten Speicherplatz eines VGs f r ein UDV somit ist
112. as cache User can divide the cache for one UDV or sharing among all UDVs Each UDV will be associated with one CV for data transaction Each CV could be assigned different cache memory size Logical Unit Number A logical unit number LUN is an unique identifier used on a iSCSI connection which enables it to differentiate among separate devices each of which is a logical unit RAID width RAID width copy and row are used to describe one VG RAID copy E g RAID row RAID cell in One 4 disk RAID O volume RAID width 4 RAID one row copy 1 RAID row 1 One 3 way mirroring volume RAID width 1 RAID copy 3 RAID row 1 One RAID 10 volume over 3 4 disk RAID 1 volume RAID width 1 RAID copy 4 RAID row 3 Write Through cache write policy A caching technique in which the completion of a write request is not signaled until data is safely stored on non volatile media Each data is synchronized in both data cache and the accessed physical disks Write Back cache write policy A caching technique in which the completion of a write request is signaled as soon as the data is in cache and actual writing to non volatile media occurs at a later time It soeeds up system write performance but needs to bear the risk where data may be inconsistent between data cache and the physical disks in one short time interval Set the volume to be Read Only Dedicated Spare disks The spare disks are only used by one specific VG Ot
113. ate Delete Abbildung H 5 6 Setup capacity stripe height and block size for UDV Volume config User data volume Create Mame ICE VG name vco CY Ao Global i 136 MB Capacity GB 3793 I Stripe height KB Black size Bi Read Write C write through cache F write back cache Priority IO High priority wre oraris Low priority ee Back a Conhrm a Abbildung Hp Tips Mit einem 64bit OS kann der Nutzer die Blockgr e auf je den verf gbaren Wert setzen Mit einem 32bit OS muss der Nutzer die Blockgr e auf Werte gr er 512B einstellen Zur Erinnerung wird ein Popup eingeblendet wenn die UDV Gr e ber 2TB liegt 124 Microsoft Internet Explorer DD LBA 64 support Choos OK df usmg CS such ae Windows 64 bit Windows Server 2003 SPL Linux komal 2 6 x FreeBSD 5 2 1 or letter Choose Cancel It wall change the sector age to 4K Tha ta an i up io 16 TE This volame can not be Dyrare Disk Abbildung H 7 w hlen Sie OK f r 64 Bit OS w hlen Sie Cancel f r 32 Bit OS dieser Schritt ndert die Blockgr e automatisch in 4 K 7 Ein 2 793 TB UDV wird erstellt Volume config User data volume Arr ach 5 Crozate a Delete i Wo Name Size Status 1 2 a R em sun S 68 Du b mame GO 1 VOYVOL 2793 Online DN we FP Hi G 2 m Attach e Craste DSS a Abbildung H 8 ein 2793 G UDV wird erstellt 8 be
114. aten zugreifen k n nen Der Microsoft iSCSI Initiator unterst tzt die Multi Path Funktion Bitte folgen Sie den Schritten um das MPIO Feature zu verwenden d 2 3 6 Le Ein Host mit dualen LAN Ports verbindet Kabel mit dem GEUTERBRUCK GeViRAID II Controller Erstellen Sie eine VG ein UDV verbinden Sie diese UDV mit dem Host Beim Installieren von Microsoft iSCSI Initiator installieren Sie bitte auch gleichzeitig den MPIO Treiber Loggen Sie sich in das Ziel bei jedem Port getrennt ein Beim Einloggen in das Ziel aktivieren Sie Enable multi path Weitere Hinweise finden Sie in Anhang D Schritt 6 Der MPIO Modus kann folgenderma en ausgew hlt werden Targets gt Details gt Devices gt Advanced F hren Sie einen Rescan der Disk durch Es wird eine Disk vorhanden sein die den MPIO ausf hrt Detaillierte Schritte f r das Setup finden Sie in Anhang F Setup Anweisungen f r MPIO und MC S Die Schritte f r das MC S Setup sind denen des MPIO sehr hnlich Bitte lesen Sie f r weitere Informationen auch im Anhang F nach 11 Anhang A Certification list RAM P100C P120C RAM Spec 184pins DDR333 PC2700 Reg register or UB Unbufferred ECC or Non ECC from 64MB to 1GB 32 bit or 64 bit data bus width x8 or x16 devices 9 to 11 bits column address Vendor Md ATP AG64L72T8SQC4S 512MB DDR 400 ECC with Sam sung ATP sOC AG28L64T8SHC4S 1GB DDR 400 with Samsung 7 e le 1GB
115. bebe oe Wester speci arm leld fecal on ihe mi ende Bade n GOR ue eee BAT ie feta et Abbildung F 27 12 Nachdem die Verbindung hergestellt wurde klicken Sie auf Details dann in der Registerkarte Session auf Connections Abbildung F 28 13 Wahlen Sie f r Load Balance Policy Round Robin aus 120 SO GOTITeCHOnG Abbildung F 29 14 Klicken Sie auf Add um das Quellenportal f r den ISCSI Data Port 2 192 168 12 229 hinzuzuf gen LEE UE Gomec UL The round robin policy attempt fo evenly distribute incoming requests to all processing paths Abbildung F 30 121 Abbildung F 31 15 Wahlen Sie Local Adapter Source IP und Target Portal als iSCSI Data Port 2 192 168 12 229 aus Klicken Sie dann auf OK Advanced Set INCH aT ein erom murta ati tenets ito r ii SEHE eae a ALTER PSO Io usa maus LAAT spol enmia Secret on tres trator eme Bade ar iGoryiQuie tel Ge etry rede gob Abbildung F 32 16 Die MC S Einstellung ist abgeschlossen 122 H Installationsschritte fur gro e Volumen TB Einf hrung GEVIRAID Controller k nnen gro e Volumen gt 2 TB aller Produktlinien unterst tzen Wenn Controller an einen 64 Bit OS Installed Host Server angeschlossen werden ist der Host Server f r gro e Volumen von 64 Bit Adressen geeignet Wenn dagegen der Host Server mit 32 Bit OS installiert wird muss der Benutzer die
116. build starts The new disk will be a spare disk to the original VG automatically a If the new added disk is not clean with other GeVIRAID VG information it would be marked as RS reserved and the system will not start auto rebuild b If this disk is not belonging to any existing VG it would be FR Free disk and the system will start Auto Rebuild function c if user only removes the failed disk and plugs the same failed disk in the same slot again the auto rebuild will start by this case But rebuilding in the same failed disk may impact customer data later from the unstable disk status GeViRAID suggests all customers not to rebuild in the same failed disk for better data protection 2 When there is enough global spare disk s or dedicated spare disk s for the degraded array The controller starts Auto Rebuild immediately And in RAID 6 if there is another disk failure happening during the time of rebuilding the controller will starts the above Auto Rebuild scenario as well And the Auto Rebuild feature only works at RUNTIME It will not work the downtime Thus it will not conflict with the Roaming function In degraded mode the status of VG is DG 69 When rebuilding the status of PD VG UDV is R and R in UDV will display the ratio in percentage After complete rebuilding R and DG will disappear VG will become complete one Tips The list box doesn t exist if there is no V
117. ck Advanced bo select specific settings for the discovery gassion to the rot TP address or DNS mame E 153 11 229 x Advanc l Abbildung D 2 4 Klicken Sie auf OK Bitte sehen Sie sich Abbildung D 3 5 an 94 Abbildung D 3 5 Klicken Sie auf Targets Bitte sehen Sie sich Abbildung D A an iSCSI Inthebor Properties Abbildung D 4 6 Klicken Sie auf Log On Sehen Sie sich bitte Abbildung D 5 an Bei der Verwendung von MPIO aktivieren Sie Enable multi path 95 Loo On to Target ENEE ERR target Abbildung D 3 7 Klicken Sie auf Advance falls die CHAP Information gebraucht wird Bit te sehen Sie sich Abbildung D 6 an Advanced Settings D e BE Gr b ie t SR A9 Bet Tape en Ur DG se e sl At Ji a Kaz GR It ae e Kaes ett r Ee i al WI ups ke She SE me Sr te 2 oe ate Pe EI i p Oir Jeer name z7 el In a Vie je u F A i i HR Te ee aT an oP menor SUE Secret at E Catam mia authertiatan i fai dal aa Ui e pl Ski Ze r Ffi l D A stell Ri EK Cl r Mk Le GE Hiili Bh ripen Ceased EE ee R Ha F i H el By Been et eet Hea of al 204 Ehl eer RTS eur Abbildung D 8 Klicken Sie auf OK Der Status lautet Connected Bitte sehen Sie sich Abbildung D 7 an 9 Fertig nun kann die Verbindung zu einer iSCSI Disk hergestellt werden 96 Abbildung D 7 Beim folgenden Ablauf geht
118. d a GeViRAID proprietary replication mechanism for created UDVs It will copy the logical user volume data exactly to the remote place The QCopy is built in service without any host based application for the data replication and it has easy configuration setup from GeViRAID management Uls GeViRAID RAID controller is the most cost effective disk array controller with completely integrated high performance and data protection capabilities which meet or exceed the highest industry standards and the best data solution for small medium business SMB users Caution Snapshot QSnap rollback features need 512MB RAM or more Please refer to RAM certification list in Appendix A for more detail 1 2 Terminology The document uses the following terms RAID is the abbreviation of Redundant Array of Independent Disks There are different RAID levels with different degree of the data protection data availability performance to host environment The Physical Disk belongs to the member disk of one specific volume group VG Volume Group A collection of removable media One VG consists of a set of UDVs and owns one RAID level attribute User Data Volume Each VG could be divided into several UDVs The UDVs from one VG share the same RAID level but may have different volume capacity Cache Volume GeViRAID uses the on board memory as cache All RAM except for the part which is occupied by the controller can be used
119. d drives RAID 30 Striping over the member RAID 3 volumes RAID 30 needs at least six hard drives RAID 50 Striping over the member RAID 5 volumes RAID 50 needs at least six hard drives RAID 60 Striping over the member RAID 6 volumes RAID 60 needs at least eight hard drives JBOD The abbreviation of Just a Bunch Of Disks JBOD needs at least one hard drive 10 1 4 Views and controls 1 4 1 Frontview GeViRAID GEUTEBRUCK GER PELC E PED GG Free oe it EMERE EE E OOOOod BESSER RI es es Pe TERE ENE O ENEE cot E e L G EISE CL GOGOE UOUO00 a en SE EE CREE LJ E LJ LI LJ L E LI L L L L E E LJ LJ 1 Central locking system 2 LCD status display 3 Control keys 4 LED for Host access 5 Power LED 6 LCM modules Hotplug 1 4 2 Rear view Fan modules Hot Plug ON OFF Serial interface RS 232 Com1 Sub D Redundant power supply units Security alarm relay Securion Interface Web GUI Port Ethernet 10 100 1000 Base T RJ45 ISCSI Host Ports Ethernet 10 100 1000Base T RJ45 SAS interface JBOD Extension CON DOOR WD NO 11 Chapter 2 Getting started 2 1 Before starting Before starting prepare the following items 1 Check the Certification list in Appendix A to confirm the hardware setting is fully supported 2 Read the latest release notes before upgrading Release notes accompany with release firmware 3 A server with a N
120. de der fr heren Firmware sp ter durchf hren m chten exportieren Sie zun chst Ihre System konfigurationen Klicken Sie auf Cancel um die Systemkonfigurationen zuerst zu ex portieren dann klicken Sie auf OK um das Upgrade der Firmware zu starten Browse the firmware to upgrade Browse Export config Confirm H 2 Uperade system now If you want to downgrade to the previous FW later Please export your system config first Cancel Abbildung 3 8 1 2 W hrend des Upgrades erhalten Sie eine Fortschrittsanzeige Nach dem das Up grade erfolgreich durchgef hrt wurde muss das GeViRAID II manuell neu gestartet werden Tips Bitte wenden Sie sich an info geutebrueck com f r die aktuellste Firmware 56 3 8 2 Info Durch die Auswahl der Funktion Info werden alle Systeminformationen einschlie lich Version der Firmware CPU Typ installierter Systemspeicher und Seriennummer der Controller angezeigt 3 8 3 Reset to default Die Funktion Reset to Default erm glicht es dem Benutzer den Controller auf die Werkseinstellung zur ckzusetzen Sure to reset to factory default Confirm e Abbildung 3 8 3 1 Das R cksetzen auf die Werkseinstellung setzt auch das Passwort zur ck n mlich auf start Es wird auch die IP Adresse auf die standardm ige DHCP Einstellung zur ck gesetzt Standardm ige IP Adresse 192 168 1 1 DHCP Standardm ige Subnet Mask 255 255 255 0 St
121. ding RAID The RAID levels that user data volume is using LUN Number of LUN s that data volume is attaching Snapshot The user data volume size that used for snapshot QSnap GB QSnap The button next to the snapshot QSnap is Resize function to decide the snapshot QSnap space The button next to the resize function is Auto snapshot QSnap function to setup the frequency of taking snapshots QSnap The number means Free snapshot QSnap space Total snapshot QSnap space If the snapshot QSnap UDV has been created this column will be the creation time 47 QCopy Remote replication function VGname The VG name of the user data volume CV MB The cache volume of the user data volume e UDV operations description Attach Attach to a LUN Snapshot Choose a UDV to execute snapshot QSnap Create Create a user data volume function Delete Delete a user data volume function 3 6 5 Cache volume Enter Cache volume function to view the status of cache volume The global cache volume is a default cache volume which is created after power on automatically and cannot be deleted The size of global cache is based on the RAM size It is total memory size minus the system usage Create e Delete e IT No Size UDY name 1 653 u 8 Global Free 0 MB Create e Delete e Figure 3 6 5 1 e CV column description Number of the Cache volume The button next to the CV
122. e Number i eee Microsoft iSCSI Software Initiator Release v2 05 System Requirements 1 Windows XP Professional with SP2 2 Windows 2000 Server with SP4 3 Windows Server 2003 with SP1 4 Windows Server 2003 R2 The iSCSI Initiators are different for different Linux Ker nels For Red Hat Enterprise Linux 3 Kernel 2 4 install linux iscsi 3 6 3 tar For Red Hat Enterprise Linux 4 Kernel 2 6 use the build in iSCSI initiator iscsi initiator utils 4 0 3 0 4 in kernel 2 6 9 For Red Hat Enterprise Linux 5 Kernel 2 6 use the build in iSCSI initiator iscsi initiator utils 6 2 0 695 0 7 e15 in kernel 2 6 18 ATTO XTEND 2 0x SAN Mac iSCSI Initiator GlobalSAN iSCSI Initiator v3 0 System Requirements 1 Mac OS X v10 3 5 or later For ATTO initiator it is not free Please contact your local distributor for ATTO initiator iSCSI HBA card Vendor Mdl ________ BE EENEG Adaptec ASC 7211C PCI X Gigabit 1 port TCP IP offload ISCSI offload 13 HP NC380T PCI Express Gigabit 2 ports TCP IP offload ISCSI offload wall cp PCI X Gigabit 1 port TCP IP offload iSCSI offload ben em PCI X Gigabit 2 ports TCP IP offload ISCSI offload For detailed setup steps of Qlogic QLA4010C please refer to Appendix G QLogic QLA4010C setup instructions NIC Vendor Model a RS D Link DGE 530T PCI Gigabit 1 port HP NC7170 PCI X Gigabit 2 ports HP NC360T PCI Exp
123. e a UDV by using the RAID 5 VG Volume config User data volume Attach e Snapshot e Create e Delete e Size 7 R Snapshot VG CW d No Name GB Status 1 A 3 de RAID et UN CB name MB i RS 10 f H wae Bur 0 00 0 00 Online C e k men a a BI 14 RAIDS 0 gt R5 100 Attach e Snapshot Create e Delete m Figure E 3 3 Run Microsoft iSCSI initiator 2 03 and check the Initiator Node Name 97 iSCSI Initiator Properties ply Figure E 4 4 Attaching LUN to R5 UDV Input the Initiator Node Name in the Host field Volume config Logical unit Attach UDV RS 1068 EI Host iqn 1991 05 com microsoft demo LUN f Permission ORead only Read write Figure E 5 5 Done please check the settings 98 Volume config Logical unit Attach a Detach a LI Host LUN Fermission UDV name Session C qn 1991 05 com microsoft demo 0 Read write R5 1 Session Attach a Detach H Figure Ep 6 Check iSCSI settings The IP address of iSCSI data port 1 is 192 168 11 229 Using port 1 as Trunking or LACP Click the blue square in Aggregation field to set Trunking or LACH System config iSCSI NS e Authentication e No Port Aggregation DHCP IP address Netmask Gateway MTU MAC address no no 1500 i LANI 192 1658 11 229 Poo owe ono 192 168 11 229 00 13 78 00 02 00 no 192 168 12 254 1500 2 LAN e m 197 166 124 229 2595 2
124. e ein UDV werden alle dem UDV zugeordneten LUNs automatisch getrennt Schritt 8 L schen einer VG Volume Group So gehen Sie vor 1 Wahlen Sie Volume Config Volume Group 2 Wahlen Sie durch Anklicken der Auswahlbox in der jeweiligen Reihe eine VG an Vergewissern Sie sich dass es kein UDV bei dieser VG gibt Ansonsten muss zuerst das UDV bei dieser VG gel scht werden 3 Klicken Sie auf Delete 7 In einem Popup Fenster wird eine Best ti gung angezeigt 4 Wahlen Sie OK 5 Fertig Die VG wurde nun gel scht wi Tips Das L schen von VG funktioniert nur wenn keine UDV mehr damit verbunden sind Andernfalls erhalten Sie eine Fehlermeldung Schritt 9 Freigeben der Global Spare Disk Um die Global Spare Disk freizugeben gehen Sie wie folgt vor 1 gehen Sie zu Volume Config Physical Disk 2 Wahlen Sie durch Anklicken des Auswahlmen s in der jeweiligen Reihe eine Global Spare Disk aus dann klicken Sie auf See SSS S um Disks freizugeben Schritt 10 Fertig alle Volumes wurden gel scht e Beispiel 2 In Beispiel 2 werden 2 UDV in einer VG erstellt Ein UDV nutzt das Global Cache Vo lume das andere ein dediziertes Cache Volume Zun chst sollte das dedizierte Ca che Volume erstellt werden es kann bei der Einrichtung des UDV genutzt werden Zum Schluss wird alles gel scht Jedes UDV ist einem bestimmten CV Cache Volume zur Ausf hrung von Daten Transaktionen zugeordn
125. e sure to connect the LAN cable The default IP setting is DHCP open the browser and enter http 192 168 10 50 Please check the DHCP address first on LCM Click any function at the first time it will pop up a dialog for authentication Login name admin Default password start After login you can choose the function blocks on the left side of window to do configuration Quick install System config iSCSI config Volume config Enclosure management Maintenance Logout Figure 3 2 1 There are six indicators at the top right corner for backplane solutions and cabling solutions have three indicators at the top right corner 290 Figure 3 2 2 E RAID light Green means RAID works well Red represents RAID 1 failure happening 2 Hemperature light Green is normal Red represents abnormal temperature 3 D light Green is normal Red represents abnormal voltage Status 4 D UPS light Green is normal Red represents abnormal UPS status D Fan light Green is normal Red represents abnormal fan status Only for backplane solution P120C P150C P200C 6 D Power light Green is normal Red represents abnormal power status Only for backplane solution P120C P150C P200C 3 3 Quick install It is easy to use Quick install function to create a volume Depend on how many physical disks or how many residual spaces on created VGs are free the system will calculate maximum
126. ectly controller will pop up warning messages Below is the detail of messages 1 Invalid VG ID Source VG is invalid 2 Degrade VG not allowed Source VG is degraded 3 Initializing rebuilding operation s going Source VG is initializing or rebuilding 72 4 Migration operation s going Source VG is already in migration 5 Invalid VG raidcell parameter Invalid configuration E g New VG s capacity lt Old VG s capacity New VG s stripe size lt Old VG s stripe size Or New VG s configuration Old VG s configuration 6 Invalid PD capacity New VG s minimum PD capacity lt Old VG s minimum PD capacity Caution VG Migration cannot be executed during rebuild or UDV extension 4 3 UDV Extension To extend UDV size please follow the procedures 1 Select Volume config User data volume Decide which UDV to be extended click the button in the Size column next the number 3 Change the size The size must be larger than the original and then click confirm 7 to start extension 4 Extension starts If UDV needs initialization it will display an P in Status 3 and complete percentage of initialization in R Volume config User data volume Extend Size 10 Free 71 GB lt lt Back e Confirm e Figure 4 3 1 Volume config User data volume Attach gt Snapshot Create gt Delete e Size tf R Snapshot VG CW d No Name GB Status 1 A 3 Se
127. ehlerhaften Betrieb oder das L schen von Daten zu verhindern Falls Daten wiederher gestellt werden m ssen k nnen die gleichen Schritte ausgef hrt werden wie bei einer Replikation Der Benutzer muss lediglich den Aufbau von QCopy vom Zielsystem r ckw rts durchf hren Die Funktion QCopy wird nur vom GEVIRAID II unterst tzt 68 20 VI EMOL LP AA Inu D378 16 24 44 2 SS mao ov RAID 6 aa S e OCapy Mode Name m Com qsan p120c 000a2036e refinitiator O04 Attach Snapshot Create D Delete a Abbildung 4 5 1 Abbildung 4 5 1 QCopy Setup f r ausgew hlten Snapshot QSnap UDV volume config User data volume OCopy Port Replicate Ka ce Rack a Hari gt gt 5 Abbildung 4 5 2 Abbildung 4 5 2 Eingabe der Data Port IP Addresse f r das Zielsystem Volume config User data volume OCopy Target LUA Abbildung 4 5 3 Abbildung 4 5 3 Auswahl der Ziel UDV LUN die Speicherkapazitat des Ziel UDV muss so gro oder gr er als die des Quellen UDV sein A Sure to OCopy 1 Replicate UDVO4 1624 20 GB to 192 168 10 187 3260 LUN 3 20 GB Plaase dismount the disk in the host side first Abbildung 4 5 4 Abbildung 4 5 4 Nach dem Dismount des Ziel UDV vom Host Server klicken Sie auf OK 20 8 UDVO4 1624 Ehe 03 28 16 24 44 u 5 nn Dm GP 24 RAIDS 0 Se VG6 116 zu Copy Mode Name jop 2004 08 tw com gsan p120c 0003203 amp e refintistor 001 Attach D Snapshot e Create Dele
128. em Pieper u Guests eg age een een 16 2 4 3 LED EE 17 Kapitel3 Bedienung der Web GU 22z22222 18 3 1 GUI Struktur Men baum cee cecc eee eeeeeeeeeeeeeeees 18 3 2 Beete 19 3 3 Quick INS Allen nennen nee een 20 3 4 System Konfiguration een nne nennen 22 3 4 1 System NaMe een ee re en 22 3 4 2 IP ee ee 22 3 4 3 EE Eege 23 3 4 4 Login KONIOULAUON nenne een ee 23 3 4 5 PASS WON ee ee 24 3 4 6 DAN 2 see ee 24 3 4 7 UE 24 3 4 8 IN en ee 25 3 4 9 Messenger 26 3 4 10 System log Server an ee ee 26 3 4 11 gl Le WEN 27 3 5 ISCSI KONFIQUIATION cccccecssesesecsrseressccersuesseseneeuss 28 3 5 1 ENUY DODO E 28 3 5 2 NIC een een een 28 353 Kli 31 3 5 4 EE geed 32 3 9 5 GHAPGECOUN EEN 33 3 6 Volume konfguraton een ennnnn nennen 33 3 6 1 Volume Relationsdiagramm cccccceccseceseeeseeeeeeeaeeeseeeseeeaees 34 3 6 2 Physical RTE 34 3 6 3 Volume Ee e EE 37 3 6 4 User Data VolUMe E 39 3 6 5 BAcNE VOTE E 41 3 6 6 Logical Unit NUMBER en 42 3 6 7 See EE 43 3 Geh use Management nn nennen nenne 52 3 7 1 SES le le ee 52 3 1 2 Hardware Monitor een 53 3 7 3 Unterst tzung der S M A R T Funktion f r Festplatten 54 3 7 4 HE 54 3 8 SYSIENIWALLUNG ee ee er nioemteiedenseer 55 3 8 1 Bieiele ie 56 3 8 2 Inte GE 57 3 8 3 Reset auf RE 57 3 8 4 Konfiguration Import amp Export essen 57 3 8 5 SAGO W EE 58 3 9 LOGOUT eer E 58 Kapitel 4 Erweiterte Benutzung 22u022020020 59 4 1 Kill
129. en L schen Weitere Informa Volume tionen Umbenennen Erweitern Lese Schreibmodus ein stellen Priorit t einstellen Snapshotgr e ndern Automa tischer Snapshot Cache volume gt Erstellen L schen Weitere Informationen Gr e ndern Logical unit gt Anh ngen l sen Enclosure management SES config gt Aktivieren Deaktivieren Hardware gt automatisches Herunterfahren monitor SMART gt Nur f r SATA Disks UPS gt UPS Typ Batteriestand f r Shutdown Verz gerung f r Shutdown UPS f r Shutdown Maintenance Upgrade gt Firmware f r Upgrade durchsuchen Konfiguration exportie ren Info gt Systeminformationen 18 Reset to default gt M chten Sie die Herstellereinstellungen wieder herstellen Config import gt Import Export Datei importieren amp export Shutdown gt Neu starten Herunterfahren M chten Sie sich wirklich abmelden 3 2 Login GeViRAID II Controller unterst tzen grafische Benutzeroberflachen Graphic User Inter face GUI f r die Systemsteuerung Vergewissern Sie sich dass das LAN Kabel ange schlossen ist Die Standard IP Einstellung ist DHCP bitte ffnen Sie den Browser und geben Sie folgenden Link ein http 192 168 201 150 berpr fen Sie die DHCP Adresse zuerst auf dem LCM Klicken Sie zun chst auf eine beliebige Funktion es erscheint ein Dialogfenster f r die Au thentifizierung als Popup Login Name admin Default password st
130. en Weitere Details finden Sie in Ihrem SCSI HBA Handbuch Bei der P Serie iSCSI muss der Benutzer zun chst den Software iSCSI Initiator oder iSCSI HBA einrichten 2 Im Folgenden finden Sie die Konfiguration f r Windows Server 2003 R2 mit Microsoft iscsi Initiator Installieren Sie den neuesten Microsoft iscsi Initiator vom folgenden Link http Awww microsoft com downloads details aspx FamilyID 12cb3c1a 15d6 4585 b385 befd1319f825 amp DisplayLang de 126 CST Initiator Properties Geh T anget Pot tal Type the IP address or ONS name and socket number of the portal you General Discovey Target Paisistent Targets Bound Yolumes Dewice The CE protocol nes the following information to urigueiy want bo add Chick Advanced to select specific sethings for the discovery idertly his initiator ard authenticate begets session bo the portal Intiator Hode Name ign 1 997 D oun maceal dema OP address or DNS name Rz 166 11 zz Achancet To rename the infiatee node ckek Change Change _ Cancel be elitr dak lis lta Secu ite Seite Tunnel Mode ackheeses cick Tune i OK Cancel Apri Abbildung H 13 Abbildung H 13 F hren Sie den MS iSCSI Initiator aus gehen Sie zur Registerkarte Discovery f gen Sie das Target Portal iSCSI Daten hinzu CS Inikbator Properties d iSCSI Inatiabor Properti s Log ln to arget Gereral Discove Targets Peisistent Targets Sound Youmes
131. en ProduktNamen und Warenzeichen von GEUTEBRUCK sind entweder Warenzeichen Marken oder registrierte Warenzeichen Marken der GEUTEBR CK GmbH Microsoft Windows Windows NT Windows 2000 Windows XP MS DOS sind Warenzeichen oder eingetragene Warenzeichen der Microsoft Corporation Intel und Pentium sind eingetragene Warenzeichen der Intel Corporation Andere in diesem Handbuch erw hnte Produkt und FirmenNamen sind Warenzeichen Marken Ihrer jeweiligen Eigent mer Hinweis GEUTEBR CK GmbH haftet nicht f r Sch den die durch unsachgem e Ausf hrung oder durch Nichtbeachten der in diesem Handbuch beschriebenen Anweisungen entstehen Technische nderungen werden von GEUTEBR CK ohne vorherige Ank ndigung durchgef hrt GEUTEBRUCK haftet nicht f r Druckfehler in diesem Dokument F r Betrieb Wartung und Reparatur sind die allgemein g ltigen VDE Bestimmungen insbesondere VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 und VDE 0860 die Sicherheitsbestimmungen der rtlichen Stromversorgungsunternehmen sowie die speziellen innerbetrieblichen Richtlinien zu beachten Das Ger t darf nur in der seiner Bestimmung entsprechenden Funktion in Betrieb genommen werden Alle nicht mit dem Hersteller schriftlich vereinbarten nderungen des Ger ts oder nderungen in der Handhabung bewirken das Erl schen der Herstellerhaftung ber dieses Handbuch In diesem Handbuch werden die Handhabung Einstellungen Verfahren mechanische Arbeiten und das
132. en fur Ereignisprotokolle sind lediglich die Hinweise ERROR und WARNING System config Mail Mail from address mailman controller Mail to address 1 Send events 1 INFOT WARNING ERRORIY Mail to address 2 Send events 2 INFO WARNING M ERROR Mail to address 3 Send events 3 INFOT WARNING IY ERROR I SMTP relay E SMTP server Authentication None sl Account Password Confirm Send test mail C Abbildung 3 4 7 1 3 4 8 SNMP W hlen Sie SNMP wenn Sie eine Trap Benachrichtung via SNMP w nschen Sie haben die M glichkeit bis zu 3 SNMP Trap Adressen einzugeben Die Standardeinstel lung f r Community lautet public Benutzer k nnen die Ebene des Ereignisprotokolls w hlen Der einzige aktivierte SNMP Standardwert f r ein Ereignisprotokoll lautet INFO System config SNMP SNMP trap address 1 SNMP trap address 2 SNMP trap address 3 Community public Send events INFOM WaRNINGE ERROR Abbildung 3 4 8 1 25 Es gibt zahlreiche SNMP Tools Auf den folgenden Webseiten finden Sie weitere Infor mationen hierzu SNMP c http www snmpc com Net SNMP _hitp net snmp sourceforge net 3 4 9 Messenger In der Auswahl Messenger kann festgelegt werden dass als Warnung eine Popup Nachricht via Windows Messenger nicht MSN angezeigt wird Benutzer m ssen den Service Messenger unter Windows Start gt Control Panel gt Administrative Tools gt Services gt Me
133. er Festplatten und meldet wenn eine Festplatte sich den Toleranzgrenzen n hert Diese erweiterte Benachrichtung von m glichen Festplatten fehlern erm glicht es dem Benutzer ein Backup durchzuf hren oder die Festplatte rechtzeitig zu tauschen Diese Option ist nat rlich bei Weitem vorteilhafter als wenn eine Festplatte beim Schreiben von Daten oder beim Rebuild einer defekten Festplatte absturzt In jeder S M A R T Funktion werden die S M A R T Informationen f r jede Festplatte ange zeigt Die Zahl ohne Klammer stellt den aktuellen Wert dar die Zahl in Klammer den Grenzwert Die Grenzwerte k nnen je nach Festplattenhersteller variieren F r Details lesen Sie die Spezi fikationen des jeweiligen Herstellers Die S M A R T Information wird nur vom SATA Drive und nicht vom SAS Drive unterst tzt Auf dieser Webseite wird N A angezeigt Enclosure management 5 M A 8 T Reallocated sector Seek error Slot Readerror Spin up Spinup Calibration Temperature status rate timsae coumt rate re brtes retries E 1 20363 25363 253 0 2534157 253 223 a Goon d 100 16 107 24 100 5 100 67 100 60 1 ee 3 100 16 104 24 10015 100 57 TER 32 dee Gi Good r pen a map i Geod 5 100 16 102 24 10015 10067 10060 32 Luc 6 203 63 gt 53 63 25310 254157 253223 28 GER 7 94 16 90 24 100 5 100167 100 60 31 Bh amp 200 51 171 21 200 140 200 51 100651 100 51 30 em Abbildung 3 7 3 1 Im Men UPS habe
134. er Status Link f r einen Port nicht funktioniert Siehe Anhang E f r detaillierte Schritte hinsichtlich des Setups Trun king LACP Setup Anweisungen Achtung Beim GEVIRAID II muss jeder der iSCSI Data Ports in unter schiedlichen Subnets eingestellt werden Die anderen Modelle sind nicht solchen Einschr nkungen unterworfen 30 3 5 3 Node Single node Multi node Wahlen Sie Node um den Target Namen f r den iSCSI Initiator anzusehen GEVI RAID Il unterst tzt single node Der Node Name von GEVIRAID Il existiert als Stan dardwert und kann nicht ge ndert werden Name Auth None iqn 2004 08 tw com gsan p150c 000383001 default target Abbildung 3 5 3 1 Abbildung 3 5 3 1 GEVIRAID Il single mode CHAP CHAP ist die Abk rzung f r Challenge Handshake Authorization Protocol CHAP ist eine sichere Methode zur Authentifizierung die mit point to point fur den User Login genutzt wird Sie ist eine Art Authentifizierung in welcher der Authentifizierungsser ver dem Client einen Key f r die Verschl sselung von Benutzernamen und Passwort schickt CHAP erm glicht den Versand von Benutzernamen und Passw rtern in verschl sselter sicherer Form Beim GEVIRAID II sollten sie die folgenden Schritte befolgen falls Sie die CHAP Authentifizierung nutzen m chten 1 Klicken Sie auf in der Spalte Auth 2 Wahlen Sie CHAP 3 Gehen Sie zu iSCSI Config CHAP Seite um ein Konto und ein Passwort anzulegen
135. ere are four buttons to control GeViRAID LCM LCD Control Module including A up v down ESC Escape and ENT Enter 15 After booting up the system the following screen shows management port IP and model name 192 168 201 150 GeViRAID Press ENT the LCM functions Alarm Mute Reset Shutdown Quick Install View IP Setting Change IP Config and Reset to Default will rotate by pressing 4 up and w down When there is WARNING or ERROR level of event happening the LCM shows the event log to give users more detail from front panel too The following table is function description Alarm Mute Mute alarm when error occurs Reset Shutdown Reset or shutdown controller Quick three steps to create a volume Please refer to section 3 3 for operation in web Ul View IP Setting Display current IP address subnet mask and gateway Change IP Set IP address subnet mask and gateway There are 2 Config selections DHCP Get IP address from DHCP server or set static IP Reset to Default Reset to default sets password to default start and set IP address to default as DHCP setting Default IP address 192 168 201 150 DHCP Default subnet mask 255 255 255 0 Default gateway 192 168 10 254 The following is LCM menu hierarchy GeViRAID Alarm Mute 4Yes Nov Technology Reset 4Yes Nov Ay Reset Shutdown Shutdown 4Yes Nov EEE RAID 0 Volume Si
136. ervices and Applications g Performance Logs and Alert 4 lt Disk 0 gen l Basic Windows i Bert m EI AAA 74 50 GB 13 53GB N 19 53 GE F 19 53 GB au Online Healthy Sy Bert Bi H F j ZPDisk 1 Basic 152 67 5B 152 97 GB Online Unallocated BB Unallocated RB Primary partition SS Extended partition SS Logical drive Co eee Figure G 9 H Installation Steps for Large Volume TB Introduction GeViRAID controllers are capable to support large volumes gt 2TB on all product lines When connecting controllers to 64bit OS installed host server the host server is inherently capable for large volumes from the 64bit address On the other side if the host server is installed with 32bit OS user has to change the block size to IKB 2KB or 4KB to support volumes up to 4TB 8TB or 16TB for the 32bit host server is not LBA Logical Block Addressing 64bit supported For detail installation steps please check below Step A configure your target 1 Goto Volume config Volume group create a VG 131 d Volume config Volume group Create m Delete e Total Free Li No Name GB EB PD UDY Status il BAe RAID dm Create e Delete e Figure Hi 2 Choose RAID level and disks Volume config Volume group Create Name sol RAID Level RAID 6 r RAID PD slot 910111213141516 Select PO d ee Back e fn Next gt gt e Figure H 3 Confirm VG settings Z Volume confi
137. es bereitstellen Die Rollback Funktion dient der einfachen Wiederherstel lung von Daten aus einem vorhergehenden Snapshot w hrend auf die bestehenden Daten weiter voll zugegriffen werden kann Der Zugang zu den Daten erfolgt wie blich einschlie lich Lesen und Schreiben ohne irgendeine Auswirkung f r den Benutzer Durch die on the box Technik muss auf dem Host keine zus tzliche Software oder Agenten installiert werden Snapshots werden auf und durch das GeViRAID II durchge f hrt so dass die Host CPU dadurch nicht belastet wird Je nach Ein Einstellung k nnen Snapshots manuell oder zeitgesteuert t glich oder st ndlich erstellt werden Der QCopy Service dient dazu einen gesch tzen GeViRAID Replikationsmechanismus f r von GeViRAID erstellte UDVs zu implementieren Durch diese Funktion wird das logische User Data Volume genau an den Remote Ort kopiert Das QCopy ist ein intergriertes Service ohne jegliche Host basierte Applikation f r den Datenabgleich und zeichnet sich durch einfache Konfigurationsm glichkeiten ber GeViRAID Management Uls aus Das GeViRAID Il ist eins der kosteng nstigsten Disk Arrays mit sehr leistungsf hi gen integrierten Funktionen f r Hochverf gbarkeit und Sicherheit der Daten die den h chsten Standards und Forderungen der Industrie entspricht und damit eine der bes ten L sungen f r kleine und mittlere Unternehmen darstellt Achtung Die Funktionen Snapshot QSnap Rollback ben tigen mindesten
138. es um das Ausloggen des iSCSI Device 1 Klicken Sie auf Details Bitte sehen Sie sich Abbildung D 8 an larget Properties Abbildung D 8 2 Markieren Sie den zu l schenden Identifier 3 Klicken Sie Log Off an 4 Fertig das iSCSI Device wurde erfolgreich ausgeloggt 97 F Setup Anweisungen fur Trunking LACP Es folgt schrittweise das Setup fur Trunking und LACP Es gibt zwei Szenarien fur Trunking LACP Bitte sehen Sie sich Abbildung E 1 an Trunking Lac D nd LE Feng TSAN P sos 1 Dual ports with Tronking LACP 2 Dual ports with Trunking LACP Via switch read or write in one With 2 hosts one read one write in UDY 2 UDVs at the same time Abbildung E 1 Netzwerk Diagramm des Trunking LACP Die Setup Anweisungen sind in den folgenden Abbildungen zu sehen 1 Erstellen Sie eine VG mit RAID 5 mithilfe von 3 HDDs Volume config Volume group otal Free Ti i CJ No Hamme Sp GB ZPO UDY Status LA 3 RAID 1 R3 Ce Onli RAID 5 E e 76 76 3 een t Create e Delete Abbildung E 2 2 Erstellen Sie ein UDV mithilfe des RAID 5 VG 98 Volume config User data volume Attach a Sap Sot Create Delete a i m Size E R ei Snapshot VG CN Cl Ma Name CB Status 1 d a RAID LUN CR nania ME o 10 7 0 00 0 00 R atin oo eee ess we m o un RAIDS 0 NN RS 100 Attach Snapshot a Creste a Delete m Abbildung E 3 3 Starten Sie Microsoft iSCSI Initiator 2 03 und
139. escription The position of hard drives The number of slot begins from left to right at the front side The button next to the number of slot is More Information indication It shows the details of the hard drive 42 wn O World Wide Name Size GB Capacity of hard drive Related volume group name The status of hard drive GOOD gt the hard drive is good DEFECT gt the hard drive has the bad blocks FAIL gt the hard drive cannot work in the respective volume RD gt RAID Disk This hard drive has been set to RAID FR gt FRee disk This hard drive is free for use DS gt Dedicated Spare This hard drive has been set to the dedicated spare of the VG GS gt Global Spare This hard drive has been set to a global spare of all VGs RS gt ReServe The hard drive contains the VG information but cannot be used It may be caused by an uncompleted VG set or hot plug of this disk in the running time In order to protect the data in the disk the status changes to reserve It can be reused after setting it to FR manually R gt Rebuild The hard drive is doing rebuilding M gt Migration The hard drive is doing migration 3 0G gt From SATA ATAPI standard if the disk can support ATAPI IDENTIFY PACKET DEVICE command and the speed can achieve Serial ATA Gen 2 signaling speed 3 0Gbps 1 5G gt From SATA ATAPI standard if the disk
140. et Die CV k nnen sich in der Gr e unterscheiden Wenn nicht anders angegeben nutzen UDV s das Global Cache Volume Zur Erh hung 47 der Performance kann f r jedes UDV ein dediziertes Cache Volume angelegt wer den Die Gesamtgr e des Cache h ngt von der Gr e des installierten RAM ab Um ein dediziertes Cache Volume einzurichten muss zun chst die Gr e des Global Cache Volume verringert werden Schritt 1 Erstellen eines dedizierten Cache Volume Create e Delete o E No Size UDV name 1 40 E e e Global 2 20 E 2 Empty Free 603 MB Abbildung 3 6 7 9 1 Gehen Sie zu Volume Config Cache Volume 2 Wenn kein freier Platz fur die Erstellung eines neuen dedizierten Cache Volume verf gbar ist verringern Sie zuerst die Gr e des Global Cache indem Sie die Taste in der Gr enspalte anklicken Nach der Gr en nderung klicken Sie auf confirm e um zur Seite Cache Volume zur ckzukehren 3 Klicken Sie auf reale Dn um zur Seite mit den Einstellungen zu ge langen 4 Geben Sie die Gr e ein und klicken Sie auf Te 1 Fertig ein neues dediziertes Cache Volume wurde eingerichtet Tips Die Mindestgr e f r ein Global Cache Volume betr gt 40MB f r ein dediziertes Cache Volume 20MB Die Einrichtung eines UDV ist in Beispiel 1 in Schritt 2 beschrieben Um ein UDV mit einem dedizierten Cache Volume zu erstellen f hren Sie die nachfolgend be schriebenen Schritte aus
141. et ne Abbildung F 13 13 Aktivieren Sie die Auswahlbox Enable multi path Klicken Sie dann Advanced an 112 Abbildung F 14 14 Wahlen Sie als Target Portal den iSCSI Data Port 1 aus 192 168 11 229 Danach klicken Sie auf OK Bene F Adwand d Serhings el ER Er SET E EE bai fhe tbe BU ee a i HAR Repi arni Ue Ke UE EK Ang Ale alap hitzak USA lt ar lenken SH Ee TT BAU Lie et DTS Ser E fe r J I i Kai m Gel Rn a Te VEITH EST DET ee SEIT TR Abbildung F 15 15 Loggen Sie sich noch einmal bei Enable multi path ein 113 Tex Initiator Properties Abbildung F 16 16 Aktivieren Sie die Auswahlbox Enable multi path Klicken Sie dann auf Advanced Abbildung F 17 17 Wahlen Sie als Target Portal den iSCSI Data Port 2 aus 192 168 12 229 Danach klicken Sie auf OK 114 Advanced Settings IG aeg Dele SEO Tee WS Cl p pp le Lear er age FETTE 1 ree bk DN 5 A LES v L t DS T Beron motal authentizston Io usa Tue CHA specify eerahet Gr Secretion tise miad Setinge Ke i P 1 t wi 9 e Gap an aay Que lie sec Or Tee leo Del Abbildung F 18 18 Das iSCSI Device ist verbunden Klicken Sie auf Details ISS Initiator Properties Abbildung F 19 19 Klicken Sie auf die Registerkarte Device dann klicken Sie Advanced an 115
142. ets Persistent Targets Bound Volumes Devices Target Portals Address Port 192 168 1 1 3260 Default ISNS Servers Adapter Ta IP Add Default Remove Refresh Name Remove Refresh OK Abbrechen bernehmen Add Target Portal Type the IP address or DNS name and socket number of the portal you want to add Click Advanced to select specific settings For the discovery session to the portal IP address or DNS name Port 192 168 1 1 3260 Advanced cm Klicken Sie auf Targets Klicken Sie auf Log On Aktivieren Sie Automatically restore this connection when the systems boots Klicken Sie auf Advanced Click Targets Click Log On Enable Automatically restore this connection when the systems boots Click Advance Eigenschaften von iSCSI Initiator 5 F General Discovery Targets Persistent Targets Bound Volumes Devices Log On to Target Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and devices for that target Target name ign 2004 08 tw com qsan p120c 000a82068c default target Targets V Automatically restore this connection when the system boots Enable multi path A Only select this option if iSCSI multi path softw
143. fahren sollten Sie im mer zuerst das SHUTDOWN w hlen damit Daten die sich evtl noch im Cache des GeViRAID II befinden auf die Festplatten geschrieben werden Wenn nicht k nnen Daten verloren gehen Reboot m Shutdown Abbildung 3 7 6 1 3 9 Logout Aus Sicherheitsgr nden bietet das GeViRAID II die Logout Funktion um die Ma nagement Oberfl che vor unbefugtem Zugriff zu sch tzen Zum Re login geben Sie bit te Usernamen und Passwort ein 58 Kapitel 4 Erweiterte Operationen 4 1 Rebuild Wenn eine Disk der VG die als gesch tzter RAID Level gilt z B RAID 3 RAID 5 oder RAID 6 ausfallt ausgesteckt oder entfernt wird andert sich der VG Status in den Mo dus degraded Das System sucht bzw erkennt nun eine Spare Disk um die degra ded VG wieder neu einzubinden Diesen Vorgang nennt man Rebuild Als erstes erkennt es dedizierte Spare Disks als Rebuild Disks dann Global Spare Disks GeViRAID Controller unterst tzten die Funktion Auto Rebuild Wenn der RAID Level Diskausf lle erlaubt gegen die die VG gesch tzt ist z B RAID 3 RAID 5 RAID 6 usw startet der GEVIRAID Controller das Auto Rebuild wie im folgenden Szenario beschrieben Anhand des Beispiels RAID 6 1 Wenn es im System keine globale oder dedizierte Spare Disk gibt bleibt der GEVI RAID Controller im Modus degraded und wartet solange bis A eine Disk als Spare Disk zugewiesen wird oder B die ausgefallene Disk entfernt und d
144. folgt auf eigenes Risiko I gt gt PPP Technische Spezifikation GeViRAID 11 16 iSCSI ISCSI to S ATA RAID System oe 19 Rack 4HE gt Basisger t ohne Festplatten Festplattenanzahl max 16 x S ATA Il RAID Level 0 1 3 5 6 und 0 1 2fach 1000Base TX iSCSI RK Schnittstelle b Uberwachung der Betriebsdaten Konfiguration ber serielle Schnitt stelle oderWeb Browser Netzwerkbenachrichtigung im Fehlerfall Festplatten L fter und Netzteile Hot Swap f hig Zus tzliches Sicherheits Alarm Relais potentialfrei zur Meldung von St rungen aller Art Der Einsatz einer zus tzlichen Ethernetkarte mit einer Bandbreite von 1Gbps 1000Base TX ist im Host Computer erforderlich Zum Betrieb muss auf dem Host Computer die kostenlos erh ltliche Software Microsoft iSCSI Initiator installiert werden e Robustes Metallgeh use e berwachung der Festplatten Betriebstem e Unterst tzt RAID Level 0 1 3 5 6 30 peratur L fter und Netzteile 50 60 und 0 1 e Hot Swap von Festplatten L ftern und Netz e Bis zu 16 S ATA II Hot Swap Festplat teilen ten e Disk roaming Funktion e Netzwerkbenachrichtigung im Fehlerfall e Sicherheits Alarm Relais e Unterst tzung mehrerer RAID Arrays multiple RAID Technische Daten GeViRAID II 16 Host Schnittstelle 2fach 1000Base TX iSCSI Schnittstelle Anzahl Festplatten Max 16 S ATA oder S ATA II Cache Memory Bis zu 1024 MB ECC 512 MB installiert RAID Level 0 1 3 5 6 30 50 60 0 1
145. formation to uniquely want to add Click Advanced to select specific settings For the discovery identify this initiator and authenticate targets session to the portal Initiator Node Name op 1207 DE com microsoft dema IP address or DNS name Port 192 168 11 220 3260 Advanced Sg To rename the initiator node click Change Change Cancel To authenticate targets using CHAP click Secret to c e specify a CHAP secret secret To configure IPSec Tunnel Mode addresses click T Tunnel MIEL Henare Refresh Apply UK Cancel Apply Figure H 13 135 Figure H 13 Run MS iSCSI initiator go to Discovery tab add target portal iSCSI data iSCSI Initiator Properties General Discovery Targets Persistent Targets Bound Volumes Devices Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and devices for that target Automatically restore this connection when the system boots Targets Enable multi path D Only select this option if 15751 multi path software is already installed ign 2004 08 tw com gan pbUc O000000ed def Inactive on your computer Advanced Cancel Details Refresh Details Log On Refresh OF Cancel Apply OF Cancel Apply Figure H 14 Figure H 14 go to Targets tab click Refresh and then
146. g Volume group Create Confirm Create GOL RAID 6 RAID width SI RAID copy 1 RAID row RAID PD slot 9101112131415 16 xe Back e A Contirm e Figure H 3 A A RAID 6 VG is created d Volume config Volume group Create e Delete Total Free f No Name GE CB PD FUDY Status 1 2 3 RAID 1 Vol Online RAID 6 m ve 2793 2793 5 8 Create e Delete e Figure HA 5 Goto Volume config User data volume create a UDV 132 d Volume config User data volume Attach e Create e Delete 5 Size R YG cy E No Name cE Status Eiaa RAID SUN SEN MB Attach e in Create 5 Delete a Figure H 5 6 Setup capacity stripe height and block size for UDV Z Volume config User data volume Create Name UDO YG name Sp sl CH No Global 136 Me sl Capacity GB 2793 I Stripe height KB 54 gt Block size B 512 sl Read Write C Write thraugh cache write back cache Priority f High priority Middle priority Low priority lt Back e Contirm e Figure Hp Tips When the OS is 64bit user can set the block size to any available value If the OS is 32bit user must change the block size to larger values than 512B There will be a confirmation pop up when UDV size is over 2TB for reminding Microsoft Internet Explorer sl o LBA 64 support y Choose QE if uane O8 such as Windows 64 bits Windows Server 2003 SP1 Linux kernel 2 6 FreeBSD 5 2 1 or latter
147. ge Anwendung f r die Datenreplikation Au erdem verf gt es ber ein einfaches Konfigurations Setup f r Web Uls Die erste QCopy Version kann von einem Snapshot QSnap UDVs des Quel len Device auf das entfernte Ziel Device kopieren QCopy kann zwei Kopieraufgaben im System ausf hren die der Benutzer einstellen kann QCopy zu 2 Snapshot QSnap UDVs zum Kopieren zur gleichen Zeit Das Ziel Device muss Uber die gleiche oder eine gr ere Speicherkapazitat als das Quellen Device ver 67 f gen Die Kapazit t des Ziel UDVs verf gt ber dieselbe oder eine h here Kapazit t als das Quellen UDV Um eine Qcopy Aufgabe auszuf hren befolgen Sie bitte die unten angef hrten Schritte 1 Erstellen Sie einen Snapshot QSnap auf dem Quellen UDV F r detaillierte Schritte zum Setup des Snapshots QSnap lesen Sie bitte unter Abschnitt 4 4 1 nach Beim Einstellen der Gr e des UDV Blocks geben Sie bitte 512 MB ein QCopy kann nur mit einer Blockgr e von 512 MB arbeiten Klicken Sie das QCopy Symbol beim ausgew hlten Snapshot QSnap UDV an Geben Sie die entfernte iSCSI Ziel IP ein klicken Sie Dan an und warten Sie einen Augenblick w hrend die Web GUI die Informationen des Ziel UDV und die entsprechende LUN empf ngt Wahlen Sie die entfernte Zell UN des Ziel UDV f r QCopy aus Sum _ Klicken Sie auf H Dann erscheint eine Nachricht in der der Benutzer gebeten wird zuerst das Ziel UDV vom Host Server zu
148. ge or temperature is out of the normal range For better data protection please check Auto Shutdown For better protection and to avoid single short period of high temperature triggering Auto shutdown GeViRAID controllers use multiple condition judgments for Auto shutdown below is the detail of when the Auto shutdown will be triggered 1 There are 3 sensors placed on controllers for temperature checking on core processor on PCI X bridge and on daughter board GeViRAID controller will check each sensor every 30 seconds When one of there sensor is over the high temperature value for continuous 3 minutes the Auto shutdown will be triggered immediately 2 The core processor temperature limit is 85 C The PCI X bridge temperature limit is 80 C The daughter board temperature limit is 80 C 3 If the high temperature situation doesn t last for 3 minutes the controller will not do auto shutdown dE 3 3 Hard drive SMART function support S M A R T Self Monitoring Analysis and Reporting Technology is a diagnostic tool for hard drives to give advanced warning of drive failures S M A R T provides users chances to take actions before possible drive failure S M A R T measures many attributes of the hard drive all the time and decide the hard drives which are close to out of tolerance The advanced notice of possible hard drive failure can allow users to back up hard drive or replace the hard drive This is much better than
149. hared Folders SS winbows2003 D Partition Basic FATS Healthy Boot 19 52 GB ES Local Users and Groups windows 2000 C3 Partition Basic NTFS Healthy System 19 53 GB 4 H lt SDisk 0 mee Basic Windows f WINDOW D E 24 1 QA TOOLS 74 50 GE 19 53GB N 19 53 GBF 919 4 15 90 GB F Online Healthy Sy 8 Healthy Bi ff hy Healthy Disk 1 Basic 152 07 GB 152 97 GB Online Unallocated ba E Unallocated RB Primary partition 9 Extended partition SS Logical drive EEE EEE Figure E 21 106 F MPIO and MC S setup instructions Here is the step by step to setup MPIO There are 2 kinds of scenarios for MPIO Please see Figure F 1 GeViRAID suggests using scenario 2 for better performance Network diagram of MPIO Read or Write Read or Write Read or Write LAN F series OSAN P series 1 Dual ports with MPIO 2 Dual ports with MPIO Direct connect host has 2 Via switches host has 2 LAWN ports read or write in LAN ports read or write in one UDV one UDV Figure F 1 The setup instructions are in the following figures 1 Create a VG with RAID 5 using 3 HDDs 107 Volume config Volume group Create e Delete e Ss Total Free SEH m No Name GB GB PD ZUDWV Status 12 3 RAID 4 Ra Online RAID 5S L a 5 Ke ge a _ pe Create D Delete e Figure F 2 2 Create a UDV by using RAID 5 VG Volume config User data volume
150. has been rebooted Info System shutdown Info System has been shutdown Info System Init OK Info System has been initialized OK system Init Failed Error System cannot be initialized in the last boot up e LVM events et Info VG Created OK Info VG lt name gt hasbeen create Warning VG Created Cal Warning Fail to create VG lt name gt Info VGDeleted Info VG lt name gt has been deleted _ Info UDV Created OK Info UDV lt name gt has been created Warning UDV Created Fail Warning Fail to create UDV lt name gt Info UDV Deleted____ Info UDV lt name gt has been deleted Info UDV Attached OK_ Info UDV lt name gt has been LUN attached Warning UDV Attached Fail Warning Fail to attach LUN to UDV lt name gt Info UDV Detached OK _ Info UDV lt name gt has been detached Zon orson EE ber gt SCSI_ID lt number gt LUN lt number gt m er ese Started ee lige PW oe eee Finished mem n il Fail ing m mer eem Started m RTE eo Finished em mn ee TEENS OO TRE Failed tion Warning VG Degraded Warning VG lt name gt is under degraded mode UDV Degraded Warning UDV lt name gt is under degraded mode Info UDVInitOK__ Info UDV lt name gt completes the initialization __ e e ee Initialization zation men laa ea UDV lt name gt Warning VG Failed Error Fail to access VG lt name gt Warning UDV Failed Error Fail to acce
151. hers could not use these dedicated spare disks for any rebuilding purpose Global Spare disks GS is shared for rebuilding purpose If some VGs need to use the global spare disks for rebuilding they could get the spare disks out from the common spare disks pool for such requirement Dedicated Cache e EE ec Global Cache Cache DeGraded mode Not all of the array s member disks are ii functioning but the array is able to respond to application read and write requests to its virtual disks rm samen _ 7 CHAP Challenge Handshake Authentication Protocol An optional security mechanism to control access to an iSCSI storage P system over the iSCSI data ports Internet Storage Name Service Serial Attached SCSI 1 3 RAID levels RAID 0 Disk striping GeViRAID RAID 0 needs at least one hard drive RAID 1 Disk mirroring over two disks RAID 1 needs at least two hard drives N way Extension to RAID 1 level It has N copies of the disk mirror RAID 3 Striping with parity on the dedicated disk RAID 3 needs at least three hard drives RAID 5 Striping with interspersed parity over the member disks RAID 3 needs at least three hard drives RAID 6 2 dimensional parity protection over the member disks RAID 6 needs at least four hard drives RAID 0 1 Mirroring of the member RAID 0 volumes RAID 0 1 needs at least four hard drives RAID 10 Striping over the member RAID 1 volumes RAID 10 needs at least four har
152. homed LAN Aggregation O Trunking LACP lt lt Back e Confirm e Figure E 11 11 Now the setting is LACP mode System config iSCSI ISNS e Authentication a No Port Aggregation DHCP IP address Netmask Gateway MTU MAC address LACH no 1500 i lag R 192 168 11 229 29 22 20 192 158 11 229 z 00 13 73 00 02 00 Entity name iqn 2004 08 tw com qsan p120c 000a00021 NS H Authentication e Figure E 12 12 Enable switch LACP function of port 21 and 23 Below is an example of Dell PowerConnect 5324 101 eas Dell OpenManage Switch Administrator Microsoft Internet Explorer reis System D ESCH M ult es at cy er Ko e Statistics RMON gesi Quality of Service a e kee Support Help About Log Out PoyerConnect 5324 ff Ports 1 2 3 4586 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Figure E 13 13 Add Target Portals in Microsoft iSCSI initiator 2 03 102 iSCSI Initiator Properties Figure E 14 14 Input the IP address of iSCSI data port 1 192 168 11 229 as mentioned in previous page Add Target Portal 192 166 11 229 Figure E 15 103 15 Click Targets to log on iSCSI Initiator Properties Deal 3 IECH TEINOWE Appi Figure E16 16 Log on iSCSI Initiator Properties co a a Mate u fon ppp Figure E 17
153. hwindigkeit als unbekannt defi niert e PD operations description Gibt das Laufwerk zur Verwendung frei 36 Definiert die Festplatte als Globales Spare fur alle VGs Global spares Definiert die Festplatte n als dedizierte Spare fur ausgewahl te VGs Auf dieser Seite verf gt der GEVIRAID Controller auch ber die Funktion HDD Auto Spindown Down um Energie zu sparen Der Standardwert ist deaktiviert Der Benutzer kann die Funktion auch auf der Seite einer Physical Disk festlegen Auto Spindown wird von GEVIRAID II unterst tzt Auto spindown Disabled Select F Free disks Global spares e Dedicated spares e rs Figure 3 6 2 2 Volume config Physical disk Auto spindown Auto spindown Disabled is 30 sec 1 min S min 30 min Abbildung 3 6 2 3 3 6 3 Volume group Um sich den Status der VGs anzusehen w hlen Sie Volume Group e VG Spalten Beschreibung Create e Delete a Total Free i No Name GB cB PD FUDY Status EE RAID 1 VWG RO z e o 297 267 4 1 Online Be 2 VG R6 Online RAID 6 8 e 148 128 4 1 man Zi Create D Delete A Abbildung 3 6 3 1 Abbildung 3 6 3 1 Es gibt ein RAID 0 mit 4 Physical Disks benannt VG RO die Gesamt gr e betr gt 297 GB der verf gbare Platz ist 267 GB es geh rt zu 1 UDV Ein weiterer RAID ist ein RAID 6 mit 4 Physical Disks benannt VG R6 37 Nummer der Volume Group Neben der Nummer befindet sich der Schalter fur die
154. iSCSI config Node Change Authentication Authentication None None Abbildung 3 5 3 4 Name Auth CHAF On 2004 08 tw com gsan p150c 000a8a001 default target e Abbildung 3 5 3 5 4 Wahlen Sie None um CHAP zu deaktivieren 31 Tips Nach der Einstellung von CHAP sollte der Initiator in Host Server auf dasselbe Konto bzw Passwort geandert werden Andernfalls kann sich der Benutzer nicht anmelden 3 5 4 Session Wahlen Sie die Funktion Session es werden die iSCSI Session und die Verbin dungsinformationen angezeigt Folgende Punkte werden allerdings nicht angezeigt 1 Host Initiator Name 2 Error Recovery Level 3 Error Recovery Level Delete e E No Initiator name TPGT Error recovery level Error recovery count CID D iqn 1987 05 com cisco 01 c047c42de54 0x02 T 0 1713 iqn 1987 05 com cisco 01 cO47 c42de54 0x02 0 0 Lj jz 0 iqn 1987 05 com cisco 01 c047c42de54 0x00 0 0 Delete a 4 Detail des Authentifizierungsstatus und Source IP Port Nummer Abbildung 3 5 4 1 Abbildung 3 5 4 1 iSCSI Session Klicken Sie auf die Taste um die Verbindung en anzuzeigen No Initiator IP Initiator name Authentication 0 192 168 12 212 qn 1987 05 c0m csco 01 c047c42de54 no lt lt Back a Abbildung 3 5 4 2 Abbildung 3 5 4 2 iSCSI Verbindung 32 395 CHAP Account W hlen Sie die Funktion CHAP Account um ein CHAP Konto f r die Au thentifizierung anzulegen bzw zu l schen GEVIRAID II kann nur ei
155. inem Host zugeordnet werden kann so dass diese UDV wie alle anderen zum Betriebssystem hin wie ein Laufwerk erscheint Die Rollback Funktion stellt Daten zu jedem Zeitpunkt wieder her zu dem vorher ein Snapshot gestartet wurde aus welchem Grund dies auch immer n tig sein kann Vi renangriffe versehentlich gel schte oder ge nderte Dateien Das Snap UDV wird im selben VG erstellt von dem der Snapshot erstellt wird Wir empfehlen f r Snapshots einen Speicherplatz von 20 zu reservieren Je nach Ihrer Anforderung kann aber auch mehr oder weniger erforderlich sein In Abb 4 4 1 ist ein Snapshot QSnap Konzept dargestellt GEVIRAID II unterst tzt snapshot rollback Gsen SorP series Osan 5 or F sares asan 5 or F series volume Snapshot Vaura 2pm 3 Mis Es ee cernir RPO 15 RTO 25 Mi Abbildung 4 4 1 Einrichten eines Snapshot QSnap volume Achtung Die Funktionen Snapshot QSnap Rollback ben tigen mindestens 512 MB RAM F r weitere Details siehe dazu die RAM Zertifizie rungsliste in Anhang A 64 Um einen Snapshot QSnap der Daten anzufertigen verfahren Sie bitte wie folgt 1 Gehen Sie zu Volume Config User Data Volume Klicken Sie in der Spalte Snapshot QSnap GB auf die Schaltfl che um die UDV auszuwahlen von der ein Snapshot QSnap angefertigt werden soll Sie werden nun zur Setup Seite weitergeleitet Der maximale Platz fur den Snapshot
156. ink no 192 1659 1 254 1500 LAMI e 192 168 1 1 799 205 255 0 e e U0 00 00 00 00 00 down no 192 169 2 254 1500 LANE e WE ee Weis Sch ale 2Sa Aaa m e U0 00 00 00 00 00 down Entity name Iqn 2004 08 tw com qsan pl00c 000a406bb Figure 3 5 2 4 Figure 3 5 2 2 P100C there are 2 iSCSI data ports MTU is 1500 P100C doesn t support Trunking LACP User can change IP address by clicking the button in the DHCP column There are 2 selections DHCP Get IP address from DHCP server or Static IP d iSCSI config NIC IP address DHCP Static Address 192 168 1 1 Mask EE EA Gateway 19 166 1 254 Figure 3 5 2 3 Default gateway can be changed by clicking the button in the Gateway column There is only one default gateway MTU Maximum Transmission Unit size can be changed by clicking the button in the MTU column iSCSI config WIC MTU LAN MTU Figure 3 5 2 4 There are some different of supporting MTU size on every models The range of MTU size on P200C P150C is between from 1500 to 8000 P120 is between from 1500 to 9000 But P100C is between from 1500 to 3900 Default MTU size is 32 1500 If it is changed the setting of MTU size on switching hub and HBA should be set to the same size Caution The MTU size of switching hub and HBA on host must be the same as controller Otherwise the LAN connection can not work properly In P200C P150C Trunking LA
157. isable Enable Wenn die Login Sperre aktiv ist erlaubt das Sys tem nur einem Benutzer sich anzumelden bzw die Systemeinstellungen zu ndern 23 system config Login config Auto logout Disable el DS BEES Disable Enable Abbildung 3 4 4 1 3 4 5 Password Im Men Password k nnen Sie das Administrator Passwort ndern Die maximale L nge des Admin Passwortes betr gt 12 Zeichen 3 4 6 Date System config Password Old password Password Confirm Abbildung 3 4 5 1 Wahlen Sie Date um vor der Verwendung oder der Zeitsynchronisation des NTP Network Time Protocol Servers das aktuelle Datum die Uhrzeit und die Zeitzone ein zustellen System config Date RR 16 16 15 Now Time zone Asia Taipel d Setup date and time manually Date 2007 B a Time 16 SG fr NTP server Abbildung 3 4 6 1 3 4 7 Mail W hlen Sie Mail um max 3 E Mail Adressen f r den Erhalt von Benachrichtungen bei Ereignissen einzugeben Einige Mailserver berpr fen die Option Mail from Address und erfordern f r die Anti Spam Funktion eine Authentifizierung F llen Sie bitte die notwendigen Felder aus und w hlen Sie Send Test Mail um zu pr fen ob das Versenden und Empfangen von E Mails funktioniert Sie k nnen auch ausw hlen welche Ebene der Ereignisprotokolle erforderlich ist damit diese per E Mail versendet 24 werden Die Standardeinstellung
158. ission Unit Challenge Handshake Authentication Protocol Ein optionaler Sicherheitsmechanismus f r die Steuerung des Zugriffs auf jedes iSCSI Storage System ber iSCSI Data Ports Internet Storage Name Service Serial Attached SCSI Disk Striping Daten werden auf mehrere Festplatten verteilt Ben tigt mindesten eine Festplatte Keine Datensicherheit Erweiterung des RAID Level 1 Eine Festplatte wird auf N Festplatten gespiegelt Daten werden ber mehrere Festplatten verteilt Paritatsdaten werden auf einem dedizierten Laufwerk abgelegt Ben tigt mindestens 3 Fest platten Daten und Parit tsinformationen werden ber alle Festplatten ver teilt Ben tigt mindestens drei Festplatten Wie RAID 5 Die Parit tsdaten sind hier doppelt vorhanden Ben tigt mindestens 4 Festplatten RAID 10 Daten werden ber mehrere RAID 1 Verb nde verteilt Ben tigt min destens vier Festplatten RAID 30 Daten werden ber mehrere RAID 3 Verb nde verteilt Ben tigt min destens sechs Festplatten RAID 50 Daten werden ber mehrere RAID 5 Verb nde verteilt Ben tigt min destens sechs Festplatten RAID 60 Daten werden ber mehrere RAID 6 Verb nde verteilt Ben tigt min destens acht Festplatten JBOD Abk rzung von Just a Bunch Of Disks Ben tigt mindestens eine Festplatte Kapitel 2 Erste Schritte 2 1 Vor dem Start Bevor Sie beginnen pr fen Sie bitte die folgenden Punkte Pr fen Sie anhand der Certification li
159. ity data replication multi path and high availability Storage protocol such as iSCSI has two ends in the connection These ends are the initiator and the target In iSCSI we call them iSCSI initiator and iSCSI I target The iSCSI initiator requests or initiates any iSCSI communication It requests all SCSI operations like read or write An initiator is usually located on the host server side either an iSCSI HBA or iSCSI SW initiator The iSCSI target is the storage device itself or an appliance which controls and serves volumes or virtual volumes The target is the device which performs SCSI commands or bridges it to an attached storage device iSCSI targets can be disks tapes RAID arrays tape libraries and etc Host 1 initiator NIC Host 2 initiator iSCSI HBA iSCSI device 1 target ISCSI device 2 target Figure 2 2 1 The host side needs an iSCSI initiator The initiator is a driver which handles the SCSI traffic over iSCSI The initiator can be software or hardware HBA Please refer to the certification list of iSCSI HBA s in Appendix A OS native initiators or other software initiators use the standard TCP IP stack and Ethernet hardware while iSCSI HBA s use their own iSCSI and TCP IP stacks on board Hardware iSCSI HBA s would provide its initiator tool Please refer to the vendors HBA user manual Microsoft Linux and Mac provide software iSCSI initiator driver Below are the availab
160. k D Confirm e Abbildung 3 6 7 5 1 Wahlen Sie ein UDV 2 Geben Sie Host ein Dies ist der Initiator Node Name f r die Zugangskon trolle Sie k nnen auch einen Platzhalter eingeben was bedeutet dass je der Host auf das Volume zugreifen kann W hlen Sie eine LUN und die Berechtigung Danach klicken Sie auf n Confirm 3 Fertig Attach e Detach amp a Host LUN Permission UDY name Session Li 0 Read write UDV RS 1 1 e LJ 19n 1991 05 microsoft com demoa 1 Read write UDY RS 2 0 Attach n Detach cn Abbildung 3 6 7 6 Abbildung 3 6 7 6 UDV R5 1 wurde auf LUN 0 zugewiesen jeder Host hat Zugriff UDV R5 2 wurde auf LUN 1 zugewiesen nur ein Initiator mit dem Node Name iqn 1991 05 com microsoft demo hat Zugriff Tips Die Regeln f r die bereinstimmung zur Zugangskontrolle gelten der Reihe nach von oben nach unten Weitere Details finden Sie unter 3 6 6 Schritt 4 Definieren einer Global Spare Disk So gehen Sie vor 1 Wahlen Sie Volume Config Physical Disk 2 Wahlen Sie durch Anklicken des Auswahlmen s in der jeweiligen Reihe eine freie Disk mehrere Disks aus dann klicken Sie auf lena SPERA um die Global Spares festzulegen 3 Inder Spalte Status 1 sehen Sie nun ein GS Icon 45 Global spares e Le act sl Fre 115 Kr Size YG u Slot MWMWN GB en L C a 00700135 7sa4d0040 33 w G R5 2 E z 2n117001373320299 38 wG RS C N 1180013789320249 38 WG 5 A A 201906001378
161. koll als Textdokument mit dem Dateina men log ModelName SerialNumber Date Time txt z B Log GEVIRAID 2 A00001 20070801 120000 txt gespeichert Wenn Sie die Taste Clear dr cken wird das Er eignisprotokoll gel scht Durch Klicken auf Mute wird der Alarm abgeschalten wenn vom System eine Warnmeldung erfolgt Filter D Download A Mute e Clear a INFO Wed 08 Aug 2007 18 04 25 CST UDY QUICK68809 has been created INFO Wed 08 Aug 2007 18 04 25 CST VG QUICK45427 has been created INFO Wed 08 Aug 2007 18 01 17 CST admin login from 192 168 10 121 via Web UI Abbildung 3 4 11 1 Um das Display des Ereignisprotokolls nach Ihren W nschen anzupassen k nnen Sie zwischen insgesamt drei Display Methoden w hlen auf der Web Ul Konsole Seite Er eignisprotokoll im Popup Fenster auf der Web UI und ber das LCM Die Standard einstellungen fur diese drei Ereignisprotokoll Displays lauten WARNING und ERROR und sind auf der Web UI und im LCM aktiviert Das Popup ist standardm ig deakti viert Show events INFOC WARNING M ERROR M Pop up events INFOC WARNING C ERROR C Show on LCM INFOC WARNING M ERROR M lt lt Back a Confirm e Abbildung 3 4 11 2 Das Ereignisprotokoll wird in umgekehrter Reihenfolge angezeigt das hei t das letzte Ereignisprotokoll erscheint auf der ersten Seite Das Ereignisprotokoll wird eigentlich auf den ersten vier Festplatten gepeichert jede Festplatte verfugt Uber eine Kopie eines Ereignis
162. l PowerConnect 5324 Dell PowerConnect 2724 S O Dell PowerConnect 2708 gt SSS O Hard drive P100C P120C P150C P200C support SATA I II disks Vendor Me y O BEE Seagate Barracuda 7200 7 ST380817AS 80G 7200RPM SATA 1 5Gb s 8M NCQ nae EE 7200 8 ST3400832AS 400G 7200RPM SATA 1 5Gb s 8M NCQ 85 a 7200 9 ST3500641AS 500G 7200RPM SATA 3 0Gb s 16M NCQ ES 2 ST31000340NS 1000G 7200RPM SATA 3 0Gb s 32M P200C supports SAS disk Vendor Mode o Fujitsu MAS202EbRC 36 7G 15000RPM SAS 3 0Gb s 16M Fujitsu MAX3073RC 73 5G 15000RPM SAS 3 0Gb s 16M Fujitsu MAX3147RC 147 0G 15000RPM SAS 3 0Gb s 16M fo 15K147 HUS151436VLS300 36G 15000RPM SAS 3 0Gb s 16M some of SAS commands in Fujitsu SAS disks do not follow SAS standard Although the controller has workaround this problem Fujitsu SAS disks are not recommended B Event notifications e PD S M A R T events Description OO Disk inserted nfo Disk lt slot gt is inserted nfo Disk lt slot gt is removed S M A R T Warning Disk lt slot gt S M A R T threshold threshold exceed exceed condition occurred for attribute of condition 1 read error rate 2 spin up time 86 reallocated sector count seek error rate spin up retries calibration retries S M A R T Warning Disk lt slot gt Failure to get S M A R T information information e Physical HW events en en EEN
163. l number 3 8 3 Reset to default Enter Reset to default function it allows user to reset controller to the factory default setting Sure to reset to factory default Contirm e Figure 3 8 3 1 Reset to default sets password to default 1234 and set IP address to default as DHCP setting Default IP address 192 168 201 150 DHCP Default subnet mask 255 255 255 0 Default gateway 192 168 201 254 66 3 8 4 Config import amp export Enter Config import amp export function it allows user to save system configurable values export function and to apply all configuration import function For the volume config setting the values are available in export function and not available in import function which can avoid confliction date deleting between two controllers That says if one controller already has valuable data on the disks and user may forget it use import function could return to the original config If the volume setting was also imported the user s current data will be cleared Import Export TE et ea ae F KITO Import file Browse Import Logical unit only Export Confirm e Figure 3 8 4 1 Import Import all system configurations excluding volume config Import Logical unit only No system and volume configurations import LUN configurations only 3 Export Export all configurations to a file N Caution Import function will import all system configurations excluding
164. latte hat defekte Bl cke FAIL gt Die Festplatte kann nicht im gew hlten Volume arbeiten RD gt RAID Disk Diese Festplatte wurde auf RAID ge setzt FR gt FRee disk Diese Festplatte steht zur freien Verf gung DS gt Dedicated Spare Diese Festplatte ist eine dedizier te Spare f r ein VG GS gt Global Spare Diese Festplatte ist ein Global Spa redrive f r alle VGs RS gt ReServe Diese Festplatte enth lt VG Informatio nen kann aber nicht verwendet werden M gli cherweise wird dies durch ein unvollst ndiges VG Set oder durch das Warmlaufen dieser Disk w h rend der Betriebszeit verursacht Um die Daten auf der Disk zu sch tzen ndert sich der Status auf Reserve Um Sie neuerlich zu verwenden muss die Einstellungen manuell auf FR ge ndert werden R gt Rebuild Die Festplatte befindet sich im Rebuild M gt Migration Die Festplatte wird migriert 3 0G gt Beim SATA ATAPI Standard falls die Disk den Be fehl ATAPI IDENTIFY PACKET DEVICE unterst tzt und die Geschwindigkeit die Serial ATA Gen 2 Sig nalgeschwindigkeit 3 0 Gbps erreichen kann 1 5G gt Beim SATA ATAPI Standard falls die Disk den Be fehl ATAPI IDENTIFY PACKET DEVICE unterst tzt und die Geschwindigkeit die Serial ATA Gen 1 Sig nalgeschwindigkeit 1 5 Gbps erreichen kann Speed Unknown gt Der obige Befehl wird von der Disk nicht unter stutzt daher wird die Gesc
165. le links 1 Link to download the Microsoft iSCSI software initiator http www microsoft com downloads details aspx FamilyID 12cb3c1a 15d6 4585 b385 befd1319f825 amp DisplayLang en Please refer to Appendix D for Microsoft iSCSI initiator installation procedure 2 Linux iSCSI initiator is also available For different kernels there are different iSCSI drivers Please check Appendix A for software iSCSI ce initiator certification list If user needs the latest Linux iSCSI initiator please visit Open iSCSI project for most update information Linux ISCSI sfnet and Open iSCSI projects merged in April 11 2005 Open iSCSI website http www open iscsi org Open iSCSI README http www open iscsi org docs README Features http www open iscsi org cgi bin wiki pl Roadmap Support Kernels http www open iscsi org cgi bin wiki pl Supported_Kernels Google groups http groups google com group open iscsi threads gvc 2 http groups google com group open iscsi topics Open iSCSI Wiki http www open iscsi org cgi bin wiki pl 3 ATTO iSCSI initiator is available for Mac Website http www attotech com xtend html 2 3 Management methods There are three management methods to manage P Series controller describe in the following 2 3 1 Web GUI P Series controllers support graphic user interface to manage the system Be sure to connect LAN cable The default setting of management port IP is DHCP and the DHCP address displa
166. len z B Sensoren f r Temperatur Spannung Festplatten Bel ftung Energieversorgung und zur berwachung des LED Status Aufgrund der unterschiedlichen Hardware Eigenschaften dieser Sensoren bestehen f r die unterschiedlichen Sensoren verschiede ne Abfrageintervalle Nachstehend finden Sie detaillierte Angaben ber die Zeitintervalle der Abfrage Temperatursensoren 1 Minute Spannungssensoren 1 Minute Festplattensensoren 10 Minuten Bel ftungssensoren 10 Sekunden Bei 3 aufeinanderfolgenden Fehlermeldun gen sendet der Controller ein ERROR Ereignisprotokoll Energieversorgungssensoren 10 Sekunden Bei 3 aufeinanderfolgenden Fehler meldungen sendet der Controller ein ERROR Ereignisprotokoll 6 LED Status 10 Sekunden RON GA SES config Access control for SES management Hardware monitor System monitored voltage temperature and battery backup module 5 M A R T Self monitoring analysis and reporting technology for physical disks UPS Uninterruptible power supply Abbildung 3 7 1 3 1 SES Konfiguration SES bedeutet SCSI Enclosure Services einer der Standards f r das Enclosure Ma nagement Durch die Auswahl der Funktion SES Config k nnen Sie das SES Ma nagement aktivieren oder deaktivieren Enable b Disable a a Host LUN Permission UDY name 8 ia oO Read write SES Enable e Disable e Abbildung 3 7 1 1 Abbildung 3 7 1 1 Aktivieren Sie SES in LUN 0 Zugriff ist nun durch jeden Host moglich Die SES
167. lert via Windows messenger not MSN User must enable the service Messenger in Windows Start gt Control Panel gt Administrative Tools gt Services gt Messenger and then event logs can be received It allows up to 3 messenger addresses User can choose the event log levels and the default values are WARNING and ERROR event logs enabled only System contig Messenger Messenger IP hostname 1 Messenger IP hostname 2 Messenger IP hostname 3 Send events INFO TI WARNING ERROR Figure 3 4 9 1 3 4 10 System log server Select System log server to set up alert via syslog protocol The default port of syslog is 514 User can choose the facility and the event log level The default values of event level are INFO WARNING and ERROR event logs enabled System config System log server Server IP hostname Port SE Facility Local4 sl Event level INFOM WARNING M ERROR MY Figure 3 4 10 1 There are some syslog server tools The following web sites are for reference WinSyslog http Awww winsyslog com 28 Kiwi Syslog Daemon http www kiwisyslog com Most UNIX systems build in syslog daemon 3 4 11 Eventlog Select Event log to view the event messages Press Filter button to choose the display Press Download button will save the whole event log as text file with file name log ModelName SerialNumber Date Time txt e g log P200C A00001 20070801 120000 txt Pres
168. locking filter SS Telecontrol p Time ranges K Hardware E Database auto backup 8 Licenses Schritt 4 ffnen Sie die Event Settings und konfigurieren Sie die Start by Sequenz Schritt 5 Offnen Sie die Alarm Settings und stellen Sie Ihre St rungsmeldung ein General settings KE W Media channels Yio settings yEvent settings rm sen gt zeng O o H Quality profiles Q Behavioural rule Y Blocking filter SS Telecontrol p Time ranges St rung RAID System Schritt 5 Linksklick auf Alarm amp Hardware Database Ra backup Or User Licenses ri CM 85 Schritt 6 Zum Test Ihrer erfolgreichen Einstellung der GeViRAID St rungsmeldung ffnen Sie bitte GSC View Entfernen Sie nun z B ein Netzteil an Ihrem GeViRAID Nach circa 45 Sekunden sollte die von Ihnen konfigurierte St rungsmeldung auf Ihrem GSCView Bildschirm erscheinen H cf My Docur RI GscView ae E File 2 en Vi wer uch EE E TLL LIATI A Ae WT Be ge l Schritt 6 Video servers a St rungsmeldung ix Local e WEE Quittieren Sie mit Confirm alarm My Comp Wieren on server lt Local gt Kl Erar nzl wlio OS 2006 09 29 30 A Confirm X remove H cl Sesame Loaded pro file gp GEVISCG Windows XP Embedded Build 2600 xpsp_sp2_rtm 040803 2156 Service Pack 2 Trap Receiver Me rtanview Zwischen Wissesetup Bestatigen
169. lower Emer PSU Fail Error Power lt number gt is out of work Emer FanFail Error Fan lt number gt is out of work Error Fannon exist Error System cooling fan is not installed Error _ AC Loss _____ Error AC loss for the system is detected Info UPS Detection OK Info UPS detection succeed ____ Warning UPS Detection Fail Error ACloss Error AC lossforthesystemisdteced pe Uer erst auto shutdown immediately Active mama paea i TT Failed LAN Port Warning RTC Access Failed_ Warning Fail to access RTC device Info Reset Password 1 Info Reset Admin Password to default System config events C eg C Info Sys Config Info Default system configurations restored Defaults Restored Sys NVRAM OK Info The system NVRAM is active Sys NVRAM IO Error Cant access the system NVRAM Failed Warning Sys NVRAM is full Warning The system NVRAM is full 88 e System maintenance events el _ Type __ EE Upgraded ee Upgraded Failed System reboot Info System has been rebooted System shutdown Info System has been shutdown System Init OK Info System has been initialized OK system Init Failed Error System cannot be initialized in the last boot up e LVM events aS St See eS eee eee Warning VG Created Fail Warning Fail to create VG lt name gt Warning UDV Created Fail Warning Fail to create UDV lt name gt Warning UDV Attached F
170. lthy Boat Healthy Healthy zP Disk 1 Basic 2792 92 GB Gawen ta Dynamic Disk 744 96 GB Online Cowert to GPT Disk Unallocated Sicp romo Properties DWD goap Dep Online Healthy Figure H 19 5 Format disk 2 D Bee a 19 53 GB FAT3Z 19 53 GB FAT3Z Bee 53 GB E a GB NTFS ehr System U 5 Healthy System bt EEN BE Boot Bews a EE E ER E ER Rew i Partitio Mas Propertie DVD EN_05_2939 2 G Help 3 20 GB 3 20 GB UDF Healthy Figure H 20 6 Format disk is done 138 Disk 0 I Basic Boe a 76 68 GB Gs 2 GB FATS2 e a GB FATS2 19 53 GB 16 08 GB NTFS Online Healthy System Seme Boot Boe Healthy Disk 1 Basic 2792 87 GB a Online Healthy oo yy Sco Romo DD EN_OS_ 2939 2 Gi 3 20 GB 13 20 GB UDF Online Healthy Figure H 21 7 The new disk is ready to go available size 2 72TB File Edit View Favorites Tools Help GD Back Es kA J Search gt Folders Ok O P P search O Foes gt xl 39 2 amp I Mr O C ee Disk Drives Local Disk C Local Disk 19 5 GB 17 0 GB gt Local Disk D Local Disk 19 5 GB 16 2 GB Local Disk E Local Disk local Disk F Local Disk 13 0 GB 16 4 GB iNew Volume H Local Disk 2 72 TB 2 72 TB Devices with Re H ae Floppy A seen SSEN_05_27939 2 G CD Drive 3 20 GB 0 bytes Figure H 22 Caution if user se
171. lue Sender ID EHRT EN 192 168 201 150 Trap Receiver Action Add Watch Actions Sender IP ka Explode w ul osare Add Modify Delete Equals E mal 192 168 201 150 Discard Add Executable EJ Cancel C Tools Gevi RADA failure bat Frogram Trap aromen Include Trap Data Mame ze Type OD TrapReceiver Fie Folder failure bat IKB MS DOS Batch File Configure the batch file net send lt computer name gt lt message gt failure bat Notepad em File Edit Format view Help net send pm4 failure RAID System computer name 145 1 1 3 Network Connections Windows Firewall First solution g General Exceptions Advanced Your PC is not protected turn op Windows Firewall Windows Firewall helps protect your computer by preventing unauthorized users from gaining access to your computer through the Internet or a network E COn recommended This getting blocks all outside sources from connecting to this computer with the exception of those selected on the Exceptions tab Don t allow exceptions Select this when vou connect to public networks in less secure locations such as airports ou wll not be notified when Windows Firewall blocks programs Selections on the Exceptions tab wll be ignored Avoid using this setting Turning off Windows Firewall may make this computer more vulnerable to viruses and intruders What else should know about Windows Firewall
172. m GeViRAID controller connects to the host system in iSCSI interface It can be configured to any RAID level P series controller provides reliable data protection for servers and the RAID 6 function ready The RAID 6 function allows two HDD failures without any impact on the existing data Data can be recovered from the remaining data and parity drives Data can be recovered from the rest disks drives Snapshot on the box QSnap is a fully usable copy of a defined collection of data that contains an image of the data as it appeared at the point in time which means a point in time data replication It provides consistent and instant copies of data volumes without any system downtime GeViRAID Snapshot on the box QSnap can keep up to 32 snapshots QSnap for all data volumes Rollback feature is provided for restoring the previously snapshot QSnap data easily while continuously using the volume for further data access The data access is regular as usual including read write without any impact to end users The on the box terminology implies that it does not require any proprietary agents installed at host side The snapshot QSnap is taken at target side and done by GeViRAID controller It will not consume any host CPU time thus the server is dedicated to the specific or other application The snapshot QSnap copies can be taken manually or by schedule every hour or every day depends on the modification QCopy service is to buil
173. me group Sets of physical disks with RAID functions User data volume Slices of volume groups Cache volume Dedicated or global cache space for user data volume Logical unit Target volumes for hosts access Figure 3 6 1 40 Volume relationship diagram UDV 1 UDV 2 Global CV Dedicated CV The above diagram describes the relationship of RAID components One VG Volume Group consists of a set of UDVs User Data Volume and owns one RAID level attribute Each VG can be divided into several UDVs The UDVs from one VG share the same RAID level but may have different volume capacity Each UDV will be associated with one specific CV Cache Volume to execute the data transaction Each CV could have different cache memory size from users modification setting LUN is the logical volume unit which the users could access through SCSI commands 3 6 2 Physical disk Enter Physical disk to view the status of hard drives inserted in the system The following are operation tips 1 Multiple select Select one or more checkboxes in front of the slot number Or select the checkbox at the top left corner will select all Check again will select none 2 The list box will disappear if there is no VG or only VG of RAID 0 JBOD Because these RAID levels cannot be set as dedicated spare disk 3 These three functions Free disks Global spares Dedicated Spares can do multiple selects too 4 The operations of the othe
174. n 2004 08 tw com gqsan p150c 000a8a001 default target Figure 3 5 3 1 Figure 3 5 3 1 P100C P120C P150C single mode P200C supports multi node There is no default node name on P200C it is empty It must be created first and then P200C can be used When using Quick install function a node name like iqn 2004 08 tw com qsan p200c XXXXXXXXxX targetO will be created automatically User Si Create m Delete a Name Auth Portal all Mone 192 168 11 227 3260 192 163 12 227 3260 a s 192 168 13 2273260 192 168 14 22 73260 1112 None E e ge 192 168 11 227 3260 192 168 12 227 35260 1314 None IR 192 155 13 227 3260 192 165 14 227 3260 r iqn 2004 08 tw com qsan p200c 000a6d021 targetO0 None 192 168 11 227 3260 192 168 12 227 3260 a 192 168 13 227 3260 192 1658 14 227 3260 User m Create e Delete e Figure 3 5 3 2 Figure 3 5 3 2 P200C multi node There are four nodes 35 d iSCSI config Node Create Name Authentication None sl Portal 192 168 1 1 3260 LAN 1 DHCP no MTU 1500 3 192 168 2 1 3260 LAN 2 DHCP no MTU 1500 192 168 3 1 3 60 LAN 3 DHCP no MTU 1500 192 168 4 1 3260 LAN 4 DHCP no MTU 1500 Figure 3 5 3 3 Figure 3 5 3 3 P200C press Create to create a node CHAP CHAP is the abbreviation of Challenge Handshake Authorization Protocol CHAP is a strong authentication method used with point to point for user login It s a type of authen
175. n CHAP Konto anlegen Z iSCSI config CHAP account Create User chapi max 223 Secret eee eee min 12 max 16 Confirm ded ok oo oR ae oR OR oe oe oe min 12 max 16 Abbildung 3 5 5 1 Abbildung 3 5 5 1 GEVIRAID Il klicken Sie auf Create um ein CHAP Konto anzulegen Create Deletes D E User r aap Create D Delete n Abbildung 3 5 5 2 Abbildung 3 5 5 2 GEVIRAID Il legt ein CHAP Konto mit dem Namen chap1 an 3 6 Volume configuration Die Auswahl Volume Config dient zur Einstellung der Volume Konfigurationen ein schlie lich Physical Disk Volume Group User Data Volume Cache Volu me und Logical Unit Funktionen Physical disk Hard disks to store data Volume group Sets of physical disks with RAID functions User data volume Slices of volume groups Cache volume Dedicated or global cache space for user data volume Logical unit Target yolumes for hosts access Abbildung 3 6 1 33 3 6 1 Volume relationship diagram UDV 1 UDV 2 Snap UDV Gi Gebai cv Dedicated CV Das Diagramm beschreibt die Beziehung der einzelnen RAID Komponenten zueinander Eine VG Volume Group besteht aus einem Set von PD Physical Disk und hat einen RAID Level Jedes VG Kann in mehrere UDV s aufgeteilt werden Die UDV s eines VG teilen sich den gleichen RAID Level k nnen aber in der Kapazit t unterschiedlich gro sein Jedes UDV wird einem einzigen CV Cache Volume f r die
176. n Sie die M glichkeit eine UPS Uninterruptible Power Supply ein zurichten UPS Type None Shutdown Battery Level 5 hi Shutdown Delay s o 8 Shutdown UPS OFF sl Status Battery Level 0 Contirm a Abbildung 3 7 4 1 54 Aktuell wird vom System nur die Smart UPS Funktion von APC American Power Con version Corp unterst tzt Weitere Informationen finden Sie unter http www apc com Verbinden Sie zun chst das System und die APC UPS ber den RS 232 Port Dann richten Sie die Werte ein f r das Herunterfahren des GeViRAID II bei einem Stromaus fall UPS anderer Hersteller arbeiten evtl auch ohne Probleme das muss jedoch von Fall zu Fall gepr ft werden UPS Type Auswahl des UPS Typs Smart UPS f r APC None f r ande re Hersteller oder keine UPS Shutdown Wenn die Grenze unterschritten wird schaltet sich das Sys Battery Level em aus Das Setzen dieses Levels auf 0 deaktiviert die UPS Funktion Shutdown F llt der Strom aus und wird innerhalb dieser Zeit der Strom Delay s nicht wieder hergestellt f hrt das GeViRAID II herunter Das Setzen dieses Wertes auf 0 deaktiviert die UPS Funktion Wenn ON gew hlt ist wird die UPS bei einem Stromausfall nach dem erfolgten Herunterfahren des Systems ebenfalls heruntergefahren Ist die Stromversorgung wieder hergestellt startet die UPS neu und benachrichtigt das System wieder hochzufahren Wenn OFF gew hlt ist erfolgen diese Vorg n ge nich
177. n Sie einen oder mehrere Snapshots QSnap Details hierzu finden Sie in Abschnitt 4 4 1 3 Klicken Sie in der Spalte Snapshot QSnap GB auf um ein Rollback der Daten durchzuf hren so k nnen Sie Daten zum Zeitpunkt der Snapshot Erstellung QSnap wiederherstellen Es gelten die folgenden Randbedingungen f r die Nutzung von Rollback 1 Minimum 512MB RAM 2 Vor einem Rollback steht das originale UDV kurzzeitig nicht zur Verf gung Das GeViRAID II verbindet Original UDV und Snap UDV und startet dann den Rollback 3 Wahren des Rollback kann auf die Daten des Original UDV zugegriffen werden Diese stellen bereits den Stand zum Zeitpunkt des Snapshots dar Auf das entsprechende Snap UDV kann nun nicht mehr zugeriffen werden 4 Nach erfolgreichem Rollback wird das entsprechende Snap UDV gel scht und die Snapshot Qsnap Gr e auf 0 zur ckgesetzt Achtung Bevor das Rollback ausgef hrt wird wird empfohlen das Dateisys tem zu dismounten damit zuerst die Daten vom Cache Speicher zu den Disks im Betriebssystem bertragen werden Der GEVIRAID Controller zeigt auch eine Popup Nachricht an wenn der Benutzer die Rollback Funktion ausw hlt 4 5 QCopy Remote Replikation GEVIRAID QCopy dient dem Aufbau eines gesch tzten Replikationsmechanismus f r er stellte UDVs Es kopiert die logischen User Volume Data genau an die entfernte Stelle Bei QCopy handelt es sich um ein integriertes Service ohne Host abh ngi
178. nd set priority finally click P Confirm B 4 Done A UDV using dedicated cache has been created Br Attach e Snapshot Create e Delete e i No Name SIZE Shatius 1 E a R RAID LUN Snapshot VG CE GE Jo GB name MB 1 UDY RS 1 50 i Gws OHI 0 00 0 00 Online Ge Les e uae PEN 5 ume 3 UDY R5 2 GA we HI 0 00 0 00 a e B WEI S _ 81 5 RAIDS 0 gt vG5S 20 Attach e Snapshot Create e Delete e Figure 3 6 7 11 Figure 3 6 7 11 UDV named UDV R5 1 uses global cache volume 40MB and UDV R5 2 uses dedicated cache volume 20MB UDV R5 2 is initialing about 5 Create e Delete e No Size UDY name 1 40 Global 2 Zu C e m UDY RS 2 Free 603 MB Create e Delete e Figure 3 6 7 12 Figure 3 6 7 12 In Volume config Cache volume UDV named UDV R5 2 uses dedicated cache volume 20MB Step 4 Attach LUN to UDV Please refer to Step 3 of Example 1 to attach LUN Step 5 Set dedicated spare disk To set dedicated spare disks please follow the procedures 1 Select Volume config Physical disk 2 Select a VG from the list box then select the free disk s click Dedicated spares to set as dedicated spare for the selected VG 3 There is a DS icon shown up at status 1 column 58 Select 5 Free disks Global spares e Dedicated spares e u Slot WWN See ae Status 1 2 Speed 1 Good 007001378340040 38 WG R5 fi op 1 566 Good BR
179. ndardgr e der MTU betr gt 1500 Wenn diese ge ndert wird sollte die Ein stellung der MTU Gr e auf dem Switching Hub und auf dem HBA denselben Wert aufweisen Achtung Die MTU Gr e des Switching Hub und des HBA auf dem Host muss der des Controllers entsprechen Andernfalls k nnte die LAN Verbindung nicht ordnungsgem funktionieren 29 Beim GEVIRAID II k nnen die Trunking LACP Einstellungen durch Anklicken der Taste in der Spalte Aggregation ge ndert werden iSCSI config NIC Aggregation Multi homed Aggregation Trunking C LACP Abbildung 3 5 2 7 Abbildung 3 5 2 7 GEVIRAID Il w hlen Sie den Aggregation Modus 1 Multi homed Standard Modus Jeder der iSCSI Data Ports ist mit sich selbst verbunden und befindet sich nicht im Modus Aggregation Die Auswahl dieses Modus kann Trunking LACP Einstellungen entfernen 2 Trunking definiert die gleichzeitige Nutzung von mehrfachen iSCSI Data Ports um die Link Geschwindigkeit ber die Limits der einzelnen Ports zu er h hen 3 LACP Das Link Aggregation Control Protocol LACP ist Teil der IEEE Spezification 802 Sad welche es erlaubt unterschiedliche physikalische Ports zu einem einzelnen logischen Kanal zu verbinden LACP erlaubt einem Net work Switch einen automatischen Bundle durch Versand von LACP Paketen zu einem Peer zu verhandeln Die Vorteile von LACP sind 1 die Erh hung der Bandbreite 2 und ei ne Ausfallssicherung wenn d
180. nfiguration und errechnet sich aus der Speichergr e abz glich des vom System genutzten Speichers E Mo size UDW name r cae Global Free O CMB Lre ts mn Delete Abbildung 3 6 5 1 e CV Spalten Beschreibung Nummer des Cache Volume Mit dem Schalter More Information neben der CV Nummer k nnen Sie sich weitere Details des Cache Volume ansehen Size MB Gesamte Kapazit t des Cache Volume Der Schalter neben der CV Gr e f hrt zur Resize Funktion Dadurch kann die CV Gr e angepasst werden UDV Name Name des UDV e CV Operationen Erstellt ein neues Cache Volume L scht ein neues Cache Volume Wenn kein freier Platz f r die Erstellung eines neuen Dedicated Cache Volume verf g bar ist verringern Sie zuerst die Gr e des Global Cache Nach der Gr en nderung kann ein Dedicated Cache Volume erstellt werden 41 Tips Die Mindestgr e f r ein Global Cache Volume betr gt 40 MB jene f r ein dediziertes Cache Volume betr gt 20 MB 3 6 6 Logical unit number Gehen Sie in Logical Unit um den Status der verbundenen LUN s jedes UDV zu se hen Attach E y Benutzer k nnen durch Anklicken von die verbundenen LUNs sehen Bitte sehen Sie sich Abbildung 3 6 6 1 an Um auf die Steuerung zuzugreifen muss der Initiator Node Name Host oder ein Platzhalter eingeben werden Letzteres bedeutet dass jeder Host auf das Vo lume zugreifen kann W hlen Sie die LUN Nummer
181. ngezeigt erstellt Fertig Sie k nnen nun das System nutzen e Snapshot D Create D Uppre C Nou Name ay Staus 2 af rap suun ropero T a i uIcKEse09 609 Dep Du 0 00 0 00 H D ce ei I e s RADO 1 A QUICK4S427 663 Attach Snapshot Create n Deets Abbildung 3 3 2 Abbildung 3 3 2 A RAID 0 user data volume mit dem UDV Namen QUICK68809 benannt vom System mit der total verf gbaren Laufwerksgr e 609GB 21 3 4 System configuration Die Auswahl System Config dient zur Einstellung von System Name IP Addresse Sprache Login Config Passwort Datum Mail SNMP Messenger System Log Server und um das Event Log anzusehen System name System name for identification IP address Internet Drotocol ID address for remote administration Language Language preference for WebUI Login config Configuration for auto logout and login lock Password Administrator s password Date System time for event log Mail Alert by e mail SNMP Alert via Simple Network Management Protocol SNMP Messenger Transmits net send and Alerter service messages between clients and servers System log server Alert to remote system log server Eventlog System event log to record critical events Abbildung 3 4 1 3 4 1 System name Um den Namen des Systems zu andern wahlen Sie System Name Der vom Sys tem automatisch vergebene Name setzt sich zusammen aus Modell und Seriennum mer z B S120C A00001 System
182. o allocate snapshot QSnap QSnap Mem memory for UDV lt name gt Failed Allocate Snapshot Warning Fail to allocate snapshot QSnap QSnap Space space for UDV lt name gt Failed Reach Snapshot Warning The threshold of the snapshot QSnap Threshold QSnap of UDV lt name gt has been reached Snapshot QSnap Info The snapshot QSnap of UDV lt name gt Delete has been deleted Snapshot QSnap Info The oldest snapshot QSnap version of replaced UDV lt name gt has been replaced by the new one Take a Snapshot Info Take a snapshot QSnap to UDV lt name gt QSnap Set Size for Snap Info Set the snapshot QSnap size of UDV shot QSnap lt name gt to lt number gt GB Snapshot QSnap Info The snapshot QSnap of UDV lt name gt rollback start rollback start Snapshot QSnap Info The snapshot QSnap of UDV lt name gt rollback finish rollback finish QCopy events ee SS eee EE SS SaaS QCopy Starts Info QCopy start Target lt node name gt IP x X X X Type Duplicate QCopy Restarts Info QCopy restart Target lt node name gt IP x X X X Type Duplicate Warning QCopy Connection Warning QCopy connection fail 19 Down keent QCopy Connection Warning Nang OCW SSS task was aborted Retry QCopy Task Set Warning QCopy task was aborted reason ting UDV LBA block size ONLY support 512 bytes C Bekannte Probleme 1 Microsoft MPIO funktioniert
183. o set up SNMP trap for alert via SNMP It allows up to 3 SNMP trap addresses Default community setting is public Remote PC GeviScope SNMP trap address 1 attach IP Adress and UDP Port 162 192 168 201 10 162 GeWVIRAID System config Z SNMP ef uick install 2 System config System config Systern nane SNMP trap address 1 192 168 201 100 162 IF a d d fe SNMP trap address 2 ECS SNMP trap address 3 Login config il ne Community i public S F A WE EE T ae K S Date 1 1 2 Remote PC GeViScope configuration Install the software SNMP Receiver Tool TrapReceiverV5 00 exe download internet or a SNMP receiver tool of your own choice E Setup Ze NETWORK COMPUTING DE Welcome kg W I Welcome to the Trap Receiver Setup Program This een To avoid problems please close all running Windows programs before adi Sei Click Cancel to og Setup Click Next to continue 142 Start program TrapReceiver Click on Start Services button of Trap Receiver Alert and start the Windows Messenger Make settings as shown below Trap Receiver Alert Trap Receiver Service is not running es Em Em de E ee m File Aion View Window Help de Sm Description Status Startup Type P Saraga Sy Indexing Service Indexes contents and properties of files Disabled d Removable storage ity IPSEC DErvice
184. oder Trunking ausgew hlt wurde Wenn einer oder mehrere Ports auf den Modus Link Aggregation oder Trunking gesetzt sind werden sie f r die Anzeige am Bildschirm in einer Zeile zusammengefasst No Port Aggregation DHCP IP address Netm sk Gateway MTU MAC address ne no 1500 1 LANI 192 168 11 193 255 255 755 0 192 168 11 254 8 00 13 78 00 07 04 no no 197 168 12 254 1500 2 LAN o 192 168 12 193 255 255 255 0 z 00 13 78 00 07 05 Entity name ign 2004 08 tw com gsan p120c 000a205e2c Abbildung 3 5 2 3 Abbildung 3 5 2 3 GEVIRAID Il es gibt 2 iSCSI Data Ports MTU ist 1500 28 Der Benutzer kann die IP Adresse durch Anklicken der Taste a in der Spalte DHCP ndern Es gibt 2 Auswahlm glichkeiten DHCP Erhalt der IP Adresse vom DHCP Server oder statische IP iSCSI config NIC IP address C DHCP Static Address 192 168 1 1 Mask te e pa Tereba Gateway 192 165 1 254 Abbildung 3 5 2 3 m 1 Der Default Gateway kann durch Anklicken der Taste in der Spalte Gateway ge ndert werden Es gibt nur einen Standard Gateway Die Gr e der MTU Maximum Transmission Unit kann durch Anklicken der Taste a in der Spalte MTU ge ndert werden iSCSI config NIC MTU 2000 4000 6000 S000 Abbildung 3 5 2 4 Es gibt bei jedem Modell unterschiedliche Wege die Gr e einer MTU zu unterst tzen Die Bandbreite der MTU Size beim GEVIRAID II schwankt zwischen 1500 und 9000 Die Sta
185. ollowing figures For the target side setting the steps are exactly the same as MPIO Please refer to Figure F 1 to Figure F 9 AS oa Create a VG with RAID 5 using 3 HDDs Create a UDV by using RAID 5 VG Run Microsoft iSCSI initiator 2 03 and check the Initiator Node Name Attaching LUN to R5 UDV Input the Initiator Node Name in Host field The volume config setting is done Check iSCSI settings The IP address of iSCSI data port 1 Is 192 168 11 229 port 2 is 192 168 12 229 for example Add Target Portals on Microsoft iSCSI initiator 2 03 Input the IP address of iSCSI data port 1 192 168 11 229 as mentioned in previous pages For MC S there is only ONE Target Portals in the Discovery tab 120 iSCSI Initiator Properties 119216811220 260 Default gt EIERE AEN E Figure F 24 9 Logon iSCSI Initiator Properties zu fic bicalliiiedet Inactive op ze d Figure F 25 121 10 Then click Advanced 7 Log On to Target Figure F 26 122 11 Select set Local Adapter Source IP and Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Advanced Settings d We E spez en Hes eme target 15 CHAP a seet haty Jaz IL antia fig a D I the Lem SL Tor thts Initiator Username l rgelsectetz 17 Eeron mutual authentication Tio use mutual CHAR specify aR Maton secretam tie itiatarrs Settings Page and cantigure hata etetan the taget
186. olume Config User Data Volume 2 Erstellen Sie Platz fur einen Snapshot QSnap Details hierzu finden Sie in Ab schnitt 4 4 1 3 Klicken Sie in der Spalte Snapshot QSnap GB auf um Auto Snapshot QSnap einzurichten 4 Auto Snapshots QSnap k nnen in monatlichen w chentlichen t glichen oder st ndlichen Abst nden erstellt werden 5 Fertig Snapshots QSnap werden nun automatisch erstellt Volume contig User data volume Auto Snapshot all Hoi Hoz Hoa Mina klos Flos Ho Mos Flos lun lu Hliz Months to take snapshots Weeks to take snapshots Ze a Dia Oa Cs O ail Days to take snapshots Eisin Omen O Tie Owed ClThu Fri Sat Can Ooo Cori Ooz Co Cloa Oos Oos Cie Hours to take snapshots Cios Doe Oio Oi Miz Oia Ois O15 Ce Oi Oia Ois Ciz0 Dai Oz Olas Back Confirm D Abbildung 4 4 2 1 Abbildung 4 4 2 1 Snapshots QSnap werden monatlich angefertigt und die letzten 32 Snapshot Kopien QSnap werden aufbewahrt Tips Der tagliche Snapshot QSnap wird jeden Tag um 00 00 Uhr erstellt Der w chentliche Snapshot QSnap wird jeweils sonntags um 00 00 Uhr erstellt Der monatliche Snapshot QSnap wird jeweils am ersten Tag des Monats um 00 00 Uhr erstellt 66 4 4 3 Rollback Die Daten aus einem Snapshot QSnap UDV k nnen auf das urspr ngliche UDV zu ruckgespielt werden Gehen Sie wie folgt vor 1 Wahlen Sie Volume Config User Data Volume Wahle
187. own issues 1 Microsoft MPIO is not supported on Windows XP or Windows 2000 Professional Workaround solution Using Windows Server 2003 or Windows 2000 server to run MPIO D Microsoft iSCSI Initiator Here is the step by step to setup Microsoft iSCSI Initiator Please visit Microsoft website for latest iSCSI initiator The following setup may not use the latest Microsoft iSCSI initiator 1 Run Microsoft iSCSI Initiator version 2 03 Please see Figure D 1 2 Click Discovery 91 erer Initiator Properties Figure D 1 3 Click Add Input IP address or DNS name of iSCSI storage device Please see Figure D 2 EF Target Portal ESCHER 2260 Figure D 2 4 Click OK Please see Figure D 3 02 iSCSI Initiator Properties Default Figure D3 5 Click Targets Please see Figure DA iSCSI Initiator Properties Figure D 4 93 6 T 8 9 Click Log On Please see Figure D 5 Check Enable multi path if running MPIO Log On to Target 2004 08 tw com gsan pec 0000000cd default target Figure D 5 Click Advance if CHAP information is needed Please see Figure D 6 Default Default LEE nepe ensure data security by providing authentication between atarger and an imitata tying to establish a connector Ta use it specii the same target EHAE secret that Was configured on the target far thts Initiator i e SEI name
188. ows Stellen Sie sicher dass die Disks vorhanden sind Dann k nnen die Disks von IOMETER auf ihre Leistung getestet werden IS Comp ute er er Manaqernent 7 Si pe Arten Yiew window Her e SS g resang Ty Computer Management Local Haun Dasz type Ric Sytem l ses Je SA Systere Took ETAY Partition Bask NIFS Heekhy 19 53 28 at Eee Partien Back FATS Heekhy 15 86 GE EJW PDO S2003 De Parttien Baski FATIZ Heeakhy oct 19 52 GE SwWindows 2000 CH Parker Basic NIFS Heekhy Svsten 19 55 66 El Ko Severs Sg opgoen ee eg Abbildung E 21 106 G Setup Anweisungen fur MPIO und MC S Es folgt schrittweise die Vorgehensweise zum Setup des MPIO Es gibt zwei Szenarien f r MPIO Es wird empfohlen das Szenario F 1 f r eine bessere Leistung zu verwen den Netzwerk Diagramm f r MPIO Read or Arc Read or Wide Read or Write OSAN F series LKAN Fams 1 Dual ports with MPIO 2 Dual ports with MPIO Direct connect host has 2 Via switches host has 2 LAN ports read or write in LAN ports read or write in one UDV one UDV Abbildung F 1 Die Setup Anweisungen sind in den folgenden Abbildungen zu sehen 1 Erstellen Sie eine VG mit RAID 5 mithilfe von 3 HDDs Volume config Volume group g No Name Total Free epp ep Status L 23 RAID cu SCH 254 Pj 7 i Online RAID 5 e i d 8 n i ee Create Delete 107 Abbildung F 2 2 Er
189. protokolls Es existieren pro Controller vier Kopien von Ereignisprotokollen da mit Benutzer in den meisten F llen das Ereignisprotokoll dann berpr fen k nnen wenn ein Diskfehler auftritt Tipps Bitte schlie en Sie eine der ersten vier Festplatten an Dann k n nen die Ereignisprotokolle gespeichert und beim n chsten Hoch fahren des Systems angezeigt werden Andernfalls gehen die Ereignisprotokolle verloren 2 3 9 ISCSIconfig Die Auswahl iSCSI Config dient zur Einstellung von Entity Property NIC Node Session und CHAP Account Entity property iSCSI entity property NIC iSCSI portal configuration Node iSCSI node configuration Session iSCSI session information CHAP account Add Remove account for iSCSI node Abbildung 3 5 1 3 5 1 Entity Property Wahlen Sie Entity Property aus um den Entity Namen des Controllers zu sehen und stellen Sie die ISNS IP f r das iSNS Internet Storage Name Service ein F gen Sie eine ISNS Server IP Adresse zu der iSNS Serverliste hinzu an welche das ISCSI Initiator Service Anfragen senden kann iSCSI config Entity property Entity name iqn 2004 08 tw com qsan p200c 000a6d016 ISNS IP Abbildung 3 5 1 1 3 5 2 NIC Wahlen Sie NIC aus um IP Adressen von iSCSI Data Ports zu ndern GEVIRAID Il verf gt Uber zwei Ports Jeden von ihnen muss einer IP Adresse im multi homed Modus zugeordnet werden au er wenn der Modus Link Aggregation
190. r R es wird auch der Fortschritt in Prozent angezeigt Nach dem Abschluss des Rebuild werden die Mar kierungen R und DG wieder entfernt Die VG ist nun vollstandig 59 Tips Listenfeld ist nicht vorhanden wenn keine VG oder nur eine VG der RAID 0 JBOD vorhanden ist Da der Benutzer f r diesen RAID Level keine dedizierte Spare Disk einstellen kann In einigen Fallen wird das Rebuild als Recover bezeichnet beide Begriffe haben die selbe Bedeutung Die folgende Tabelle zeigt die Beziehung zwischen RAID Level und Rebuild auf Disk Striping Daten werden auf mehrere Festplatten verteilt Ben tigt mindesten eine Festplatte Keine Datensicherheit pap Festplatten Spiegelung auf eine zweite Festplatte way Erweiterung des RAID Level 1 Eine Festplatte wird auf N Festplatten mirror gespiegelt RAID 3 Daten werden ber mehrere Festplatten verteilt Parit tsdaten werden auf einem dedizierten Laufwerk abgelegt Ben tigt mindestens 3 Fest platten Daten und Parit tsinformationen werden ber alle Festplatten verteilt Ben tigt mindestens drei Festplatten RAID 6 Wie RAID 5 Die Parit tsdaten sind hier doppelt vorhanden Ben tigt mindestens 4 Festplatten RAID 0 1 Spiegelung von RAID 0 Verb nden Ben tigt mindestens vier Fest platten RAID 10 Daten werden ber mehrere RAID 1 Verb nde verteilt Ben tigt min destens vier Festplatten RAID 30 Daten werden ber mehrere RAID 3 Verb nde verteil
191. r erh hten Schutz Ihrer Daten sollte Auto Shutdown ein geschalten sein F r einen erh hten Schutz und zur Vermeidung von einzelnen kurzzeitigen Phasen mit einer erh hten Temperatur die ein Auto Shutdown ausl sen verwenden die GEVIRAID Controller mehrere Richtwerte f r das automatische Shutdown Unten angef hrt finden Sie detaillierte Angaben dar ber wann das Auto Shutdown ausgel st wird 1 An den Controllern zur berpr fung der Temperatur befinden sich 3 Senso ren n mlich am Kernprozessor an der PCI X Bridge und am Tochter Board Ein GEVIRAID Controller berpr ft jeden Sensor alle 30 Sekunden Wenn ei ner der Sensoren einen Temperaturwert l nger als 3 Minuten berschritten hat wird das Auto Shutdown umgehend ausgel st 2 Die H chsttemperatur f r den Kernprozessor betr gt 85 C Die H chsttem peratur f r die PCI X Bridge betr gt 80 C Die H chsttemperatur f r das Tochter Board betr gt 80 C 3 Wenn die Hochtemperatur Phase keine 3 Minuten andauert f hrt das zu kei ner automatischen Abschaltung durch den GEVIRAID Controller 53 3 7 3 Festplatten S M A R T Unterst tzung SMART Self Monitoring Analysis and Reporting Technology ist ein Diagnose Werkzeug zur erweiterten berwachung von Festplatten und zur Meldung von zu erwartenden Defekten S M A R T gibt Benutzern die M glichkeit vor einem m glichen Festplattenfehler Ma nahmen zu ergreifen S M A R T berwacht laufend viele Attribute d
192. r gel scht Schritt 1 VG Volume Group erstellen So gehen Sie vor Name VG 5 RAID Level RAIDS RAID PD slot 1234 Selot PD e Abbildung 3 6 7 1 1 Wahlen Sie Volume Config Volume Group 2 Klicken Sie auf ZE D 3 Geben Sie einen VG Namen ein w hlen Sie ein RAID Level von der Liste und drucken Sie zur Auswahl des der RAID PD Slot s auf Selert F Bg vg u SL gt gt a Select PD Danach dr cken Sie He 2 4 berpr fen Sie das Resultat Wenn alle Einstellungen korrekt sind dr cken Sie auf D Confirm 5 Fertig Ein VG wurde erstellt Create e Delete D Kin Total Free i Crake i i No Name CB es PD UDV Status 1 2 3 RAID WG 5 Online RAID 5 E 114 114 4 0 Geseent Sie Create e Delete a Abbildung 3 6 7 2 Abbildung 3 6 7 2 Erstellung eines RAID 5 mit 4 Physical Disks benannt VG R5 Die Ge samtgr e betr gt 114 GB Da es keine UDV gibt die darauf zugreifen betr gt der freie Platz noch immer 114 GB 43 Schritt 2 Erstellen eines UDV User Data Volume So gehen Sie vor Name UDY R5 1 VG name VG 5 sl CV No Global 120 MB Capacity GB 50 Stripe height KB 64 sl Block size B 512 Read Write C write through cache Write back cache Priority High priority Middle priority Low priority lt Back e Confirm E Abbildung 3 6 7 3 1 Wahlen Sie Volume Config User Volume Group 2 Klicken Sie auf SSE
193. r the member RAID 5 volumes RAID 50 allows two hard drives fails or unplugging but at different arrays RAID 60 Striping over the member RAID 6 volumes RAID 40 allows four hard drives fails or unplugging but each two at different arrays JBOD The abbreviation of Just a Bunch Of Disks No protection of data VG fails if any hard drive fails or unplugs 4 2 VG migration and expansion To migrate the RAID level please follow the below procedures If the VG migrates to the same RAID level of the original VG it is expansion t 2 Select Volume config Volume group Decide which VG to be migrated click the button in the RAID column next the RAID level Change the RAID level by clicking the down arrow mark ae There will be a pup up which shows if the HDD is not enough to support the new setting RAID level click gt to increase hard drives then click Confirm e to go back to setup page When doing migration to lower RAID level such as the original RAID level is RAID 6 and user wants to migrate to RAID 0 the controller will evaluate this operation is safe or not and display Sure to migrate to a lower protection array to give user warning Double check the setting of RAID level and RAID PD slot If no problem click 7 Next gt gt a e Finally a confirmation page shows detail RAID info If no problem click i Confirm 7 to start migration Controller also pops up a
194. r web pages e g volume config of VG UDV CV LUN pages are similar to previous steps 41 E Select sl Free disks kW Global spares Dedicated spares a Size YG S Slot WAWN Hen See Status 1 2 Speed m gt 07100137838300 74 VG RO EE 3 056 0 aos i ER m gt 07C00137838300 74 VG RO Suhl A 3 056 a S SE e m gt 07h00137838300 74 VG RO a 3 056 n nn SR m S gt 07300137838300 74 VG RO Seh A 3 056 a S SE e i m z 2079001378a8a002 74 u a 2 DCH e SES FR D S gt 07d00137838300 74 VG R6 Boge A 3 056 e Sc 5 RD D A gt 06100137838300 74 VG R6 soon 3 056 o SES i RD D i gt 07000137838300 74 VG R6 E A 3 056 e Sc 5 RD D 5 gt 07200137838300 74 VG R6 sour 3 056 e SES S RD 10 Good Mn e gt 07200137838300 74 Grr 30Gb 11 Good e gt 07200137838300 74 VG De fips 30Gb 1 Good m gt 07400137838300 74 m Grr 30Gb 13 Good D gt 07500137838300 74 REED Grr 30Gb 14 Good m e gt 07600137838300 74 mem Grr 30Gb 15 Good D 2077001378a8a002 74 E FR 3 06b 16 Good m e gt 0f500137838300 74 mem Grr 30Gb Auto spindown Disabled E Select sl Free disks m Global soares e Dedicated spares e Figure 3 6 2 1 Figure 3 6 2 1 Physical disks of slot 1 2 3 4 are created for a VG named VG R0 Physical disks of slot 6 7 8 9 are created for a VG named VG R6 Slot 11 is set as dedicated spare disk of VG named VG R6 The others are free disks e PD column d
195. ress Gigabit 2 ports TCP IP offload IBM NetXtreme 1000 T 73P4201 PCI X Gigabit 2 ports TCP IP offload Intel PWLA8490MT PCI X Gigabit 1 port TCP IP offload Intel PWLA8492MT PCI X Gigabit 2 ports TCP IP offload Intel PWLA8494MT PCI X Gigabit 4 ports TCP IP offload GbE Switch Vendor Model aa Wee Dell PowerConnect 53240 Dell PowerConnect 27240 Dei PowerConnect 2708 o o o Hard drive P100C P120C P150C P200C support SATA I II disks Vendor Model E DEEN Hitachi Deskstar 7K250 HDS722580VLSA80 80GB 7200RPM SATA 8M a ee 7K80 HDS728080PLA380 80GB 7200RPM SA TA Il 8M Hitachi Deskstar E7K500 HDS725050KLA360 500G 7200RPM SATA II 16M NEE 7K80 HDS728040PLA320 40G 7200RPM SATA II 2M Hitachi Deskstar T7K500 HDT725032VLA360 320G 7200RPM SATA II 16M Maxtor DiamondMax Plus 9 6YO80MO 80G 7200RPM SATA 8M Maxtor DiamondMax 11 6H500F0 500G 7200RPM SATA 74 3 0Gb s 16M Samsung SpinPoint P80 HDSASP0812C 80GB 7200RPM SATA 8M 1 5Gb s 8M 1 5Gb s 8M NCQ 1 5Gb s 8M NCQ 3 0Gb s 16M NCQ 16M 3 0Gb s 16M D lt 3 0Gb s 16M 3 0Gb s 32M Caviar SE WD800JD 80GB 7200RPM SATA 3 0Gb s 8M igi Caviar SE WD1600JD 160GB 7200RPM SATA 1 5G s Raptor WD360GD 36 7GB 10000RPM SATA 1 5Gb s 8M Caviar RE2 WD4000YR 400GB 7200RPM SATA 1 5Gb s 16M NCQ RE2 WD4000YS 400GB 7200
196. rget Properties FOSANTech POC SC Disk Device Multi Path Support O54NTech Pago SCSI Disk Device Multi Path Support Figure F 20 20 Click MPIO tab select Load Balance Policy to Round Robin 118 Device Details Fail Over Only BEN El Round Robin With Subset Least Queue Depth Weighted Paths Least Blocks Ox20000 Conne Active mia FfffffFPfSa0es7c 400001 Ox20001 Conne Standby nie FFFFFFFFFS80e97c 40000 Figure F 21 21 Click Apply Device Details i Round Robin x20000 Conne Active nja FFFFFFFFFeeCeS7c 400001 Ox20001 Conpe Active nja FFFFFFFFFS80e87c 40000 Figure F 22 22 Run Device Manage in Windows Make sure MPIO device is available Then the disk can be tested performance by IOMETER 119 LS Device Manager File Action View Help 7 mBesp aA Re OA _CHRISCHOUS ER Computer Esa Disk drives Sa Ze O20hNTech PEOC SCSI Disk Device 8 h E ECG OC M ep ST3B001 385 El Display adapters E Floppy disk controllers El H Floppy disk drives Fy IDE ATAJATAPI controllers HS Keyboards e Mice and other pointing devices Monitors E Network adapters 2 d Ports COM amp LPT E Processors EE SCSI and RAID controllers cel Sound video and game controllers a System devices Universal Serial Bus controllers Figure F 23 The MC S setup instructions are very similar to MPIO detail steps are in the f
197. rheits und Vorsichtshinweise Dieses Ger t nur mit Netzspannung betreiben Nur mit der Spannung arbeiten die auf dem Typenschild angegeben ist Nehmen Sie die Anschl sse nur im spannungslosen Zustand des Ger tes vor Schlie en Sie das Ger t zuletzt an die Spannungsversorgung an Zur Vermeidung von Brandgefahr und oder elektrischem Schlag Sch tzen Sie das Ger t vor Eindringen von Feuchtigkeit oder Fremdk rpern Betreiben Sie es nur 1m angegebenen Temperaturbereich Ger t sofort vom Netz trennen bei Besch digung des Netzkabels oder Netzsteckers Eindringen von Fl ssigkeit oder Fremdk rpern Besch digung des Geh uses Reinigung des Ger tes Die Steckdose nutzen die nahe am Ger t angebracht und leicht zug nglich ist Ger t nicht ffnen Im Ger teinnern befinden sich keine Elemente die vom Benutzer eingestellt werden m ssen Geh use nicht entfernen Im Inneren dieses Ger tes befinden sich ausschlie lich wartungsfreie Bauteile berlassen Sie jegliche Reparaturen ausschlie lich qualifiziertem Fachpersonal Zur Vermeidung von Hitzestau Sorgen Sie f r gen gend Freiraum f r die r ckseitigen L ftungsausl sse des Ger tes Zur Vermeidung von schwerwiegenden Funktionsst rungen Installieren Sie zus tzliche Anwendersoftware n cht oder nur n Absprache mit der F rma GEUTEBR CK GmbH auf dem Basisger t dem Einstell oder Auswerte PC Installation und Anwendung von derartiger Software er
198. rm automatisch Wenn z B RAID 5 zerst rt wird ert nt sofort der Alarm Der Alarm verstummt automa tisch nachdem der Benutzer eine Physical Disk f r das Rebuild ge n dert hinzugef gt hat und das Rebuild erfolgt ist 2 4 3 LED Die LED Funktionen zeigen Folgendes an 1 10 Marquee Disk Status Disk Rebuilding LED Die Marquee Disk Status Disk Rebuilding LEDs werden mit denselben LEDs an gezeigt Bei verschiedenen Funktionen verhalten sich die LEDs unterschiedlich Marquee LEDs Wenn das System eingeschaltet wird und das Booten gestartet werden kann leuchtet die Marquee LED auf bis das Booten erfolgreich abgeschlossen ist Disk status LEDs Die LEDs geben den Diskstatus f r die Taskleiste an Nur beim Ein Ausschalten Disk rebuilding LEDs Wenn f r die Disks das Rebuild erfolgt blinken die LEDs Disk Access LED Von der Hardware beim Zugriff auf die Disk aktivierte LED IO Disk Power LED Die LED wird von der Hardware aktiviert wenn die Disks angeschlossen und mit Strom versorgt werden System status LED Wird verwendet um den Systemstatus anzuzeigen die LED wird eingeschaltet wenn ein Fehler auftritt oder ein RAID ausf llt Management LAN port LED GRUNE LED kennzeichnet dass das LAN sendet empf ngt ORANGE LED kenn zeichnet den 10 100 LINK des LAN Ports BUSY LED Von der Hardware aktivierte LED wenn der Front End Kanal belegt ist POWER LED Von der Hardware aktivierte LED wenn das System
199. rpr fen Sie die Detailinformationen d Volgme contig d User data volume y More Information ales m Ne Name pepj Status 1 28 a GPA ALUN coe Type VGID pane CYID phe Config DI Crente Tinn LOSLO26050 1 01 2799 Online WEHT tim 6s Bg 0 00 NORMAL 345434520 VODI 452089120 136 41 S12 1179245854 e bat e Abbildung H 9 Abbildung H 9 block size 512B fiir 64 Bit OS Einstellung Volume config User data volume More inferm ation DV amo 2 Status E SOP eum aim D Ty G TD Wi vm CN config DIE Conte Ip Mim NW GB hus 1 2 a Tupi ER ID a GB pe WG f ee Tale CN up Lo D ize Cri Time G91004574 1 UML 2799 Online WE HE I 1 64 P E D NORMAL 345494320 VOO1 452069120 135 1 005 1173347651 E Ce Rack a Abbildung H 10 Abbildung H 10 block size 4K f r 32 Bit OS Einstellung 9 LUN verbinden 125 Volume config User data volume Sach a Lreste e Caleta m Size R VG CN No Name 0 Status 1 2 SS RA ALUN en 1 uoo Gro Online fl we A HI emm i 1 Rabe 0 w n 4136 Volume config User data volume Attach SCSI ID D D LUN 0 0 Permission Read orly FRead writ Abbildung H 12 Abbildung H 12 Links P Serie Rechts S Serie LUN verbinden Schritt B Konfigurieren Sie Ihren Host Server 1 Beim S Series Controller SCSI muss der Host Server m glicherweise neu gebootet werden oder es muss SCSI HBA BIOS eingerichtet werden um Vo lumes zur Verf gung zu stell
200. rt gt Systemsteuerung gt Computerverwaltung gt Disk Management eine neue Disk wird angezeigt 128 Computer Management nn Layout Type Fle System status Capaoty Free Space Free Fault Tolerance overhead Compuber fanagement Local 21 E System Took e ics Parthion Bas FATSZ Heakty System 195266 17 013 G7 No Dk E Event Viewer E 3 Parthian Bosz FAT Heakhy Boot 1952668 162268 63 No D E Shared Folders ete Parttian Basic Healthy 9522 19 5968 00 Ma D BN Lota Users ord Groups JE iF Partikion Basic NTFS Heakhy 1808 I 9O No Cr ie agi Performance Logs and Aiert en oe 2939 2 G0 Pertkion Basic LOF Healthy 4 2068 pp 0 Na CH Devine Manager Ei Storage Removable Storage Be Disk Getragmenter Disk Plonagemenk h de Services and Apolcations mosko C E OF et 68 GE ue a FAT 19 5355 FAT3Z har rece NTFS Heokhy Svata Systemi Heakt y Boot Heekhy 2792 09 ZC Wo a3 MBIT en Sie New DIS Le eran DN Up 2933 2 6 Ae 3 20 GB LDF anire Healthy Abbildung H 17 3 Initialisieren Sie die Disk ri Fs 19 53 GE FAT32 19 53 GB FATS 536 13 03 GB NTFS Healthy System Healthy Boot Op Healthy 3 20 3 20 GS UDF Crd ree Heath Abbildung H 18 4 Konvertieren Sie in eine GPT Disk f r eine Kapazit t von mehr als 2 TB De taillierte Informationen ber GPT finden Sie unter http www microsoft com whdc device
201. s 512 MB RAM F r weitere Details siehe dazu die RAM Zertifizierungs liste in Anhang A 1 2 Terminology Das Dokument nutzt die folgenden Abk rzungen RAID ist die Abk rzung f r Redundant Array of Independent Disks Es gibt verschiedene RAID Levels die sich unter anderem im Grad der Datensicherheit der Verf gbarkeit der Daten und der Geschwindigkeit unterscheiden Eine Physical Disk ist Mitglied in einer einzigen Volu me Group Volume Group Ein Gruppe von Datentr gern Festplatten die durch einen RAID Level verbunden sind Eine VG enth lt ein oder mehrere UDV User Data Volume Jede VG muss in ein oder mehrere UDV un terteilt sein Die UDV s einer VG nutzen den selben RAID Level k nne aber in der Kapazit t unterschiedlich sein Cache Volume Das GeViRAID II nutzt den gesamten onboard Speicher als Cache Der Cache kann einzelnen UDV zugewie sen oder zur Nutzung f r alle UDV verwendet werden Die CV k nnen sich dabei f r jedes UDV in der Gr e unterscheiden LUN Logical Unit Number Eine LUN stellt das Logische Laufwerk dar das ber die SCSI Schnittstelle dem OS zur Verf gung gestellt wird Graphic User Interface Grafische Benutzeroberflache RAID width RAID width copy and row are used to describe one VG RAID copy e g RAID row 1 One 4 disk RAID 0 volume RAID width 4 RAID copy 1 RAID cell in RAID row 1 one row 2 One 3 way mirroring volume RAID width 1 RAID copy 3
202. s Clear button will clear event log Press Mute button will stop alarm if system alerts Filter e Download e Mute e Clear e INFO Yed 08 Aug 2007 16 04 25 CST UD OUICKS8809 has been created INFO Wed 08 Aug 2007 18 04 25 CST VG OUICK45427 has been created INFO Wed 08 Aug 2007 18 01 17 CST admin login from 192 168 10 121 via Web UI Figure 3 4 11 1 For customizing your own display of event logs there are total three display methods on Web Ul Console event log page popup windows on Web UI and on LCM The default setting of these three displays is WARNING and ERROR event logs enabled on Web UI and LCM The popup is default disabled Show events INFO WARNING M ERROR Pop up events INFO WARNING C ERROR Show on LCM INFO C WARNING M ERROR M lt lt Back e Confirm e Figure 3 4 11 2 The event log is displayed in reverse order which means the latest event log is on the first page The event logs are actually saved in the first four hard drives each hard drive has one copy of event log For one controller there are four copies of event logs to guarantee users can check event log most of the time when there is are failed disk s Tips Please plug in anyone of first four hard drives and then event logs can be saved and appeared in next system boot up Otherwise event logs would be gone 29 3 9 ISCSI config ISCSI config selection is for the setup of Entity Property NIC Node
203. s Manages IF security policy and starts th Started Automatic c es dite u Sa Logical Disk Manager Detects and monitors new hard disk dri Started Automatic z ST Get Weg l Sia Logical Disk Manage Configures hard disk drives and volume Manual a oe e eg elt fh i a BEINEN date E Disabled Pe Services i e eegen SE DEE EEN pw al Gu See Shado Manages software hased volume shed Manual be o ER rer Service Messenger Properties Local Computer lt a General Lon Dn Recovery Dependencies Semice name Messenger Display name Transmits net send and Alerter service messages a Description nn EES clients and servers This service is not a Path Io executable C AWINDOW S system32 evchost exe k netsves Startup type Automatic EN Service status Stopped 2 Trap Receiver Trap Source Port 162 Total Traps Received 0 Ack Sender Exit EE Mibs Load mib File qsan mib from C Tools GeViRAID QSAN SNMP MIB me CAToolsWGeViRAID I gsan mib Orgain Exploders Add the Destination Host 192 168 201 150 GeViRAID and Destination Port 162 192 168 201 150 144 Actions Add target IP Adress 192 168 201 150 GeViRAID and select Sender IP select Execute and choose C Tools failure bat for the net send function Configure Trap Receiver Ka fie Exploders Trap Data Mis zen gt Logging Miscellaneous Watch _ Va
204. sDevices Select a target and click Log On to access the storage devices for that target Click details to see information about the sessions connections and ign 2004 08 tw com qsan p120c 000a2068e d Details Refresh Ok Abbrechen ffnen Sie die Computerverwaltung console und danach die Datentr gerverwaltung Die lo gischen Laufwerke LUN s vom GeViRAID Il werden angezeigt Open the Computer Management console Expand the Storage and then click Disk Manage ment You will see logical drives LUN s from the GeViRAID Il Datentr ger 0 Basis 7453 GB Online Datentr ger 1 Basis 2000 06 GE Online A Datentrager 2 Basis 791 99 GB Online System CH 20 00 GB NTFS Fehlerfrei Systempartition Volume Ds 54 53 GB NTFS Fehlerfrei H 2000 06 GB Nicht zugeordnet 751 00 GB Nicht zugeordnet Einleitung Copyright c 2008 GEUTEBRUCK GmbH Alle Rechte vorbehalten Alle Inhalte in diesem Handbuch sind urheberrechtlich gesch tzt Die hier enthaltenen Informationen sind das Alleineigentum GEUTEBRUCK GmbH und d rfen weder komplett noch auszugsweise in Umlauf gebracht fotokopiert bersetzt auf Papier Film elektronischen Mitteln oder in maschinell lesbarer Form gebracht oder auf andere Weise reproduziert werden ohne die ausdr ckliche schriftliche Erlaubnis der GEUTEBRUCK GmbH Warenzeichen GEUTEBR CK und die in diesem Handbuch aufgef hrt
205. sable Immediate Data and enable Initial R2T qsan qai 2 Target Parameters Immediate Execution TargeilD iti Data Throttle 192 168 11 210 3260 Ta 2 e er LJ F e Figure G 3 Immediate Execution First Enable Dynamic Snack Initial R2T Data Throttle Burst 4 Click OK gangaz Target Parameters Target TargetlD 192 163 11 210 3260 Ta erm Cancel S Se 5 Click Save settings and click Yes on next page 128 SANsurfer iSCSI HBA Manager File Host View Wizard Help oO XX Connect Refresh QLOGIC iSCSI HBA 1 Port Options Port Information Target Settings Target Information Diagnostics t Host qsan qa222 7 e HBA 0 QLA4010 Pei HBA Model QLA4010 iSCSI Port Alias Name _glogic 1 gg Send targets State IP Address 192 168 11 11 HBAISCSIName qsan qa222 Greyed out entries are Potential Boot devices and cannot be modified Target Configuration a saved blank iSCSI Name will issue a SendTargets command Disable of Auto discover does not apply to SendTargets with CHAP entries Only 64 devices can be persisted bound Any changes made to devices not bound will not persist across card resets Note Right click on entry for additional features Auto bind Discovered Targets Auto discover Re discover prior SendTargets on save Enable Port iSCSI Name Target ID Alias
206. se of HDD capacity Step 1 Select Quick install then choose the RAID level to set Please refer to Figure 3 3 1 After choosing the RAID level click WE which links to another page user can set up LUN here f Quick install Stepi RAID Of 609 GB PAID 1 76 GB RAID 3 571 GB RAID 5 571 GB PAID 6 533 GB Figure 3 3 1 Step 2 Please select a LUN number Access control of host would show as a wildcard which means every host can access this volume In this page the Volume size can be changed The maximum volume size is shown To re enter the size be sure it has to be less or equal to maximum volume size Then click 7 Next gt gt E o Step 3 Confirm page Click confirm s if all setups are correct Then a page with the User data volume just been created will be shown as Figure 332 Done You can start to use the system now 22 Attach e Snapshot Create e Delete e Size R Snapshot G CN E No Mame GE Status 1 2 3 SG RAID LUN GB Oe MB 1 UICK68809 509 oun B we HI 0 00 0 00 P S _ Online RAID O 1 1 GEN QUICK45427 663 Sege A r Attach e Snapshot Create e Delete e Figure 3 3 2 Figure 3 3 2 A RAID 0 user data volume with the UDV name QUICK68809 named by the system itself with the total available volume size 609GB 3 4 System configuration System config selection is for the setup of System name
207. sion supports copy from one snapshot QSnap UDVs of the source device to the remote target device QCopy supports 2 copying tasks in the system which user can setup QCopy to 2 Snapshot QSnap UDVs for replication at the same time The target device capacity needs to be greater or equal to the source capacity The target UDV Capacity is equal or larger than the source UDV capacity To do a QCopy task please follow the below steps 1 Take snapshot QSnap on the source UDV for detail setup steps of Snapshot QSnap please refer to section 4 4 1 When setup UDV block 78 size please set 512B for the block size The QCopy now supports 512B block size only Click QCopy icon on the selected snapshot QSnap UDV Input the remote iSCSI target IP Click Next gt gt and wait for a while when webui recieves the target UDV information and corresponding LUN Select remote target LUN of the target UDV which is for QCopy Click confirm 7 then there will be a pop up window to ask user to dismount the target UDV from host server first This dismount step is to avoid any data inconsistence from others After the target UDV is dismounted from host server then click Yes for confirmation When the QCopy is processing data on the Volume config User data volume status colume there will be an indicator P for QCopy and completed percertage The source system will issue one INFO event describes the
208. snap UDV will fail 6 Snap UDV cannot be extended 4 4 2 Auto snapshot QSnap The snapshot QSnap copies can be taken manually or by schedule such as hourly or daily Please follow the procedures 1 Select Volume config User data volume 76 2 Create a snapshot QSnap space Please refer to section 4 4 1 for more detail 3 Click in Snapshot QSnap GB column to set auto snapshot QSnap 4 The auto snapshot QSnap can be set at the period of monthly weekly daily or hourly 5 Done It will take snapshots QSnap automatically Mloi Moz el oz Mloa Months to take snapshots Vlos Hos Mor Flog blog Mio Mii Miz El ai Weeks to take snapshots P fli Oa Os Oa RE D to tak hot Lan ays to take snapshots G p Osun Ummon Cltue O wed Thu Nen sat Clan oo Oot Og Clos Cos los Clos Co Hours to take snapshots Clos os Dio Mii liz Elta Elya Elts DO rs Diz O tg O to Plog F t Elo Flos lt lt Back e Confirm e Figure 4 4 2 1 Figure 4 4 2 1 It will take snapshots QSnap every month and keep the last 32 snapshot QSnap copies Tips Daily snapshot QSnap will be taken at every 00 00 Weekly Snapshot QSnap will be taken on every Sunday 00 00 Monthly snapshot QSnap will be taken on every first day of month 00 00 4 4 3 Rollback The data in snapshot QSnap UDV can rollback to original UDV Please follow the procedures yy ae 1 Select
209. spare disk e Example 1 Example 1 is to create two UDVs in one VG each UDV uses global cache volume Global cache volume is created after system boots up automatically So no action is needed to set CV Then set a global spare disk The last delete all of them Step 1 Create VG Volume Group To create the volume group please follow the procedures Name E RAID Level RAIDS sl RAID PD slot 1234 Select PO e lt lt Back e Mest gt gt e Figure 3 6 7 1 1 Select Volume config Volume group 9 Click Create ur 3 Input a VG Name choose a RAID level from the picklist press select PD to choose the RAID PD slot s then press s Next gt gt ur 4 Check the outcome Press Conim e correct 5 Done A VG has been created if all setups are Create e Delete No Name Total Free PD UDV Status Lais RAID GB GB 1 VD Online RAID 3 114 114 4 T MALL e Create e Delete Figure 3 6 7 2 Figure 3 6 7 2 Creating a RAID 5 with 4 physical disks named VG R5 The total size is 114GB Because of no related UDV there free size still remains 114GB lee Step 2 Create UDV User Data Volume To create a data user volume please follow the procedures Name UDW RS 1 VG name WUE E CH No Global 120 MB sl Capacity GB 50 Stripe height KB 64 sl Block size B Sl el Read Write Wirite through cache Write back cache Priority High priori
210. ss UDV lt name gt Global CV Ad Error Fail to adjust the size of the global cache justment Failed Info Global Cache Info The global cache is OK ee ee Failed m mer lt name gt 78 P eRe Same lt name gt oe ate eee Spare Disks cated spare disk Info Assign Disk lt slot gt to the Global Spare Disks Info UDV Read Only Info UDV lt name gt is a read only volume e E an cy lt name gt m er Policy lt name gt Info High priority UDV Info UDV lt name gt is set to high priority Mid Priority UDV Info UDV lt name gt is set to mid priority Low Priority UDV Info UDV lt name gt is set to low priority Info Info PD configuration Error PD lt slot gt Iba lt gt length lt gt config read write error lt read write gt failed a PD read write error Error PD lt gt Iba lt gt length lt gt lt read write gt error UDV recoverable Error UDV lt name gt stripe lt gt PD lt gt lba lt gt read write error length lt gt lt read write gt recoverable UDV unrecoverable Error UDV lt gt stripe lt gt PD lt gt Iba lt gt read write error length lt gt lt read write gt unrecoverable UDV stripe rewrite Info UDV lt name gt stripe lt gt rewrite column start fail succeed bitmap lt BITMAP gt lt started failed finished gt Snapshot QSnap events Description en BE Allocate Snapshot Warning Fail t
211. ssenger aktivieren Dadurch k nnen Ereignisprotokolle empfangen werden Es k nnen bis zu 3 Messenger Adressen eingegeben werden Benutzer k n nen die Ebene des Ereignisprotokolls w hlen Die beiden standardm ig aktivierten SNMP Werte f r ein Ereignisprotokoll lauten WARNING und ERROR System config Messenger Messenger IP hostname 1 Messenger IP hostname 2 Messenger IP hostname 3 Send events INFOC WARNINGIY ERROR Abbildung 3 4 9 1 3 4 10 System log server Wahlen Sie System Log Server um eine Benachrichtung via Syslog Protokoll festzu legen Der standardm ige Port des Syslogs ist 514 Benutzer k nnen auch Facility und das Event level des Protokolls auswahlen Die aktivierten Standardwerte des Er eignislevels sind INFO WARNING und ERROR system config System log server Server IP hostname Port 514 Facility Local4 sl Event level INFOM WARNINGV ERRORW Abbildung 3 4 10 1 Es gibt mehrere Syslog Server Tools Auf den folgenden Webseiten finden Sie weitere Informationen hierzu WinSyslog http www winsvslog com Kiwi Syslog Daemon http www kiwisvslog com Die meisten UNIX Systeme verf gen ber einen integrierten Syslog Daemon 26 3 4 11 Event log Unter Event Log k nnen Sie sich die Benachrichtigungen ber Ereignisse ansehen Dr cken Sie zur Auswahl des Displays die Taste Filter Durch Dr cken der Taste Download wird das gesamte Ereignisproto
212. sswort start 2 3 3 Remote control secure shell Sie ben tigen SSH Secure Shell f r den Remote Zugriff auf das GeViRAID Il SSH Client Software finden Sie unter anderem auf den folgenden Webseiten SSHWinClient WWW http www ssh com Putty WWW http www chiark greenend org uk Host Name 192 168 201 150 Login Name admin Default Passwort start 13 SW Y Tips LA GEUTEBRUCK GEVIRAID II unterst tzt nur SSH f r Remote Zugriff Um SSH zu nutzen ben tigen Sie die IP Adresse und das Passwort gt 2 4 Gehause 2 5 1 LCM Es gibt vier Tasten um das GeViRAID Il ber das LCM LCD Control Module zu be dienen A up nach oben e down nach unten ESC Escape zur ck verlassen und ENT Enter best tigen Nach dem Hochfahren des GeViRAID Il erscheint diese Anzeige GEUTEBRUCK GeVIiIRAID II Dr cken Sie ENT und scrollen Sie durch ein oder mehrmaliges Dr cken von A up and w down durch die Men s Alarm Mute Reset Shutdown Quick In stall View IP Setting Change IP Config und Reset to Default Falls bei einem Ereignis das WARNING oder ERROR Level auftritt zeigt das LCM das Ereignisprotokoll an in dem der Benutzer auch weitere Details zum Frontpanel erh lt Die folgende Tabelle beschreibt die einzelnen Funktionen Alarm Mute Schaltet bei einem Fehler den Alarm ab Reset Shutdown Neustarten oder Herunterfahren des GeViRAID II Erstellt in drei Schritten ein Volume Vie
213. st in Anhang A ob die Hardware voll unterst tzt wird Lesen Sie vor jedem Upgrade zun chst die Release Notes f r die Firmware Server Rechner mit einem SCSI HBA SCSI Kabel und Terminatoren CAT 5 CAT 5e oder CAT 6 Netzwerk Kabel f r den Management Port berlegen Sie sich ein Storage Konzept eine Speicher Konfiguration Management Port Netzwerk Informationen Wenn Sie statische IP Adressen nutzen m chten legen Sie sich eine freie IP Adresse die Subnet mask und die Adresse des Default Gateway zurecht Management und iSCSI Data Ports Netzwerkinformationen Wenn Sie statische IP Adressen nutzen m chten legen Sie sich eine freie IP Ad resse die Subnet Mask und die Adresse des Default Gateway zurecht Gigabit LAN Switches Empfohlen oder Gigabit LAN Switches mit VLAN LCAP Trunking Funktionen Optional CHAP Security Informationen einschlie lich CHAP Benutzernamen und Kenn worte Optional Stellen Sie die Hardware Verbindung ein bevor die Server und die GEVIRAID Controller hochgefahren werden Schlie en Sie zuerst das Konsolenkabel das Ma nagement Port Kabel und das iSCSI Data Port Kabel an 2 1 1 Beschreibung der Bedienelemente 2 1 2 Frontseite bei geoffneter Frontklappe 1 GeViRAID OOOO ELO EI G C ES E EEN OOOOod Zr ee AELK EE LJ L Ll L OO OO E L E L L L L L L LJ O O O O L L L L L HOTO O OOOOod wa EF KE HO GODE OOOO ENE Wal EL EI GOE ey TE EI Serie
214. stellen Sie ein UDV mithilfe der RAID 5 VG J Volume config User data volume Attach D Snapshot Create e Delete e SS Size GR H Snapshot VG CV ry No Name cB Status 1 2 3 a RAID LUM eicht name MB 1 R3 10 Onl wh Hu _ 5 0 00 0 00 a s e gt DE gen 5 Bir i4 RAIDS 0 a ng RS 100 Atat Snapshot a Create e Delete a Abbildung F 3 3 Starten Sie den Microsoft iSCSI Initiator 2 XX und berpr fen Sie den Initiator Node Namen ISCST Initiator Properties E x General Discovery Targets Persistent Targets Bound Volumes Tevices The SCS protocol uses the ng information to uniquely The SCSI the follovang identify this inkiator and authenticate targets Inkiator Node Namen an 1991 05 com miomosoft gechrischoud To rename Ihe initiator node cick Change Change To authenticate largetz using CHAP chok Secret to spec y a CHAP secret Bevel To contigure IPSec Tunnel Mode addresses chek EE mm Abbildung E A 4 Das LUN an ein R5 UDV verbinden Geben Sie in das Hostfeld den Initiator Node Namen ein 108 d Volume contig Logical unit Attach UDV RS 1068 KE Host Om 199 1 05 com microsoft deme LUN T F Permission ORead only Raad write ee Back a Confirm a Abbildung F 5 5 Die Konfigurationseinstellungen f r das Volume sind abgeschlossen volume config Logical unit Attach B Detach O Host LUN Permission UDY name Session EI qn 13991 0
215. storage GPT FAQ mspx Cc 13 55 GB FATI Abbildung H 19 5 Formatieren Sie die Disk 129 ane 0 RER 4 WD EN 0S 2909 2 G _ eb 3 20 Ge 3 20 Ge Line Abbildung H 20 6 Die Disk wurde formatiert CG 4 19 53 GB FATZ 19 53 GE FAT3Z Healthy System Healthy Book Basi Wew Volume tr er32 A7 GE 2792 87 GE NIFS Onine r Soro WE D EN Oe 20393 Gi 2 20 G 3 20 G5 UDF Onine Healthy Abbildung H 21 7 Die neue Disk ist nun bereit verf gbare Gr e 2 72 TB T My Computer Ot Alien D Fers 1b 3 8 Gr Hard we Drives Local Disk GC Local Disk 19 5 GE 17 0 GB Local Disk D Local Disk 19 5 GB 16 2 GB Local Disk E Local Disk Local Disk F Local Disk 16 0 GB 16 4 GE New V Local Disk 2 72 TB 2 72 TB iiime LH 5 314 Floppy A Spares EN 05 2939 216 CD Drive 3 20 GB D bytes Abbildung H 22 Achtung Wenn der Benutzer eine 512 B Blockgr f se f r das UDV einge richtet hat und der Host Server 32 Bit hat erscheint ein Popup dass das OS den Bereich nach 2048 GB 2 TB nicht formatie ren kann 8 Falsche Einstellungen OS kann den Bereich nach 2048GB 2TB nicht for matieren 130 Eis d cc TE Be GE 19 59 Gh FATE Online esu System Eok 1 Eet few Yobume Hi TAGE mean gas Emini Healy Abbildung H 23 System information S GEVIRAID II 131 GEUTEBRUCK GeViRAID I SCSI iSCSI GbE to SATA SAS
216. t Die verschiedenen Stati der UPS Detecting Running Unable to detect UPS Communication lost UPS reboot in progress UPS shutdown in progress Batteries failed Please change them NOW Battery Level Der aktuelle Ladezustand der UPS Batterie 3 8 System Wartung Die Funktion Maintenance erm glicht den Betrieb der Systemfunktionen wie Upgra de der aktuellsten Firmware Info um die Systemversion anzuzeigen Reset to de fault um alle Werte der Controller Konfiguration auf die urspr nglichen Einstellungen zur ckzusetzen Config Import amp Export um alle Controller Konfigurationen au er die Einstellungen VG UDV und LUN zu ex und importieren und Shutdown um das System entweder neu zu starten oder herunterzufahren 55 Upgrade Remote upload firmware Info System information Reset to default Reset to factory default Config import amp export Import export configurations Shutdown Reboot or shutdown system Abbildung 3 8 1 3 8 1 Upgrade Wahlen Sie die Funktion Upgrade wenn sie ein Upgrade der Firmware durchf hren m chten Legen Sie dazu die Datei xxxx bin mit der neuen Firmware auf der lokalen Festplatte ab Danach drucken Sie zur Auswahl der Datei auf Browse p Klicken Sie auf confirm _ Es erscheint in einem Popup Fenster die Nachricht Upgra de system now System Upgrade jetzt durchfUhren Wenn Sie ein Downgra
217. t Ben tigt min destens sechs Festplatten RAID 50 Daten werden ber mehrere RAID 5 Verb nde verteilt Ben tigt min destens sechs Festplatten RAID 60 Daten werden ber mehrere RAID 6 Verb nde verteilt Ben tigt min destens acht Festplatten JBOD Abk rzung von Just a Bunch Of Disks Ben tigt mindestens eine Festplatte 4 2 VG Migration und Erweiterung Im Folgenden sind die Schritte zur RAID level Migration beschrieben Wird das VG auf den gleichen RAID Level migriert spricht man von Erweiterung 1 Gehen Sie zu Volume Config Volume Group 2 Entscheiden Sie welche VG migriert werden soll und klicken Sie in der Spalte RAID neben dem RAID Level auf den Schalter 3 ndern Sie den RAID Level durch Anklicken des Abw rtspfeils PP 3 Zr Ein Popup erscheint und teilt mit dass nicht ausreichend Festplatten gew hlt wurden 60 um den neu eingestellten RAID Level zu unterst tzen Klicken Sie auf Jeet EDs um die Anzahl der Festplatten zu erh hen Danach kli cken Sie auf confirm um zur Setup Seite zur ckzukehren Bei ei ner Migration zu einem niedrigeren RAID Level z B der urspr ngliche RAID Le vel ist 6 und der Benutzer m chte zu RAID O migrieren bewertet der Controller ob dieser Vorgang sicher ist oder nicht und warnt den Benutzer mit der Meldung Sure to migrate to a lower protection array Sind Sie sicher dass Sie zu einem niedrigern Schutz Array migrieren m chten
218. t User Data Volume f hrt Qcopy aus R Fortschritt von Initialisierung oder Rebuild MD gt MiD Priority LO gt LOw Priority Der Schalter unterhalb des Status 2 f hrt zur Funktion Set Priority RAID Die RAID Levels die vom User Data Volume genutzt werden LUN Anzahl der LUN s die auf das Data Volume zugreifen Snapshot Der Anteil am User Date Volume der f r Snapshot QSnap zur QSnap GB Verf gung steht Der Schalter neben Snapshot QSnap ffnet die Resize Funktion zur nderung des Snapshot QSnap Platzes Der Schalter neben der Resize Funktion f hrt zur Funktion Auto Snapshot QSnap um die Frequenz der Aufnahme von Schnappsch ssen QSnap festzulegen Die Zahlen bedeuten Free Snapshot QSnap Space Total Snapshot QSnap Space Wenn ein Snapshot QSnap UDV erstellt wurde steht in dieser Spalte die Zeit der Erstellung QCopy Erstellt eine Remote Replikation VGname Der VG Name des User Data Volume CV MB Das Cache Volume des User Data Volume e UDV operations description Verbindet mit einer LUN Snapshot Wahlen Sie ein UDV zur Durchf hrung eines Snapshots QSnap 40 3 6 5 Cache volume Um den Status der Cache Volumes zu sehen wahlen Cache Volume Funktion Das Global Cache Volume ist das Default Cache Volume das beim Einschalten auto matisch erstellt wird Es kann nicht gel scht werden Die Gr e ist abh ngig von der Speicherko
219. te D Abbildung 4 5 5 Abbildung 4 5 5 QCopy kopiert gerade und der Prozentsatz der Fertigsstellung be tragt 24 69 Achtung Vor der Durchf hrung von QCopy wird empfohlen das Ziel Dateiensystem zu dismounten um inkonsistente Daten lO zu vermei den Der GEVIRAID Controller zeigt auch eine Popup Nachricht an wenn der Benutzer die QCopy Funktion ausw hlt Tips QCopy funktioniert nur mit Blockgr en von 512 MB f r sowohl die Quellen als auch die Ziel Seite Falls f r QCopy f r das Zielsystem eine Zugangskontrolle ben tigt wird wenn der Benutzer nicht m chte dass ein anderes System zu diesem Ziel UDV eine Verbindung herstellt so kann der Benutzer den Node Namen des Quellensystems f r das Ziel UDV LUN festlegen Bitte gehen Sie zum Quellensystem iSCSI Config Entity Property suchen Sie nach dem Entity Namen Node Namen und f gen Sie hinter dem Entity Namen f r die Ziel UDV LUN refinitiator 001 hinzu Der QCopy Node Name wird auch auf der Seite Volume Config User Data Volume angezeigt Z B lautet der Entity Name Node Name des Quellensystems iqn 2004 O8 tw com qsan GeViRAID II 000a0001f Dann lautet der QCopy Node Name des Quellen systems folgenderma en Der QCopy Node Name scheint auch auf der Seite Volume Config User Data Volume auf iqn 2004 08 tw com qsan p120c 000a0001f refinitiator 001 Der Benutzer ist vielleicht berrascht warum der QCopy Node Name sich vom Node Name unterscheidet
220. tication in which the authentication server sends the client a key to be used for encrypting the username and password CHAP enables the username and password to transmitting in an encrypted form for protection In P100 P120C P150C to use CHAP authentication please follow the procedures 1 Click a in Auth column 2 Select CHAP 3 Goto iSCSI config CHAP page to create account and password iSCSI contig Node Change Authentication Authentication None None Figure 3 5 3 4 Name Auth l CHAP Iqn 2004 08 tw com gsan pl150c O00383001 default target Figure 3 5 3 5 36 4 Select None to disable CHAP In P200C to use CHAP authentication please follow the procedures Click in Auth column de 2 Select CHAP 3 Goto iSCSI config CHAP page to create account and password iSCSI contig Node Change Authentication UG Authentication None Mone Figure 3 5 3 6 User a Create e Delete e u Name Auth Portal 7 all CHAP 192 168 11 227 3260 192 163 12 227 3260 Gg o o 192 168 13 227 3260 192 169 14 227 3260 1112 None m e 192 168 11 227 3260 192 169 12 227 3260 1314 None e 192 168 13 227 3260 192 158 14 227 3260 ign 2004 08 tw com gsan p200c O00s65d021 targetl None Eh Ce 192 168 11 227 32600 EE El ao lal 192 169 13 227 3260 192 168 L 22 r 2201 Leer e Create e Delete e Figure 3 5 3 7 4 Select the checkbox which enabled CHAP
221. tion failure authorization failure target not found unsupported version too many connections missing parameter session does not exist target error out of resources 11 unknown Info Error Info Error O ONO Of W Error System Overheated The system will do the auto shutdown immediately higher do the auto shutdown immediately higher lower Error Fannon exist___ Error System cooling fan is not installed Error ACloss Error AC loss for the system is detected Info LUS Detection OK _ Info UPS detection succeed Warning UPS Detection Fail_ Warning UPS detection failed Error oe Uer e a auto shutdown immediately me ITT ET Active mn E Eer Failed LAN Port Info Warning RTC Access Failed Warning Fail to access RTC dees Info Reset Password Info Reset Admin Password to default Info ResetP 2 Info Reset network settings set to default e System config events aa ee eee eee Sys Config De Info Default system configurations restored faults Restored Info Sys NVRAM OK Info The system NVRAM is active Sys NVRAM IO Error Cant access the system NVRAM Failed ft Warning Sys NVRAM is full Warning The system NVRAM is full e System maintenance events BEES Firmware Upgra Info System firmware has been upgraded ded Firmware Upgra Error System firmware upgrade failed ded Failed System reboot Info System
222. to this target UDV user can setup the node name of source system to target UDV LUN Please go to source system iSCSI config Entity property find the entity name node name and add refinitiator 001 after entity name for target UDV LUN The QCopy Node Name is also displayed in Volume config User data volume page E g the source system entity name node name is iqn 2004 08 tw com qsan p120c 000a0001f Then this source system s QCopy node name is as follows QCopy node name is also listed in Volume config User data volume page iqn 2004 08 tw com qsan p120c 000a00017f refinitiator 001 User may wonder why QCopy node name is different from the node name which user sees from host server iscsi initiator e g iqn 2004 08 tw com qsan p120c 000a0001f default target When doing QCopy the source system is acting like a host server copying its data to target system The source system is not a disk device in QCopy so the node name is different for distinguishing QCopy to disk device 4 6 Disk roaming Physical disks can be re sequenced in the same system or move whole physical disks from system 1 to system 2 This is called disk roaming Disk roaming has some constraints as described in the following 1 Check the firmware of two systems first It is better that both have same firmware version or newer 2 Whole physical disks of related VG should be moved from system 1 to system 2 together The configuration of
223. ttings Config import amp export to export and import all controller configuration except for VG UDV setting and LUN setting and Shutdown to either reboot or shutdown the system Upgrade Remote upload firmware Info System information Reset to default Reset to factory default Config import amp export Import export configurations Shutdown Reboot or shutdown system Figure 3 8 1 3 8 1 Upgrade Enter Upgrade function to upgrade firmware Please prepare new firmware file named xxxx bin in local hard drive then press 21 Jr to select the file Click confirm 7 it will pop up a message Upgrade system now If you want to downgrade to the previous FW later please export your system config first click Cancel to export system config first then click OK to start to upgrade firmware Browse the firmware to upgrade Browse Export config Confirm e Figure 3 8 1 1 65 S Uperade system now s If you want to downgrade to the previous FIN later please export your system config first Cancel Figure 3 8 1 2 When upgrading there is a progress bar running After finished upgrading the system must reboot manually Vy Tips Tg N Please contact with info geutebrueck com for latest firmware I 3 8 2 Info Enter Info function will display system information including firmware version CPU type installed system memory and controller seria
224. tual snapshot QSnap UDV data occupies 6 Attach LUN to UDV please refer to section 3 6 6 Logical unit number for more detail 7 Done It can be used as a disk Volume config User data volume Attach gt Snapshot Create o Delete o a Size SE H Snapshot VG CW No Name CB Status 1 2 3 RAID LUN GB name MB 1 UDYV RO 10 5 Awe D HI 10 00 10 00 Online rs 2 WDV R 1 13 10 OAE 1722335 C S i bom Do Ge RAIDO 0 e VG RO 100 Attach D Snapshot Create e Delete e Figure 4 4 1 1 Figure 4 4 1 1 No 1 is a RAID 0 UDV Set snapshot QSnap space to 10GB And now its space is free to snapshot QSnap No 2 is a snap UDV taken on 02 14 17 13 35 Snapshot QSnap has some constraints as the following 1 Minimum RAM size of enabling snapshot QSnap function is 512MB 2 For performance concern and future rollback the system saves Snapshot QSnap with names in sequences For example three snapshots QSnap has been taken and named snap1 first snap2 and snap3 last When deleting snap2 both of snap1 and snap2 will be deleted because snap1 are related to snap2 3 For resource concern the max number of snapshots QSnap is 32 4 If snapshot QSnap space is full controller will send a warning message about space full and the new taken snapshot QSnap will replace the oldest snapshot QSnap by rotation sequence 5 Snap UDV cannot be migrated when doing migration of related VG
225. tup 512B block size for UDV and the host server OS is 32bit in the last step of formatting disk user will find OS cannot format the area after 2048GB 2TB 8 Wrong setting result OS can not format area after 2048GB 2TB Disk 0 i Basic ic Di E F 76 60 GB 19 53 GB FAT3Z 19 53 GB FAT3Z 19 53 GB 15 09 GE NTFS Online Healthy System Healthy Boot Healthy Healthy ZEDisk 1 Basic New Volume OH 2792 99 GB 2048 00 GB NTFS 744 99 GB x OS cannot format this area Online Healthy Unallocated Sicp ROM 0 D j EN_OS 7939 7 G 3 20 GB 3 20 GB UDF Online Healthy Figure H 23 139 System information P100C P120C P150C P200C 140 I Configuration of SNMP Simple Network Management Protocol 1 Event notification Report of GeViRAID Il error messages over SNMP Example configuration GeViRAID II gt GeViScope event notification 1 1 SNMP 192 168 201 10 192 168 201 150 SCSI GeviScope GeViIRAID II 1 1 1 GeViRAID Il configuration Open the menue System config and enter the following IP Adress GeViRAID II IP Adress 192 168 201 150 GeVviRAID System config IP address oi D Gaiek Ir Skall System config System config F VW stem Mama j DHCP IP address Static Address 192 168 201 150 Mask 255 255 255 0 Gateway 192 168 201 254 DNS 127 0 D 141 SNMP configuration Select SNMP t
226. ty Middle priority Low priority lt lt Back a Confirm m Figure 3 6 7 3 1 Select Volume config User data volume 2 Click ra 3 Input a UDV name choose a VG Name and input a size to the UDV decide the stripe high block size read write mode and set priority finally click nF 4 Done A UDV has been created 5 Doone more time to create another UDV Attach e Snapshot Create e Delete e Size R Snapshot YG CN RW No Mame GE Status 1 A 3 Es RAID LUuN GB name MB 1 UDW RS 1 50 Gws BHi 0 00 0 00 Onl m 8 e e ge e r 4 RAIDS 8 e E ws 5 120 2 UDV R5 2 64 i Awe OHI 0 00 0 00 D S e d j _ 1 0 RAIDS D gt E WG 5 120 Attach e Snapshot e Create e Delete e Figure 3 6 7 4 Figure 3 6 7 4 Create UDVs named UDV R5 1 and UDV R5 2 related to VG R5 the size of UDV R5 1 is 50GB the size of UDV R5 2 is 64GB The status of these UDVs are online write back high priority with cache volume 120MB UDV R5 1 is initialing about 4 There is no LUN attached Step 3 Attach LUN to UDV 52 There are 2 methods to attach LUN to UDV 1 In Volume config User data volume press 7 Attach SB o 2 In Volume config Logical unit press E AN The procedures are as follows UDY UEW RS 1 506E Host x LUN o B Permission Read only Read write lt lt Back m Confirm e Figure 3 6 7 5 1 Select a UDV 2 Input Host
227. und die Erlaubnis dann klicken Sie auf Benutzer k nnen bis zu 256 LUNs pro System Controller verbinden Betreffend der Host Verbindung ist die Anzahl der gleichzeitigen Hosts auf 23 pro System Controller limitiert F r ein einzelnes User Data Volume UDV betr gt die Anzahl 8 was bedeutet dass 8 Hosts gleichzeitig auf dasselbe UDV zugreifen k nnen Conhnon UDV JDV 01 30GB sl Host Target qn 2004 08 tw com qsan p200c 000a6c021 targetO H LUN 0 E Permission C Read only Read write Abbildung 3 6 6 1 e LUN Operationen Verbindet eine LUN zu einem UDV Trennt eine LUN von einem UDV Zum Beispiel F r dasselbe UDV gibt es 2 Regeln eine davon ist LUN 0 die andere ist iqn hostl LUN 1 Der andere Host iqn host2 kann sich anmelden da er zur Regel 1 passt i Der Zugang wird verweigert wenn es keine Ubereinstimmung mit einer Regel gibt 42 3 6 7 Beispiele Im Folgenden einige Beispiele zur Einrichtung von Volumes In Beispiel 1 werden zwei UDV erstellt die sich das gleich CV teilen und ein Global Spare Drive eingerichtet In Beispiel 2 wer den zwei UDV erstellt Eines benutzt das Global Cache Volume das andere ein dediziertes CV Ein dediziertes Sparedrive wird eingerichtet Beispiel 1 Erstellen von 2 UDV in einer VG jedes nutzt das Global Cache Volume das beim Start automatisch erstellt wird Anschlie end wird ein globales Spare Drive erstellt Zum Schluss wird alles wiede
228. urch eine neue leere Disk ersetzt wird Dann startet das Auto Rebuild Die neue Disk wird automatisch zur Spare Disk f r die urspr ngliche VG a Wenn die neu hinzugef gte Disk nicht leer ist also andere GEVIRAID VG Infor mationen enth lt wird sie als RS Reserved gekennzeichnet und kein Auto Rebuild erfolgt b Wenn die Disk zu keiner vorhandenen VG geh rt ist sie eine FR Free Disk und das System startet die Funktion Auto Rebuild c Wenn der Benutzer die ausgefallene Disk nur entfernt und dann erneut in den selben Slot steckt startet das Auto Rebuild Durch das Rebuild derselben ausgefal lenen Disk k nnen Kundendaten jedoch sp ter aufgrund des instabilen Diskstatus besch digt werden GEUTEBR CK empfiehlt allen Kunden zum besseren Schutz der Daten nicht f r dieselbe Disk das Rebuild durchzuf hren 2 Wenn ausreichend globale Spare Disks oder dedizierte Spare Disks f r den degra dierten Array vorhanden sind startet der GEVIRAID Controller sofort das Auto Rebuild Wenn dann auf RAID 6 w hrend des Rebuilds eine weitere Disk ausf llt startet auch in diesem Fall der GEVIRAID Controller das oben beschriebene Auto Rebuild Die Funkti on Auto Rebuild funktioniert nur unter RUNTIME Bei einer Ausfallzeit funktioniert sie nicht Dadurch entsteht kein Konflikt mit der Funktion Roaming Im Modus degraded wird der Status der VG als DG angezeigt Beim Rebuild ist der Status von PD VG UDV R beim UDV ist e
229. us for the tray Only On Off situation Ill Disk rebuilding LEDs the LEDs are blinking when the disks are under rebuilding Disk Access LED Hardware activated LED when accessing disks IO Disk Power LED Hardware activated LED when the disks are plugged in and powered System status LED Used to reflect the system status by turn on the LED when error occurs or RAID malfunctioning happens Management LAN port LED GREEN LED is for LAN transmit receive indication ORANGE LED is for LAN port 10 100 LINK indication BUSY LED Hardware activated LED when the front end channel is busy POWER LED Hardware activated LED when system is powered on 18 Chapter 3 Web GUI guideline 3 1 P series GUI hierarchy The below table is the hierarchy of P series GUI System Config System name IP address Language Login config Password Date Mail SNMP Messenger System log server Event log ISCSI config Entity Property NIC Node Session CHAP account Volume config Physical disk Volume group User data Volume Cache volume Logical unit Enclosure management SES config Hardware monitor Step 1 Step 2 Step 3 Confirm System name DHCP Static Address Mask Gateway DNS HTTP port HTTPS port SSH port Language Auto logout Login lock Old password Password Confirm Time zone Date Time NTP Server Mail from address Mail to address Sent events SMTP relay SMTP ser
230. ver Authentication Account Password Confirm Send test mail SNMP trap address Community Send events Messenger IP hostname Send events Server IP hostname Port Facility Event level Filter Download Mute Clear Entity name iSNS IP Aggregation IP settings for iSCSI ports Become default gateway Set MTU P200C User Create Delete Rename Change Authentication P100C P120C P150C Change Authentication Delete P200C Create Delete Modify user information P100C P120C P150C Create Delete Free disks Global spares Dedicated spares More information Auto Spindown Create Delete More information Rename Migrate Attach Snapshot Create Delete More information Rename Extend Set read write mode Set priority Resize Snapshot space Auto Snapshot Create Delete More information Resize Attach Detach Enable Disable Auto shutdown 19 S M A R T UPS VEU a Upgrade Info Reset to default Config import amp export Shutdown 3 2 Login gt gt gt gt gt gt Only for SATA disks P100C P120C P150C UPS Type Shutdown Battery Level Shutdown Delay Shutdown UPS Browse the firmware to upgrade Export config System information Sure to reset to factory default Import Export Import file Reboot Shutdown Sure to logout P series controller supports graphic user interface GUI to operate the system B
231. volume config the current configurations will be replaced 3 8 5 Shutdown Enter Shutdown function it will display Reboot and Shutdown buttons Before power off its better to press Shutdown to flush the data from cache to physical disks The step is better for the data protection Reboot r Shutdown Figure 3 8 5 1 67 3 9 Logout For security reason Logout function will allow logout while no user is operating the system Re login the system please enter username and password again 68 Chapter 4 Advanced operation 4 1 Rebuild If one physical disk of the VG which is set as protected RAID level e g RAID 3 RAID 5 or RAID 6 is FAILED or has been unplugged removed then the VG status is changed to degraded mode the system will search detect spare disk to rebuild the degraded VG to a complete one It will detect dedicated spare disk as rebuild disk first then global spare disk GeViRAID controllers support Auto Rebuild function When the RAID level allows disk failures which the VG is protected such as RAID 3 RAID 5 RAID 6 and etc GeVIRAID controller starts Auto Rebuild as below scenario Take RAID 6 for example 1 When there is no global spare disk or dedicated spare disk on the system the controller will be in degraded mode and wait until A there is one disk assigned as spare disk or B the failed disk is removed and replaced with new clean disk then the Auto Re
232. vorbehalten Supplied subject to technical modifications and availability GEUTEBR CK GmbH Im Nassen 7 9 D 53578 Windhagen Tel 49 0 2645 137 0 Fax 999 E mail info geutebrueck com Web www geutebrueck com
233. w IP Setting Zeigt die aktuellen IP Einstellungen an Change IP Con Zum Einstellen von IP Adresse Subnet Mask und Gateway Es gibt zwei M glichkeiten DHCP IP wird von Server verge fig ben oder Static IP Reset to Default setzt das Passwort auf start und die IP Einstellungen auf einem DHCP Reset to Default IP Adresse 192 168 201 150 Default Subnet Mask 255 255 255 0 Default Gateway 192 168 201 254 19 Im Folgenden ist die LCM Men Struktur beschrieben GEVIRAID Alarm Mute AYes NOW Technology AV Reset Shutdown Shutdown es RA 3 Size zen Wies now Mow IP Seting a Static IP sans 192 168 010 050 15777 255 255 255 0 IP Gateway a Change IP DHCP Static IP IP Address Adjust IP address IP Subnet Mask Adjust Submask IP IP Gateway Adjust Gateway IP Apply IP Setting AYes NOW Reset to Default AYes NOW Achtung Bevor Sie das System ausschalten sollten Sie immer erst das Shut down Kommando ausf hren damit die Daten aus dem Cache auf die Festplatten geschrieben werden 2 4 2 System Pieper Der System Pieper hat zwei Funktionen 1 Nachdem das System erfolgreich gestartet ist piept das System f r 3 Sekun den 2 Im Fehlerfall Error level alarmiert Sie das GeVIRAID II mit einem akustischen Signal in regelm igen Abst nden solange bis entweder der Fehler beho ben wurde oder Sie den Pieper abschalten 3 Wenn der Fehler behoben wurde verstummt der Ala
234. ys on LCM user can check LCM for the IP first then open the browser and type the DHCP address The DHCP address is dynamic and user may need to check every time after reboot again When DHCP service is not available P series controllers use zero config Zeroconf to get an IP address E g on LCM 192 168 201 150 GeViRAID http 192 168 201 150 or https 192 168 201 150 https connection with encrypted Secure Sockets Layer SSL Please be aware of the https function is slower than http https is not supported on P100C 14 Click any function at the first time it will pop up a dialog to authenticate current user Login name admin Default password start 2 3 2 Console serial port Use NULL modem cable to connect console port The console setting is baud rate 115200 8 bits 1 stop bit and no parity Terminal type vt100 Login name admin Default password start 2 3 3 Remote control secure shell SSH secure shell is required for P Series controllers to remote login The SSH client software is available at the following web site SSHWinClient WWW http www ssh com Putty WWW http www chiark greenend org uk Host name 192 168 201 150 Please check your DHCP address for this field Login name admin Default password start Tips GeViRAID only support SSH for remote control For using SSH the IP address and the password is required for login 2 4 Enclosure 2 4 1 LCM Th
235. ze Adjust Volume Ze RAID 5 RAID 6 Apply The LS on Aver bei Static IP Psi BE 192 168 010 050 255 255 255 0 IP Gateway NEE DHCP AYes Nov Adjust IP IP Address See Change IP IP Subnet Adjust Submask Config Static IP Mask JP Adjust Gateway IP Gateway IP Apply IP a AYes Nov ERBEN Reset to Default 4Yes Nov as Caution Before power off it is better to execute Shutdown to flush the data from cache to physical disks 2 4 2 System buzzer The system buzzer features are describing in the following 1 The system buzzer alarms 1 second when system boots up successfully 2 The system buzzer alarms continuously when there is error level event happened The alarm will be stopped after mute 3 The alarm will be muted automatically when the error situation is resolved E g when RAID 5 is degraded and alarm rings immediately after user changes adds one physical disk for rebuilding and when the rebuilding is done the alarm will be muted automatically 2 4 3 LED The LED features are describing as follows 17 wm Marquee Disk Status Disk Rebuilding LED The Marquee Disk Status Disk Rebuilding LEDs are displayed in the same LEDs The LEDs behave for different functions in different stages Marquee LEDs When system powers on and succeeds to boot up the Marquee LED acts until the system is booting successful Il Disk status LEDs the LEDs reflect the disk stat