Home

Manual als Adobe Acrobat PDF

image

Contents

1. Every bit of the Event Status Register corresponds to one event The Bit s set when the event 1s changed and it remains set also when the event passed The ESR is cleared when the power is turned on except bit PON which 1s set and every time it is read via command ESR Or cleared with CLS Bit configuration of Event Status Register DON Power On bit 7 This event bit indicates that an off to on transition has occurred in the device s power supply URO User Request bit 6 Bit is not used and it is always 0 CME Command Error bit 5 This event bit indicates that an incorrectly formed command or query has been detected by the instrument EXE Execution Error bit 4 This event bit indicates that the received command cannot be executed owing to the device state or the command parameter being out of limits DDE Device Dependent Error bit 3 This event bit indicates that an error has occurred which is neither a Command Error a Query Error nor an Execution Error A Device specific Error is any executed device operation that has not been properly completed such as overload QYE Query Error bit 2 The bit is set f the calibrator is addressed as talker and output queue is empty or if control unit did not pick up response before sending next query OPC Operation Complete bit 0 This event bit is generated in response to the OPC command It indicates that the device has completed all selected pending operations ESE Even
2. e Schlechte Erdung und dadurch entstehende Stromschleifen Erdungspin am Netzstecker berpr fen und Doppelerdung vermeiden geerdete Ausgangsbuchse und geerdeter Pr fling e St rquellen wie magnetische und elektrische Felder in unmittelbarer N he Antennen Sender etc entfernen 29 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 10 Verifikationstest Dieser Test erm glicht die Ger teparameter zu berpr fen Ben tigte Messger te e 81 2 Digit Multimeter Type HP3458A oder Fluke 8508A oder ein anderes Ger t mit 0 01 Genauigkeit m DC Spannungsbereichen e Orbit Controls Kalibrator OCM 142 oder OCM 140 mit DC Bereichen 20V 200mADC und AC Bereich 20V 15 kHz e Widerstandsb rde ImOhm 10 mOhm 100 mOhm Burster 1280 oder anderer Typ mit 0 01 Genauigkeit e Z hler HP 53181A HO 53130 BM 642 oder anderer mit 0 001 Genauigkeit HP8903A Distortion Analyzer und Oszilloskop mit Bandbreite min 20 MHz zur Messung von THD im AC Modus Konfiguration vom Kalibrator Der Kalibrator wird ber die Frontanschl sse getestet Zum Ausschlie en von St rungen wird der Kalibrator in SETUP MENU wie folgt konfiguriert e Current Coil Coil Off e Current Sources GND GndI On Bemerkung Wenn keiner der beiden Ger te geerdet wird k nnen gro e St rsignale auftreten Generell Wenn der Kal brator an ein Messger t angeschlossen wird k nnen sich durch GND Stromschleifen gr ere St rspannungen aufbauen Die
3. Rot wird f r vom Kal brator gemessene Signale Blau wird f r Parameter oder Werte verwendet welche direkt ber die Tastatur oder ber das Menu gew hlt werden Schwarz wird f r feste Werte Beschriftung Notizen und Parametern welche nicht modifiziert werden oder f r andere feste Texte mit allgemeinen Informationen verwendet Funktion von Displaytasten wird in der untersten Sektion gezeigt Wenn die Schrift oberhalb der Taste nicht ersichtlich ist hat diese Taste im Moment keine Funktion Betriebsanleitung 10 OCM151 Stromkalibrator Orbit Controls AG 32 Ger ter ckwand Auf der R ckwand sind folgende Funktionen Multimeter Eingang Netzstecker Sicherungshalter Netzspannungsw hler Sicherung des Multimeters GPIB und RS232 Schnittstellen Erdungsanschluss und L ftungs ffnungen 1 2 3 4 5 6 Netzanschluss Netzsicherung Netzspannungswahler mit Schalter Multimeter Sicherung F315mA 250V Erdungsanschluss GPIB und RS 232 Stecker Ventilator Offnungen Multimeter Eing nge GO SON E Go EA ra 1 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 4 Bedienung 4 1 Wahl der Funktion Nach dem Einschalter f hrt der Kalibrator interne Teste aus Danach werden Referenzwerte gesetzt Funktion Source AC Strom 1A Frequenz SOHz Die Funktionen k nnen ber die Fronttasten ge ndert L Funktionswahl mit Funktionstasten Tasten SOURCE AMPLIFIER VOLTAGE oder CURRENT schalten die gew nschte Fun
4. Hz Frequenz Hz Erlaubte Abweichung Hz FREQ 1000 0 BER EE Tabelle IV Multimetertest Funktion Bereich Wert Hz Frequenz Hz Erlaubte Abweichung Tabelle V 33 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 11 Systemsteuerung Der Kal brator st mit zwei Schnittstellen ausger stet GPIB und RS232 Die Anschl sse befinden sich an der R ckwand Bei der GPIB Schnittstelle muss die richtige Adresse 0 30 bei RS232 die Geschwindigkeit 1200 bis 115200 und die Parit t eingegeben werden Der Kal brator kann zu einem gegebenen Zeitpunkt nur mit einem Datenbus arbeiten Dieser wird im Menu gew hlt 11 1 IEEE488 Data Bus ber diesen Datenbus k nnen folgende Funktionen ausgef hrt werden SH1 AH1 T5 L3 RL1 DCL SR1 Das Ger t erkennt folgende Befehle Zei DIOS DCL Device Clear reset the calibrator SDC Selected Device Clear reset the calibrator GND TW PAIR W DAV EOI End or Identify Message Terminator close the message GND TW PAIR W NRFD GND TW PAIR WINDAC GTL GoTo Local close remote control mode GND TW PAIR WI IFC D habla ieee LLO Local Lock Out local control locked DEE SPD Serial Poll Disable close serial message status SPE Serial Poll Enable release serial message status MIn A alata li fe O 0105 jn gt Ka aja NIN WIM 11 2 RS232 Serial Data Bus Jedes Wort beinhaltet 8 Bits ohne Parit t und 1 Stopp Die Geschwindigkeit ist
5. of the IEEE488 2 Status Byte register lt DNPD gt Parameter represents required value of Operational Data Enable register If query is sent calibrator returns the value of the register as a decimal number Example 64 is returned as 64 Example Set bit 1 in the Operational Data Enable register other bits are 0 STAT OPER ENAB 2 STAT OPER COND This query returns the content of Operational Condition register It is a decimal value which corresponds to the binary weighted sum of all bits in the register Register is not cleared after this query The response to the query therefore represents an instantaneous Snapshot of the register state at the time that the query was accepted Example STAT OPER COND Betriebsanleitung 44 OCH IS Stromkalibrator Orbit Controls AG STAT QUES EVEN This query returns the content of Questionable Data Event register It s a decimal value which corresponds to the binary weighted sum of all bits set in the register Register is cleared after this query Example STAT QUES EVEN STAT QUES ENAB lt DNPD gt This command enables bits in the Questionable Data Enable register Selected bits are summarized at bit 3 QSS of the IEEE488 2 Status Byte register lt DNPD gt Parameter represents required value of Questionable Data Enable register If query is sent calibrator returns the value of the registr as a decimal number Example 64 is returned as 64 Example Set bit 1 in t
6. Ausgang berlastet e Synchronisation verloren AMPLIFIER 44 SOURCE Modus Der generierte Ausgangsstrom kann zwischen 8mA und 120A gew hlt und von Ausgangsbuchsen HI und LO abgenommen werden Mit Stromspule Option 151 25 k nnen Str me bis 3000A zur Kal bration von Zangenamperemetern generiert werden Bedienung im SOURCE Modus e Mit Tastendruck SOURCE und AC oder DC Displaytasten wird der Source Modus aktiviert Das Display zeigt Stromwert an den Ausgangsbuchsen CURRENT OUTPUT HI LO Frequenz falls AC Strom gew hlt wurde Unsicherheit vom generierten Strom Betriebsanleitung 14 OCH IS Stromkalibrator Orbit Controls AG e Der Stromwert kann mit numerischen Tasten Cursor oder Potentiometer gesetzt werden Die Ausg nge sind w hrend der Wahl getrennt e Das zu kal brierende Ger t wird an die Buchsen CURRENT OUTPUT HI LO angeschlossen e Mit OPER wird der Strom an die Ausgangsbuchsen angeschlossen e Das gr ne Symbol am Display zeigt die Verbindung an e Bei Verwendung der Stromspule Option 151 25 muss diese im Hauptmenu aktiviert werden Uberlastung vom Ausgang Bei Trennung vom Pr fling oder wenn die Spannung ber die Last gr sser als spezifiziert ist werden die Ausgangsbuchsen automatische getrennt und das Display zeigt Output Overload an Die gleiche Meldung erscheint bei Verwendung von Stromspule und Frequenzen ber 80Hz Stromwahl im Modus Idc Basic und lac Basic 1 Wahl vom Strom e N
7. dem am externen Amperemeter gemessenen Wert Mit WRITE wird gespeichert c 10 kHz Frequenz e 10 kHz Kal brierpunkt wird gew hlt e Externe AC Spannung 10V bis 20V mit 10kHz Frequenz wird an METER INPUT V COM angeschlossen Der genaue Wert kann mit parallelem Standardz hler gemessen werden e Mit lt gt v A Potentiometer oder Tastatur wird der Wert eingestellt und mit WRITE gespeichert Betriebsanleitung 26 OCM151 Stromkalibrator Orbit Controls AG 8 Fehlermeldungen Bedienungsfehler werden am Display gemeldet Die Fehlerursache kann stammen durch e Nicht korrekte Bedienung wie z B Eingabe in nicht erlaubten Modus setzen von Au enbereich Werten berlasten von Ausg ngen etc e Nicht korrekte Bedienung von Schnittstellen GPIB oder RS 232 e Kal brator ist defekt Error ril Walue too large 1 435 Grd Off Frequency 54 444 Hz Coil Off Sync Int Amplitude 4 4814 l Frequencu H HAAR Hz Fehlermeldungen Fehlermeldung Beschreibung Interface Fehler falsche Befehl Datenbuffer ist berf llt Befehl wird Deadlocked A ausgef hrt Daten werden verloren Unterminated Interface Fehler Kalibrator wurde adressiert aber der Befehl nicht erhalten sd Interface Fehler Befehl empfangen aber Ausgangsbuffer beinhaltet Daten vom P vorherigen Befehl Buffer wir mit Reset oder mit Power ON gesetzt Input Buffer overrun Interface Fehler Invalid parameter Interface Fehler Unerlaubter Charakterstring o
8. operation TST This command starts the internal self test Return the self test result CO for pass or 1 for fail Betriebsanleitung 46 OCH IS Stromkalibrator Orbit Controls AG Status byte reading STB This query returns a number in range O to 255 with information about content of the register STB which carries the MSS bit status Service Request Enable SRE lt value gt This command sets conditions of the Service Request Enable register Since bit 6 s not used the maximum value is 191 Service Request Enable reading SRE This query returns the Service Request Enable Register number Event Status Register reading ESR This query returns the contents of the Event Status Register and clears the register Event Status Enable setting ESE lt value gt This command programs the Event Status Enable register bits Parameter value s number n range 0 255 Event Status Enable reading ESE This query returns the Event Status Enable register Clear status CLS This command clears the Event Status Register and the Status Byte Register except the MAV bit and output queue Output line 1s not reset 47 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG 11 4 Standard Status Data Structures Calibrator meets the standard protocol according to the standard IEEE488 2 The protocol can be used for checking of error and status behavior of the calibrator It enables single wire trans
9. or EXT according to selected synchronization mode Example OUTP SYNC INT selects frequency synchronization to internal reference OUTP SYNC Calibrator returns INT LINE or EXT OUTP SYNC LOCK lt CPD gt 0 1 This query returns the actual state of frequency synchronization e 0 output frequency is not locked it is not possible to activate the output terminals e 1 output frequency is locked to reference signal Example OUTP SYNC LOCK Calibrator returns or 0 MEASure a CONFigure subsystem This subsystem allows controlling of the internal multimeter Keyword Parameters MEASure CONFigure lt CPD gt VOL Tage CURRent MEAS This query returns value measured by the multimeter Calibrator returns the set values of amplitude and frequency using standard exponential format Example 7 456 V 50 1 Hz is returned as 7 456000e 000 5 010000e 001 Example MEAS Calibrator returns measured value 37 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG CONF lt CPD gt VOLT CURR This command sets the function of internal multimeter If query is sent calibrator returns VOLT or CURR according to selected multimeter function Example CONF VOLT sets the multimeter to function Voltage SOURce subsystem This subsystem allows controlling the individual functions of the cal brator Keyword Parameters SOURce MODE CAC ICDC I AMAC AMDC VDC VOL Tage lt DNPD gt CAC CURREent lt
10. w hlbar 1200 2400 4800 9600 19200 38400 76800 und 115200 Bd RS 232 Anschl sse 5 in e en Output ee ri mei mm 9 pin Konnektor D SUB FEMALE Kabel zwischen Kal brator und PC Konfiguration 1 1 pe Baue D Sub2_ Kalibrator Betriebsanleitung 34 OCH IS Stromkalibrator Orbit Controls AG Achtung Der Kal brator kann ber RS232 nicht gesteuert wenn nicht in Remote Modus umgeschaltet ist Befehl SYST REM oder SYST RWL muss verwendet werden 11 3 Command Syntax Die beschriebenen Befehle sind f r die beiden Schnittstellen gleich IEEE 488 und RS232 Alle Befehle sind n zwei Kolonnen aufgef hrt KEY WORD und PARAMETER KEY WORD enth lt den Namen des Befehls Der Befehl besteht aus einem oder mehreren Key Words Wenn das Key Word nicht in ist ist seine Verwendung nicht obligatorisch Gro buchstaben werden f r die abgek rzte Befehlsform verwendet Kleine Buchstaben bedeuten eine verl ngerte Befehlsform Die Parameter der Befehle sind in lt gt Die Einzelparameter sind mit Komma getrennt Parameter in m ssen nicht verwendet werden Alternative Parameter werden mit oder oder getrennt Zum Trennen von einzelnen Befehlen auf einer Programmzeile wird verwendet Beispiel CURR 100 5 OUTP ON Achtung Jeder Befehl muss mit lt cr gt oder lt lf gt abgeschlossen werden Es k nnen aber auch beide gleichzeitig lt crlf gt verwendet werden Nach dem Empfang dieses Zei
11. 8 oos 002 foo25 001 55 35 Bei Verwendung der Option 151 25 Stromspule werden 0 3 zur Ungenauigkeit addiert Der Ausgangsstrom wird mit 25 multipliziert Multimeter AC Spannung lt 1 kHz 1 20V 0 02 0 02 100 uV 20 V AC Spannung gt 1 kHz 1 20V 0 05 0 05 100 pV 20 V DC Spannung 0 20 V 0 01 0 01 100 uV 20 V 0 02 0 02 0 05 0 05 0 01 0 01 Betriebsanleitung 52 OCH IS Stromkalibrator Orbit Controls AG Allgemeine Daten Aufw rmzeit 15 m n Arbeitstemperatur 5 C 40 C Lagertemperatur 10 C 55 C Feuchtigkeit lt 90 Referenztemperatur 20 C 26 C Temperaturkoeffizient 0 1x C im Bereich 13 21 C und 25 33 C Masse B 538 mm H 283 mm T 540 mm Nettogewicht 42 kg Versorgung 115 230V 50 60 Hz Leistungsaufnahme max 2000 VA Sicherheitsklasse I gem EN 61010 53 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 13 Zubeh r OCM151 e Netzkabel Betriebsanleitung Kalibrierblatt Ersatzsicherung RS232 Kabel kuch ee NN Options auf Bestellung e 151 25 Stromspule e IEEE488 IEEE488 GPIB Kabel 2m e Caliber Software zur Kal bration von Messger ten Last update M rz 2014 ORBIT CONTROLS AG phone 41 44 730 2753 Z rcherstrasse 137 fax 41 44 730 2783 CH 8952 Schlieren Zurich info orbitcontrols ch Switzerland www orbitcontrols ch Betriebsanleitung 54
12. DC mode lt DNPD gt Parameter represents the value of the output current expressed in A If query is sent calibrator returns the value of the output voltage using standard exponential format Example 11 012 A is returned as 1 101200e 001 Example Current 23 05A CDC CURR 23 05 Note Command switches the calibrator in Current DC mode 39 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG SOUR AMAC CURR lt DNPD gt This command sets the output current value in AMAC mode lt DNPD gt Parameter represents the value of the output current expressed in If query is sent calibrator returns the value of the output current using standard exponential format Example 11 012 A is returned as 1 101200e 001 Example Current 23 05A AMAC CURR 23 05 Note Command switches the calibrator in AMAC mode SOUR AMAC FREQ lt DNPD gt This command sets the frequency in AMAC mode lt DNPD gt Parameter represents the value of frequency expressed in Hz If query is sent calibrator returns the value of the frequency using standard exponential format Example 50Hz is returned as 5 000000e 001 Example Frequency 60Hz AMAC FREQ 60 Notes Command switches the calibrator in AMAC mode SOUR AMDC CURR lt DNPD gt This command sets the output current value in AMDC mode lt DNPD gt Parameter represents the value of the output current expressed in A If query is sent calibrator returns the va
13. DNPD gt FREQuency lt DNPD gt CDC CURREent lt DNPD gt AMAC CURRent lt DNPD gt FREQuency lt DNPD gt AMDC CURRent lt DNPD gt GNU lt DNPD gt GNI lt DNPD gt STEP lt DNPD gt SOUR MODE This command returns the selected mode of the calibrator CAC CDC I AMAC AMDC e CAC Current AC mode e CDC Current DC mode e AMAC Current AC amplifier mode e AMDC Current DC amplifier mode Example MODE Betriebsanleitung 38 OCH IS Stromkalibrator Orbit Controls AG SOUR CAC CURR lt DNPD gt This command sets the output current value in Current AC mode lt DNPD gt Parameter represents the value of the output current expressed in If query is sent calibrator returns the value of the output current using standard exponential format Example 11 012 A is returned as 1 101200e 001 Example Current 23 05A CAC CURR 23 05 Note Command switches the calibrator in Current AC mode SOUR CAC FREQ lt DNPD gt This command sets the frequency in Current AC mode lt DNPD gt Parameter represents the value of frequency expressed in Hz If query 1s sent calibrator returns the value of the frequency using standard exponential format Example 50Hz is returned as 5 000000e 001 Example Frequency 60Hz CAC FREQ 60 Notes Command switches the calibrator in Current AC mode SOUR CDC CURR lt DNPD gt This command sets the output current value in Current
14. OCM151 Stromkalibrator Betriebsanleitung M151 Current Calibrator 120 000 A N Frequency 50 000 Hz 39 Sy E Amplitude 8 0818 U Frequency 0 0008 Hz ORBIT CONTROLS AG Z rcherstrasse 137 CH 8952 Schlieren Z rich Tel 41 44 730 2753 Info orbitcontrols ch www orbitcontrols ch OCH IS Stromkalibrator Orbit Controls AG INDEX I D 4 2 Vorbereutune Jur den Betrieb 5 2 1 Inhalt der SOMO UNG ini 5 2 2 Einschalten NEE 5 2 3 O A O 6 Ze Ersetzen ger SIChEruns ne 6 2 3 Sicnerheitsmabnahmen A EHRE 6 3 Kontrollelementes ssn iin 7 31 EFON Dai 7 3 2 EE EN e wani na BEN Ian 11 A E 12 EL WY ANE GOR PUK COM anita An 12 4 2 Wahl des Ausgangssienals E 13 4 3 Ein und Ausschalten der Ausg nge 000s00000000000000000s00uuu000000000000uunnnnnnnnsnnsnnnunnnnnnse 14 44 SOURCE Mod S ee 14 AS AMPLIFIER Modus ea RER 15 9 SVN CTD nasse es msn 17 Del Oe ee Er EE 17 6 setup Menu Hauptmenu AAA AA A A REE 18 OL General Meninas laos 18 6 2 Interface VICI ee 19 63 Kalbrator Men E 20 6 4 Meter VIC A AAA AAA 20 6 3 Kalbrier Medline 20 Z io 21 7 1 ASANO ATION O A T A 21 7 2 Zugang zur KallDFICrDTOZCO EEN 22 Td Wall vom E ee arial 22 1 4 NOllKkal bration aussen 25 O EehlermeldUndlOt AAA E OE EANO OE 27 CM E 28 Betriebsanleitung 2 OCH IS Stromkalibrator Orbit Controls AG IO Vena lona 30 ET A EE 34 11 1 TJTEEE455 Data BUS 34 EZ RS232 Serial Data ue 34 11 35 Command er ii
15. SYSTem subsystem The subsystem enables to control various functions from the MENU SYSTem DATE lt DNPD gt lt DNPD gt lt DNPD gt TIME lt DNPD gt lt DNPD gt lt DNPD gt ERRor REMote RWLock LOCal SYST DATE lt DNPD gt lt DNPD gt lt DNPD gt This command sets system date of the cal brator lt DNPD gt lt DNPD gt lt DNPD gt Represents date in format YYYY MM DD If query is sent calibrator returns current value of the system date in format Y YY Y MM DD where YY YY year 2000 2099 MM month 01 12 DD day 01 31 SYST TIME lt DNPD gt lt DNPD gt lt DNPD gt This command sets time of the calibrator lt DNPD gt lt DNPD gt lt DNPD gt Represents time in format HH MM Ss If query is sent calibrator returns current value of the system time in format HH MM S where HH hour 00 23 MM minute 00 59 SS second 00 59 SYST ERR Query the multimeter error queue Detected errors are placed in the queue This query returns the first error from the queue The queue is type first n first out The error 1s deleted after reading The response is in the form of String Program Data and consists of two elements a code number and an error message If all errors are read calibrator returns message 0 No Error In case of overflow the error queue the last error in the queue is 350 Queue overflow Also the earliest errors remain in the queue and the most
16. ach dem Tastendruck Select mittlere Cursortaste erscheint der Stromwert im Editiermodus grauer Hintergrund e Der Wert wir mit numerischen Tasten Cursortasten oder Potentiometer gew hlt und mit Softtasten mA oder A best tigt 2 Wahl der Frequenz f r AC Str me e Nach dem Tastendruck Select mittlere Cursortaste erscheint die Frequenz im Editiermodus grauer Hintergrund e Der Wert wir mit numerischen Tasten Cursortasten oder Potentiometer gew hlt und mit Softtaste Hz best tigt 4 5 AMPLIFIER Modus Der Kalibrator generiert Str me 8mA bis 120A entsprechend dem Signal gemessen mit internem Multimeter 15 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG Bedienung im AMPLIFIER Modus Taste AMPLIFIER wird gedr ckt und AC oder DC Modus gew hlt Das Display zeigt Stromwert an den Ausg ngen CURRENT OUTPUT HI LO Unsicherheit der Wahl Frequenz falls AC gew hlt wurde Gain vom s mulieren Verst rker Schritt Schritt 1 0 A bedeutet dass der Strom in 1A Schritten ndert x d Eingangss gnal VOLTAGE oder CURRENT mit Multimeter Tasten wird gew hlt Gain und Schritt werden gew hlt Steuersignal Spannung oder Strom zur Multimeter R ckwandanschl sse wird angeschlossen Bei Verwendung interner Synchronisation wird die Frequenz des Ausgangsstroms gew hlt Bei externer Synchronisation wird gewartet bis die Frequenz synchronisiert ist gr nes Licht neben dem Frequenzwer
17. ardmultimeter mit entsprechendem Messbereich wird an die Ausgangsbuchsen Hi und Lo angeschlossen Die Werte werden ber numerische Tastatur Cursor oder Potentiometer gew hlt Mit der Taste WRITE werden die gew hlten Werte gespeichert Mit der Softtaste EXIT werden die Eingaben ignoriert und die urspr nglichen Daten bleiben im Speicher Die Schritte m ssen f r alle Kalibrierpunkte der gew hlten Funktion wiederholt werden Mit der Softtaste EXIT werden die Eingaben ignoriert und die urspr nglichen Daten bleiben m Speicher Beenden der Kalibration Mit wiederholtem EXIT Tastendruck wird die Kalibration beendet und das Display kehrt zum Hauptmenu zur ck Kalibrierpunkte Jede Funktion hat feste Kalibrierpunkte Strom AC Nominalwert A Limiten A Bereich A Tabelle ACI 23 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG Strom DC Nominalwert A Limiten A Bereich A Tabelle DCI Multimeter Tabelle Multimeter Betriebsanleitung 24 OCH IS Stromkalibrator Orbit Controls AG 7 4 Vollkalibration Ben tigte Ger te 81 2 Digit Multimeter Type HP3458A oder Fluke 8508A oder anderer Typ mit Genauigkeit 0 001 m DC Spannungsbereich Kalibrator Orbit Controls OCM 142 oder OCM140 mit DC Bereichen 10V 20mA und AC Bereich 10V 10 kHz Widerstand Shunt 1 mQ 10 mQ 100 mQ Burster 1280 oder anderer Typ mit Genauigkeit 0 01 Z hler HP 53181A HO 53130 BM 642 oder anderer Typ mit Gen
18. auigkeit 0 001 HP8903A Distortion Analyzer und Oszilloskop mit Bandbreite mind 20 MHz werden zur THD Messung von AC S gnalen Kalibration l Kalibrator einschalten und bei 23 1 C f r 3 Std laufen lassen 2 Hauptmenu aufrufen Cal bration w hlen und SELECT dr cken 3 Kalibriercode eingeben Werkseitig 0 4 AC Stromkalibration a Aus dem Kalibriermenu Current AC w hlen und mit SELECT best tigen Am externen Multimeter die gleiche Funktion w hlen b Weitere Schritte am Display und die Tabelle ACI folgen Den Kalibrierwert gem den Werten im Messpunkten einstellen c Die Werte in den Kalibrierpunkten werden mit lt gt v Potentiometer oder numerische Tastatur eingestellt und mit WRITE best tigt Mit EXIT werden die Eingaben ignoriert d Der Widerstand Shunt wird in Bereichen 2 5 10 und 30 A verwendet falls das Standardmultimeter diese Bereiche nicht abdeckt 5 DC Current Calibration a b c Aus dem Kalibriermenu Current DC w hlen und mit SELECT best tigen Am externen Multimeter die gleiche Funktion w hlen Weitere Schritte am Display und die Tabelle DCI folgen Den Kalibrierwert gem den Werten im Messpunkten einstellen Die Werte in den Kalibrierpunkten werden mit lt gt v Potentiometer oder numerische Tastatur eingestellt und mit WRITE best tigt Mit EXIT werden die Eingaben ignoriert 23 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG d Der Wider
19. caia 35 114 Standard Status Data Structures cccscsscccssssssssssscsccssssscccccccsssscsscssssssssscsscssssssees 48 GE ER EE 52 E GE 54 3 Version 10 Operation manual OCH IS Stromkalibrator Orbit Controls AG 1 Verwendung Der Stromkalibrator OCMI51 ist eine Quelle von stabilen DC und AC Str men im Bereich von 8mA bis 120A von 15Hz bis 1000Hz Es kann zum Kalibrieren von Amperemeter Stromwandler und anderen Ger ten mit Stromeingang Interner Multimeter mit Bereichen 200mA 20V und 10kHz Frequenzeingang kann zur Simulation von programmierbarer Transkonduktanz Stromverst rkern oder als R ckmeldung vom S gnal aus Messumformern unter Test welche aus dem Kal brator getestet werde Das Ger t zeichnet sich durch Funktionen aus welche die Handhabung w hrend Betriebs vereinfachen Das gro e TFT Display zeigt die Ungenauigkeit des Ausgangssignals Ablauf von Kal brierprozeduren Status von generiertem Ausgangssignal und andere Oft verwendete Funktionen werden ber direkte Funktionstasten w hlbar Internes Menu bietet Auswahl von vorprogrammierten Parametern Ausgangsschnittstellen IEEE488 und RS232 erlauben Fernsteuerung aus einem PC Orbit Controls Kal briersoftware CALIBER steht f r automatische Kalibration zur Verf gung Betriebsanleitung 4 OCH IS Stromkalibrator Orbit Controls AG 2 Vorbereitung f r den Betrieb 2 1 Inhalt der Sendung OCM151 Stromkalibrator Netzkabel Ersatzsicherung Betriebsanl
20. chens wir die ganze Programmzeile ausgef hrt Beschreibung der Abk rzungen lt DNPD gt Decimal Numeric Program Data wird zum Einstellen des Wertes mit Hilfe einer Dezimalzahl mit oder ohne Exponent verwendet lt CPD gt Character Program Data Meistens repr sentiert durch eine Gruppe von Alternativzeichen wie z B ON IOFFIOI1 lt SPD gt String Program Data String wird zum setzen von Datum und Zeit dE Parameteranfrage Nur das Fragezeichen ist zul ssig CR Parameteranfrage Es handelt ach um einen Befehl welcher neben der Anfrage auch eine Einstellung erm glicht lt cr gt Carriage Return ASCII Zeichen 13 Ausf hrung einer Befehlszeile lt lf gt Line Feed ASCII Zeichen 10 Ausf hrung einer Befehlszeile 35 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG OUTPut subsystem This subsystem permits the activation or deactivation of the cal brator output Keyword Parameters OUTPut STATe lt CPD gt ON OFF LOWCurrent lt CPD gt FLOat GRO und CURCoil lt CPD gt OFF X25 USER USER lt DNPD gt SYNChronization lt CPD gt INT LINE IEXT LOCKed lt CPD gt 011 OUTP STAT lt CPD gt ON OFF This command activates or deactivates output terminals e ON activates the output e OFF deactivates the output If query is sent calibrator returns ON if the output is active or OFF if it is inactive Example OUTP ON activate
21. der ASCII empfangen Character data Interface Fehler Befehl enth lt ung ltiges Zeichen Interface Fehler Empfangener Befehl beinhaltet keinen g ltigen numerischen Numeric data Parameter High temperature Ausgangsstufe berhitzt Last entfernen L fter kontrollieren abk hlen lassen 746 747 748 Slave error Fehler interner Kommunikation 27 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 9 Wartung Der Kalibrator ist ein von Mikroprozessor kontrolliertes elektronisches Ger t Die Leistungsbl cke werden von Ventilatoren gek hlt F r korrekte Arbeitsweise muss folgendes beachtet werden Bitte beachten OCM151 ist ein Laborger t e Zum Ein und Ausschalten nur den Schalter an der Front ben tzen e Nicht an andere Versorgung anschlie en als der Netzw hler zeigt e Ventilator ffnungen vorne und hinten nicht zudecken e Nicht in staubiger Umgebung betreiben e Fl ssigkeit oder kleine Objekte nicht hineinfallen lassen e Nicht au erhalb des spezifizierten Temperaturbereichs verwenden e Das zu testende Ger t an die korrekten Buchsen anschlie en Der Kal brator kann mit Fremdsignalen besch digt werden e Korrekte Kabeldicke verwenden Ausgangsbuchsen nicht besch digen e Wo immer m glich Ausgang LO immer auf GND im Menu setzen Gndl On e Mit angeschlossener Last n cht unn tig lange einschalten lassen e Kabel verwenden welche dem Strom entsprechen Regul re Pflege Es wird keine spez
22. eitung Kalibrierblatt RS232 Anschlusskabel Der Kalibrator wird aus dem Netz 230 115 V 50 60 Hz versorgt Er ist ein Laborger t mit Parametern welche bei Labortemperatur 23 3 C garantiert sind Die Ventilatoren an der Front und der R ckseite d rfen nicht zugedeckt werden 2 2 Einschalten Vor Einschalten bitte die Wahl der Netzversorgung am Spannungsw hler auf der R ckseite kontrollieren Netzkabel in den Ger testecker einf hren nachher den Netzstecker in die Steckdose stecken Mit dem Netzschalter an der R ckwand wird das Ger t eingeschaltet Das Display erleuchtet W hrend ca 5 Sek wird die interne Hardware automatisch getestet Am Ende vom Test werden Referenzparameter gesetzt Function AC current Current range LA Set value LA Frequency 50 Hz Output terminals OFF Die GPIB Adresse ist im Werk auf 2 eingestellt kann beliebig anders gew hlt werden Notiz Nach jedem Neueinschalten werden die Referenzparameter gesetzt 5 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 2 3 Aufw rmzeit Die spezifizierten Parameter werden erst nach 60 Minuten gew hrt W hrend der Aufw rmzeit ist der Kal brator voll funktionsf hig die Eigenkalibration kann aber nicht durchgef hrt werden 2 4 Ersetzen der Sicherung Die Sicherung befindet sich im Ger te Netzstecker Defekte Sicherung wird wie folgt ersetzt e Kal brator ausschalten e Netzkabel ausstecken e Sicherungshalter herausnehmen defekte Sic
23. ervice bit 6 The bit is read as a part of status byte only when serial message is sent MSS Master Summary Status bit 6 The MSS bit is set to 1 whenever bits ESB or MAV are 1 and enabled 1 in the SRE This bit can be read using the STB command His value is derived from STB and SRE status ESB Event Summary Bit bit 5 His value is derived from STB and SRE status The ESB bit s set to when one or more enabled ESR bits are set to 1 MAV Message Available bit 4 The MAV bit is set to 1 whenever data is available in the IEEE488 Output Queue the response on query is ready QSS Questionable Summary Status bit 3 SCPI defined The QSS bit is set to 1 when the data in the QSR Questionable Status Register contains one or more enabled bits which are true SRE Service Request Enable Register The Service Request Enable Register suppresses or allows the STB bits 0 value of a SRE bit means that the bit does not influence value of MSS bit Value of any unmasks STB bit results in setting of the MSS bit to the level 1 SRE bit 6 1s not influenced and its value 1s 0 The SRE register value can be set via the command SRE followed by mask register value 0 191 The register can be read with the command SRE The register is automatically resets after switching the calibrator on The register is not reset by the command CLS 49 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG ESR Event Status Register
24. he Questionable Data Enable register other bits are 0 STAT QUES ENAB 2 STAT QUES COND This query returns the content of Questionable Condition register It s a decimal value which corresponds to the binary weighted sum of all bits in the register Register is not cleared after this query The response to the query therefore represents an instantaneous Snapshot of the register state at the time that the query was accepted Example STAT QUES COND STAT PRES This command clears all bits in the Operation Data Enable register and in the Questionable Data Enable register Example STAT PRES 45 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG IEEE488 2 Common Commands I D instrument identification IDN This command returns the identification of the manufacturer model serial number and firmware revision The reply is formatted as follows ORBIT M151 510001 1 22 other customized name can be factory set Operation complete OPC This command sets the OPC bit in the ESR Event Status Register when all pending operations are complete Operation complete OPC This command returns 1 to the output queue after all pending operations are complete Wait to Continue command WA This command prevents the instrument from executing any further commande or queries until all previous remote commands have been executed Reset RST This command resets the calibrator to 1ts initial status Test
25. herung durch neue mit gleicher Stromgr e ersetzen 2 5 Sicherheitsmafnahmen Der Kalibrator entspricht Sicherheitsklasse I gem EN 61010 1 und ber cksichtigt A2 Nachtrag Die Sicherheit st durch Verwendung von spezifischen Komponenten gew hrt Der Hersteller st n cht haftbar f r Sch den welche durch Modifikationen oder Verwendung von nicht originalen Teilen entstehen w rden Sicherheitssymbole Achtung Warnung elektrischer Schock Betriebsanleitung 6 OCM151 Stromkalibrator Orbit Controls AG 3 Kontrollelemente 3 1 Frontpanel Die Ger tefront beinhaltet das Display Taster und Ausgangsbuchsen LA 9 1 2 MER urrent Calibrator 120 000 A VY sm Y o Frequency 58 808 Hz Amplitude 8 0018 U 5 Frequency 0 0009 Hz 7 1 Cursortasten Uber die Cursortasten kann der Kalibrator innerhalb der spezifizierten Grenzen bedient werden Mit Keyboard Tasten lt gt kann der Cursor in die verlangte Lage am Display positioniert werden Diese Tasten werden meistens zum Rollen durch die Optionen w hlen zwischen Optionen oder schalten zwischen Menu Ebenen Die Zentraltaste wird zur Best tigung der Wahl verwendet TAB 2 Potentiometer Wird verwendet f r e Schalten zwischen Optionen e Eingabe der numerischen Werte Das Potentiometer kann auch als Cursor verwendet werden Die Zentraltaste wird zur Best tigung der Wahl oder zum umschalten der Potentiometer Funktion Wert oder Posi
26. hren Abweichungen d rfen die Toleranzen nicht berschreiten Stromeingang vom Multimeter mit externem Stromkal brator verbinden DC Stromwerte gem Tabelle V w hlen Multimeter Test im Bereich 200mA DC nach Tabelle CV durchf hren Abweichungen d rfen die Toleranzen nicht berschreiten Kalibratorausgang mit 100mOhm Shunt belasten und an Distortion Meter anschlie en Ausgangsstrom 1AAC 1000Hz w hlen Harmonische Verzerrung messen Sie darf nicht 0 05 berschreiten Wenn die Werte in einem oder mehreren Testpunkten au erhalb der Toleranzen liegen muss die entsprechende Funktion und Bereich neu kalibriert werden Es ist nicht n tig alle Funktionen neu zu kal brieren 31 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG Limiten 1A DC Grundbereich mit Linearit tstest Funktion Bereich Wert A Frequenz Hz Erlaubte Abweichung HA 200 D ADO O 1A BE 2928 _ CC ADC JA 06 ADO IA O O Il AA ADC JA 1 D ll 200 E el BET Sur EEE Y O E SE RENE EE ADC JA 1 04 ll 200 ADO IA O 2B Il 298 _ ADC JA 06 ADO IA ID Il ABI ADC JA 1 08 ll 200 CC ADC JA LI 08 ls Tabelle DC Stromtest Tabelle I AC Stromtest IO I Bere Wert HA Frequenz Hz Erlaubte Abweichung HA 300 0 mA DE EN ZEN A _ 600 120 0 A 120 0 Tabelle Il Betriebsanleitung 32 OCH IS Stromkalibrator Orbit Controls AG Frequenztest Funktion Bereich Wert
27. ielle Pflege ben tigt Das Geh use kann mit feuchtem Tuch gereinigt werden Elektrische Teile ben tigen keine Pflege oder Reinigung Der Kalibrator sollte im 12 monatigen Intervall geeicht werden Betriebsanleitung 28 OCH IS Stromkalibrator Orbit Controls AG Was zu tun ist wenn Fehler angezeigt wird Sichtbare Fehler wie z B eine nicht leuchtende Anzeige oder nicht drehende Ventilatoren haben ihre Ursache n der Ger teversorgung Die Sicherung muss berpr ft werden Diese befindet s ch im Ger testecker an der R ckwand Sie wird wie folgt ersetzt e Kalibrator ausschalten Netzkabel herausziehen e Mit einem spitzigen Gegenstand Schraubenzieher den Sicherungshalter ffnen und die Sicherung herausnehmen e Defekte Sicherung ersetzen e Den Sicherungshalter schlie en Netzkabel einstecken und Ger t einschalten Wird der Fehler dadurch nicht behoben muss der Hersteller oder der Landesvertreter kontaktiert werden Bei einer nicht korrekten Funktion eines oder mehrerer Bereiche oder S gnale muss der Hersteller oder der Landesvertreter kontaktiert werden Unsichtbare Fehler manifestieren sich meistens mit Unstabilit t Temperaturdrift S gnalverzerrung Isolationsverlust etc In solchen F llen muss der Hersteller oder der Landesvertreter kontaktiert werden Es k nnen aber auch Fehler auftreten welche auf nicht korrekte Handhabung zur ckzuf hren sind wie z B e Versorgung au er Toleranzen oder unstabiles Netz
28. it und Datum Interface Parameter der Schnittstellen Calibrator Signalparameter Meter Parameter vom Multimeter Calibration Kalibrierdaten 6 1 General Menu Parameter vom Display und der Tastatur 1 Volume Piepser Lautst rke 1st zwischen O bis 15 mit Kursortasten Potentiometer oder Tastatur w hlbar Mit Write Softtaste wird gespeichert 2 Brightness Anzeigehelligkeit wird zwischen O und 7 mit Cursortasten Potentiometer oder numerischen Tasten gew hlt Mit Write Softtaste wird gespeichert Betriebsanleitung 18 OCH IS Stromkalibrator Orbit Controls AG 3 Beeper Piepser Ein oder Aus kann mit Potentiometer gew hlt werden 4 Kalibration Passwort Um Kalibriermodus zu aktivieren muss eine f nfstellige Zahl eingegeben werden Wird die Zahl 0 sein so wird sie in Menu angezeigt Andere Kombinationen werden als Secret gekennzeichnet Das Passwort wird ber numerische Tastatur eingegeben und mit ENTER best tigt Es kann auch mit Potentiometer oder Cursortasten zwischen 0 und 99999 ge ndert werden Mit WRITE wird es gespeichert 5 Time Die Zeit kann mit numerischer Tastatur Potentiometer oder Cursortasten eingestellt werden 6 Date Das Datum kann mit numerischer Tastatur Potentiometer oder Cursortasten eingestellt werden 7 Information Ger te Serie Nummer und Softwareversion 6 2 Interface Menu Das Submenu beinhaltet die Schnittstellenparameter 1 Active interface Wahl der Steueru
29. ktion ein W hrend der Wahl wir der Kalibrator in STANDBY Modus umgeschaltet und die Ausgangsbuchsen abgetrennt 2 Ein und Ausschalten der Ausgangsbuchsen Mit der Taste OPER werden die Ausgangsbuchsen ein und ausgeschaltet 3 Wahl AC DC Mit der Taste AC DC wird der Modus des Stromausgangs AC oder DC gew hlt 4 Zugang zum Hauptmenu Mit der Softtaste SETUP wird das Hauptmenu er ffnet Das Menu erlaubt die Basiseinstellung und den Zugang zum Kalibriermodus Mit der Softtaste EXIT wird die vorherige Funktion geschaltet Betriebsanleitung 12 OCM151 Stromkalibrator Orbit Controls AG 4 2 Wahl des Ausgangssignals Bearbeitungsmodus Parameter des Ausgangss gnals blaue Displayfarbe k nnen m Editiermodus gew hlt werden Das Display wird in den Editiermodus geschaltet mit Numerischen Tasten select Taste Mittlere Cursortaste Cursor Tasten Potentiometer Im Editiermodus ist der Wert im blauen Hintergrund dargestellt Mit Select wird der Parameter best tigt Softtaste Exit beendet die Wahl Wahl mit numerischen Tasten e Nach der Eingabe vom ersten Digit erscheint das Eingabefeld Die obere Reihe zeigt den Parameternamen Mit der Softtaste kann neuer Wert eingegeben werden e Mit Enter wird die Eingabe beendet F r Basiseinheiten A Hz stehen die Tasten Source AC 1 00000 HM as Grd Off Frequency op opp DE Coil Off Sync Int Input value Frequency 100 z
30. lle Position vom Cursor WA falls der Parameter im Editiermodus ist Die Position vom Cursor kann mit lt gt ge ndert werden Der Parameter wird mit A v oder mit Potentiometer ver ndert 2 Hilfsparameter Hilfsparameter der gew hlten Funktion e Frequenz AC e Verst rkung Gain in Amplifier mode e Schritt Step in Amplifier mode 3 Ausgangsstufe Zustand der Ausgangsbuchsen geschaltet oder offen Symbole im Fenster OFF Ausgange getrennt HA Ausg nge geschaltet 9 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 4 Spezifikationen Spezifikationen des Ausgangssignals Die Unsicherheit ist auf den Hauptwert bezogen BUSY wird gezeigt anstelle der Genauigkeit wenn der Wert nicht innerhalb der spezifizierten Parametern ist oder wenn die interne Korrektur gerechnet wird Dies passiert w hrend Wechseln der Funktion Wahl von Parametern oder Ein und Ausschalten der Ausgangsbuchsen Informationssektion Diese befindet sich im rechten Fenster und zeigt zus tzliche Informationen zur gew hlten Funktion e Endungsmethode der Ausgangsbuchsen GND wird im Menu Calibrator gew hlt e Information zur Verwendung einer Stromspule im Menu Calibrator e Information zur Synchronisation nur beim AC Ausgang C Messgerat Informationsfeld D Display Softtasten softkeys Diese Tasten haben diverse Funktionen welche vom aktuellen Displaymodus abh ngen Displayfarben Display colors 1 2
31. lue of the output current using standard exponential format Example 11 012 A is returned as 1 101200e 001 Example Current 23 05A AMDC CURR 23 05 Note Command switches the calibrator in AMDC mode Betriebsanleitung 40 OCH IS Stromkalibrator Orbit Controls AG SOUR GNU lt DNPD gt This command sets the gain value in transconductance amplifier mode AMAC and AMDC lt DNPD gt Parameter represents the value of the gain expressed in A V If query is sent calibrator returns the value of the output current using standard exponential format Example 5 123 A V is returned as 5 123000e 000 Example Gain 8 05 A V GNU 8 05 SOUR GNI lt DNPD gt This command sets the gain value in current amplifier mode AMAC and AMDC lt DNPD gt Parameter represents the value of the gain expressed in A A If query is sent calibrator returns the value of the output current using standard exponential format Example 612 A A is returned as 6 120000e 002 Example Gain 600 A A GNI 600 SOUR STEP lt DNPD gt This command sets the output current step value in AMAC and AMDC mode lt DNPD gt Parameter represents the value of the output current step expressed in A If query is sent calibrator returns the value of the output current using standard exponential format Example 0 5 A is returned as 5 000000e 001 Example Step 0 5 A STEP 0 5 41 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG
32. mitting of SRQ command The conditions on which SRQ signal local control request is sent can be set with parameters STB SRE SRE ESR ESE ESE a CLS PON ura cme exe ooe ave o forc ESR Event Status Register Read using ESR Output Queue Read using ESE Write using ESR ESE Event Status Enable Register QSS Summary Bit not used Read by Serial Poll STB Status Byte Register Read using STB Read using SRE Write using SRE SRE Service Request Enable Register Status Register Overview Status data structure contains following registers STB Status Byte Register SRE Service Request Enable Register ESR Event Status Register ESE Event Status Enable Register Output Queue Betriebsanleitung 48 OCH IS Stromkalibrator Orbit Controls AG STB Status Byte Register STB is main register where information from other status registers and from the output queue is collected Value of STB register s reset after switching on the calibrator or after sending command CTS This command reset the STB register except bit MAV which remains set if the output queue is not empty STB register value can be read via serial message or through general query STB Bit configuration of Status Byte Register OSS Operation Summary Status bit 7 SCPI defined The OSS bit s set to 1 when the data in the OSR Operation Status Register contains one or more enabled bits which are true RQS Request S
33. ng IEEE488 RS232 oder Ethernet 2 IEEE488 address Die EEE488 GPIB Adresse kann zwischen O und 30 mit numerischer Tastatur Potentiometer oder Cursortasten eingestellt werden Werkeinstellung ist 02 3 Baud rate Baud Rate von RS232 1200 2400 4800 9600 19200 38400 76800 oder 115200 Bd 19 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG 6 3 Kalibrator Menu Das Menu beinhaltet Parameter des generierten Signals 1 Current output Lo GND Die LO Strombuchse kann mit GND verbunden werden Wahl Gnd Off oder Gnd On Es wird empfohlen LO Anschluss auf GND zu legen Wenn das Ger t unter Test hat den Lo Anschluss auf GND wird im Menu GND OFF gew hlt um eine eventuelle Stromschleiche auszuschlie en ANCHTUNG Wenn weder Kalibrator noch das getestete Ger t nicht mit GND verbunden sind kann das Rauschen am Stromausgang h here Werte erreichen als spezifiziert 2 Current coil Optionale Stromschleife mit 25 Windungen kann zur Kal bration von Stromzangen bis 3000A verwendet werden Im Menu wird der Parameter Coil Off Coil x25 und Coil user type aktiviert 3 Coil user multiplier Die Anzahl von Windungen kann zwischen 10 und 50 gew hlt und mit Write best tigt werden 4 Synchronisation Synchronisation des Ausgangss gnals kann gew hlt werden Internal interne Synchronisation Power Line Synchronisation aus der Netzversorgung oder External Synchronisation zum Multimeter Eingang Notiz Externe Synchroni
34. ombereiche und beide Polarit ten und durchgef hrt Multimeter Meter wird f r 20V 200mA und 10 kHz kalibriert 21 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG 7 2 Zugang zur Kalibrierprozedur Main menu Setup General Interface Calibrator Meter Calibration Enter Password Mit Passwort ist der Zugang zum Kalibriermenu m glich Taste MENU dr cken Kalibration Submenu w hlen und Softtaste Select dr cken Passwort wird verlang Passwort eingeben und mit ENTER best tigen Beim falsche Passwort erscheint Bad calibration code 7 3 Wahl vom Kalibrierung Einer der Punkte kann mit Cursortasten A v gew hlt und mit Select best tigt werden Beispiel ist f r AC Strom gezeigt Current HI Current HI AHHuH ar high LC 2HHml 1Hac 1Hac Hac Hac SAAC SAAC low A 3A Range 3HHmAac low L3HmHA i high 1A low 1A E 329378181 high 5A lHAac low CH lBAac high 161 126Aac low 1 148A 124Aac high 1 38H 12HAac low 2 148A G Write Die Softtaste haben folgende Funktionen Write Neuer Wert wird gespeichert alter Wert geht verloren Skip Neuer Wert wird nicht angenommen alter bleibt gespeichert Das Display zeigt den kalibrierten Bereich Range 300mAac und den Wert welcher am externen Standard Multimeter gew hlt werden soll 30mA Betriebsanleitung 22 OCH IS Stromkalibrator Orbit Controls AG Wahl neuer Kalibrierdaten Ein Stand
35. recent error s discarded Example SYST ERR Betriebsanleitung 42 OCH IS Stromkalibrator Orbit Controls AG SYST REM This command sets the calibrator into the remote mode operation with RS232 All keys on the front panel except the LOCAL key are disabled Note It is not possible to send or receive data over RS232 when the calibrator is not in the remote mode SYST RWL This command places the calibrator into the remote mode for RS232 operation All keys on the front panel including the LOCAL key are disabled SYST LOC This command returns the calibrator n the local mode This command s for RS232 43 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG STATus subsystem This subsystem is used to enable bits in the Operation and Questionable Event registers The Operation and Questionable Event Enable and Condition registers can be interrogated to determine their state STATus OPERational EVENt ENABle lt DNPD gt CON Dition QUEStionable EVENt ENABle lt DNPD gt CONDition PRESet STAT OPER EVEN This query returns the content of Operational Data Event register It is a decimal value which corresponds to the binary weighted sum of all bits set in the register Register is cleared after this query Example STAT OPER EVEN STAT OPER ENAB lt DNPD gt This command enables bits in the Operational Data Enable register Selected bits are summarized at bit 7 OSS
36. s the output OUTP the calibrator returns ON or OFF OUTP LOWC lt CPD gt FLO GRO This command connects disconnects the Lo current output terminal to from the GND e FLO ungrounds current output e GRO grounds current output If query is sent calibrator returns GRO when the output is grounded or FLO when floating Example OUTP LOWC GRO OUTP LOWC Calibrator returns FLO or GRO OUTP CURC lt CPD gt OFF X25 USER This command activates or deactivates the use of 25 turns current coil or the user current coil e OFF deactivates the current coil e X25 activates the 25 turns current coil e USER activates the user current coil If query is sent calibrator returns USER if the user coil is activated X25 if the 25 turn coil is activated or OFF if the current coil is deactivated Example OUTP CURC X25 activates 25 turn current coil OUTP CURC Calibrator returns OFF USER or X25 Betriebsanleitung 36 OCH IS Stromkalibrator Orbit Controls AG OUTP CURC USER lt DNPD gt This command sets the number of the turns lt DNPD gt Parameter represents the number of the turns Example OUTP CURC USER 50 sets the 50 turn current coil OUTP SYNC lt CPD gt INT LINE EXT This command sets mode of output frequency synchronization e INT internal synchronization e LINE synchronization to power supply frequency e EXT synchronization to external signal If query is sent calibrator returns INT LINE
37. sation hat gr ere Verzerrung als interne 6 4 Meter Menu Das Menu beinhaltet Parameter vom Multimeter 1 Function Die Funktion kann f r AC DC Spannung 0 20V und AC DC Strom 0 200mA gesetzt werden Das Display zeigt auch die Frequenz des gemessenen S gnals 6 5 Kalibrier Menu Ein Passwort wird ben tigt in das Kalibriermenu zu gelangen Werkeinstellung ist O0 Betriebsanleitung 20 OCH IS Stromkalibrator Orbit Controls AG 7 Kalibriermodus Neukalibration wird ber die Tastatur durchgef hrt 7 1 Kalibration Das Ger t kann kalibriert werden e Volle Kal bration Alle Funktionen in allen empfohlenen Punkten e Teilkal bration Gew hlte Funktion in allen empfohlenen Punkten e Teilkal bration Gew hlte Funktion in gew hlten Punkten Die komplette Kalibration beinhaltet alle Teilkalibrationen vom Kalibriermenu Im gew hlter Kalibrierschritt z B Current AC m ssen nicht alle Bereiche kalibriert werden Wenn Kalibration von alle Bereichen nicht m glich ist k nnen die alten Daten bernommen und die Kal bration beendet werden Kalibration kann in jeden Punkt beendet werden Dieser Punkt kann aber einen Einfluss auf die gesamten Spezifikationen haben Die Genauigkeit ist nur dann gew hrleistet wenn vollst ndige Kalibration durchgef hrt wird AC Stromkalibration wird in zwei festen Punkten f r alle Strombereiche bei 55Hz durchgef hrt DC Stromkalibration wird in zwei festen Punkten f r alle Str
38. se k nnen die Genauigkeit stark beeinflussen vor allem durch starkes Rauschen Kurzzeitstabilit t oder Nichtharmonische Verzerrung Es soll der Lo Stromausgang nur auf einer Seite geerdet werden Zur Behebung k nnen auch Toroidspulen verwendet werden Der Verifikationstest kann erst dann gestartet werden wenn der Kalibrator mind eine Stunde eingeschaltet ist bevor er mind 8 Std in der Laborumgebung gestanden ist Betriebsanleitung 30 OCH IS Stromkalibrator Orbit Controls AG Testschritte 1 A DC Strom mit Linearit tstest DC Strom Test von internen Bereichen 300mA 2 A 5 A 10 A 30 A 60 A 120 A AC Strom Test von internen Bereichen 300mA 2 A 5 A 10 A 30 A 60 A 120 A Frequenztest bei 1kHz Multimetertest von internen Bereichen 20VDC 200mADC Frequenz 10kHz Die Testschritte sind gem Tabelle weiter l Za 3 10 11 Kalibrator mind 1 Std eingeschaltet bei 23 1 C laufen lassen Standardmultimeter und den Kal brator anschlie en 1A DC Emearit tstest ausf hren DC Strom AC Strom gem Tabellen I H IM Abweichungen d rfen die Toleranzen nicht berschreiten Ausgang mit 100mOhm Shunt belasten 1A AC und 1kHz w hlen Frequenztest gem Tabelle IV ausf hren Abweichungen d rfen die Toleranzen nicht berschreiten Spannungs Multimetereingang mit externem Kalibrator verbinden Frequenz und DC Spannung gem Tabelle V w hlen Multimeter Test im Punkt FREQUENCY 10000Hz und 20VDC durchf
39. stand Shunt wird n Bereichen 2 5 10 und 30 A verwendet falls das Standardmultimeter diese Bereiche nicht abdeckt 6 Kalibration vom Multimeter Die Kal bration beinhaltet Eichung von 20 V 200 mA und 10kHz Orbit Controls OCM142 Kalibrator wird verwendet Falls nicht erh ltlich wird em 81 2 stelliges Multimeter benutzt a 20 V DC e Meter im Kalibriermenu wird gew hlt Mit Softtaste SELECT wir der erste Punkt OV gew hlt e Eing nge METER INPUT V COM vom Multimeter werden kurzgeschlossen e Das Display zeigt den Wert 0 000 wird mit Write gespeichert e 20V Messpunkt wird gew hlt e Externe Spannung von 20V DC wird a METER INPUT V COM angelegt Die exakte Spannung kann mit externem Standard Multimeter gemessen e Am Display wird der exakte Wert mit lt gt v A Potentiometer oder Tastatur eingestellt Der Wert entspricht dem am externen Multimeter gemessenen Wert Mit WRITE wird gespeichert b 20mA DC e Meter im Kalibriermenu wird gew hlt Mit Softtaste SELECT wir der erste Punkt OmA gew hlt e Eing nge METER INPUT V COM vom Multimeter werden kurzgeschlossen e Das Display zeigt den Wert 0 000 wird mit Write gespeichert e 200mA Kal brierpunkt w hlen e Externer Strom von 200V DC wird a METER INPUT mA COM angelegt Der exakte Strom kann mit externem Standard Amperemeter gemessen e Am Display wird der exakte Wert mit lt gt v A Potentiometer oder Tastatur eingestellt Der Wert entspricht
40. t Das zu testende Ger t wird an die Ausg nge CURRENT OUTPUT HI LO angeschlossen Taste OPER wird gedr ckt Gr nes Symbol zeigt die Verbindung der Stromausg nge Bei Verwendung einer Stromspule wird diese im Menu aktiviert Betriebsanleitung 16 OCH IS Stromkalibrator Orbit Controls AG 5 Multimeter Das interne Multimeter ist zur Messung externer AC DC Spannungen und Str me sowie Frequenzen bestimmt Die Eing nge befinden sich an der R ckwand Die Anschl sse mA und COM sind f r die Strommessung V und COM sind f r Spannung und Freuquenzmessung 5 1 Funktionswahl e Die Messfunktion wird im Menu Meter oder mit VOLTAGE CURRENT Tasten gew hlt e Mit Displaytasten UP DOWN oder mit Potentiometer wir die Funktion gew hlt Voltage AC Spannung 20 V 15 10000 Hz DC Spannung 20 V Current AC Strom 200 mA 15 10000 Hz DC Strom 200mA 17 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG 6 Setup Menu Hauptmenu Das Setup Menu wird f r wenig ben tzen Parameter verwendet Das Menu wird mit der Softtaste SETUP er ffnet Main menu Setup Interface Calibrator Meter Calibration Das Menu wird mit A v Cursor oder Potentiometer auf dem Display gerollt Die gew nschte Position wird mit SELECT oder mit dem Potentiometer gew hlt Mit EXIT wird das Menu verlassen Die Wahl bleibt auch beim Ausschalten gespeichert Das Menu beinhaltet General allgemeine Einstellungen Display Tasten Ze
41. t Status Enable Register The Event Status Enable Register allows one or more events in the Event Status Register to be reflected in the ESB summary message bit This register s defined for 8 bits each corresponding to the bits in the Event Status Register The Event Status Enable Register is read with the common query ESE Data is returned as a binary weighted value The Event Status Enable Register is written by the common command ESE Sending the ESE common command followed by a zero Clears the ESE The Event Status Enable Register is cleared upon power on It suppresses or allows bits in ESR register Value 0 of a bit of ESE register suppresses influence of appropriate bit of ESR register on value of sum bit of ESB status register Setting of any unmask bit of ESR register results in setting of ESB status register ESE register value can be modified by command ESE followed by value of mask register integer in range 0 255 Reading of the register can be performed with command ESE The register is automatically reset after switching on The register is not reset with CLS command Operation Status Register Not used in the calibrator Questionable Status Register Not used in the calibrator Betriebsanleitung 50 OCH IS Stromkalibrator Orbit Controls AG Output Queue The Output Queue stores response messages until they are read from control unit If there is at minimum one sign in the output queue MAV register message a
42. tion Wahl 7 Betriebsanleitung OCH IS Stromkalibrator Orbit Controls AG 3 Numerische Tastatur Mit den numerischen Tastatur werden die Werte gew hlt mit ENTER best tigt und mit CANCEL annulliert Funktionstasten Diese haben folgende Funktionen Funktion Taste Source mode SOURCE Amplifier mode AMPLIFIER Voltage measurement VOLTAGE Current measurement CURRENT Output Operate Standby OPER 4 Ein Aus Schalter ON OFF Switch Mit diesem Schalter wird die Netzversorgung Ein und Ausgeschaltet 5 Lufteinzug Air inlet Lufteinzug f r die K hlung 6 Stromausgang Current output Ausgangsstrom Abschliisse HI und LO 7 Displaytasten Display Keys F nf Tasten unter dem Display haben mehrere Funktionen abh ngig vom momentanen Displayinhalt Meistens rufen sie die local Menu units modes usw auf Betriebsanleitung 8 OCM151 Stromkalibrator Orbit Controls AG 8 Display A Ene l B1 gt 1 00000 A D 3 7 BA B2 mk Frequency 5A 0AA ee Sync Int m B5 Input meter C wech Amplitude D po1p U Frequency H HAA D Das Display ist in drei horizontalen Sektionen unterteilt A Obere Informationszeile e Gew hlte Funktion Source AC e Datum und Zeit e Steuerfunktion Local Tasten Remote PC Steuerung B Hauptfeld In dieser Sektion werden die generierten Signale sowie die Daten zum Kalibrierstatus dargestellt 1 Hauptwert Stromwert mit Zeichen AC oder DC aktue
43. ur Verf gung e Der Kalibrator ist zur Ausgabe des neuen Werts vorbereitet e Der Wert wird n das entsprechende Feld am Display kopiert und das Eingabefeld geschlossen Wahl mit Cursortasten e Tasten lt gt A oder v werden verwendet Der Cursor markiert die zu ndernde aktive Stelle e Mit A und v wird die Ziffer gew hlt mit lt gt die Position vom Cursor e Mit Exit kehrt das Display zum vorherigen Zustand 13 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG Wahl mit Potentiometer e Mit dem Potentiometer wird der Cursor positioniert e Wird der Knopf gedr ckt erscheinen Symbole und oberhalb der Ziffer und diese kann durch das Drehen vom Potentiometer ge ndert werden e Mit Exit wird zum vorherigen Display zur ckgekehrt Bemerkung Alle Parameter s nd innerhalb von spezifizierten Limiten Maximum und Minimum w hlbar Bei einer Wahl au erhalb von Limiten wird eine Fehlmeldung angezeigt Value too large small und der Wert wird nicht angenommen 4 3 Ein und Ausschalten der Ausg nge Beim Einschalten des Ger ts sind die Ausg nge immer ausgeschaltet Die taste OPER schaltet den gew hlten Strom an die Ausgangsbuchsen und die Verbindung wird mit dem Symbol EEE am Display signalisiert Mit der Taste OPER wird der Ausgang getrennt Das Symbol auf dem Display zeigt Der Strom wird von den Ausgangsbuchsen automatisch getrennt wenn e Funktion wird ge ndert e
44. vailable is set The Output Queue is cleared upon power on and after reading all signs from output queue Error Queue The Error Queue stores error messages They are placed in a first in first out queue The queue is read destructively using the query command SYSTem ERRor to obtain a code number and error message The query SYSTem ERRor can be used to read errors in the queue until it is empty when the message 0 No Error will be returned 51 Betriebsanleitung OCM151 Stromkalibrator Orbit Controls AG 12 Technische Daten Die angegebenen Daten sind erst g ltig wenn der Kal brator mind 60 Minuten bei einer Raumtemperatur von 23 2 C eingeschaltet st Die Spezifikationen enthalten die Langzeitstabilitat Temperaturkoeffizient Lastcharakteristiken Netzunstabilit t sowie die Anbindung an den Nationalstandard Die Spezifikationen sind 12 Monate g ltig DC AC Strom Sinusf rmig Gesamtbereich 8 mA bis 120 A Stromaufl sung 5 2 Digits Frequenzbereich DC 15 Hz bis 1000 Hz Frequenzgenauigkeit 0 005 Frequenzaufl sung 0 001 Hz unter 500 Hz 0 01 Hz unter 1000 Hz Verzerrung lt 0 1 Isolation der Ausgange bis 450 Vp p gegen GND Schutzerde Wert Max Wert DC 15 40 Hz 40 70 Hz 15 400 400 1000 70 1000 Hz Hz Hz 0 008000 0 300000 A 0 025 0 01 8 0 03 0 02 0 025 0 01 0 30001 1 00000A 0 025 0 01 8 0 03 0 02 0 025 0 01 1 00001 2 00000A 0 025 0 01