1. HARVIA XENIO CD Control unit U DE Steuerger t 09072015 ZVR 841 These instructions for installation and use are intended for owners of saunas heaters and control units persons in charge of managing saunas heaters and control units and for electricians responsible for installing heaters and control units Once the control unit is installed these instructions of installation and use are handed over to the owner of the sauna heater and control unit or to the person in charge of maintaining them CONTROL UNIT HARVIA XENIO CX170 Control unit s purpose of use the control unit is meant for controlling the functions of a sauna heater It is not to be used for any other purpose Congratulations on making an excellent choice CONTENTS 1 HARVIA XENIO ee 3 1 1 General 1 2 Technical Data 1 3 Troubleshooting 2 INSTRUCTIONS FOR USE ninnenennnnenanne 2 1 Using the Heater r keni usaram nee 2 1 1 Heater On 2 1 2 Heater OfF 2 2 Changing the Settings 2 3 Using Accessories 2 3 1 Lighting En 23 2 VEntilation rss ae re rag age 3 INSTRUCTIONS FOR INSTALLATION 9 3 1 Installing the Control Panel 3 2 Installing the Power Unit 3 2 1 Electrical Connections 3 2 2 Power Unit Fuse Faults j 3 2 3 Power extension unit LTY17 optional 12 3
2. Press the MENU button to access the next setting Gehen Sie zur n chsten Einstellung ber indem Sie die MENU Taste dr cken Memory for power failures The memory for power failures can be turned ON or OFF e When turned on the system will start again after a break in electricity When turned off the break will shut the system down I O button must be pressed to restart The safety regulations for memory usage vary from region to region Speicher f r Stromausf lle Der Speicher f r Stromausf lle kann ein oder ausgeschaltet werden ON oder OFF e Durch das Einschalten wird das System nach einem Stromausfall neu gestartet e Durch das Abschalten wird das System heruntergefahren Fur einen Neustart muss die I O Taste gedr ckt werden e Die Sicherheitsvorschriften f r die Verwendung des Speichers k nnen je nach Region variieren Press the MENU button to access the next setting Gehen Sie zur n chsten Einstellung ber indem Sie die MENU Taste dr cken SEEY OFF Im U MIL LI FI 4 45 Sauna dehumidifying in progress Entfeuchtung der Sauna l uft Sauna dehumidifying interval The sauna dehumidifying interval can be turned ON or OFF The interval will begin when the devices are switched off from the I O buttons or when the set on time runs out During the interval e the heater is on e the sauna room temperature is set at 40 C e If a fan is conne
3. nie an der Seite des Ofens 3 3 2 Montage des Temperaturf hlers WX325 wahlweise Bringen Sie den Temperaturf hler so weit wie m g lich vom Ofen entfernt an der Wand an in einem Abstand von 500 700 mm zur Decke Siehe Abb 7 und 8 Permitted area for WX325 i Zul ssiger Bereich f r WX325 min 500 mm max 700 mm TI WX325 i Temperature sensor optional Temperaturf hler wahlweise WX232 Temperature sensor Temperaturf hler WX232 1100 mm ASS ges RS Figure 7 The place of the temperature sensors in connection with wall mounted heaters Abbildung 7 Position der Temperaturf hler bei fen mit Wandbefestigung 12 EN DE WX325 f r WX325 Permitted area for Zulassiger Bereich WX325 j Temperature i sensor optional Temperaturf hler wahlweise WX232 Tempera ture sensor Temperatur f hler in 500 mm max 700 mm m Figure 8 Abbildung 8 Heater A min A max Ofen mm mm BC105 50 150 BC135 80 180 BC165 100 200 F10 5 ae ten kio 19 F15 F16 5 150 250 K11G 70 170 T7 100 130 T9 120 150 T10 5 150 180 PO11 100 200 PO165 150 300 PI7OE PISOE 100 100 PC7OE PC9OE 100 100 PC7OHE PC9OHE 30 100 PC110E 100 100 PC110HE 30 100 HL70
4. 3 Installing the Temperature Sensors 12 3 3 1 Installing the Temperature Sensor WX232 12 3 3 2 Installing the Temperature Sensor WX325 OPTION All miil kisama a ui KULA 3 4 Resetting the Overheat Protector 4 SPARE PARTS nranennnnnnnanannnnannnnanann annan 14 Diese Montage und Gebrauchsanleitung richtet sich an Besitzer von Saunen Ofen und Steuerger ten an Personen die f r den Betrieb von Saunen Ofen und Steuerger ten verantwortlich sind sowie an Elektromonteure die mit der Montage von Sau na fen und Steuerger ten betraut sind Nach der Montage des Steuerger ts ist diese Montage und Gebrauchsanleitung dem Besitzer der Sauna des Ofens bzw des Steuerger ts oder der f r die War tung der Anlagen zust ndigen Person auszuh ndi gen STEUERGER T HARVIA XENIO CX170 Verwendungszweck des Steuerger ts Das Steuerger t dient zur Steuerung der Funktionen eines Saunaofens Er darf nicht f r andere Zwecke verwendet werden Wir begl ckw nschen Sie zu Ihrer guten Wahl INHALT T HARVIA XENIO 2 32 2 maad ern 1 1 Allgemeines 1 2 Technische Daten 1 3 St rungsbeseitigung 2 BEDIENUNGSANLEITUNG ninnnnnanenennnne 2 1 Verwendung des Ofens nnnnnnrnnnnnnnnnna 2 1 1 Ofen einschalten 2 1 2 Ofen ausschalten 2 2 ndern der Einstellungen 2 3 Verwendung des Zub
5. when the control unit is in standby mode ADDITIONAL SETTINGS WEITERE EINSTELLUNGEN Standby des Steuerger ts Die Kontrollleuchte der I O Taste leuchtet auf dem Bedienfeld ffnen Sie das Einstellungsmen indem Sie gleichzeitig die Taste MENU und dr cken siehe Abb 2 Halten Sie die Tasten 5 Sekunden lang gedr ckt Im Standbye Modus leuchten die Tasten nicht Maximum on time The maximum on time can be changed with the and buttons The range is 1 12 hours 6 hours Maximale Einschaltzeit Die maximale Einschaltzeit kann mit den Ta sten und ge ndert werden Der Einstellbe reich betr gt 1 bis 12 Stunden 6 Stunden Example the heater will be on for 6 hours from the start Remaining on time can be changed see figure 3a Beispiel Der Saunaofen wird von Beginn an 6 Stunden lang laufen Die verbleibende Einschalt zeit kann ge ndert werden siehe Abb 3a Press the MENU button to access the next setting Sensor reading adjustment The reading can be corrected by 10 units The adjustment does not affect the measured temperature value directly but changes the measuring curve Gehen Sie zur n chsten Einstellung ber indem Sie die MENU Taste dr cken Einstellung des F hlerwerts Die Messwerte k nnen um 10 Einheiten korrigiert werden Die Einstellung betrifft nicht den gemessenen Temperaturwert direkt sondern ndert die Messkurve
6. HL90 HL110 30 150 HL135 50 150 HL160 80 150 The place of the temperature sensors in connection with floor mounted heaters Position der Temperaturf hler bei Freistehende fen kl SS Figure 9 Abbildung 9 Sensor s minimum distance from an air vent Mindestabstand des F hlers zu Luftschlitzen 13 EN 3 4 Resetting the Overheat Protector The sensor box WX232 contains a temperature sensor and an overheat protector If the temperature in the sensor s environment rises too high the overheat protector cuts off the heater power Resetting the overheat protector is shown in figure 10 Note The reason for the going off must be deter mined before the button is pressed DE 3 4 Zur ckstellen der Uberhitzungsschutzes Das F hlergeh use WX232 enth lt einen Tempe raturf hler und einen berhitzungsschutz Wenn die Temperatur in der Umgebung des Temperatur f hlers zu stark ansteigt unterbricht der Uberhit zungsschutz die Stromzufuhr Das Zur cksetzen des berhitzungsschutzes wird in Abbildung 10 dargstellt Achtung Bevor Sie den Knopf dr cken m ssen Sie die Ursache f r die Ausl sung des berhit zungsschutzes ermitteln Figure 10 Reset button of the overheat protector Abbildung 10 R ckstellknopf des berhitzungsschutzes 4 SPARE PARTS 4 ERSATZTEILE 1 Contro
7. Leistungseinheit Data cable Datakabel Sauna room Saunakabine Temperature sensor WX232 Temperaturf hler WX232 Temperature sensor WX325 optional Temperaturf hler WX325 wahlweise Heater Ofen i i switch Hauptschalter EN 1 3 Troubleshooting If an error occurs the heater power will cut off and the control panel will show an error message E number which helps troubleshooting the cause for the error Table 1 Note All service operations must be done by pro fessional maintenance personnel No user service DE 1 3 St rungsbeseitigung Wenn eine St rung auftritt wird der Ofen abge schaltet und auf dem Bedienfeld wird eine Fehler meldung im Format E Nummer angezeigt die Hilfe bei der St rungsbeseitigung bietet Tabelle 1 Achtung Alle WartungsmaBnahmen m ssen von technisch qualifiziertem Personal durchgef hrt wer den Es befinden sich keine vom Benutzer zu war able parts inside tenden Teile im Ger t Description Beschreibung Remedy Abhilfe E1 Temperature sensor s measuring Check the red and yellow wires to the temperature sensor and their circuit broken connections see figure 6 for faulties Messkreis des Temperaturf hlers Pr fen Sie die roten und gelben Kabel zum Temperaturf hler und deren unterbrochen Verbindungen siehe Abb 6 auf Fehler E2 Temperature sensor s measur
8. aximum on time Temperature Einschaltzeit berschritten ist Die 71 117 indicator light switches off Pre setting Temperaturkontrollleuchte erlischt Das LI ELI time symbol blinks on the screen Symbol f r die Vorwahlzeit blinkt auf der SN e Select the desired pre setting time using Anzeige PD s the and buttons The time changes e W hlen Sie mit den Tasten und die in 10 minute steps gew nschte Vorwahlzeit aus Die Zeit kann in 10 Minuten Schritten ge ndert werden Example the heater will start after 10 Beispiel Der Saunaofen wird in 10 Minuten minutes eingeschaltet ME Press the MENU button to exit Dr cken Sie die MENU Taste um die Einstellungen zu beenden Basic mode pre setting time running Basis Modus Vorwahlzeit l uft Ofen aus heater off Die sich verringernde Vorwahlzeit wird bis zum The decrease of remaining pre setting time Stand von null angezeigt und anschlie end wird is shown until zero appears after which the der Ofen eingeschaltet heater is switched on Figure 3a Settings menu structure basic settings Abbildung 3a Struktur des Einstellungsmen s Grundeinstellungen EN Control unit standby I O button s background light glows on the control panel DE Open the settings menu by simultaneously pressing the locations of the buttons MENU and see figure 2 Press for 5 seconds The buttons do not glow
9. cted to the control unit it will also be on The length of the interval is 45 minutes When the time runs out the devices turn off automatically The interval can also be stopped manually at any time by press ing the I O button Dehumidifying helps to keep your sauna in a good condition Entfeuchtungsintervall der Sauna Das Entfeuchtungsintervall der Sauna kann ein oder ausgeschaltet werden ON oder OFF Das Intervall beginnt wenn die Gerate ber die I O Tasten ausgeschaltet werden oder wenn die eingestellte Einschaltzeit abgelaufen ist Wahrend des Intervalls e ist der Ofen an e betragt die Temperatur der Saunakabine 40 C e wird eine am Steuergerat angebrachte Bel ftung ebenfalls aktiviert Die Lange des Intervalls betragt 45 Minuten Nach Ablauf der Zeit werden die Gerate automa tisch ausgeschaltet Das Intervall l sst sich auch jederzeit manuell durch Dr cken der I O Taste unterbrechen Die Entfeuchtung dient dazu Ihre Sauna in einem guten Zustand zu halten MEN Press the MENU button The control unit switches to standby mode Dr cken Sie die MENU Taste Das Steuerger t schaltet in den Standby Modus um Figure 3b Settings menu structure additional settings Abbildung 3b Struktur des Einstellungsmen s weitere Einstellungen 8 Factory setting Werkseinstellung EN 3 INSTRUCTIONS FOR INSTALLATION The electrical connections of the control unit may only be made by an authorise
10. d professional electrician and in accordance with the current regulations When the installation of the control unit is complete the person in charge of the installation must pass on to the user the instructions for installation and use that come with the control unit and must give the user the necessary training for using the heater and the control unit 3 1 Installing the Control Panel The control panel is splashproof and has a small operating voltage The panel can be installed in the washing or dressing room or in the living quarters If the panel is installed in the sauna room it must DE 3 INSTALLATIONSANLEITUNG Die elektrischen Anschl sse des Steuerger ts d r fen nur von einem autorisierten geschulten Elektri ker unter Beachtung der aktuell g ltigen Vorschrif ten vorgenommen werden Nach der Installation des Steuerger ts ist der verantwortliche Monteur verpflichtet dem Benutzer die mitgelieferte Installa tions und Bedienungsanleitung auszuh ndigen und der Person die den Ofen und das Steuerger t be dient eine entsprechende Schulung zu geben 3 1 Montage des Bedienfelds Das Bedienfeld ist spritzwassergesch tzt und hat eine niedrige Betriebsspannung Das Bedienfeld kann im Wasch Umkleide oder Wohnraum mon tiert werden Wird das Bedienteil der Steuerung in Thread the data cable through the hole in the back cover Fasten the back cover to a wall with screWs Push the data cable to the c
11. e Temperatur w hrend die untere Zeile f nf Sekunden lang die Einschaltzeit anzeigt Sobald die gew nschte Temperatur in der Sau nakabine erreicht wurde werden die Heizelemente automatisch ausgeschaltet Um die gew nschte Temperatur beizubehalten schaltet das Steuerge r t die Heizelemente in regelm igen Zeitabst n den ein und aus Bei einer angemessenen Ofenleistung und einer korrekt eingebauten Sauna ist diese innerhalb von einer Stunde aufgeheizt 2 1 2 Ofen ausschalten Der Ofen wird ausgeschaltet und das Steuerger t schaltet in den Standby Modus um wenn e die I O Taste gedr ckt wird e die eingestellte Einschaltzeit abl uft oder e ein Fehler auftritt ACHTUNG Pr fen Sie unbedingt ob die Strom versorgung zum Saunaofen getrennt ist nachdem 5 EN has elapsed the dehumidification has ended or the heater has been switched off manually 2 2 Changing the Settings The settings menu structure and changing the settings is shown in figures 3a and 3b The programmed temperature value and all values of additional settings are stored in memory and will also apply when the device is switched on next time 2 3 Using Accessories Lighting and ventilation can be started and shut down separately from other functions 2 3 1 Lighting The lighting of the sauna room can be set up so that it can be controlled from the control panel Max 100 W NUR IS Switch the lights on off by pressing the control panel butt
12. e figures 7 and 8 DE 3 2 3 Optionale Leistungseinheit LTY 17 wahlweise Die maximale Belastung der Steuereinheit kann mit zusatzlicher Leistungseinheit LTY17 um 17 kW er h ht werden Die zus tzliche Leistungseinheit ent halt detaillierte Anweisungen der Installation 3 3 Montage des Temperaturf hlers Achtung Der Temperaturf hler darf nicht n her als 1000 mm an einen Mehrrichtungs Luftschlitz oder naher als 500 mm an einen Luftschlitz angebracht werden der vom F hler wegzeigt Siehe Abbildung 9 Der Luftzug in der Nahe von Luftschlitzen k hlt den Fuhler ab was zu ungenauen Temperaturmes sungen am Steuerger t f hrt Dies kann zu einer Uberhitzung des Ofens f hren 3 3 1 Montage des Temperaturf hlers WX232 Uberpr fen Sie den richtigen Standort des Tempe raturf hlers nach den Gebrauchs und Montagean leitungen des Ofens Ofen mit Wandbefestigung Abbildung 7 e Bringen Sie den Temperaturf hler ber dem Ofen an der Wand an an der vertikalen Mittel linie die parallel an den Seiten des Ofens ver l uft in einem Abstand von 100 mm zur Decke Freistehende fen Abbildung 8 e Option 1 Bringen Sie den Temperaturf hler ber dem Ofen an der Wand an an der vertikalen Mit tellinie die parallel an den Seiten des Ofens ver l uft in einem Abstand von 100 mm zur Decke e Option 2 Bringen Sie den Temperaturf hler Uber dem Ofen an der Decke an in einem Ab stand von 100 200 mm zur vertikalen Mittelli
13. ed by 17 kW by using power extension unit LTY17 The power extension unit includes detailed instruc tions of installation 3 3 Installing the Temperature Sensors Note Do not install the temperature sensor closer than 1000 mm to an omnidirectional air vent or closer than 500 mm to an air vent directed away from the sensor See figure 9 The air flow near an air vent cools down the sensor which gives inac curate temperature readings to the control unit As a result the heater might overheat 3 3 1 Installing the Temperature Sensor WX232 Check the correct location for the temperature sen sor from the heater s instructions for installation and use Wall mounted heaters see figure 7 e Fasten the temperature sensor on the wall above the heater along the vertical centre line running parallel to the sides of the heater at a distance of 100 mm from the ceiling Floor mounted heaters see figure 8 e Option 1 Fasten the temperature sensor on the wall above the heater along the vertical centre line running parallel to the sides of the heater at a distance of 100 mm from the ceiling e Option 2 Fasten the temperature sensor to the ceiling above the heater at a distance of 100 200 mm from the vertical centre line of the heater s side 3 3 2 Installing the Temperature Sensor WX325 optional Fasten the temperature sensor on the wall as far from the heater as possible and at a distance of 500 700 mm from the ceiling Se
14. eh rs 2 3 1 Beleuchtung ae 23 2 BEUNO iee tenan ee a aan A beams tee 3 INSTALLATIONSANLEITUNG ninnnennnne 3 1 Montage des Bedienfelds 3 2 Montage der Leistungseinheit fee 3 2 1 Elektrische Anschl sse n 3 2 2 Sicherungsdefekte der Leistungseinheit 10 3 2 3 Optionale Leistungseinheit LTY17 wahlweise 12 3 3 Montage des Temperaturf hlers 12 3 3 1 Montage des Temperaturf hlers WX232 12 3 3 2 Montage des Temperaturf hlers WX325 wahlweise SL EESEL EE PATEE SGR EE 12 3 4 Zur ckstellen der berhitzungsschutzes 14 4 ERSATZTEILE 15 u 22cm 14 EN 1 HARVIA XENIO 1 1 General The purpose of Harvia Xenio control unit is to con trol an electric sauna heater within an output range of 2 3 17 kW The control unit consists of a con trol panel a power unit and a temperature sensor See figure 1 The control unit regulates the temperature in the sauna room based on information given by the sen sor The temperature sensor and the overheat protec tor are located in the temperature sensor box The temperature is sensed by an NTC thermistor and the overheat protector can be reset gt 3 4 An additional sensor is available as an option By using two sensors it is possible to acquire more ac curate temperature readings from the sauna room The control
15. eh use des Temperaturf hlers Die Temperatur wird mit einem NTC Thermistor erfasst und der Uberhitzungs schutz ist r cksetzbar gt 3 4 Ein weiterer F hler ist als Zubeh r erh ltlich Durch die Verwendung von zwei F hlern ist es m glich genauere Temperaturmessungen in der Saunakabine vorzunehmen Mit dem Steuerger t l sst sich der Start des Ofens voreinstellen Vorwahlzeit Siehe Abbildung 3a 1 2 Technische Daten Bedienfeld e Temperatur Einstellbereich 40 110 C e Betriebszeit Einstellbereich Familiensaunen 1 6 h ffentliche Saunen in Apartmentgeb u den 1 12 h Zu l ngeren Betriebszeiten befra gen Sie bitte den Importeur bzw Hersteller Einstellbare Vorwahlzeit O 12 h Steuerung von Beleuchtung und Bel ftung Abmessungen 85 mm x 24 mm x 110 mm Datakabel L nge 5 Meter kann mit 10 m Ver l ngerungskabeln bis 30 m verl ngert werden Leistungseinheit e Versorgungsspannung 400 V 3N e Max Last 17 kW e Beleuchtungssteuerung max Leistung 100 W 230 V IN e Bel ftungssteuerung max Leistung 100 W 230 V IN e Abmessungen 272 mm x 70 mm x 193 mm F hler e Der Temperaturf hler WX232 ist mit einem r cksetzbaren berhitzungsschutz und einem NTC Thermistor zur Temperaturerfassung aus gestattet 22 kO T 25 C e Gewicht 175 g mit Leitungen ca 4 m e Abmessungen 51 mm x 73 mm x 27 mm Control panel Bedienfeld Dry area Trockener Bereich Power unit
16. heitsabstand zum Saunaofen ist einzuhalten Abb 4 Mit Hilfe der Kabelverrohrung 30 mm in den Wandkonstruktionen l sst sich das Kabel verdeckt zur Montagestelle des Bedienfeldes legen andern falls ist eine Oberflacheninstallation durchzuf hren Wir empfehlen beim Einbau das Bedienteil so weit wie m glich vom Ofen entfernt einzulassen um es vor Spritzwasser zu sch tzen 3 2 Montage der Leistungseinheit Bringen Sie die Leistungseinheit an einem trocke nen Ort au erhalb der Saunakabine mit einer Um gebungstemperatur von ber 0 C an einer Wand an In Abbildung 5 finden Sie Anweisungen zum Offnen der Abdeckung der Leistungseinheit sowie zur Anbringung an einer Wand Achtung Die Leistungseinheiten d rfen nicht in die Wand eingelassen werden da dies zu einer Uberhitzung der internen Ger tekomponenten und daraus resultierenden Sch den f hren kann Siehe Abbildung 5 RR Figure 5 Opening the power unit cover and mounting the unit to a wall Abbildung 5 ffnen der Abdeckung der Leistungseinheit und Wandmontage des Ger ts 3 2 1 Electrical Connections Figure 6 shows the electrical connections of the power unit For more detailed installation instructions see the instructions for installation and use of the selected heater model 3 2 2 Power Unit Fuse Faults Replace a blown fuse by a new one with the same value The placement of the fuses in the power unit is shown
17. in figure 6 e If the fuse for the electronic card has blown there is likely a fault in the power unit Service is reguired e If the fuse in the line U1 U2 has blown there is a problem with lighting or fan Check the wiring and functioning of lighting and fan 10 3 2 1 Elektrische Anschliisse Abbildung 6 zeigt die elektrischen Anschl sse der Leistungseinheit Weitere Installationsanweisungen finden Sie in der Installations und Gebrauchsanlei tung des ausgew hlten Ofenmodells 3 2 2 Sicherungsdefekte der Leistungseinheit Ersetzen Sie eine defekte Sicherung gegen eine Siche rung desselben Werts Die Position der Sicherungen in der Leistungseinheit ist in Abbildung 6 dargestellt e Ist die Sicherung der Elektronikplatte defekt so liegt wahrscheinlich ein Defekt in der Leistungs einheit vor Wartung ist erforderlich e Ist die Sicherung in Reihe U1 U2 defekt so liegt ein Problem mit Beleuchtung oder Bel f tung vor Pr fen Sie Verkabelung und Funkti onsweise von Beleuchtung und Bel ftung EN DE Temperature sensor Data cable Control panel Temperaturf hler Datakabel Bedienfeld WX325 Optional Wahlweise Temperature sensor Temperaturf hler WX232 Must be installed Mu montiert werden Fuse for relay outputs T2 5 A Ceramic slow Keramisch langsam Fuse for electronic card 40 mA Slow Langsam Fan optional L fter wahlweise Sicherung f r Re
18. ing Check the red and yellow wires to the temperature sensor and their circuit short circuited connections see figure 6 for faulties Kurzschluss im Messkreis des Pr fen Sie die roten und gelben Kabel zum Temperaturf hler und deren Temperaturf hlers Verbindungen siehe Abb 6 auf Fehler E3 Overheat protector s measuring Press the overheat protector s reset button gt 3 4 circuit broken Check the blue and white wires to the temperature sensor and their connections see figure 6 for faulties Messkreis des Reset Taste des Uberhitzungsschutzes dr cken b3 4 Pr fen berhitzungsschutzes Sie die blauen und wei en Kabel zum Temperaturf hler und deren unterbrochen Verbindungen siehe Abb 6 auf Fehler E6 Optional sensor s temperature Check the brown and blue wires to the optional sensor and their measuring component failure connections see figure 6 for faulties Replace the sensor Ausfall der Temperaturmesskom Pr fen Sie die braunen und blauen Kabel zum Temperaturf hler und de ponente des optionalen Fuhlers ren Verbindungen siehe Abb 6 auf Fehler Ersetzen Sie den F hler E9 Connection failure in the system Switch the power off from the main switch figure 1 Check the data cable sensor cable s and their connections Switch the power on Verbindungsfehler im System Schalten Sie den Strom am Hauptschalter ab Abbildung 1 berpr fen Sie das Datenkabel sowie das oder die die F hlerkabel und deren Verbindungen Scha
19. l panel CX1 70 Bedienfeld CX1 70 WX380 2 Temperature sensor Temperaturf hler WX232 3 Temperature sensor optional Temperaturf hler wahlweise WX325 4 Data cable 5m Datakabel 5 m WX311 5 Data cable extension 10 m optional Verlangerungskabel 10 m wahlweise WX313 6 Circuit board Platine WX351 14 HARVIA Harvia Oy PL12 40951 Muurame Finland www harvia fi 358 207 464 000 harvia harvia fi
20. laisausg nge Blue Blau White Wei Red Rot Sicherung f r Elektronikplatte Blue Blau Brown Braun Control of electric heating optional must be fused if used Steuerung der elektrischen Heizung optional muss bei Verwendung gesichert werden Yellow Gelb J e 8 OOO 2220 U1U2 N N 01 a N N LIL2L3W V U Ti tf Tn A Junction box lt Klemmdose B Residual current device RCD Fehlerstromschutzschalter 6 6 vv d L1 L2L3 N WVUN Lighting optional 00000 O 0 fe Beleuchtung wahlweise i 400 V 3N 230 V IN WAR Main max 17 kW max 100 W i A switch P OIL 4 Haupt lt sur D schalter Heater 3 R Z O INO Ofen 9 z i Input oc o Anschlu BR EN re Heater output Fuse B Leistungsabgabe des Ofens Sicherung HO7RN F kW A mm mm 0 6 3x10 5x 1 5 5x 1 5 lt 6 11 3 x 16 59205 53 1 5 lt 11 17 3x 25 5x6 5x 2 5 Figure 6 Electrical connections Abbildung 6 Elektrische Anschl sse 11 EN 3 2 3 Power extension unit LTY17 optional The maximum load of control unit can be increas
21. lten Sie den Strom ein Table 7 Error messages Note All service operations must be done by professional maintenance personnel Tabelle 1 Fehlermeldungen Achtung Alle WartungsmaBnahmen m ssen von gualifiziertem technischem Personal durchgef hrt werden EN 2 INSTRUCTIONS FOR USE 2 1 Using the Heater When the control unit is connected to the pow er supply and the main switch see figure 1 is switched on the control unit is in standby mode and ready for use I O button s background light glows on the control panel WARNING Before switching the heater on al ways check that there isn t anything on top of the heater or inside the given safety distance DE 2 BEDIENUNGSANLEITUNG 2 1 Verwendung des Ofens Wenn das Steuergerat an die Stromversorgung an geschlossen ist und der Hauptschalter siehe Ab bildung 1 betatigt wird befindet sich das Steu ergerat im Standby Modus und ist betriebsbereit Die Kontrollleuchte der I O Taste leuchtet auf dem Bedienfeld ACHTUNG Bevor Sie den Ofen anschalten bitte berpr fen dass keine Gegenst nde auf dem Ofen oder in der unmittelbarer N he des Ofens liegen Display Indicator lights Temperature On time Menu and navigation buttons Value decrease Mode change 1 Press and hold to make the 1 value change faster Operating buttons Heater on off Lighting on off Fan on off Value increase esse Anzeige Kon
22. nakabine an Die untere Zeile zeigt die remaining on time Both indicator lights verbleibende Einschaltzeit an Beide Kontrollleuchten glow leuchten Press the MENU button to open the Offnen Sie das Einstellungsmeni indem Sie die settings menu MENU Taste dr cken 17 F Sauna room temperature Temperatur in der Saunakabine ILI L The display shows the sauna room Das Display zeigt die Temperatureinstellung temperature setting Temperature f r die Saunakabine an Die indicator light blinks Temperaturkontrollleuchte blinkt Aly e Change the setting to the desired e Andern Sie die Einstellung mit den Tasten N temperature with the and buttons und auf die gew nschte Temperatur MN The range is 40 110 C Der Einstellbereich betr gt 40 110 C ME Press the MENU button to access the next Gehen Sie zur n chsten Einstellung ber indem setting Sie die MENU Taste dr cken Remaining on time Verbleibende Einschaltzeit Press the and buttons to adjust the Stellen Sie mit den Tasten und die 34 FI remaining on time verbleibende Einschaltzeit ein J UN SV Example the heater will be on for 3 hours Beispiel Der Saunaofen wird 3 Stunden und or and 40 minutes 40 Minuten lang laufen 11 vi TITA Pre setting time timed switch on Vorwahlzeit zeitgesteuertes Einschalten NOODI Press the button until you overstep e Dr cken Sie die Taste bis die maximale 7Tictiiiy the m
23. on 2 3 2 Ventilation If there is a fan installed in the sauna room it can be connected to the control unit and be controlled from the control panel Start stop the fan by pressing the control panel button DE die Einschaltzeit abgelaufen ist die Entfeuchtung beendet wurde bzw der Ofen manuell ausgeschal tet wurde 2 2 Andern der Einstellungen 5 Die Struktur des Einstellungsmen s und das Andern der Werte wird in den Abbildungen 3a und 3b ge zeigt Der programmierte Temperaturwert und alle weite ren Einstellungswerte werden gespeichert und auch beim n chsten Einschalten des Ger ts verwendet 2 3 Verwendung des Zubeh rs Beleuchtung und Bel ftung k nnen separat ber an dere Funktionen ein und ausgeschaltet werden 2 3 1 Beleuchtung Die Beleuchtung der Saunakabine kann so einge stellt werden dass sie vom Bedienfeld aus gesteu ert werden kann Max 100 W Schalten Sie die Lampen ein oder aus indem Sie die Taste auf dem Bedienfeld dr cken N AS 2 3 2 Bel ftung Wenn in der Saunakabine eine Bel ftung installiert ist kann diese an das Steuerger t angeschlossen und mit dem Bedienfeld gesteuert werden Schalten Sie die Bel ftung ein indem Sie die Taste auf dem Bedienfeld dr cken EN DE BASIC SETTINGS GRUNDEINSTELLUNGEN Basic mode heater on Basis Modus Ofen ein The top row shows the sauna room Die obere Zeile zeigt die Temperatur in der temperature The bottom row shows the Sau
24. onnector Press the front cover into the back cover Kw Ok D di H ei D hi A 35x15mm EA Vordere Abdeckung auf die atakabel des Bedienfelds durch e ffnung in der R ckwand f hren intere Abdeckung mit Schrauben an ner Wand fixieren atakabel in den Stecker schieben ntere Abdeckung dr cken 2 Figure 4 Fastening the control panel Abbildung 4 Befestigung des Bedienfelds EN be at the minimum safety distance from the heater and at a maximum height of one metre from the floor Figure 4 Conductor tubing 30 mm inside the wall struc ture allows you to thread the data cable hidden within the wall otherwise the installation will have to be on the wall surface We recommend you to install the control panel embedded in to the wall and far away from possible splashes 3 2 Installing the Power Unit Install the power unit to a wall outside the sauna room in a dry place with an ambient temperature of gt 0 C See figure 5 for instructions on how to open the power unit cover and how to fix the unit to the wall Note Do not embed the power unit into the wall since this may cause excessive heating of the in ternal components of the unit and lead to damage See figure 5 DE der Sauna montiert muss es in der Saunawand auf max 1 m H he eingelassen werden Eine aufge setzte Montage ist nicht erlaubt Auch der Mindest sicher
25. trollleuchte Temperatur Einschaltzeit Men und Navigationstasten Wert verringern Modus wechseln Wert erh hen zo Gedr ckt halten damit die Werte sich schneller ndern Bedientasten Ofen ein aus Beleuchtung ein aus Bel ftung ein aus Figure 2 Control panel Abbildung 2 Bedienfeld 2 1 1 Heater On W Start the heater by pressing the heater 10 I O button on the control panel When the heater starts the top row of the display will show the set temperature and the bottom row will show the set on time for five seconds When the desired temperature has been reached in the sauna room the heating elements are automatically turned off To maintain the desired temperature the control unit will automatically turn the heating elements on and off in periods If the heater efficiency is suitable and the sauna has been built correctly the sauna takes no more than an hour to warm up 2 1 2 Heater Off The heater turns off and the control unit switches to standby mode when e the I O button is pressed e the on time runs out or e an error occurs NOTE It is essential to check that the control unit has cut off power from the heater after the on time 2 1 1 Ofen einschalten eee Dr cken Sie auf dem Bedienfeld die I O Taste 110 f r den Ofen um den Ofen einzuschalten Beim Einschalten des Saunaofens zeigt die obere Zeile des Displays die eingestellt
26. unit can be used to preset the start of the heater pre setting time See figure 3a 1 2 Technical Data Control panel e Temperature adjustment range 40 110 C e On time adjustment range family saunas 1 6 h public saunas in apartment buildings 1 12 h For longer operating times consult the importer manufacturer Pre setting time adjustment range O 12 h Control of lighting and fan Dimensions 85 mm x 24 mm x 110 mm Length of data cable 5 m 10 m extension cables available max total length 30 m Power unit e Supply voltage 400 V 3N e Max load 17 kW e Lighting control max power 100 W 230 V 1N e Fan control max power 100 W 230 V 1N e Dimensions 272 mm x 70 mm x 193 mm Sensors e The temperature sensor is equipped with a resettable overheat protector and a temperaturesensing NTC thermistor 22 kQ T 25 C e Weight 175 g with leads ca 4 m e Dimensions 51 mm x 73 mm x 27 mm Figure 1 System components Abbildung 1 Komponenten DE 1 HARVIA XENIO 1 1 Allgemeines Der Zweck des Steuerger ts Harvia Xenio ist es ei nen elektrischen Saunaofen innerhalb einer Ausgangs leistung von 2 3 17 kW zu regeln Das Steuerger t besteht aus einem Bedienfeld einer Leistungseinheit und einem Temperaturf hler Siehe Abbildung 1 Das Steuerger t reguliert die Temperatur in der Saunakabine entsprechend der von dem F hler gelieferten Daten Der Temperaturf hler und der berhitzungsschutz befinden sich im G