Home

NuTone Homeowner's Operating Instructions (30042320 rev. 15

image

Contents

1. INSTALLATION TIPS amp USER GUIDE CENTRAL VACUUM POWER UNIT FOR RESIDENTIAL USE ONLY A MopeLSs 475 VX550CC VX1040CC VISIT WWW NUTONE CA FOR THE CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS BROAN NUTONE CANADA INC MISSISSAUGA ONTARIO WWW NUTONE CA 1 888 882 7626 REGISTER YOUR PRODUCT ONLINE AT WWW NUTONE CA 02571 09512 30042320 rev 15 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WHEN USING AN ELECTRICAL APPLIANCE BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY 1 Do not use on wet surfaces or outdoors 2 Do not vacuum liquids or fine powders such as drywall dust 3 Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present 4 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 5 Do not allow to be used as a toy Close attention is necessary when used by or near children 6 Use only as described in this manual Use only manufacturer s recommended attachments 7 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging Use extra care when cleaning on stairs 10 Do not handle plug or appliance with wet hands
2. not by Key No This part MUST be removed and installed by a qualified technician 094123 010052 010052 001027 OO X N N X _ X KEY No 2 EE 1 1 1 SS SS SS 66 Ed X page 15 16 WARRANTY NUTONE MODELS VX475CC VX550CC AND VX1040CC BROAN NUTONE CANADA INC CENTRAL VACUUM POWER UNIT LIMITED LIFETIME WARRANTY Broan NuTone Canada warrants to the original consumer purchaser that its central vacuum power unit will be free from defects in materials and workmanship for as long as you own your home in which it was originally installed with the exception of the motor and electronic components which will be warranted for five 5 years The first year of this warranty covers the parts and labor in an authorized service center THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During these time periods Broan NuTone Canada will at its option repair or replace the power unit or part without charge which is found to be defective under normal use and service THIS WARRANTY DOES NOT APPLY TO THE INSTALLATION OR THE PARTS USED IN THE INSTALLED TUBING SYSTEM All central vacuum hoses electric or air driven brushes filters attachments and accessories are warranted for one 1 year from the original pur
3. 11 Do not use with damaged cord or plug If appliance is not working as it should if it has been dropped damaged left outdoors or dropped into water return it to a Service Center 12 Keep your work area well lighted 13 Connect to a properly grounded outlet only See grounding instructions shown on page 7 14 When performing installation servicing or cleaning the unit it is recommended to wear safety glasses and gloves CAUTION 1 Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow 2 Ensure air flows freely to both side intake vents and exhausts unobstructed from top outlet Do not use without filter in place Do not use to blow leaves or debris Do not put any object on the unit Do not install the unit horizontally Do not use the pail as a wash bucket Do not use the pail as a stool Avoid picking up sharp objects 10 Do not unplug the unit by pulling on cord To unplug grasp the plug not the cord 11 Store your cleaner indoors in a clean dry area 12 Any servicing other than that recommended in this manu al should be performed by an authorized service facility 13 We recommend that your unit be inspected by a specialized technician once a year CAUTION For all models DO NOT REMOVE either of the grey seals covering the REMOVE WARRANTY VOID IF SEAL IS BRO
4. reinstallation works are under the customer responsibility and Broan NuTone Canada cannot be charged for them To qualify for warranty service you must notify Broan NuTone Canada at the address or telephone number stated below We will then forward you the authorized service depot in your area You will be required to present evidence of the original purchase date Date of Installation Builder or Installer Model Number and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest Broan NuTone Canada Inc dealer dial toll free 1 888 882 7626 Please be prepared to provide Product model number e Date and proof of purchase e The nature of the difficulty Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario 51 1H9 Product specifications subject to change without notice Printed in Canada
5. to cut flexible tubing 8 lengths of flexible tubing should not be cut Use a small knife or steel wool to remove any burrs from the inside of the tube Use a file to slightly bevel the outside of the tube so that it will easily slide into the fitting Use steel wool or a light grained sandpaper to buff the surface of the tube which will be glued MAKING A JOINT Insert the tube into the fitting aligning both parts as they will be installed Mark the tube and the fitting to quickly realign the joint Apply cement in inch wide band to the outside of the tube Insert the tube into the fitting with the alignment marks a quarter turn apart and then quickly push and turn the fitting to align the marks and spread the cement Allow 1 minute for the joint to dry aoco10 CEMENTING FLEXIBLE TUBING Ensure the ends of the flexible tubing are even When joining flexible tubing to plastic tubing or to an inlet mounting plate apply cement to both the inside of the flexible tubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE WIRE TO TUBING The low voltage power wiring is run along with the tubing Use electrical tape to secure the wire to the tubing Tape the wire approximately every 12 to 18 WALL INLET INSTALLATION MAKING THE WALL INLET CUTOUT The wall inlet sh
6. wall clearance dimensions 3 Position and install the wall mounting bracket with the provided screws Refer to Fig 3 for proper mounting dimensions CAUTION Ensure to fix the wall mounting bracket with the screws directly onto a stud for a solid installation 4 Using the provided mounting screws secure the mounting bracket on the wall through two upper and two lower mounting holes 5 Hang power unit onto wall mounting bracket Ensure both upper and lower mounting openings on the back of the power unit are engaged with corresponding wall bracket fingers Pull the power unit down to secure 6 Open the door located on the front of the power unit Ensure the cyclonic filter is properly seated See page 13 for reference Close the door UPPER SS SSK SQ CG t LOWER MOUNTING 1 TYP HOLES ADO044A 6 POWER UNIT INSTALLATION cont p FITTING MAIN LINE TO POWER UNIT Your power unit is capable of being connected to the intake vacuum trunk line from either side Select the intake connection to be used Some installations may require the connection into both intakes The power unit has 4 intake connections which 2 of them are factory sealed CAUTION NuTone VX475CC VX550CC and VX1040CC power units will attach to the lower intake connections See Fig 4 Utility valve can be installed on either side 1 Using provided coupli
7. your authorized Service Center Empty debris pail as described in page 12 Contact your local Service Center SERVICE PARTS REPLACEMENT PARTS AND REPAIRS In order to ensure your unit remains in good working condition you must use Broan NuTone genuine replacement parts only Broan NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable 2 18 certification standards and maintain a high standard of safety Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit which will result in premature failing Broan NuTone also recommends to contact a Broan NuTone certified service depot for all replacement parts and repairs AL0001 0941189 Pail assembly VS 0941191 Pail assembly TS 094119 X 094119 X 10941232 8 PCB s assembly including mother daughter and screws 941233 T51 PCB s assembly including mother daughter and screws VX550CC VX1040CC X X X NO 165 i 4 X E 091118 0541235178 motor with motor harness fuse with fuse hamess circuit breaker X 054123 Pail gasket TS Pail gasket VS Cyclonic filter VS 010270 Cyclonic filter TS 0941215 Motor chamber VS with logo 0941216 Motor chamber TS with logo 0941212 Top cap VS with logo 0941214 cap TS with logo NOTE Order service parts by Part No
8. KEN NE PAS ENLEVER GARANTIE ANNULEE SI CE SCEAU EST BRISE TOP red cap plugs Removing these seals will void the warranty Only remove and use the outlets covered by the BOTTOM green plugs OPERATION The power unit is located away from the everyday living areas of your home usually in the garage basement or utility room Through a network of strong lightweight tubing the power unit connects to inlets strategically placed throughout your home To clean attach cleaning tools to the system s hose and insert the hose into an inlet The system is turned on by a power switch on the hose As you vacuum dirt and dust is transported to the power unit where it remains in a debris pail until emptied This electrical appliance has been evaluated by the appropriate listing agencies and is intended for household use only The system status indicator light s on the front of the power unit indicate that the power unit is ready for use Under normal operation the light s will be green A red light on NuTone models VX550CC or VX1040CC indicates a need to empty pail See page 12 for instructions When you are ready to clean attach the wand and cleaning tool onto the end of the hose Open the inlet cover and insert the end of the hose into the inlet For non switched hoses inserting the hose automatically turns on the power unit removing the hose shuts off the power unit Some hoses have switches which can be used to activate power
9. PROBLEMS POSSIBLE CAUSES POSSIBLE REMEDY 1 Loss or decrease of Debris pail is completely full Empty debris pail as described on page 12 vacuum occurs e Obstruction in the hose A blockage in the Insert handle end of hose into utility valve at 2 Power unit does not start or shuts off during normal operation with no LED showing red or illuminated 3 Power unit fails to stop when the hose is removed 4 Power unit shuts off during normal operation lights on unit wall valve and hose are all red 5 NuTone VX550CC and VX1040CC units only all lights on control panel flash when unit is first plugged in can be determined by inserting the hose into any wall inlet and while power unit is running check each additional inlet for normal suction by holding the palm of your hand over the open inlet If normal suction is felt at all other inlets insert the hose into a second inlet If the blockage still exists it is located in the hose However if the blockage does not occur when the hose is changed the blockage is probably located in the tubing system leading to the original inlet Obstruction in the tubing system inside the walls Wall inlet cover not properly sealed Exhaust tubing or vent clogged Defective inlet Check other wall inlets Thermoprotector has been activated OR there is a tripped circuit breaker on the unit Blown fuse or tripped circuit breaker on house electrical panel Defect
10. S USING CRIMP CONNECTORS AND LOW VOLTAGE WIRE HARNESS LOW VOLTAGE NORTH AMERICA AC ELECTRIC WIRE HARNESS OUTLET Ga LO VOLTAGE WIRE 240 VOLT GROUNDED OUTLET BOX N 259 05 CRIMP CONNECTORS NEMA 6 20R 8 FOR MODELS DLXKIT800 STDKIT400 STDKIT800 WHKIT700 INSTALLING HOSE HANGER If not already done install the hose hanger by following these 3 steps Place one loop of the hanger over the other as shown beside Using a screwdriver secure the hanger to the wall with the provided screw Insert a plastic anchor if necessary Wind hose around it s hanger Mi Vie when not in use ST gt i 1 ey ty _ 8 5 CONNECTING HOSE LOW VOLTAGE HOSE To ensure proper operation of hose insert hose into wall inlet as shown beside Align tab up with depression in wall inlet A CONNECTING HOSE cont p DUAL VOLTAGE HOSE In addition to connecting into wall inlet A dual voltage hose must also be connected to a standard electrical outlet B lf your new hose connection is not compatible with the telescopic handle of your unit please call 1 888 882 7626 IMPORTANT Do not return the hose to the store OPERATING HANDLE SWITCH LOW VOLTAGE HOSE The switch will turn power unit ON OFF DUAL VOLTAGE HOSE Switch on the right position C
11. appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Grounding Instructions This appliance must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances This appliance is for use on a standard 120 VAC dedicated 15 amp branch circuit with a NEMA 5 15R receptacle or a dedicated 20 amp branch circuit with a NEMA 5 20R receptacle for NuTone models VX475CC and VX550CC For NuTone model VX1040CC a dedicated nominal 240 VAC individual 20 amp branch circuit with NEMA 6 20R receptacle is required Make sure that the appliance is connected to an outlet and has a grounding attachment plug that looks like the plug shown in either Fig 5 or Fig 6 depending on the model No adapter should be used with this appliance NuTone VX475CC AND VX550CC NOTE INLET LEADS TO BE CONNECTED TO POWER UNIT TERMINALS USING CRIMP CONNECTORS AND LOW VOLTAGE WIRE HARNESS LOW VOLTAGE OUTLET WIRE HARNESS 120 VOLT GROUNDED OUTLET BOX NEMA 5 15R LOW VOLTAGE WIRE NEMA 5 20R AE0030A NuTone VX1040CC NOTE INLET LEADS TO BE CONNECTED TO POWER UNIT TERMINAL
12. ard Rubber bumper protects furniture and baseboards ELECTRONIC CIRCUIT BREAKER The power brush is equipped with an electronic circuit breaker that protects the motor and the belt if a too large object is picked up accidentally If the power brush stops while vacuuming turn the power unit off using handle Release the power brush from the wand and turn it over to see if there is an obstruction When brush roll jam has been cleared press the reset button H and connect the power brush back to the wand Finally turn the power unit power brush back on If it fails to restart or continues to trip without any apparent reason the power brush must be serviced by an authorized service center 0030 CLEANING AND STORAGE Disconnect electrical supply before servicing cleaning the unit Failure to do so can result in electrical shock or personal injury from cleaner suddenly starting CLEANING BRUSH ROLL In order to keep high cleaning efficiency and to prevent damage to your vacuum cleaner the brush roll must be cleaned every time the belt is changed The brush roll must also be cleaned according to the following schedule CLEAN BRUSH ROLL Every week Every month Every 2 months VACUUM CLEANER USE Heavy used daily Moderate 2 3 times per week Light 1 time per week Check and remove hair string and lint build up frequently in the brush roll and end cap areas Remove any dirt or debris in
13. ated on the internal filter media To do this simply open the direct door reach in and tap the top of the internal filter Fig 13 This will release any loose debris into the pail You may empty the pail again at this point but it is not necessary as any amounts of dirt and dust will be minimal Close the door page 13 CLEANING THE SECONDARY FILTER A secondary safety filter located at the top of the vacuum chamber provides additional protection to the motor This filter should be checked and cleaned if necessary when emptying the debris pail Simply brush filter clean If the filter is excessively soiled wash in a mild detergent and let it dry completely before reinstalling CAUTION Operating the power unit without the secondary filter will void the warranty A FILTER REMOVAL Open the door located on the front of the power unit Reach inside the unit and remove both locking sleeves from the retaining hooks Carefully pull filter down to remove NOTE NuTone model VX1040CC has two secondary filters Ensure to remove both filters B FILTER REINSTALLATION To reinstall the secondary filter reverse the steps described above HOOKS AO0066 A replacement secondary filter part no 10941310 may be purchased from your local Broan NuTone Sales Outlet locate your nearest Broan NuTone Sales Outlet call toll free 1 888 882 7626 14 TROUBLESHOOTING GUIDE Read before calling Service Center
14. chase date with the exception to consumables such as light bulbs and belts This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone Canada or an authorized representative faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the period as specified for the express warranty BROAN NUTONE CANADA S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE CANADA S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Please do not return your unit to place of purchase Please visit www nutone ca for your closest service center You may also call 1 888 882 7626 for the name of an authorized representative in your area This warranty supersedes all prior warranties Warranty service is to be completed by an authorized Service Center designated by Broan NuTone Canada Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be repaired or replaced at Broan NuTone Canada s discretion by the nearest authorized service provider The unit removal and
15. cts by hand before using your power brush Items such as pins hairpins tacks crayons etc may damage the brush roll or may break the belt WAND RELEASE The power brush not recommended for use on bare floors Wand release pedal A on power brush allows you to quickly disconnect wand and switch to combination floor rug tool for use on bare floors CAUTION Always unlock brush neck before use POWER BRUSH NECK RELEASE Push down power brush neck release pedal B to unlock brush neck Return the neck to the upright position for storage POWER BRUSH HEIGHT ADJUSTMENT The icons D refer to the carpet pile height Select height by depressing height adjustment pedal C to desired position Extra Low w Low uu Medium or LLL High FLOOR HEIGHT HEIGHT ADJUSTMENT LED INDICATORS The LEDs show the carpet pile covered by the selected height e g when LLU High is selected all LEDs will be lit since this height covers all pile heights So if Extra Low is selected only the lowest LED will be lit WAND LENGTH ADJUSTMENT Extend E or shorten F the wand to comfortable work position by holding the wand grip G in one hand and sliding the upper section the one with the prongs with the other hand V AD0023 EDGE CLEANER Brush extends full width for effective edge cleaning along both sides of nozzle To operate simply run cleaner along edge bo
16. e ca for the Central Vacuum System Installation Instructions POWER UNIT INSTALLATION Do not install outdoors CAUTION For all models DO NOT REMOVE either of the grey seals covering the DO NOT REMOVE WARRANTY VOID IF SEAL IS BROKEN TOP red cap plugs Removing these seals will void the warranty Only pas ENLEVER GARANTIE ANNULEE remove and use the outlets covered by the BOTTOM green plugs MOUNTING Your power unit mounts to the wall using a mounting system The wall mounting bracket provided with your power unit mounts to the wall It has 4 fingers at the top and 4 more at the bottom The power unit has 4 upper openings and 4 lower Openings which are designed to slide onto the wall mounting bracket fingers Ensure to follow the instructions below for proper installation WALL MINIMUM CLEARANCE DIMENSIONS NuTone VX475CC 11 NuTone VX550CC and VX1040CC 1334 24 MINIMUM TO CEILING UTILITY 18 MINIMUM ABOVE FLOOR AD0003A FRONT VIEW page 5 1 Locate power unit within six feet 1 82 m of a grounded electrical outlet NuTone VX475CC and VX550CC power units require a 120 V dedicated 15 amp branch circuit with a NEMA 5 15R receptacle or a dedicated 20 amp branch circuit with a NEMA 5 20R receptacle NuTone VX1040CC power unit requires a 240 VAC dedicated 20 amp branch circuit with a NEMA 6 20R receptacle 2 Refer to Fig 2 to maintain minimum
17. entral vacuum mode with power brush Switch the left position Central vacuum mode without power brush Switch in the center Power unit is turned OFF FOR MODEL DLXKIT800 HOW TO ASSEMBLE POWER BRUSH WAND HANDLE 1 2 Read important safety instructions before installing power brush Ensure hose is disconnected from power supply before installing power brush Push wand into power brush neck so that the lock button snaps in place Connect hose handle into wand quick connector and ensure that the prongs are aligned with the receptacle holes Push until lock button snaps in place CAUTION Always check underside of product for any obstructions prior to use A WARNING Never leave electric power brush unattended while it is plugged in HOSE HANDLE RECEPTACLE BUTTON Hose HANDLE RELEASE BUTTON Power BRUSH RELEASE PEDAL HEIGHT ADJUSTMENT NOTE If your dual voltage hose is not compatible with your new BN200 power brush please contact Broan NuTone Customer service at 1 888 882 7626 to receive a free electrical cord Part no 400 01 that will enable you to connect your new power brush to your hose IMPORTANT Do not return the brush to your retail store page 9 Lock BUTTON RECEPTACLE PRONGS Quick CONNECTOR LocK BUTTON POWER Hose HANDLE 10 HOW TO USE POWER BRUSH WAND CAUTION Always pick up hard or sharp obje
18. ive hose Microprocessor lockup NOTE This applies only to NuTone VX550CC and VX1040CC Low line voltage An electrical short has occurred somewhere in the system Debris pail full sensing has been activated Low line voltage power unit Turn unit on This will reverse normal air flow through the hose and dislodge any clogs Insert hose end into any inlet with power unit running place the palm of your hand over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times should clear the obstruction If the blockage is not cleared contact your nearest Service Center Check all wall inlet covers to be sure they are closed and sealed tightly Inspect and remove any blockages Replace defective wall inlet Turn unit off for 20 minutes then plug unit back in If unit does not start look for the tripped circuit breaker behind the unit a white button has popped up push it back to reset it If circuit breaker trips again unplug your unit and contact your local Service Center Replace fuse or reset circuit breaker on house electrical panel Replace hose as required 1 Push Reset button while unit is engaged OR 2 Unplug unit completely for 60 seconds Contact your local Service Center complete check of all wall inlets and power unit low voltage control lead connections Contact
19. k Also including the practical and easy to use Vacusweep Inlet Valve detailed installation instructions Practical e Use in kitchens mudrooms workshops any residential commercial sweepable areas e Makes it easy for debris and dirt to be quickly swept and removed from non carpet surfaces e Available in black white and ivory Easy to Use Fast and simple installation Rear access for piping permits connections from any direction Fits in the kick space of a cabinet or within a wall e Toe operated to activate open the door by rasing the lever with your toe to turn off close the door by pressing your toe on the ribbed surface 4 GENERAL INFORMATION TOOL LISTING Depending on the installation the use of the following tools may be required The power tools are recommended to make the installation proceed quickly A mask should be worn when cutting ducting and gloves when using glue Wire strippers 1 4 and 1 2 drill bits utility knife putty knife 2 hole saw keyhole saw hammer cold chisel level flashlight drill electrical tape screwdriver wrench hacksaw tape measure safety glasses WORKING WITH PLASTIC TUBING CUTTING TUBING Measure the length of tube needed Allow 5 8 of tubing for inserting into fittings and 1 for placing into flexible tubing Cut the plastic tubing with a hacksaw ensuring that the cut is exactly square Use wire cutters or tin snips
20. nderneath the power brush Always refer to these numbers when inquiring about service NOTE The motor is permanently lubricated and sealed Do not oil the motor at any time POWER BRUSH SERVICE PARTS Key No DESCRIPTION 09235 Wand release pedal 18651 Order Service Parts by Part No not by Key No 12 FOR ALL MODELS VACUUM POWER CONTROL The wand end of the deluxe hoses is equipped with a control ring to regulate suction The control ring covers bleeder hole Open the hole to reduce the suction for cleaning draperies small rugs and other light fabrics Some very thick plush carpets with high density yarns also require reduced suction to make the nozzle easier to push Be sure to close the control ring completely over the hole to produce the maximum power required for most other cleaning tasks WHEN TO EMPTY THE DEBRIS PAIL NuTone model VX475CC has a single indicator light that remains green The level of pail fill for this model can be determined by either viewing through the window on the pail or releasing the carry handles and checking the level of debris in the pail NuTone models VX550CC and VX1040CC have the LED indicators that show the status of the level of debris in the pail The first three lights remain green as pail fills The fourth light is amber and will come on to alert you that the pail is nearly full When the fifth light turns red it is time to em
21. ng part no V127 attach the utility valve assembly to the vacuum trunk line feeding into the power unit The utility valve can be installed on the left or right hand side V127 2 Cap off the unused intake tube with the plastic cap provided 3 Attach exhaust tube to power unit using provided coupling part no V127 if vented to the outside 4 Make sure all tubing connections are air tight 5 The exhaust should NOT be vented into a wall ceiling or concealed space in the house It is recommended to vent the vacuum exhaust air to the outside of the house Exterior vented exhaust lines should be terminated using Model V142 wall caps EXHAUST B CENTER OF EXHAUST TO MOUNTING BRACKET HOLES A OVERALL INTAKE 1 HEIGHT ADO004A DIMENSIONAL CHART Models VX475CC VX550CC VX1040CC 5 10 1 7 INTERNAL WIRING DIAGRAMS e VX475CC VX550CC BLACK YELLOW YELLOW OO CONTROL e VX1040CC RED OR WHITE 240 VOLTS GREEN T BLUE THERMAL PROTECTOR THERMAL ye PROTECTOR RED OR WHITE OO AE0027A CONTROL page GROUNDING INSTRUCTIONS WIRING ANWARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the
22. om worn belt and extract the belt from motor shaft by a twisting motion in the enlarge area 1 specifically made for that purpose Fig 10 5 Install new belt by reversing steps 4 to 1 NOTE To ease belt replacement start by inserting one end around the motor shaft in the enlarged area 1 Insert brush roll through belt until belt is seated in its place Push down brush roll back in place page 11 HOW TO CHANGE BRUSH ROLL Replace brush roll when brush roll brissles are worn to the base support bars level 1 power brush over and using a Phillips 2 screwdriver remove the 3 brush roll cover retaining screws Fig 7 and set aside Remove brush roll cover Fig 8 3 free brush roll from base start by sliding the belt side end and pull brush roll sideways 1 Once disengaged from housing lift brush roll 2 out of its compartment Fig 9 Disengage brush roll from belt Discard worn brush roll Insert new brush roll through belt until belt is seated in its place Push down brush roll back in place 6 Finalise the installation by reversing steps 2 to 1 SERVICE INFORMATION To avoid unnecessary service calls check the belt and brush roll often Replace the belt if it is stretched or cracked Clean the brush roll bristles when they are wrapped with thread and hairs Build up could cause the brush to rotate unevenly The model number and serial number are indicated on the rating label located u
23. ould be located 18 on center from the floor and directly in line with the attic or basement inlet tubing hole previously drilled in the wall plate or header The wall inlet cutout must be exactly 3 high by 2 wide ATTACHING THE INLET MOUNTING PLATE Reach through the inlet hole and locate the inlet tubing Pull the flexible tubing through the inlet hole and remove the low voltage wiring from inside the tube Remove the nail flange from the inlet mounting plate Fig 1 Apply cement to both the inside of the flexible tubing and to the outside of the mounting plate s tube ring Insert the mounting plate s tube ring in the flexible tubing and twisting the pieces as you join them to spread the cement and align the mounting plate in a vertical position 0040 Now strip the ends of the two low voltage wires and then connect the wires to the screw terminals on the back of the inlet cover When the wiring is complete assemble the inlet cover to the tube guard and mounting plate COMPLETING THE INLET ASSEMBLY Once you have attached the mounting plate to the flexible tubing pull the low voltage wire through the top wiring hole in the mounting plate a INSTALLING THE INLET Place the inlet into the wall cutout the inlet cover remains on the outside Hold the inlet in place and gradually tighten down each screw a little bit at a time ANDOR For more details on inlet installation visit www nuton
24. pty the pail see CONTROL PANEL DIAGRAM A below CONTROL PANEL DIAGRAM A NuTone VX475CC Manually check pail to determine fill level GREEN ONLY NuTone VX550CC and VX1040CC 00000 Timed pail full indicators 1 Wa GREEN AMBER RED RESET EMPTYING THE DEBRIS PAIL Your power unit has a permanent filter that is self cleaning under normal conditions The filter protects the motor and stops small dirt particles from escaping to the outside of the power unit The filter cleans itself by moving up when the power unit starts and dropping down when the unit is turned off The filter can be removed by means of a pull tab for cleaning if desired Be sure to reinstall properly Correct placement is critical to insure proper protection for the motor 1 Release both carry handles on side of the unit by pulling out and then pushing up Fig 11 Holding the pail by the handles lower it from unit Fig 12 2 Carry pail to trash receptacle and empty 3 Reattach pail using handles 4 Push Reset button on control panel Light on control panel will change to green on NuTone models VX550CC and VX1040CC Utility valve circled in Fig 12 next to power unit can be used to service area around where power unit is installed EMPTYING THE DEBRIS PAIL CLEANING THE INTERNAL FILTER When emptying the debris pail it is a good idea to also clear any dust and dirt that may have accumul
25. the belt path and in the brush roll areas CLEANING HOUSING To keep the power brush housing clean it can be wiped with a damp cloth and a mild soap solution then thoroughly dried Never use any type of chemical as they can damage the housing STORAGE 1 Ensure that hose and power cord are disconnected from wall inlet before unplugging power brush 2 Disconnect hose handle from wand 3 Always keep hose neatly coiled when not in use 4 When not in use the power brush should be stored in a clean dry place MAINTAINING THE POWER BRUSH ASTIN ANIC Disconnect electrical supply before servicing or cleaning the unit Failure to do so can result in electrical shock or personal injury from cleaner suddenly starting HOW TO CHANGE BELT AS INN Ne Motor shaft can become hot during normal use To prevent burns avoid touching the motor shaft when replacing the drive belt RETAINING SCREWS 1 Turn power brush over and using a Phillips no 2 screwdriver remove the brush roll cover f retaining screws Fig 7 and EA 561 85106 1 1 2 Remove brush roll cover Fig 8 1 1 SST C BRUSH ROLL 3 free brush roll from base start by sliding the belt side end and pull brush roll sideways 1 Once disengaged from housing lift brush roll 2 out of its compartment Fig 9 4 Disengage brush roll fr
26. unit NOTE The power unit will not turn automatically ON when the hose is inserted into its own inlet To turn the power unit inlet ON use the rocker switch located on the side of the power unit Use the cleaning tools as you would for any other vacuum cleaner Avoid picking up pine needles coffee sticks and other similar objects These kinds of objects may become lodged in the hose or tubing 3 TABLE OF CONTENTS GENERAL INFORMATION Tool Listing Working with Plastic Tubing WALL INLET INSTALLATION POWER UNIT INSTALLATION Mounting Fitting Main Line to Power Unit INTERNAL WIRING DIAGRAMS VX475CC VX550CC amp VX1040CC GROUNDING INSTRUCTIONS FOR MODELS DLXKIT800 STDKIT400 STDKIT800 AND WHKIT700 Installing Hose Hanger Connecting Hose Operating Hande Switch FOR MODEL DLXKIT800 How to Assemble Power Brush Wand Handle Wand and Hose Compatibility How to Use Power Brush Wand Cleaning amp Storage Maintaining the Power Brush Service Information Power Brush Service Parts FOR ALL MODELS Vacuum Power Control When to Empty the Debris Pail Emptying the Debris Pail TROUBLESHOOTING GUIDE SERVICE PARTS CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS Please visit www nutone ca for the Central Vacuum System Installation Instructions including System Planning and Layout General Installation Installation in New Construction Installation in Existing Construction Tubing System Assembly Final System Chec

Download Pdf Manuals

image

Related Search

Related Contents

DTS 5800    RPW-5000 Camera d`Inspection  the PDF user manual  Playing a Video File  Guide de l`application du système d`intercom vidéo - psn  

Copyright © All rights reserved.
Failed to retrieve file