Home

User Manual

image

Contents

1. 7 3 SAFETY 10 Ere Len cesa ID 10 4 OPERATION 14 Installing the Mattress Replacement 5 4 4 4 482 14 Installing the Side Ralls ys eded a Re EEE HG ve EVE D eb ERN Der STE Ee EV N a a e Installing the Control Unit Connecting the Hose er a da E bee e ER NU uc ce aaa E e Connecting the Power COrd co ken aet ER DR Med e n aa P aee P Dd diee b ua a 17 Using the Front Panel eco o Re RT ERG MEE tbe 19 Powering Upithe Nade Sat a ads 24 Placing the pi dna 25 Transferring Patient From To 26 Transferring Patient Froin To a Wheelchair tette hte deett aia li soda du pa li a ot 26 tg da EVEN WAVE EAREKE ada d 27 5 MAINTENANCE AND TROUBLESHOOTING 28 Cleaning the System ia MD ND a a aa dua 28 Changing the Filter sia s
2. 4 6 Using the Front Panel DETAIL A MA80 Fowler Button Power Fail LED Low Pressure LED FRONT PANEL l aia Low Air Loss A Low Pressure Power Fail Power Button inflate Static Button Lock Alarm Button Soft Button Max Inflate Button LCD Display Firm Button DETAIL B Alternating Pressure Button MA85 FRONT PANEL Fowler Button Power Fail LED Low Pressure LED A Low Pressure Power Button e STATIC ALTERNATING PRESSURE Inflate Static Button Lock Alarm Button Soft Button Max Inflate Button LCD Display Firm Button FIGURE 5 Using the Front Panel Part No 1148138 19 Invacare 80 Series Mattresses 4 Power Button To turn the control unit on or off press and release the Power button O Once the unit is plugged in an AMBER LED on the control unit is lit indicating that the system is in STAND BY mode Once the Power button is pressed and released a GREEN LED illuminates indicating that the control unit is on If the power comes on after a power outage the control unit will go through its system initialization routine for a few seconds and then resume the desired function Pulse Button MA80 Power Unit Press the Pulse button to turn Pulse mode and select one of four Pulse Times 3 5 or 0 minutes The pulse times are 3 5 or 10 minutes The pulse times indicate the time between each lo
3. 80 series check the underside of the mattress folds for sharp objects such as scissors needles etc These objects should be removed and discarded before proceeding with further cleaning or disassembly otherwise injury or damage to the product may occur Because of potential risk of infectious exposure cleaning with the patient on the bed is not recommended equipment should be inspected Any item that is visibly soiled with the patient s blood or other body fluids should be properly cleaned or removed Laundry workers should treat all soiled bedding as if it were contaminated with pathogenic microorganisms Remove the bedding If necessary inflate the mattress Ensure that the control unit is off Unplug the power cord from the wall outlet Ensure that the underside of the mattress is clear of all sharp objects Examine the surface of the control unit and mattress assembly components for visible blood or body fluids Dico Ur hec Um Perform one of the following If blood is present decontaminate the product i Remove all visible soil with disposable paper towels ii Scrub the area with freshly prepared effective phenolic detergent disinfectant solution fblood is not present remove any soil from the cover with paper towels Invacare MA80 Series Mattresses 28 Part No 1148138 5 MAINTENANCE AND TROUBLESHOOTING If soiled the cover should be removed cleaned and decontaminated 8 Perform the followi
4. Contact Invacare Carrier for further instruction Contraindications WARNING ALWAYS consult the patient s physician before using the MA80 and MA85 systems Invacare MA80 Series Mattresses 10 Part 1148138 3 SAFETY Installation A WARNING 80 series and 85 series systems including bariatric and raised side rail is recommended to be installed on medical bed frames with bed side or assist rails It is preferred that the rails be the raised position whenever a patient is on the bed Health care professionals assigned to each case should make the final determination whether side or assist rails are warranted after assessing patient risks of entrapment and falls in accordance with State patient restraint legislation or facility interpretation of such legislation Controls on the footboard may be obstructed by the control unit on a few bed frames It may be necessary to relocate the control unit Refer to Installing the Control Unit on page 16 Check that air hoses and power cord are clear of moving bed components before placing a patient on the bed Operate all bed frame motorized functions through their full range of motion to be certain that there is no pulling interference or pinching DO NOT strap the mattress to the bed frame at the head and foot ends Secure ALL mattress straps Secure the straps to the bed deck at the head and foot ends and to the frame at the center of the bed Otherwise damage to the mattre
5. the product Grounding reliability depends upon a properly grounded receptacle 3 prong Part No 1148138 Invacare MA80 Series Mattresses 4 OPERATION 4 Operation A CAUTION The control unit and mattress on the MA80 series are designed to be used as a system DO NOT replace mattresses or control units with other models or other brands Otherwise damage to the system may occur Contact your supplier to get the correct replacement if needed 41 Installing the Mattress Replacement System CAUTION DO NOT strap the mattress to the bed frame at the head and foot ends Secure ALL mattress straps Secure the straps to the bed deck at the head and foot ends and to the frame at the center of the bed Otherwise damage to the mattress will occur when the head and foot ends are raised Head End of Bed Deck Center of Bed Frame DO NOT strap here y Foot End of Bed Deck Invacare MA80 Series Mattresses 14 Part 1148138 The powered mattress comes with ten nylon buckle straps Remove the original foam mattress from the bed If necessary lower side rails to facilitate installation of the mattress Unroll the powered mattress and place it on the bed frame Ensure that hose is towards the foot end of the bed Use the buckle straps to secure the powered mattress to the bed deck in the following locations Head End Head End Bed Deck e Foot End Foot End Bed Deck Center Center of the Bed Frame Installing the Si
6. Charcoal Air Filter with Fire Retardant 8 Part No 1148138 2 OVERVIEW Environmental Parameters 80 85 OPERATING CONDITIONS AMBIENT TEMPERATURE 50 104 RELATIVE HUMIDITY 30 75 Non Condensing ATMOSPHERIC PRESSURE 70 106 kPa STORAGE AND SHIPPING CONDITIONS AMBIENT TEMPERATURE 40 158 RELATIVE HUMIDITY 10 100 ATMOSPHERIC PRESSURE 50 106 kPa Part No 1148138 9 Invacare MA80 Series Mattresses 3 SAFETY 3 Safety 3 1 General Guidelines A WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner s manuals service manuals or instruction sheets supplied with this product or optional equipment If you are unable to understand the warnings cautions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur A ACCESSORIES WARNINGS Invacare products are specifically designed and manufactured for use conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products NOTICE THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE Check all parts for shipping damage and test before using In case of damage DO NOT use
7. ERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROVINCIAL LAWS AND REQUIREMENTS Part No 1148138 5 Invacare MA80 Series Mattresses 2 OVERVIEW 2 Overview 2 1 Label Location DANGER EXPLOSION HAZARD DO NOT use in the presence of flammable anesthetics This label is on the back CAUTION Equipment should be connected to a properly grounded receptacle 3 prong Risk of of the unit and also Electrical shock DO NOT remove back Disconnect air hose before administering CPR contains the serial number ATTENTION Clean Filter Every 5 months and Whenever Dirty Remove Filter Wash amp Replace WARNING Patient entrapment with bed side rails may cause injury or death Mattress MUST fit bed frame and side snugly to prevent patient entrapment Follow the manufacturer s instructions Monitor patient frequently Read and understand the Owner s Operator s Manual prior to using this equipment Invacare product anuals are available at www invacare com or your dealer p nl 150708 Rev A
8. Invacare MA80 Series Mattresses 6 Part No 1148138 22 Product Parameters Electrical Parameters 2 OVERVIEW 80 85 INPUT VOLTAGE AC 0 INPUT FREQUENCY 60 Hz CURRENT 2 A MAXIMUM POWER CONSUMPTION 150 10 W CIRCUIT PROTECTION Dual fused 250 V 5 A fast blow fuses MODE OF OPERATION Performance Parameters WEIGHT CAPACITY STANDARD MATTRESS BARIATRIC MATTRESS PRESSURE ZONE MAXIMUM FLOW MAXIMUM PRESSURE MAXIMUM FLOW TIMER SUPPORT SURFACE INFLATION TIME Part No 1148138 Continuous 350 Ibs 42 mattresses 650 Ibs 48 mattresses 1000 Ibs 5 1275 100 LPM 35 5 mmHg 15 minutes 25 60 seconds Invacare MA80 Series Mattresses 2 OVERVIEW COMFORT CONTROL PRESSURES SOFT PRESSURE FIRM PRESSURE 8 4mmHg 32 4mmHg CYCLE TIME 3 5 10 minutes 5 10 15 20 minutes PATIENT CONTACT Mechanical Parameters Control unit and mattress have Latex Free components CONTROL UNIT DIMENSIONS I5 x 6 5 x I 15 x 65 x I WEIGHT POWER CORD CONNECTION PACKAGING 15 Ibs 10 14 Feet Long Three Prong Grounded Plug 10 14 Feet Long Three Prong Grounded Plug One A Single Quick Disconnector Triple Flow Two gt and One 4 Single Magnetic Quick Coupling piece box AIR FILTER Invacare MA80 Series Mattresses
9. ajor leak in the air cushions or overlay pad Replace leaking air cushions or overlay pad Kinked or split manifold Unkink manifold or replace split manifold Has power and fuse is good control unit does not come on Send unit back for repair Not alternating valve malfunction Send control unit back to factory for repair No air blower malfunction Send unit for repair Invacare MA80 Series Mattresses Control unit off Check power source and turn on unit Power cord disconnected Connect power cord to the power source No power in the power source Check power source has power power and turn it On Power outage Wait till the power source has power Blown fuse 32 Replace blown fuse with an equivalent fuse Part No 1148138 NOTES NOTES Part No 1148138 33 Invacare MA80 Series Mattresses NOTES NOTES Invacare MA80 Series Mattresses 34 Part No 1148138 NOTES NOTES Part No 1148138 35 Invacare MA80 Series Mattresses Part 1148138 Rev D 1 11 Invacare Corporation USA One Invacare Way Elyria Ohio USA 44036 2125 800 333 6900 www invacare com Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800 668 5324 Yes you can
10. are MA80 Series Mattresses 16 Part No 1148138 4 5 Ensure the hose connector is flush with the control unit connector Connector Cover DETAIL Hose Connector Control Uni Connector Control Unit Holes FIGURE 3 Connecting the Hose 4 5 Connecting the Power Cord WARNING DO NOT alter plug to fit a non conforming outlet Instead have an electrician install a properly grounded outlet Failure to use the correct plug and outlet can result in a potential safety hazard CAUTION Ensure that the power cord of the control unit is not pinched or has any objects placed on it and also ensure it is not located where it can be stepped on or tripped over Part No 1148138 17 Invacare MA80 Series Mattresses 4 Examine the hospital grade power cord supplied with the control unit 2 Perform one of the following If the plug is damaged Call your supplier for a replacement hospital grade cord Ifthe plugis not damaged Plug the end of the supplied hospital grade power cord into the power outlet on the side of the control unit 3 Plug the other end of the plug into a properly grounded outlet on the wall Once the unit is plugged in an AMBER LED on the control unit is lit indicating that the system is in STAND BY mode Invacare MA80 Series Mattresses 18 Control Unit Power Outlet FIGURE 4 Connecting the Power Cord Part No 1148138 4
11. ate as much as possible during the deflation time when using 10 15 or 20 minute Alternating Pressure times The setting can be changed so the mattress will only deflate to 50 of the selected pressure setting Ensure the Standby LED is lit 2 Press and hold the Alternating Pressure m and Fowler B buttons 3 Read the LCD Display The LCD Display will show O ifthe current setting is 0 2 mmHg bifthe current setting is 50 of the selected pressure The On and Standby LEDs will be lit 4 Press the Soft W or Firm A buttons to toggle between the two settings 5 Press the Power button to save the setting The control unit will exit this adjustment mode if no button is pressed for 30 seconds Static Button l Press the Static button to select the static mode and maintain the mattress at constant pressure The Static LED is illuminated Green Part 1148138 21 Invacare MA80 Series Mattresses 4 OPERATION Firm Soft Buttons Select comfort pressure settings by pressing Firm A or Soft WM buttons Soft Button Pressing this button reduces the pressure in the mattress Firm Button Pressing this button increases the pressure in the mattress The patient comfort pressure ranges from Soft level 0 6 4 mmHg to Firm level 9 3246 mmHg The Comfort Control LED displays the patient comfort pressure levels from 0 to 9 and provides a guide to the caregiver to set approximate comfort pressure leve
12. de Rails A WARNING 4 OPERATION Powered Mattress Head End F Buckle Straps Foot End Hose FIGURE Installing the Mattress Replacement System Patient entrapment with bed side rails may cause injury or death Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment Follow the manufacturer s instructions Monitor patient frequently Read and understand the Owner s Operator s Manual prior to using this equipment Invacare product manuals are available at www invacare com or your dealer Refer to the instructions provided with the side rails for the installation procedure Part No 1148138 Invacare MA80 Series Mattresses 4 4 3 Installing the Control Unit Bed Hook Pull out the bed hook on the back of the control unit 2 Place the control unit on the footboard If the bed does not have a footboard place the control unit on a flat surface leaving room for the hose to hang down i a FIGURE 2 Installing the Control Unit 4 4 Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress is routed such that it cannot be stepped on kinked squeezed or otherwise damaged Locate the hose at the foot end of the mattress 2 Locate the control unit connector on the right side of the control unit 3 Lift and hold the connector cover up 4 Push the hose connector Detail A onto the control connector Invac
13. esult in entrapment or other injury Invacare MA80 Series Mattresses 12 Part 1148138 Fire Hazard A Electrical A 3 SAFETY DANGER Smoking DO NOT SMOKE while using this device This system uses room air for circulation through the mattress A cigarette can burn a hole in the bed surface and cause damage to the mattress Also patient clothing bed sheets etc may be combustible and cause a fire Failure to observe this warning can result in severe fire property damage and cause physical injury or death Smoking by visitors in the room will contaminate the system Therefore visitor smoking is NOT permitted Anesthesia Equipment There is explosion risk if used with flammable anesthetics Oxygen There is a possible fire hazard when used with oxygen administering equipment other than nasal mask or half bed tent type The oxygen tent should NOT extend below mattress support level DANGER Electrical shock hazard DO NOT remove cover Refer to qualified service personnel Before performing any maintenance to the control unit disconnect the power cord from the wall outlet DO NOT insert items into any openings of the control unit Doing so may cause fire or electric shock by shorting the internal components The control unit MUST be kept away from all heat sources and radiators during operation Connect the equipment to properly grounded three prong wall outlet using 10 14 ft hospital grade power cord provided with
14. l depending on the patient weight If the patient s weight to height ratio is above average increase the pressure setting by approximately 2076 Fowler Button Manual Mode Press the Fowler button 8 to activate the patient fowler mode The Fowler LED illuminates when in this mode When this mode is activated the control unit increases the pressure in the mattress to prevent the patient from bottoming out Automatic Wireless Mode When the bed articulates to 45 the transmitter in the head of the mattress signals the control unit to add 25 more air into the mattress to prevent the patient from bottoming out Fowler Transmitter Setup lI Make sure the bed is in the flat position 2 Make sure fowler transmitter is in the mattress cover pocket in the orientation indicated on the transmitter Invacare MA80 Series Mattresses 22 Part No 1148138 4 The mattress cover pocket is on the inside of the lower mattress cover on the left side of the head end of the mattress o 3 Press and hold the Fowler B and Max Inflate 8 buttons The Fowler LED is lit and L displays in the LCD Display 4 Raise the bed to 45 The control unit will beep and will return to Standby 5 one of the following Cancel Press the Fowler button to exit Fowler Transmitter Setup without linking to a transmitter Save Wait 60 seconds without pressing a key Max Inflate Button l Press the Max I
15. llowing steps Ensure that the patient is lying flat on his her back in the middle of the mattress Place four fingers between the air cushions directly underneath the sacral region of the patient s body Ensure that there is 3 to 4 finger width clearance between the bottom of the patient and the bed frame Adjust the comfort setting if needed g 6n g gt Wait five minutes for the mattress pressure to stabilize Repeat STEPS A E until patient has bottomed out and patient comfort is achieved If the patient feels that the bed is too soft hard press the Soft or Firm button to adjust the comfort settings Use a regular pillow to help support and stabilize the patient s head Part No 1148138 25 Invacare MA80 Series Mattresses 4 4 9 Transferring Patient From To Gurney A WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney Engage the wheel locks of the bed Refer to the owner s manual provided with the bed Engage the wheel locks of the gurney Refer to the owner s manual provided with the gurney Press the Max Inflate button to achieve maximum mattress pressure Raise or lower the bed to match the gurney height Refer to the owner s manual provided with the bed che ONS When the mattress has reached maximum firmness perform one of the following Bed to Gurney Transfer Slide the patient o
16. microA R CLAS Invacare 4 80 Series Mattresses 80 True Low Air Loss System User Manual 80 42 True Low Air Loss Bariatric 42 80 48 True Low Air Loss Bariatric 48 MAS80RSR True Low Air Loss Raised Side Rail 85 True Low Air Loss and Alternating Pressure System 85 True Air Loss and Alternating Pressure M85B42 True Low Air Loss and Alternating Pressure Bariatric 42 85 48 True Low Air Loss and Alternating Pressure Bariatric 48 MAB85RSR True Low Air Loss and Alternating Pressure Raised Side Rail This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference Yes you can 9 2011 Invacare Corporation All rights reserved Republication duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Invacare MA80 Series Mattresses 2 Part No 1148138 5 GENERAL 4 np caca e acad i d a aaa ad 4 Limited W rr nty sii aci na Nede KE aa dai 8 a a a le eed d a a oa t aa Du note 5 2 OVERVIEW 6 PE AEE EE E E sabe toaseodbesadooibsdinsonsbstabecnepoiss 0 noa a di 6 Typical Product xcci p peu
17. nflate button to select the max inflate mode inflate the mattress rapidly to maximum firmness pressurized to 35 6 mmHg A series of beeps sound every three minutes as a reminder that the Max Inflate mode is active After 30 minutes the Max Inflate mode deactivates and the control unit defaults to the previous setting It takes 25 60 seconds for the mattress to inflate fully inflation time depends on size of mattress It is recommended that Max Inflate setting be used during patient ingress egress patient wound care patient turning or patient cleaning 2 Press the Max Inflate button again to manually disengage Max Inflate mode This will deactivate the Max Inflate LED Part 1148138 23 Invacare MA80 Series Mattresses 4 Lock Alarm Silence Button Press the Lock Alarm Silence button A to select one of the following modes Lock Mode Pressing this button locks out all control unit functions including the On button to prevent any tampering with the settings Press the button for approximately 3 5 seconds for the Lock LED to activate The Lock LED illuminates when in this mode Alarm Silence mode Pressing this button silences the alarm that sounds in the event of power failure or when the hose is disconnected from the control unit The Alarm LED illuminates when in this mode Power Fail LED In the event of power outage an alarm sounds and the Power Fail LED flashe
18. ng steps to clean the mattress cover A Using a clean sponge or paper towel wipe down the cover surface with a dilute detergent solution of quaternary cleaner disinfectant or other germicidal detergent solution B Remove the cover and launder it using the following method A CAUTION Laundry workers should always wash their hands before working with clean bedding Do NOt overload the machine Do not use chlorine bleach because it may damage the fabric coating High air temperatures will damage the fabrics and void the Invacare warranty i Place the cover a washing machine ii Wash with warm water below 120 F iii Add detergent and disinfectant according to the manufacturer s instructions iv Remove excess water v Set the dryer to the lowest setting below 120 F vi Dry the cover until it is completely dry 9 Perform the following steps to clean the control unit and hose fittings A Wipe all controls chassis and hose fittings with a quaternary disinfectant solution B Using a nylon brush gently clean all crevices as they can harbor microorganisms C Air dry all treated surfaces Part No 1148138 29 Invacare 80 Series Mattresses 5 MAINTENANCE AND TROUBLESHOOTING 10 Perform the following steps to clean the mattress components air cushions mattress base etc A Using a clean sponge or paper towel wipe down the mattress components with a dilute detergent solution of quaternary cleaner disinfectant or othe
19. nto the gurney Gurney to Bed Transfer Slide the patient onto the bed 4 10 Transferring Patient From To a Wheelchair A WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the wheelchair before transferring the patient between the bed and the wheelchair Engage the wheel locks of the bed Refer to the owner s manual provided with the bed Engage the wheel locks of the wheelchair if applicable Refer to the owner s manual provided with the wheelchair Press the Max Inflate button to achieve maximum mattress pressure Raise or lower the bed to match the wheelchair height Refer to the owner s manual provided with the bed oA ow When the mattress has reached maximum firmness perform one of the following Bed to Wheelchair Transfer Slide the patient onto the wheelchair Wheelchair to Bed Transfer Slide the patient onto the bed Invacare MA80 Series Mattresses 26 Part No 1148138 4 OPERATION 4 11 Preparing for CPR Procedure the connector cover Detail A 2 Pull the hose connector Detail B from the control unit connector DETAIL A DETAIL Connector Hose Cover Connector Control Unit Connector Holes Control Unit FIGURE 6 Preparing for CPR Procedure Part 1148138 27 Invacare MA80 Series Mattresses 5 MAINTENANCE AND TROUBLESHOOTING 5 Maintenance and Troubleshooting 5 1 Cleaning the System A WARNING Before cleaning or disassembling the
20. ocata cata oa cap a pda a 8 35 o Aa i a e da a aa e o 3l Ense lee KAN N 32 Part No 1148138 3 Invacare 80 Series Mattresses GENERAL General 1 1 Symbols Warnings Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage See the information below for definitions of the signal words DANGER Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Caution indicates a potentially hazardous situation which if not avoided may result in property damage or minor injury or both IMPORTANT Indicates a hazardous situation that could result in damage to property if it is not avoided Gives useful tips recommendations and information for efficient trouble free use Invacare MA80 Series Mattresses 4 Part No 1148138 GENERAL 1 2 Limited Warranty PLEASE NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare or a dealer This warranty is not extended to any other person or entity and is not transferable or a
21. r germicidal detergent solution B Wipe the mattress components with a clean dry cloth Storing the System Ensure that the control unit is off and disconnect the power cord from the wall outlet Clean the system Refer to Cleaning the System on page 28 Disconnect the air hose connector from the control unit and allow air to vent from the mattress Gently roll up the mattress with minimal handling and agitation Ensure the cover surface is inside the roll Su oh oC M Store the unit keeping the mattress with the control unit Invacare 80 Series Mattresses 30 Part No 1148138 5 2 Ov Uy st 29 Changing the Filter Clean the filter every 5 months or whenever it is O dirty Remove the two screws securing the filter cover to the back of the control unit Remove the filter Wash the filter with water and a mild detergent Dry the filter completely Install the filter into the back of the control unit Secure the filter cover to the back of the control unit using the two screws Part No 1148138 3l 5 MAINTENANCE AND TROUBLESHOOTING Filter Cover Screws FIGURE I Changing the Filter Invacare MA80 Series Mattresses 5 MAINTENANCE AND TROUBLESHOOTING 5 3 Troubleshooting PROBLEM Mattress not inflating Not alternating properly Mattress hose disconnected SOLUTION Connect hose connectors and lock them in place Air hose kinked or split Unkink hose or replace split hose M
22. s AMBER The control unit has internal memory and retains the previous settings during the power outage Low Pressure LED In the event that the mattress hose disconnects an alarm sounds and Low Pressure LED flashes AMBER Once the low pressure problem is fixed the control unit resumes operation in the previously set mode 4 7 Powering Up the System For this procedure refer to FIGURE 5 on page 19 Turn on the power to the system by pressing the Power button on the control unit Once the button is released a green led illuminates when the unit is on Invacare 80 Series Mattresses 24 Part 1148138 4 8 9 N 9 t 9 10 4 Placing the Patient on the Mattress Press the Max Inflate button to turn on the control unit to maximum flow In this mode the Max Inflate Led lights up After the mattress is fully inflated place the patient on the bed Ensure that the patient s feet are towards the foot end of the mattress the end with the hose Center the patient on the bed from side to side and head to foot Special positioning may be required with contracted patients to provide comfortable positions After placing the patient make certain no objects will fall under the patient such as feeding tubes IV s etc Wait five minutes for the mattress pressure to stabilize Set the comfort pressure to the desired comfort level Verify that the patient has not bottomed out by performing the fo
23. s name address model number and the date of purchase indicate nature of the defect and if the product is serialized indicate the serial number Invacare Corporation will issue a return authorization The defective unit or parts must be returned for warranty inspection using the serial number when applicable as identification within thirty days of return authorization date DO NOT return products to our factory without our prior consent C O D shipments will be refused please prepay shipping charges LIMITATIONS AND EXCLUSIONS THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS IN ADDITION THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED PRODUCTS SUBJECTED TO NEGLIGENCE ACCIDENT IMPROPER OPERATION MAINTENANCE OR STORAGE OR PRODUCTS MODIFIED WITHOUT INVACARE S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND INVACARE S CONTROL PRODUCTS REPAIRED BY ANYONE OTHER THAN AN INVACARE DEALER SUCH EVALUATION SHALL BE SOLELY DETERMINED BY INVACARE THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF M
24. ss will occur when the head and foot ends are raised Refer to Installing the Mattress Replacement System on page 4 Part No 1148138 Invacare MA80 Series Mattresses 3 SAFETY Entrapment May Occur A WARNING Patient entrapment with bed side rails may cause injury or death Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment Follow the manufacturer s instructions Monitor patient frequently Read and understand the Owner s Operator s Manual prior to using this equipment Invacare product manuals are available at www invacare com or your dealer Proper patient assessment and monitoring and proper maintenance and use of equipment is required to reduce the risk of entrapment Variations in bed rail dimensions and mattress thickness size or density could increase the risk of entrapment Visit the FDA website at http www fda gov to learn about the risks of entrapment Review A Guide to Bed Safety published by the Hospital Bed Safety Workgroup located at www invacare com Use the link located under each bed rail product entry to access this bed safety guide Refer to the owner s manuals for beds and rails for additional product and safety information After any adjustments repair or service and before use make sure all attaching hardware is tightened securely Assist rails with dimensions different from the original equipment supplied or specified by the bed manufacturer may not be interchangeable and may r
25. ssignable to any subsequent purchaser or owner Coverage under this warranty will end upon any such subsequent sale or other transfer of title to any other person This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state Invacare warrants the mattress and cover when purchased new and unused to be free from defects in materials and workmanship for a period of one year from the date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty Invacare warrants the control unit when purchased new and unused to be free from defects in materials and workmanship for a period of two years from the date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty If within such warranty period any such product shall be proven to be defective such product shall be repaired or replaced at Invacare s option This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product Invacare s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or replacement For warranty service please contact the dealer from whom you purchased your Invacare product In the event you do not receive satisfactory warranty service please write directly to Invacare at the address on the back cover Provide dealer
26. w pulse For example if 5 minutes is selected all the air cushions in the mattress will inflate for 5 minutes the selected time to the selected comfort setting and then drop 20 pressure for 20 seconds Alternating Pressure Button MA85 Power Unit Press the Alternating Pressure button m to select one of four alternating pressure modes The alternating pressure times indicate the frequency of deflation or inflation of half of the air cushions even or odd numbered For example 10 minutes is selected For example 10 minutes is selected In this example the even numbered air cushions in the mattress will deflate while the odd numbered cushions remain at constant pressure When 10 minutes has elapsed the even numbered air cushions will inflate while the odd numbered cushions remain at constant pressure When 10 minutes has elapsed again the odd numbered air cushions deflate while the even numbered cushions remain at constant pressure The air cushions continue to inflate or deflate like this as long as an alternating pressure time has been selected At all times half of the air cushions remain at a constant pressure when an alternating pressure time has been selected Invacare 80 Series Mattresses 20 Part 1148138 4 Adjusting the Minimum Pressure Setting Low The minimum pressure setting during Alternating Pressure is set to 0 2 mmHg at the factory This means that the mattress will defl

Download Pdf Manuals

image

Related Search

Related Contents

Product Name - The DOW Chemical Company  Techsolo TP-450 Plus  User Manual: Trace Administrator Guide  Liste de thèmes développés dans les numéros Echanges      MZK-5C300D - プラネックスコミュニケーションズ  Dossier de candidature C.A.M.P.U.S. Awards 2015  

Copyright © All rights reserved.
Failed to retrieve file