LCD -based Intelligent Burglar Alarm System User Guide
Contents
1. tP interference alert 0l remote control number 1 uery alarm panel The system can save up to the most recent 102 alarming alarming records records Syntax Press alarm panel query key of your keyboard then 9900 blinking status LED on and then press 9900 press 8 to scroll up and 0 to scroll down for records Example Screen shows 01 01 22 02 02 alarm which means alarm happened on 1 January 22 02pm at zone 2 5 Types of Alarm Zone 5 1 Definitions of Zones The alarm supports 99 distinguishable defense zones and they can be classified into one of the 8 Zone Types with their respective characteristics ID l NORMAL Defense The Panel only works on the arming status When Zone disarming there is no response 2 STAY Defense zone Can be shut off solely through the remote control AT HOME Defense Keypad to avoid the Infrared Detectors and other zone in room detectors from misinformation when master is resting at home 3 INTELLIGENT If the detector in the Defense zone is triggered only Defense zone once it will not immediately alarm But 1f being triggered once again within 30 seconds after the first triggering it will not alarm immediately 4 EMERGENCY No matter on arming or disarming status if detector is Defense zone triggered it will alert Usually used in connecting with Smoke Detectors Gas Detectors and emergency button etc 5 CLOSED Defense No matter arming or disarming status detectors w
2. disarm remote control is not allowed for extra security 1 is on and 0 is off the system default is off Example user needs to enforce to use keyboard Method one and then 151 press the then press Exit Setup Method two Forced disarm from panel keyboard Syntax L 15 0 1 After calling and connected to the panel from remote press 151 Turn on or off This set the alarm panel to sound for 5 seconds upon a kind of Interference Alert malicious attach from un authorized remote control or transmitter Syntax L 16 0 1 1 Keyboard password protection feature Syntax 17 0 1 Set number of ring tones before picking up Syntax C18 00 99 Restore factory setting Total System Reset Syntax Press and hold the ARM button on the keyboard and power on of same frequency meanwhile the alarm panel will display tP warning Example users need enable interference alert Method one and then press 161 press the then press Exit Setup Method two After calling and connected to the panel from remote press 161 To enable the password protect of keyboard System default password is 1234 defaults set to off Alarm panels will display keyboard locked when keyboard is locked Example keyboard users need to set the password protection Method one and then press 171 press the then press Exit Setup Method two After ca
3. 6 groups of phone number set up for calling notification that make sure you will not miss any happening of incident The LCD on panel displays clear system message and the location of alert together with the keypad on board LCD based Smart Burglar Alarm is an in dispensable choice of security solution for your properties and safety 1 2 System Features Large LCD English blue back light display voice prompt ease of use Can check status and call records from panel E Allow up to 99 wireless defense zones and 4 wired zones E Each can be defined as one of the 8 zone types including NORMAL STAY INTELLIGENT EMERGENCY CLOSED HELP SENIOR WELCOME and CHIME W Four sets of scheduled arm disarm function each time disarmed you can select the included period of time and different defense zone eliminating of need of the manual procedure realizing the beauty of automatic controls W6 group voice alarm phone number for alert calling different zones can dial a pre set telephone number and numbers saved inside EEPROM without lost upon power failure E Support ISD automatic voice mailbox for playback message upon alert Maximum length of voice message is 10 seconds Telephone phone long distance telephone control for arming disarming monitoring WE Wireless intelligent study coding compatible with PT2262 normal encoding and a 1527 encoding convenient and flexible for adding or reducing accessories Maximum support 150 remote contr
4. mode press the then press to exit Setup Method two After calling and connected to the panel from remote press 5620110701090000 Month 01 31 Day 00 23 Hour 00 60 minutes 00 59 Second Scheduled arm and To set the time for scheduled arm and disarm it allows set at disarm time setting most four group of time for arm and disarm Syntax Example set up the first group scheduled time to arm at 22 57 l Group 00 pm and disarm at 07 OO am this is valid for Monday number 01 04 Tuesday Wednesday Thursday and Friday of each week 4 AAAA Method one Scheduled time of enter the configuration mode and then press am BBBB 5 012200070012345 Example set up the second group scheduled time to arm at 12 00 and disarm at 13 00 pm this is valid for all 7 days of each week Method one enter the configuration mode and then 5702120013001234567 then press to exit Setup Method two After calling and connected to the panel from remote press57012200070012345 then press5702120013001234567 Scheduled disarmed time Number week press Scheduled arm and Used to set when the four group of zone to be controlled by disarm zones settings scheduled arm and disarm Example To set up the first group scheduled arm and disarm control 00 50 defense zone Method one Press enter the setup status and press 58010050 then press exit Se
5. I LCD based Intelligent Burglar Alarm System SM 5800 User Guide Ver 2 0 Table of Content Introduction 1 1 General Description 1 2 System Features Anatomy of the LCD based Intelligence Burglar Alarm 21 System Components and Usage Za System Setup yO Panel Setup 222 Connections of Cables Commands of LCD based Smart Burglar Alarm System 3 1 Operation upon receiving alarming call 3 2 Remote Operation using phone 3 3 Pre record Voice Message 3 4 Add Remote Control 3 5 Delete the remote control 3 6 Add detector 3 7 Delete detector Command Reference 4 1 Commands for Configuration 4 2 Commands of System Enquiries Types of Alarm Zone 6 1 Definitions of Zones 6 2 System default zone types are 6 3 Fitting parameters Guideline of Installation Sensors 6 1 Guideline for Installing Door or Window Sensor Nn ne yn WwW amp w 10 10 10 11 11 11 12 31 31 31 33 33 34 34 35 35 6 2 Guideline for Installing PIR Motion Sensor 35 7 Troubleshooting 37 1 Introduction 1 1 General Description LCD based Intelligent Burglar Alarm System is designed for both home and business use and is built on leading microprocessor technology This versatile system is also equipped with powerful features and user friendly interface as the most cost effective solution for security It has a built in siren with super high sound volume of 120 dB that is loud enough as an alert for most noisy environment The system allows at most
6. d please enter the password to unlock before other commands Query for voice To query the alarm panel currently saved to the first set to alarm phone number the Ninth group voice alarm phone number Press alarm panel query key of your keyboard then 3 1 9 J blinking status LED on the Panel and then press 31 the alarm panel LCD show 13812345678 means alarm panel s first set of alarm numbers are13812345678 Query password Used to query the current password of the alarm panel Press alarm panel query key of your keyboard then blinking status LED on and then press 50 the alarm panel LCD show 1234 Alarm panel your current password is 1234 Press to clear the screen press then press to exit the query mode Query the time for Query delay time for arm 00 99 Seconds delay arm Press alarm panel query key of your keyboard then Syntax blinking status LED on and then press 51 the alarm panel 51 LCD show 00 mean time for delay is 0 second Query delay time for To query the alarm delay time 00 99 Seconds Press alarm panel query key of your keyboard then blinking status LED on and then press 52 the alarm panel 52 LCD show 00 mean time for delay is 0 second Query siren sounding To query the siren sounding time 00 20 minutes when the Press alarm panel query key of your keyboard then blinking status LED on and then press 53 the alarm panel LCD show 01 mean time for delay is 1 minute Que
7. econds 1 arming 2 disarming 3 monitoring open 4 monitoring closed 5 siren on 6 siren off 7 Monitor the voice message in mailbox Hang up 3 2 Remote Operation using phone Dial into the alarm panel using telephone or cellular phone can carry out some operations remotely Upon the panel pick up your call and connected follow instruction played to input password default password is 1234 press the corresponding number on phone keypad for operation Alarm will automatically hang up call after invalid password failed for three times in succession 1 arming 2 disarming 3 monitoring open 4 monitoring closed 5 siren on 6 siren off 7 Monitor the voice message in mailbox Hang up enter the configuration mode 3 3 Pre record Voice Message Alarm panel will play a pre recorded voice message after the alarm call when a pre set phone number upon alarm To record customized message e Press Key to enter the configuration mode e Then press 19 speak your message at the panel for recording e System will record 10 Seconds and then automatically exit or press any key to end whenever your message end e Press then exit setup status 3 4 Add Remote Control Press key to enter the configuration mode e Syntax 07 00 99 to configure remote control Example 07 then press O1 to configure the Ist remote control Then press any key of the remote control to send a signal to t
8. es Syntax with the first group of phone zone the alarm panel LCD 58 01 04 show 00 99 means 0 99 zone are with 1 phone number group Query type wireless For query the zone types of 00 99 defense zone The alarm panel LCD show the name of type of zone Syntax detail about zone types can be referred to another section 60 00 99 of manual the word ON or OFF next to the zone type represents whether siren will sound upon alarming Query the type of For query the zone type of 51 54 wired zones Example Press alarm panel query key of your keyboard Syntax then blinking status LED on and then press 6151 to query 61 51 54 51 zone alarm type show NO means short circuit to alarm while show NC means open circuit to alarm Query remote To query if the remote operation is allowed it should show operation on off either ON or OFF Syntax 62 Query phone number To query the phone number assigned to zone 00 99 for Example Press alarm panel query key of your keyboard 63 00 99 then blinking status LED on and then press 6301 for zone 1 the alarm panel LCD show 123456 means these 6 group of phone numbers are assigned to 01 zone Query for the setting For query whether the alarm will play audible confirmation of alarm audible upon receipt of commands It shows either ON or OFF confirmation Syntax 1i Query the s
9. ethod two After calling and connected to the panel from remote press 5305 Set which defense zone will be controlled by remote control and from alarm panel keyboard Factory default is all remote control and keyboard can control all 00 99 zones Remark The 1 remote control represented by number 01 represents the alarm panel keyboard Example you want to set Ol remote control to control only 00 20 zone Method one Key to enter the configuration mode press 54010020 Method two After calling and connected to the panel from remote press 54010020 Example you want to set the alarm panel keyboard control 00 50 Defense zone Then press To exit Setup Method two After calling and connected to the panel from remote press 54 0050 audible for Set confirmation remote control operation Syntax 55 Remote control number 00 99 Coa 1 Set date and time settings Syntax 56 4 digits year 01 12 The 1 means on and 0 means closed the default is on Example set panel without sound when remote control number O1 is sending signal Method one Pressing to entering the setup and then press55010 then press to exit setup Method two After calling and connected to the panel from remote press 5501 0 Set the system date and time An example it is now 1 of July of 20119 Method one to enter the 5620110701090000 00 00am configuration
10. etting of For query whether the anti tampering of telephone line is anti tampering of set it shows either ON or OFF telephone line Syntax 13 Query sound volume Query for the volume level of siren it shows between 00 of siren 99 representing the 00 as lowest and 99 as highest volume Syntax 14 Query for the setting To query whether enforcing the disarm from keyboard of enforced keyboard upon alarming It shows either ON or OFF disarm Syntax 15 To query whether interference alert is set it shows either of interference alert ON or OFF Syntax 16 To query if the password protection feature is enabled it password protection shows either ON or OFF Syntax 17 C J Query of number of To query the number of ringing before the panel will pick rings before panel up incoming calls from remote pick up incoming call Example Press alarm panel query key of your keyboard Syntax then blinking status LED on and then press 18 it shows 18 08 means 8 rings 11 means 11 rings and so forth Query alarm panel The system can save up to the most recent 72 disarmed arm disarm records records Syntax Press alarm panel query key of your keyboard then 9901 blinking status LED on and then press 9901 press 8 to scroll up and O to scroll down for records Other indications as JP arm disarm from keyboard YC arm disarm from remote
11. he alarm panel panel beep twice means successful beep only once means the remote control has been configured before Alarm panel can configure up to 150 remote control of different addressing Upon completion press to exit the configuration mode press and then exit the configuration mode 3 5 Delete the remote control Press Key to enter the configuration mode e Syntax 1 08 00 99 to delete the remote control e Syntax 2 08 to delete all remote controls Example 08 then press 01 for deleting 1st remote control then if you want to delete Sth remote control press 08 instead of 01 Press to exit the delete remote control press and then to exit configuration mode 3 6 Add detector Press Key to enter the configuration mode Syntax 09 O0 99 to set the detector Example 09 then press 01 to configure Ist sensor then trigger the detector to send a signal to the alarm panel Panel beep twice means successful beep only once means the remote control has been configured before Alarm panel can configure up to 150 sensors of different addressing Upon completion press to exit the configuration mode press and then exit the configuration mode 3 7 Delete detector Press Key to enter the configuration mode Syntax 1 10 O0 99 to delete the detector Syntax 1 10 to delete all the detectors Example 10 then 01 to deleting Ist sensor If you want to delete the 6th detect
12. ill zone not alert even being triggered CHIME Zone No matter in what status when sensor with this zone 1s triggered a welcome door bell will be ring as notification 7 WELCOME Zone On disarming status when sensor with this zone is triggered a welcome voice message will be played HELP SENIOR This type of zone is for elderly safety no matter in Defense Zone what status the panel will alarm once sensor with this zone type is triggered 5 2 System default zone types are Normal Stay Intelligent Help Chime Welcome Emergency Senior 80 89 90 ft 924 93 99 5 3 Fitting parameters Input voltage DC9V 12V Standby currents lt 25mA Alarm current lt 450mA Wireless frequency 315 433 868 91SMHZ 2262 1 5 4 7M EV1527 300K E Backup battery NI HI AAA 6 DC7 24V E Alarm loudness 110dB Detailed parameters The alarm should be compatible with PT2262 PT2240 and EV1527 Using PT2262 encoding the resistance is recommended 1 5M 4 7M using with EV1527 encoding the resistance by 180K 470K It is advised to place jumpers randomly at AQ A7 for addressing of individual sensor better not to let them totally empty for security 6 Guideline of Installation Sensors 6 1 Guideline for Installing Door or Window Sensor 1 The surface for door sensor installation should be clean so door sensor can be attached to the door and frame firmly with double faced adhesive 2 Each door sensor is a pair of sensor and mag
13. lling and connected to the panel from remote press 171 The system default is 8 0 means the remote operation is not allowed and disabled Example the user needs to set up a number of rings before picking up to 6 Method one and then press 1806 Example the user needs to set off the remote number ring Method one and then press 1800 press the then press Exit Setup Method two After calling and connected to the panel from remote press 1806 or press 1800 System restore factory setting Method one and then press 9898 Method two After calling and connected to the panel from remote press9898 Remark This feature will restore all settings to factory default apart from the configuration of sensors and remote control Disconnect power to the alarm panel turned off the battery switch alarm panel then press and hold the alarm panel of ARM button while power on The system will respond with short beep slowly for 5 seconds then can release ARM button The system is now totally reset All configurations have been cleared all sensors and remote controlled are deleted and password is restored to original 1234 4 2 Commands of System Enquiries Press Query button on panel to enter the query mode alarm panel status LED is blinking Then put in commands as detailed in table below when finished Press and then press to exit the query mode Note In case keyboard password protection is enable
14. ls only the 5th group number Method one And then press6321215 Method two After calling and connected to the panel from remote press 6321215 After calling and connected to the panel from remote press Set audible Alarm panel will produce audible confirmation beep upon confirmation from receipt of signal from remote control 1 is on O is off and panel to on or off default is on Syntax Example users need to disable the audible confirmation 11 Jj Method one 0 1 then press 110 press the then press Exit Setup Method two After calling and connected to the panel from remote press 110 Enable or disable of Cut the phone cord will trigger the alert O is off and 1 on the anti tampering system defaults to closed of telephone cord Syntax Example user need to enable anti tampering of telephone 13 cord feature Loi l Method one Press Then press 131 then press to exit Setup Method two After calling and connected to the panel from remote press 131 Siren volume Valid value is from OO to 99 as largest system default is the adjustment largest Syntax Example users need to set volume to 50 14 Jj Method one 00 99 and then press 1450 press the then press Exit Setup Method two After calling and connected to the panel from remote press 1450 Upon alarming enforced to use only the panel keyboard to
15. n 7 Regular PIR motion sensor is for indoor use unless the specification stated otherwise Unless specifies otherwise most infra red detector are indoor use and not reliable to use outdoor 7 Troubleshooting Available Solutions 1 cannot dial for e no arming e do arming operation alarm e alerting phone unsettled e re set according to the e parts improperly installed specification e g sensors installed too far e coordinating the location of parts away e re coding e code no match 2 cannot e password input wrongly Retype Password or reset password long distance operation 3 no record e voice message not recorded e record voice message indication when alerting 4 remote control e coding un matched with the re learn the remote control keyboard out of Panel e change battery to correct type order e insufficient battery power or polish the surface of contact of battery contact no good battery e battery pieces poor contact contact the local dealer to change or voltage un matched with the matched remote control Panel keyfob 5 infrared detector low power e change to the same type battery out of order 6 Beam detector e Check power supply e Replaced with a working power out of order e Check if cables short circuit adapter e Check beam detector e Re cabling for perfect contact alignment e Make sure pair of sensors aligned by observing the indicators 7 siren without e siren plug or jack in short e repair
16. net The sensor A as in diagram should be installed on the fixed door frame and the magnet B as in diagram should be placed on the movable door with a distance not exceeding cm 3 Upon installed door sensor should be tested by open the door and check if the indicator on door sensor flashes for 1 second 4 Incase the door sensor is running out of battery the indicator should be kept lit as a low voltage notification 6 2 Guideline for Installing PIR Motion Sensor A Angle is nor A 70 deg to the Effective 2 2m floor Distance height 8 12 M x 1 Before use make sure the power switch of PIR motion sensors is at the ON position 2 Installation height is about 2 2 meters above ground and the optimized detection angle for most motion sensor is 90 degree The sensor should face the detected area with this consideration for best coverage It is advised to install with the face of motion sensor perpendicular to the most probable moving detection of people for the highest effective detection 3 Within coverage of detection there should be no any objects for obstruction 4 There should be no two infrared detectors in the same as they will possibly intervene with each other 5 Avoid the detector facing window cooling or warming machines or other appliances that cause the temperature changing sharply and thus cause false alarm 6 Most infra red detector needs about 5 minutes to heat up before READY for normal operatio
17. ol and 150 sensors W Unique black box features you can display most recent 72 disarmed records and 102 recent alarm recording Accurately shows the alarm time and zones number 2 Anatomy of the LCD based Intelligence Burglar Alarm 2 1 System Components and Usage ARM The system is at a fully ready status where all detectors are activated in a working state when the some events burglar fire gas leak etc happened and detected alarm system alarm right away In a ARM status the panel ARM light is on LCD screen show ARM is also on To activate using remote control press ARM key once To activate using keyboard on panel keyboard ARM keys once STAY ARM This is for partial arming of the alarm system when there are people at home only some of the selected sensors are activated and could be triggered by events In a STAY ARM status the panel ARM light is on LCD screen show Stay arm is also on To activate using remote control press Stay arm key once To activate using keyboard on panel keyboard STAY keys once DISARM All sensors are deactivated and will not be respond to any events In a DISARM status the panel ARM light is off LCD screen show DISARM is on To activate using remote control press DISARM key once To activate using keyboard on panel keyboard DISARM keys once EMERGENCY When an emergency occurs press emergency button on the remote or the button on panel to acti
18. on armed from the remote control or alarm panel the alarm system arm panel is set to delay O 99 before at the ready status of ARM The system default is OO seconds Syntax L 51 00 99 Second ime of Set the Set the t Syntax 52 00 99 Second Set length of Siren sound Syntax 53 00 20 Minute Set the scope of control of alarm panel and remote control Syntax 54 Remote control number 00 99 Starting defense area 00 99 End of defense zone 00 99 Example users need to set the delay time for 60 Seconds Method one Press key to enter the configuration mode press the 5160 then then press to exit setup Method two After calling and connected to the panel from remote a A z time of delay upon alarm it can be set to 0 99 seconds the system default is OO seconds Example the user needs to set the alarm delay time to 60 Seconds Method one Press Key to enter the configuration mode press the 5260 and then press to exit setup Method two After calling and connected to the panel from remote press 5260 Set alarm length of sounding when panel when the alarm could be set to 0 20 minutes factory default is 1 minute Example you want to make a siren sound 5 Minutes Method one Key to enter the configuration mode press the 53054 Then press To exit Setup M
19. or change plug or jack or sound circuit or broken line change the jack line siren out of order e use another siren to double check e closed siren by command e activate siren by command e positive and ground wires of reverse the wires to try adjust a siren reversed longer length of siren sounding 8 the transmission distance of detector to panel shorten 9 Alarm triggered continuously right after power up a nearby emitter is sending code Panel receiver stoppage standby battery of the Panel insufficient Phone cord is not connected but the phone alert function is enabled move one detector next to panel and try identify the interfering source and eliminate it check Panel power whether plugged well Either disable the phone alert function or connect the phone cord
20. ors use 06 instead of 01 Upon completion press to exit the configuration mode press and then exit the configuration mode 4 Command Reference This system supports two methods of configuration including the local keyboard telephone set Following are examples how instructions are given via one of the two methods of setting Example you want to change the first phone number for voice calling to 13899998888 Method 1 At the Keyboard Press to enter the configuration mode and then press 3113899998888 press the then press to exit configuration mode Method 2 By telephone set Calling into the alarm panel upon connected alarm panel will ask for password it is 1234 as the default then press and then press 3113899998888 press the then press to exit configuration mode Remark The status LED 1s lit on the panel to indicate at the configuration mode the status light is off upon exit Below is a table of all commands supported 4 1 Commands for Configuration Settings Keypad Sequence amp Parameters Set up voice alarm To set the Ist group to the 9th group of voice alarm phone phone number number 1 9 indicates that the first group to the Ninth group alarm number correspondingly Example If the user wants to set 13812345678 for the first set of voice alarm phone number Method one After you press the key to enter the configuration mode press the 3113812345678 Then press To exit Se
21. ry remote control For query of specific remote control and keyboard and keyboard assignments to zone 00 99 assignments to zone Press alarm panel query key of your keyboard then Syntax blinking status LED on and then press 5401 the alarm 54 00 99 panel LCD show 00 99 and remote control 1 means remote control 1 is controlling zone 00 99 press clear screen using 5402 for query remote control 2 and so on Query remote control For query the setting of remote control 00 99 for the audible confirmation audible confirmation to command Syntax Press alarm panel query key of your keyboard then 55 00 99 blinking status LED on and then press 5501 the alarm panel LCD show ON means remote control 1 is set to sound upon receipt of command Query the scheduled Used to query first to fourth set of scheduled time for arm time for arm and and disarm disarm Press alarm panel query key of your keyboard then Syntax blinking status LED on and then press 5701 to query the 57 01 04 first of scheduled arm and disarm the alarm panel LCD show Monday Tuesday 22 00 07 00 means schedule set as Monday and Tuesday 22 00 pm arm and 07 00 am disarm Query the zone For query the first to the fourth group scheduled arm and number with disarm scheduled arm and Press alarm panel query key of your keyboard then disarm blinking status LED on and then press 5801 for zon
22. tup L 3 1 9 Method two Phone number Remote calling into the alarm panel put in password initial 4 password 1234 when being asked then press the key hear the voice prompt and then press 3113812345678 then press to exit the remote setting status Remark For users using the telephone line extension you should dial a number such as 9 to pick up a dialing tone then with your command you should add to this number a So the completed command becomes 9 13812345678 Remark 7 8 9 group number for HELP SENIOR zone and panel will only dial these three groups number when that specific zone alarming Delete voice alarm Used to delete the first groups to the Ninth group alert phone phone number numbers Example If you want to delete the first set of telephone alarm number Method one After you press the key to enter the configuration mode press the 31 then press then press to exit Setup Method two After entering the telephone remote setting status press 31 Password Used to modify the user password the default user password 1s modification 1234 Example If you want to set up a new user password 4321 Syntax Method one 50 Four Press key to enter the configuration mode press the 504321 digital new Press the then press to exit setup password Method two After calling and connected to the panel from remote press 50432 1 Set delay for Up
23. tup Method two After calling and connected to the panel from remote press 58010050 Syntax sed to set when the four group of zone to be controlled by 58 Group scheduled arm and disarm number 01 04 Example To set up the first group scheduled arm and disarm 00 99 Defense control 00 50 defense zone zone begin the area Method one code 00 99 Press enter the setup status and press 58010050 then press Defense zone ends area code Method two After calling and connected to the panel from remote press 58010050 Set the type of To set 99 zone type 00 99 represents 0 99 zone number 1 8 defense zone represents one of the 8 zone type Syntax 1 NORMAL 60 00 99 2 STAY ARM zone number 4 3 INTELLIGENT 1 8 Type 4 EMERGENCY ol CLOSED CHIME WELCOME HELP SENIOR The last 0 1 represents O siren of panel produce no sound upon alarming while 1 is sounded Example Set zone number 2 as STAY zone type and siren not sound upon alarming Method one Key enters the configuration mode press 600220 Then press To exit Setup Method two After calling and connected to the panel from remote press 600220 Set mode of wired Set wired alarm zone to NO or NC The zone numbers of alarm zone 51 54 are wired defense zones system default is 51 54 are wired zones with NO mode Syntax 61 0 1 1 Set Remote Operation on or off S
24. vate alarm ae Stay Am Q 7 Urgent Remark If password on keyboard is enabled you need to enter password before other operations the initial password is 1234 2 2 System Setup 2 2 1 Panel Setup Alarm panel should be installed at a central location with best transmission to all the wireless sensors and accessories Keep the panel well away from large metal objects or household appliances with high frequency interference and avoid barriers such as concrete walls with metal frame inside and fire doors Alarm panel Antenna Time Speaker 2 2 2 Connections of Cables eee Backup battery ml ne ng j recharge switch O OG O LINEZ LINE SIREN POWER Power PSTN line 2 phone set Backup battery recharge switch PIR detector SEF Door contact 3 Commands of LCD based Smart Burglar Alarm System 3 1 Operation upon receiving alarming call After Panel alerts it will automatically dial the preset telephone number for three times until connected When the user picks up the phone a piece of pre recorded voice message will be played back immediately and let the receiver noted about the event Upon receiving the call it can also control the alarm panel remotely via the phone according to the command below User will not be asked for password upon connected and alarm will automatically hang up call within receiving any instruction within 20 s
25. yntax 62 1 0 1 Assign specific phone number to certain zone Syntax L 6 J 00 99 Defense zone begin the area code 00 99 Defense zone ends area code J Police group number 123456 zone number 51 54 J 0 means NO and 1 means NC Example Set 51 zone to NC Method one Key enters the configuration mode press 61511 Then press to exit Setup Method two 61511 Remark On the back pane of the alarm panel 51 zone 1 and labeled Z1 52 zone 2 and labeled Z2 53 zone 3 and labeled Z3 54 zone 4 and labeled 74 This enables or disables the remote operation of alarm panel using telephone System default is on Example turn off the remote setting function Method one and then press 620 then press To exit Setup Method two After calling and connected to the panel from remote press 620 System default is all 00 99 defense zone will make call from the first to sixth group phone number upon alarming Example user needs 00 10 to call the first second third set of numbers Method one and then press 6300101234 Method two After calling and connected to the panel from remote press 630010123 Example users need to 11 20 zone alarm the fourth the fifth and the sixth group number Method one And then press63 1 120456 Method two After calling and connected to the panel from remote press 631120456 Example User wants zone 21 cal
Download Pdf Manuals
Related Search
Related Contents
Capítulo II Requerimientos Eléctricos de la Estación Sensora de PYLE Audio PNVU500 User's Manual sM-Client Projekt - sM-Client Releases Superwinch 06302_06702 Installation Instructions ASSMANN Electronic AK-610518-000-I JVC Micro Component System UX-G48 Mode d`emploi - Leroy Merlin Version PDF - Argenteuil AutoCAD DWG to PDF Converter Help Copyright © All rights reserved.