Home
OPERATING INSTRUCTIONS
Contents
1. appears on the LCD dis play when replacement is needed To replace the battery remove the screw from the battery cover of the meter Remove the battery and replace with a new equivalent 9 volt battery P N 7000 1699A
2. range of 18 C to 28 C 64 F to 82 F for 1 year not including thermocouple error 0 3 rdg 1 C 50 C to 1000 C 0 5 rdg 1 C 1000 C to 1300 C 0 3 rdg 2 F 58 F to 2000 F Temperature Coefficient 0 1x specified accuracy per C 0 C to 18 C 28 C to 50 C Input Protection 60V dc or 24V rms ac maximum input voltage on any combination of input pins Reading Rate 2 5 times per second Input Connector Accepts standard miniature therm ocouple connec tors flat blades spaced 7 9mm center to center ENVIRONMENTAL Ambient Operation Range 0 C to 50 C 32 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F Relative Humidity 0 to 80 0 C to 35 C 32 F to 95 F 0 to 70 35 C to 50 C 95 F to 122 F GENERAL Display 3 digit liquid crystal display LCD with maxi mum reading of 1999 Battery Standard 9V battery NEDA 1604 IEC 6F22 Battery Life 100 hours typical with carbon zinc battery 200 hours typical with alkaline battery Dimensions 184mm H x 62mm W x35mm D Weight 10 60z 300g including holster Supplied Probe 4 foot type K thermocouple bead probe teflon tape insulated Maximum insulation temperature 260 C 500 F Probe accuracy 2 2 C or 0 75 of reading whichever is greater OPERATING INSTRUCTIONS Selecting the Temperature Scale Readings are displayed in either degrees Celsius CC or degrees Fahrenh
3. OPERATING INSTRUCTIONS DIGITAL THERMOMETER Con oF OFFSET MO i THERMOMETER INTRODUCTION This instrument is a portable 31 2 digit compact sized digital thermometer designed to use external K type thermocouple as temperature sensor Temperature indication follows National Bureau of Standards and IEC 584 temperature voltage tables for K type thermocouples One K type thermocouple is sup plied with the thermometer SAFETY INFORMATION It is recommended that you read the safety and op eration instructions before using the thermometer Designed to meet IEC 1010 1 CE EMC WARNING TO AVOID ELECTRICAL SHOCK DO NOT USE THIS INSTRUMENT WHEN VOLTAGES AT THE MEASUREMENT SURFACE EXCEED 24V AC OR 60V DC WARNING TO AVOID DAMAGE OR BURNS DO NOT MAKE TEMPERATURE MEASUREMENTS IN MICRO WAVE OVENS CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector The A symbol on the instrument indicates that the operator must refer to an explanation in this manual SPECIFICATIONS ELECTRICAL Temperature Scale Celsius or Fahrenheit user selectable Measurement Range i 50 C to 1300 C 58 F to 2000 F Resolution 1 C or 1 F 0 1 C or 0 1 F Accuracy Accuracy is specified for operating temperatures over the
4. eit F When the thermometer is turned on it is set to the temperature scale that was in use when the thermometer was last turned off To change the temperature scale press the C or F key Selecting the Display Resolution The thermometer allows two choices of resolution High resolution 0 1 C or 0 1 F Low resolution 1 0 C or 1 0 F To select the alternate display resolution press the corresponding 1 or 0 1 key The 0 1 resolution is applicable for temperature measurements below 200 C or 200 F HOLD Mode Pressing the HOLD key to enter the Data Hold mode the HOLD annunciator is displayed When HOLD mode is selected the thermometer holds the present readings and stops all further measurements Pressing the HOLD key again cancels HOLD mode causing the thermometer to resume taking measurements MIN MAX Mode Press MIN MAX once to begin recording MIN and MAX Press MIN MAX to select MIN or MAX Hold down for 2 seconds to exit MIN MAX function OFFSET ADJUSTMENT The OFFSET control is set at the factory to allow for the variations found in standard thermocouples By adjusting the OFFSET control you can optimize measurement accuracy for a particular thermocouple at a particular temperature Adjusting for Accurate Measurements 1 Connect the thermocouple to the input connector and turn the thermometer ON then press the 0 1 key to select the high display resolution 2 Place the th
5. ermocouple in a known stable tem perature environment at or near the temperature you wish to measure and allow the readings to stabilize 3 Slowly adjust the OFFSET control so that the ther mometer reading matches the temperature of the known environment Leave sufficient time be tween adjustments to allow for measurement lag 4 The calibration of the thermometer thermocouple combination is now optimized for measurements near the temperature measured in step 2 Resetting the OFFSET Control To return the OFFSET control to the factory setting without having to recalibrate the thermometer per form the following procedure 1 Connect a thermocouple that is in good working order to the input that is to be adjusted 2 Place the thermocouple in an ice water bath and allow the readings to stabilize 3 Slowly adjust the OFFSET control until the ther mometer reads 0 C 32 F Probe Detector The red LED will be ON when no K type thermcouple probe is inserted into the TEMP input of the meter and will be OFF after K type thermocople probe is inserted If the red LED stays ON when thermocouple probe is attached check the thermocouple probe which might be damaged OPERATOR MAINTENANCE WARNING TO AVOID POSSIBLE ELECTRICAL SHOCK DISCONNECT THE THERMOCOOUPLE CONNECTORS FROM THE THERMOMETER BEFORE REMOVING THE COVER Battery Replacement Power is supplied by a standard 9 volt battery NEDA 1604 IEC 6F22 The
Download Pdf Manuals
Related Search
Related Contents
Stages, mode d`emploi - 10 du mat WILFLEX ® ARTIST PLUS WHITE #11122WHT User Manual Owners manual Dock shelters OtoStat User Manual Ricevitore digitale Terrestre sRT 5301 Manhattan 160858 speaker set View DISTO PlusDraw manual realización de una prueba de glucosa en sangre - Hecht Copyright © All rights reserved.