SAS to SAS/SATA II JBOD Subsystem User Manual
Contents
1. Power On Fail Indicator Power On Off Switch AC Power Inlet Plug Male The panel of the Power Supply Fan Module contains the Power On Off Switch the AC Inlet Plug and a Power On Fail Indicator showing the Power Status LED indicating ready or fail Each fan within a PSFM is powered independently of the power supply within the same PSFM So if the power supply of a PSFM fails the fan associated with that PSFM will continue to operate and cool the enclosure When the power cord connected from main power source is inserted to the AC Power Inlet the power status LED becomes RED When the switch of the PSFM is turned on the LED will turn GREEN When the Power On Fail LED is GREEN the PSFM is functioning normally User Manual ETE SAS to SAS SATA II J BOD Subsystem NOTE Each PSFM has one Power Supply and one Fan PSFM 1 has Power 1 and Fan 1 and PSFM 2 has Power 2 and Fan 2 When the Power Supply of a PSFM fails the PSFM need not be removed from the slot if replacement is not yet available The fan will still work and provide necessary airflow inside the enclosure In replacing the failed PSFM refer to section 3 2 2 of this manual NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the Power Supply will be powered
2. 6 Insert the disk tray into the subsystem 20 User Manual SAS to SAS SATA II JBOD Subsystem 2 3 Connecting the J BOD Subsystem 2 3 1 Connecting to SAS HBA The Enclosure supports SAS interface which provides fast 300MB data transfer rate using SAS phy The package comes with one SAS cable for single JBOD controller module or two SAS cables for redundant J BOD controller modules Attach one end of the SAS cable to the SAS IN Port and the other end to the host bus adapter s HBA external SAS connector or to the SAS Switch The host bus adapter is installed in your Host computer system 2 3 2 Connecting to RAI D Subsystem Attach one end of the SAS cable to the SAS IN Port of the JBOD controller module and the other end to the SAS Expansion Port on the RAID controller of RAID subsystem If configured in redundant mode connect the other SAS cable to the SAS IN Port of the other JBOD controller and the other end to the SAS Expansion Port on the other RAID controller of RAID subsystem User Manual 21 SAS to SAS SATA II J BOD Subsystem Chapter 3 Maintenance 3 1 Upgrading Firmware Upgrading Firmware Trough Terminal NOTE It is important to stop O access to J BOD subsystem during firmware upgrade NOTE Upgrading the firmware must be done in both J BOD Controllers if the J BOD Subsystem has redundant J BOD Controllers 1 Please use the null modem cable RJ 11 to DB9 and to connect J BOD Monitor Port
3. A O a E E EE A ee ener ene 22 3 2 Replacing JBOD Subsystem COMPONENMS ccesesessesesssesscsssssesscsessseesssesesessesssnssesesessesscesesescseseeseseseseeseseees 24 3 2 1 Replacing JBOD Controller Module cocoiomsiinil india 24 3 2 1 1 Replacing Controller Module with Plate COVES oooococococociccononocconononocncnonoonononono nooo corno no crcnannronnos 25 3 2 2 Replacing Power Supply Fan MOdule nu csessssesssesssscscsssssssesessssssssessssesecsssssessssesesessesssesesessesseesees 26 3 2 2 1 Replacing Power Supply Fan Module with Plate COvVerT ocooccocicincocinononconononncnoncnnonononrororononoos 27 E User Manual SAS to SAS SATA II JBOD Subsystem Chapter 1 Introduction The 24 bays EPI Ca J BOD Subsystem The EPICa EP 2243 D S3S3 is a 19 inch 2U rackmount J BOD unit It comes with 24 hot swappable bays and is a versatile SAS SATA II Disk Expansion system ideal for high capacity and scalability storage in most popular OS environments It designed to fit in with the environments which needed highly reliable and relentless data growth Based on 3Gb SAS Channel host interfaces the EP 2243 D S3S3 Supporting the choice of SAS and SATA II drive configurations to deliver the best cost performance index with higher bandwidth User Manual ENS SAS to SAS SATA II J BOD Subsystem 1 1 Features Highest Density Available 2U chassis with 24 bays carriers Support the latest 2 5 enterprise class SAS SATA disk dr
4. JBOD Controller 1 JBOD Controller 2 n Bier l ue T a A aa Er l Y L E dl e ll O ENEE OSO ae a Se aor MEE Power Supply Power Supply Fan Module 1 Fan Module 2 O B User Manual SAS to SAS SATA II JBOD Subsystem 1 4 3 JBOD Controller Module The EPICa JBOD subsystem includes a single or dual 3Gb SAS to SAS SATA II J BOD Controller Module tl a OA AAA Eaa OA Fy Pr Soar E y JBOD Controller Module User Manual 9 SAS to SAS SATA II JBOD Subsystem 1 4 3 1 JBOD Controller Panel SAS Expansion Port i ars IMA cnn e cs 2032022 FOO SL OSS 0 0 0 C IA OO II A el Link LED RS 232 Port SAS In Port Activity LED Use to connect to SAS HBA or to RAID subsystem s SAS Expansion Port SAS Expansion Port Use to connect to the SAS In Port of another J BOD subsystem Use to upgrade the firmware of the BOD RS 232 Port controller Connect the RJ 11 to DB9 serial cable to your system s serial port LinkLED Green Indicates expander has connected or linked Activity LED Blinking Indicates the expander is busy and being Blue accessed META User Manual SAS to SAS SATA II JBOD Subsystem 1 5 Power Supply Fan Module PSFM The EPICa JBOD subsystem contains two 400W Power Supply Fan Modules All PSFMs are inserted into the rear of the chassis 1 5 1 PSFM Panel is i GA Al
5. and PC COM1 Port or change to other COM Port as necessary 2 Open Windows HyperTerminal Program Connect using COM1 COM Port used in Step1 Baud Rate 115200 n 8 1 Flow Control None 3 Press the Enter key and the password prompt will be displayed 4 Key in the password Default password 00000000 to login to CLI 5 At CLI prompt input the command to update firmware a CLI gt er datl b CLI gt er code NOTE er code is the command to erase flash firmware code er dati is the command to erase CFG data code fl code is the command to update flash firmware code bin file fl dat1 is the command to update CFG data code rom file Make sure you have both files before updating CLI gt fl dati d Select Function menu to transfer CFG data rom file Function gt Transfer gt Send File gt Browse 3 Open and select the rom file for example 8010 mfgdat1 090608 firmware folder location Select 1K Xmodem Protocol to send firmware file Only need about 15 seconds to finish sending firmware file If not please repeat steps C and D again 77 User Manual SAS to SAS SATA II JBOD Subsystem e CLI gt fl code f Select Function menu to transfer firmware file Function gt Transfer 3 Send File 3 Browse 3 Open and select the bin file for example 8010 05 63 1 32 090526 bin from firmware folder location Select 1K Xmodem P
6. on This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work 12 User Manual SAS to SAS SATA II JBOD Subsystem 1 6 LCD Display Panel 1 6 1 LCD Panel LED Power LED Power Fail LED Fan Fail LED Over Temperature LED Voltage Warning LED Reserved for RAID Subsystem Power LED Green indicates power is ON If one of the redundant power supply unit fails this LED will turn to RED and alarm will sound Power Fail LED Turn RED when fan 1 or 2 fails or Fan Fail LED speed is lower than 500 RPM If disk temperatures exceed 60 C E the Over Temperature LED will turn RED and alarm will sound Over Temperature LED An alarm will sound if detected voltage in the controller is Voltage Warning LED 9 9 abnormal and LED will turn RED User Manual FE SAS to SAS SATA II J BOD Subsystem 1 6 2 LCD Panel Function Buttons Up and Down Use the Up or Down arrow keys to go through the information on the OM BUTTONS hd LCD screen This is also used to move between each menu A This is used to enter the option Select button you have selected l Press this button to return to the 14 User Manual SAS to SAS SATA II JBOD Subsystem 1 7 Drive Carrier Module 1 7 1 HDD Status Indicators XA E E E E BEEEETEL ET Fault LED Activity LED o This LED will blink blue when the hard drive is being Disk Activit
7. SAS to SAS SATA II J BOD Subsystem User Manual SAS to SAS SATA II JBOD Subsystem Table of Contents Chapter 1 Gg og oo 0 a 0 9 urnas cansarse 3 LE GET IRA ease A A E E EE 4 12 Technical SO SGI a ONG A A A 5 13 Unpacking The JBOD SUDSYSTEI cecilia 6 1 4 Identifying Parts of the JBOD Subsystem Qu ec sessssessesesessesesssscsscsesessesecsssescesessssessssesessssesecseacssesesnsseeeeneans 7 LA SON NOW teats etc tas 7 TAZ Ainas 8 14 gt JBOD C NTrONEr MOS 9 LAS JBOD Controller Panel anaconda eN e S aa NEEE e EA aaien 10 LS Power Supply Fan Module PRIM entire 11 EL PORNP O eE E E E E E EE 11 LS SB DD Ey Peon 13 LOL ECP Panel cl B en ae E E E E E E 13 t62 LCD Panel Function CUA vesical 14 Li Dive Camier Mode nono E E A E tee 15 LA ADI aN CAOS ds 15 Chapter 2 Installation of J BOD Subsystein cssssssscccccccccessssssscccceeeees 16 A taste ceca cette EA E A eae 16 22 DIS DINE Yah 1 2 1 g eeeeeecee reer meee E EA 17 2 2 1 Installing a SAS Disk Drive in a Disk Tray csesesesssessesessscssssssesssscsesessssesessssssessssesesessesssessseessesessees 17 2 2 2 Installing a SATA Disk Drive Dual Controller Mode in a Disk TraY ococicccinicincnononmmmmms 19 23 Connecting the JBOD Subsy St Mislata 21 Zor COE to SAS AA 21 2 3 2 Connecting to RAID SUBS Minato lila 21 Chapter 3 Maintenance oooeeeeeeeceesssssssssssscccccccceeeeeeeeeesssssccccccceeeeeeeseessssssseesssscceee 22 SL UDa amna
8. ake sure the Power On Off Switch is on Off state U bu N e 6 Insert and slide the new PSFM in until it clicks into place I MPORTANT When the subsystem is online and a Power Supply fails and the replacement Power Supply module is not yet available the failed Power Supply Module can be replaced with the Plate Cover This is to maintain proper airflow within the enclosure Refer to next section When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 7 Connect the power cord to the AC Inlet Plug of PSFM 8 Tighten the thumbscrews of the PSFM 9 Turn on the Power On Off Switch of the PSFM NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the Power Supply will then be powered on This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work 26 User Manual SAS to SAS SATA II JBOD Subsystem 3 2 2 1 Replacing Power Supply Fan Module with Plate Cover When replacing a failed power supply fan module PSFM with Plate Cover please follow these steps Turn off the Power On Off Switch of t
9. he failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the failed PSFM Pull out the defective PSFM Insert the PSFM Plate Cover carefully Se A a Power Supply Fan Module Plate Cover User Manual EN
10. ingle Controller Mode 1 Press the Tray Open button and the Disk Tray handle will flip open r E E 4 a d q d 4 PERE LL EET fT Tray Open Button 2 Pull out an empty disk tray Pull the handle outwards to remove the tray from the enclosure 3 Place the hard drive in the disk tray Make sure the holes of the disk tray align with the holes of the hard drive User Manual ETA SAS to SAS SATA II JBOD Subsystem 4 Install the mounting screws on the bottom part to secure the drive in the disk tray 5 Slide the tray into a slot 6 Press the lever in until you hear the latch click into place The HDD Fault LED will turn green when the subsystem is powered on and HDD is good 18 User Manual SAS to SAS SATA II JBOD Subsystem 2 2 2 Installing a SATA Disk Drive Dual Controller Mode in a Disk Tray 1 Remove an empty disk tray from the subsystem 2 Prepare the dongle board and two screws 3 Place the dongle board in the disk tray Turn the tray upside down Tighten two screws to secure the dongle board into the disk tray User Manual 19 SAS to SAS SATA II JBOD Subsystem 4 Place the SATA disk drive into the disk tray Slide the disk drive towards the dongle board 5 Turn the disk tray upside down To secure the disk drive into the disk tray tighten four screws on the holes of the disk tray Note in the picture below where the screws should be place in the disk try holes
11. ives High Availability Single or dual SAS J BOD controller module Each SAS JBOD controller module consist of three mini SAS 4X port Power Supply Power Supply and cooling system contained in 1 module for efficient cooling Two 400W redundant hot swappable power supplies Enclosure Incorporates a cableless design for maximum signal integrity SES Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions Enclosure monitoring S E S support for standard enclosure management System LED indications Fan speed monitoring Power supply monitoring System voltage monitoring System temperature monitoring System alarm 24 User Manual SAS to SAS SATA II JBOD Subsystem 1 2 Technical Specifications ___ __ ____ _ A A E _ _ _ _ __ _ _ lal _ _ _ ll _ lll __ _ _ __ _ _ z _ ____ _______ ____ __________________________4 A S Controller Single Redundant Host Interface One 4x mini SAS 3Gb s Two 4x mini SAS 3Gb s Disk Interface SAS 3Gb or SATAII SAS expander gt Two 4x mini SAS 3Gb s Four 4x mini SAS 3Gb s Enclosure Platform Rackmount s i i i iOCOOOO Form Factor 2U0 ofHotSwap Twenty four 24 2 5 Small Form Factor SFF trays Disk Status Access FailLED Backplane SAS SATA II Single BP AT 400Wx2wPFC a 22 Monitor Port a Power AC 90V 264V F
12. new one IMPORTANT When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 4 Tighten the thumbscrews on the sides of the JBOD Controller Module case r PRI A 24 User Manual SAS to SAS SATA II JBOD Subsystem 3 2 1 1 Replacing Controller Module with Plate Cover When replacing a failed JBOD Controller Module with Plate Cover please follow these steps 1 Loosen thumbscrews of the failed JBOD Controller Module drawer 2 Use the Controller Module handle to remove the failed JBOD Controller Module drawer from the subsystem 3 Insert the JBOD Controller Plate Cover J BOD Controller Module Plate Cover l EAN When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature User Manual 25 SAS to SAS SATA II J BOD Subsystem 3 2 2 Replacing Power Supply Fan Module When replacing a failed power supply fan module PSFM please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the PSFM Use the handle to pull out the defective PSFM Before inserting the new PSFM m
13. rotocol to send firmware file Only need about 15 seconds to finish sending firmware file If not please repeat steps E and F again NOTE If the JBOD Subsystem has redundant JBOD Controllers remove the serial cable RJ 11 to DB9 from RS232 Port of J BOD Controller 1 and insert in the RS232 Port of J BOD Controller 2 and then repeat steps 3 to 6 to upgrade J BOD Controller 2 After upgrading both J BOD controllers power cycle the J BOD Subsystem Then login to CLI to verify J BOD firmware version NOTE If J BOD Subsystem has single J BOD Controller you can use the xr command to restart the J BOD Controller without needing to power cycle g Re login to JBOD CLI h Use sy command to verify JBOD firmware version CLI gt sy i If needed the xr command can also be used to restart the J BOD controller Normally used in single JBOD Controller mode CLI gt xr User Manual PES SAS to SAS SATA II J BOD Subsystem 3 2 Replacing J BOD Subsystem Components 3 2 1 Replacing J BOD Controller Module When replacing a failed J BOD Controller Module please follow these steps Loosen the thumbscrews on the sides of the JBOD Controller Module drawer 2 Use the Controller handle to pull out the defective JBOD Controller Module drawer 3 Insert and slide the new JBOD Controller Module in Note that it may be necessary to remove the old defective JBOD Controller Module from the drawer case and install the
14. ull Range 8A 4A 47Hz 63Hz Environment SS LL LLL LLL LLL LL LLL LLL LLL EL EL LL LL EL LLL EL EL EL a a a a A A A A A A A A A A A A A A A A A A Operating 10 C 40 C 50 F 104 F Physical 559 L x 483 W x 88 H mm E UER REE TOE OE AE E EAO E SS SE E E User Manual so SAS to SAS SATA II J BOD Subsystem 1 3 Unpacking the J BOD Subsystem The shipping package contains the following JBOD Subsystem Unit Two 2 power cords One serial cable RJ 11 to DB9 Note Two serial cables for dual J BOD controllers One external Mini SAS cable SFF 8088 to SFF 8088 Note Two mini SAS cables for dual J BOD controllers One 1 JBOD Controller Module Plate Cover NOTE For Dual RAID Controller One 1 PSFM Plate Cover User Manual NOTE If any damage is found contact the dealer or vendor for assistance 6 User Manual SAS to SAS SATA II JBOD Subsystem 1 4 Identifying Parts of the J BOD Subsystem The illustrations below identify the various parts of the expansion chassis 1 4 1 Front View Smart LCD Panel O P TIA A ae eee Disk Trays Slot 1 24 Right to Left User Manual Ea SAS to SAS SATA II J BOD Subsystem 1 4 2 Rear View Single BOD Controller JBOD Controller Module 6600060000005 N Cl pe m E Se EJ i Ll i lt E o ME lt ora DL oe ee me Power Supply Power Supply I Fan Module 1 Fan Module 2 Dual J BOD Controller
15. y Indicator 2 cessed Green LED indicates power is on and hard drive status is good for this slot If there is no hard drive the LED is Disk Status Indicator Red The fault indicator depends on the RAID card or RAID Controller definition User Manual a5 SAS to SAS SATA II J BOD Subsystem Chapter 2 Installation of J BOD Subsystem 2 1 Powering On 1 Plug in the power cords into the AC Power Input Socket located at the rear of the subsystem Power On Off Switch D Y wane Oo y PN el 1 Y os Xe Lo TOi 9 1 ER MOI A El 7 o d MU ma 01 AAA y u AC Power Input Socket NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system will automatically select voltage 2 Turn on each Power On Off Switch to power on the subsystem 3 The Power LED on the front panel will turn green 16 User Manual SAS to SAS SATA II JBOD Subsystem 2 2 Disk Drive Installation This section describes the physical locations of the hard drives supported by the Subsystem and give instructions on installing a hard drive The subsystem supports hot swapping allowing you to install or replace a hard drive while the subsystem is running 2 2 1 Installing a SAS Disk Drive in a Disk Tray NOTE These steps are the same when installing SATA disk drive in S