Home
Acmeda Installation Manual Template
Contents
1. 4 STRATCO ACMEDA AMBIENT EXTERNAL BLINDS PRECISION IN MOTION AMBIENT BLINDS WINDSOR WIRE GUIDED SEMI RESTRAINED Lu UO i lt Cn Z 4 JTRATCO CONTENTS This manual is to be read in conjunction with the Product Specifications amp Assembly manual SECTION NO DESCRIPTION PAGE NO SECTION 1 ITEMS REQUIRED 1 1 SECTION 2 INSTALLATION 2 1 PART A PREPARING INSTALLATION SPACE 2 1 PART B BRACKET BOX INSTALLATION 2 3 PART C WIRE GUIDE INSTALLATION 2 4 PART D BLIND INSTALLATION 2 8 PART E BOX COVER INSTALLATION FOR BOX 120 SYSTEM ONLY 2 10 PART F TENSION GUIDELINES 2 12 SECTION 3 TROUBLESHOOTING 3 1 DISCLAIMER INTRODUCTION This Installation manual has been produced by Acmeda to supply the necessary information for safe and correct installation of this system INSTALLERS RESPONSIBILITY Before installing please read amp ensure you understand the safety information and installation instructions as defined in this installation manual e If you do not fully understand these instructions contact Acmeda for clarification before installing The Installer is responsible to ensure that all installation personnel have been adequately trained on the safe amp correct installation and operation The Installer is responsible to ensure that a Job Safety Analysis or Safe Work Method Statement is completed prior to installation to identify hazards to determine appropria
2. I l P I l 1 l ND l l l I Page 1 2 EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA Copyright 2013 All Rights Reserved Acmeda International Group SHECISION JW MOTION Minimum ga clearance above blind roll 6mm 103mm BLIND ROLL ADJUSTMENT RANGE 13mm BLIND WIDTH W NOTE For Top Fix Installations allow 5mm from the wall to the edge of the bracket to provide clearance for weight bar end caps Ensure brackets can be installed into a structurally supporting substrate This may mean the installer needs to prepare space prior to commencement of installation EXTERNAL WIRE GUIDE Installation Manual September 2013 P 2 1 ape Copyright 2013 All Rights Reserved Acmeda International Group A C M E DA A STRATCO STEP 2 CHECK VERTICAL amp HORIZONTAL INSTALLATION DIMENSIONS VERTICAL DIMENSIONS Check if top of installation space is level f H1 H2 corrective actions may need to be considered prior to installation HORIZONTAL DIMENSIONS W1 If W2 gt W1 W1 Blind Width proceed to Section C W2 If W2 lt W1 see table for limits MES aa MnO ae A Bx 120 eos 2mm If X and Y are within limits as indicated in the above table then installation can be completed using W1 as Blind Width If not consider further actions for squaring the installation space e g packing or alternative bracket selection EXTERNAL WIRE GUIDE Installat
3. E ADJUSTABLE STOP TO WIRE GUIDES FOR BOX 120 SYSTEM ONLY 5mm min NOTE Ensure that a minimum clearance of 5mm is left between the bottom of the Adjustable Stop and bottom of the Box to prevent the weight bar from twisting EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA P 2 7 ape Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION A STRATCO STEP 1 INSERT CONTROL END FIRST THEN SWING IDLER END INTO ADAPTOR GEAR CONTROL Ensure Idler Pin Locks into Adaptor STAR HEAD MOTOR FOR STAR HEAD MOTOR ONLY Remove retaining screw from the lock ring before inserting blind as shown above NOTE Ensure screw is safely stored as it will need to be re inserted EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA Page 2 8 Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION A STRATCO STEP 2 REPLACE amp SECURE RETAINING SCREW INTO LOCKING RING STAR HEAD MOTOR ONLY Screw until tight in order to lock the Motor in position STEP 3 INSERT FLOATING END CAPS INTO END CAP HOUSING Before applying tension to wire guides insert end cap float If more clearance space is required lift the weight bar at one into weight bar end caps end to insert the second float NOTE If ballast is required insert prior to fitting end cap For external applications ensure ballast is corrosi
4. RACKET L approximately 20mm for tensioning Allow 5 10mm f before tensioning NOTE Ensure both Terminals are attached to brackets FLOOR FIX ROUND EYE PLATE LL i Remove 1 Nut amp 2 ii Thread Turnbuckle iii Remove Pin amp Clip iv Position Jaw over v Replace amp Secure Washers From Stud Set onto Terminal Round Eye Plate Pin amp Clip Terminal NOTE Ensure both Terminals are attached to Round Eye Plates EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA P 2 Sees Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION A STRATCO STEP 3 INSERT WIRE GUIDE FLOAT ONTO WIRE Feed Floating End Cap onto Wire at both ends Allow End Cap to Slide along wire NOTE Repeat on opposite side STEP 4 ADD ADJUSTABLE STOP FOR BOX 120 SYSTEM ONLY NOTES e Ensure Adjustable Stop is inserted after the Wire Guide Float e Do not tighten at this step Repeat on opposite side EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA P 2 daah Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION A STRATCO STEP 5 SECURE WIRE TO TOP TERMINAL Insert Wire through terminal Measure amp cut wire approximately Tighten grub screw securely to retain 5 10mm above terminal wire ensure thread of grub screw does not strip STEP 6 ADJUST amp SECUR
5. d does not fully open jams incorrect terminal then reposition Refer to Part C Step 1 of this document for wire guide positioning details Incorrect motor stop limits used Refer to motor instructions to reset stop limits neven weight bar Blind roll is not level thus weight bar PE appears uneven Check blind roll when the blind is fully raised If ripples are Blind has been operated in excessive evident on roll open blind fully without the presence of wind conditions wind to allow the blind to track down evenly Raise and lower blind a number of times to check operation Ensure fabric is assembled straight onto tube and weight Fabric is not installed straight bar EXTERNAL WIRE GUIDE Installation Manual September 2013 A C M E D A P od sec Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION ACMEDA PRECISION IN MOTION 4 VY oe aA mz DR ibis pes Sars TAAN Scan this QR code with your smart phone to find a Stratco near you QUEENSLAND NEW SOUTH WALES AUSTRALIAN CAPITAL TERRITORY VICTORIA SOUTH AUSTRALIA WESTERN AUSTRALIA NORTHERN TERRITORY polos ob PLEASE NOTE Photo s for illustration purposes only f All brands and logos images accompanied by or are trade marks of Stratco Australia Pty Limited Copyright June 2014 BROCAMB 25
6. ill and rotating bottom nut as supporting Swage Terminal to ensure contact with bracket required No Of Rotations indicated tension is maintained above repeat on other terminal 1 Pull Swage Terminal down and hand 2 Apply tension by holding Swage 3 While holding the Turnbuckle Secure tighten Turnbuckle to remove slack Terminal and rotating Turnbuckle as both top and bottom nuts to ensure the required No Of Rotations indicated system is locked ensure to only lock one above at a time NOTE Repeat on opposite side EXTERNAL WIRE GUIDE Installation Manual September 2013 P 2 12 abe Copyright 2013 All Rights Reserved Acmeda International Group A C M E DA S TRATCO SECTION 3 TROUBLESHOOTING PROBLEM CAUSE SOLUTION 1 Ripples along sides of fabric l This occurrence is inherent to roller systems and is more Blind rolled up for an extended period prevalent in some fabrics Leave blind down for 1 4 hours of time l most ripples should disappear i Refer to Product Specs Not enough weight in weight bar Installation is not square Check blind roll is installed level Fabric permanently damaged due to inadequate handling during assembly Replace fabric and ensure it is handled with care transportation installation or use 2 Check if wire guide fixing at floor base are positioned in line Position of wire guides at base is with the Top Terminal If fixing is too far inwards of the Blin
7. ion Manual September 2013 AC M E DA P 2 2 ape Copyright 2013 All Rights Reserved Acmeda International Group ee e OLIN STEP 1 FIX BRACKETS TO WALL CEILING USING APPROPRIATE FIXINGS TO SUIT APPLICATION OPEN BLIND SYSTEM FACE FIX TOP FIX NOTE Ensure brackets are installed aligned and level Refer to deductions for bracket positioning BOX 120 SYSTEM Box 120 System can be fixed to the wall in the centre prior to fixing the brackets to ensure Box is level FACE FIX TOP FIX NOTE Ensure Bracket Spacers are used with Box 120 System EXTERNAL WIRE GUIDE Installation Manual September 2013 P 2 3 abe Copyright 2013 All Rights Reserved Acmeda International Group A C M E DA A STRATCO PART C WIRE GUIDE INSTALLATION STEP 1 MARK amp SECURE BOTTOM WIRE GUIDE FIXING TO WALL OR FLOOR OPEN BLIND SYSTEM BLIND WIDTH W BLIND DROP D X 2 Brackets NOTE Dimensions refer centre of wire and apply to both Face Fixing and Floor Fixing installations BOX 120 SYSTEM BLIND WIDTH W BLIND DROP D I X 2 Plates f N uD NOTE Dimensions refer centre of wire and apply to both Face Fixing and Floor Fixing installations EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA P 2 4 age Copyright 2013 All Rights Reserved Acmeda International Group e ANGLIA A STRATCO STEP 2 ATTACH TERMINAL TO WALL MOUNTING BRACKET FACE FIX WALL MOUNTING B
8. on resistant and is compatible with aluminium EXTERNAL WIRE GUIDE Installation Manual September 2013 P 2 a Copyright 2013 All Rights Reserved Acmeda International Group A C M E D A PRECISION IN MOTION A STRATCO PART E BOX COVER INSTALLATION FOR BOX 120 SYSTEM ONLY STEP 1 SWING BOX COVER INTO PLACE Ensure Cover clips to tab IF the lip of the cover is not location use a pair of pliers to adjust the locking feature up or down as required EXTERNAL WIRE GUIDE Installation Manual September 2013 P 2 1 ee Copyright 2013 All Rights Reserved Acmeda International Group 9 A C M E DA A STRATCO STEP 2 FIX COVER WITH SCREW OR RIVET OPTIONAL EXTERNAL WIRE GUIDE Installation Manual September 2013 AC M E DA P 2 11 abe Copyright 2013 All Rights Reserved Acmeda International Group PRECISION IN MOTION A STRATCO PART F TENSION GUIDELINES To complete the installation ensure adequate tension is applied to the wire guides 40kg of tension is recommended for the system If a suitable tension meter is not used the chart images below provide a guide on how to apply a nominal tension of 40kg No of Rotations No of Rotations Face Fix Floor Fix 1 Pull Swage Terminal down to remove 2 Apply tension by holding Swage 3 Tighten and lock top nut while slack and hand tighten bottom nut until Terminal st
9. te risk control measures and to implement the control measures e The Installer is responsible to ensure that supporting structures are sound and can adequately support the load e The Installer is responsible to ensure that the devises used to anchor the product to the supporting structure are suitable for the application SAFETY INFORMATION e Ensure Job Safety Analysis Safe Work Method Statement is completed and actions to reduce risks are implemented e Ensure that electrical works are done only by a LICENSED ELECTRICIAN DO NOT modify any of the components of this system PERSONNEL REQUIREMENTS Only suitably trained qualified personnel should undertake installation DISCLAIMER Acmeda has used reasonable care in preparing the information included in this document but makes no representations or warranties as to the completeness or accuracy of the information Information is supplied upon the condition that the persons receiving the information will make their own determination as to its suitability for their purposes prior to use Acmeda assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein Acmeda reserves the right to make changes without further notice to any products to improve reliability function or design COPYRIGHT COPYRIGHT ACMEDA 2013 All rights reserved No part of this document may be reproduced or utilised in any means by any means elec
10. tronic or mechanical including photocopying recordings or by any information storage or retrieval system without the express permission from Acmeda 4 JTRATCO SECTION 1 ITEMS REQUIRED TOOLS REQUIRED Saw Saw Drill Screw Driver Philips Head amp Flat Head Jaw Pliers Allen Key Set Mallet Scissors Punch tool template Measuring Tape Pencil ADDITIONAL ITEMS REQUIRED NOT SUPPLIED To assemble an EXTERNAL WIRE GUIDE the following non stocked items are required e Fixings for mounting brackets hardware Ensure appropriate fixings are used to suit application EXTERNAL WIRE GUIDE Installation Manual September 2013 P 1 1 aps Copyright 2013 All Rights Reserved Acmeda International Group ACMEDA PRECISION IN MOTION A STRATCO Check that you have all required blind items 1 Brackets 3 Complete Blind 2 Box Square 120 Required Installation Items 4 Wire Guide Components 1 Brackets Bracket Spacers x2 Adjustable Stop x2 3 Complete Blind FACE FIX INSTALLATION FLOOR FIX INSTALLATION I 1 l I I l 1 I l 1 i SWAGE ADJUSTABLE WALL MOUNTING BRACKET SWAGE ADJUSTABLE TURNBUCKLE SET ROUND EYE TERMINAL 4 2m X2 i TERMINAL 4 2m X2 PLATE i i WIRE i i WIRE X2 l X2 l l X2 l 1 1 I I l I I l I 1 I l I I l 1 I l 1 l J l OR l p 4 gt l 1 I l 1 l l l _ I 1 l I an I I I l l wm I
Download Pdf Manuals
Related Search
Related Contents
Irox METE-ON 8 Copyright © All rights reserved.
Failed to retrieve file