Home
JL269 Portable Gas Detector User's Manual
Contents
1. JL269 Portable Gas Detector JL269 Portable Gas Detector User s Manual 1 Description JL269 gas detector for industrial use has a high performance and wide detecting range It can be used to detect methane natural gases propane LPG Hydrogen and other combustible gases and can help you to find the gas leaking sources easily 2 Features Sensor doesn t need to be calibrated Quick response to combustible gas leakage Additional Long and flexible gooseneck tube Adjustable sensitivity 30 Level light Tricolor show Low battery alarming indication The sensor fault self detection GAS DETECTOR PRR RRR ERE eel e High concentration protect 3 Specifications Detecting Gas Natural gas LPG Sensitivity Better than 50ppm Detection range Alarm LED 1 Green LED 2 Yellow LED 3 Red LED ppm Scale No Environment Temperature 40 C 70 C Humidity lt 95 RH non condensing Warm up time lt 20S Response time lt 10S Indication 30 levels of LED indication Green low concentration Yellow middle concentration JL269 Portable Gas Detector Red high concentration Alarming levels The shorter the buzzer sound interval the higher the concentration Battery 3 6 1600mAh Ni H chargeable battery Charge time 4h to 6h Using time of the battery gt 8h Weight 310g Dimensions 1 70mmx62mmx26mm 4 Structure and Functions 12 JL269 Portable Gas Detector 2 Flexible gooseneck 8 scale Up 3 Concentrati
2. on LED scale down 4 Power LED Jack of charger Jack of earphone no Sensor fault LED 11 earphone included e FulscaelED 2 Batey OE e eee 5 Operation instruction 5 1 Turn on the detector Press and hold LD for about 1 second Power LED lights and the device begins to self test the 10 LED will light in turns Warm up time is 20 seconds When warm up finish the green power LED lights and all the alarm LED off the detector enter detecting status 5 2 Detecting Put the sensor into the gas environment and the LED and sound frequency will show the gas concentration of the environment With concentration increases first the green LED lights and the buzzer frequency increases When the concentration exceeds the first 10 levels detection range the alarming LED turns yellow and then turns red At the same time the sound frequency interval will turn higher When all LED turn red it means the concentration reaches the highest of the detection range At this point the C4 OL LED will light 5 3 Fault If there is something wrong with the gas sensor the detector can t work At this point the LA FAULT lights and all concentration LED off At the same time the buzzer gives sound of Didi Didi 5 4 Keyboard operation 5 4 1 Silence When alarming press both Lb and t the audible alarm is off When press them again the audible alarm is on 5 4 2 Zero adjustment If the de
3. or can continue to work for about 30 minutes When the voltage is seriously low the power LED begins to flicker about 2 seconds and then the detector turns off At this point you d better not turn on the detector frequently Otherwise the detector will be destroyed Besides if the detector can t be turned on or abnormal after turning on normally it is due to serious low voltage Please charge it at time 6 2 Charge We kindly suggest you charge the battery when the detector is off because if on the battery will not be charged full When charging put the plug of the charger into the AC220V or AC110V power socket Then the LED of the charger turns red The charging begins Fast charging time is about 3 to 4 hours when it s full the LED turns green and then you can use it normally We suggest you charge it for 4 to 6 hours Note Please don t charge the battery at the detecting spot so as to avoid fire or explosion due to the spark when pulling out the plug Please don t charge it when the detector is on so as to ensure the charging speed When charging frequent turning on and turning off are not allowed otherwise the detector will be destroyed 7 Troubleshooting Guide Turning off immediately after turning Seriously low voltage Charge it promptly on Warm up doesn t end Wait till warm up ends No response to the gas Sensor fault Replace the sensor 8 Fittings Detector 1pc Charger 1pc Manual 1pc
4. tector indicates small concentration and you want the present level as zero point press both LiF and a then the detector accept the present level as zero 5 5 3 Scale up When all the red LED light it shows the present gas concentration is above the presetting scale then press Li continuously continuing press operation acceptable to choose larger scale when you press and release ir the green alarm LED will light showing the present scale number the quantity of the green LED indicates the corresponding scale see table 1 for the details JL269 Portable Gas Detector Note larger scale less sensitivity So the larger scale is not suitable to low gas concentration 5 5 4 Scale down When the gas concentration around is not very high you can choose lower scale to detect Then you can press Eh continuously continuing press operation acceptable to choose smaller scale Note smaller scale higher sensitivity 5 5 5 Turn off When the detector is on press both and oh the detector turns off 6 Battery and charging This detector adopts 3 6 1600mAh chargeable battery as power It can work for more than 8 hours continuously 6 1 Battery voltage indication When the detector is on you can test the voltage of the battery When the voltage is low the CA POWER LED turns red which means low voltage and it needs charging In the status of low voltage the detect
Download Pdf Manuals
Related Search
Related Contents
Auricular Bluetooth Nokia BH-217 Philips Entertainment Tablet PI3000O2 SINVERT M3062PT-EPBM User`s Manual ( for replacement ) SERVICE MANUAL - e-ASP 10月9日(水) 開催(東京) - NPOセフティマネジメント協会 Samsung LW22A13W User Manual Copyright © All rights reserved.
Failed to retrieve file