HUNTER-PRO 32 Intruder Alarm System User Manual
Contents
1. J Z i gt gt _ par NJ 0 AJ D lt gt Ua m NJ i gt _ NIL ZRA Appears following a prolonged power failure during which the backup battery was completely discharged Set time Perform system self test see section 3 6 Verify during the test that other instruments connected to the Alarm System s telephone line i e telephone sets facsimiles etc are not active If the fault persists call the installer Tamper 1 Tamper switch 1 is open Call the installer Tamper 2 Tamper switch 2 is open Call the installer Low pwr Appears before the back up battery is completely discharged usually after a prolonged power failure Follow instruction for low battery failure EEPROM Parameter programming fault Call the installer Zone Trb OM M One of the protected zones is faulty Call the installer Software failure Call the installer es Ie System failure Call the installer Failure to communicate with Monitoring Station Call the installer Commun Det Vitg Detector power supply Call the installer No communication between the keypad and the HUNTER PRO motherboard Call the installer Keypad not connected Other display use APPENDIX user notes Programming is done from another keypad or system is controlled via telephone
2. FOR BETTER PROTECTION HUNTER PRO 32 Intruder Alarm System TM PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel 972 3 5587722 972 3 5500442 A support pima alarms com gay http www pima alarms com A HUNTER PRO 32 Intruder Alarm System Installation Manual PIMA Electronic Systems Ltd does not represent that its Product may not be compromised and or circumvented or that the Product will prevent any death personal and or bodily injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The User understands that a properly installed and maintained equipment may only reduce the risk of events such as burglary robbery and fire without warning but it is not insurance or a guarantee that such will not occur or that there will be no death personal damage and or damage to property as a result PIMA Electronic Systems Ltd shall have no liability for any death personal and or bodily injury and or damage to property or other loss whether direct indirect incidental consequential or otherwise based on a claim that the Product failed to function Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For various reasons including but not limited to changes in environment cond
3. that after which the system commence auto arming Silence Time in minutes Press to save programming and move to the next screen 3 5 Disarming the System 3 5 1 Disarming the System with Master Code ON OFF sa 3 5 2 Disarming the System with User Code User Code Entering the code will immediately disarm the system OR E Enabled User Code lran a Y ON OFF sa OR HUNTER PRO 32 Intruder Alarm System Installation Manual If the system does not turn to Disarm state make sure that the time is included in the preset time frame that enables disarming the system see section Programming User Codes 3 6 Remote Control via Touch tone Phone The alarm system can be remote controlled via any touch tone telephone including cellular phone The system can be controlled from the moment there is communication between the system and the telephone whether the system called the telephone or when initiated by the user as following described 1 Dial the telephone number the system is connected to 2 Wait for the system s confirmation tone a long tone followed with two beeps 3 Enter Master Code note NOT to enter the code before the end of the confirmation tone 4 Wait a few seconds until the alarm system confirms its status using one of the two following tones Continuous tone System disarmed beep System armed The system will not identify commands from the te
4. NOTE REM 3 is only available for HUNTER PRO with wireless add on system The remote is a Code Hopping type i e the code is changed with each operation and thus prevents code stealing with a key holder for carrying with ones keys HUNTER PRO 32 Intruder Alarm System Installation Manual To arm the alarm system press the GREEN button on the remote control DISARM To disarm the alarm system press the RED button on the remote control TOME MODE To arm the alarm system in a Home Mode press the BLUE button F z PANIC A To send a panic signal to the alarm system press the BLUE and GREEN buttons together for 3 seconds It is possible for the technician to program the system to produce a short beep when the system is armed with the remote control Doing so the user can also get indication if the remote control s battery is low 3 3 Arming Disarming with Key HUNTER PRO 32 can be armed disarmed with a key Turn to the technician in order to install this feature NOTE Sy It is possible for the technician to program the system to produce a short and beep when the system is armed with the key 3 4 Automatic Arming The system can be automatically armed with one of the following two options 1 At a preset time 2 After no detection period At the preset time or after no detection period the system will commence auto arming unless it was armed before that time This feature is
5. valid for all weekdays as HUNTER PRO 32 Intruder Alarm System Installation Manual The system can detect movement in the protected area via its connected detectors and sensors therefore it can identify no movement hence there is no one in the protected area When the system starts auto arming the display will show Automatic Arming and a 45 seconds warning countdown will start indicating the arming countdown is to follow Note that during the warning countdown the keypad will beep During the warning countdown any disarming code can cancel the auto arming process After the warning countdown is over the system will begin regular arming process including exit delay and a beep from the keypad 3 4 1 Programming Auto Arming at Preset time Master Code Enabled User Code insose 1s 2 OR PROG PLOY Geer cong The following screen will appear Press and move to the next screen Enter E ime in which the system will be armed NOTE Sy To cancel Auto Arming the Automatic Arming programming needs to be repeated and the time to be set as 00 00 Press to save programming and move to the next screen HUNTER PRO 32 Intruder Alarm System Installation Manual s 3 4 2 Programming Auto Arming after no detection period E Master Code Enabled User Code ee OR PROG PLO Gray sge In the following screen enter the no detection period in minutes
6. Arming the system to mode Home _ Fast arming the system to 1 partial arming Home 1 mode if enabled by i technician Display menu see section Zone _ _ Status Display Programming ne numbers rN Arming Uani system to mode Home 2 Fast arming o system to partial arming Home 2 mode if enabled by a rs Programming time and date Ca gt Programming the user codes oaan zones for Chime feature Enabling Disabling the Chime feature Programming automatic arming pe Programming key Smoke detector reset HUNTER PRO 32 Intruder Alarm System Installation Manual p key Display service Provider information Programming key Test siren battery AC and tel aie key Display system s name and version 2 3 Entering User Menu In order to program and change data in the user level you must first enter the User Menu User Menu can be fully accessed by the system administrator owner when using the Master Code Other users can also access the User Menu but are limited to the number of available functions according to their authorization level programmed by the system administrator owner To learn more about authorization levels and how to change them see Programming Codes on page 22 2 3 1 Entering User Menu with Master Code To access the User Menu S Master Code 10 er Function key see page 2 3 2 Entering User Menu with User Code If us
7. E The battery s status can be tested only when the system is connected to mains power source er Master Code Enabled User Code Zero long press User Code HUNTER PRO 32 Intruder Alarm System Installation Manual Follow the test process displayed on the screen in case fault messages appear 4 9 Canceling Keypad Buzzer The keypad produces a variety of sounds at times of pressing a key confirming a long press during countdown disarming the system and so on Simultaneously pressing the keys activates cancels this feature NO Nee When the buzzer is cancelled no sounds will be produced from the keypad 4 10 Bypassing Zones This feature is used for temporary bypassing of zone s for example in case of a fault S Master Code Enabled User Code Zero long press User Code s eS to confirm or jw In PIMA Display the letter B will appear above below the bypassed zone s and display will continue to the next screen 4a number of times unit exiting to time zone screen 4 11 Memory Log The system memorizes up to past 410 events and operations in a chronological order HUNTER PRO 32 Intruder Alarm System Installation Manual 4 11 1 Accessing Memory Log Manually S7 Master Code Enabled User Code Zero long press User Code S S 2 VE scrol events using and Back Press Ez to jump 10 events in one key press 4 11 2 Memory Log Display Arming and disarming are memorized with the nam
8. Manual To cancel arming i system returns to normal operation mode 3 1 2 Arming with Master Code S Master Code e E E NOTE The The system s default Master Codeis 5555 sid s default Master Code is 5555 3 1 3 Fast arming with User Code and or Short Code Pressing the code shall arm the system immediately Se Short Code er 3 1 4 Arming the System to HOME state Arming to HOME 1 PJ CE hort Code or User Code or Master Short Code or User Code or Master Code or User Code or Maste Arming to HOME 2 JEA S Short Code or User Code or Maste After long pressing the HOME key i e ao entering ems ST E code the Slaw message is displayed Lor MUM according to the pressed key 3 1 5 Fast Arming o quickly arm the system if enabled by technician ON OFF x Ful Arming P 16 HUNTER PRO 32 Intruder Alarm System Installation Manual HOME 1 Arming HOME 1 p Arming HOME 2 p NOTE Sy Exit delays in HOME 1 and HOME 2 can be disabled by technician 3 1 6 Arming via the User Menu ON OFF If user is enabled by technician to enter the User Manu If user is not enabled by technician to enter the User Menu it can still be accessed as follows Lo ON OFF 3 2 Arming Disarming with Remote Control Optional feature REM 3 remote control has three buttons arming disarming and HOME 1 Turn to the technician in order to install this feature
9. UNTER PRO 32 Intruder Alarm System Installation Manual 2 1 2 PIMA Display All events and zones displayed in a single screen using signs and abbreviations System 22 23 24 25 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 bo me Zone Status and Events Upper Line Display Time and date if system has 16 or les zones If more upper line displays data like the lower line Lower Line Display The following signs appear above or below when in upper line the zone number partitions that encircle the LCD screen Closed zone H Opened zone Bypassed zone inf Alarm zone zone triggering alarm amp Chime zone Shortcut zone zone was shortcut Failed zone disconnected Tamper event in a wireless detector Low battery in wireless detector Supervision signal Wireless detector did nor report test to system 10 HUNTER PRO 32 Intruder Alarm System Installation Manual If technician selected PIMA display the system will not display the zone status during faults Only after faults resolved PIMA Display renews Operating and programming the system commences by first entering the Master Code and then pressing any further required keys However a number of keys enable certain actions by a single long press without the Master Code short press long press Capertee abea by eneen enabled by technician ER a arming alarm and fault J histories lt 2 Temporary bypass of zones
10. e if the code that initiated them along with any bypassed zones present at the time The list of the bypassed zones is presented before those of the arming Automatic armings are also memorized Example 1 Event number Date Hour 17 18 19 20 27 28 29 30 21 22 23 24 25 26 Lone Levent Note that at a time of an alarm in addition to the screen above automatically appears another screen with the zone s name e g in this example the following screen will show Front Door Example 2 Example 3 a HUNTER PRO 32 Intruder Alarm System Installation Manual 4 12 System Display Types HUNTER PRO 32 has two possible system displays PIMA Display All the zones and their status appear in a single screen Scrolling Display A detailed description of the zones and their status each zone in a different screen and automatically appearing one after the other In order to choose display type e Master Code Enabled User Code Zero long press User Code es Je En display changes from PIMA Display to Scrolling Display and vise versa 4 12 1 Zone Status Display HUNTER PRO 32 Intruder Alarm System Installation Manual IMPORTANT aall Pressing gt in Zone List Opened Zones Bypassed Zones Soak Test Zones Chime Zones screens gives a detailed description of the zones in this category NTR Pressing in Activated Partitions screen gives the detailed d
11. eeeeneees 40 a HUNTER PRO 32 Intruder Alarm System Installation Manual CHAPTER 1 INTRODUCTION Congratulations on your purchase of the HUNTER PRO 32 Intruder Alarm System Much care has been taken in developing the HUNTER PRO Intruder alarm system which will provide you with unprecedented peace of mind The HUNTER PRO user friendly operation and advanced features will professionally protect your home or business HUNTER PRO 32 Intruder Alarm System contains numerous features that allow it to befit the customer s individual needs and yet remain easy to program and use both by the customer and the technician Therefore it is important to read this manual from cover to cover in order to familiarize yourself with the system and take full advantage of its features To assure optimal safety and security you should test the HUNTER PRO 32 Intruder Alarm System once a week For any further questions please do not hesitate to contact your local PIMA distributor or PIMA directly at PIMA Electronic Systems Ltd Tel 972 3 558 7722 Fax 972 3 550 0442 Email support pima alarms com Up to date literature is available to download from our website www pima alarms com HUNTER PRO 32 Intruder Alarm System Installation Manual 1 1 Main Features HUNTER PRO 32 8 to 32 zones with wireless add on local and remote bus expanders Supports a wide range of partition options n Up to 16 partitions each with it own Account ID and Use
12. er is enabled by technician to enter the User Manu er Prowse Let S Function key see page 10 If user is not enabled by technician to enter the User Menu i e User Code arms disarms the system the menu can still be accessed as follows HUNTER PRO 32 Intruder Alarm System Installation Manual PLO F Geer cody P naon key ee page 10 When user selects a function i e the corresponding key is pressed that he or she does not authorized to the system displays the following see HUNTER PRO 32 Intruder Alarm System Installation Manual CHAPTER 3 ARMING amp DISARMING THE SYSTEM The system can be armed and disarmed using one of four methods Keypad Remote control or key Automatically arming only Remotely via telephone As a rule the system should be armed ONLY when all zones but those on the exit route are closed and there are no faults e g battery mains etc and or events e g fire panic etc It is possible to arm the system with open zones but these zones should be bypassed for the system to be armed see Arming with Open Zones on page 14 IMPORTANT When a zone is bypassed it will NOT produce an alarm in case an intruder will be detected at that zone The technician should enable the option to auto bypass open zones when the system is armed remotely remote control key or via the phone or when the system is auto armed If not enabled the system will n
13. escription on the zones in this category in the following manner Partitions marked by an X Activated Partitions marked by an Not Activated In order to scroll between zones in the same category use the SERVICE HUNTER PRO 32 Intruder Alarm System Installation Manual CHAPTER 5 TROUBLESHOOTIN G lf more then one failure is detected the display will scroll the failure list one after the other If more than one keypad is connected to the HUNTER PRO and you are programming the system from one belay tem Mie mee on all other keypad will display ALF Hi FA Ss if US amp This will also be displayed whenever the keelen uses a acen in order to program the HUNTER PRO or when someone is in control of the HUNTER PRO via telephone The following table describes the possible Alarm System Faults Displayed What can I do Fault Battery Wait approximately 24 hours for the indication to disappear If the fault indication persists longer then one day the back up battery should be replaced Wireless A wireless receiver failure can be the cause of Receiver communication failure between the detector and receiver AC voltage Usually appears during a power failure If other electrical appliances in the house are operating check the switch or fuse to which the alarm system is connected If the cause of the fault is unclear call the installer HUNTER PRO 32 Intruder Alarm System Installation Manual
14. fter a oa HUNTER PRO 32 Intruder Alarm System Installation Manual minute of not receiving any command see Remote Control via Touch tone Phone on page 20 In case a Voice Unit is connected to the system once the call is picked up there is a recorded message and nota warning sound The dialer aborts the dialing attempts in the following cases The system s status changes from ON to OFF A Stop Siren Dialer command was received via telephone The first Private Dialer User that gives an abort command causes the other Private Dialer Users in the phone list will not receive the system s report All Private Dialer Telephone Numbers were dialed to twice 4 3 1 Programming Telephones It is possible to combine the process of Entering Deleting Changing programmed telephone numbers once in the Telephone Menu 4 3 1 1 Programming User s Authorizations Master Code Enabled User Code Zero long press User Code S 8 Enter telephone number 7 E Ener 2 telephone numbed OIF Ener 2 telephone umeog P E e Erter 3 telephone number 7 I Eter 3 elephone number 4 1 1 1 Deleting a Programmed Telephone Number To delete a programmed telephone number press the key instead of the telephone number HUNTER PRO 32 Intruder Alarm System Installation Manual 4 4 Chime Programming the Chime feature enables to control opening closing doors and windows by activating the keypad s buzze
15. he display will repeat itself for a few minutes until it will return to the regular screen of an activated system In addition the system will commence other actions according to the zones programmed features at time of alarm such as dialing private telephone numbers disabling siren silent alarm dialing monitoring station and more Example 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 S gt NOTE The zone names are programmed only by the technician HUNTER PRO 32 Intruder Alarm System Installation Manual RESET CHIME To activate panic press and hold simultaneously the _ keys for two seconds You can customize your system s response to a panic event for example calling the Monitoring Station or your private telephone number activate a relay video camera activate siren etc Consult your installer about programming the appropriate Panic Response for your needs 4 6 1 Panic Button Pa Optional feature Pressing the button triggers X sirens and send a panic signal to monitoring station and or dial to private telephone number according a amp Z to technician programming 4 7 Smoke and Fire Detectors Alarm In case an alarm is triggered due to smoke fire detectors press and hold the _ key until a confirmation sound in order to reset and release the detector 4 8 System Tests This feature tests that the back up battery siren and telephone line are in order NOT
16. icnsereunceaea 7 2 1 Display Screen sesesessssssssosasanusunununnsnsnnnenenensnsnnenenenenenuns 8 22 ARGVS F O aaa N 10 2 3 Enternng User MenU sersissenasirs ii 11 CHAPTER 3 ARMING amp DISARMING THE SYSTEM 13 3 1 Arming Disarming via Keypad ccecceceeeeeeeeeeeeeeeeeaeeaees 14 3 2 Arming Disarming with Remote Control ccsccseseeeeeeeeeees 16 3 3 Arming Disarming with Key cccceccsecseeeseeeeeeeeeseeeeeeees 17 34 AULOMAUC AMINO ssmimi 17 3 5 Disarming the System ssssssssssssusnsnnnsnnnenenensnnanenanenenene 19 3 6 Remote Control via Touch tone Phone ssssssssssssrsrsrernserenes 20 CHAPTER 4 PROGRAMMING AND OPERATION scscseseaees 22 4 1 Programming Codes cccccsceeeeneecensenecnseeenecnecnenecnenensens 22 4 2 Programming Time and Date cccccceccseeeeeeeeeeeeaeeeeneees 31 4 3 Private Dialer Telephone Numbers cccscceeeeeeeeeeeeeeeees 31 or CO aanncesascemeenasaetwecsunesaepeiesrssqnaesd aaaseeesaneinereucanesensers 33 FD Aea E annie 34 Avo PANIC n 35 4 7 Smoke and Fire Detectors Alarm ccccccseseceeeeeeeeaeeeeeneaes 35 TO SVSlEMl T S glace etd comeonaaveatanpros 35 4 9 Canceling Keypad BUZZer csccsccsceeeseeeeeeeaneneeeeeseneneens 36 4 00 Bypassing ZONES suisses e 36 TE Memory LOG eer 36 4 12 System Display Types ccccsecsecseeeseeseeceeeneneeeeensansneens 38 CHAPTER 5 TROUBLESHOOTING ccccceeeeeeeeeeeeeeeeeeeeeeee
17. itions electric or electronic disruptions and tampering the Product may not perform as expected The user is advised to take all necessary precautions for his her safety and the protection of his her property This document may not be duplicated circulated altered modified translated reduced to any form or otherwise changed unless PIMA s prior written consent is granted All efforts have been made to ensure that the content of this manual is accurate Pima retains the right to modify this manual or any part thereof from time to time without serving any prior notice of such modification Please read this manual in its entirety before attempting to program or operate your system Should you misunderstand any part of this manual please contact the supplier or installer of this system Copyright 2004 by PIMA Electronic Systems Ltd All rights reserved You can contact us at PIMA Electronic Systems Ltd 5 Hatzoref St Holon 58856 Israel http www pima alarms com HUNTER PRO 32 Intruder Alarm System Installation Manual B TABLE OF CONTENTS CHAPTER 1 INTRODUCTION sssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 4 1 1 Main Features HUNTER PRO 32 ssssasssssnnnnsnnnnnnnnnnnnnnsnnnnsnnnn 5 1 2 Safety Precautions s sssssessssnsasasnsnnnnnnnnnenenensnsnnanenenenunune 5 1 3 Signs and Abbreviations Key s sssssesenensnsnsnsnsnsnnnnnnnenennnns 6 CHAPTER 2 KEYPADS vecrsraescacavaeteniavnncececeswancsseseseans
18. lephone while sounding the confirmation tone It is important to wait until to confirmation tone is over before pressing the telephone keys that control the system 5 Execute command by pressing a key on the phone The following table includes system s commands by phone keys HUNTER PRO 32 Intruder Alarm System Installation Manual Phone key Function Arm the system Disarm the system Arm the system in Home 1 mode Switch on the Relay Switch off the Relay Arm the system in Home 2 mode Listen in only available with a MIC 100 Disables siren and dialer in case of an alarm COON AD UI BRN NOTE The alarm system confirms the command was received by two short beeps While the system and the telephone are communicating the following message will display on all connected keypads If the system does not receive any command for a period of 60 seconds it shall disconnect and return regular operation mode The system will remain in standby with the above displayed on keypads for another 60 seconds before keypad operation returns HUNTER PRO 32 Intruder Alarm System Installation Manual CHAPTER 4 PROGRAMMIN G AND OPERATION 4 1 Programming Codes A code is a combination of numbers that allows programming arming disarming the system and more During the programming process the keypad s display will show the name of the code you want to program At any stage of the programming it is pos
19. o arm the system CODE OR PROG CODE 2 irca The following screen will appear when using Master Code when using Enabled User Code PUE Enter new code 2 digits E to save END Press a number of times unit exiting to time zone screen HUNTER PRO 32 Intruder Alarm System Installation Manual 4 1 4 Programming Duress Code This code is useful when the system is connected to a security station The Duress code will disarm the system if armed and trigger the Silent Alarm sending a duress signal to the security Station without activating the sirens Note the code is between 4 to 6 digits e Master Code Enabled User Code a OR PLO mg The following screen will appear when using Master Code when using Enabled User Code Salou We er Eur e CEP ENTRY P save Press a number of times unit exiting to time zone screen 4 1 5 Programming Door Code Arms and disarms a system s relay Useful for opening and closing electric gates activating video cameras and more The code can be HUNTER PRO 32 Intruder Alarm System Installation Manual used manually directly pressed on keypad and remotely via telephone see section 3 6 Remote Controlling via Telephone Each entering of a Relay Code changes the relay s status ON to OFF and vise versa When the relay is ON the letter R appears on the display left to the time The rela
20. ot arm with open zones IMPORTANT When automatic bypass is enabled you will have NO indication when arming the system remotely a HUNTER PRO 32 Intruder Alarm System Installation Manual 3 1 Arming Disarming via Keypad 3 1 1 System Messages During Arming 3 1 1 1 Arming with Closed Zones normal arming Before arming the system make sure all zones except exit delayed zones uSually zones on exit route are closed make sure that in the keypad display above below all the LCD zones numbers there is not a i sign blinking or an opened zone indication The system can be activated using one of the following codes Master Code User Code and Short Code After entering one of these codes the green control LED shall begins to blink a beep will be heard from the keypad and the display will show the exit delay message At the end of the exit delay the green control LED shall stop to blink and stay on the A will stop cla the display will show the following message mestem tet and then change to the following display ante 3 1 1 2 Arming with Open Zone s When activating the system with one or more opened zones that are not on the exit route i e exit delayed zones the keypad will produce a fast beep and the display will show Scrolling line Open Zones amp Events To bypass open zones 2 open zones are bypassed amp system armed HUNTER PRO 32 Intruder Alarm System Installation
21. ot expose this alarm system to rain or moisture Do not open the door of the alarm system Dangerous high voltages are present inside of the enclosure Refer servicing to qualified personnel only This alarm system should be used with AC 230V 50Hz To prevent electric shocks and fire hazards do NOT use any other power source Do not spill liquid of any kind onto the unit If liquid is accidentally spilled onto the unit immediately consult a qualified service Install this product in a protected location where no one can trip over any line or power cored Protect cords from damage or abrasion Disconnect all sources of power supply before proceeding with the installation Connect the AC wires to the terminal block on the PCB as marking Pay attention to polarity 1 3 Signs and Abbreviations Key Regular key press Long key press until confirmation beep is heard ao Press this key at any programming stage in order to return to root screen Default Master Code 5555 Enabled User Code A code enabled by Master Code to enter User Menus LCD Zone Numbers Referring to the frame of zones engraved above and below the LCD display window indicating the zones numbers HUNTER PRO 32 Intruder Alarm System Installation Manual Gi CHAPTER 2 KEYPADS HUNTER PRO 32 works with PIMA s LCD keypads RXN 400 and RXN 410 especially designed for maximum simplicity durability and decorative design The ke
22. r for two seconds each time a door window is opened This feature is especially useful when there are small children in the house or in shops S gt NOTE The Chime feature is only enables when system is disarmed 4 4 1 Programming Chime Zone a Master Code Enabled User Code Zero long press User Code cer Ene to confirm or _ to release Wr On the display the letter L shall appear above below the zone programmed to trigger the chime and the screen will move to the next zone 4a number of times unit exiting to time zone screen 4 4 2 Temporary Cancellation of Chime Temporary cancellation of chime is valid for all zones PRJ Press and hold the EZ key to enable disable the chime feature according to the state in which the system is in the display will show one of the following messages wR HOLLU Pare Lisi bes HUNTER PRO 32 Intruder Alarm System Installation Manual 4 5 Alarm There are two possibilities for displaying the name and number of the zone s that triggers the alarm at the time of an alarm The technician sets the default display PIMA Display All the zones and their status appear simultaneously in a single screen see section 2 2 PIMA Display Example 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Scrolling Display The name and number of the zone s that triggered the alarm will appear separately each in a different screen in an automatic successive manner T
23. rs Up to 8 subsystems each with different keypads IDs etc Full supervision data of wireless detectors life signal low battery fault Comprehensive Zone Tests for flawless installation Walk Test Soak Test etc Two options for viewing system status n PIMA Style Status of all 32 zones is displayed simultaneously Detailed Scrolling events zones and system s status Four Subscriber dialing numbers with optional voice message Four Monitoring Stations phone numbers PIMA unique Integrated Digital Communicator telephone long range radio Supports split and double reporting with different account IDs LCD keypad with multilingual Menu Driven screens for easy programming and operation Many alternatives for easy programming Keypad Fast Programmer Local Remote download software Up to 28 user codes with various authorization levels Easy and user friendly operation with single key operation Various accessories microphone voice unit etc Memory Log up to 410 events 100 are non volatile Automatic Arming at a preset time and or after a preset silence time System remote control via any touchtone telephone Your Hunter alarm system has been registered with the CE in accordance with EN 60950 of its rules The CE requires us to tell you the following information HUNTER PRO 32 Intruder Alarm System Installation Manual To reduce the risk of fire or electric shock do n
24. s default K User can operate partition via any keypad when using partitions User can operate partition ONLY via designated keypad default A User can program auto arming parameter User cannot program auto arming default 4 1 2 5 Programming User s Disarming Window gr Ee y This feature sets the time frame start and end time in which the user can disarm the system By default the user time is not limited i e start 00 00 end 23 59 4 1 2 6 Programming User Partitions cor Ents Spex X5 This feature links a user to a partition s When creating subsystems there is also a keypad linked to each split done by the technician therefore the user can only arm disarm and view the linked partition using the designated keypad When a user is required to control partitions using any keypad the option K on the authorization bar should be set to With standard system installation i e no partitions all users are assigned by default to all partitions HUNTER PRO 32 Intruder Alarm System Installation Manual To scroll on User Partitions Bar use Marking a above a partition allocates it to the user Marking a denies this possibility N OW In order to change the mark from to and vise versa press the _ key There is no limitation in the number of partitions allocated to a user 4 1 3 Programming Short Code This two digit code is only used t
25. sible to IMPORTANT Pay attention that HUNTER PRO 32 has a code control feature that does not allow entering identical codes For example if one of the user or master codes is programmed as 1010 any attempt to program a new code as 1010 or starting with 1111 e g 10101 10102 10103 etc will display an error message 4 1 1 Programming Master Code The default Master Code is 5555 The Master Code can ONLY be changed with the master code The Master Code is used for accessing memory and programming different function as described further It is also possible to arm and disarm the system with the Master Code IMPORTANT Pay attention that the code need to be between 4 and 6 digits HUNTER PRO 32 Intruder Alarm System Installation Manual IMPORTANT For better protection change the default code after installation 4 1 2 Programming Users The User Codes are mainly for arming and disarming but depending on the user s authorization level the user can also go into the User Menu and perform various tasks as viewing memory changing other users settings program telephone numbers etc HUNTER PRO 32 holds up to 24 different User Codes 4 to 6 digits each See Entering User Menu on page 11 for a description on how to access the User Menu with User Code A name can be programmed for each user a time frame in which he will be active allocation to one partition or more as well as limiting authori
26. udes up to 8 characters letters or digits Each arming disarming will enter the memory along with the user name date and time see section Memory Display on page 36 The order of the ABC letters is identical to that in a cellular phone 1 ABC2 DEF3 Cancel ON OFF MEMO BYPASS ER RES BED GHI4 JKL5 MNO6E Nextchar HOME 1 ZONE PHONE SERVICE 4 Us 8 PQRS7 TUVS8 WXYZ9 Prev char HOME 2 CLOCK CODE Z 2 0 Save HUNTER PRO 32 Intruder Alarm System Installation Manual The following example illustrates key depressions for the word 7PIR 4 1 2 4 Modifying User Access Br ENTR o gt next X3 code programming bar To scroll on Access Bar use and keys Marking a under a parameter s letter authorizes the user to program this parameter Marking a denies this possibility In order to change the mark from to and vise versa press To save data press User Access Bar parameter letters U User can program User Codes default User Code programming is disabled T User can program phone numbers default Phone numbers programming is disabled C User can program time and date default Time and date programming is disabled HUNTER PRO 32 Intruder Alarm System Installation Manual EA M User can view the Memory Log User cannot view Memory Log default B User can bypass zones User cannot bypass zone
27. y is activated for a preset time programmed by the technician The Code is between 4 to 6 digits e Master Code Enabled User Code aa OR PROG PLOY Geer cong The following screen will appear 2 when using Master Code when using Enabled User Code to save new relay code Press ee a number of times unit exiting to time zone screen HUNTER PRO 32 Intruder Alarm System Installation Manual 4 2 Programming Time and Date Time and date are constantly displayed on screen used for the User Code s time frames and are included in the system s memory log It is crucial that the time and date remain accurate especially for the memory log which is crucial for the technician visits E Master Code Enabled User Code ee OR PROG Date Enter time in 24 00 HH MM format and date in day month year format The system will not accept meaningless data such as 25 25 time In such a case a fault message will appear To correct press the key and enter time again 4 3 Private Dialer Telephone Numbers HUNTER PRO 32 system has four private dialer telephone numbers The dialer will dial each phone number in two sets i e total of 8 attempts and trigger an alarm warning sound when the call is picked After the warning sound is over the system awaits for remote controlled commands that can be transmitted via the telephone used by the system The system shall hang up a
28. ypad is used for arming disarming and programming the system as well as displaying time and date system status information events and defaults memory log and more Both keypad models are identical except for the size of the display screen RXN 410 Large screen 23 x 97 mm RXN 400 Small screen 15 x 60 mm Up to eight keypads can be connected to the system System display System display Date amp Time PE ETA eee D eee ae oe Zones Status Hi aea aana y eaa ITT T a R sa tn ee eed a F aaea O y TTT Num amp Function ARM LED green keys Fault LED Navigation amp red Programming keys a HUNTER PRO 32 Intruder Alarm System Installation Manual 2 1 Display Screen The display screen has two lines with 16 characters each The upper line displays the time and the date The lower line displays data regarding the system such as events faults and zone status The user can choose between two display types scrolling fast zone display and PIMA display 2 1 1 Scrolling The zone and event screens automatically interchange and display their status in a chronological order oe Stems Upper Line Display Time and date System status displayed between time and date System communicating or testing PSTN line Siren ON Relay ON System reporting to Monitoring Station via radio transmitter Lower Line Display Events and faults Opened zones ii H
29. zations User Code is a number of 4 to 6 digits S Master Code Enabled User Code Jl eaae i a OR PROG PLO lerc The following screen will appear Master Code HUNTER PRO 32 Intruder Alarm System Installation Manual Enter user number 1 24 Enabled User Code F 24 NOTE SF An asterisk placed to the right of the user s name means that the user is already defined in the system Following are the different options with user programming 4 1 2 1 Changing adding new User Code Enter a new User Code 4 to 6 digits and press to save 4 1 2 2 Deleting User 4 1 2 3 Entering User Name a Ena You are now ready to enter text HUNTER PRO 32 Intruder Alarm System Installation Manual How to Select and Enter Characters Each numeric code entry key has characters associated with it the same as with standard cell phone letters The number of key depressions you make determines which character is selected e g the numeric key represents MNO6 To select M press the key once to select O press the key three times See bellow for all keys and their associated characters Pressing the NEXT key moves the cursor forward one character Pressing the key moves the cursor backwards one character Pressing the key saves the data Pressing the EZ key deletes a character number letter as well as a whole user name User Name incl