1. MLPHN Tech G S M G AT E Installation guide V 1 0 Basic features Mini Gate A is dual band GSM Gate based on Siemens GSM module TC 35 eventually MC 55 eguipped by a lot of adjustable features increased comfort of service It has been designed for GSM network 900 MHz as same as 1800 MHz e Polarity reversal of telephone line allows exact detection of start and end of call e CLIP support all ordinary protocols and allows send not only incoming call number but also name when is saved in phonebook e Call billing allows control exact call duration due tax pulses 12 16 kHz 1 pulse when outgoing call is picked up e Beeps in minute period into the call allows easy identification of GSM call e Integrated USB port with PC software allows you easy configuration as same as sending and receiving SMS messages via SMS mail sw or data transmission option Thanks of many Mini Gate features you can satisfy very wide group of customers By setting of permitted numbers to memory of Mini Gate you can restrict unreguested calls to public numbers As same as you can set Mini Gate to provides incoming calls only USB Mini USB cable telephone line 2 By pressing of yellow button release the SIM card holder Insert the SIM card and replace the SIM card holder Before inserting the SIM card we recommend checking at various mobile phone state of the SIM card logging with or without PIN PIN
2. etc and set logging without PIN When you want logging with PIN you have to preprogrammed this PIN and set logging with PIN via table of programming Without this setting the Gate wont work DO NOT FORGET ANTENNA CONNECTION The available place for installation select up following point of view 1 distance from PBX possibility of GSM interferences to other PBX lines as same as lenght of line from Gate to PBX max 200m 2 main 230 V for power supply of Gate 3 Ouality of GSM signal at the installation place of GSM Gate Ouality of GSM signal The sound guality depends on BTS setting where you are connected by the Gate To find best place for antenna mounting you can use either mobile phone or feature 29 table of programming The suitable signal power is 3 scales of mobile graduation To check and find best position from GSM signal point of view you can use also GG SET configuration sw More in manual for GG SET 3 Connection of antenna When you connect magnetic antenna keep on mounting at bigger iron subject This subject makes against weight at its depends the power of radiated signal When you inserted SIM card as same as all cables are connected do not forget that Blue gate is connected on external line not on extension connect device to main 230V The blue LED of power supply is light up within 10 sec After a while will flash a few times unregularly yellow LED GSM network registration Tle CPU
3. provider USB Mini Gate A various temperature 5 C 40 C humidity 10 80 at 30 C 230 V 10 adapter max 15 VA thermal fuse in adapter SN EN 60950 group 2 2 wires RJ 11 600 O 20 tone DTMF t gt 30 ms Pulse 28 200 20 200ms 12 16 kHz Polarity reversal symetrical 24V max 38 mA max 500 55 Ve 50 Hz 425 Hz 20Hz FSK Bell BT DTMF compatible for GSM 900 and GSM according SIM card 3V and 1 8 V version 1 1 virtual COM Functionality Waiting for dial after pick up 1 99 sec or unlimited Waiting for last digit of dial 1 15 sec Dial after preprogrammed number of digits 1 19 Immediate dial sent up setting or Permitted direction 9 memories of 4 digits numbers Dial type setting CLIR CLIP Call billing tax pulses 12 16 kHz Reversal polarity start and end of call Roaming ON OFF Call duration control Time beepsin call GSM signal strength identification Cz ALPHA Tech Alphatech spol s r o Jeremenkova 88 140 00 Praha 4 tel 272 103 335 fax 272 103 334 e mail alphatech alphatech cz internet http www alphatech cz na e sou adnice GPS WGS 84 N 50 02 35 5 E 14 25 42 0 8 11 2007
4. 0 tone and pulse dial is acceptable n gt pulse dial is acceptable only tone dial i is acceptable onl Ringing after inicialization nn decimal of sec 00 to 99 it is 9 9 sec 00 not ringing during inicialization Waiting nn sec for dial after pick up 00 to 99 it is 9 9 sec 00 waiting is not limited Number of dialled numeral after its is dial send immediatelly lenght of telephone number nn 00 function none active nn 01 19 number of numeral telephone number nn 00 99 decimal of seconds CLIR feature switching OFF outgoing CLIP 143 174 n 0 OFF ON Xx 00 No charging pulses Xx 12 12 kHz charging pulses Xx 16 16 kHz charging pulses Yy 00 1 pulse only at the moment of connection Yy 01 to 99 seconds Pulses each 01 up 99 seconds CLIP is switch OFF FSK CLIP Bell FSK CLIP BT DTMF CLIP n 0 OFF n 1 ON Roaming n 0 prohibited n 1 permitted Default setting Table of tones EEE im Dial tone up setting A U Mini Gate is ready to accept dial Busy tone short tone repeated aE E E E E Called partis busy doesnt exist not permitted etc Ringing tone long tone and pause ZOO ZO repeated Called part is ringing Waiting tone short tone repated with EE E E E EE quick cadence Mini Gate waiting for password insert Programming short tone with guick WEEE EEE EEE cadence i Programming mode of Mini Gate Confir
5. er The BLUE GATE will send a command immediately after acknowledge character dialling 8 Notes A Programming is only by tone dial DTMF Dont forget set even external line at PBX A Changes are valid after hang up only finishing of programming mode It is very important especially in acknowledge character changes till hang up you must use previous acknowledgement A After numbers dialing you must wait for confirming reguest insert acknowledge character and wait for confirming tone When you insert acknowledge charater before wont be accepted P Switch to programming mode is possible even in busy tone 9 Table of programming 0 JO n In n n Password nnnn to programming modeaccess 0 0 00 In In In In Memory x for permitted fix number 1 to 4 digits TTT EEE Reversal polarity n 0 OFF n 1 ON Acknowledge character setting n 0 Type of dial tone n n 0 permanent tone n 1 dial tone up table of tones n 2 dial tone of public lines operator Turning on combination for dialling to mobile phone n 0 combination turn off n 1 sending to mobile after 00 dialling Signalization to the call short tone each minute n 0 tone is turn off n 1 tone is turn on Restriction of call duration n 0 without restriction n 1 call duration restricted at 10 minutes n 0 start without PIN n 1 start with PIN Type of acceptable dial of telephone number n
6. mation inguiry 3 short tones 3 3 lt Inquiry to confirm inserted parametr Confirmation tone long tone a Parametr was saved correctly Minute tone short tone with 1 minute period Minute beep to inform about GSM call Call progress tone short tones with VE different freguency E Searching of called part LED signalling Permanent light lights up after 3 sec ofter power connection Power supply of unit Permanent light line OFF HOOK Doesnt light line ON HOOK Flashing in rhytm of busy tone Programming or PC connection mode Flashing in 2 sec period SIM is unreadable for example wrong PIN SIM not inserted etc Short lights off with period 2 sec GSM modul doesnt communicate to CPU 1 5 flashes with period 4 sec stand by mode Number of flashes signal strength Short flashes in period 2 sec Gate is not registrate to GSM network Quick flashing with different period GSM communication logging to net call data connection Technical parametres Type Operating position Operating conditions Dimensions mm Weight Part of power supply Supply voltage Power input Protection Safety group Analogue telephopne line telephone interface telephone conector Impedance Dial Billing Start and end of connection Supply conduction Current loop Resistance of subscribers conduction Ringing Signalization CLIP GSM mobile network 1800
7. nalogue line or so much big resistance in current loop for example longer cabel between PBX and Mini Gate Tle yellow LED communication to GSM is flashing up signal strength as same as green LED lights up Tle PBX hold pick up line of GSM Gate By incoming call you can remove this issue In other cases check PBX manual The Mini Gate works but call is disturbed by interference Incorrect position of antenna against telephone line Change antenna position Default you make by parametr 99 in programming mode via programming table at page 11 Alle LEDs flashing as same as tone types are mentioned in tables at the end of manual 5 USB The Gate is eguipped by USB port for direct control of GSM module Siemens TC35 or MC35 or MC39 for GPRS via virtual COM port The Gate you can further use ordinary GSM modem for data transmission internet connection or for SMS messages When unit is working as GSM modem then is busy for voice connection When you pick upthe line you will hear busy tone The unit is monitoring data transmission by modem The data transmission can not be permanent therefore the unit stays in data mode 10 seconds after finishing of data transmission Then is going back to Voice mode calling The same is when you are calling over unit It is busy for data transmission The optional sw supply to unit for sending and receiving SMS messages is SMS mail It is working under Outlook Outlook Expres O
8. pera etc And you can work with SMS as with normal e mails see manual for SMS mail It works in batches and allows programm communication interval 1 to 99 minutes to Mini Gate for sending and receiving SMS Due this we avoid situation that unit is permanentlky blocked by data mode for voice communication Further functionality of USB is monitoring Mini Gate operation It is possible record even incoming calls includes time and CLIP signal strength etc 6 CONFIGURATION The programming mode is set after acknowledgement dialing to Blue Gate In the analogue phone is waiting tone After password inserting is tone changing to programming tone Then you can programming each features of Blue Gate via table of programming Progress of programming Dial 2 digits number of programming feature Dial 1 to 4 digits number for feature value programming Wait for a tone of confirming reguest 3 short tones Confirm the feature by dialling acknowledgement F Wait for confirming tone Follow programming tone again Finish programming by hang up a phone 0000000 Example programming of new permitted fix numbers 02 to memory 09 Dial acknowledgement default is F In phone you are hearing waiting tone I E B B Dial password default 0000 Waiting tone is changing to programming tone HIHIHI Dial 1902 Wait for tone of confirming reguest 3 short tones Confirm the feature by dialling acknowledgement 4 Wait for confi
9. rming tone one long tone Finish programming mode by hang up a phone Warning After dialling of parametr value you have to wait for 3 short tones and then dial acknowledgement Wait for long tone confirm acceptation of this parametr 7 Notes to each parametres 11 19 When you programm some prefixes the Mini Gate 22 24 31 29 32 35 allows outgoing calls starts by those prefixes only The others will get busy tone When memories will be empty the calling wont be restricted default Memory of prefixes can content 1 digit only If you insert 1 digit only the Mini Gate will check first position only Rewriting of memory by storing of new fix numbers are old fix numbers erased Erasing of memory Memory you will erase by storing of nothing You dial only number of memory which you want erase and confim it very important feature is acknowledge character setting Default is When is used for PBX features you can change it on An analogue phones are not enable send which is very used in GSM In this case is possible to use combination 00 to send it to mobile phone This feature identificated connection of Mini Gate to external line at some type of PBX ex Siemens Hicom This feature is used for searching of antenna best position After feature activation you get tones immediatelly You end the feature by hang up The GSM phones reguested command to connection on inserted numb
10. then waiting for communication to GSM module via LED table communication off After cca 30 seconds the yellow LED start flashing up GSM signal strength via LED table When pick up connected analogue phone or call to Mini Gate from PBX the LED of analogue line lights up green LED In the phone is hearing dial tone of Mini Gate Itis ready to use The most often problems during Blue Gate compact installation gt All LED is not lighting Problem in power supply Check connection to main 230V as same as connection of adapter to Mini Gate gt The LED power supply lights When you make connection to Gate green LED is ON and in handset you hear busy tone Yellow LED flashing in period GSM modul doesnt communicate with CPU During work with USB could be programmed fix communication rate for GSM modul Use USB to programm rate on autobaudind 4 Note The yellow LED flashing in period PIN unreadable After calling to Mini gate you get busy tone The SIM card reguires PIN which is not preprogrammed or is preprogrammed wrongly The LED communication to GSM is flash shortly one for 2 sec After calling to Mini Gate you are hearing busy tone Mini Gate is not log into GSM network bad signal The yellow LED communication to GSM is flashing up signal strength After calling to Mini gate is not light up green LED is not light up and in analogue phone is guiet It interrupted conduction of a
Download Pdf Manuals
Related Search
Related Contents
Help System and User`s Guide Operating instructions Electronic level sensor LR7000 706105 / 00 SCX800HD-2 Torcia da taglio meccanizzato Plasmarc König KN-WS500 weather station Neuros Audio OSD 6011000 User's Manual Assembly and Operating Instructions for Outback TNS-100 - Teletechnique Programmation - Nogent-sur-Oise Copyright © All rights reserved.