Home alarm system User's manual - GLOBAL Export

image

Contents

1. which is suitable when hosts at home because indoor infrared alarm function is canceled while the gate magnetisms on the door and window are still in a state of monitoring Multi checked defense area Under the situation of defense or intelligent defense if two or more detectors that set up multi checked are all triggered within 30 seconds the main engine will give an alarm Therefore based on this pattern none of the infrared detectors will misinform the events Note Set up two or more than two defense areas to be multi checked and they should be set up respectively Delay alarm defense area When the defense area is triggered and need alarm the main engine can delay the alarm the concrete delay time is determined by the Setting up alarm delay moreover the warning behavior can be canceled during delayed time Delete defense area It means delete selected defense areas only for wireless defense areas Note when you input 8 99 6 all of the wireless defense areas will be deleted Repeat triggered defense areas When the detector is triggered once the system will not alarm immediately Only when it is triggered again within 5 30 seconds after the first trigger the system will alarm The selection of common defense area and intelligent defense area has no influence of choosing Mode 4 5 6 so you choose intelligent or common defense area while selecting anyone of Mode 4 5 6 at the same time However when you reselect Mo
2. 1 the main panel 1 wireless PIR detector 1 wireless door window detector 1 siren 2 remote controllers 1 adaptor 1 phone line 1 instruction manual Technical Parameters Main panel Operating voltage DC9V Average power AC DC exchanger 2A Wireless receiving distance lt 100M Operating Frequency 433 92 Operating voltage 9 12V 220 110VAC Outer Alarm Siren Volume 110 db Working Condition Temperature 10 C 40 C Humidity lt 90 Capacity for Wireless Device 160 Wireless door window Detector Power Supply DC12V inner 9V battery Static Current lt 20 uA Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Interval Distance 15 mm Working Condition Temperature 10 C 40 C Humidity lt 90 Press 3 to close arisen Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current lt 100 uA Transmission Current lt 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 Remote Controller Power Supply DC9V inner DC9V battery Static Current 0 Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Working Condition Temperature 10 C 40 C
3. magnetic stripe on the door and affix the gate magnetic emission box on the doorframe Pay attention to put the magnetic strip close to the side with indicator lights of the emission box during installation assuring proper alignment and the smaller distance the better Infrared detector installation The principle of infrared detectors is to sense people s movement through sensing infrared signals generated by bodies and the detection range is usually 5 12 meters Infrared sensor should be installed about 2 2 meters away from ground Aim straight at the detection ranges Moreover the infrared detector can be only installed in the room without facing the sunshine windows and other places where temperature is easy to change because the installed location may influence the detection range and accuracy Function settings All the settings can be carried out under the undefended situation with a long ring for all the proper operations while two short sounds for wrong settings Silent alarm 00 no alarm whistle for warning Vocalalarm 01 alarm whistles for warning Set up common alarm telephone numbers 1 5 set 1 5 groups telephone number 1 5 is the ordinal of the telephone number stands for telephone numbers Set up emergency phone numbers 6 2 The same method as above press alarm button of the main engine and the remote alarm button will call this group number Delete telephone numbers 1 6 D
4. Home alarm system User s manual Profile To better understand this product please read the user s manual carefully before using Features 1 ONS a E E ah 1 99 LED wireless defense zone with digital number to show the defense zone and with keypad on panel Auto dial six telephone numbers when alarming Can set the home arm and away arm functions Every defense zone can set independently arm disarm delay alarm and so on Have the password protection Can arm disarm listen in by calling the host phone number 7 can code 99 wireless detectors in total 8 With built in backup battery still work when power failure Brief introduction of system This alarm consists of main engine of alarm and various wireless connected accessories When people enter the defense region illegally the main engine will give sound of sirens and call the hosts so hosts can return home or inform neighboring relatives to cope with the instantly Also they can monitor the sound on the spot Alarm installation Insert the plug of telephone outside line into LINE2 of the main engine and connect LINE of the main engine with telephone using attached telephone wire of alarm Then joint up the power source and warning signal meanwhile the main engine will give a sound of B and light of the power source goes on which means the main engine starts working Gate magnetism installation Use the random equipped double side tape to stick a
5. Humidity lt 90
6. ain engine can cancel defense normally Delayed time of setting up defense Inputting 4 can start the delayed time of setting up defense which means the formal defense will begin after seconds when you press the button Here the range of is between 0 and 99 Although it is in the state of delayed defense it can enter defense situation immediately if you repress the defense button Open the alarm function when telephone lines disconnect 51 When phone lines disconnect or failure it will give alarm rings to inform Close the alarm function when telephone lines disconnect 5 0 means main engine will not detect telephone lines disconnection or fault Remote setup telephone ringing times 6 If the ring times calling local fixed line telephone above the setting times it will connect remote server automatically Here is the setting ring times while 0 means no remote setup Modify passwords 7 new password 4 numbers new password 4 numbers Use it when keyboard is locked and you forget password at the same time Recover factory settings 8 password The system will recover factory settings Clear telephone numbers vocal alarm alarm sounds cancel alarm delayed setting defense close the function of detecting disconnected telephone lines alarm ring time last for 5 minutes The instruction can not delete remote controller and defense area Password protection on the keypad The system has no
7. de 1 2 3 Mode 4 5 7 will be cleared Input password password The designing password is 0000 which 4 can be changed to another four numbers as the password Learning remote controller 0 The intelligent learning remote controller of main engine begin to count down 10 seconds When the remote or detector is triggered in 10 seconds the main engine can distinguish automatically and give a long sound presenting the location of remove memory which means successful study All of the code learning method is the same Learning detector 01 the intelligent learning remote controller of main engine Learning method is same as above Designated serial learning detector 8 Connect learning detector to the designated defense area number and is the defense number For example if you want to designate a detector to Defense Area 16 only input 8 16 Delete all of the remote controllers 0 2 means delete all of the remote controllers Delete all of the defense area detectors 8 99 7 means delete all of the defense area detectors Use remote controller to open and close the alarm sound 2 1 0 Alarm sounds for opening while buzzer sounds for closing Open crack proof function a il ag Open this function then none of the wireless remote controllers can cancel defense except for the cancel defense button of the main engine Close crack proof function 30 Close this function then remote controller of m
8. elete all the selected group telephone numbers Set up alarm delay 722 set up delay warning time in the delay mode zone in seconds Here stands for the number of seconds within the range between 0 and 99 Alarm ringing time 9 2 The alarm ringing time without human intervention after warning Here the range of is between 0 and 30 minutes Inquiry alarm defense area 0 9 Directly press 0 9 to inquiry the 10 latest alarm events and display alarm defense area 0 means the latest one The state of setting up defense area 8 0 7 Here stands for the serial number from 0 to 99 0 7 designates the setting mode of selected defense area 0 not use 1 common defense area 2 intelligent defense area 3 emergency defense area 4 multi checked defense area 5 delay alarm defense area 7 repeat triggered defense area For example press 8 2 2 then you can set up defense area 2 as the intelligent area Note When you input 99 it means all the wireless defense area will work according to this mode Emergency defense area No matter under the defended or undefended situations once triggered it will report to the police immediately which is suitable for the gas reaction smog reaction safe emergency accesses and other special occasions Intelligent defense area After selecting an area as intelligent defense one the defense area is not effective it is still effective under the normal defense area
9. ligent defense F1 for alarm when telephone lines disconnect F3 means there is no learning defense area 1 98 means wireless defense area L1 L8 means wired defense area 6 Operation methods of remote setup You can use any telephone to dial the numbers of main engine and it will put on automatically after system detecting the ring times you have been setup When you hear the beep input passwords two sounds when the password is wrong while when the wrong time is above 3 the phone will hang up automatically the original passowrd is 0000 and if it is correct you can have remote control of the system Please press after accomplish all operations then you can implement other operations and hang up telephone Press 1 to monitor the scene Press 2 to ring alarms Press 3 to close arisen Press 4 to arm Press 5 to disarm If the password is wrong or no any operations within 20 seconds it will hang up automatically Press 1 button once you can listen for 20 seconds 7 Processing method after receiving alarm In case of emergency main machine will dial the setup telephone numbers automatically and give alarm rings based on settings If the host s phone is in use or not able to connect the system will dial next alarm phone until it is dialed and hosts 7 confirm Press 1 to monitor the scene Press 2 to ring alarms Press 4 to arm Press 5 to disarm Standard components
10. password protection from factory people can arm disarm the system on panel without password If the people want to have this function the command is 11 after this need to enter passowrd the original password is 0000 then enter 0000 before arm and disarm To close this function by command 10 Application of alarm system 1 Set up defenses Press f button on remote controller or Set up defenses button on panel and the main engine will give a sound of B then the main engine enter the defense situation or delayed defense state 2 Cancel defenses Press m gt button on remote controller or Cancel defenses button on panel and the main engine will give two sounds of B then the indicator lamp dies out so the main engine is in a state of no defenses 3 Emergency alarm Press M button on remote controller or Alarm button on panel main engine will enter the state of emergency alarm instantly calling automatically and siren going off Press amp button on remote controller once is silent alarm while long press or two presses will open the siren 4 Intelligent defenses Press A button on remote controller or Intelligent button on panel then main engine will enter the state of intelligent defense or delayed defense 5 Status indication of main engine digital tube Indicate SF for defense CF for no defense 99 for emergency alarm bE for intel