Home
1641 / 1689 : User's Manual
Contents
1. Installed by Date Serviced by Tel Monitored by Tel Your account number Alarm transformer location on Circuit Location of Telephone Connections Spectra Keypads 43 9 0 Appendix A For Spectra 1689 LED Keypad Modules only Do not read the following if you have not read these sections e User Access Codes see section 3 4 on page 14 e System s Clock see section 5 6 on page 30 e Auto Arm Time section 4 9 on page 24 After entering the 3 digit section you wish to program the ARM1 and STAY1 will flash If a value is programmed the number corresponding to the first digit of the programmed value will also illuminate At this point you can begin entering the required data After entering a digit the number corresponding to the following programmed digit will illuminate and so forth For example if you wish to change User Code 004 from 123456 to 454545 after entering section 004 number 1 will turn on Press the 4 key and number 2 will turn on then press the 5 key and number 3 will turn on OR After entering the desired 3 digit section and before entering any data press the ENTER key to access the Data Display Mode The ARM1 and STAY1 Lights will illuminate Once in the Data Display Mode pressing the ENTER key will scroll through the digits of the current section and the BYP MEM amp TRBL Lights will flash When viewing the last digit in the section pre
2. Partition 1 Partition 2 Zone and Partition Entry Description 1or2 Byp Stay Force 24Hr Delay 01 02 Keyswitch Y UI N Type 03 Fire Zone YL N Delayed YLI N 04 05 06 07 08 09 10 38 User s Manual Zone and Partition Entry Description 1or2 Byp oly korce 24Hr Delay 11 12 13 14 15 16 Access Codes For security reasons write only the user s name and not his or her access code 4 DigitCodesl 6 Digit Codes Partition Arm PGM User and Name 1or2 Byp Stay Force Only Only 001 1 amp 2 Vv Vv System Master Code Default 123456 002 Master Code 1 003 Master Code 2 a 004 005 Spectra Keypads 39 Partition Arm PGM User and Name Tor Byp Stay Force Only Only 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 40 User s Manual Partition Arm PGM User and Name ior2 B
3. Do not delete the System Master Code Refer to the warning in section 3 1 on page 13 for more information For the 1689 LED Keypad Module also refer to Appendix A on page 44 Table 1 User Code Sections Section User Codes Mooi JUser Code 001 System Master Code 002 User Code 002 Master Code 1 003 User Code 003 Master Code 2 004 to 047 User Code 004 to User Code 047 048 User Code 048 or Duress Code Spectra Keypads 15 4 0 Arming amp Disarming Take full advantage of your Spectra system by familiarizing yourself with all the arming methods If your system is not partitioned section 2 7 on page 12 everything is considered as belonging to Partition 1 4 1 Exit Delay After entering a valid arming sequence an Exit Delay Timer will provide you with enough time to exit the protected area before the system arms The keypad may beep during the Exit Delay 4 2 Disarming amp Deactivating an Alarm To disarm an armed system or an alarm enter your access code An entry point like the front door will be programmed with one of two Entry Delay Timers When an entry point is opened the keypad will beep until you disarm the system Your alarm system will not generate an alarm until this timer elapses Any user can disarm a partition they have been assigned to except users assigned with the Arm Only Option To disarm alarms generated by a Delayed Fire Zone please refe
4. 2 3 4 Press the ENTER key Enter MASTER CODE Enter 100 Enter the desired TIME A If the keypad is configured for International time enter the time using the 24Hr clock i e 6 15 p m 18 15 Proceed to step 6 B If the keypad is configured for U S time enter the time using the 12Hr clock Proceed to step 5 After entering the time step 4B press the 1 key to set the time in a m or the 2 key to set the time in p m for the U S time format 6 Use the A or V keys to select the day 7 Press ENTER to save and exit If the time on your keypad is displayed with a m or p m your keypad is configured with the U S time format 5 7 Keypad Settings 1641 LCD Keypad Modules Only You can modify the keypad s setting to suit your needs How do I modify my keypad s settings 1 Press and hold the 6 key for 3 seconds 2 Choose one Press 1 Backlight the keypad s light 7 is the brightest 2 Contrast character intensity 7 is the lightest 3 Scroll time between messages 7 is slowest 3 Press the A or V keys to modify your keypad s settings 4 Press the ENTER key to save 5 Return to step 2 to modify another setting or press the CLEAR key to exit 5 8 The Help Menu 1641 LCD Keypad Modules Only The 1641 LCD Keypad module comes with a Help menu that is divided into two sections which the installer can use to enter information abou
5. 15 p m 18 15 For the 1689 LED Keypad Module also refer to Appendix A on page 44 PAR 5 AooxK unm For Spectra 1641 LCD Keypad Modules How do I program the Auto Arm Timer 1 Press the ENTER key 2 Enter MASTER CODE 3 Enter 101 for Partition 1 or 102 for Partition 2 4 Enter the desired TIME A If the keypad is configured for International time enter the time using the 24Hr clock i e 6 15 p m 18 15 B If the keypad is configured for U S time enter the time using the 12Hr clock Proceed to step 5 5 After entering the time step 4B press the 1 key to set the time in a m or the 2 key to set the time in p m for the U S time format If the time on your keypad is displayed with a m or p m your keypad is configured for the U S time format A 60 second Exit Delay section 4 1 on page 16 will start before the system arms At this point Auto Arming can be cancelled by entering your access code Spectra Keypads 25 4 9 2 No Movement Auto Arming Your panel can be programmed to arm the system and or send a report if no zone activity occurs for a pre programmed amount of time This is a particularly useful feature when supervising an individual with chronic health problems or a person who lives alone 5 0 Additional Features Each keypad must be Chimed and Muted separately Chime Zones and Keypad Muting must be re programmed if your system suffers a tota
6. Bypass Programming section 4 7 5 on page 23 To remove the Bypass feature from a zone in step 3 enter the zone number again or press FORCE to erase all current entries For Spectra 1641 LCD Keypad Modules When zones are bypassed Zone s Bypassed BYP to View will appear on the screen How do I bypass zones 1 Press the BYP key 2 Enter your ACCESS CODE see note below 3 Enter the two digit zone number of the desired zone i e zone 3 03 or use the A or V keys to view the zones and press the BYP key when the desired zone appears on the screen 4 Press the ENTER key to exit To remove the Bypass feature from a zone in step 3 re enter the two digit zone number of the desired zone or press the BYP key when the bypassed zone appears on the screen If you have access to both partitions press the key Le corresponding to the desired partition 1 or 2 4 6 1 Bypass Recall Feature After disarming the system the bypass entries are erased The Bypass Recall feature reinstates the previous bypass Spectra Keypads 21 entries saved in memory This eliminates the need to manually re program the bypass entries every time you arm the system How do recall bypass entries 5 Press the BYP key 6 Enter your ACCESS CODE see the note on page 21 7 Press the BYP key 8 Press the ENTER key 4 7 One Touch Arming One Touch arming allows you to ar
7. Notwithstanding the preceding paragraph the Seller s maximum liability will be strictly limited to the purchase price of the defective product Your use of this product signifies your acceptance of this warranty BEWARE Dealers installers and or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller 2001 2004 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice One or more of the following U S patents may apply 6215399 6111256 5751803 5721542 5287111 5119069 5077549 5920259 and 5886632 Canadian and international patents may also apply Spectra and WinLoad are trademarks or registered trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries Spectra Keypads 45 Notes PARADOX EC UR YSTEMS 780 Industriel Blvd bat nae Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 2313 www paradox ca Printed in Canada 09 2004 SPEK EU06
8. directly to your monitoring station We strongly suggest that you inform your monitoring A Station of the trouble and allow them to service your system The keypad can be programmed to emit a BEEP every 5 seconds whenever a new trouble condition has occurred Press the TRBL key to stop the Trouble Beep For Spectra 1689 LED Keypad Module When a trouble condition occurs the TRBL symbol will illuminate How do I access the Trouble Display 1 Press the TRBL key The TBL symbol will flash and number s corresponding to the trouble s will illuminate 2 Read the corresponding explanation of the trouble from the Trouble List on page 8 If no repair instructions are given call your monitoring station for repairs 3 Press the CLEAR key to exit Spectra Keypads 7 For Spectra 1641 LCD Keypad Module When a trouble condition occurs System Trouble TRBL to View will appear on the screen How do access the Trouble Display 1 Press the TRBL key Trouble View System Trouble will appear on the screen 2 Use the A or V keys to view the Trouble s Read the corresponding explanation from the Trouble List If no repair instructions are given call your monitoring station for repairs 3 Press the CLEAR key to exit Trouble List After you press the TRBL key e On the 1689 LED Keypad Module the numbers 1 to 16 will illuminate for the correspondi
9. 6 ON Partition armed OFF Partition disarmed Zone Display The numbers 1 to 16 correspond to zones 1 to 16 respectively When illuminated zones are open or breached Spectra Keypads 3 2 2 2 For the Spectra 1641 LCD Keypad Module The LCD liquid crystal display is a 32 character screen that displays messages that can be customized to your needs Figure 3 Overview of the 1641 LCD Keypad Module The messages on the LCD screen will display the system s status and guide you through the system s operations When arrows appear in the LCD screen use the arrow buttons to scroll through the menu 2 3 Auditory Feedback When you enter information on the keypad it will guide you with beep tones You should be familiar with these Confirmation Beep When an operation i e arming disarming is successfully entered on the keypad or when the system switches to a new status mode the keypad produces an intermittent beep tone BEEP BEEP BEEP BEEP Rejection Beep When the system reverts to previous status or when an operation is incorrectly entered on the keypad it will emit a continuous beep tone BEEEEEEEEP 4 User s Manual 2 4 Alarm Memory Display All zones where alarms have occurred will be stored in memory The system will erase the contents of the Alarm Memory every time the system is armed For Spectra 1689 LED Keypad Modules If an alarm has occurred on a zone the MEM symbol wi
10. Arming eee eee eee teeeeteeeeeeeaes 5 0 6 0 7 0 8 0 9 0 4 7 1 One Touch Regular Arming e 4 7 2 One Touch Stay Arming ssi 4 7 3 Fast Exit eee 4 7 4 One Touch Force Arming 4 7 5 One Touch Bypass Programming 4 8 Keyswitch Arming cere 4 9 AUuto Arming ee ee eeeeeeeeeeeeee 4 9 1 Timed Auto Arming vee 4 9 2 No Movement Auto Arming sessen Additional Features ccccessessseeneeteees 26 5 1 Programming Chime Zones esseere 26 5 2 Keypad Muting s ien oiana iar 27 5 3 Panic Ala MS irinin e 28 5 4 PGM Button Programmable Outputs 0 28 5 5 Quick Function KeyS s ssssssseseeeerrerrrerrerrerrnrreerrene 29 5 5 14 TeStREPOM seccvecveiscascevearagstevestvascesachestteevecveenessbes 29 5 5 2 Call PC E EEA 29 5 5 3 Answer PC ceee EEO ETT 29 5 5 4 Cancel Communication 00 0 eee 29 5 6 Programming Time and Day clock 30 5 7 Keypad Settings cee eeeecesseeeeeeeeseeeeeeeeeeeeateaes 31 5 8 The Help Menu ce eeeeeeseeenseeseeeeeeeesereeeereneees 31 Fire Ala tM S se ocsocecccccedecez secs coteseteec2sckctceetececezctentsee 33 Testing amp Maintenance cccsssecseseeeesseeees 37 System Checklist cccsseeeeesseeeeeseseeeeeeeneeeees 38 ADDONCIX A 5 oe csc oc ee ad stecectdeeaccndsuccentceeecseneieeaseacce 44 1 0 Introduction Thank you for selecting the Spectra Security System from Paradox Se
11. a SPECTRA LCD and 16 Zone LED Keypads stan aR ado x 1689 1641 16 Zone LED Keypad LCD Keypad User s Manual eRe a aT Table of Contents 1 0 2 0 3 0 4 0 INTFOGUCTION vissctecicecenesccedtvineesncetdvieceiecerecetetice 1 Basic Operation iiciceccsnecscccccscnesstevcnsteecctescntcucnuce 2 2 1 Keypad Indicator Lights 0 0 0 0 eee eee eeeeees 2 2 2 Visual Feedback cee ee eee eee teens teseeteeeeeaees 3 2 2 1 For the Spectra 1689 LED Keypad Module 3 2 2 2 For the Spectra 1641 LCD Keypad Module 4 2 3 Auditory Feedback eee cece tees rene eeneeeeeees 2 4 Alarm Memory Display 0 c eee eee terete 2 0 EVEN ISK merar ar D aeae AASE EEA 2 6 Trouble Display cee 2 7 WPANIMOMUNG ea aaaea oe rE a atte Programming Access Codes s ccseseeeeees 13 3 1 System Master Code Default 123456 13 3 2 Master CodeS 3 3 Duress Code ceee 3 4 Programming Access Codes Arming amp Disarming ccsscsssseseesseeseeeneees 16 AA Exit Delay ss iscictiiccceritivesieainnitiesieeeniisettnaiis 16 4 2 Disarming amp Deactivating an Alarm 0 c 16 4 3 Regular Arming eceee eee eeeeeeeeeeseeeeeeeeeeeeaes 17 4 4 Stay Arming 4 4 1 Instant APMing esisiini iseia 4 5 Force Arming sects ccscesscetsassasuaiaasasscceasned eceeaiesscaaraes 4 6 Manual Bypass Programming 4 6 1 Bypass Recall Feature 4 7 One Touch
12. and hold the FORCE key for 3 seconds see the note on page 21 to bypass any open Force zones For details on Force arming refer to section 4 5 on page 19 4 7 5 One Touch Bypass Programming Press and hold the BYP key for 3 seconds see the note on page 21 to access Bypass Programming Mode section 4 6 on page 20 Spectra Keypads 23 4 8 Keyswitch Arming A keyswitch can be used to arm and disarm the system A keyswitch is programmed to Stay arm section 4 4 on page 17 or Regular arm section 4 3 on page 17 and is assigned to a specific partition A keyswitch can function as a Maintained or Momentary keyswitch To arm the system using a Maintained keyswitch set the keyswitch to the ON position To disarm the system set the keyswitch to the OFF position To arm the system using a Momentary keyswitch set the keyswitch to the ON position then turn it back to the OFF position Repeating this sequence will disarm the system 4 9 Auto Arming The Spectra alarm system can be programmed to automatically arm upon the following two conditions 4 9 1 Timed Auto Arming You can program the time your alarm system will automatically arm itself everyday For Spectra 1689 LED Keypad Modules How do I program the Auto Arm Timer 1 Press the ENTER key 2 Enter MASTER CODE 3 Enter 101 for Partition 1 or 102 for Partition 2 24 User s Manual 4 Enter the desired TIME using the 24Hr clock i e 6
13. area occupied by a keypad For example when arming and the motion detector is a Force zone the system will allow you to arm even if the zone is open How do I Force arm 1 Close zones in the desired partition except Force zones 2 Press the FORCE key 3 Enter your ACCESS CODE Spectra Keypads 19 If you have access to both partitions section 2 7 on page 12 B 4 Press the key corresponding to the desired partition 1 or 2 For both partitions press the other key after the confirmation beep Force arming can also be activated by using One Touch Force arming section 4 7 4 on page 23 4 6 Manual Bypass Programming Manual Bypass Programming allows you to program the alarm system to ignore deactivate specified zones the next time the system is armed For example you may wish to bypass certain zones when workers are renovating part of your establishment Once the system is disarmed the bypass entries are erased For Spectra 1689 LED Keypad Modules When zones are bypassed the BYP symbol will illuminate How do I bypass zones 1 Press the BYP key 2 Enter your ACCESS CODE see the note on page 21 3 Illuminate the number s corresponding to the zone s you want to bypass by entering the two digit zone number i e zone 3 03 4 Press the ENTER key to save and exit 20 User s Manual Manual Bypass Programming can also be activated by using One Touch
14. curity Systems Ltd The Spectra Security System will give you peace of mind by providing reliable security protection Spectra can realize your dreams of home automation such as controlling garage doors lights heating temperature and much more Consult your installer to take full advantage of your Spectra system s capabilities This advanced technology security system provides you with reliable security protection and powerful features that anyone can use without memorizing complex and confusing codes The system consists of the Spectra control panel one or more Spectra keypads modules various input devices i e motion detectors door contacts etc and various output devices i e bells sirens lights etc The elegant and user friendly Spectra 1689 LED Keypad Modules and 1641 LCD Keypad Modules allow you to easily access your security system s functions and provide you with an easy to understand display of your security system s alarm and operational status All of the actions performed in your security system will be executed and displayed through the keypad Therefore before using your security system we highly recommend that you read this manual carefully and have your installer explain basic system operation to you Spectra Keypads 1 2 0 Basic Operation The Spectra 1689 LED and 1641 LCD Keypad Modules function in the same way but display visual feedback differently This section will provide an overview of the keypa
15. de and many of your system s features can be assigned to either Partition 1 Partition 2 or both partitions If the system is not partitioned all zones user codes and A features will be recognized as belonging to Partition 1 12 User s Manual 3 0 Programming Access Codes Access codes are personal identification numbers that allow you to enter certain programming modes arm or disarm your system as well as activate or deactivate PGMs The Spectra security system supports the following e 1 System Master Code 2 Master Codes 45 User Access Codes including 1 Duress code For information on how each access code can arm or disarm the system refer to the System Checklist on page 38 3 1 System Master Code Default 123456 The System Master Code can arm or disarm any partition using any of the methods described in this section and can create modify or delete any user access code see Programming Access Codes on page 14 Do not delete the System Master Code in section 001 If A you do the System Master Code will be lost you will not be able to re program it and your system will have to be serviced by a technician 3 2 Master Codes Master Code 1 is permanently assigned to Partition 1 and can be used to create modify or delete user access codes see Programming Access Codes on page 14 that are assigned to Partition 1 Spectra Keypads 13 Master Code 2 is permanently assigned to Partition 2 except when partitio
16. ds g Many of the features in your system must be enabled by the installer If the feature is not programmed the keypad will emit a rejection beep and the action will be cancelled Refer to System Checklist on page 38 for details 2 1 Keypad Indicator Lights The state of each light on the Spectra keypad modules represents a specific condition in your system as shown in Figure 1 Figure 1 Overview of Indicator Lights AC Light ON AC power is present OFF Power failure STATUS Light When Green ON All zones closed w OFF Zone s open FLASH During Exit Delay When Red LCD keypads only CiD ON System armed SLOW FLASH Stay armed FAST FLASH Alarm 2 User s Manual 2 2 Visual Feedback 2 2 1 For the Spectra 1689 LED Keypad Module The numbers and symbols on the keypad s screen communicate your system s status as shown in Figure 2 Figure 2 Overview of the 1689 LED Keypad Module r Trouble Display ON Trouble s occurring Arm Lights red for Regular and Force arming Arm 1 for Partition 1 Arm 2 for Partition 2 wen Alarm Memory Display ON Alarm 2 occurred Bypass Programming ON Zone s bypassed ON Partition armed OFF Partition disarmed FLASH Partition in alarm Stay Lights red gt for Stay and Instant arming Amm Stayt Arm Stay2 Byp Mem Trei Stay 1 for Partition1 Stay 2 for Partition 2 123456789 10 1112 13 14 15 1
17. iencing trouble press the 9 key after step 2 from the Trouble Display see How do I access the Trouble Display on page 7 or page 8 10 Telephone Line Monitoring Failure The system has not detected the presence of a telephone line for more than 30 seconds 11 Fire Zone Trouble A wiring problem on the fire zone is occurring 12 Module Loss A module is no longer communicating with your system 13 Wireless Transmitter Supervision Loss A wireless transmitter is no longer communicating with its Spectra Keypads 11 receiver or its batteries are disconnected To view on which zones the Wireless Transmitters are experiencing trouble press the MEM key after step 2 from the Trouble Display see How do access the Trouble Display on page 7 or page 8 16 Keypad Fault If for any reason your keypad is no longer communicating with your alarm system the keypad will emit four consecutive beeps at 3 second intervals Press any key on the keypad to terminate the beeping sequence When communication is restored the keypad will resume its functions 2 7 Partitioning Your Spectra system is equipped with a partitioning feature that can divide your alarm system into two distinct areas identified as Partition 1 and Partition 2 Partitioning can be used in installations where shared security systems are more practical such as a home office or warehouse building When partitioned each zone each user co
18. l power loss 5 1 Programming Chime Zones A Chime Enabled zone will advise you every time it is opened by causing your keypad to beep For Spectra 1689 LED Keypad Modules How do chime zones 1 Press amp hold the 9 key for 3 seconds 2 Illuminate the numbers corresponding to the zones you want to Chime by entering the two digit zone number For example to chime zone 2 enter 0 then 2 The keypad will automatically save once the 2 digit zone number is entered 3 Press the ENTER key to exit To remove the Chime feature from a zone in step 2 enter the 26 User s Manual zone number again so the number extinguishes or press FORCE to remove Chiming from all zones programmed to Chime When you program Chime Zones once you press and hold the 9 key the ARM1 STAY1 ARM2 STAY2 BYP MEM and TRBL symbols will flash Any zones that are already Chimed will also illuminate Zones that remain off or extinguished are not Chimed For Spectra 1641 LCD Keypad Modules How do I chime zones 1 Press amp hold the 9 key for 3 seconds 2 Enter the two digit zone number of the desired zone or use the A or V keys to view the zones and press the FNC1 key when the desired zone appears on the screen The keypad will automatically save once the 2 digit number is entered 3 Press the CLEAR key to exit To remove the Chime feature from a zone in step 3 re e
19. ll illuminate After disarming the system press the MEM key to illuminate the number symbols corresponding to the zones that were in alarm To exit the Alarm Memory Display press the CLEAR key For Spectra 1641 LCD Keypad Modules If an alarm has occurred on a zone Zone s in Memory MEM to view will appear on the LCD screen After disarming the system press the MEM key Use the A or V keys to view the zones that were in alarm To exit the Alarm Memory Display press the CLEAR key Spectra Keypads 5 2 5 Event List 1641 LCD Keypad Modules Only The Event List will record all the actions that occur in the system How do I view the Event List 1 Press the MEN key 2 Press the FNC2 key 3 Use the A or V keys to view the Event Screens 4 Press CLEAR twice to exit Each event that occurs generates two Event Screens see Figure 4 Once you enter the Event List the time and the day the event occurred and what event occurred will scroll on the screen As you press the V key the next pair will scroll Figure 4 Example of Event Screens Time of the event The event that occurred ARM WITH USER or SYSTEM TROUBLE USER O01 PART G01 BATTERY FAILURE Who initiated The partition where the event the event occurred 6 User s Manual 2 6 Trouble Display Your alarm system continuously monitors fourteen possible trouble conditions Most of these trouble conditions can be reported
20. m the system without using an access code 4 7 1 One Touch Regular Arming Press and hold the ENTER key for 3 seconds see the note on page 21 to arm all zones in the partition You can use this feature to allow specific individuals like service personnel i e cleaners to arm without giving them access to any other alarm system operations For details on Regular arming refer to section 4 3 on page 17 4 7 2 One Touch Stay Arming Press and hold the STAY key for 3 seconds see the note on page 21 to arm all zones not defined as Stay zones For details on Stay arming refer to section 4 4 on page 17 22 User s Manual 4 7 3 Fast Exit When the system is already Stay armed This feature will allow you to exit already armed premises and keep the system armed Exit and Stay Arm Press and hold the STAY key for 3 seconds see the note on page 21 to start the Exit Delay see page 16 After the Exit Delay has elapsed the system will return to Stay arming Exit and Regular Arm Press and hold the ENTER key for 3 seconds see the note on page 21 to start the Exit Delay see page 16 After the Exit Delay has elapsed the system will switch to Regular arming see page 17 Exit and Force Arm Press and hold the FORCE key for 3 seconds see the note on page 21 to start the Exit Delay see page 16 After the Exit Delay has elapsed the system will switch to Force arming see page 19 4 7 4 One Touch Force Arming Press
21. ng trouble s e On the 1641 LCD Keypad Module the heading s will appear on the screen 1 No or Low Battery Trouble The backup battery is disconnected or the battery voltage is getting low 2 Wireless Transmitter Battery Low The battery voltage in one or more Wireless Transmitters is 8 User s Manual getting low Also the device s yellow light will flash 3 Power Failure The system has detected a loss of AC power This trouble usually occurs during a power failure If a power failure is not occurring in your establishment and this trouble appears contact your monitoring station for service 4 Bell PGM2 Disconnected Trouble Any device connected to the Bell or PGM2 output is no longer connected to your alarm system 5 Bell Current Failure During an alarm the bell output which uses a fuseless circuit will automatically shut down if the current exceeds a predetermined value When the system is disarmed the current is cut from the bell output and the Trouble warning may extinguish but the Trouble may re occur during the next alarm if the situation is not corrected 6 Auxiliary Current Failure The auxiliary output which supplies power to your alarm system s accessories uses a fuseless circuit to protect the power supply against current overload and automatically shuts down if the current exceeds a predetermined value 7 Communication Failure Your alarm system if monitored could not communicate wi
22. ning is disabled Master Code 2 will be assigned to Partition 1 and can be used to create modify or delete user access codes see section 3 4 that are assigned to the same partition Master Codes cannot modify or delete user access codes Le assigned to both partitions Only the System Master Code can modify or delete user access codes assigned to both partitions 3 3 Duress Code If you are forced to arm or disarm your system entering the access code assigned to User 048 will arm or disarm the system and immediately transmit a silent alert Duress Code to the monitoring station Lo Must be enabled by your installer 3 4 Programming Access Codes Your system can use either 4 or 6 digit access codes see page 39 where each digit can be any value from 0 to 9 Six digit codes are considered more difficult to crack and therefore more secure Avoid programming simple or obvious access codes such as your telephone number address or codes such as 1234 14 User s Manual How do program Access Codes 1 Press the ENTER key 2 Enter your MASTER CODE 3 Enter 3 digit SECTION see Table 1 below 4 Enter a new 4 or 6 digit ACCESS CODE 5 Press the CLEAR key to exit How do I delete Access Codes 1 Repeat steps 1 to 3 see above 2 Press the FORCE key once for each digit in the access code 4 or 6 times until the keypad emits a confirmation beep then press the CLEAR key to exit
23. nter the two digit zone number of the desired zone i e to remove Chime from zone 2 enter 0 then 2 or press the FNC1 key when the chimed zone appears on the screen 5 2 Keypad Muting When muted the keypad will only emit the confirmation beep rejection beep and beep when a key is pressed Therefore when muted the keypad will not beep during an alarm Press Spectra Keypads 27 and hold the CLEAR key for 3 seconds to enable or disable Keypad Muting If the keypad emits a confirmation beep Keypad Muting is enabled for that keypad If the keypad emits a rejection beep the feature is disabled 5 3 Panic Alarms In case of an emergency the Spectra system can provide three panic alarms that can immediately generate an alarm after simultaneously pressing and holding two specific keys for three seconds Based on your needs these panic alarms can generate audible alarms sirens or bells or silent alarms and can communicate specific messages to your monitoring station For instance pressing 1 and 3 can mean call the police or anything you require Press and hold keys 1 and 3 for the police Press and hold keys 4 and 6 for a medical alarm Press and hold keys 7 and 9 for a fire alarm 5 4 PGM Button Programmable Outputs Your Spectra system may include one or more programmable outputs PGMs When a specific event or condition occurs in the system the PGM can be used to reset smoke detectors activa
24. r to Fire Alarms on page 33 How do I deactivate an alarm Enter your ACCESS CODE 16 User s Manual How do disarm the system For a Stay or Instant armed system go to step 2 1 Enter through a designated entry point i e front door 2 Enter your ACCESS CODE If you have access to both partitions section 2 7 on page 12 3 Press the key corresponding to the desired partition 1 or 2 For both partitions press the other key after the confirmation beep 4 3 Regular Arming This method will arm all the zones in the selected partition How do I Regular arm 1 Close all zones in the desired partition 2 Enter your ACCESS CODE If you have access to both partitions section 2 7 on page 12 3 Press the key corresponding to the desired partition 1 or 2 For both partitions press the other key after the confirmation beep Please note that Regular arming can also be activated using Auto Arming section 4 9 on page 24 a keyswitch section 4 8 on page 24 or One Touch arming section 4 7 on page 22 4 4 Stay Arming This method allows you to remain in the protected area while partially arming the system Stay zones are zones that are Spectra Keypads 17 bypassed when Stay arming For example when you go to sleep at night doors and windows can be armed without arming other zones like motion detectors How do I Stay arm 1 Close all zones in
25. ssing the ENTER key will automatically advance to the next section Press CLEAR to exit 44 User s Manual Warranty Paradox Security Systems Ltd Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product s inability to operate Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications Returns must include proof of purchase and be within the warranty period In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold
26. t may cost you your life Finally having at least one working smoke alarm dramatically increases your chances of surviving a fire And remember to practice a home escape plan frequently with your family Spectra Keypads 35 Providing a Fire Warning System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements 36 User s Manual 7 0 Testing amp Maintenance With the system disarmed and the READY light ON activate motion detectors by walking in the protected area Open and close protected doors and verify that the corresponding key illuminates Your installer can advise you of the best way to test your particular system Do not use open flame or burning materials to test your fire detection devices Contact your installer for safe methods of testing your system Under normal use your system requires virtually no maintenance other than regular testing It is recommended that the standby battery be changed every three years Speak to your installer about the necessary tests and at what frequency they should be performed Spectra Keypads 37 8 0 System Checklist Zone Description Is this system partitioned Yes No
27. t your system Zone Info and Notes The Notes section contains general notes messages or important information such as emergency numbers and tips Spectra Keypads 31 The Zone Info section contains general zone information How do I access the Help menu 1 Press the HELP key 2 Press the 1 key to access Zone Info or press the 2 key to access Notes 3 Press the A or V keys to scroll through the programmed notes or information 4 Press the CLEAR key to exit 32 User s Manual 6 0 Fire Alarms Upon a fire alarm the bell siren will emit three squawks at 2 second intervals until silenced or reset by entering a valid access code If the zone is a Delayed Fire Zone there is a delay before the system contacts the monitoring station This will prevent unnecessary reporting of false alarms If there is no fire condition contact your monitoring station immediately to avoid an unnecessary response What do I do if a delayed fire zone was set off accidentally 1 Press the CLEAR key within 30 seconds of the alarm 2 Try to correct the problem 3 If the problem persists the alarm will sound again Press the CLEAR key again These steps will instruct the system to delay reporting the fire alarm to the monitoring station see Figure 5 on page 34 Spectra Keypads 33 Figure 5 Delayed Fire Zone Event Sequence Delayed Fire Zone is triggered Bell siren acti
28. te light switches in your home or office open close garage doors and much more A PGM can also be programmed to activate whenever the FNC1 key is pressed and held for 3 seconds 28 User s Manual 5 5 Quick Function Keys Upon request of your installer or monitoring station you may have to perform one of the following Press 5 5 1 Test Report ENTER MASTER CODE MEM If your system is monitored by your monitoring station this feature will send a test report code to the monitoring station 5 5 2 Call PC ENTER MASTER CODE BYP Will initiate a call to the monitoring station that is using the WinLoad software 5 5 3 Answer PC ENTER MASTER CODE FORCE Will force your security system to answer a call made by your monitoring station that is using the WinLoad software 5 5 4 Cancel Communication ENTER MASTER CODE STAY Cancels all communication with the WinLoad software if it has been initiated Spectra Keypads 29 5 6 Programming Time and Day clock For Spectra 1689 LED Keypad Modules How do I program the System Clock 1 2 3 4 Press the ENTER key Enter MASTER CODE and enter 100 Enter the time using the 24Hr clock i e 6 15 p m 18 15 Press the CLEAR key For the 1689 LED Keypad Module also refer to Appendix A on page 44 30 User s Manual For Spectra 1641 LCD Keypad Modules How do I program the System Clock 1
29. th the monitoring station Spectra Keypads 9 8 Timer Loss Your alarm system s clock must be reprogrammed This is the only trouble that we recommend that you correct For Spectra 1689 LED Keypad Module How do I reprogram the clock 1 Perform steps 1 and 2 from How do I access the Trouble Display on page 7 2 Press the 8 key 3 Enter the desired TIME using the 24Hr clock i e 6 15 p m 18 15 For the 1689 LED Keypad Module also refer to Appendix A on page 44 For Spectra 1641 LCD Keypad Module How do I reprogram the clock 1 Perform steps 1 and 2 from How do I access the Trouble Display on page 8 2 Press the 8 key 3 Enter the desired TIME A If the keypad is configured for International time enter the time using the 24Hr clock 6 15 p m 18 15 Proceed to step 5 B If the keypad is configured for U S time enter the time using the 12Hr clock Proceed to step 4 10 User s Manual 4 After entering the time step 3B press the 1 key to set the time in a m or the 2 key to set the time in p m for the U S time format 5 Use the A or V keys to select the day 6 Press ENTER to save and exit If the time on your keypad is displayed Ly with a m or p m your keypad is configured with the U S time format 9 Tamper Zone Wiring Failure A wiring problem is occurring on one or more zones To view which zones are exper
30. the desired partition except Stay zones 2 Press the STAY key 3 Enter your ACCESS CODE If you have access to both partitions section 2 7 on page 12 4 Press the key corresponding to the desired partition 1 or 2 For both partitions press the other key after the confirmation beep Stay arming can also be activated using Auto Arming section 4 9 on page 24 a keyswitch section 4 8 on page 24 or One Touch arming section 4 7 on page 22 4 4 1 Instant Arming After Stay arming the system and during its Exit Delay press and hold the STAY key for 3 seconds You should hear a confirmation beep The system is then Instant armed Therefore any armed zone that is breached will immediately generate an alarm 18 User s Manual If you have access to both partitions To Instant arm one partition 1 Press the STAY key 2 Enter your ACCESS CODE 3 Choose a partition 4 Press and hold the STAY key for 3 seconds To Instant arm both partitions 1 Press the STAY key 2 Enter your ACCESS CODE 3 Press the 1 key 4 Press 2 5 Press and hold the STAY key for 3 seconds 4 5 Force Arming Force arming allows you to rapidly arm the system without waiting for all zones in the system to close During Force arming a Force zone is considered deactivated until it closes then the system will arm that zone Force arming is commonly used when a motion detector is protecting the
31. vated Transmission of the report delayed for 30 seconds Problem Yes corrected within 30 seconds Has CLEAR been pressed within 30 seconds Generate alarm and alert Security Company Bell siren silenced Report transmission delayed an additional 90 seconds Problem corrected END Alarm Disabled 34 User s Manual Minimizing Fire Hazards The three most common causes of fires Cooking is the leading cause of home fires in the U S It s also the leading cause of fire injuries Cooking fires often result from unattended cooking and human error rather than mechanical failure of stoves or ovens Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resistant bedding and upholstered furniture are significant fire deterrents Heating is the second leading cause of residential fires However heating fires are a larger problem in single family homes than in apartments since the heating systems in single family homes are often not professionally maintained Fire Safety Tips In the event of a fire escape first then call for help Develop a home fire escape plan and designate a meeting place outside Make sure everyone in the family knows two ways to escape from every room Practice feeling your way out with your eyes closed Never stand up in a fire always crawl low under the smoke and try to keep your mouth covered Never return to a burning building for any reason i
32. yp Stay Force Only Only 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 Spectra Keypads 41 Partition Arm PGM User and Name 1or2 Byp Stay Force Only Only 046 047 048 Duress Y N Special Keys and Features LI ENTER One Touch Regular arming is activated LI STAY One Touch Stay arming is activated LI FORCE One Touch Force arming is activated C BYP One Touch Manual Bypass Programming is activated Panic Alarms 1 amp 8 Police or Silent L Audible L Off 4 amp 6 Aux or Silent L Audible L Off 7 amp 9 Fire or Silent L Audible L Off PGMs PGM 1 PGM 2 PGM 3 42 User s Manual System Timers Enter and exit your premises through the designated doors Exit Delay 1 Partition 1 sec time to exit site Exit Delay 2 Partition 2 sec time to exit site Entry Delay 1 sec time to disarm before alarm enter through zone Entry Delay 2 sec time to disarm before alarm enter through zone Alarm will activate siren or bell for min Other Information
Download Pdf Manuals
Related Search
Related Contents
SECTION 2 INSTALLATION - Sea Fujitsu ESPRIMO C5731 Fisher & Paykel Oven OB60S9DECP User's Manual Operating Instructions Software TLB-CON10-Scope V1.1 IMAG Drift Calculator v1.1 User manual 取扱説明書~ Preventive Maintenance Guidelines Small Bus, Van, Wagons User Manual MANUEL D`UTILISATION ET D`INSTALLATION Copyright © All rights reserved.