1. WF35 uk INSTALLATION MANUAL AND OPERATING INSTRUCTIONS d INSTALLATIONS UND GEBRAUCHSANWEISUNG fr NOTICE D INSTALLATION ET D UTILISATION nL INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING WESTFIRE dansk ingeni rkunst d INSTALLATIONS UND GEBRAUCHSANWEISUNG 18 fr NOTICE D INSTALLATION ET D UTILISATION nL INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING WESTFIRE WESTFIRE 2013 WF35 1 0 uk UK Installation manual and operating instructions WF35 uniq 35 uniq 35 inset This manual refers to the stove types listed above which have been tested in accordance with EN13240 Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing and using fireplaces and multi fuel stoves please see the relevant building regulations that apply to the country in which WESTFIRE UNIQ 35 has been approved These instructions cover the basic principles to ensure the satisfactory installation of the WESTFIRE UNIQ 35 stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or reg
2. and old and or infirm people The fireguard should be manufactured in accordance with BS 8423 2002 Fireguards for use with solid fuel appliances WESTFIRE WF35 uk Operating Your stove Westfire uniQ 35 Controls flue collar secondary air slider 2 125mm r Slide left closed Slide right open door handle Pull to open Starting point 1st catch Primary air control Primary Coal Control ridding Lever Position 1 min Position 3 min ridding grate Position 2 max Position 4 max Push and Pull motion Primary air Control settings Burning wood position 1 to position 2 When burning wood use primary air control from position 1 fully pushed in to position 2 when controls stops midway Do not move beyond this position for wood burning Burning wood position 3 to position 4 When burning coal the primary air control drops to position 3 midpoint location operate and regulate your stove between position 3 and 4 fully pulled out uk The first lighting of your stove The heat resistant paint on your stove will cure and harden the first time you light your appliance The curing process produces a good deal of smoke and odour it is therefore important that the first time you light your stove the room should be well ventilated During the process it is important to open and close the stove door periodically every 30mins during the first couple of firings therefore preventing the door seal cord around the door from sticking and
3. uk Annual service CONTIUNED 7 The paint lacquer can wear thin in exposed places due to overheating This and other lacquer damage maybe repaired using a Westfire Senotherm paint lacquer spray available from your Westfire dealer 8 If appliance is to be dormant for several months summer leave open all air controls to allow a flow of air and thus reducing probably of corrosion Chimney cleaning 1 The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood and other fuels It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period 2 If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire 3 In situations where it is not possible to sweep through the stove the installer will have provided alternative means such as a soot door After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush Aerosols Aerosols are flammable and therefore dangerous to use around a lit stove Do not use aerosols sprays near your lit stove The use of any aerosol is dangerous and care must be take in handling aerosols Warning note Properly installed operated and maintained this stove will not emit
4. a ration en tirant compl tement sur le tirette de r gulation d air sur le c t gauche La meilleure fa on d allumer le po le est d utiliser des briquettes d allumage N utilisez jamais d alcool d essence ou d autres liquides inflammables pour allumer votre po le Placez de petits morceaux de bois en travers du po le au dessus des briquettes d allumage Une fois que le feu a bien pris placez deux morceaux de bois de 30cm environ pesant en tout environ 1 2 kg Apr s environ 5 minutes fermez la tirette de r gulation d air sur le c t gauche et fermez la tirette de r gulation d air au centre environ 50 Le rechargement de biche se fait une fois par heure puissance nominale Pour combustion r duit lente il faut simplement ajouter de petites quantit s de bois moins souvent et fermez le levier de l air au centre de plus de 50 Les po les WF35 est concu pour fonctionner par intermittence le bois doit tre rajout souvent et le po le n est pas con u pour tre chauff en continu Le po le WF 35 est pr vu pour fonctionner par intermittence le bois doit tre rajout souvent et le po le n est pas con u pour tre chauff en continu au cas o la chemin e est en feu Fermez la trappe d a ration et la porte puis composez le 112 ou le num ro des pompiers POsitiOns der gLage des tr aPPes dur ant L utiLisation air secondaire Wf 35 Ouverture 50 Il est n cessaire de se familiariser ave
5. adjacent to thehearth should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions If the stove is to be installed on a wooden floor it must be covered with a non combustible material at least 12mm thick in accordance with Building Regulations Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber Combustion air supply In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air This is particularly necessary if the room is double glazed ora flue draught stabiliser is operating in the same room as the appliance The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Air inlets must be positioned in such a way that they cannot be blocked An air inlet may be a vent the vent must be open and the capacity of the vent sufficient when the stove is lit or a fresh air system linked to the stove The WESTFIRE UNIQ 35 are fitted as standard with a closed air supply collar this enables the stove to take all combustion air primary secondary and tertiary directly from outside with 80mm pipe from the stove There are no European rules regarding the m
6. and push handle firmly to the second closed position The WF Uniq 35 door handle has two positions position 1 holds the door slightly ajar for starting and position 2 is fully closed Recommended fuels Good quality wood is the most important factor in your stove working efficiently and cleanly Always use dry split firewood The dryness of the firewood plays an important role since the use of wet wood results in poor fuel economy and may cause a tarry sooty film on the internals of the stove Within a smoke control area you must use an SE model and only wood or Authorised solid fuels are permitted The Westfire Uniq 35 is tested to burn wood and smokeless coal Wood briquettes can also be burnt but load weight should be strictly adhered to For a full list of suitable fuels check with the official solid fuels approvals body HETAS or Solid Fuel Association Do not overload stove as this can cause excessive heat and damage the stove ALWAYS KEEP FUEL LOAD BELOW TERTIARY PORTS AT REAR OF STOVE uk Only use fuels approved for use on heating stoves do not burn liquid fuels drift wood finished wood sawn wood pallet wood chipboard plywood varnished wood or plastic coated wood wood treated with preservatives or house hold waste DO NOT EXCEED SPECIFIED FUEL WEIGHTS Do not burn house coal Do not burn Household Waste this appliance is not an incinerator House Coal and Petroleum Coke arenot suitable for use on this stove its use will in
7. coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is NOT designed to be used with the door open the stove door must be kept closed except when lighting the stove adding firewood or removing ash in order to prevent flue gases from escaping Door not operate appliance with ash pan removed or open Lighting your appliance Quality Firelighters should be used when lighting the stove Never use mentholated spirit petrol or other flammable liquids Lighting your stove with firelighters will be more reliable and easier than using paper UNIQ 35 reload Weights 1 hour reload 2 hour reload Wood Hardwood Logs less than 20 moisture 1 2kg 400mm N A smokeless Coal Briquettes registered Only N A 1 1kg To light your stove Wood 1 Place a few smaller pieces of dry wood kindling in the stove on top of the nontoxic firelighters place one or two small dry split 4 split logs on top 2 Fully open the secondary air control above the stove door on right hand side Fully open primary air control at base left of stove Pull out riddling arm fully at base right of stove if necessary The Uniq 35 stoves air controls are now fully open 3 Light the firelighters and push door to closed position and close handle to 1st position this will allow a small gap in the door for more air to be supplied to stove during ignition period 4 When the flames are established and the
8. fire is burning brightly push the door latch to position 2 fully closed 5 Once fire is burning brightly again close the primary air control Push in riddling arm This will close off the primary air to the stove If the stove begins to falter after the primary is closed open primary control again and leave until fire has established then close 6 The fire should now be fully established and burning brightly At this stage close secondary air control by 50 this is the operational setting For the stove to burn cleanly and efficiently plenty of secondary air is needed do not be tempted to shut the fire down too early as this may cause smoke At nominal heat output expect to refuel your stove once an hour The WESTFIRE UNIQ 35 stove is equipped with a manual regulating control for secondary air this is designed to ensure a plentiful supply of oxygen during firing It is important therefore to not fully close the secondary air control When lit the stove will get very hot and due care must therefore be exercised Please use a glove and operating tool supplied when operating air controls and riddler Re f ueLing wood To re fuel your stove in the cleanest way Only refuel your stove when flames have died down and you have glowing embers Uk Before refuelling open secondary air control fully open primary air control fully Open door add two pieces of split wood measuring approximately 30cm with a combined weight of 1 2kg Close the doo
9. fully open the new refuel charge does not require any boost air to establish combustion Refuelling on to a low fire bed If there is insufficient burning material in the firebed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Fuel Overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Operation with door left open can cause excess smoke Westfire smoke control stoves should not be operated with the door left open Dampers left open Operations with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with air controls appliance dampers or door left open except as directed in the instructions uk To light your stove smokeless Coal 1 Place a few smaller pieces of dry wood kindling in the stove on top of the nontoxic firelighters place one or two small dry split and small quantity of Smokeless coal 2 Fully open the secondary air control above the stove door on right hand side Fully open primary air control at base left of stove Pull open coal switch Pull out riddling arm fully at base right of stove The Uniq 35 stoves aircontrols are now fully open 3 Light the fireligh
10. nominale warmtevermogen is 4 3 kW WF35 heeft een keuringsgewicht van 110 kg Minimale rookafvoer de kachel is gekeurd met een rookafvoer van 12 Pa Max rookafvoer 25 Pa De rookgasmassastroom is 4 0 g sec De rookgastemperatuur is bemeten op 244 WF35 hebben een voven uitgang De schoorsteen kan worden voorzien van een regelklep in het rookkanaal van de haard zodat de afvoer door de schoorsteen op dagen met hevige wind geregeld kan worden De klep mag niet helemaal gesloten kunnen worden maar moet een vrij oppervlak hebben van minstens 20 cm van het totale openingsoppervlak van het nL kanaal Er kunnen ook andere vormen van afvoerbegrenzers worden toegepast bijvoorbeeld door buiten de haard om lucht de schoorsteen binnen te laten WF35 kunnen worden aangesloten op schoorstenen waarop ook andere warmtebronnen zijn aangesloten Gasgestookte warmtebronnen moeten altijd hun eigen schoorsteen hebben waarop geen andere warmtebronnen mogen zijn aangesloten BedieningsHandLeiding Als u de houtkachel voor het eerst aansteekt zal de hittebestendige verf harden waardoor er nogal wat stank en rook ontstaat Zorg daarom voor een goede ventilatie De eerste paar keer dat u de haard aansteekt moet u ook de deur een klein eindje open laten en hem pas weer sluiten als de haard koud is Daarmee wordt voorkomen dat de afdichtingsstrip aan de haard vastkleeft en loslaat Wanneer de hittebestendige verf gehard is moet de deur gesloten blijven
11. oder ein am Ofen angeschlossenes Frischluftsystem handeln Alle Kamin fen von Westfire sind mit einer Rauchumlenkplatte ausgestattet sodass der Weg den der Rauch nimmt m glichst lang ist ansCHLuss an den sCHOr nstein Der Schornstein muss einen Durchmesser von mindestens 15 cm aufweisen was einer Offnung von 175 cm entspricht Er muss zudem eine Hohe haben die ausreichend Zug gewahrleistet und daf r sorgt dass es zu keiner Rauchbel stigung in unmittelbarer Nahe kommt Schlie lich muss er mit einer leicht zug nglichen Reinigungsklappe versehen sein Das Modell WF 35 ist nach den europ ischen Normvorschriften 13240 zugelassen Die Nennw rmeleistung betr gt 4 3 kw WF 35 Erprobungsgewicht von 110 kg Min Schornsteinzug Pr fwert 12 Pa Max Schornsteinzug 25 Pa Abgasmassen storm 4 0 g s Rauchgastemperatur 244 Forderdruck bei NW 0 10 Mbar CO Emission Bez 13 02 0 12 Das Modell WF 35 verf gt ber eine Rohranschlussm glichkeit oben Das Rauchrohr ist mit einer Regulierklappe erh ltlich die es erm glicht den Schornsteinzug an Tagen mit starkem Wind zu regulieren Sie darf sich nicht vollst ndig schlie en lassen d h der freie Durchgang muss mind 20 cm betragen Eine Verringerung des Schornsteinzugs kann auch auf andere Weise herbeigef hrt werden etwa durch Luftzufuhr im Schornsteinbereich Das Modell WF 35 l sst sich auch an Schornsteine anschlie en an die andere Heizquellen angesch
12. uniq 35 uniq 35 standard pedestaL inset Stove Frame 4 sided Frame 3 sided Height 590mm 985mm 555mm 625mm 590mm Width 390mm 390mm 390mm 480mm 480mm depth 350mm 350mm 345mm Closed combustion as std Yes Yes Yes et uk uk Distance to Combustible materials Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions Westfire WF uniq35 Distance to combustible materials rear 200mm Distance to combustible materials side 200mm The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove Hearth The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently supported The WESTFIRE UNIQ 35 stove has been tested and are suitable to be installed on a 12mm non combustible plate suchas Westfire 12mm glass plates or 20mm slate plates Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls
13. 0 Parts of products for which any manufacturer other than Westfire stoves provides warranties 11 Removal and re installation cost Products repaired or replaced under the warranty are covered only for the remainder of the original warranty period Any claim under this warranty must in the first instance be submitted to the authorised dealer from whom the stove was purchased If such dealer has ceased trading or is no longer an authorised dealer please write to Westfire Stoves indicating the model number size and serial number the place price and date the stove was uk WESTFIRE WF35 purchased including the original sales receipt the date it was installed and any other information which Westfire Stoves may reasonably require The warranty does not affect your statutory rights and in particular Westfire Stoves does not seek to limit liability for death or personal injury caused by Westfire Stoves negligence or the negligence of its employees agents or subcontractors Westfire Stoves will not in any circumstances whether under the warranty or otherwise be responsible for loss or damage you suffer that is not a foreseeable result of its breach of this warranty RE INSTALLING BRICKSET 1 Ensure base grate is in 5 Fit top turbulence baffle by 6 Fit baffle by placing on top of position securing baffle plate under at rear brick and securing with 2 2 Place rear brick to back of front and inserting pin at rear steel pins into the sid
14. behalve tijdens het aansteken het bijvullen van brandstof en het verwijderen van restmaterialen om te voorkomen dat er rookgas ontsnapt Voordat u de haard aansteekt moet u het luchtsysteem openen door de luchtstang helemaal naar buiten te trekken en de luchtinlaat in de asla te openen Bij het aansteken van de kachel dient u de hendels voor primaire en secundaire luchttoevoer volledig open te zetten Om de kachel aan te steken maakt u gebruik van aanmaakblokjes gebruik nooit spiritus benzine of andere brandbare vloeistoffen Plaats enkele kleine stukken hout aanmaakhoutjes in de kachel boven op de aanmaakblokjes Als het vuur goed brandt kunt u twee stukken goed gedroogd hout toevoegen van ongeveer 30 cm met een totaalgewicht van cirra 1 2kg op Na zo n vijf minuten sluit u de primaire luchttoevoer en de secundaire tot 50 00 Voor afgifte van de nominale warmte zult u de kachel eens per uur moeten vullen Als u minder warmte en of langzamere verbranding wenst vult u de kachel minder vaak of met kleinere hoeveelheden U kunt dit ook regelen door de luchttoevoer tot een minimum meer dan 50 te sluiten De Westfire Uniq 35 is ontworpen voor intermitterende verbranding regelmatig met hout vullen de kachel is niet ontworpen voor gebruik voor 24 uur WF35 kachels zijn voorzien van een regelventiel voor secundaire lucht waarmee voor zuurstof voor de verbranding kan worden gezorgd Bij het stoken van de houtkachels zullen alle oppe
15. bij garantiereparaties De garantie vervalt bij onbevoegde veranderingen aan de warmtebron Gebruik bij reparatie uitsluitend reserveonderdelen die door Westfire ApS worden aanbevolen nL 3 DK 6800 D T F 4575225352 F 45 7522 1352 WWW W DK F W FORHANDLER WESTFIRE 2013
16. c le r glage de l air secondaire dans la mesure o la qualit de la chemin e sa hauteur et la qualit du combustible utilis tout comme les conditions ext rieures jouent un r le important mais on peut galement voir si la combustion se d roule correctement Si votre po le se recouvre int rieurement d une suie dure et brillante c est le signe que la combustion est insatisfaisante Dans ce cas un apport d air secondaire est n cessaire Il est important de contr ler les conditions de tirage avant d allumer le po le il suffit pour cela de chiffonner un morceau de papier journal de le placer dans la chambre combustion et de l allumer Si la fum e passe bien a travers la chemin e le tirage est satisfaisant fr COMBustiBLe N utilisez jamais de bois toxique comme des planches d agglom r du bois peint ou trait Utilisez toujours du bois sec Le niveau de s cheresse du bois joue un r le capital car lorsque le bois est humide la combustion co te plus cher et il y a formation de bistre Le bois fra chement coup contient entre 60 et 70 d eau ce qui le rend absolument impropre comme combustible Il doit d abord tre entrepos et mis s cher au vent sous un auvent pendant deux ans avant de pouvoir servir comme bois de chauffe entr etien La cendre doit tre enlev e intervalles r guliers Le po le ne doit tre nettoy que lorsqu il est froid II doit tre essuy ext rieurement avec un chiffon sec L
17. controls until the fire confirmed to be exhausted The chimney and flue ways should then be inspected and cleaned by a professional chimney engineer before and further use Permanent air vent The stove requires a permanent air vent to the room or a direct connection to the closed air port at the rear of the stove This is to provide adequate air supply in order for the stove to operate safely and efficiently uk In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not under any circumstances be shut off or sealed trouble shooting 1 fire Will not Burn check a the air inlet is not obstructed in any way b that chimneys and flueways are clear c thata suitable fuel is being used d that there is an adequate air supply into the room e thatan extractor fan is not fitted in the same room as the fire 2 fire Blazing out of control check a ifthe door are tightly closed b the air control is turned down to the minimum setting c the air controls are closed and that it is not prevented from closing completely by a piece of ash d a suitable fuel is being used do not burn waste wood e the door seals are in good condition f ifthe chimney draft may be too strong g check ash pan seal and h check for ash below ash pan causing pan to not seat correctly and clean out 3 soot forms on t
18. d Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements Using your stove in a smoke control area Only specific SE models are suitable for smoke control areas see page 4 alterations should not be attempted Westfire smoke control stoves should not be operated with the door left open The SE models are able to burn wood logs and Authorised solid fuels in a smoke control area The refuelling procedure allow the newly charged fuel to burn with the secondary air control set at maximum for up 3 to 4 minutes After this period with flames from the logs fully established close the secondary air supply to the low output setting When operating at high output secondary air set
19. e bricks stove holes uppermost 3 Fit side brick close to door slide under location point at top of top 4 Fit second side brick be tween rear brick and front side brick Spare parts WF Uniq 35 parts listing for most commonly used parts Uniq 35 std uniq 35 pedestal uniq35 inset Description Code Comments Brick set WF35brickset Consisting of 2x side bricks 1x rear brick 1x lower baffle brick 1 x upper baffle brick Base grate WFONEBASEGRATE Inner riddling grate WFONEINGRATE Ashpan WF35ASHPAN Door Door rope seal WF35DRS Door glass WF35GLASS Tool WF ONETWO TOOL Glove WFglove uk de instaLLatiOns und geBr auCHsanWeisung Westfir e WF35 sOCkeL insatz Wir begl ckw nschen Sie zum Erwerb Ihres neuen Westfire Kaminofens Damit Sie viel Freude daran haben bitten wir Sie diese Gebrauchsanweisung sorgf ltig durchzulesen denn so lassen sich Probleme vermeiden Wir machen darauf aufmerksam dass bei der Installation alle einschlagigen Verordnungen und Normvorschriften einzuhalten sind Wenn Sie sich bez glich Aufstellung Anschluss und Betrieb des Modells WF 35 eingehender informieren m chten verweisen wir auf das Faltblatt Brandst ttenverordnung das Sie bei Ihrem Fachh ndler oder bei dem f r Sie zust ndigen Schornsteinfegermeister anfordern k nnen Dort k nnen Sie sich auch ber das ordnungsgem e Befeuern informieren aufstell und ansCHLussanLe
20. e des r parations sous garantie Avertissement il est interdit de proc der des modifications non autoris es de ce syst me En cas de r paration utilisez uniquement des pi ces d tach es recommand es par Westfire 5 nL instaLLatieHandLeiding en geBr uiksaanWijzing Westfir e WF35 Hartelijk gefeliciteerd met uw nieuwe houtkachel van Westfire ApS Om zoveel mogelijk plezier van uw nieuwe houtkachel te hebben en om problemen te voorkomen verzoeken we u deze instructies te lezen We wijzen u erop dat u zich bij de installatie van de warmtebron aan alle plaatselijke verordeningen moet houden inclusief de verordeningen die naar nationale en Europese normen verwijzen Als u meer informatie wilt hebben over het installeren en stoken met kachels of houthaarden kunnen we u verwijzen naar de brochures Bouwreglement in het desbetreffende land waarin WF35 zijn goedgekeurd en Correct stoken die beide worden uitgegeven door de Centrale Directie Bouwzaken en die verkrijgbaar zijn bij uw houtkacheldealer of schoorsteenveger PLaatsingsHandLeiding instaLLer en Bij het installeren van uw houthaard dient u zich te houden aan een aantal wetten en bepalingen in het Bouwreglement Deze bepalingen staan in het Bouwreglement Volgens dit reglement moeten brandbare vloeren bij gesloten vuurplaatsen minstens 30 cm voor de stookopening en minstens 15 cm naar elke kant bedekt zijn De onderlaag moet van onbrandbaar materiaal zijn bijvoorbeeld
21. een staalplaat een glasplaat tegels of een natuurstenenplaat De vloeren waarop de houtkachels geplaatst gaan worden moeten voldoende draagvermogen hebben Afstanden tot brandbaar materiaal zoals aangegeven op het EN 13240 plaatje achter op de houthaard achtekant cm zijkant cm afstand tot meubilair voorkant cm Wf 35 20 cm 20 cm 80 cm Er zijn geen regels voor de afstand tot onbrandbare wanden maar in verband met het reinigen adviseren we 10 cm achter de haard De verbranding vraagt om lucht en Achterkant cm en moet Zijkant cm an verse lucht zijn naar de kamer waar de kachel staat Het toevoerkanaal voor verse lucht moet op een plaats zitten waar het niet geblokkeerd kan worden Dat kan zijn in de vorm van een ventiel het ventiel moet open staan en over voldoende capaciteit beschikken als de haard brandt of een verseluchtsysteem dat met de kachel is verbonden Alle houtkachels van Westfire zijn voorzien van een rookkeerplaat die ervoor zorgt dat de weg die de rook aflegt lang genoeg is sCHOOr steenaansLuiting Er moet altijd gebruik worden gemaakt van een schoorsteen met een diameter van minimaal 15 cm overeenkomend met een opening van 175 cm2 De schoorsteen moet zo hoog zijn dat er voldoende afvoer mogelijk is en de rook niet hinderlijk is voor de omgeving De schoorsteen moet ook een gemakkelijk toegankelijk reinigingsluik hebben WF35 zijn goedgekeurd volgens de Europese norm EN 13240 Het
22. either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury Stove paint aerosols Paint aerosols are flammable and therefore dangerous to use around a lit stove Be sure to allow aerosol spray paints to dry and ventilate the room well before lighting the stove The use of any aerosol around lit stove is dangerous and care must be take in handling aerosols uk Westfire Uniq 35 Model choice uniq 35 standard uniq 35 PedestaL uniq 35 inset 50mm base 400mm pedestal 3 sided frame 4 sided frame Closed combustion Yes Yes Yes Yes Stove Performance amp testing Westfire Uniq 35 models have been approved in accordance with EN 13240 stove model efficiency Weight nominal heat output CO 13 02 Wood coal Wood smokeless fuels Wood coal uniq 35 standard 80 3 76 80kg 4 3 KW 3 7KW 12 17 uniq 35 pedestal 80 3 76 110kg 4 3KW 3 7KW 12 17 Preparatory Work and safety Checks important Warning important Warning This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room Chimney Chimney Connection flue diame
23. en Durch berhitzung kann es an bestimmten Stellen zu Lacksch den kommen Sch den dieser oder anderer Art lassen sich mit Senotherm Lack aus der Spraydose beheben der im Fachhandel erh ltlich ist Beh lter f r Asche m ssen aus nicht brennbarem Material bestehen und Asche darf nicht mit anderem brennbaren Abfall in Ber hrung kommen Der Feuerraum ist mit Platten der Fa Skamol ausgekleidet Da sich diese Platten mit der Zeit abnutzen m ssen sie ausgetauscht werden was im brigen auch f r die Rauchumlenkplatte gilt Wenn man ein Holzst ck zu heftig in den Ofen wirft kann es passieren dass eine Skamol Platte einen Riss bekommt Das wirkt sich jedoch nicht auf die Verbrennung aus sofern die Rauchumlenkplatte nicht beteiligt ist Offensichtlich stark verschlissene Platten m ssen ausgetauscht werden Dies gilt auch f r Platten mit mehreren Rissen Bei berhitzung des Kaminofens m ssen Luftklappe und T r geschlossen werden Betr ieBsst r ungen Wenn die Glasscheibe verru t liegt das vermutlich an feuchtem Holz oder daran dass das Feuer zu wenig Sekund rluft bekommen hat Brennt das Holz zu schnell ab kann das daran liegen dass der Schornsteinzug zu stark oder die T r undicht ist Gibt der Ofen zu wenig W rme ab kann die Verwendung von nassem Holz die Ursache sein Rauch oder Geruchsbel stigung kann auf schlechten Schornsteinzug zur ckzuf hren sein Pr fen Sie ob Rauchrohr und Schornstein verstopft sind und die Sc
24. en St ckes Zeitungspapier erfolgen das in die Brennkammer gelegt und angez ndet wird Zieht der Rauch gut durch den Schornstein ab ist alles in Ordnung Br enn HOLZ Verwenden Sie niemals mit Giftstoffen belastetes Holz Spanplatten oder gestrichenes bzw impr gniertes Holz sondern stets gut getrocknete Holzscheite Der Trocknungsgrad des Holzes spielt eine gro e Rolle denn feuchtes Holz w rmt nicht nur schlecht sondern f hrt auch zu Versottung Da frisch gef llte B ume 60 70 Wasser enthalten eignet sich Holz hiervon nicht zum Heizen Es ist davon auszugehen dass Holzscheite von frisch gef llten B umen 2 Jahre lang unter einem Halbdach lagern m ssen bevor sie verheizt werden k nnen War tung und PfLege Der Aschenkasten sollte regelm ig entleert werden Eine Reinigung sollte nur bei erkaltetem Ofen vorgenommen werden Die Au enfl chen des Ofens werden mit einem trockenen Lappen abgewischt Einmal im Jahr sollte der Ofen auch innen gr ndlich sauber gemacht werden Hierzu werden Asche und ggf Ru und Teerreste aus dem Feuerraum entfernt Die Rauchumlenkplatte wird herausgenommen da sich r ckseitig Schmutz und Ru ablagern Da die T rdichtungen nach l ngerer Betriebszeit undicht werden k nnen sind sie zu berpr fen Wurde der Ofen l ngere Zeit nicht benutzt ist er vor Inbetriebnahme auf guten Zug zu berpr fen Ferner sollten Ofen Rauchgasrohr und Schornstein regelm ig durch einen Fachmann inspiziert werd
25. es WF35 sont homologu s et la brochure sur l utilisation correcte du bois de chauffe toutes deux disponibles chez votre revendeur de po le ou chez votre ramoneur notice d instaLLatiOn et utilisation L installation de votre po le est soumise certaines lois et dispositions de la reglementation d urbanisme qui doivent tre respect es Pour plus de d tails nous vous invitons consulter la reglementation d urbanisme Celle ci mentionne que pour les foyers ferm s les sols inflammables doivent tre prot g s sur une surface d au moins 30 cm devant l ouverture du foyer et d au moins 15 cm sur les c t s La protection doit tre constitu e d un mat riau non inflammable comme une plaque en acier ou en verre des carrelages ou une plaque en ardoise synth tique Les sols sur lesquels sont install s les po les doivent tre d une port e suffisante pour supporter le poids du po le La distance entre le po le et le mat riau inflammable est indiqu e sur l Ecriteau EN 13240 situ derri re le po le arri re cm C t cm distance avec les meubles plac s devant cm cm Wf 35 20 cm 20 cm 80 cm Pour les murs non inflammables aucun r glement ne sp cifie la distance autoris e mais nous recommandons un espace de 10 cm derri re le po le pour pouvoir le nettoyer La combustion demande de l air et il est donc n cessaire d avoir un apport d air frais suffisant dans la pi ce o le po le est instal
26. formance unless the crack grows and rick break down o 4 Clean glass regularly do not allow build up of deposits regular condensation and acid deposits from combustion cause ceramic glass to whiten and crack Do not slumber smokeless coal or wood Clean glass with a lint free cloth and hot soapy water do not use an aggressive cleaner If you have persistent stubborn marks please use a ceramic glass cleaner Thoroughly dry the glass after cleaning 5 Clean the outside of your stove with a dry lint free cloth 6 Check seals for sign of fraying Annual service The inside of the stove should be serviced cleaned once or twice a year depending on amount of use Your local supplier will be able carry out a full service on your appliance The following steps should taken 1 Clean the inside remove all ash soot and tar residue from the combustion chamber Remove insulated chamber panels and baffle dirt and soot will collect behind it and this must be cleaned out N heck the quality of all insulated panels and replace any which are badly damaged 3 Replace stove rope seals gt a heck glass is correctly seated and glass seals are in good condition 5 Check air controls 6 Check flue ways the flue pipe connection and the chimney should be checked regularly by a qualified engineer The chimney should also be checked for blockages before relighting the stove if it has not been used for an extended period of time
27. fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice The most common cause of fume emission is flue way or chimney blockage For your own safety these must be kept clean at all times CO alarm Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS8423 2002 Chimney fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air controls on your stove to minimum and tightly close the door of the stove Call the fire department Closing the air should cause the chimney fire to go out but do not open the fire door or
28. grate assemblies firebricks glass and glass assemblies ash trays and sealing materials such as sealing rope Consumable parts will require periodic replacement 2 Senotherm painted surfaces 3 Damage resulting from installation and usage other than as described in Westfire stovess installation and operation instructions or if the installation does not conform to local building and fire and safety regulations 4 Defects or faults caused by local conditions such as draught problems and chimney defects 5 Damage resulting from over firing the appliance over firing can be identified by warped plates and areas where the paint pigment has been burned off or by chipping cracking bubbling as further described in the operation manual 6 Damage caused by use of the wrong type of fuel 7 Damage caused by modifications or repair other than as expressly authorised by Westfire Stoves or by the user or any other party other than Westfire stoves 8 Damage made while the stove is in transit Any appliance so damaged must not be installed or operated as this may damage any claim you may have against the carrier authorised dealer Please contact the authorised Westfire stoves dealer from whom you bought the stove 9 Damage arising where the stove has been used for commercial business or resale purposes nor shall we have any liability to you for any loss of profit loss of business business interruption or loss of business opportunity 1
29. he window a The firewood may be too wet b the intake of secondary air may be insufficient c fire not hot enough 4 the stove fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the height of the chimney in relation to the surroundings 6 soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient IMPORTANT NOTES general Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly Hetas Ltd approval This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level single tick approval for burning wood logs only as detailed in list of recommended fuels above Approval does not cover the use of other fuels either alone or mixed the recommended fuels listed nor does it cover instructions for the use of other fuels Guarantee Every Westfire stove is designed and built with great care and with the finest materials Ensuring quality control is an integral part of the production process Westfire stoves have a 5
30. hornsteinh he den rtlichen Verh ltnissen angemessen ist Eine Versottung des Schornsteins kann durch Heizen mit feuchtem Holz oder zu geringe Zufuhr von Sekund rluft beim normalen Betrieb entstehen gar antie Auf den neven Kaminofen werden 5 Jahre Garantie auf Fabrikationsfehler gew hrt ihre r echnung gilt als Nachweis f r das Datum des Kaufs die garantie erstreckt sich nicht auf sch den die sich aus berhitzung durch falsche Bedienung nicht sachgem en Anschluss oder u ere Einwirkungen ergeben Ausgenommen sind ferner Verschlei teile sowie Kosten f r Transport oder Auf Abbauarbeiten im Zuge von Garantie Reparaturen Die Garantie erlischt bei unbefugten technischen nderungen am Ofen Bei Reparaturen sind ausschlie lich von der Fa Westfire ApS empfohlene Ersatzteile zu verwenden fr fr nOtiCe d instaLLatiOn et d utiLisatiOn Westfir e WF35 Nous vous f licitons pour l achat de votre nouveau po le fabriqu par Westfire ApS Pour en profiter pleinement et vous viter toute difficult nous vous invitons lire attentivement cette notice Nous attirons votre attention sur l obligation de respecter tous les r glements locaux dont ceux qui se rapportent aux normes nationales et europ ennes lors de l installation du po le Pour plus d informations sur l installation et l utilisation de la chemin e ou du po le vous pouvez consulter la brochure sur la r glementation d urbanisme dans le pays o les mod l
31. inimum distance to non flammable walls Westfire recommend leaving a gap of at least 10 cm behind and to sides of stove Flue and air intake positions uniq 35 uniq 35 uniq 35 standard Pedestal inset distance from front to centre of top flue exit n a n a 240mm distance from rear to centre of top flue exit 120mm 120mm n a distance from floor to centre of external air intake 115mm 505mm 65mm uk Westfire insulated chambers The WESTFIRE UNIQ 35 stove is lined with vermiculite heat deflection panels and baffles these panels are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove These baffles should not be removed other than for cleaning the stove Any panels showing significant ware should be replaced Connection to chimney The WESTFIRE UNIQ 35 stoves are factory set up with a top flue outlet only the flue outlet can be altered on the inset model by removing the collar and rotating 180 degrees and re bolting This will give a collar which is now at a 45 degree angle Care should be taken to ensure an airtight fit when refitting collar This collar allows connection to either a stainless steel chimney liner or a prefabricated factory made insulated metal chimney Westfire DO NOT recommend installation of this appliance directly into a masonry chimney Commissioning and handover On completion of the installation allow a suitable period of time for any fire ce
32. int rieur du po le doit tre nettoy une fois par an Pour cela il faut retirer les cendres et les restes ventuels de suie et de goudron de la chambre combustion L inverseur de fum es doit tre retir car les salet s et la suie ont tendance s accumuler derri re Les joints de la porte finissent par s user avec le temps et ils doivent tre v rifi s Le po le le raccord des gaz de combustion et la chemin e doivent tre examin s r guli rement par un technicien qualifi Apr s une longue p riode sans utilisation il faut v rifier que la chemin e est libre de toute obstruction avant d allumer le po le nouveau Aux endroits expos s le rev tement du po le peut s user cause de la surchauffe Cette usure de m me que les autres dommages dans le rev tement peut tre r par e en utilisant une peinture Senotherm sp ciale en spray disponible chez tous les revendeurs de po les La chambre combustion est recouverte de plaques Skamol en vermiculite Avec le temps ces plaques s usent et doivent tre remplac es Cela est galement le cas de Vinverseur de fum es II peut arriver que l une des plaques Skamol se fende apr s avoir t heurt e trop violemment par un morceau de bois Cela n a pas d incidence sur la combustion ce qui n est pas le cas de l inverseur de fum es Lorsque les plaques Skamol sont si us es qu elles ne sont plus enti res il est temps de les remplacer C est galement le cas lorsque les
33. itung Bei Aufstellung Anschluss Ihres Kaminofens sind Gesetze und Bestimmungen einzuhalten die in den rtlichen Bauvorschriften nachzulesen sind Diese besagen dass bei geschlossenen Feuerstellen brennbare Fu b den bis mindestens 30 cm vor der Feuerungs ffnung und mindestens 15 cm zu jeder Seite abgedeckt sein m ssen Die sch tzende Unterlage muss aus nicht brennbarem Material wie z B Stahl oder Glasplatten Klinkern oder Kunstschieferplatten bestehen Einbau des Einsatzes Zwischen brennbaren Fu b den und der Ofenunterkante muss der Abstand mindestens 450 mm betragen Der Einsatz darf nur in eine Wand aus nicht brennbaren Materialien eingebaut werden Die ffnung f r den Einsatz muss mindestens 60 x 40 x 36 H B T gro sein Der Fu boden muss dort wo der Kaminofen stehen soll ausreichend tragf hig sein Der Abstand zu brennbaren Materialien gem EN 13240 geht aus dem Schild auf der Ofenr ckseite hervor abstand hinten cm abstand seitlich zur abstand zu M beln vorn cm r ahmenkante cm Wf 35 20 cm 20 cm 80 cm Bei nicht brennbaren W nden gibt es keine Vorschriften f r den Abstand jedoch empfehlen wir wegen der Reinigung mindestens 10 cm hinter dem Ofen frei zu lassen Weil Verbrennung Luft erfordert ist fur eine ausreichende nicht blockierbare Frischluftzufuhr in den Raum zu sorgen wo der Kaminofen steht Dabei kann es sich um ein offenes ausreichend dimensioniertes Bel ftungsventil
34. l Les arriv es d air doivent tre plac es de mani re ne pas tre bloqu es II peut s agir d un clapet celui ci doit rester ouvert et avoir une capacit suffisante lorsque le po le est allum ou un syst me d air frais raccord au po le Tous les po les de Westfire sont quip s d un inverseur de fum es qui assure un transport des fum es suffisamment long r aCCOr d aVeC La CHeMinEe Le conduit de chemin e utilis doit toujours avoir un diam tre d au moins 15 cm correspondant une ouverture de 175 cm La chemin e doit tre suffisamment longue pour que le tirage se fasse correctement et que la fum e ne g ne pas l entourage en outre la chemin e doit tre quip e d un volet de nettoyage facilement accessible Les mod les WF35satisfont la norme europ enne EN 13240 La puissance thermique nominale est de 4 3 kw Le WF35 a un poids l essai de 110 kg Tirage minimum le po le a t test avec un tirage de 12 Pa Le tirage max est de 25 Pa Le d bit des gaz de combustion est de 4 0 g sec La temp rature des gaz de combustion est mesur e 244 Les mod les WF35 ont la fois des sorties au dessus et l arri re Les chemin es doivent tre quip es d une trappe de r gulation plac e dans le conduit de fum e de mani re r guler le tirage de la chemin e les jours de grand vent La trappe ne doit pas se fermer compl tement mais doit avoir une surface libre d au moins 20 cm s
35. lossen sind Da mit Gas betriebene Heizquellen einen eigenen Schornstein ben tigen d rfen hier keine anderen Heizquellen angeschlossen werden Bedienungsanleitung Da der hitzebest ndige Lack beim ersten Anheizen des Kaminofens aush rtet k nnen sich Ger che und Rauch bilden Aus diesem Grund ist f r gute Bel ftung zu sorgen Bei den ersten Befeuerungen sollte die Ofent r etwas offen stehen und erst nach dem Erkalten des Ofens geschlossen werden damit die Dichtungsschnur nicht festklebt und sich anschlie end abl st Nach dem Aush rten des hitzebest ndigen Lacks muss die Ofent r geschlossen bleiben um ein Entweichen des Rauchgases zu vermeiden Sie darf also nur zum Anheizen Einf llen von Brennholz und Entfernen von Verbrennungsresten ge ffnet werden Beim Anheizen wird das Zuluftsystem durch Herausziehen der Regulierstange und ffnen des Lufteinlasses an der linken Seite ge ffnet Zum Entz nden eignen sich Kaminanz nder gut w hrend Brennspiritus Benzin oder andere feuergef hrlichen Fl ssigkeiten unter keinen Umst nden verwendet werden d rfen Legen Sie einige kleinere Holzst cke ber Kreuz auf die Kaminanz nder Wenn alles gut brennt werden 2 weitere Holzst cke von ca 30 cm L nge Gewicht ca 1 2 kg aufgelegt Nach ca 5 Minuten wird der Lufteinlass f r die Anz ndephase geschlossen und die Regulierstange in der Mitte zu etwa 50 eingeschoben Nach jeweils 1 Stunde ist bei Nennw rmeleistung Brennholz nach
36. ment and mortar to dry out a small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely into the atmosphere Do not run at full output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and notify them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use a fireguard to BS 6539 in the presence of children aged and or infirm persons Operation amp Maintenance Of Your appliance Congratulations on your purchase of your new Uniq 35 new multi fuel stove from Westfire ApS The Westfire uniq 35 is constructed in steel with a vermiculite insulated chamber Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance Warning CO alarm Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Use a fireguard in the presence of children
37. n place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used These chimneys must be fitted in accordance with the manufacturers instructions and Building Regulations Asingle wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 125 mm and its dimension should be not less than the size of the outlet socket of the stove Any bend in the chimney or connecting fluepipe should not exceed 45 90 bends should not be used If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 of the total cross sectional area of the flue or fluepipe Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue pipe WF 35 dimensions uniq 35
38. onditions You need to become familiar with your stove in order to be able to regulate the air controls correctly as outside factors such as the quality and height of your chimney the quality of your fuel and the external weather conditions can alter the stoves operational settings and performance Very damp weather can affect the draw of the stove and therefor more secondary air may be needed to adjust Very still cold clear days induce more draught and the setting for secondary air may be less than nominal settings Such accommodations will become normal once you are familiar with your stove It is easy to see whether the stove is functioning correctly incomplete combustion will be shown by 1 The inside of the fire chamber firebricks having a black dusty build up 2 A build up of hard shiny soot on the inside of the glass 3 Smoking chimney To prevent sooting of the chamber and glass introduce more secondary air also check that your wood is dry It is important to check the draft conditions before lighting your stove This may be done for instance by crumpling a piece of newspaper placing it in the combustion chamber and lighting it The draft conditions are good if the smoke is drawn away through the chimney Door operation When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat The handle pulls out away from the door When shutting the door push the door closed
39. plaques sont fendues plusieurs endroits En cas de surchauffe du po le la trappe d a ration et la porte doivent tre ferm es en Cas de dYsfOnCtiOnneMent Lorsque la vitre se recouvre de suie cela signifie probablement que le bois est humide ou que le foyer ne re oit pas suffisamment d air secondaire Si le bois br le trop vite cela peut tre d au fait que la chemin e tire trop fortement ou qu il y a une fuite dans la porte Lorsque le po le ne chauffe pas suffisamment il se peut que le bois de chauffe utilis soit humide Les probl mes de fum e ou d odeur peuvent tre dus un mauvais tirage de la chemin e V rifiez que le conduit de fum e et la chemin e ne sont pas obstru s et v rifiez la hauteur du conduit de chemin e par rapport aux conditions ext rieures La pr sence de suie dans le conduit de chemin e peut s expliquer par l utilisation d un bois humide ou par un manque d air secondaire lors de la combustion gar antie Votre nouveau po le est garanti cinq ans contre tout d faut de fabrication Votre facture sert documenter la date de l achat La garantie ne couvre pas les d g ts survenus suite une erreur de manipulation notamment la surchauffe un raccord d fectueux ou des dommages survenus pour des causes physiques externes La garantie ne couvre pas les dommages sur des pi ces qui peuvent tre chang es ni les frais de transport suite des r parations sous garantie ni le montage d montag
40. r and leave the primary and secondary air controls open until fire is re established with flames Close primary air control and slide secondary air control to the operational position 50 open Burning Wood in a smoke Control area You must purchase a smoke control version of the Westfire Uniq 35 stove which is modified slightly to comply with regulations Uniq 35 variants listed below are exempt when burning wood logs Code W03503 00 00 00 00 Uniq 35 SE freestanding W03504 00 00 00 00 Uniq 35 SE Pedestal W03506 00 00 00 00 Uniq 35 SE inset with 3 sided frame W03508 00 00 00 00 Uniq 35 SE inset with 4 sided frame Any change to this modification will invalidate the stoves compliance for smoke control areas The Clean air act 1993 and smoke Control areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland an
41. rvlakken warm worden en u moet de benodigde voorzichtigheid in acht nemen Bij de bediening van de klep en de handgreep dient u handschoenen te gebruiken in geval van schoorsteenbrand sluit de luchtklep en de deur bel daarna 112 of de plaatselijke brandweer BasisinsteLLing Van de kLePPen tijdens de Wer king secundaire lucht wf 35 50 open U moet zelf ervaring opdoen met de instelling van secundaire lucht omdat bijvoorbeeld de kwaliteit en de hoogte van de schoorsteen de brandstofkwaliteit en de weersomstandigheden een grote rol spelen maar u kunt zien of de verbranding goed verloopt Als uw kachel aan de binnenkant een harde glanzende roetlaag krijgt is dit een teken van een onvolledige verbranding In dat geval moet er meer secundaire lucht worden toegevoegd Het is belangrijk om v r het stoken de afvoersituatie te controleren U kunt dit bijvoorbeeld doen door een stuk krantenpapier in elkaar te frommelen dit in de verbrandingskamer te leggen en aan te steken Als de rook mooi door de schoorsteen naar buiten gaat is de afvoersituatie in orde nL Br andstof Gebruik nooit giftig hout zoals spaanplaat geverfd of geimpregneerd hout Gebruik altijd droog hout De mate van droogte van het hout speelt een buitengewoon grote rol aangezien te nat hout de stookkosten verhoogt en er ook roetvorming kan ontstaan Pas gehakt hout bevat 60 70 water waardoor dit volkomen ongeschikt is om mee te stoken U dient ervan
42. t Pas wanneer de skamolplaten zo versleten zijn dat ze niet meer heel zijn moet u deze vervangen Dit moet ook als er meerdere scheuren in de skamolplaten zitten Bij oververhitting van de houtkachel moeten de luchtklep en de deur gesloten zijn stOr ingen Als het glas vol roet komt te zitten is dit hoogstwaarschijnlijk het gevolg van nat hout of het vuur krijgt te weinig secundaire lucht Als het hout te snel brandt kan dit komen doordat de schoorsteen te hard trekt of doordat de deur niet goed genoeg sluit Als de kachel te weinig warmte geeft kan stoken met nat hout de oorzaak zijn Rook of stankoverlast kan worden veroorzaakt doordat de schoorsteen niet goed genoeg trekt Controleer of het rookkanaal de schoorsteen verstopt is en controleer ook de hoogte van de schoorsteen ten opzichte van de omgeving Roetvorming in de schoorsteen kan komen door het gebruik van nat hout of doordat er te weinig secundaire lucht bij de verbranding komt gar antie Op uw nieuwe kachel wordt een garantie van 5 jaar op fabricagefouten verleend uw aankoopfactuur geldt als documentatie voor de aankoopdatum de garantie is niet van toepassing op schade als gevolg van een verkeerde bediening bijvoorbeeld oververhitting een verkeerde aansluiting of schade die is ontstaan als gevolg van invloed van buitenaf van fysieke aard De garantie dekt geen schade aan vervangbare onderdelen transportkosten in verband met garantiereparaties of montage demontage
43. ter 125mm In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught so as to clear the products of combustion and prevent smoke problems into the room flue gas flow rate wood coal test flue gas temperature wood coal pascals of pressure uniq 35 4 0 4 7g sec 244 240c 12 NOTE chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in BS 5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 160 mm x 160 mm Remedial action should be taken if required seeking expert advice If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted i
44. ters and push door to closed position and close handle to 1st position this will allow a small gap in the door for more air to be supplied to stove during ignition period 4 When the flames are established and the fire is burning brightly load 1 1 kg of smokeless coal and close door latch to position 2 fully closed Once the fire is burning maintain the secondary air control 100 5 Nowthe fully established fire bed is burning brightly Maintain primary air control at 100 this is the operational setting For the stove to burn cleanly and efficiently primary air is needed do not be tempted to shut the fire down too early as this may cause smoke At nominal heat output expect to refuel your stove once every two hours When lit the stove will get very hot and due care must therefore be exercised Please use a glove and operating tool supplied when operating air controls and riddler Re fuelling smokeless fuel To re fuel your stove Only refuel your stove when flames have died down and you have glowing embers Before refuelling riddle your stove with riddler open secondary air control fully open primary air control fully Open door and re load 1 1 kg of smokeless coal Close the door and leave the primary and secondary air controls open until fire is re established Maintain secondary air control at 100 and maintain primary air control to it operational position 100 open Operational Position of air controls during operation and in adverse c
45. uit te gaan dat pas gehakt hout twee jaar lang onder een halfopen dak moet worden opgeslagen om door de wind te worden gedroogd voordat het voor stoken geschikt is Onder HOud De as moet regelmatig worden verwijderd U mag de kachel alleen schoonmaken als hij koud is Maak de buitenkant van de kachel schoon met een droge doek E n keer per jaar moet de binnenkant van de kachel worden gereinigd door as en eventueel roet en teerresten uit de verbrandingskamer te verwijderen U dient de rookkeerplaat te verwijderen omdat achter op de plaat vuil en roet zal ontstaan De pakkingen in de deur zullen na langdurig gebruik slijten en moeten worden gecontroleerd U dient de haard het rookgasverbindingsstuk en de schoorsteen regelmatig na te laten kijken door een deskundige Als u de kachel gedurende langere tijd niet gebruikt moet de schoorsteen op blokkades worden gecontroleerd voordat u de kachel weer aan kunt steken Op kritieke plaatsen kan de lak slijten als gevolg van oververhitting Net als andere lakschade kunt u dit herstellen met een speciale Senothermlak in een spuitbus die in alle kachelzaken te koop is De verbrandingskamer is voorzien van skamolplaten Deze platen zullen na verloop van tijd slijten en moeten dan vervangen worden Hetzelfde geldt voor de rookkeerplaat Als u een stuk hout te hard in de kachel gooit kan dit tot gevolg hebben dat een skamolplaat scheurt Voor de verbranding maakt dit niets uit geldt niet voor de rookkeerplaa
46. ulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS EB 8303 BS EN 15287 design installation and commissioning of chimneys as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J Health and safety Precautions Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment CO alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturers instructions Provision of an alarm must not be considered a substitute for
47. ur la surface d ouverture totale du conduit Il est galement possible d avoir d autres types de limitateurs de tirage par exemple en laissant entrer l air dans la chemin e sans passer par le po le fr Les mod les WF35 peuvent tre raccord s au conduit de chemin e m me lorsque d autres systemes y sont aussi raccord s Les systemes au gaz doivent toujours avoir leur propre conduit et aucun autre systeme ne doit s y raccorder COnseils d utilisation La premi re fois que vous faites du feu dans votre po le le rev tement r fractaire se solidifie et provoque un d gagement d odeur et de fum e Assurez vous alors que la pi ce est bien a r e Vous devez galement garder la porte l g rement ouverte les deux premi res fois o vous allumez votre po le lorsque celui ci est froid pour viter que la corde d tanch it ne colle au po le et ne se d tache Une fois que le rev tement r fractaire est solidifi la porte doit rester ferm e sauf au moment o vous allumez le po le lorsque vous rajoutez du combustible ou que vous enlevez les cendres pour emp cher que les gaz de combustion ne s chappent La meilleure fa on d allumer le po le est d utiliser des briquettes d allumage N utilisez jamais d alcool d essence ou d autres liquides inflammables pour allumer votre po le Placez des petites morceaux de bois en travers au dessous des briquettes d allumage Avant d allumer votre po le vous devez ouvrir le syst me d
48. validate the guarantee West fire recommend the use Of a flue thermostat to Check Your stove is not Over Heating Place flue thermostat directly above Collar Of stove and refer to temperature gauge in this Manual Overnight burning Westfire UNIQ 35 is designed to burn wood and quality smokeless fuels Wood burns more efficiently and cleanly if is burnt hotter and reloaded regularly Running you stove with combustion air closed is inefficient and bad for the environment Westfire do not recommend that their stoves are burnt overnight for this reason Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use The Westfire Uniq 35 has 1 Heat resistant glove 2 Adjustment tool 3 Instruction manual Maintenance regular maintenance Maintenance is an important factor in maintaining the efficient operation of your stove Please carry out the following actions regularly 1 Remove ash regularly do not allow ash to build up and flow over ash pan This can interfere with air controls Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours Ash must be stored in a non combustible container and must not be mixed with other combustible waste 2 To operate riddling grate push and pull riddling arm on base right of stove using tool provided with the stove 3 Check vermiculite panels these panels can crack this will not affect per
49. year guarantee against material faults and other manufacturing defects in line with the following warranty terms Your receipt documents is the date of purchase The warranty will only apply if we have received from you the duly completed registration card within 2 weeks of purchase Your stove must have been purchased from an authorised Westfire Stoves dealer whose name must be shown on the registration card Your stove must have been installed and serviced within 12 months of installation by a HETAS or equivalent registered engineer This warranty covers replacement or repair of the parts found to be defective but does not cover the labour or carriage charges Westfire Stoves reserve the right to inspect any component prior to replacement Westfire stoves reserve the right to refuse to provide replacement parts in the event that the registration card has not been completed and returned Please note that this is not transferable and is extended only to and is solely for the benefit of the original purchaser of the stove and will therefore only apply when the dated sales receipt as proof of purchase is produced to Westfire Stoves What is not Covered The warranty does not cover 1 Consumable service parts being repair or replacement of parts which are subject to normal wear and tear during the warranty period or parts that require replacement in connection with normal maintenance Such parts include but are not limited to baffles fire bars
50. zulegen Wird eine langsamere Verbrennung geringere W rmeleistung gew nscht legt man einfach weniger Brennholz auf und schiebt die Regulierstange ein mehr als 50 So verl ngert sich die Zeit bis zum n chsten Nachlegen Das Modell WF 35 das h ufiges Nachlegen erfordert ist nicht f r Dauerbetrieb rund um die Uhr ausgelegt Es ist mit einem Regler f r Sekund rluft ausgestattet mit dem sich die Zufuhr von Sauerstoff bei kontinuierlicher Verbrennung einstellen l sst Da alle Teile des Kaminofens bei Betrieb hei werden muss man entsprechend umsicht walten lassen Regulierklappe und Griff d rfen nur mit Handschuhen ber hrt werden Verhalten bei einem schornsteinbrand Luftklappe und T r schlie en dann sofort die Notruf Nr 112 oder die rtliche Feuerwehr anrufen grundeinstelLung der r eguLier kLaPPen Bei Betr ieB sekund rluft Wf 35 Zu 50 ge ffnet Bez glich der Einstellung der Sekund rluft muss man eigene Erfahrungen sammeln da Schornsteinbauweise und h he ebenso eine Rolle spielen wie Qualit t des Brennmaterials Witterungsbedingungen usw Man kann sich aber durch Augenschein berzeugen ob die Verbrennung korrekt erfolgt Bildet sich im Kaminofen ein harter gl nzender Ru belag weist das auf eine unvollst ndige Verbrennung hin In diesem Fall muss mehr Sekund rluft zugef hrt werden Vor dem Anz nden sind die Zugverh ltnisse zu berpr fen Dies kann mithilfe eines zusammengekn llt