Installation manual Solace - Axial fan
Contents
1. Installation manual Solace Axial fan TP200 BA Basic TP200 RT with Timer TP200 HT with Humidistat Timer Introduction solace fig 1 is an axial fan designed to ensure a air extraction in small medium sized rooms such as bathrooms toilets and kitchens Suitable for air discharge directly to the outside or in the presence of short ducted system Wall ceiling or window installation fig 2 Read this manual carefully before using the product and keep it in a safe place for reference This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet TECHNICAL SPECIFICATIONS e Material High quality impact and UV resistant ABS colour RAL 9010 e Design front cover removable for cleaning without the use of tools e Rear reinforcement ring to prevent spigot deformation during installation e High efficiency aerodynamic fan with winglet blades to optimise quietness and efficiency e Single phase EC Brushless motor with integral thermal protection e Motor mounted on high quality ball bearings e The fan is double insulated no earth connection is required e Trickle speed selectable during installation 6 8 13 I s or off e Option to boost from trickle or from off through L
2. EN 5501 4 1 2006 A1 2009 EN 5501 4 2 1997 A1 2001 A2 2008 1S1 2007 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 INSTALLATION Fig 2 perimetrical exhausting wall ceiling accessory on demand window kit on demand direct exhausting MOUNTING AND ELECTRICAL WIRING Solace 099 mm SURFACE CABLE HO3VV F HOSVV F 3X 0 5 1 5 mm 4X0 5 1 mm RECESSED CABLE ENTRY HO3VV F HOSVV F 3X 0 5 1 5 mm 4X 0 5 1 mm Solace BA through wat OFF IN wW CLICK i p u HT H ml I i aren tra 3 al Pr pl y Information on disposal of units at the end of life This product complies with EU Directive 2002 96 EC The symbol of the crossed out dustbin indicates that this product must be collected separately from other waste at the end of its life The user must therefore dispose of the product in question at suitable electronic and electro technical waste disposal collection centres or else send the product back to the retailer when purchasing a new equivalent type device Separate collection of decommissioned equipment for recycling treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment Improper disposal of the product by the user may result in administrative sanctions as provided by law gt
3. The electrical system to which the device is connected must comply with regulations e Before connecting the product to the power supply or the power outlet ensure that the data plate voltage and frequency correspond to those of the electrical mains the electrical power supply socket is adequate for maximum device power If not contact a qualified technician e The device should not be used as an activator for water heaters stoves etc nor should it discharge into hot air fume vent ducts deriving from any type of combustion unit It must expel air outside via its own special duct e Operating temperature 0 C up to 50 C e The device is designed to extract clean air only e g without grease soot chemical or corrosive agents or flammable or explosive mixtures e Do not leave the device exposed to atmospheric agents rain sun snow etc e Do not immerse the device or its parts in water or other liquids e Turn off the main switch whenever a malfunction is detected or when cleaning e For installation an omnipolar switch should be incorporated in the fixed wiring in accordance with the wiring regulations to provide a full disconnection under overvoltage category Ill conditions contact opening distance equal to or greater than 3mm e f the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard e Do not obstruct the fan or exhaust grille t
4. Titon International House Peartree Road Stanway Colchester Essex CO3 OJL Tel 44 0 1206 814879 Fax 44 0 1206 543126 Email ventsales titon co uk Web www titon com CFI00020 0415
5. S connection e Installation type selection available through wall or ducted e PX4 degree of protection e Max consumption of fan is approximately 50mA e Power supply 220V to 240V 50Hz Model Airflow Static pressure Titon Fig 1 Sound pressure Pa max W max dB A 3m 27 2 5 26 23 13 11 Solace 83 47 29 21 PRECAUTIONS FOR INSTALLATION USE AND MAINTENANCE 23 1 13 8 6 e The device should not be used for applications other than those specified in this manual e After removing the product from its packaging verify its condition In case of doubt contact a qualified technician Do not leave packaging within the reach of small children or people with disabilities e Do not touch the appliance with wet or damp hands feet e The device is not intended for use by persons including children with reduced physical sensory or mental capacities or those with a lack of experience and knowledge unless they have been given supervision or instruction concerning use of the device from a person responsible for their safety Children should be supervised to ensure that they do not play with the device e Do not use the product in the presence of flammable vapours such as alcohol insecticides gasoline etc e f any abnormalities in operation are detected disconnect the device from the mains supply and contact a qualified technician immediately Use original spare parts only for repairs e
6. o ensure optimum air passage e Ensure adequate air return into the room in compliance with existing regulations in order to ensure proper device operation e If the environment in which the product is installed also houses a fuel operating device water heater methane stove etc that is not a sealed chamber type it is essential to ensure adequate air intake to ensure good combustion and proper equipment operation e Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger in compliance with the current safety regulations e Ceiling installation In order to guarantee the IPX4 degree of protection against moisture in case of ceiling installation use the appropriate ceiling mount kit which is not included Use only the rear entry hole for supply cables If there is a possibility of condensation along the air discharge duct provide a drainage system to prevent condensation from discharging into the environment through the fan Attention do not mount the product on the ceiling without this kit e Window installation In case of window installation it is necessary to use the appropriate window kit which is not included Attention do not mount the product on the window without this kit BASIC The fan runs continuously at selected trickle speed set by the jumper switch combination see figure 16 and can be boosted with a dedicated ON OFF switch or PIR CO2 sensor or
7. on when the percentage of Relative Humidity exceeds the settable threshold fan speed automatically increases to comfort boost speed which is intermediate between the selected trickle speed and the boost speed When the percentage of Relative Humidity goes below the threshold the fan continues to function at comfort boost speed for a factory set period of time then returns to selected trickle speed Operation with external switch when the external switch is turned on the fan is boosted After the external switch is turned off the fan continues to run at boost speed for a settable period of time then it returns to selected trickle speed or to comfort boost speed in case automatic humidistat operation is on The front cover LED indicates when the external switch is on The over run timer function is activated only if the external switch has been on for at least 60 seconds INSTALLATION TYPE SETTING Installation type can be selected using JUMPER 1 between the following options through wall or ducted See figure 16 TRICKLE SPEED SETTING Trickle speed can be selected using JUMPER 2 and JUMPER 3 between the following options 6 8 13 l s or off See figure 16 STANDARD CONFORMITY 2006 95 EC Low Voltage Directive LVD 2004 108 EC Electromagnetic Compatibility EMC in conformity with the following standards Electrical Safety EN60335 1 2008 EN 60335 2 80 2005 EN 60335 2 80 A2 2009 Electromagnetic Compatibility
8. with a light switch fig 14A Trickle speed can be set to off WITH OVER RUN TIMER The fan is provided with over run timer adjustable from 0 to approx 30 minutes via trimmer fig 15B The fan runs continuously at selected trickle speed set by the jumper switch combination see figure 16 and can be boosted with a dedicated ON OFF switch or PIR CO2 sensor or with a light switch fig 14B Trickle speed can be set to off When the external switch is turned on the fan is boosted After the external switch is turned off the fan continues to run at boost speed for a settable period of time then it returns to selected trickle speed The over run timer function is activated only if the external switch has been on for at least 60 seconds WITH HUMIDISTAT TIMER The fan is equipped with a humidity sensor whose threshold is adjustable from 50 to 95 Relative Humidity via dedicated trimmer and with a timer which is adjustable from 0 to approx 30 minutes via dedicated trimmer fig 156 The fan runs continuously at selected trickle speed set by the jumper switch combination see figure 16 increases its speed in case the percentage of Relative Humidity exceeds the settable threshold and can anyway be boosted with a dedicated ON OFF switch or PIR CO2 sensor or with a light switch fig 14C Trickle speed can be set to off To deactivate the humidistat function turn the trimmer HY completely clockwise Automatic humidistat operati