PS-6609 Outdoor Triple Technology Microwave/PIR - Dolphin-3
Contents
1. 5 ws 8m y 4 A 4 7 4h JE f f 7 sa 4 7 2 1m 1 2m4m 7m Area
2. _ e Multi directional mounting bracket PS BK5 A a eS N W Ne Sane 7 Back N N ON SZ sS Fig 2 Back A A SQ AD OYA 8 Screw for Daal INSTALLATION 1 Location Installation locations should be carefully selected to avoid proximity to any of the following Sun shone directly rain dipped reflective surfaces sources of steam oil vapor objects causing temperature changes such as heaters and ovens and infrared light sources Large reflecting objects especially metals within the coverage area can distort the microwave detector s coverage Salt alae eye mount the unit on a firm and stable surface at a height that renders optimum coverage of the protected area 2 Mounting Select the detector installation site based on the required coverage and recommended height of 1 8m to 2 4m The detector comes equipped with the Posonic no dead zone pet immunity lens The unit can be installed directly on the wall using the mounting Knockouts Optional swivel brackets permit greater flexibility when adjusting the coverage area After selecting the detector s location drill holes for the screws as per figure 2 Holes A B C and D are to be used for corner mounts For a corner mount the PCB can be carefully removed by loosening the PCB screw In the case of flat surface installation utilize holes M and N Run the wires through entry holes L and connect them according to the marking on the PCB or FTG 3 For swivel bracket
3. mounting utilizes hole E F G H J and K to fix to the bracket The angle of bracket can be adjusted down 0 30 and left right 0 90 in order to get a good coverage area 3 Wiring 12 V and Connect to a power source within the range of 9 to 16 VDC Take care not to reverse the polarity l N C and C Normal Closed Alarm Output Connect to Fig 3 normally closed burglar protection zones of the Terrminal Block Wiring control panel N O and C Normal Opened Alarm Output Connect to normally opened burglar protection zones of the control panel 12 345 67 89 BG 8SS oo oo Terminal for connection of a EOL resistor Alarm Memory Control this point receives signal from the panel If OV is received the detector will understand that the system is armed If 12V or no voltage is received the detector will understand that the system is disarmed TAMP Tamper Switch output Connect to a normally closed 24 hour tamper zone of the control panel 4 Alarm Memory Using the programmable output of the control panel to generate 12V to the terminal MEM of 6609 upon arming will trigger the alarm memory function of 6609 If the detector is alarmed during armed period the alarm signal will be memorized and the LED will lights for 30 minutes when the panel is disarmed delete 12V C N C NO TAMP 3 i 12V DC uls 5 Coverage and Adjustment At the recommended installation height of 1 8m 5 8 ft to 2 4m 7 8 ft fr
4. the motion first Upon subsequent discovery of the motion by the PIR sensor the yellow and red LED will flash alarm 2 If the yellow or red LEDs do not illuminate during walk test a malfunction has been diagnosed Replace the unit without delay 2 Mode Setting The mode setting DIP Switch is mounted on the detector s PCB board see Fig 1 It controls four functions as demonstrated in Fig 6 and as detailed in Table 2 Table 2 Mode Setting DIP Switch Fig 4 DIP Switch Mode Selector SW 1 ON _ AIl LEDs are enable N SW 2 Jsa OFF Microwave and PIR OFF Detection Mode LED On off PIR Sensitivity ADJUSTMENT AND TEST 1 Setting the PIR Pulse Count If you wish to set the PIR detector for maximum false alarm immunity shift DIP switch 2 SW 2 to OFF In this position two consecutive motion pulses are required to trigger the PIR detection For faster catch performance shift SW 2 to ON In this position only one motion pulse is required to trigger the PIR detection 2 PIR Walk Test A Rotate the MW sensitivity adjust all the way towards minimum turn the adjust anti clockwise B Verify that DIP switch SW 1 is set to ON the red walk test LED is enabled C Mount the front cover in place D Walk into the detector s field of view at the expected far edge of the coverage area The red LED should illuminate for up to 3 seconds each time your motion is detected 3 MW Walk Test A Remove the front co
5. PS 6609 Outdoor Triple Technology Microwave PIR Motion Detector Installation Manual INTRODUCTION The 6609 MW PIR is state of the art microcomputer Fig 1 Exploded controlled triplex technology outdoor intrusion detectors for View industrial commercial and residential security It uses double E PIR and MW technologies when combined in a single 1 Cover detector complement each other to assure the most reliable ae EW detection and immunity to false alarms The superiority of the A a ae 2 Lens 6609 series over other triplex detectors has been achieved by the advent of the True Motion Detection Technology A NN algorithm This advanced motion analysis method provides N SX the 6609 with the ability to distinguish between the true QA NN motion of a human body and any other disturbances which YX NN NK invariably cause false alarms S WAAAY FEATURES 9 DIP Switch eT M a e 4 dimensional all in one motion detector N V P Pa 3 PCB Module Screw Two PIR sensors with opposite direction 40 kg Pet A i it Adjustment mmuni y J 4 Red LED e Auto Background analyse bec 11 l e Selectable PIR detection sensitivity Selectable Microwave Er 5 Anti Tamper ee Switch detection sensitivity e Selectable detection technology combination 12 Yellow LED e Memory latched input alia e Auto temperature compensation Block False alarm prevention of wind immunity and waving i leafs immunity fo
6. eller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold SPECIFICATIONS PIR Sensors Two Low noise dual element pyroelectric sensor PIR Trigger Indication Red LED illuminates for up to 3 seconds Pulse Count Selectable 1 or 2 pulse count 34 beams 110 field of view 12m x 110 Microwave Frequency 10 525 GHz Microwave Range Adjustable from 25 to 100 6 m to 24 m ivivv i rigger indication Alarm Yc low LED illuminates for up to 3 seconds Indication Red and Yellow LEDs flashes for 2 3 seconds Microwave Oscillator DRO stabilized type Normally closed and normal opened 0 1 A resistive 30 VDC 300hms resistor in series with contacts 3 seconds red and yellow LED flash and output relay contacts trigger Surface or corner without brackets from 1 8 m to 2 4m high Waterproof Rating IP65 Operating Temperature 10 C to 50 C Dimensions H x W x D 168 x 95x65 mm Net Weiaht 203a Infrared and Microwave Detection Top View OE ire Microwave 12m 4 fp K Detection Area P AE p j Za l Ji b i i f Microwave y lt d 7 Detection Side view Area 45
7. om the PS 6609 will provide full coverage 1 2m 4 ft to 12m 39 ft without any dead zones Your unit is equipped with automatic temperature compensation which adjusts amplifier gain to maintain coverage levels across a wide range of temperatures Any mounting height should be followed by a walk test of tne protected area Walk testing verifies that the required coverage is in place With the Posonic standard lens there should be no dead zones in tne protected area When walk testing always move across the path of detection not toward the detector 6 Power on After connecting the power source the 6609 starts a 90 seconds warm up period indicated by alternate flashing of both red and green LEDs If the alternate flashing of the LEDs do not stop within 90 seconds a failure has been detected by the self test circuit Then the Green LEDs blink rapidly indicating that the detector is starting the background analysis Once the analysis completed the Green LbDs blink again for 5 seconds The detector is ready to work now INDICATION AND SETTING 1 LED Indications The three LEDs Fig 1 are used to signal various alarm and trouble messages as shown in Table 1 below Table 1 LED Indications Meaning On Off Wis triggered Off On PIR is triggered Alarmed Notes 1 During walk testing normally the first LED to illuminate is the yellow one MW detection depending on which one of the two kinds of sensors MW and PIR discovered
8. tracing the coverage pattern E Remount the cover and fasten it to the base using a screw at the bottom PET IMMUNITY The 6609 has two dual opposite element sensors for of 3 D space detection In addition it combines with the proprietary Pet friendly lens greatly decrease false alarms created by pets In order to generate an alarm an object must cross the beams created by both the lower and upper sensor Due to the small height and volume of a pet they will not generate the required signal value normally recognized as an alarm situation Any PCB adjustments should be followed by a walk test of the protected area Walk testing verifies that the required coverage is in place WARRANTY The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Since the Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the S
9. ver B Verify that the MW sensitivity adjust is set to minimum turn the adjust anti Fig 5 clockwise and DIP switch SW 1 is set to ON the walk test LED is Microwave Sensitiv ity enabled C Start by moving into the coverage area at the far edge The yellow LED should light steadily for up to 3 seconds each time your motion is detected D IT your motion was not detected at the far edge of the coverage area advance the MW adjust slightly toward maximum clockwise and try again until your motion is detected reliably at the far edge The sensitivity can be adjusted between 25 to 100 6 24m Caution The MW detection range must not exceed the far edge of the desired coverage area otherwise it will detect movement from outside the walls of the protected area and causes false alarm E Walk across the coverage area at various ranges and verify that your motion is consistently detected Note If PIR trips interfere with your test disable the PIR by inserting a small piece of cardboard in front of the sensor 4 Alarm Walk Test A Set DIP switches SW 1 to ON all LEDs are enabled B Install the front cover in place C Walk across the detector s field of view in different directions at various distances from the detector and verify ad detection throughout the detector s coverage area the yellow and red LED will flash for 3 seconds D When done remove the cover and set DIP switch SW 1 OFF to prevent unauthorized people from