Home
Operating instructions
Contents
1. lt lt lt lt lt lt lt lt lt lt lt lt lt lt 11 General safety instructions When using your lighting equipment basic safety precautions should always be followed including the following 1 2 10 Read and understand all instructions before using Close supervision is necessary when any lamp is used by or near children Do not leave lamp unattended while in use Care must be taken as burns can occur from touching hot parts Do not operate lamp with damaged cable or if the lamp has been dropped or damaged until it has been examined by a qualified serviceperson Position the cable so that it will not be tripped over pulled or make contact with hot surfaces If an extension cable is necessary a cable with a current rating at least equal to that of the appliance should be used Cables rated for less amperage than the appliance may overheat To reduce the risk of electric shock never open this unit take it to a qualified serviceperson when service or repair work is required Incorrect reassembly can cause electric shock when the equipment is subsequently used The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons Always unplug ballast unit and lamp before cleaning or servicing and when not in use Never jerk cable to pull plug from socket Grasp plug and pull to disc
2. Operating instructions kobold by bron Lumax www bron kobold com Operating instructions kobold Lumax Ballast units EB 2x20 40 EB 4x20 40 Light banks SB 12 22 SB 14 24 Before use Please read all the information contained in these operating instructions carefully They contain important details on the use safety and maintenance of the lighting equipment Keep these operating instructions in a safe place and pass them on to further users if necessary Observe the safety instructions Contents General safety instructions 2 Attention Read before starting UD ccccccceee eee e eee e eee e eee nenne nennen nennen nennen 3 12Starting Up za ae ee e ai di a i d a iad 4 2 Power reg lation ss Y ow 4 3 Installing or replacing tubes lt lt lt lt lt lt lt lt lt lt 4 4 Controls and displays ballast units lt lt lt lt lt lt lt lt lt lt 5 5 Technical data 28185101118 lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt 7 0 Controls ligh D nks Y OO Ik ainka RiN 8 7 Technical data light banks 22000000000000000000000000nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 10 8 Replacement parts and 55 1 5
3. generators Kobold equipment is basically suitable for operation with motor generators provided that the supply voltage remains within the tolerance limits of 200 264V or 95 135V respectively under all load conditions including capacitive load Experience shows that this usually requires electronically stabilized motor generators Controls Light banks Lumax SB12 SB 22 SB 14 SB 24 O DAN o o PF WN gt N o Housing Barn door Cable stub for connecting lamp cable Velcro locking for barn door Velcro fastening for light grid Safety rope for light grid Stand adapter plate with ball joint Safety loop for ceiling installation Eye for wall installation Retaining clips for fluorescent tubes with 26 mm and 38 mm 9 Plug in contacts for fluorescent tubes Fluorescent tube e d ba bd bd b Da Se Da lt lt lt O G 10 r u WI 8 Technical data light banks Lumax SB 12 Article no Dimensions Weight Lamp cable Tubes Photometric Lumax SB 22 Article no Dimensions Weight Lamp cable Tubes Photometric Lumax SB 14 Article no Dimensions Weight Lamp cable Tubes Photo
4. metric Lumax SB 24 Article no Dimensions Weight Lamp cable Tubes Photometric 381 1012 700 x 193 x 87 mm without adapter plate 1 6 kg tubes incl without adapter plate 3 m removable alternatively 26 mm or 38 mm 320 Ix at 2 m 381 1022 1310 x 193 x 87 mm without adapter plate 3 2 kg tubes incl without adapter plate 3 m removable alternatively 26 mm or 38 mm 750 Ix at 2 m 381 1014 700 x 321 x 87 mm without adapter plate 2 7 kg tubes incl without adapter plate 3 m removable alternatively 26 mm or 38 mm 320 Ix at 2 m 381 1024 1310 x 321 x 87 mm without adapter plate 4 3 kg tubes incl without adapter plate 3 m removable alternatively 26 mm or 38 mm 750 Ix at 2 m 11 9 Art Art Art Art Art Art Art Art Art Art Art Art Art Art Art Replacement parts and accessories no no no no no no no no no no no no no no no 742 0719 742 0715 683 1075 683 1135 673 1075 673 1135 033 0117 033 0103 033 0118 033 0104 033 0114 033 0102 033 0116 033 0101 817 0810 Lamp cable 3m for SB 12 and SB 14 Lamp cable 3m for SB 22 and SB 24 Daylight fluorescent tubes 20 W 5800 K with safety sheath for SB 12 and SB14 Daylight fluorescent tubes 40 W 5800 K with safety sheath for SB 22 and SB24 Artificial light fluorescent tubes 20 W 3400 K with safety sheath for SB 12 and SB14 Artificial light fluo
5. onnect Lumax ballast units and light banks are not compatible with products of other manufacturers Lumax light banks or ballast units must only be used with kobold products Attention Read before starting up For safety reasons the ballast units EB 2x20 40 und 2x20 40 may only be operated with an earthed mains AC line plug These appliances are designed for use indoors and out Though they have to be kept dry To reduce the risk of electric shock do not immerse the ballast units and light banks in water or other liquids Before replacing fuses or fluorescent tubes disconnect the ballast unit from power supply The equipment is not suitable for use in explosion hazard areas Starting up Equip the light bank with tubes Connect the kobold lamp cable to the light bank and the ballast unit Screw the mains cable onto the ballast unit Ensure that the cap nuts are fixed tightly Connect the ballast unit to the earthed mains supply The appliances are designed for mains voltages from 200 up to 240 V or from 100 up to 120 V version 120 V Set the switch lever for power selection to the corresponding position SB 12 SB 14 20 W SB 22 SB 24 40 W Tum the dimmer to the right as far as it will go max Switch on the mains switch on off the tubes need a heat up period of a few minutes undimmed i e on full power Power regulation The required light output can be set 100 30 adjustment range wi
6. rescent tubes 40 W 3400 K with safety sheath for SB 22 and SB24 Light grid for SB 12 black Light grid for SB 12 silver Light grid for SB 22 black Light grid for SB 22 silver Light grid for SB 14 black Light grid for SB 14 silver Light grid for SB 24 black Light grid for SB 24 silver Adapter plate with 16 mm socket and mount 12 Ce Bron Elektronik AG CH 4123 Allschwil Schweiz Switzerland 13 Printed in Switzerland 11 03
7. th the power regulator dimmer Please note that the colour temperature can change depending on which type of tubes are used Installing or replacing tubes Never replace a lamp without first disconnecting the light bank from the ballast unit Controls and displays EB 2x20 40 EB 4x20 40 Grip Lamp socket Mains cable socket Mains fuse Mains switch on off with monitoring lamp Power selector SD O SO Dor e Power regulator 5 Technical data ballast units Lumax EB 2x 20 40 Article no Mains voltage Mains frequency Output Nominal capacity Safety class Dimensions Weight Power variation 230 V version 742 0420 200 240 V AC 50 Hz 60 Hz 100 VA 2x20 W 40 W switchable 503x88x62 mm 1 3 kg 100 30 Lumax EB 4x 20 40 Article no Mains voltage Mains frequency Output Nominal capacity Safety class Dimensions Weight Power variation 230 V version 742 0220 200 240 VAC 50 Hz 60 Hz 200 VA 4x20 W 40 W switchable 503x132x62 mm 1 8 kg 100 30 120 V version 742 0310 100 120 V 50 Hz 60 Hz 130 VA 2x20 W 40 W switchable 503x88x62 mm 1 4 kg 100 30 120 V version 742 0120 100 120 V 50 Hz 60 Hz 260 VA 4x20 W 40 W switchable 503x132x62 mm 1 9 kg 100 30 6 Operation of kobold equipment with motor