Home
Deliverance 60H
Contents
1. DELIVERANCE E DELIVERANCE VACUUM TUBE GUITAR AMPLIFIER MODEL D60H OWNERS MANUAL WELCOME TO THE FAMILY Congratulations and thank you for choosing the Deliverance Sixty Guitar Amplifier At Fryette Amplification we know you are constantly searching for new sounds and new ways to improve your existing sound We understand the constantly evolving nature of artistic creativity and the search for the perfect sound to complement your ever widening musical vision Providing the tools to help you to create your own sonic signature is our primary mission As with all Fryette amplifiers the Deliverance Sixty amplifier beautifully accentuates the inherent qualities of any instrument lt breathes and dynamically responds to your playing technique exactly the way a great guitar amp should And as stomp boxes have gained more widespread appeal you will find Deliverance amps to be pedal friendly and ultra responsive to the many colors pedal effects produce The Deliverance preamp section has a broad dynamic range which accounts for its extra touch sensitivity and excellent guitar volume response In addition clean and overdriven voicings can easily be dialed up on the Deliverance Sixty using the unique GAIN GAIN Il structure tone controls presence and depth From there just a little tweaking on your guitar volume and tone controls will yield a surprising amount of control The D60H power amp section is designed for big round tone
2. or for any delay in the performance of this warranty due to causes beyond our control Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of consequential damages so the above limitations on implied warranty and consequential damages may not apply to you This warranty gives you specific legal rights You may have other rights that vary from state to state STEVEN FRYETTE DESIGN INC 1201 S FLOWER STREET BURBANK CA 91502 TEL 818 846 4000 FAX 818 846 4040 www sfdamp com Copyright 2009 Steven Fryette Design Inc
3. We certify that all of our products exceptions see listed below are compliant with the European Union Directive 2002 95 EC for the Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment ROHS No Lead Pb Cadmium Cd Mercury Hg Hexavalent Chromium Cr 6 PBB or PBDE is intentionally added to these devices Any trace impurities of these substances contained in the parts are below the RoHS specified threshold levels All information provided in this Certificate of Compliance is accurate to the best of our knowledge as of the date this Certification was issued Certificate of Compliance Registration Evaluation Authorization and Restriction of chemicals REACh We declare that all of our products are compliant with European Union Directive EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemicals in the REACh regulation All information provided in this Certificate of Compliance is accurate to the best of our knowledge as of the date this Certification was issued Declaration of Conformity EMC and Low Voltage Directive CE Product Name Deliverance Sixty Amplifier Model Number D 60 H This is to certify that the product listed above complies with the following European Union Council Directives and Standards relating to electromagnetic compatibility EMC Directive 89 336 EEC
4. and the low voltage Directive 73 23 EEC This declaration of conformity of the European Communities is the result of an examination carried out by Electromagnetic Engineering Services Inc in accordance with European Standards EN 50081 1 EN 50082 1 and EN 60065 for low voltage as laid down in Article 10 of the EMC Directive Steven Fryette Design Inc 1201 South Flower Street Burbank CA 91502 USA FRYETTE AMPLIFICATION LIMITED WARRANTY Subject to the obligations and exclusions found below this product is warranted by Steven Fryette Design Inc herein SFD against manufacturing defects in materials and workmanship for the period of Five 5 Years from the date of purchase with the exception of the tubes fuses and speakers where applicable which carry a 90 day warranty The warranty period commences on the date of purchase by the original user Performance under this warranty must be obtained at one of the following an SFD Authorized Service Station by returning the unit to the SFD factory with prior written authorization or in countries outside of the United States by a representative SFD distributor Obligations 1 This warranty will be honored only on the presentation of the original proof of purchase 2 Transportation of the product to and from an authorized SFD service outlet is the responsibility of the user Units sent directly to the SFD factory for warranty repairs must be authorized by SFD and shipped prepai
5. FUNCTIONS FRONT PANEL LEFT TO RIGHT GAIN GATE 99 gg IEEE Ty PREAMP GAIN VOLUME EQUALIZATION POWER AMP 1 GUITAR INPUT Plug in your guitar or stompbox here PREAMP GAIN VOLUME SECTION 2 GAIN VOICING Sets the amount of overdrive in the second gain stage This first gain control also serves as a tone shaping control counter clockwise for crisp and articulate clockwise for thick and saturated 3 GAIN II OVERDRIVE Full frequency gain boost or cut Sets the amount of overdrive in the third gain stage Works in conjunction with Gain to dial in the perfect overdrive sustain amount for your guitar and pick up combination 4 MORE LESS This switch selects three stages or four stages of tube preamp gain depending on the amount of overdrive required LESS 3 stages MORE 4 stages When using stomp boxes or active pick ups four stages of gain are often unnecessary and generate undesirable levels of background noise so the ability to defeat the additional stage is a real plus 5 MASTER VOLUME Power amp volume loudness control EQUALIZATION SECTION Passive Interactive tone controls 6 TREBLE Passive High frequency equalization 7 MIDDLE Passive Mid frequency equalization 8 BASS Passive low frequency equalization POWER AMP RESPONSE CONTROL SECTION 9 PRESENCE High frequency variable feedback in power amp section 10 DEPTH Variabl
6. and dynamic response at low to medium guitar volumes and a rapid but smooth transition into saturation turning rich and thick at full guitar volume This combination of preamp voicing and power amp response enhances the unique character of any guitar and pick up type Specially designed precision wound power and output transformers produce optimum performance reliability and stability delivering excellent power tube response and just the right amount of natural output transformer saturation and compression Getting familiar with the Deliverance amplifier is easy so don t be terribly surprised when you find yourself up and running in no time First hand experience and real world application will yield the ultimate satisfaction of finding your own path of comprehension and self expression IT ALL STARTS HERE The Input Sensitivity of an amplifier commonly referred to as GAIN determines how much overdrive and sustain your guitar will produce Tonal balance which we refer to as VOICING determines how the amp will respond to your playing style and sound with a particular guitar Like all amplifiers the D60 has tone and gain controls but unlike any other amplifier the D60 gives you total control over VOICING and GAIN This GAIN GAIN II MASTER VOLUME configuration is the key to dialing in the Deliverance sound and volume to your specific requirements PREAMP GAIN VOLUME Sai Seite frate Dimer Le e L e pei AE AA n le I APA A AA
7. A A GAIN increases the gain amount as you rotate the knob clockwise As the gain increases the tonal balance is shifted from a treble and upper mid emphasis which produces an up front sparkling tone to a lower mid and bass emphasis which produces a thick meaty tone GAIN Il increases the gain amount as you rotate the knob clockwise but with no alteration of the tonal balance Different combinations of GAIN and GAIN Il settings will have a dramatic effect on the response of the amplifier and the personality of your instrument lt is easy to get familiar with the action of these controls and you ll be amazed with your ability to make any guitar sound mellow fat soulful or aggressive The MORE LESS switch activates or defeats a tube gain stage The interesting and often overlooked benefit of this switch is that you can use it in conjunction with the gain controls to tailor your tone as well as distortion amount For example set GAIN I GAIN II MORE LESS and MASTER VOLUME as shown in the photo above and play for a few minutes Now set these controls as shown in the photo below Notice that the overall amount of overdrive is approximately the same as it was but the tonal balance has shifted markedly from full and warm to crisp and spanking As you will see by experimenting with combinations of settings you can cover an awful lot of tonal territory before you even begin to start thinking about tone control settings DELIVERANCE D60H
8. D LOCATION CHART Preamp tube locations are indicated by tube type on the rear panel of the chassis Tube types are factory selected for superior performance consistent tone quality and reliability While substituting other brands may not cause damage to the amplifier this may affect amplifier performance in unpredictable ways For best performance replace only with factory recommended tubes Warning Substituting other tube types is not recommended Each 12AX7 has two sections functions Section A is shown first Section B is second Factory recommended tubes are listed under each location Numbering sequence is right to left looking at back of amp starting with the row closest to front panel of amp V1 shielded tube 12AX7A Tung Sol 12AX7WB Sovtek 12AX7 China Selected V2 shielded tube 12AX7A 7025 China V3 shielded tube 12AX7A 7025 China V4 12AX7A 7025 China V5 V6 KT88 Sovtek KT88 EH KT88 Svetlana 6550 Sovtek 6550 Svetlana Input Gain Stage 1 Parallel Triodes Use in place of Tung Sol for smoother top end and less upper mids Use in place of WB if more gain is required Gain Stage 2 Gain Stage 4 Active only when MORE LESS switch is set to MORE Gain Stage 3 Tone Control Driver Phase Inverter Power Tubes MUST USE ONLY KT88 or 6550 NOT INTERCHANGEABLE WITH ANY OTHER TUBE TYPES FRYETTE ANMNPLIFICATION Certificate of Compliance Restriction of the use of Hazardous Substances RoHS
9. d Exclusions 1 This warranty shall not cover adjustment of consumer operated controls as explained in the appropriate instruction manual or products that have been altered or have missing or defaced serial numbers 2 This warranty shall not apply to the appearance of accessory items including but not limited to cabinets cabinet parts or knobs 3 This warranty does not apply to uncrating setup installation or the removal and reinstallation of products for repair 4 This warranty shall not apply to repair or replacements necessitated by any cause beyond the control of SFD including but not limited to any malfunction defects or failure caused by or resulting from unauthorized service or parts damaged or broken tubes incorrect line voltage improper maintenance modification or repair by the user abuse misuse neglect accident fire flood or other Acts of God 5 Responsibility for the repair of any SFD product sold outside of U S boundaries is borne by the SFD representative in that particular country or territory Also the warranty term and conditions may be different from those stated above Please contact the SFD distributor or dealer in your country for more information The foregoing is in lieu of all other expressed warranties and SFD does not authorize any party to assume for it any other obligation or liability In no event shall SFD be liable for special or consequential damages arising from the use of this product
10. e damping Controls low frequency interaction between amplifier and speakers AC POWER STANDBY 11 STANDBY Turns on high voltage to output section 12 MAINS Switches main AC power on or off DELIVERANCE D60H FUNCTIONS REAR PANEL LEFT TO RIGHT HANOOURT DY ROCKERS IN THE USA STEVEN FAYETTE DESSON INC BURBANK CALIFORNIA 91502 12407 AT Wit 1 GROUND SWITCH Select position which yields quietest operation With a properly wired AC outlet and factory supplied AC cord this switch will not produce a noticeable difference 2 AC MAINS INPUT Connect to a grounded outlet in accordance with the voltage and frequency specified on the rear panel of your amplifier A Use only the factory supplied cord set or a UL approved equivalent type 3 MAINS FUSE Protects the amplifier from electrical faults Replace only with type and rating specified on the rear panel of your amplifier 4 DC FUSE Protects the power supply and output transformer from electrical faults Replace only with type and rating specified on the rear panel of your amplifier AN Warning Replace only with same fuse type and rating 5 IMPEDANCE SELECT 4 8 or 16 ohms Example Two 8 Ohm cabs 4 Ohms two 16 Ohm cabs 8 Ohms 6 SPEAKER OUTPUT Parallel wired jacks Impedance switch setting should equal total of all cabinet impedances plugged into both jacks Use First jack must be plugged in for output to operate TUBE FUNCTION AN