1. mounting the device on a metal plate it is recommended to replace the antenna directly mounted on the device by an antenna mounted at a remote place and connected with the device by a corresponding connection cable Antenna connection for mini antenna or external antenna passed out 1 Unscrew the four screws to remove the cover 2 Installing the device on a flat surface Display m R al e JEEN ee tr ee ee amt DIP switches for setting zi i w i aa n up the sensor type Sensor Voltage 20 VDC Common ground Input clamps for connection of sensors USB port to connect a PC for device configuration Cable glands for power supply small and sensors large Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device T 49 3375 529649 0 RAMOC VD5 MO8 4 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 2 7 Inserting the GSM SIM card Note The device must be disconnected from energy supply while inserting the GSM SIM card 1 Remove the device cover 2 Remove upper visible circuit board Sensor connection board by ee the four screws carefully and disconnect it from the lower circuit board Main Board by carefully disconnecting the internal flat ribbon cable 3 Open the SIM card holder on the now visible circuit board Main Board b
2. 0 ms o contact laod lt 4mA pulsed Digital Input o for the connection of potential free contacts o contact laod lt 4mA pulsed Other measurement ranges possible on request Clamping range 0 08 2 5 mm Suitable cable diameter of M20 gland 6 12 mm electronically controlled voltage generation for sensors typically 20 V maximum total current of all sensors typically 100 mA Sensor power supply Radio built in GSM modem quad band from Cinterion SIM card required 3V or 1 8V Antenna external dual band antenna with FME connector 0 dB which if required can be replaced by an alternative antenna Power supply U nominal voltage 6 25V DC when using the rechargeable battery backup 16 V DC Clamping range 0 08 2 5 mm 2 Suitable cable diameter of M16 gland 4 8 mm Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device T 49 3375 529649 0 RAMOC VD5 MO8 5 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 7 7 Current In normal operation typically 40 mA consumption in send receive mode briefly up to 0 5 A Manufacturer Innotas Produktions GmbH Friedrich Engels Str 46 D 15745 Wildau Germany Scope of delivery Remote transmission device Standard antenna Pluggable mains adapter Installation and Operating Instructions Configuration
3. 4 Page 4 7 Implementation After connecting the power supply the remote transmission device boots automatically Please monitor the display output during the boot process The Service Button allows choosing between different display representations Basic screen display RAMOC VD5 MO Content GSM online 1 Title line Name of the shown screen display DS Speicher 22 2 GSM GSM GPRS Status of the internet connection to the 7 server 3 DS Speicher Number of not yet transmitted data measured values remained in the device memory Total DS Total number of records received from the transmitters since power on Power supply status Meaning of the red light Us lights when sensors are supplied with energy and analog measurement values are recorded Meaning of the red light Standby RX flickers irregularly if PC is connected Operation Generally after booting the remote transmission device does not requires any further action However the following operator actions are possible while the cover is removed Pressing the Service Button in the device a Short pressing switch the display screen b Press and hold for at least 6s Reset the device Subsequently the case cover has to be mounted while checking the correct fit of the inserted seal Contrast control Service Button Maintenance The remote transmission device is maintenance free If required the display contrast can be adjusted with
4. 5 MO VD5 MO8 VD5 ST2 Control Station Mainwein Lohr z _Accept Center RAMOC Serial number 0896156 Alarm via SMS to phone number Firmware version j Alarm via SMS to phone number f Alarm ieee No Alarm via SMS to phone number f monitor Name Mainwein Lohr Alarm via SMS to phone number f enabled Location 97816 Lohr Am Sommerberg Alarm via SMS to phone number f ppan Data logging period 360 Seconds 60 minutes ae ea TAA s Table Online spand o lo a En Alarm via SMS to phone number As Map Zs 2 T Alarm via SMS to phone number Transmission period o minutes vee by Input Accu charging circuit r SMS content w History Min Max _ Input 1 Input 2 Input 3 Input 4 Supply voltage Accu voltage Chart Visibility for user group iM aM 3M 4M 54 1M 2M 3M 4M 5M 1M 2M 3M 4M 5M 1M 2M 3M 4M sv 1M 2M 3M 4M 5M il 2M 3M 4M 5M Input type kd notused z notused v Analog input bd Analog input X Analog input _y notused v Single station a n Overview Name ad F llstand Druck Versorgung History A C Measurement unit kg bar V vV History 2 D Invert in the device Lid Usertext D Invert in the control center A Create fill level forecast Warning limit Iv O 2 days days 1 days days v v 29000 kg 0 kg J 10000 kg 2 29200 kg J 6000 kg gt 29400 kg 5 0 2 245 Other Settings Help Alarm limit About Us A Sens
5. Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device T 49 3375 529649 0 RAMOC VD5 MO8 5 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 1 7 Device Description The remote transmission device VD5 MO8 is part of the RAMOC product family which is intended for mobile radio based transmission of process data and the remote switching of industrial equipment The VD5 MO8 is used for remote viewing and mobile based remote transmission of up to 8 input states via GPRS The radio transmission of the input states is done periodically as well as upon reaching predetermined limits or on demand Safety notes e Disconnect the unit from power supply during transportation and mounting of the device e Use a damp cloth and washing up liquid to clean the case of the unit Under no circumstances use abrasives or other chemical cleaners e Mount the GSM antenna in a sufficient distance from people animals and electronic equipment e Follow the guidelines for lightning protection while laying out cables for telecommunication equipment and assembling the antenna e The technical data specified for the VD5 MO8 must be observed Mounting For mounting the device the cover has to be removed The device has to be mounted on a flat surface with at least two screws arranged diagonally Note When
6. instructions Configuration software via web site www innotas service de Optional Solar version in a cabinet with rechargeable battery and solar controller accessories Control center software and hardware External antenna GSM SIM card on request
7. ortype 4 20 mA Logout A show also in A Sensor range A Minimum value Questions B A Low warning range 493375 A High warning range A Low alarm range A High alarm range A Low spread 0 254 A High spread 1 255 C Pulse multiplier C Set counter value C Counter period Response to an event Create record vy Create record v Alert message v 10 s 10 E 10 s Seeeeeeeeoeoeeeee eo o Debouncing Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device 49 3375 529649 0 RAMOC VD5 MO8 5 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 6 7 Specifications Type of the device RAMOC VD5 MO8 Plastic polycarbonate degree of protection IP65 Dimensions W x Hx D 90x 115 x 80 mm plus fittings and antenna Typical mounting height with screw antenna and cable 230 mm Wall mounting using screws diameter 4 mm Inputs 8 universal inputs configurable as Analogue Input o Resolution 8 Bit prepared for sensors with 4 20 mA Output input resistance 125 ohms Q 20 mA Output input resistance 125 ohms 0 10V Output input resistance 40 kohms other measurement ranges possible on request Counter Input digital o forthe connection of potential free contacts o puls duration gt 100
8. per 2 Terminal clamps of the power supply Finally reconnect the internal flat ribbon cable of the upper board Sensor connection board to the Main Board and mount the upper board by means of the four screws Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device 49 3375 529649 0 RAMOC VD5 MO8 5 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 3 7 Sensor connection 1 Remove the device cover 2 For each input 2 DIP switches have to be set up according to the below illustration 0 10 V sensor 0 4 20 mA sensor Digital Input Counter Illustration Setup of DIP switches depending on the sensor type 3 Thread the sensor cable through the large cable entry of the case Strip a length of about 5 mm of the cable wires and connect them to the terminal clamps 5 Tighten the large gland Subsequently the case cover has to be mounted while checking the correct fit of the inserted seal Finally the cable glands have to be checked and tightened if necessary Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device 49 3375 529649 0 RAMOC VD5 MO8 3 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 201
9. the cover removed by means of a Phillips screwdriver PHO size Following the contrast setting the case cover has to be mounted while checking the correct fit of the inserted seal Repair Repairs may only be carried out by the manufacturer The device must be replaced if the remote transmission device is defective Innotas Produktions GmbH Installation and Operating Instructions Friedrich Engels Str 46 D 15745 Remote Transmission Device 49 3375 529649 0 RAMOC VD5 MO8 3 49 3375 529649 24 Email info innotas service de www innotas service de Last update 06 06 2014 Page 5 7 Configuration of the device The configuration of the device is performed in two steps 1 Basic configuration for GSM usage The default setting of the device is done by the manufacturer This ensures that the device automatically logs in into the mobile network after the SIM card has been inserted and the device is powered on With that the device can be accessed remotely for further application specific settings in accordance with point 2 In order to do so the customer has to specify its network service provider with his order 2 Configuration of the message concept and of inputs The configuration of inputs input type thresholds debouncing etc und the message concept reporting cycles event driven massages is carried out by remote access via the Internet control center o notas configuration of RAMOC VD
10. y sliding the metal slide in the direction of cable glands and folding up the SIM card holder Insert the SIM card and make sure that the chip on your SIM card points towards cable glands and the corner recess points away from the motherboard 4 Close SIM card holder and lock by sliding the metal slide back SIM card holder To opefi it push Obere recesi the slide to the left SIM card Power supply connection 1 Disconnect the power supply eg remove mains plug from socket 2 Remove the device cover 3 Remove upper visible circuit board Sensor connection board by unscrewing the four screws carefully and disconnect it from the lower circuit board Main Board by carefully disconnecting the internal flat ribbon cable 4 Thread the power supply cable through the small cable entry of the case strip a length of about 5 mm of the cable wires and connect them to the power supply terminal clamps of the main board Thereby observe the right polarity Labelling Colour of Terminal Clamp Meaning eseses s sSCS Voltage orange Supply ventas plus 6 25 V DC oe dark gray dark gray Supply voltage minus GND voltage minus GND Hia orange a battery 12V plus polarity a dark gray Rechargeable battery 12V minus polarity GND Note The rechargeable battery circuit will only be active after its activation by the control center 5 Tighten the small gland 1 Unscrew the four screws in order to remove the up