Home
Hilti 411279 Use and Care Manual
Contents
1. n wm o PMPAS Bedienungsanleitung de Operating instructions en Mode d emploi fr Istruzioni d uso it Manual de instrucciones es Manual de instruc es pt Gebruiksaanwijzing nl O ny es xpnoewc el Rie ja MESA ko cn ce i Dr o w OL _ 10 20m ORIGINAL OPERATING INSTRUCTIONS PMP 45 point laser It is essential that the operating instructions are read before the tool is operated for the first time Always keep these operating instructions together with the tool Ensure that the operating instructions are with the tool when it is given to other persons Contents Page 1 General information 11 2 Description 12 3 Accessories 13 4 Technical data 14 5 Safety instructions 14 6 Before use 16 7 Operation 16 8 Care and maintenance 18 9 Troubleshooting 18 10 Disposal 19 11 Manufacturer s warranty 19 12 EC declaration of conformity 20 E These numbers refer to the corresponding illustra tions The illustrations can be found on the fold out cover pages Keep these pages open while studying the operating instructions In these operating instructions the designation the tool always refers to the PMP 45 point laser Component
2. 8 4 Hilti calibration service We recommend that the tool is checked by the Hilti calibration service at regular intervals in order to verify its reliability in accordance with standards and legal requirements Use can be made of the Hilti calibration service at any time but checking at least once a year is recommended The calibration service provides confirmation that the tool is in conformance on the day it is tested with the specifications given in the operating instructions The tool will be readjusted if deviations from the manufacturer s specification are found After check ing and adjustment a calibration sticker applied to the tool and a calibration certificate provide written verification that the tool operates in accordance with the manufacturer s specification Calibration certificates are always required by com panies certified according to ISO 900x Your local Hilti Center or representative will be pleased to provide further information 9 Troubleshooting Fault Possible cause Remedy The tool can t be switched on The battery is exhausted Replace the battery The battery is inserted the wrong Insert the battery correctly way round incorrect polarity The battery compartment is not closed The tool or the on off switch is faulty Close the battery compartment If necessary the power tool should be repaired by Hilti Service Individual laser beams don t fun
3. The PMP 45 is a self levelling point laser which allows a single person to level plumb align and transfer right angles quickly and accurately The tool features five coincident laser beams beams that originate from the same point All beams have the same range of 30m range depends on the brightness of ambient light The tool is designed for use mainly in interiors for determining and checking vertical lines alignment lines and for marking plumb points When used for outdoor applications care must be taken to ensure that the general conditions are similar to those encountered indoors For example Marking the position of partition walls at right angles and in the vertical plane Aligning components to be installed or sections of a structure in three axes Checking and transferring right angles Transferring measuring marks from the floor to the ceiling Modification of the tool is not permissible Observe the information printed in the operating instructions concerning operation care and maintenance To avoid the risk of injury use only genuine Hilti accessories and insert tools The tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not as directed 2 2 Features Highly accurate horizontal and vertical beams 3 mm at 10 m Self levelling to within 5 in all directions Short self levelling time 3 seconds When the self leveling range is exceeded the laser beam blinks
4. NOTE If d3 is to the right of d1 the sum of the horizontal distances d1 d3 and d2 d4 must be no greater than 3 mm at a working distance of 5m NOTE If d3 is to the left of d1 the difference between the horizontal distances d1 d3 and d2 d4 must be no greater than 3 mm at a working distance of 5m 17 8 Care and maintenance 8 1 Cleaning and drying 1 Blow dust off the lenses 2 Do not touch the glass with the fingers 3 Use only a clean soft cloth for cleaning If neces sary moisten the cloth slightly with pure alcohol or a little water NOTE Do not use any other liquids as these may damage the plastic components Observe the temperature limits when storing your equipment This is particularly important in winter summer if the equipment is kept inside a motor vehicle 25 C to 63 C 13 F to 145 F gt 8 2 Storage Remove the tool from its case if it has become wet The tool its carrying case and accessories should be cleaned and dried at maximum 40 C 104 F Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used after along period of storage or transportation Remove the batteries from the tool before storing it for a long period Leaking batteries may damage the tool 8 3 Transport Use the Hilti toolbox or packaging of equivalent quality for transporting or shipping your equipment CAUTION Always remove the batteries before shipping the tool
5. Implied warranties of merchantability or fitness for a par ticular purpose are specifically excluded For repair or replacement send the tool or related parts immediately upon discovery of the defect to the address of the local Hilti marketing organization provided This constitutes Hilti s entire obligation with regard to warranty and supersedes all prior or contempor aneous comments and oral or written agreements concerning warranties 12 EC declaration of conformity Designation Point laser Type PMP 45 Year of design 2009 We declare on our sole responsibility that this product complies with the following directives and standards EN 55014 1 EN 55014 2 EN 61000 6 3 EN 61000 6 2 2004 108 EC 2006 95 EC 20 Hilti Corporation D Este me es Tassilo Deinzer Head BU Measuring Systems Dietmar Sartor Head of BA Quality and Process Management Business Area Electric Tools amp Ac cessories 02 2010 BU Measuring Systems 02 2010 a i Hilti Corporation LI 9494 Schaan Tel 423 234 21 11 Fax 423 234 2965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3773 0310 00 Pos 1 1 Printed in Liechtenstein 2010 41 3266 A Right of technical and programme changes reserved SE amp 0
6. substances e Do not charge the batteries f Do not solder the batteries into the tool g Do not discharge the batteries by short circuiting as this may cause them to overheat and present a risk of personal injury burns h Do not attempt to open the batteries and do not subject them to excessive mechanical stress i Do not use damaged batteries j Do not mix old and new batteries Do not mix batteries of different makes or types 5 5 Electrical 5 6 Liquids Under abusive conditions liquid may leak from the battery Avoid contact If contact accidentally oc curs flush with water In the event of the liquid coming into contact with the eyes rinse the eyes with plenty of water and consult a doctor Liquid ejected from the battery may cause irritation or burns 15 CH 6 1 Inserting the batteries EJ DANGER Use only new batteries 1 Remove the foot from the tool 2 3 Open the battery compartment Remove the batteries from the packaging and insert them in the tool NOTE Only batteries recommended by Hilti may be used to power the tool Check that the battery terminals are positioned correctly as shown on the underside of the unit Close the battery compartment Check that the catch engages properly Refit the foot to the tool 7 Operation 7 2 2 Marking out the position of light fittings e 7 1 Operation 7 1 1 Switching the laser beams on Press the on off button once 7 1 2 Switchin
7. con ditions of jobsite use as with other optical and electronic instruments e g binoculars spec tacles cameras it should be treated with care 0 Although the tool is protected to prevent entry of dampness it should be wiped dry each time before being put away in its transport container p Check the accuracy of the measurements several times during use of the tool 5 2 Proper organization of the work area a Secure the area in which you are working and take care to avoid directing the beam towards other persons or towards yourself when setting up the tool b Avoid unfavorable body positions when working on ladders or scaffolding Make sure you work from a safe stance and stay in balance at all times c Measurements taken through panes of glass or other objects may be inaccurate d Ensure that the tool is set up on a steady level surface not subject to vibration e Use the tool only within its specified limits f If several laser tools are used in the same work ing area care must be taken to avoid confusing the beams g Magnetic fields may affect the accuracy of the tool It must thus be kept away from magnetic objects The tool is not affected by the Hilti universal adapter h Do not use the tool in the proximity of medical instruments 5 3 Electromagnetic compatibility Although the tool complies with the strict require ments of the applicable directives Hilti cannot en tirely rule out the possibilit
8. ction The tool can be switched on but no laser beam is visible unit is faulty unit is faulty The laser source or laser control The laser source or laser control If necessary have the power tool repaired by Hilti Service If necessary have the power tool repaired by Hilti Service The temperature is too high or too low Allow the tool to cool down or warm up Fault Possible cause Remedy Automatic leveling doesn t The tool is set up on an excessively Set up the tool on the level function inclined surface If necessary have the power tool repaired by Hilti Service The tilt sensor is faulty 10 Disposal WARNING Improper disposal of the equipment may have serious consequences The burning of plastic components generates toxic fumes which may present a health hazard Batteries may explode if damaged or exposed to very high temperatures causing poisoning burns acid burns or environmental pollution Careless disposal may permit unauthorized and improper use of the equipment This may result in serious personal injury injury to third parties and pollution of the environment Most of the materials from which Hilti tools or appliances are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrangements for taking back old tools or appliances for recycling Ask Hilti Customer Service or your Hilti representati
9. g the tool laser beams off Press the on off button until the laser beam is no longer visible and the LED goes out NOTE The tool switches itself off automatically after approx 15 min 7 1 3 Deactivating the automatic power off feature Press and hold the on off button for approx 4 sec until the laser beam blinks three times as confirma tion NOTE The tool will be switched off when the on off button is pressed or when the batteries are exhausted 7 2 Examples of applications 7 2 1 Setting out drywall track for a partition wall 7 3 Checking 7 3 1 Checking the plumb point El 1 Foi A Make a mark on the floor a cross in a high room e g in a stairwell or hallway with a height of 5 10 m Place the tool on a smooth level horizontal surface Switch the tool on Position the tool with the lower beam on the center of the cross Mark the position of the vertical beam on the ceiling Attach a piece of paper to the ceiling before making the mark Pivot the tool through 90 NOTE The lower plumb beam must remain on the center of the cross Mark the position of the vertical beam on the ceiling 8 Repeat the procedure after pivoting the tool through 180 and 270 NOTE The resulting 4 marks form a circle in which the intersection of the diagonals d1 1 3 and d2 2 4 marks the exact center of the plumb point 9 Calculate the accuracy as described in section 7 3 1 1 7 3 1 1 Calcula
10. izontal EI El 1 Position the tool with the lower plumb beam on the center of a reference cross in the middle of a room at a distance of approx 5 meters from the walls so that the vertical laser line lies exactly in the center of the laser point 2 Attach a second target plate or sheet of paper b to the wall at the half way position as shown in the illustration Mark the mid point d1 of the right hand perpendicular beam 3 Pivot the tool clockwise through exactly 90 as seen from above The lower plumb beam must remain in the center of the reference cross and the center of the left hand perpendicular beam must then lie exactly on the vertical line of target plate a 4 Mark the center point d2 of the right hand perpendicular laser beam on target plate c 5 Mark the position of the laser point d3 on the target plate b or on a sheet of paper as at step 7 NOTE The horizontal distance between d1 and d3 must be no greater than 3 mm at a working distance of 5 m 6 Pivot the tool clockwise through exactly 180 as seen from above The lower plumb beam must remain in the center of the reference cross and the center of the right hand perpendicular beam must then lie exactly on the vertical line of target plate a 7 Then mark the center point d2 of the left hand perpendicular laser beam on target plate c NOTE The horizontal distance between d2 and d4 must be no greater than 3 mm at a working distance of 5 m
11. parts El D On off button LED Pendulum Removable foot 5 Mounting hole 1 General information 1 1 Safety notices and their meaning DANGER Draws attention to imminent danger that could lead to serious bodily injury or fatality WARNING Draws attention to a potentially dangerous situation that could lead to serious personal injury or fatality CAUTION Draws attention to a potentially dangerous situation that could lead to slight personal injury or damage to the equipment or other property NOTE Draws attention to an instruction or other useful information 1 2 Explanation of the pictograms and other information Warning signs General warning 11 Symbols CN Read the Disposal of operating power tools or instructions appliances and before use batteries together with household waste is not permissible Laser class 2 according to EN 60825 3 2007 CAUTION LASER RADIATION DO NOT STARE INTO BEAM 620 690nm 0 95mW max CLASS II LASER PRODUCT Laser class II according o CFR 21 8 1040 FDA Location of identification data on the tool The type designation and serial number can be found on the type identification plate on the tool Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department Type Serial no 2 Description 2 1 Use of the product as directed
12. sion they should be worn only when working with this tool Do not wear the laser visibility glasses while driving a vehicle on a public road 13 4 Technical data Right of technical changes reserved Range of the points 30 m 98 ft Accuracy of the points Distance 10 m 30 ft 3 mm tys in Self leveling time 3 s typical Laser class Class 2 visible 620 690 nm 10 nm EN 60825 3 2007 IEC 60825 3 2007 class II CFR 21 1040 FDA Beam diameter Distance 5 m lt 4 mm Distance 20 m lt 16 mm Self leveling range 5 typical Automatic power off Activated after 15 min Operating status indicator LED and laser beams Power supply AA size batteries Alkaline batteries 4 Battery life Operating temperature range Storage temperature Dust and water spray protection except battery compartment Tripod thread tool Tripod thread foot Weight Dimensions Alkaline battery 2 500 mAh Temperature 25 C 77 F 30 h Typical Min 10 C Max 50 C 14 to 122 F Min 25 C Max 63 C 13 to 145 F IP 54 as per IEC 529 UNC BSW s UNC 1 4 With foot but without batteries 0 413 kg 0 911 Ibs With foot 140 mm X 73 mm X 107 mm Without foot 96 mm X 65 mm X 107 mm 5 Safety instructions In addition to the information relevant to safety given in each of the sections of these operating instructions the following points mus
13. t be strictly observed at all times 5 1 General safety rules a Check the accuracy of the tool before using it to take measurements b The tool and its ancillary equipment may present hazards when used incorrectly by untrained per sonnel or when used not as directed c To avoid the risk of injury use only genuine Hilti accessories and additional equipment d Modification of the tool is not permissible e Observe the information printed in the operat ing instructions concerning operation care and maintenance f Do not render safety devices ineffective and do not remove information and warning notices 9 Keep laser tools out of reach of children h Take the influences of the surrounding area into account Do not expose the tool to rain or snow and do not use it in damp or wet conditions Do not use the tool where there is a risk of fire or explosion i Check the condition of the tool before use If the tool is found to be damaged have it repaired at a Hilti service center j The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses k When the tool is brought into a warm environ ment from very cold conditions or vice versa allow it to become acclimatized before use I If mounting on an adapter check that the tool is screwed on securely m Keep the laser exit aperture clean to avoid meas urement errors n Although the tool is designed for the tough
14. tion of accuracy 10 x di d2 mm R 1 RH m 4 ao d1 d2 inch 2 ft 4 The result R provided by this formula RH room height refers to the tool s accuracy in mm at 10 m formula 1 This result R should be within the specification for the tool 3 mm at 10 m 7 3 2 Checking leveling of the forward beam D 1 Place the tool on a smooth level surface approx 20 cm from the wall A with the laser beam directed toward the wall A 2 Mark the position of the laser point on the wall A with a cross 3 Pivot the tool through 180 and mark the position of the laser point on the opposite wall B with a cross 4 Place the tool on an even level surface approx 20 cm from the wall B with the laser beam directed toward the wall B 5 Mark the position of the laser point on the wall B with a cross 6 Pivot the tool through 180 and mark the position of the laser point on the opposite wall A with a cross 7 Measure the distances di between 1 and 4 and d2 between 2 and 3 8 Mark the mid points of d1 and d2 If the reference points 1 and 3 are located on different sides of the mid point then subtract d2 from d1 If the reference points 1 and 3 are located on the same side of the mid point then add d1 and d2 together 9 Divide the result by twice the length of the room room length x 2 The maximum permissible error is 3 mm at 10 m 7 3 3 Checking perpendicularity hor
15. to warn the user The PMP 45 is characterized by its ease of operation and use its rugged plastic casing and ease of transport due to its compact dimensions and light weight When in normal operating mode the tool switches itself off after 15 minutes Sustained operating mode can be selected by pressing the on off button for four seconds 2 3 Information displayed during operation LED The LED doesn t light The tool is switched off The LED doesn t light The batteries are exhausted The LED doesn t light The batteries are inserted incorrectly The LED lights con The laser beam is switched on The tool is in stantly Operation The LED blinks twice The batteries are almost exhausted every 10 seconds Laser beam The laser beam blinks The batteries are almost exhausted 2 4 Items supplied with the point laser cardboard box version 1 PMP 45 point laser Soft pouch 4 Batteries 3 Accessories twice every 10 seconds The laser beam blinks rapidly Operating instructions Manufacturer s certificate The tool cannot level itself Tripod PMA 20 Target plate PMA 54 55 Magnetic holder PMA 74 Telescopic brace PUA 10 Frame clamp PMA 25 Universal adapter PMA 78 Hilti toolbox PMA 62 Laser visibility glasses PUA 60 The laser visibility glasses are not protective glasses and thus do not protect the eyes from laser beams As the laser visibility glasses restrict color vi
16. ve for further information For EC countries only Disposal of electric tools together with household waste is not permissible In observance of European Directive 2002 96 EC on waste electrical and electronic equipment and its implementation in accordance with national law electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Dispose of the batteries in accordance with national regulations 11 Manufacturer s warranty Hilti warrants that the tool supplied is free of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instructions and the technical system is maintained This means that only original Hilti consumables components and spare parts may be used in the tool This warranty provides the free of charge repair or replacement of defective parts only over the entire lifespan of the tool Parts requiring repair or replace ment as a result of normal wear and tear are not covered by this warranty Additional claims are excluded unless stringent na tional rules prohibit such exclusion In particular 19 Hilti is not obligated for direct indirect incidental or consequential damages losses or expenses in connection with or by reason of the use of or inability to use the tool for any purpose
17. y of the tool being subject to interference caused by powerful electromagnetic radiation leading to incorrect operation Check the accuracy of the tool by taking measurements by other means when working under such conditions or if you are unsure Likewise Hilti cannot rule out the pos sibility of interference with other devices e g aircraft navigation equipment 5 4 Laser classification for laser class 2 class Il appliances Depending on the version purchased the tool com plies with Laser Class 2 in accordance with 1EC825 3 2007 EN60825 3 2007 and Class II in accordance with CFR 21 1040 FDA This tool may be used without need for further protective measures The eyelid closure reflex protects the eyes when a per son looks into the beam unintentionally for a brief moment This eyelid closure reflex however may be negatively affected by medicines alcohol or drugs Nevertheless as with the sun one should not look directly into sources of bright light Do not direct the laser beam toward persons a Insulate or remove the batteries before shipping the tool b To avoid pollution of the environment the tool must be disposed of in accordance with the cur rently applicable national regulations Consult the manufacturer if you are unsure of how to proceed c Keep the batteries out of reach of children d Do not allow the batteries to overheat and do not expose them to fire The batteries may explode or release toxic
Download Pdf Manuals
Related Search
Related Contents
HOGEN S SERIES 2 HYDROGEN GENERATOR ECM Series Eletric Furnaces Installation Manual Groundsmaster® 300 Series Ematic 2 Graphics Tablet User Manual Product Instructions A Software for Facility Layout with Queueing Nilfisk D-PG 140.4-9 X-TRA Cooler Master Elite 343 Manual V.1 Copyright © All rights reserved.