1. ECSL 0601A D Electronic Combination Controller User s manual FEATURES 1 Four Codes Capacity a Super Code Reset lock back to manufacturer default status b Master Code Open lock set lock functions and manage manager Manufacturer default code 1 2 3 4 5 6 c Manager Code Open lock and manage user No default setting and end user need to set code before operating lock d User Code Open lock No default setting and end user need to set code before operating lock 2 Wrong Entry Penalty Entry of four 4 consecutive invalid codes results in a 5 minute delay period i The unit beeps at 5 second intervals ii During delay period removing batteries the controller stops counting time reinstalling batteries the entrypad continues to count down until 5 minutes delay period finishes 3 Standby Status The controller will turn into a standby status with a long beep sound if there is no operation in 10 seconds after the system is activated 4 Automatic Re lock The controller will re lock in 4 seconds after a valid entry is made and the door is open 5 Low Battery Alert a Controller repeated beeping during an unlocking indicates that the battery is low and needs immediate replacement b Manufacturer recommends the use of 9 Volt premier alkaline batteries and an annual maintenance replacement of the batteries 6 Single and Dual User Mode a Single Mode Open lock with one 1 code manager or user co
2. aster code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 1 One Beep sounds which prompts to enter a code for manager Enter a desired six 6 digits code once One Beep sounds which indicates the entry is valid Re enter the six 6 digits code One Beep sounds which indicates the codes entered in steps c and d are the same and the adding manager process is successful If Two Beeps sound the process fails Repeat steps a to d Verify the new manager code at least 3 times before closing the door to make sure the code is correct Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to standby status 9 3 Add User a Note Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 1 One Beep sounds which prompts to enter a code for user Enter a desired six 6 digits code once One Beep sounds which indicates the entry is valid Re enter the six 6 digits code One Beep sounds which indicates the codes entered in steps c and d are the same and the adding user process is successful If Two Beeps sound the process fails Repeat steps a to d Verify the new user code at least 3 times before closing the door to make sure the code is correct Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to sta
3. de b Dual Mode Open lock with two 2 codes manager and user code 7 Time Delay and Time Window a Time Delay A time period waiting for opening lock The maximum Time Delay is forty 40 minutes b Time Window A time period for entering code s to open lock after Time Delay The maximum Time Window is twenty 20 minutes USER OPERATING INSTRUCTIONS I ALWAYS PERFORM THIS OPERATION WITH THE CONTROLLER OPEN Before closing the door make sure all the changes are correct QUICK START 1 Change Master Code d Enter OQ six times One Beep sounds which indicates the entry is valid and the system is waiting for code changing Enter the default master code 1 2 3 4 5 6 once One Beep sounds which indicates the entry is valid Enter a new six 6 digits code once One Beep sounds which indicates the entry is valid Re enter the new six 6 digits code One Beep sounds which indicates the codes entered in steps c and d are the same and the code changing process is successful If Two Beeps sound the changing process fails The existing code is still valid Repeat steps a to d Record the new master code Note a Verify the new master code at least 3 times before closing the door to make sure the code 1s correct Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to standby status 2 Add Manager a Note Enter the m
4. k signals One Beep every ten 10 seconds and then Four Beeps at the end of Time Delay period to start Time Window period Re enter user or manager code to unlock 2 Dual User Mode a Enter user and manager manager and user codes One Beep and then Four Beeps sound which indicates the lock goes into Time Delay period The lock signals One Beep every ten 10 seconds and then Four Beeps at the end of Time Delay period to start Time Window period Re enter user and manager manager and user codes to unlock 1 CHANGING YOUR BATTERY 1 Slide the keypad housing up and carefully pull away from mounting surface to gain access to the battery compartment 2 Remove 9 Volt Alkaline battery and replace with new one 3 CAUTION Hold onto the keypad housing and battery terminal to avoid pulling wires out of housing 4 Carefully position the keypad over the mounting screws and slide the keypad housing down Ensure that there are no wires or cables trapped between the input pad and the safe door Pinched cables can result in a short circuit gt D om o Oc T x lt x TROUBLE SHOOTING If you have any issues with your electronic lock e Please make sure the connection from the wire to the keypad is secure e Please replace the 9 Volt battery with a new one e If you still have issues please contact Mesa Safe Company Tech Support at 800 490 5624 or 714 891 8356 Mon Fri 8 00am 5 00pm PST Specification
5. ndby status 4 Open Lock Single User Mode a b Enter user or manager code The lock signals One Beep and opens 5 Change Manager or User Code a Enter 0 six times One Beep sounds which indicates the entry is valid and the system is waiting for code changing 6 Note Enter the existing six 6 digits manager or ser code once One Beep sounds which indicates the entry is valid Enter a new six 6 digits code once One Beep sounds which indicates the entry is valid Re enter the new six 6 digits code One Beep sounds which indicates the codes entered in steps c and d are the same and the code changing process is successful If Two Beeps sound the changing process fails The existing code is still valid Repeat steps a to d Verify the new code at least 3 times before closing the door to make sure the code is correct Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to standby status 6 Disable Manager a Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 2 Double Beeps sound the disabling manager is successful Enter the disabled manager code to make sure the code is disabled 7 Enable Manager Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 1 Double Beeps sound the enabling manager is s
6. s Power Supply DC 9V Power Supply Range DC 4 5V 12V Standby Current lt 15uA Active Current lt 20mA Battery Low Voltage 5 2 0 2V Working Temperature 25 C 60 C Working Humidity lt 95 Storage Temperature 45 C 85 C Password Length 6 Digits Mechanical System Life Span gt 100 000 Cycles Model ECSL 0601A D User s Manual Version V1 0020080108 E SecuRam Systeme Inc U S A
7. sure the code is deleted 12 Set Single User Mode Manager or User Code to Unlock a Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 0 to set the lock to single user mode 13 Set Dual User Mode Manager amp User Code to Unlock a Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound b Push button 8 to set the lock to dual user mode 14 Set Time Delay amp Time Window Mode a Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 9 c Enter a six digits number dddttt in the range of 001001 040020 The first 3 digits is for Time Delay and the second 3 digits is for Time Window The maximum Time Delay is forty 40 minutes and the maximum Time Window is twenty 20 minutes For example to set fifteen 15 minutes Time Delay and three 3 minutes Time Window enter 015003 OPERATE LOCK WITHOUT TIME DELAY amp TIME WINDOW 1 Single User Mode a Enter user or manager code b The lock signals One Beep and opens 2 Dual User Mode a Enter user and manager manager and user codes b The lock signals One Beep and opens 10 OPERATE LOCK WITH TIME DELAY amp TIME WINDOW 1 Single User Mode a C Enter user or manager code One Beep and then Four Beeps sound which indicates the lock goes into Time Delay period The loc
8. uccessful Verify the enabled code at least 3 times before closing the door to make sure the code is correct Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to standby status 8 Delete Manager a C Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 3 Double Beeps sound the deleting manager is successful Enter the deleted manager code to make sure the code is deleted 9 Disable User a Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound Push button 2 Double Beeps sound the disabling user is successful Enter the disabled user code to make sure the code is disabled 8 10 Enable User a Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound b Push button 1 Double Beeps sound the enabling user is successful Note a Verify the enabled code at least 3 times before closing the door to make sure the code is correct b Operations between adjacent steps need be completed in 10 seconds Otherwise the lock system sets back to standby status 11 Delete User a Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound b Push button 3 Double Beeps sound the deleting user is successful c Enter the deleted user code to make
Download Pdf Manuals
Related Search
Related Contents
User Manual - SIGLENT Technologies America Ficha Técnica Ceminstant Postes Contenimento e trasporto chimici 2 CPUs Series Ponto PO3047, PO3147 e PO3247 REQUISITOS PARA LA INSCRIPCIÓN COMO EC171809-Eyezone VIP.. E L L Eave.,.er Produit vert, éco-consommation : mode d`emploi Temblor™ T8 Copyright © All rights reserved.