Home

Illumine CLI-EMM030895 Instructions / Assembly

image

Contents

1. 7 Engage the black wire connector of the light kit assembly with the black wire connector of the motor connector Make sure the connector latches are closed properly 16 Remove one of the screws from the light kit adapter Retain for future installation Loosen the p sles N KARTET two remaining screws in the light kit adapter for installation of the light kit assembly s OE SONN LIGHT KIT 17 Carefully tuck all wires and connectors under the ESSE mp MOTOR light kit assembly while installing the light kit O ya CONNECTOR assembly to the light kit adapter AVENGED SO Sri WHITE WIRE NOTE Do not pinch wires between the light kit Nay SS J i 4 SONNET IOR assembly and the light kit adapter 18 Place the light kit assembly onto the light kit adapter Rotate the light kit assembly clockwise on the light kit adapter to engage the keyholes onto the loosened screws Retighten the two screws and reinstall the screw previously removed Tighten all three screws securely Figure 8 19 You have now partially completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan LIGHT KIT ASSEMBLY Figure 8 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit 4 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 Ib
2. four blades and flanges NOTE Take care not to scratch fan housing when installing blades 11 Install one blade assembly on the top of the motor housing using two 1 4 20 x 1 2 pan head screws with lockwashers supplied Figure 5 12 Repeat this procedure for the remaining four blades assemblies n WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WASHER HEAD SCREW 3 per blade flange Figure 4 1 4 20 x 1 2 PAN HEAD SCREW WITH LOCKWASHER 2 per bladefflange ii cee BLADE FLANGE ASSEMBLY MOTOR HOUSING Figure 5 Ceiling Fan Assembly continued 13 Remove one of the screws from the motor housing MOTOR HOUSING Retain for future installation Loosen the two CREW 3 Se LIGHT KIT remaining screws in the motor housing for 2 ADAPTER installation of the light kit adapter errr Ca KEY HOLE Z Fe gt L SLOT 2 14 Position the light kit adapter onto the motor housing Rotate the adapter clockwise to engage the keyhole slots onto the two loosened screws of the motor housing Reinstall the screw previously removed and tighten the three screws to complete the light kit adapter installation Figure 6 15 Engage the white wire connector of the light kit assembly with the white wire connector of the motor connector Figure
3. READ AND SAVE THESE INSTRUCTIONS Safety Instructions a WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in a manner Intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and keep it for future reference 2 Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades while they are turning 4 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2011 and Local Electrical Codes Use the Nationa Electrical Code if Local Codes do not exist The celling fan must be grounded as a precaution agalnst possible electrical shock Electrical installation should be made or approved by a li
4. censed electrician 3 The outlet box and joist must be securely mounted and capable of rellably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician If in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an Isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product Is designed to use only those parts supplied wlth this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with thls product by Emerson could result in personal injury or property damage WARNING To reduce the risk of personal i
5. move the hanger ball Retain the pin and hanger ball for reinstaliation in Step 6 HANGER BALL 2 Loosen the two setscrews in the motor coupler to SETSCREW prepare for the installation of the downrod Figure 2 Figure 1 3 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to SS a HAIRPIN CLIP push the straight leg of the hairpin clip through the sh hole near the end of the clevis pin until the curved ek DOWNROD portion of the hairpin clio snaps around the clevis pin MOTOR COUPLER The hairpin clip must be properly installed to prevent REINSTALL the clevis pin from working loose Pull on the SETSCREW 2 a ae downrod to make sure the clevis pin is properly 7 le Hf ie installed 4 While pulling up on the downrod tighten the two setscrews in the motor coupler Figure 2 Figure 2 A WARNING It is critical that the clevis pin fn the motor coupler is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 2 could result in the fan falling Ceiling Fan Assembly continued 5 Make sure the grommet is properly installed in the co
6. njury do not bend the biade flange when Installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control Modei No SW405 manufactured by Rhine Electric Co LTD NOTE All setscrews must be checked and re tightened where necessary before installation DATE CODE a i a a The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use Unpacking Instructions WARNING PACKAGE CONTENTS Do not install or use fan if any part Is damaged or missing Part Description Quantity B Cellng Canopy oo D Blade Ranges CS 1 Light Kit Assembly Aa WARNING This product Is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitutlon of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view Illustration HARDWARE CONTENTS Description Quantity e hain 7 1 4 20 x 1 2 Pan Head Screws with Lockwasher
7. rovides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy
8. s 8 10 32 x 1 4 Washer Head Screws g 8 32 x 3 8 Pan Head Screw Blade Balance Kit NOTE Place the parts from the loose parts bags in a small container to keep them from being Iost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding oy LE ao Sy W A Sy 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly KO S This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Wire Size A W G Up to 50 ft 14 One Phillips head screwdriver 50 100 ft 12 One stepladder One wire stripper 4 amp WARNING Before assembling your ceiling fan refer to section on Materials proper method of wirlng your fan page 9 If you feel you do not have enough wiring knowledge or Wiring outlet box and box connectors must be of type experience have your fan Installed by a licensed required by the local code The minimum wire would be electrician a 3 conductor 2 wire with ground of following size Ceiling Fan Assembly 1 Remove the hanger bail by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then re
9. s or less and use screws supplled with outlet box Most outlet boxes commonly used for support of tight flxtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubi The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Aa WARNING To avold fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middie of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows instali the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional mounting accessories Using the Celling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that p
10. upler cover then slide the coupler cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupler cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 3 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 7 The fan comes with blue black and white leads that are 80 inches iong Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 4s WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling 8 Carefully rotate the partial assembled ceiling fan and place gently into the styrofoam to compete the final installation of the fan 9 Attach the blade flange to the fan blade using the 10 32 x 1 4 washer head screw Use three screws with lockwashers per blade assembly Figure 4 10 Repeat this procedure for the remaining