1. INSTALLATION INSTRUCTIONS BUILT IN GAS AND ELECTRIC SURFACE UNITS Cooktops CABINET OPENING Prepare the cabinet accurately so your unit will fit properly Below are cabinet cutout dimensions The dimensions are for the unit to be mounted so the knobs are on the right side CHECK LOCAL CODES BEFORE MAKING CONNECTIONS 20 16 7 i 185 To Overhead Combustible Construction SS Al Saw N Ny Connection Area NN 55555553 SSP 55 SSS N ISIS N 225 L amp ELO3 283 L amp ELO5 SSS ES 30 See CABINET PREPARATIONS Section 211 16 To Adjacent Vertical Combustible Surface 1 To Adjacent Vertical Combustible Surface D 25 8 Minimum CAUTION To eliminate the hazard of reaching over the heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets INSTALLATION It is the responsibility of your installer to make certain that your range is properly installed Situations caused by improper installation are not covered under the warranty Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance IMPORTANT Read and save these instructions Save for local electrical inspect
2. A we INDICATOR LIGHT GROUND NOTICE WARNING FRAME GROUNDED TO NEUTRAL OF APPLIANCE THROUGH A LINK IT USED IN A MOBILE HOME OR IF LOCAL CODES DO NOT PERMIT GROUNDING THROUGH THE NEUTRAL DISCONNECT THE LINK FROM THE NEUTRAL AND USE GROUNDING TERMINAL OR LEAD TO GROUND UNIT IN ACCORDANCE WITH LOCAL CODES CONNECT NEUTRAL TERMINAL OR LEAD TO BRANCH CIRCUIT NEUTRAL IN USUAL MANNER CONSULT MANUFACTURER S INSTRUCTIONS WHEN CODES REQUIRE THAT 3 CONDUCTOR CORD ASSEMBLIES MUST BE REPLACED BY 4 CONDUCTOR CORD ASSEMBLIES SEE RATING PLATE FOR N TOTAL WATTAGE amp VOLTAGE 184 6C 101 REV 0
3. junction box ACCESS PLATE 2 Install the three wire range conduit and REMOVED an appropriate strain relief clamp through BLACK m the hole in the junction box LEAD Use appropriate insulated wire to connect the red and black GROUND wires from the range conduit to the TO UNIT corresponding red and black leads from the branch circuit Connect the green ground wire from the range conduit to the grounding lead from the branch circuit in like manner Geo 5 The white neutral lead from the branch circuit must be properly insulated away INSULATED STRAIN from all other leads WHITE LEAD RELIEF Secure the strain relief clamp around the CLAMP conduit and tighten the nut against the RANGE amp NUT wall of the junction box SEND Tuck all wire leads into the junction box and replace the access plate removed 240 earlier in step 1 NOTE 4 conductor connection is to be Effective January 1 1996 the National used when the appliance is installed in a Electrical Code requires that new construction mobile home or when local codes do not not existing utilize a 4 conductor connection permit grounding through the neutral to an electric range WIRING DIAGRAM FOR ELECTRIC RANGES BROIL ELEMENT OVEN THERMOSTAT DIGITAL CLOCK 4 2 LAMP G GAUGE CODE is Gis Es Ms Os Gis PART NO 180 6C130 3 12
4. must conform with local codes In addition installation must conform with the National Electric Code 70 latest edition WARNING Be sure electric power is OFF at the fuse breaker box until the unit is installed and ready to operate See appliance rating plate for maximum K W and amperage rating THREE WIRE CONDUIT CONNECTION 1 Remove the access plate to gain access BRANCH z to the electrical junction box CIRCUIT JUNCTION BOX 2 Install the three wire range conduit and appropriate strain relief clamp through the hole in the junction box p RED Use an appropriate insulated wire connector to connect the red and black wires from the range conduit to the corresponding red and black leads from the branch cireuit 4 Connect the green ground wire from the range conduit to the white neutral lead GREEN 4 from the branch circuit like manner UNT Secure the strain relief clamp around the conduit and tighten the nut against the INSULATED WIRE wall of the junction box CONNECTORS Tuck all wire leads into the junction box and replace the access plate removed earlier in step 1 STRAIN 8 JE CONDUIT Aner If local codes do not allow grounding amp NUT through the neutral refer to the 240 VAC illustration below of FOUR WIRE CONDUIT CONNECTION ere FOUR WIRE CONDUIT CONNECTION BRANCH GROUND CIRCUIT LEAD 1 Remove the access plate to gain access to the electrical
5. g Do not allow cleaners to make contact with flexible connectors The connector and its fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Connectors must comply with ANSI Z21 24 BUILT IN TOP UNITS WITH NO POWER If your built in top unit is not equipped with a power cord the unit operates by standing pilot lights or a 9 volt battery powered ignition system These units must be set up and maintained as outlined below Adjust the size of the top pilot flame until there is only a slight tip of yellow on the flame as described in the ALIGNMENTS AND ADJUSTMENTS section of the user manual The adjustment screw is located on the side of the manifold pipe Manifold Pipe and Burner Valves Top Burner Pilots Pilot Adjustment Built In Top Unit with Pilots Main Burners Not Shown On units with battery powered ignition there no top burner pilots There are top ignitor electrodes in the same location as the top burner pilots This ignition system requires one 1 9 volt alkaline battery for operation The battery is housed an enclosure underneath the switch panel cover It is recommended that you check and or replace the battery at least once per year Switch Panel Cover Spark Module Top Ignitor Electrodes Battery Enciosure Built In Top Unit with Battery Ignition Main Burners Access the battery for periodic ser
6. or s use Electrical ee GAS SURFACE UNITS MOUNTING THE BUILT IN TOP UNIT Place unit in cabinet opening with the valves on the right side Raise the top by removing top burner valve knobs and lifting upward on the front edge of the main top Secure unit to top of cabinets with four No 8 screws through holes provided in the top flanges of the burner box The gas pressure regulator supplied must be used with this unit If it is necessary to convert this unit from use with natural gas to L P or L P to natural see To Convert and or Adjust in Alignments and Adjustments section The installation must conform with local codes In the absence of local codes the National Fuel Gas Code 2223 1 latest edition A MANUAL GAS VALVE MUST BE INSTALLED IN AN ACCESSIBLE LOGATION IN THE GAS LINE EXTERNAL TO THE UNIT FOR THE PURPOSE OF TURNING ON SHUTTING OFF GAS TO THE UNIT WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut BEFORE USE or remove the grounding prong from this plug INSURE PROPER GROUND EXISTS Flexible Connectors If the gas range oven is connected to a gas supply with a metal flexible connector move the range oven with CAUTION for service or cleaning Flexible connectors are not intended for repeated bendin
7. t the burner again If the problem persists refer to the troubleshooting guide in your instruction manual or contact a service technician Once the burner has successfully lit turn the knob to adjust the flame size as needed for the amount of food being cooked or the size of the utensil WIRING DIAGRAM FOR GAS SURFACE UNITS AND WALL OVENS IGNITION LEAD CLOCK WITH TIME TOP BURNER BK IGNITION SWITCHES IGNITION IGNITION MODULE LEAD p OVEN IGNITOR SAFETY VALVE REFER ONLY TO FEATURES WHICH ARE EQUIPPED ON YOUR RANGE WARNING ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG 180 6C89 REV 1 ELECTRIC SURFACE UNITS MOUNTING THE BUILT IN TOP UNIT Place unit in cabinet opening with the knobs on the right side Raise the top by lifting upward on the front edge of the main top Secure unit to top of cabinets with four No 8 screws through holes provided in the top flanges of the burner box Make electrical connection Electrical connection should conform to local requirements and codes POWER CONNECTIONS TO APPLIANCES We suggest that you have the dealer where you purchased your new range install it or have him arrange installation by a qualified electrician Installation
8. vicing as follows Remove the burner grates top burner knobs from the unit Raise the main top by lifting it by the front edge Use a hex driver to remove four 4 screws from the switch panel cover Gently lay the switch panel cover over to the left Use a hex driver to remove one 1 screw from the battery enclosure Check and or replace the battery as recommended Reinstall the battery enclosure Reinstall the switch panel cover Lower the main top and replace the grates and knobs WIRING DIAGRAM FOR GAS RANGES AND SURFACE UNITS WITH BATTERY EQUIPMENT N IGNTION SWITCHES IF EQUIPPED BURNER IGNITION IGNITION DS MODULE THIS SECTION EQUIPPED ON RANGES WITH SEALED BURNERS THIS SECTION EQUIPPED ON RANGES OVEN IGN LEAD 9 VOLT DC SUPPLY REFER ONLY TO FEATURES WHICH ARE EQUIPPED ON YOUR RANGE 180 6C162 TOP BURNER VALVES Built in top burner valves are operated by pressing the knob and turning it 90 degrees counter clockwise to the LITE position This position is also the position where maximum gas flow is obtained Hold the knob in this position until the burner successfully lights if the burner fails to light within 10 seconds turn the knob back to the OFF position Let the unit sit at least 5 minutes to allow unburned gas to dissipate before attempting to ligh