1. Technical Bulletin 2400 Boston Street Suite 200 Baltimore Maryland 21224 Phone 410 675 2100 or 800 543 3840 Revised 3 20 2014 DAP SMARTBOND Subfloor Construction Adhesive Gun Grade e 8X more coverage than standard cartridge adhesives e One can of SMARTBOND Subfloor equals the coverage of eight 28 oz adhesive cartridges e Use with Applicator Gun for faster and easier application and precise bead control e 25 faster to apply less gunning less change out less fatigue e Unique foam collapses to form a high strength adhesive gel e Polyurethane formula provides strong durable and permanent bond e Reusable e Exceeds ASTM D3498 shear strength tests for wet frozen and dry lumber Packaging Net Wt 20 oz 567 mL aerosol can Color Tan UPC Number 0 70798 00042 1 Company Identification Manufactured For DAP Products Inc 2400 Boston St Suite 200 Baltimore Maryland 21224 Usage Information Call 1 888 DAP TIPS or visit dap com amp click on DAP Tips then Ask the Expert Order Information 800 327 3339 Fax Number 410 558 1068 Product Description DAP SMARTBOND Subfloor Construction Adhesive is a dynamic polyurethane adhesive foaming gel that is faster and easier to use than traditional cartridge adhesives Jobs become more efficient as a single can of SMARTBOND provides 8X the coverage of cartridge adhesives meaning you can do more with less The unique technology applies as a foam and transforms by
2. 20 minutes install subfloor panels amp follow published nailing fastening schedule 12 Completely shut off control knob when leaving gun unattended Reuse amp Storage Store the Applicator Gun attached to partially used foam can for up to one month If longer storage is required remove the Applicator Gun from the adhesive can and clean as directed Once the Applicator Gun is removed from the adhesive can the shelf life of DAP SMARTBOND Subfloor Construction Adhesive is greatly diminished It is not recommended to store partially used adhesive cans without the Applicator Gun attached For Best Results e To speed cure in low humidity lightly mist joists with water before application e Not recommended for applications other than subfloor and deck installations e Not for continuous water submersion e If using on concrete allow concrete to cure fully at least 28 days e Store above 60 F Product will gun slowly when cold Clean up of Tools amp Substrates Clean the Applicator Gun by removing the adhesive can and replacing it with a can of DAP SMARTBOND Cleaner Shake the can and discharge into a trash receptacle Repeat 3 or 4 times or until discharge is clear and free of adhesive residue Remove can of DAP SMARTBOND Cleaner and tighten down control valve on gun for storage Do not use DAP SMARTBOND Cleaner to clean skin Wipe excess uncured adhesive off with a paper towel Use DAP SMARTBOND Cleaner for Applicato
3. 27004 Safety Danger Extremely flammable Vapors may cause flash fire Contents under Pressure Irritant Vapor harmful May cause irritation to skin eyes and lung May cause sensitization by inhalation or skin contact INDIVIDUALS WITH LUNG OR BREATHING PROBLEMS SUCH AS ASTHMA OR PRIOR REACTION TO ISOCYANATES MUST NOT BE EXPOSED TO VAPOR May affect the brain or nervous system causing dizziness headache or nausea NOTICE Reports have associated repeated and prolonged occupational over exposure to solvents with permanent brain and nervous system damage Intentional misuse by deliberately concentrating and inhaling vapors may be harmful or fatal Harmful if swallowed Use only with adequate ventilation Do not breathe vapor Ensure fresh air entry during application and curing by opening all windows and doors and using fans or other means of ventilation Avoid contact with skin and eyes Wear protective clothing protective gloves and eye protection Vapor may ignite explosively Keep away from heat sparks and flame Do not smoke Extinguish all flames and pilot lights Turn off stoves heaters electrical motors and other sources of ignition during use and until vapor is gone Do not puncture strike or incinerate can Exposure to heat or prolonged exposure to sun may cause bursting Do not expose to heat or store at temperature above 120 F Cured product is combustible and may present a fire hazard if exposed to flame or temperatures above 240 F
4. FIRST AID SKIN DO NOT use solvents to remove product from skin Wipe excess uncured product off with a paper towel immediately and wash with warm soapy water Remaining uncured residue can be removed with petroleum jelly or baby oil For cured product soak in warm soapy water then apply petroleum jelly Cured product will wear off in time Remove contaminated clothing EYE Immediately flood with large quantities of water INHALATION Remove to fresh air INGESTION DO NOT INDUCE VOMITING Get medical attention immediately if complications arise from any exposure For emergencies call your Poison Control Center at 1 800 222 1222 See product label and Safety Data Sheet SDS for additional information For an SDS contact your supplier or visit www dap com Warranty LIMITED WARRANTY DAP Products Inc warrants that this product when applied in accordance with DAP s label technical bulletins and applicable industry standards will be free from defects in material for 15 months from the date of manufacture but makes no warranty as to appearance or color Since methods of application and on site conditions are beyond DAP s control and could affect performance DAP makes no other warranties express or implied including the warranties of Merchantability or Fitness for a Particular Use or 3 Purpose If a product defect is encountered call 1 888 DAP TIPS for warranty fulfillment You must have your sales receipt and product container available whe
5. collapsing into a high strength fast curing adhesive gel that bonds to wet dry frozen and treated lumber Screw top attaches to the Applicator Gun for faster and easier application and precise bead control Provides increased ease of use for labor intensive framing Can be applied in wet cold and freezing conditions Interior exterior use For use in all 50 states Suggested Uses Wood to wood assemblies Glued floor systems Dimensional and treated lumber Plywood OSB and Enhanced OSB Surface Preparation amp Application SAFETY FIRST PRODUCT IS EXTREMELY FLAMMABLE WHEN DISPENSING Before using read amp understand all health amp safety information product use instructions found below INSTRUCTIONS 1 Keep fingers off the trigger until ready to apply 2 Never point the nozzle at yourself or others 3 Always assume applicator gun is pressurized 4 Surface must be clean dry and free of dirt dust and other contamination 5 Always wear safety glasses gloves amp protective clothing during use 6 Shake can well before using amp intermittently during use 7 Attach adhesive applicator gun to can Do not over tighten Ensure threads are aligned to prevent leakage 8 Slowly adjust and set control knob to for desired flow 9 Gently pull trigger to release foam 10 Apply a continuous bead to floor joists with nozzle slightly above work surface Product works best on horizontal surfaces Not for overhead use 11 Within
6. n you call DAP s sole liability is either to supply replacement product or refund the purchase price DAP will in no event be liable for incidental or consequential damages An Rpm Company
7. r Gun amp Construction Adhesive or Acetone to dissolve and remove uncured construction adhesive from surfaces Cured adhesive must be mechanically removed Test surfaces to ensure surface is compatible with cleaner before cleaning Uncured adhesive may be cleaned up with DAP SMARTBOND Cleaner for Applicator Gun amp Construction Adhesive or Acetone Cured adhesive cannot be removed with solvents DO NOT use acetone or other solvents to remove product from skin SKIN CONTACT Wipe excess uncured adhesive off with a paper towel immediately Wash remaining uncured adhesive immediately with soap and water Remaining uncured residue may be removed with petroleum jelly or baby oil For cured foam soak in warm soapy water then apply petroleum jelly Cured foam will wear off in time Typical Physical amp Chemical Characteristics Vehicle Polyurethane Volatile Organic Solvent Flash Point 143 F Weight Gallon 8 26 lbs Odor Mild Color Tan Consistency Aerosol Bridging Up to 1 8 gap Shear Strength 500 800 psi Application Temperature Range Optimum Can Temperature Service Temperature Range 23 F to 105 F 50 F to 86 F 40 F to 195 F Open Time 20 Minutes 1 2 bead Full Cure 24 Hours Reusability Up to 30 days when stored as directed Interior Exterior Use Yes Freeze Thaw Stability Yes Coverage 20 oz can yields approximately 400 linear feet at 1 2 bead Shelf Life 15 months MSDS No 000101