Watlow Electric Series 97 User's Manual
Contents
1.
2. e 0 to 20mA current output into an 800Q maximum load resistance e Resolution Vdc ranges 2 5mV nominal mA ranges 5A nominal Calibration accuracy Vdc ranges 15mV mA ranges 30uA e Temperature stability 100ppm C Communications e EIA TIA 485 EIA TIA 232 e Opto isolated e Modbus RTU protocol e 1200 2400 4800 9600 19200 baud rates e 32 maximum units can be connected With additional 485 repeater hardware up to 247 units may be connected Accuracy e Input ranges Type J Oto 750 C or 32 to 1382 F Type K 200 to 1250 C or 328 to 2282 F Type T 200 to 350 C or 328to 662 F Type N Oto 1250 C or 32 to 2282 F Type E 200 to 900 C or 328to 1470 F Type C W5 0 to 2315 C or 32 to 4200 F Type D W3 Oto 2315 C or 32 to 4200 F Type PTII 0 to 1393 C or 32 to 2540 F Type R Oto 1450 C or 32 to 2642 F Type S Oto 1450 C or 32 to 2642 F Type B 870 to 1700 C or 1598 to 3092 F DIN 200 to 800 C or 328to 1472 F JIS 200 to 630 C or 328to 1166 F Modbus is a trademark of AEG Schneider Automation Thermocouple Inputs e Calibration accuracy 0 1 percent of span 1 C at standard conditions Exceptions Type T 0 12 percent of span for 200 C to 50 C 328 F to 58 F Types R and S 0 15 percent of span for 0 C to 100 C 32 F to 212 F Types B 0 24 percent of span for 870 C to 1700 C 1598 F to 3092 F e Accuracy span 540 C 1000 F minimum e Temperatur
3. 1 0 270 to 800 or 454 to 1470 F 0 1 110 0 to 800 0 C or 199 9 to 999 9 F Type C 1 0 O to 2315 C or 32 to 4200 F 0 1 0 0 to 999 9 C or 32 0 to 999 9 F Type D 1 0 O to 2315 C or 32 to 4200 F 0 1 0 0 to 999 9 C or 32 0 to 999 9 F Type PTII 1 0 0 to 1395 C or 32 to 2543 F 0 1 0 0 to 999 9 C or 32 0 to 999 9 F Type R 1 0 0 to 1760 C or 32 to 3200F Type S 1 0 0 to 1760 C or 32 to 3200 F Type B 1 0 O to 1816 C or 32 to 3300 F DIN 1 0 200 to 800 C or 328 to 1472 F 0 1 199 9 to 800 0 C or 199 9 to 999 9 F JIS 1 0 200 to 630 or 328 to 1166 F 0 1 199 9 to 630 0 C or 199 9 to 999 9 F Functionality Matrix High High 232 Universal Low Low 485 Input Event Limit Alarm Retransmit Comm Input 1 Input 2 Output 1 Output 2 Output 3 Output 4 Note These specifications are subject to change without prior notice Ordering Information SERIES 97 97 Microprocessor based s DIN with universal input 1 thermocouple and RTD Options include software power supply input 2 four outputs and display color Power Supply A 100 240Vx ac dc B 24 28Vx ac dc Auxiliary Input 2 None 1 Event input Limit Output 1 Electromechanical relay Form C Panel Cutout 2A without RC suppression 44 958 mm x 44 958 mm 1 77 in X 1 77 in Alarm Output 2a 52 070 mm gt None 2 050 in ARTA SAAT ITAL Switched dc ou
4. An Over temperature Limit Controller With User Defined Messages Watlow s SERIES 97 is a microprocessor based controller with a single input second auxiliary input and four outputs Input one is used to measure temperature from a sensor Input two can be utilized as a remote reset switch or a hardware lockout switch With up to four outputs the controller is versatile in handling applications that require a high low limit alarms retransmit and communications The control is so user friendly that it can be set up to display safety and limit messages created by the end user to meet the exact application need The SERIES 97 limit controller is added to thermal applications to limit over temperature conditions The SERIES 97 limit controller provides safety assurance against instances where a high temperature runaway condition could occur from a shorted input sensor or an output device that could fail in a closed position The SERIES 97 is recommended for any application where thermal runaway could result in large product scrap costs affect operator safety cause damage to equipment or create a fire hazard The SERIES 97 is manufactured by ISO 9001 registered Watlow Winona and reliably backed up by a three year warranty 2003 Watlow Electric Manufacturing Company Features and Benefits Programmable messages e Controller can be set up to display user programmed limit message NEMA 4X IP65 e Water and corrosion re
5. e stability 0 1 degree per degree change in ambient RTD Inputs e Calibration accuracy 0 1 percent of span 1 C at standard conditions e Accuracy span 540 C 1000 F minimum e Temperature stability 0 05 degree per degree change in ambient Agency Approvals e FM Class 3545 File J l 1B5A6 AF e NEMA 4X IP65 e CE 89 336 EEC electromagnetic compatibility directive CE 73 23 EEC low voltage directive Terminals e Touch safe e 22 to 12 AWG Power e 100 240V ac 10 percent 15 percent 50 60Hz 5 percent e 24 28V ac or V dc 10 percent 15 percent 50 60Hz 5 percent e 7 0VA maximum power consumption e Data retention upon power failure via nonvolatile memory Operating Environment e 0 to 65 C 32 to 149 F e 0 to 90 percent RH non condensing e Storage temperature 40 to 85 C 40 to 185 F Dimensions e Width 52 mm 2 05 in e Height 52 mm 2 05 in e Length 107 mm 4 2 in e Depth behind panel surface 98 4 mm 3 875 in e Approximate controller weight 0 2 kg 0 4 Ibs Allowable Operating Ranges Type J 1 0 O to 815 C or 32 to 1500 F 0 1 0 0 to 815 0 C or 32 0 to 999 9 F Type K 1 0 270 to 1370 C or 454 to 2500 F 0 1 199 9 to 999 9 C or 199 9 to 999 9 F Type T 1 0 270 to 400 or 454 to 750 F 0 1 199 9 to 400 0 C or 199 9 to 750 0 F Type N 1 0 O to 1300 C or 32 to 2372F 0 1 0 0 to 999 9 C or 32 0 to 999 9 F Type E
6. open detection bias RTD e 2 or 3 wire platinum 100Q e JIS and DIN curves e Whole or tenth degree indication e 150A nominal RTD excitation current Input 2 Event Input e Contact or voltage e 20KQ input impedance e Voltage input event high state 3 to 36V dc event low state 0 to 2V dc Resistance contact input event high state gt 23kQ event low state 0 to 2kQ Output Types Open Collector Switched DC e Open collector configuration Maximum voltage 42V dc Maximum current 200mA Maximum on resistance 1 10 Maximum offstate leakage current 100UA Switched dc configuration Switched dc supply voltage 22 to 28V dc dc supply current limited to 30mA Solid State Relay e Optically isolated e Zero cross switched e Without contact suppression e Minimum load current 0 5mA rms Solid State Relay cont e Maximum current 0 5A rms at 20 to 280V ac e Maximum offstate leakage current 10UA rms e For resistive loads only must use RC suppression for inductive loads Electromechanical Relay e Form C contact configuration e Minimum load current 10mA 5V dc e Rated resistive and inductive loads 2A 250V ac or 30V dc maximum Electrical life 100 000 cycles at rated current e For resistive loads only must use RC suppression for inductive loads Retransmit e Range selectable 0 20mA 4 20mA 0 5V dc 1 5V dc 0 10V dc e 0 to 10V dc voltage output into a 1 0009 minimum load resistance
7. sistant front panel can be washed down Microprocessor based e Accurate set point settings and quick output response Second auxiliary input e Remote reset capability Four outputs e Handles high low limit alarms communication and retransmit requirements Software and hardware lockouts e High security d WATLOW WIN 97 1203 1241 Bundy Boulevard Winona Minnesota 55987 5580 USA Phone 1 507 454 5300 ISO 9001 Fax 1 507 452 4507 Internet www watlow com e mail info watlow com Registered Company Winona Minnesota USA Printed in the USA on Recycled Paper 15 Percent Postconsumer Waste amp Specifications Controller e Microprocessor based e Universal input 1 auxiliary input 2 4 outputs e Input sample period Single input 10Hz 100 msec dual input 5Hz 200 msec digital filter adjustable e Display update 2Hz 500 msec time filter adjustable e Input Output Communication isolation e Displayed in C F Operator Interface e Dual 4 digit LED displays upper 10 2 mm 0 4 in lower 6 2 mm 0 244 in e Advance Up Arrow Down Arrow Reset tactile keys Standard Conditions For Specifications e Ambient temperature 77 F 25 C 3 C rated line voltage 50 to 60Hz O to 90 percent RH non condensing 15 minute warm up Universal Input 1 Thermocouple e Type J K T N C W5 E PTII D W3 B R S thermocouple types e gt 20MQ input impedance e Maximum 20Q source resistance e 30mA
8. tput open collector Electromechanical relay Form C 2A without RC suppression 1 2 3 4 1 LO oJ DLT O ES 0 5A solid state relay without 12 050 n RC suppression Alarm Output 3 Q A None D Electromechanical relay Form C 2A without RC suppression Auxiliary Output 4 None m 107 747 mm Electromechanical relay Form C 4 242 in 2A without RC suppression 98 425 mm By gt 3 875 in 232 Communications 485 Communications i Universal Retransmit range selectable 0 20mA 4 20mA 0 5V dc 1 5V dc 0 10V dc Software Preset Parameters 59 182 mm 2 330 in 00 Standard software Display Overlay Upper Lower i RR Red Red display RG Red Green display GR Green Red display gamm GG Green Green display 0 367 in Customer s Front Panel To be automatically connected to the nearest North American Technical and Sales Office call 1 800 WATLOW2 International Technical and Sales Offices Australia 61 39 335 6449 China 86 21 6277 2138 France 33 01 3073 2425 Germany 49 0 7253 9400 0 Italy 39 02 458 8841 Japan 81 03 5403 4688 Korea 82 02 575 9804 Malaysia 60 4 641 5977 Mexico 52 442 217 6235 Singapore 65 6773 9488 Spain 34 916 759 192 e Sweden 46 31 7014959 gt Taiwan 886 0 7 288 5168 Sweden 46 31 7014959 United Kingdom 44 0 115 964 0777