Home

Sony FWD-S47H1 User's Manual

image

Contents

1. a Function b Range Switch Code Command Control Enquiry Standby Power On 0x67 IP Setting Result 0x00 Done Yes No Enable Enable Ox01 Error 1 UART Commu 0x02 Error 2 Duplication 0x03 Error 3 IP Add Setting Ox04 Error 4 GW Add setting 0x05 Error 5 DNS1 Setting 0x06 Error 6 DNS2 Setting Ox07 Error 7 Sbnt Msk Setting 0x68 Speed Setting 0x00 100Mbps Full Duplex Yes Yes Enable Enable 0x01 100Mbps Half Duplex 0x02 10Mbps Full Duplex 0x03 10Mbps Half Duplex 0x04 Auto 0x70 Input Skip HD15 Yes Yes Disable Enable bit1 DVI bit2 Reserved bit3 VIDEO bit4 S VIDEO bit5 Reserved bit6 Reserved bit7 Reserved 0x71 Default Input 0x00 Last Memory Yes Yes Enable Enable 0x01 Option 0x74 Digital Signal Detect 0x00 VIDEO No Yes Disable Enable DVI HDMl etc 0x01 0x75 Signal Status 0x00 Stable No Yes Disable Enable Ox01 X Unstable No Signal 0x76 VIDEO Signal Detect 0x00 NTSC No Yes Disable Enable 0x01 PAL Ox7A Logo Position 0x00 Auto Yes Yes Enable Enable 0x01 Landscape 0x02 Portrait Power Management 0x00 OFF Yes Yes Disable Enable Mode 0x01 ON FWD S42H1 Code Table 1 a a Function b Range Switch Code Command Control Enquiry Standby Power On Ox7E On Screen Logo 0x00 OFF Yes Yes Enable Enable 0x01 ON Default 0x02 Reserved Ox7F LED 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x81 Power On Delay 0x00 0x78 1sec x Data Yes Yes Enable Enable 1 Auto Signal Detect becomes Disable
2. 068 36 4 4 36 4 5 ERROR resporise rient treten 37 5 5 1 5 2 5 3 6 Eitor Gn cr 39 6 1 JE ur DEN 39 6 2 Community error gt 39 6 3 Request errors 6 4 Network etit 6 5 COMM He 6 6 NVRAM error Section 1 RS 232C 1 Communication Parameters Communication method RS 232C Synchronous method Asynchronous Baud rate 9600bps Character length 8bit Parity None Start bit length 1bit Stop bit length 1bit Flow control None 2 Pin Assignment Monitor side D sub 9 pin Host side D sub 9 pin Qu e 0 6 9 8 0 8 External view External view Pin No Function Pin No Function 1 NC 1 NC 2 TXD 2 RXD 3 RXD 3 TXD 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC 3 Communication Data Format a Control message No Item Value 1 Header 0x8C Control 2 Category OxXX 3 Function OxXX 4 Data1 Length OxXX 5 Data2 Data1 OxXX OxXX OxXX X DataX OxXX X1 Check Sum OxXX Check Sum Sum total of 1 to X Lower one byte data is validated when a value exceeds 255 1byte Setthe command interval to 500 ms or more when transmitting the Control command continuously Setthe command interval to 500
3. Return Data6 Return Data7 Return Data8 Return Data9 Return Data10 Option1 Option1 Option2 Option2 Option3 Option Type Input Type Option Type Input Type Option Type Code Table Code Table Code Table Code Table Code Table 4 e 4 e 4 e 4 e 4 e Return Data11 Check Sum Option3 OxXX Completed Input Type Code Table 4 e Code Table 4 e Input Input Type Basic Option Type Input Type Option INPUT1 0x02 S Video INPUT2 0x01 Video INPUT3 0x06 RGB YUV Analog INPUT4 0x07 DVI INPUT5 0x00 No Input OPTION1 0x00 Analog Only 0x00 Input 0x00 Analog Only Ox03 Video S Video 0x00 Analog Only 0x06 RGB YUV Analog 0x00 Analog Only 0x07 Video S Video RGB YUV Analog 0x01 Analog Com 0x04 RGB 0x03 Com Only 0x00 No Input 0x04 Digital Only OxOE Digital Digital 0x04 Digital Only OxOD Digital OPTION2 0x00 Analog Only 0x00 No Input OPTION3 0x00 Analog Only 0x00 No Input FWD S42H1 23 j Auto Panel Type Detect Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x31 OxFF OxFF OxE2 Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 4 h Completed Code Table 4 h Code Table 4 1 Code Table 4 1 Panel Type H_Resolution 0x0780 1920 Input Quantity 0x05 0x00 LCD V_Resolution 0x0438 1080 Option Slot Quantity 0x01 Code Table 4 d a Function b Range Switch code Command Control
4. 0x02 Low 0x03 Option 0x10 Picture Mode 0x00 Standard Yes Yes Disable Enable 0x01 Vivid 0x02 Custom 0x05 TC Control 0x06 Conference 0x11 Brightness Boost 0x00 ON Yes Yes Disable Enable 0x01 OFF 0x30 Volume 0x00 0x64 Yes Yes Enable Enable 0x31 Treble 0x00 0x64 Yes Yes Disable Enable 0x32 Bass 0x00 0x64 Yes Yes Disable Enable 0x33 Balance 0x00 0x64 Yes Yes Disable Enable 0x34 Surround 0x00 OFF Yes Yes Disable Enable 0x01 Hall 0x02 Simulate 0x35 Sound Mode 0x00 Dynamic Yes Yes Disable Enable 0x01 Standard 0x02 Reserve 0x03 Custom Continued 14 FWD S42H1 Code Table 2 a a Function b Range Switch code Command Control Enquiry Standby Power On 0x36 Default Volume Set 0 00 0 64 Yes Yes Enable Enable Ox37 Volume Select 0x00 Last Memory Yes Yes Enable Enable 0x01 Default Setting 0x38 Max Volume Set 0x32 50 Yes Yes Enable Enable 0x46 70 0x64 100 x1 Picture Mode Vivid Only is Enabled 2 Sound Mode Custom Only is Enabled c Color Temp Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x10 Code Table 2 b a 0x03 Code Table 2 c Code Table 2 b b OxXX Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x10 Code Table 2 b a Code Table 2 c OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70 0x00
5. 0x02 Size Reset Size Shift 0x03 Picture Reset2 Contrast Brightness FW50 Chroma Phase 0x04 All Reset 26 FWD S42H1 Section 2 SNMP 1 SNMP FWD S42H1 S47HI installs SNMP Simple Network Management Protocol SNMP is a standard protocol for network management that was standardized in IETF Internet Engineer Task Force By using SNMP the management information of equipment connected to a network can be gotten via a network The information of multiple equipment gotten using SNMP can also be unitarily managed by using SNMP management software The equipment corresponding to SNMP has a management information database called MIB Manage ment Information Base in the inside of equipment In SNMP the bidirectional communication of data contained in MIB is realized between a management system and management object system that exist in a network In MIB there is the standard MIB prescribed RFC Especially MIB 2 formal name is its representative MIB MIB 2 was established to manage a network MIB 2 is installed in much network equipment such as a PC router and switch as a standard feature This unit installs this MIB 2 Monitoring and monitored sides exist when equipment is monitored via a network using SNMP The monitoring side is called an SNMP manager It is mainly constituted by the software of PC For the monitored side a module called an SNMP agent is installed SNMP compatible equ
6. 1 Continued 16 FWD S42H1 Code Table 3 b a Function b Range Switch code Command Control Enquiry Standby Power On 0x06 Auto Pixel Adjust OxFF Execute Yes No Disable Enable 0x07 Dot Phase 0x00 0x1F Yes Yes Disable Enable Multi Position 0x00 Position1 Yes Yes Disable Enable 2 2 1 2 2 1 0x01 Position2 0x02 Position3 0x03 Position4 OxOC Multi Position 0x00 Position1 Yes Yes Disable Enable 3 3 1 3 3 1 0 01 Position2 0x02 Position3 OxO3 Position4 0 04 Position5 0x05 PositionG 0x06 Position7 0x07 Position8 0x08 Position9 Multi Position 0x00 Position1 Yes Yes Disable Enable 4x4 1x4 4x1 0 01 Position2 0x02 Position3 0x03 Position4 0 04 Position5 0x05 Position6 0x06 Position7 0x07 Position8 0x08 Position9 0x09 Position10 OxOA Position11 OxOB Positioni12 OxOC Position13 OxOD 5 14 OxOE 5 15 OxOF Position16 OxOE Over Scan 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x02 AUTO OxOF Multi Display 0x00 Tiles Yes Yes Disable Enable Output Format 0x01 Window FWD S42H1 17 1 Arrangement of Multi Position Multi Position 2 x 2 Multi Position 3 x 3 1 2 Multi Position 1 x 2 3 4 1 2 Multi Position 1 x 3 Multi
7. Input Select 0x08 HD15 RGB Yes Yes Disable Enable 0x09 HD15 YUV OxOE OPTION RGB OxOF OPTION COMPONENT 0x20 DVI 0x30 VIDEO 0x31 S VIDEO 0x84 Option Digital HDMI SDI 0x85 Option Digital2 HDMI2 0x02 Force Status Display 0x00 ON Yes Yes Disable Enable 0x01 OFF 0x03 Audio Mute 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x04 Auto Status Display 0x00 ON Yes Yes Enable Enable 0x01 OFF Continued FWD S42H1 Code Table 1 a a Function b Range Switch Code Command Control Enquiry Standby Power On 0x06 Color System 0x00 Auto Yes Yes Disable Enable 0x01 NTSC 0x02 504 43 0x03 PAL 0x05 PAL M 0x06 PAL N 0x07 PAL60 OxOF Language 0x00 Japanese Yes Yes Disable Enable 0x01 English 0x02 Deutsch 0x03 Fran ais 0x04 Espa ol 0x05 Italiano 0x10 Index Number 0x01 0xFF Yes Yes Disable Enable 0x12 Standby Power 0x00 Standard Yes Yes Disable Enable 0x01 Low 0x13 Mode 0x00 Off Yes Yes Disable Enable Power Saving 0x01 High 0x02 ECO Low 0x14 Speaker Out 0x00 ON Yes Yes Disable Enable 0x01 OFF 0x18 Sync Mode 0x00 Yes Yes Disable Enable 0x01 Video Ox1B Clock Display 0x00 OFF Yes Yes Disable Enable 0x01 0x24 Input Detect 0x00 FW12 HD15 No Yes Disable Enable Option 0x02 0x03 Reserved 0x05 FW50 RGB 0x06 FW21 UART CTRL S 0x08 FW15 HDMI x 2 0x09 FW16 HD SDI Ox0A Reserved 0x0B R
8. Primary Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x63 0x05 Address 0 Address 1 Address 2 Addess3 0 00 0 0 00 0 0 00 0 Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x63 OxFF OxFF OxE4 DNS Secondary Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x64 0x05 Address 0 Address 1 Address 2 Addess3 OxXX 0 00 0 0 00 0 0x00 OxFF Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x64 OxFF OxFF OxE5 12 FWD S42H1 Player IP Address Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x83 OxFF OxFF 0x04 Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Answer Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Enquiry 0 8 0x00 Code Table 0x05 Address 0 Address 1 Address 2 Address3 1 a a Address ex 192 128 14 1 192 0xCO Address 0 128 0x80 Address 1 14 OxOE Address 2 1 0x01 Address 3 IP address command can be carried out even in the standby state Code Table 1 a a Function b Range Switch code Command Control Enquiry Standby Power On 0 42 IP Address Enable Enable Enable Enable 0x61 Subnet Mask _ 0x62 Gateway Address _
9. When Option Slot is connected Option command is Enable 2 Restricts a part of keys operation following below Remote Commander Menu Picture Sound ECO Power Saving Contrast Brightness Chroma H Shift V Shift V size PAP Main Menu 3 Digital Signal Status is Enable for Digital Input Signal Detect Function only in Stable Digital Signal or VIDEO Signal is Enable Return Signal Status of Active Window 35 Only the panel power supply is turned off at the standby when setting it 5 Analog Signal Detect Function a Mode Control Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 Code Table 1 a a Code Table 1 d OxFF OxXX Answer Header Answer Return to Data Size Return Data1 Data2 Check Sum Enquiry 0x70 0x00 0x02 Code Table 1 o OxXX Completed Code Table 1 a a Function b Range Switch Code Command Control Enquiry Standby Power On 0x78 Analog Signal Detect 0x00 VIDEO No Yes Disable Enable 0x01 Code Table 1 d Input Select 0x00 Main 1 0x01 Sub When input is no signal or not supported signal return value become Video 0x00 OxFF Present input 8 FWD S42H1 6 Priority Signal Select Function a Mode Control Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 Code Table 2 a a Code Table 2 d OxFF OxXX Answer Header Answer Return to Data Size Return Data1 Data2 Check Sum Enq
10. 0x03 Code Table 2 c Code Table 2 b b 0xXX Completed Code Table 2 b a Function b Range Switch code Command Control Enquiry Standby Power On 0x05 Red Gain 0x00 0x1E Yes Yes Disable Enable 0x06 Green Gain 0x07 Blue Gain Code Table 2 c Format Select 0x00 Cool 0x01 Neutral 0x02 Warm 0x03 Custom FWD S42H1 15 8 Size Shift a 8Bits Register Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x20 Code Table 3 b a 0x02 Code Table 3 b b OxXX Enquiry 0x83 OxFF OxFF OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 3 b b OxXX Completed Code Table 3 b a Function b Range Switch code Command Control Enquiry Standby Power On 0x00 H Size 0x00 0x3C Yes Yes Disable Enable 0x01 H Shift 0x00 0x3C Yes Yes Disable Enable 0x02 VSize 0x00 0x3C Yes Yes Disable Enable Ox03 VShift 0x00 0x3C Yes Yes Disable Enable 0x04 Aspect 0x00 Wide Zoom Yes Yes Disable Enable VIDEO Only 0x01 Zoom VIDEO Only 0x02 Full VIDEO Only 0x04 Normal PC Real VIDEO 4 3 0 05 Full 1 PC Only 0x06 Full 2 PC Only 0x05 Multi Display 0x00 OFF Yes Yes Disable Enable 0x01 2x2 0x02 3x3 0x03 4 4 0x04 1x2 0x05 1x3 0x06 1x4 0x07 2x1 0x08 3x1 0 09 4
11. 0x03 Hour 0x00 0x17 Minute 0x00 0x3B 0xXX Completed Code Table 1 f a Function b Range Switch code Command Control Enquiry Standby Power On On Timer 0x50 Sunday Yes Yes Disable Enable 0x51 Monday 0 52 Tuesday _ 0x53 Wednesday _ 0x54 Thursday _ 0x55 Friday _ 0x56 Saturday _ 0x57 Every day _ Off Timer 0x58 Sunday _ Yes Yes Disable Enable 0x59 Monday _ Ox5A Tuesday 2 0 58 Wednesday 2 0x5C Thursday _ Friday _ 0x5E Saturday _ 0x5F Every day _ FWD S42H1 11 d IP Address Setting IP Address Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x42 0x05 Address 0 Address 1 Address 2 Address3 OxXX 0x00 0xFF 0x00 0xFF 0x00 OxFF 0 00 0 Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x42 OxFF OxFF 0xC3 Subnet Mask Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x61 0x05 Address 0 Address 1 Address 2 Address3 0x00 0xFF 0 00 0 0x00 OxFF Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x61 OxFF OxFF OxE2 Gateway Address Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x62 0x05 Address 0 Address 1 Address 2 Address3 OxXX 0x00 0xFF 0 00 0 0 00 0 Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x62 OxFF OxFF 0 DNS
12. 0x63 DNS Primary _ 0x64 DNS Secondary _ 0x83 IP Address Player _ Disable Enable Enable Enable 7 Picture Sound a Picture Sound Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x10 Code Table 2 a a 0x02 Code Table 2 a b OxXX Enquiry 0x83 OxFF OxFF OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 2 a b OxXX Completed FWD S42H1 13 Code Table 2 a a Function b Range Switch code Command Control Enquiry Standby Power On 0x00 Contrast 0x00 0x64 Yes Yes Disable Enable 0x01 Brightness 0x00 0x64 Yes Yes Disable Enable 0x02 Chroma 0x00 0x32 Yes Yes Disable Enable 0x03 Phase 0x00 0x64 Yes Yes Disable Enable 0x04 Color Temp 0x00 Cool Yes Yes Disable Enable 0x01 Neutral 0x02 Warm 0x03 Custom 0x09 Sharpness 0x00 0x14 Yes Yes Disable Enable Ox0A NR 0x00 OFF Yes Yes Disable Enable 0x01 Low 0x02 Mid 0x03 High OxOB Cinema Drive 0x00 Auto Yes Yes Disable Enable 0x01 OFF Ox0C Dynamic Picture 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x02 Reserve OxOD Color Correct 0x00 Yes Yes Disable Enable 0x01 OFF OxOE Gamma Correct 0x00 High Yes Yes Disable Enable 0x01 Mid
13. 1 41 Invalid Item 01h Invalid Item Request 02h Invalid Length 03h Invalid Data 04h Short Data 11h Not Applicable Item 80h Community Error 02h Different Community 01h Request Error 10h Invalid Version 01h Invalid Category 02h Invalid Request 03h Short Header 11h Short Community 12h Short Command 13h Network Error 20 Timeout 01h Comm Error FOsckh Timeout 01h Check Sum Error 10h Framing Error 20h Parity Error 30h Over Run Error 40h Other Comm Error 50h Unknown Response FOh NVRAM Error 1 Read Error 10h Write Error 20h 6 1 Item errors An item error occurs when the Item No or Data of a request is invalid The conditions under which each error occurs are described below Invalid Item When Item No that is not supported is specified Invalid Item Request When Item No is supported but Request that is not supported is requested Invalid Length When the Data Length of the specified Item No is too long Invalid Data When the Data of the specified Item No differs in the setting range Short Data When the length of data differs from the value specified using Data Length Not Applicable Item When an item that is not valid at present is specified 6 2 Community error This error occurs when community differs FWD S42H1 39 6 3 Request errors These errors occur when a header or command is invalid The conditions under which each error occurs are described below Invalid Version When the v
14. Enquiry Standby Power On 0x00 Model Name 0x28 0x29 No Yes Enable Enable 0x01 Serial Number 0x00000000 0x0098967F 0 000 000 9 999 999 0x02 Operation Time 0x00000000 0xD693A3FF 0sec 3 599 999 999sec 0x03 Soft Version Main 0x0000 0x9999 0x07 Digital 3 3 V 0x08 Analog 24 V 0x00 0xFF 0x09 Digital 5 V Tempi 0x00 0xFF Temp2 0x00 0xFF 0x0C Temp3 0x0D Temp 5 0x00 0xFF OxOE Inverter Alarm 0 Normal 1 Abnormal OxOF Soft Version LAN 0x0000 0x9999 0x10 Analog 9 V 0 11 Shutdown Log 0x12 Digital 3 3 V Failure 0x13 Digital 5 V Failure 0x14 Analog 9 V Failure 0x00 0xFF 0x16 Analog 12 V 0 00 0 0x30 Auto Input Detect 0x31 Auto Panel Type Detect 24 FWD S42H1 k Auto Plug Detect Syntax Header Category Function Enquiry 0x83 0x30 0x32 Answer Header Answer Return to Data Size Enquiry 0x70 0x00 0x21 Data1 Data2 OxFF OxFF Return Data1 Panel Type Code Table 4 h Check Sum OxE3 Return Data2 H_Resolution H Code Table 4 i Return Data3 H_Resolution L Code Table 4 i FWD S42H1 Return Data4 V_Resolution H Code Table 4 i Return Data5 V_Resolution L Code Table 4 i Return Data6 Input Quantity Code Table 4 j Return Data7 Input1 Input Type Code Table 4 e Return Data8 Input2 Input Type Code
15. Position 2 x 1 Multi Position 3 x 1 Multi Position 4 x 1 1 2 1 2 3 1 2 3 4 1 2 3 1 4 5 6 2 7 8 9 3 Multi Position 4 x 4 Multi Position 1 x 4 1 2 3 4 1 5 6 7 8 2 9 10 11 12 3 19 14 15 16 4 FWD S42H1 b Power On Batch Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x00 0x85 0x03 Input Select Code Volume Code OxXX Table 1 a a Table 1 a b Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x85 OxFF OxFF OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 Ox71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Data2 Data3 Check Sum Enquiry 0x70 0x00 0x03 Input Select Code Volume Code OxXX Table 1 a a Table 1 a b Code Table 1 a Input Select a 0x08 HD15 RGB 0x09 HD15 YUV Option RGB 0x0F Option COMPONENT 0x20 DVI 0x30 VIDEO 0x31 S VIDEO 0x84 Option Digital HDMI1 SDI 0x85 Option Digital2 HDMI2 Volume b 0x00 0x64 Code Table 1 b a Function b Range Switch code Command Control Enquiry Standby Power On 0x85 Power On Batch Yes No Enable Control Disable 1 When this control command is received the power of a set will be turned on first 2 Input Select setting Auto Sig
16. SONY FLAT WIDE DISPLAY MONITOR 547 1 542 1 PROTOCOL MANUAL For Customer Table of Contents 1 RS 232C 1 Communication Parameters 2 Pin ASSIgn mIment u 3 Communication Data Format eere 1 4 General FunctlOn oerte rre tee ern eene inert 3 9 Analog Signal Detect Function sees 8 6 Priority Signal Select Function sees 9 1 5 p o BEARES 13 8 Si IE 16 9 Stat s Equity reete hb enr inca 20 10 User Resets u an n iles 26 2 SNMP 1 SNMP M 27 2 Specifications of SNMP Installation 28 3 Installation M 28 4 Operation of SNMP Setting Window 28 4 1 Community 4 2 Authentication Trap 4 3 Restriction Of Host e entes 30 5 Installed 5 coo teo rre res 31 6 Information to Be Notified on Trap 31 FWD S42H1 3 ID Talk Default Setting 2 3 Packet StFUCUUEO cho settee oc ei ore b de tenes 34 3 1 a 34 3 2 COMMUN 35 3 3 Command rater en 35 3 4 Request ertet eter rab gei 35 3 5 hor 35 4 Requests and Responses 36 4 1 Requests qu a 36 4 2 36 4 3
17. Table 4 e Return Data12 Option Slot Quantity Code Table 4 j Return Data9 Input3 Input Type Code Table 4 e Return Data13 Option1 Option Type Code Table 4 e Return Data10 Input4 Input Type Code Table 4 e Return Data14 Option1 Input Type Code Table 4 e Return Data11 Input5 Input Type Code Table 4 e Return Data15 Option2 Option Type Code Table 4 e Return Data16 Option2 Input Type Code Table 4 e Return Data17 Option3 Option Type Code Table 4 e Return Data18 Option3 Input Type Code Table 4 e Return Data19 Reserve OxFF Return Data20 Reserve OxFF Return Data24 Reserve OxFF Return Data21 Reserve OxFF Return Data25 Reserve OxFF Return Data22 Reserve OxFF Return Data26 Reserve OxFF Return Data23 Reserve OxFF Return Data27 Reserve OxFF Return Data28 Return Data29 Return Data30 Return Data31 Reserve Reserve Reserve Reserve OxFF OxFF OxFF OxFF Return Data32 Check Sum Reserve OxXX OxFF 25 10 User Reset Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x50 Code Table 5 0x02 OxFF OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Code Table 5 Function Range Switch code Command Control Enquiry Standby Power On 0x00 Picture Reset Yes No Disable Enable 0x01 Audio Reset
18. and SNMP management environment Community and its Community property Authentication trap Host restriction The Web server function of this unit is used for setting Refer to the Operation Manual of this unit for the operation of the Web server The contents of each item and the setting of SNMP are fully described in this specification 4 Operation of SNMP Setting Window This section describes the procedure and contents for setting of SNMP Open the Web page of this unit and click the SNMP button in the Advanced setting item on the Setup page where administrator s password is necessary The SNMP setting window is displayed Community public Display Remote Manager Community name 111077 Rights Fead On Trap destinations Send authentication trap Accept SNMP packets from any host Accept SNMP packets from these hosts SNMP Setting window on Web Page 28 FWD S42H1 4 1 Community A Community name is used as the password for SNMP access The request received from an SNMP man ager is accepted when the Community name contained in the request coincides with the Community name set The request is rejected when the former does not coincide with the latter A maximum of three Communities can be set There are Rights and Trap destinations items in the property of Community The property can be set for each set Community When multipl
19. ation of the connected display equipment Lower byte Contents SET GET 00h Category Code _ O Oth Model Name _ O 02h Serial Number _ 03h Installation Place O O 0x8000 Category code 1 byte 0x8001 Model name 12 alphanumeric characters For under 12 alphanumeric characters the remaining section is set as 00h 0x8002 Serial number 4 bytes 0x8003 Installation place 24 alphanumeric characters For under 24 alphanumeric characters the remaining section is set as 00h FWD S42H1 37 5 2 90 This item gets the network setting information Lower byte Contents SET GET 00h MAC Address _ O 01h IP Address O 02h Subnet Mask _ O 03h Default Gateway _ O 04h DHCP _ O 0x9000 MAC Address 6 bytes 0x9001 IP Address 4 bytes 0x9002 Subnet Mask 4 bytes 0x9003 Default Gateway 4 bytes 0x9004 DHCP 1 byte DHCP invalid data value 0 DHCP valid data value 1 5 3 F100h FWD S42H1 S47H1 dedicated protocol packets can be transmitted to the main microcomputer of FWD S42H1 S47HI as ID Talk data according to the FWD S42H1 S47H1 dedicated protocol The response of protocol is returned as the data of ID Talk response packets Refer to Section 1 RS 232C for details on the FWD S42H1 S47H1 dedicated protocol 38 FWD S42H1 6 Error Codes An error code list and its details are shown in the table below Category Error Error code Item Error 0
20. byte data is validated when a value exceeds 255 1byte 8 Enquiry answer Command cancel No Item Value 1 Header 0x70 Answer Answer 0x03 Command Canceled 3 Check Sum 0x73 0x03 Command Canceled Packet is correctly received but the data value is not correct or the request cannot be accepted in the current host state 2 FWD S42H1 D Error answer No Item Value 1 Header Answer 2 Answer 0x00 No Function Error 0x01 Check Sum Error 0x02 Data Length Error 3 Check Sum 0xXX 0x00 No Function Error 0x01 Check Sum Error 0x02 Data Length Error Packet header category or function code are not included in this protocol Check sum value of received packet is not correct The data size of received packet is not correct 4 General Function a Mode Control Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x00 Code Table 1 a a 0x02 Code Table 1 a b OxXX Enquiry 0x83 OxFF OxFF OxXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 1 a b 0xXX Completed Code Table 1 a a Function b Range Switch Code Command Control Enquiry Standby Power On 0x00 Power 0x00 OFF Yes Yes Enable Enable 0x01 ON 0x01
21. e Command Control Enquiry Standby Power On 0x40 Screen Saver 0x00 OFF Yes Yes Disable Enable 0x01 All White ON 0x02 Sweep 0x03 Standby 0x43 Back Light 0x00 0x64 Yes Yes Disable Enable 0x44 Logo Illumination 0x00 Logo Off Yes Yes Enable Enable 0x01 Logo On Low 0x02 Logo On High 0x45 Control Mode 0x00 Main Remocon Yes Yes Disable Enable 0x01 Main 0x02 Remocon 0x03 Off 0x04 Limited 0x46 Off Timer Mode 0x00 Every Day Repeat Yes Yes Enable Enable 0x01 Day Of Week 0x47 Timer Enable bito Sunday 1 Enable 0 Disable Yes Yes Enable Enable bit1 Monday 1 Enable 0 Disable bit2 Tuesday 1 Enable 0 Disable bit3 Wednesday 1 Enable 0 Disable bit4 Thursday 1 Enable 0 Disable 015 Friday 1 Enable 0 Disable bit6 Saturday 1 Enable 0 Disable bit7 Every day 1 Enable 0 Disable 0x48 Off Timer Enable bitO Sunday 1 Enable 0 Disable Yes Yes Enable Enable biti Monday 1 Enable 0 Disable bit2 Tuesday 1 Enable 0 Disable bit3 Wednesday 1 Enable 0 Disable bit4 Thursday 1 Enable 0 Disable bit5 Friday 1 Enable 0 Disable bit6 Saturday 1 Enable 0 Disable bit7 Every day 1 Enable 0 Disable 0x65 IP Setting Mode 0x00 DHCP Yes Yes Enable Enable 0x01 Manual 0x02 Speed 0x66 Setting Execute 0x00 Shut Down No Yes Enable Enable 0x01 IP Setting 0x02 NVR Reset 0x03 Alarm 0x04 LAN FW version Continued 6 FWD S42H1 Code Table 1 a
22. e Communities are set all set Communities are validated 1 Rights The rights that can be set are as follows Read Only An SNMP manager can reference MIB information using this Community name Read Write This Community must be set when a write request is sent from an SNMP manager Other Do not set this option because it is used for the function extension in future 2 Trap destinations When Trap destinations are set during trap occurrence a trap is notified to the equipment set as trap destinations using the Community name set Up to four Trap destinations can be set to one Community Trap destinations are not set in default LNote This product can be set on only the Web screen because it does not install the automatic setting func tion of Trap destinations 3 Setting procedure of Community Community can be added edited and removed The addition editing and removal procedures of Community are described below Addition of Community 1 Click the button The Community name Rights and Trap destinations text boxes and Set to List and Cancel buttons are validated 2 Type the Community name you want to add 3 Setthe Rights of Community and the Trap destinations you want to add When you want to save the setting click the Set to List button and then click the button at the bottom of the window Click the button when you want to discard the setting during setting When you want to save sett
23. equipment that sends a request Request This is a request for display equipment Item No This is the item number to be treated for request Data Length This is the length of data incident to a request The maximum length is 128 bytes The length of data is 0 when no data exists Data This is data incident to a request 3 5 Response The format when display equipment returns a response to the request from a host is described below Community This contains the same alphanumeric character as a request For a short header and short community this is embedded with 00h Response This contains the result of a request Item No This is the item number to be treated for response Data Length This is the length of data incident to a response The maximum length is 128 bytes The length of data is 0 when no data exists Data This is data incident to a response FWD S42H1 35 4 Requests and Responses Requests and responses are described below 4 1 Requests Requests are only a GET request that gets the display information or state and a SET request that changes the setting of display equipment Request Contents SET 00h Writes data in the register of display equipment GET 01h Gets the installation information equipment state or setting values SET command Communication with the main microcomputer of display equipment can be done via a network by using the protocol dedicated to FWD S42H1 S47H1 as
24. er Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Shutdown Log OxXX Completed Code Table 4 c Return Data1 0x00 0xFF g Shutdown Log Clear Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x30 0x11 0x02 0x00 OxCF Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled h LAN Firmware Version Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x30 0x03 Soft Version LAN Soft Version LAN OxXX Upper data Lower data Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Code Table 4 c Shutdown Information bit Reserved bit 1 FAN Sensor Abnormal 0 Normal bit2 1 Panel Temperature Abnormal 0 Normal bit3 1 Temperature Sensor Abnormal 0 Normal bit4 Reserved bits 1 Power Abnormal 3 3 V 5 V 0 Normal bite 1 Analog Power Abnormal 12 V 9 V 24 V 0 Normal bit Reserved 22 FWD S42H1 i Auto Input Detect Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x30 OxFF OxFF OxE1 Answer Header Answer Return to Return Data1 Return Data2 Return Data3 Return Data4 Return Data5 Data Size Enquiry 0x70 0x00 0 0 Input1 Input2 Input3 Input4 Input5 Input Type Input Type Input Type Input Type Input Type Code Table Code Table Code Table Code Table Code Table 4 e 4 e 4 e 4 e 4 e
25. ersion of a header is other than 2 Invalid Category When a category differs Invalid Request When a request that is not supported is specified Short Header When the received data is 1 byte Short Community When the received data 1s 2 to 5 bytes Short Command When the received data is 6 to 9 bytes 6 4 Network error This error occurs in TCP IP The conditions under which an error occurs are described below Timeout When communication was interrupted halfway 6 5 Comm error This is an error that occurs during communication with the main control microcomputer of display equip ment Timeout When the received data is not sent after data transmission Check Sum Error When a check sum error occurs in the main control microcomputer Framing Error When a framing error occurs Parity Error When a parity error occurs Over Run Error When an overrun error occurs Other Comm Error When other errors occur Unknown Response When data that cannot be processed is received 6 6 NVRAM error Read Error When the read operation from NVRAM fails Write Error When the write operation to NVRAM fails 40 FWD S42H1
26. es consisting of a version 8 bits and category 8 bits Bit position 0 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 LCD OL por Ir T T TT Version 8 Category 8 Header structure Version Indicates the version number of an ID Talk protocol This version is fixed to 02h version 2 Category Contains the category number of display equipment to be controlled A category number is confirmed on the display equipment side A request is ignored when a different category number is contained Code Category 10h Information Display 34 FWD S42H1 3 2 Community A request is executed when community coincides with the community set in display equipment Commu nity consists of four upper or lower case alphanumeric characters SONY is a factory setting value The set character can be changed on the Web page 041 2 34567 8 9 01 2 9 41516 7 8 9 0 T Community 32 Community packet 3 3 Command The format of a request packet and response packet is described below 0 1 2 3 Bit position 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 LITT rf fo rf T T H T T l1 TY 41 41 T T Hf T T H 1 Item No 16 Data Length 8 Request Response 8 Command packet 3 4 Request The format when sending a request from a host to display equipment is described below Community This is the same alphanumeric character as the community set in display
27. eserved Ox0C Reserved OxOD Reserved OxOE Reserved OxOF Not Connect Continued 4 FWD S42H1 Code Table 1 a a Function b Range Switch Code Command Control Enquiry Standby Power On 0x26 Auto Shut OFF 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x27 Auto Screen Adjust 0x00 OFF Yes Yes Disable Enable 0x01 ON 0x30 0x00 OFF Yes Yes Disable Enable 0x01 P amp P 0x02 PinP 0x31 Active Picture 0x00 Left P amp P Main PinP Yes Yes Disable Enable Ox01 Right P amp P Sub PinP 0x02 Swap 0x32 Picture Size P amp P 0x00 0x0E Yes Yes Disable Enable 0x33 Sub Picture Size 0x00 Large Yes Yes Disable Enable PinP 0x01 Small 0x34 Picture Position 0x00 Position1 Yes Yes Disable Enable 0x01 Position2 0x02 Position3 0x03 Position4 0x35 Input Detect 0x08 HD15 RGB No Yes Disable Enable Left Main 0x09 HD15 YUV 0x0E OPTION RGB 0x0F OPTION COMPONENT 0x20 DVI 0x30 VIDEO 0x31 S VIDEO 0x84 Option Digitali HDMI1 SDI 0x85 Option Digital2 HDMI2 0x36 PAP Input Detect 0x08 HD15 RGB No Yes Disable Enable Right Sub 0x09 HD15 YUV 0x0E OPTION RGB 0x0F OPTION COMPONENT 0x20 DVI 0x30 VIDEO 0x31 S VIDEO 0x84 Option Digitali HDMI1 SDI 0x85 Option Digital2 HDMI2 Continued FWD S42H1 Code Table 1 a a Function b Range Switch Cod
28. ia a net work 1 Default Setting Item Description Transport TCP Port number 53484 Factory setting TCP connection time out 30 seconds Factory setting FWD S42H1 33 2 Setting Items The items that can be set to ID Talk are shown in the table below Item Description Start ID Talk Service Select the check box when using ID Talk Clear the check box when using no ID Talk default setting OFF Port No Changes the port number A port number have to change port number 53484 cannot be used because it has been already used for another purpose Timeout Specify the timeout time of connection Connection is automatically disconnected when communication is not done for the specified time IP address of client Executes only the request from the specified IP address Host Address ID Talk does not have the security function such as user authentication During installation safety can be improved by setting this item Multiple host addresses can be set Community Changes the community of a header Four upper or lower case alphanumeric characters can be set default setting SONY Set the items described above properly on the SETUP ID Talk page of the Web page when using ID Talk 3 Packet Structure The packet structure of ID Talk is described below Community Command Data 4 4 n Header 2 Packet structure 3 1 Header The header is constituted by two byt
29. ing be sure to click the Set to List button and then click the Apply button FWD S42H1 29 Editing of Community 1 Select the Community you want to edit from a drop down list 2 Click the button The Community name Rights and Trap destinations text boxes and and buttons are validated Edit the Community name when you want to edit a Community name 3 Setthe Rights of Community and the Trap destinations you want to edit Click the button when you want to discard the setting during setting When you want to save the setting click the Set to List button and then click the button at the bottom of the window Removal of Community 1 Select the Community you want to remove from a drop down list 2 Click the button and then click the Apply button at the bottom of the window Be sure to click the Remove button and then click the button 4 2 Authentication Trap An authentication trap is the trap for making it detect by an SNMP manager that an illegal access was gained to this unit using an SNMP protocol The authentication trap is validated when this check box is selected A trap is transmitted when an illegal access is gained The authentication trap is invalidated when this check box is not selected A trap is not transmitted even if an illegal access is gained Be sure to click the button when you edited setting 4 3 IP Restriction of Host It is possible to put restrictions o
30. ipment transmits MIB information to an SNMP manager via this SNMP agent This unit installs this SNMP agent This unit can realize the communication with a general purpose SNMP manager using this SNMP agent Basically an SNMP agent replies only when an inquiry is sent from an SNMP manager The SNMP manager periodically inquires the equipment which it manages about MIB information This way to get information is called polling In polling equipment replies using a response command when an SNMP manger sends a request command to equipment By polling therefore equipment can be monitored without applying a high load to the equipment On the other hand notification can also be done from the equipment side to an SNMP manager This noti fication is called a trap Using this trap when a serious trouble occurred in equipment it can be notified to the SNMP manager in a short time This unit is compatible with the two polling and trap protocols described above Equipment can be efficiently monitored using these protocols FWD S42H1 27 2 Specifications of SNMP Installation The specifications of the SNMP agent installed in this unit are shown in below SNMP version SNMPv1 MIB definition SMIv2 Support PDU GetRequesat SetRequest GetNextRequest Trap Standard MIB to be installed MIB II 3 Installation The setting below is required to use the SNMP function of this unit Set according to your network environment
31. m Enquiry 0x70 0x00 Code Table Upper 8bit Data Lower 8bit Data OxXX Completed 4 k Return Data1 Data2 0x0000 0xFFFF BCD Format ex In Version0 100 it is set to 01 and 00 Code Table 4 k Function Return Data 0x03 Main CPU 0x0000 0xFFFF OxOF LAN 0x0000 0xFFFF e 8bits Register Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 Code Table 4 b OxFF OxFF OxXX Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 4 b OxXX Completed Code Table 4 b Function Return Data Unit 0x07 Digital 3 3 V 0x00 0xFF 0x08 Analog 24 V 0x00 0xFF For function 0x07 0x08 0x09 0x11 0x12 0x13 0x09 Digital 5 V 0x00 0xFF 0x14 and 0x16 in the left table Ox0A Tempi When the display value is 3 0 V Ox1E 30 is 0x0B Temp2 returned Ox0D Inverter Alarm 0 Normal 1 Abnormal For function 0x0A 0x0B and 0x0D in the left table 0 11 Shutdown Log 0x00 0xFF When the display value is 50 C 0x32 50 is 0x12 Digital 3 3 V Failure 0x00 0xFF returned Digital 5 0x00 0xFF When the display value is 20 C is re 0x14 Analog 12 V Failure 0 00 0 turned 0x16 Analog 12 V 0x00 0xFF FWD S42H1 21 f Shutdown Log Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x11 OxFF OxFF 0xC2 Answer Header Answ
32. ms or more when transmitting the same command Enquiry after the Control command FWD S42H1 b Enquiry message No Item Value 1 Header 0x83 Enquiry 2 Category OxXX 3 Function OxXX 4 Data1 OxFF 5 Data2 OxFF 6 Check Sum OxXX Check Sum Sum total of 1 to X lower one byte data is validated when a value exceeds 255 1byte c Answer message Control answer No Item Value 1 Header 0x70 Answer 2 Answer 0x00 Completed 0x01 Limit Over 0x02 Limit Under 0x03 Command Canceled 3 Check Sum OxXX 0x00 Completed Packet is correctly received and process is also correctly completed 0x01 Limit Over Packet is correctly received but the data value is over the upper limit 0x02 Limit Under Packet is correctly received but the data value under the lower limit 0x03 Command Canceled Packet is correctly received but the data value is not correct or the request cannot be accepted in the current host state Check Sum Sum total of 1 to X lower one byte data is validated when a value exceeds 255 1byte Enquiry answer Complete No Item Value 1 Header 0x70 Answer 2 Answer 0x00 Completed 3 Return Data Size OxXX 4 Return Data1 OxXX OxXX X Return DataX OxXX X 1 Check Sum OxXX 0x00 Completed Packet is correctly received and process is also correctly completed Return Data Returns the read value Check Sum Sum total of 1 to X lower one
33. n Data1 Data2 Data3 Check Sum Control 0x8C 0x00 0x22 0x03 Hour 0x00 0x17 Minute 0x00 0x3B Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x22 OxFF OxFF 0 Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70 0x00 0x03 Hour 0x00 0x17 Minute 0x00 0x3B Completed Clock Set Week Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x23 OxFF OxFF 0 4 Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Week Code Table 1 e OxXX Completed 10 FWD S42H1 Code Table 1 e Week Select 0x00 Sunday 0x01 Monday 0x02 Tuesday 0x03 Wednesday 0x04 Thursday 0x05 Friday 0x06 Saturday On Timer Off Timer Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x00 Code Table 1 f a 0x03 Hour 0x00 0x17 Minute 0 00 0 38 Syntax Header Category Function Data1 Enquiry 0x83 0x00 Code Table 1 f a OxFF Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70 0x00
34. n the IP address of an SNMP manager as one of the security countermea sures which communicates using an SNMP protocol P address restriction is invalidated when you select Accept packets from any host Only the SNMP access from an SNMP manager that has the set IP address is accepted when you select Accept packets from those hosts The SNMP access from an IP address that has not been set is reject ed Up to four IP restrictions can be set Be sure to click the button when you edited setting 30 FWD S42H1 5 MIB to Be Installed This unit installs MIB 2 MIB 2 is the most representative standard MIB It is installed in various network products The statistical information on the amount of network traffic or the number of transmitted and received packets is defined and the change or transition can be monitored by polling the information periodically Additionally the management items to be installed can be defined using a TCP IP device so as to get the information effective for the monitoring of the network communication state Refer to RFC1213 for the detailed definition of MIB 2 6 Information to Be Notified on Trap In software version 2 0 or later the software have a function that transmits error information to this unit The error trap and authentication trap are installed FWD S42H1 31 Section 3 ID Talk ID Talk is set as described below ID Talk is a protocol for operating the function of this unit v
35. nal Detect becomes Disable When Option Slot is connected Option command is Enable FWD S42H1 19 9 Status Enquiry a Model Name Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x00 OxFF OxFF 0 1 Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table 4 a OxXX Completed Code Table 4 a Format Select 0x28 FWD S42H1 0x29 FWD S47H1 b Serial Number Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x01 OxFF OxFF OxB2 Answer Header Answer Return to Return Data1 Return Data2 Return Data3 Return Data4 Check Sum Data Size Enquiry 0x70 0x00 0x05 Upper 8bit Middle Upper Middle Lower Lower 8bit OxXX Completed Data Data Data Data Return Data1 Data4 0x00000000 0x0098967F 0 000 000 9 999 999 c Operation Time Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x02 OxFF OxFF 0xB3 Answer Header Answer Returnto Return Datal Return Data2 Return Data3 Return Data4 Check Sum Data Size Enquiry 0x70 0x00 0x05 Upper 8bit Middle Upper Middle Lower Lower 8bit OxXX Completed Data Data Data Data Return Data1 Data4 0x00000000 0xD693A3FF 0sec 3 599 999 99sec 20 FWD S42H1 d Soft Version Main CPU LAN Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 Code Table OxFF OxFF OxB4 4 9 Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Su
36. uiry 0x70 0x00 0x02 Code Table 2 b 0xFF OxXX Completed Code Table 2 a a Function b Range Switch Code Command Control Enquiry Standby Power On 0x77 Priority Signal Select 0x00 Inputl Auto No Yes Disable Enable Ox01 Input RGB 0x02 Inputi YPbPr Code Table 2 d Input Select 0x00 HD15 0x01 Option b Time Control Data Set Month Date Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x00 0 7 0x03 Month 0x01 0x0C Date 0x01 0x1F Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0 7 OxFF OxFF OxFD Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70 0x00 0x03 Month 0x00 0x0C Date 0x01 0x1F Completed FWD S42H1 Year Set Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x00 0x7B 0x02 Year 0x00 0x63 OxXX Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x7B OxFF OxFF OxFC Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 Ox71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Year 0x00 0x63 0xXX Completed Clock Set Hour Minute Syntax Header Category Functio
37. well as an ID Talk protocol Use a SET command in this case Also use a SET command when receiving information from the display equipment 4 2 Responses A response returns the result of execution to the request from a host Response Contents NG 00h Indicates that a request is invalid or could not be executed OK 01h Indicates that a request could be executed normally 4 3 SET request The SET request sets a new value to the specified item A request and its response are described in details below Request Data Request Item No F Length Data 00h Item No n Set Data n byte SET request Response OK 01h Item No n Get Data n byte Response to SET request 4 4 GET request The GET request gets the value of the specified item A request and its response are described in details below Request Data Request Item No Length Oth Item No 0 GET request Response OK 01h Item No n Get Data n byte Response to GET request 36 FWD S42H1 4 5 ERROR response An NG message is returned as a response when an error occurs in the contents of a request or the result of execution NG 00h Item No 2 Error Code 16 ERROR response 5 Items Category Contents SET GET 80sckh Gets the information of this unit O O 90h Gets the network setting information O F100h FWD S42H1 S47H1 dedicated protocol O _ 5 1 80 h This item gets the inform

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - アイコム  Buffalo AirStation WHR-G300NV2/U  User manual ()  "取扱説明書"  Manual - Optimus  Análise Funcional em Processos de Produção Lean  Weider C520 User's Manual  RL-200 1S Manual - Survey Equipment  ASRock IMB-A160 Owner's Manual  Toulouse et ses environs - Immobilier Neuf Mode d`Emploi  

Copyright © All rights reserved.
Failed to retrieve file