Home

Monte Carlo Fan Company 5HS42 Series User's Manual

image

Contents

1. 15 Flush Mount Installation Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the eguipment grounding conductor on one the canopy side of the outlet box and ungrounded conductor on the other side of the outlet box Pass leadwires and safety cable through Hands free hook Place cano zer yoke to pass through the large hole in the center Hang fan from mounting bracket by of the canopy Align the 3 larger holes around the the hands free hook into a closed center hole with the 3 screws already installed in hole on the edge of the Canopy the fan Install 3 flush mount screws provided into Note For Canadian mounting refer to smaller holes and tighten securely Step 8 Remove the screws from the side panel corresponding to the closed holes on the canopy upper rim Keep these screws for later use Remove the all thread studs from the lower part of the mounting bracket Install blades to motor using the 10 motor screws provided Tighten screws securely Lift fan to mounting bracket aligning the L shape holes with the scresws on the mount ing bracket Turn the fan clockwise to lock in position Re install the screws removed in the previous step and tighten securely Place blade holders onto blades aligning holes in blade holder with holes in blade
2. Make sure that the side of the blade you select is facing downward Install 3 screws and fiber wash ers to back side of blade as shown Tighten screws securely Repeat this process 4 more times until all blades are assembled TROUBLE SHOOTING If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work be locked securely fasten a prominent warning device such as a tag to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 3 Make sure forward reverse switch is firmly in up or down position Fan will not operate when switch is in the middle 4 Make sure that shipping stabilizer tabs have
3. been removed from motor see installation step 13 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 If using an optional Ceiling Fan Light Kit check to be sure the screws securing the glassware are finger tight Check to be sure light bulb is tight in socket and not touching glass shade s If vibra tion persists from glass remove glass and install a 1 4 wide rubber band on glass neck to act as an insulator Replace glass and tighten screws against rubber band 5 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball See illustration in Step 6 of Downrod Mount installation 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceili
4. outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion
5. OWNER S MANUAL Ceiling Fan Installation Instructions Total fan weight UE For 5HS42 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Wi QUALITY CEILING FANS LISTED Tread leadwires and safety cable first through the canopy disk Canopy and Body Align the hole in the Downrod with the once the downrod is in place lastly downrod hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on the other side Install the Keeper Pin Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con ductor on one side of the outlet box and ungrounded conductor on the other side of the
6. airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to outlet box ensure the outlet box is securley fas tened by at least two points to a structural ceil ing member a loose box will cause the fan to wabble Use only the screws provided with the outlet box Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Insert downrod into yoke on top of the Fan Tighten the 2 Set screws on the Yoke Hang assembled fan from the moun
7. ng joist 5 Most fan wobble problems are caused when blade levels are unegual Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not egual you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the posi tion of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistrib ute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 1 800 519 4092
8. ting bracket installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual U Remove side covers from canopy expos ing 4 holes 2 closed holes and 2 open L shape holes Canadian mounting only y For Canadian installation in both flush and down rod mode the safety cable must be installed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires Remove all 4 screws from Mounting bracket These screws will not be needed for Downrod Mode installation Cover Ring Lift Conopy allowing the 2 studs to Next lift the cover ring and install knurled protrude through the canopy nuts as shown Tighten the knurled nuts securely The canopy should adjust for ad irregularity in the ceiling or Outlet ox