Home

La Crosse Technology WS-7394U-IT User's Manual

image

Contents

1. WS 7013U IT Wireless 915 MHz Temperature Station Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents Quick Setup Detailed Setup Guide Battery Installation Setting the Time Features Minimum and Maximum Temperatures Resetting Minimum and Maximum Temperatures Additional remote temperature sensors optional Mounting Troubleshooting Maintenance and Care Specifications Warranty Information This product offers INSTANT TRANSMISSION INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update every 4 seconds of all your outdoor data measured from the sensors follow your climatic variations in real time INVENTORY OF CONTENTS 1 The indoor temperature station Figure 1 2 The remote temperature sensor TX29U IT and mounting bracket Figure 2 3 each 1 2 Philips screws One strip of double sided adhesive tape Instruction Manual and Warranty Card aro Fi 1 SAS Figure 2 PH i dls l ki ADDITIONAL EQUIPMENT not included 1 1 Philips screwdriver 2 2 Fresh AAA 1 5V batteries 3 2 Fresh AA 1 5V batteries QUICK SETUP Hint Use good quality Alkaline Batteries and avoid rechargeable batteries 1 Have the indoor temperature station and remote temperature sensor 3 to 5 feet apart 2 Batteries should be out of
2. M N MAX button for four seconds MOUNTING Note To achieve a true temperature reading avoid mounting in direct sunlight We recommend that you mount the remote temperature sensor on an outside North facing wall The sending range is 330ft obstacles such as walls concrete and large metal objects will reduce the range Place both units in their desired location before permanently mounting 1 REMOTE TEMPERATURE SENSOR Free standing Simply attached the stand to the bottom of the unit and place onto a flat surface M li To wall mount a Remove the mounting bracket from the temperature sensor t WW 17 b Mount using either screws or adhesive tape c Reattach the temperature sensor to the mounting bracket 2 THE TEMPERATURE STATION e The indoor temperature station comes with the table stand already mounted If you wish to use the table stand all that is required is to place the indoor temperature station in an appropriate location f To wall mount remove the table stand To do this pull down on the stand from the rear and rotate forward Fix a screw not included into the desired wall and place the indoor temperature station onto the screw using the hanging hole on the backside Gently pull the indoor temperature station down to lock the screw into place TROUBLESHOOTING NOTE For problems not solved please contact La Crosse Technology via e mail or phone or visit our websit
3. 2 4 q display and a number will flash next to are it Press and release the SET button ira l eight more times to advance to the Li i Manual Month setting The Month will begin to flash below the time display Press and release the OUT button to select the desired month Press and release the SET button to confirm the month and continue to the Date setting K Setting The Date Manually 1 2 Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it 11 DV e 2 l 2 N Relative Pressure Setting 1 2 Press and release the SET button nine more times to advance to the Manual Date setting The date will begin to flash below the time display Press and release the OUTA button to select the desired date Press and release the SET button to confirm the date and continue to the Temperature Measuring Units setting Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it Press and release the SET button ten more times to advance to the Temperature Measuring Units setting r F or C will flash at the top of the display Press and release the OUT button to select the desired temperature measuring unit Temperature Measuring Units Selection F or C 1 TIME D WWV
4. Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse 21 Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship
5. Ls ILI Hour setting ear os The hour will begin to flash at the top of the display Press and release the OUT button to select the desired hour Press and release the SET button to confirm the hour setting and continue to the Minute setting 10 H tars The Minutes Manually k Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it Press and release the SET button six more times to advance to the Manual Minutes setting The minutes will begin to flash at the top of the display Press and release the OUT button to select the desired minutes Press and release the SET button to confirm the minutes and continue to the Year setting I a The Year Manually Press and hold the SET button for five seconds TE ewe Icd will appear at the top of the Pm q display and a number will flash next to j it DATE Press and release the SET button e00 E Hi 4 seven more times to advance to the Manual Year setting The year will begin to flash below the time display Press and release the OUT button to select the desired year Press and release the SET button to confirm the year and continue to the Month setting J Setting The Month Manually 1 2 De Press and hold the SET button for TIME we five seconds i Icd will appear at the top of the i
6. below the time display Press and release the OUT button to select the desired time zone Press and release the SET button to confirm the Time Zone setting and continue to the DST ON OFF setting D DST ON OFF Setting 1 2 4 5 Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to 1t Press and release the SET button twice more to advance to the DST ON OFF setting TIME DST WWVB mm List He DST will appear above the indoor temperature humidity display and ON or OFF will flash above that Press and release the OUT button to select DST ON OFF Note Some locations Arizona and parts of Indiana do not follow Daylight Saving Time 6 Press and release the SET button to confirm the DST ON OFF setting and continue to the radio controlled Time ON OFF setting E Radio Controlled Time ON OFF Setting 1 2 Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it Press and release the SET button three more times to advance to the radio controlled time ON OFF setting TIME RCC will appear above the indoor temperature humidity display and ON or OFF will flash above that Press and release the OUT button to select radio
7. controlled time ON OFF setting Press and release the SET button to confirm the radio controlled time ON OFF setting and continue to the 12 24 hour Time Mode setting F 12 24 hour Time Mode l 2 Press and hold the SET button for ere Q Wia five seconds Icd will appear at the top of the f Co J u display and a number will flash next to l it Press and release the SET button four a h 3 more times to advance to the 12 24 hour time mode setting 12h or 24h will flash above the indoor temperature humidity display Press and release the OUT button to select 12 or 24 hour time mode Note In 12h mode PM will appear to the left of the time during PM hours If the time is not within the PM hours nothing will be displayed Be sure to set the time to the correct AM PM time to ensure automatic reception 6 Press and release the SET button to confirm the 12 24 hour time mode setting and continue to the Hour setting G Setting The Hour Manually The WWVB signal will override any manual set time and date information The time will be based on the time zone selected l 2 Dye Press and hold the SET button for five seconds IM O ae Icd will appear at the top of the f l j 1 display and a number will flash next to LJ z Lj it DATE Uy Press and release the SET button five c bs oF more times to advance to the Manual
8. for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay 23 ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on 24 misrepresentation by the seller or performance variations resulting from installation related circumstanc
9. or start up problems may occur Replace cover B INDOOR TEMPERATURE STATION Note After the batteries are installed DO NOT press any buttons This may interfere with the signals causing temperatures to register incorrectly a Remove the battery cover on the backside To do this push up and pull out Battery Cover b Observing the correct polarity install 2 AAA batteries c Replace battery cover d Wait 15 minutes to allow both the indoor and outdoor temperatures are shown on the indoor temperature station 10 TIME cH a ia i i i5 OUTDOOR t LUA Sensor signal 2 reception icon When the signal is successfully received by the Temperature Station the icon will be switched on If not successful the icon will not be shown in LCD So the user can easily see whether the last reception was successful icon on or not icon off On the other hand the short blinking of the icon shows that a reception is being done now e Ifthe signal reception is not successful on the first frequency 915MHz for 45 seconds the frequency is changed to 920MHz and the learning is tried another 45 seconds If still not successful the reception is tried for 45 seconds on 11 910MHz This will also be done for re synchronization SETTING THE TIME 1 Press and hold the SET CH button for 5 second 12h will appear in the TIME LCD Press and release the MI
10. temperature sensor units with the WS 7013U IT These extra sensors can be purchased through the same dealer as this unit 1 Remove all the batteries from the receiver and sensor s and wait 60 seconds During these 60 seconds press any button 20 times to discharge any excess power Insert the batteries to the first temperature sensor Within 2 minutes of powering up the first sensor insert the batteries to the Temperature Station Once the batteries are in place all segments of the LCD will light up briefly Following the indoor temperature and the time as 12 00 will be displayed If they are not shown in LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them The outdoor temperature from the first sensor channel 1 should then be displayed on the Temperature station If this does not happen and the signal reception icon is not shown after 2 minutes the batteries will need to be removed from both units and reset from step 1 14 Insert the batteries to the second sensor as soon as the outdoor temperature readings from the first sensor are displayed on the Temperature station NOTE You must insert the batteries into the second sensor within 45 seconds of reception of the first sensor The outdoor temperature from the second sensor and the channel 2 icon should then be displayed on the Temperature station If this does not happen after 2 minute the batteries will need
11. to be removed from all the units and reset from step 1 Insert the batteries to the third sensor as soon as the channel 2 icon and outdoor data are displayed on the Temperature station Then within 2 minutes the channel 3 outdoor data from the third sensor will be displayed and the channel icon will shift back to 1 once the third sensor is successfully received If this is not happen user shall restart the setting up from step 1 15 NOTE You must insert the batteries into the third sensor within 45 seconds of reception of the second sensor IMPORTANT Transmission problems will arise if the setting for multiple sensors is not followed as described above Should transmission problems occur it is necessary to remove the batteries from all units and start again the set up from step 1 VIEWING AND OPERATING WITH MULTIPLE REMOTE TEMPERATURE reed UNITS To view the temperature of a different remote temperature sensor unit press and release the SET CH button A shift from one boxed number to the next should be observed in the OUTDOOR LCD 2 To view the Minimum Maximum temperature first select from which remote temperature sensor to read data indicated by the boxed number Pressing and releasing the MIN MAX button will toggle through the minimum and maximum indoor temperature and the minimum and maximum outdoor temperature 16 3 To reset the Minimum Maximum readings press and hold the
12. to program each function separately or you can follow the instructions entirely to program the Wireless Weather Station Complete programming is usually done for the initial set up and will require you to skip step 1 2 and 3 of each programming section The programming mode can be exited at any time by either pressing the CH button or waiting for the 15 second time out to take effect A Overview of programming mode sequence 1 LCD Contrast 2 Time Zone 3 DST ON OFF Radio controlled 5 12 24 hour 6 Hour Time ON OFF time mode 7 Minute 8 Year 9 Month 10 Date 11 F C 12 inHg hPa 13 Relative pressure 14 Forecast setting sensitivity B LCD Contrast Setting 1 Press and hold the SET button for TIME five seconds 2 lcd will appear at the top of the i C d display and a number will flash next to it DATE qY 3 Press and release the OUT G f button to select the desired LCD l contrast setting 4 Press and release the SET button to confirm the LCD contrast setting and continue to the Time Zone setting C Time Zone Setting l 2 Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it Press and release the SET button once more to advance to the Time Zone setting A number will flash to the left of the letter h at the top of the display just
13. with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State S
14. 1 resolution Display if temperature is OL F display if lt 1 and 99 if gt 99 Air pressure Relative hPa adjustable 960 hPa to 1040 hPa Relative inHg adjustable 28 35 inHg to 30 72 inHg Sensitivity setting hPa 2 hPa to 4 hPa Air pressure history For the past 12 hours 0 3 6 9 and 12 hours Data checking intervals Indoor temperature Every 15 second Indoor humidity Every 20 seconds Outdoor temperature Every 4 seconds Sensor reading update within sensor Outdoor temperature Every 4 seconds Transmission frequency 915 MHz Transmission range 330 feet max 100m in open space Power supply Wireless Weather Station 2 x AA IEC LR6 1 5V batteries Remote Temperature Sensor 2 x AA IEC LR6 1 5V batteries Dimensions H x W x D Wireless Weather Station 8 75 x 4 x 1 5 222 x 102 x 38 mm Remote Temperature Sensor 5 05 x 1 50 x 0 83 inches 128 3 x 38 2 x 21 2 mm WARRANTY INFORMATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La
15. AST t e le el lo mo PRESSURE PRESSURE STORY 293 t OUTDOCA a SF gt f 3 503 Sensor signal rece tion icon hen the signal is successfully received by the Weather Station the icon will be switched on If not successful the icon will not be shown in LCD So the user can easily see whether the last reception was successful icon on or not icon off On the other hand the short blinking of the icon shows that a reception is being done now If the signal reception is not successful on the first frequency 915MHz for 45 seconds the frequency is changed to 920MHz and the learning is tried another 45 seconds If still not successful the reception is tried for 45 seconds on 910MHz This will also be done for re synchronization II Start Up Sequence A Initial Start 1 2 Immediately after the batteries have been installed the LCD will completely light up for a brief moment All information will then appear in normal mode with 12 00 as the default time and SA 1 as the default date 2006 as the year The indoor temperature and humidity and barometric air pressure as 29 92 inHg relative RH will also be displayed There is a satellite icon that appears in the bottom portion of the LCD to the left of the outdoor temperature this icon informs the user that th
16. ATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd 22 authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged
17. B OF int Su ii Ld Press and release the SET button to confirm the temperature measuring unit and continue to the Air Pressure Measuring Units setting Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to it Press and release the SET button eleven more times to advance to the Air Pressure Measuring Units setting TIME Air Pressure Measuring Units Selection inHg hPa WWVB im HB E int Ly Ld inHg or hPa will flash at the top of the display Press and release the OUT button to select the desired air pressure measuring unit Press and release the SET button to confirm the air pressure measuring unit and continue to the Relative Pressure setting Press and hold the SET button for five seconds Icd will appear at the top of the display and a number will flash next to 1t 12 ano ae oA PRESSURE eds PRESSURE HISTORY inHg en o gt wo gt 2 gt 12h 6h 3 Press and release the SET button twelve more times to advance to the Relative Pressure setting 4 The barometric air pressure will flash in the middle of the display just below the forecast icon 5 Press and release the OUT or IN button to select the desired relative air pressure value 6 Press and release the SET button to confirm the
18. N MAX button to select either 12h time am pm or 24h time Press and release the SET CH button 2 times the hour will flash in the upper left corner Press and release the MIN MAX button to set the hours Press and release the SET CH button to move to the minute setting Press and release the MIN MAX button to set the minutes Press and release the SET CH button to activate the clock Note When in 12h mode there is only a PM display which appears under TIME If there is no display here it is AM Make sure you set the time accordingly 12 Note if 12h is selected the temperature is displayed in degree Fahrenheit If 24h is selected the temperature is displayed in degree Celsius FEATURES MINIMUM amp MAXIMUM TEMPERATURES 1 Press and release the MIN MAX button MIN appears in the temperature LCD s and the recorded minimum temperatures are displayed 2 Press and release the MIN MAX button to toggle to the maximum temperatures The time of occurrence of the value for outdoor temperature will also flash RESETTING THE MINIMUM amp MAXIMUM TEMPERATURES To reset both the minimum and maximum temperatures press and hold the RESET button for 4 seconds ADDING ADDITIONAL REMOTE SENSORS OPTIONAL The WS 7013U IT is able to receive signals from 2 additional temperature sensors The following are instructions for the set up of 13
19. WS 7394U IT Wireless 915 MHz Wireless Weather Station Instruction Manual ex au 135 48 0 i Tomorrow s Weather Today TABLE OF CONTENTS Topic Page Inventory of Contents Additional Equipment 3 About WWVB 3 Quick Set Up Guide 4 Detailed Set Up Guide Battery Installation 5 Start Up Sequence 6 Explanation of LCD Information 7 Function Key Layout 8 Program Mode Overview of Programming Sequence 8 LCD Contrast Setting 8 Time Zone Setting 9 DST ON OFF Setting 9 Radio controlled Time ON OFF Setting 9 10 12 24 hour Time Mode Setting 10 Setting the Time Date Manually 10 11 Temperature Measuring Units CF C 12 Air Pressure Measuring Units inHg hPa 12 Relative Pressure Setting 12 Forecast Sensitivity Setting 13 Features and Operation Minimum Maximum Temperature Humidity 14 Multiple Remote Temperature Humidity Sensors 15 16 Comfort Icon 16 Weather Forecast and Pressure Trend Indicators 16 Weather Icons 16 17 Weather Tendency Arrows 17 Barometric Air Pressure Reading 17 Air Pressure History Bar Chart 17 18 Mounting 19 20 Maintenance and Care 20 Troubleshooting Guide 21 Specifications 22 Warranty Information 23 24 This product offers ITE ozz INSTANT TRANSMISSION INVENTORY OF CONTENTS INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusi
20. are acknowledged 26 FCC ID OMOTX29U sensor RF Exposure mobile The internal external antennas used for this mobile sensor must provide a separation distance of at least 20 cm 8 inches from all persons and must not be co located or operating in conjunction with any other antenna or sensor Statement according to FCC part 15 19 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Statement according to FCC part 15 21 Modifications not expressly approved by this company could void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful 27 interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh
21. both units for 10 minutes 3 Place the batteries into the remote temperature sensor first then into the indoor temperature station All remote temperature sensors must be started before the indoor temperature station 4 DONOT PRESS ANY BUTTONS FOR 15 MINUTES In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature If the indoor temperature station does not display both temperatures after the 15 minutes please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoors and set your time The remote temperature sensor should be placed in a dry shaded area The thermo hygro sensor has a range of 330 feet Keep in mind that the 330 feet is in open air with no obstructions and that radio waves DO NOT curve around objects Actual transmission range will vary depending on what is in the path of the signal Each obstruction roof walls floors ceilings thick trees etc will effectively cut signal range in half Example A wireless weather station with a 330 feet range is mounted on an interior wall so that the signal has to pass through one interior wall one exterior wall and across the 10 feet width of the room between the 2 walls The first wall will reduce the range to 165 feet and the
22. ction roof walls floors ceilings thick trees etc will effectively cut signal range in half Example A Wireless Weather Station with a 330 feet range is mounted on an interior wall so that the signal has to pass through one interior wall one exterior wall and across the 10 feet width of the room between the 2 walls The first wall will reduce the range to 165 feet and the second wall will reduce the range to 87 feet Factoring in the 10 foot room this leaves a maximum of 77 feet of remaining signal range This allowance is typically enough for a frame wall with non metallic siding however certain materials can reduce range even further Metal siding stucco and some types of glass can reduce signal range by as much as or more compared to the 1 2 reduction typical of most obstructions It is possible to receive a signal through these materials however maximum range will be much less due to their tendency to absorb or reflect a much larger portion of the sensor s signal DETAILED SET UP GUIDE l BATTERY INSTALLATION When one temperature sensor is being used if 2 First insert the batteries to the temperature sensor see A Remote Temperature Sensor below Within 2 minutes of powering up the sensor insert the batteries to the Weather Station see B Wireless Weather Station below Once the batteries are in place all segments of the LCD will light up briefly Following the indoor temperature and humi
23. dity and the time as 12 00 will be displayed If they are not shown in LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them Once the indoor data is displayed user may proceed to the next step After the batteries are inserted the Weather Station will start receiving data signal from the sensor The outdoor temperature should then be displayed on the Weather Station If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 and the signal reception icon is no longer shown Remote Temperature Sensor 1 Remove the mounting bracket The bracket snaps m on and off easily 2 Remove the battery cover by sliding the cover down 3 Observing the correct polarity install 2 AA batteries The batteries will fit tightly to avoid start up problems make sure they do not spring free 4 Replace the battery cover by sliding upwards Be sure battery cover is on securely Battery Cover B Wireless Weather Station 1 Remove the battery cover the cover has white writing on it 2 Observe the correct polarity and install two Alkaline AA batteries 3 Do not press any buttons for at least ten minutes If a button is pressed before the indoor weather station has received information from the TX29U IT sensor no data will be received from that sensor until reset 4 Replace the battery cover D pate FOREC
24. e www lacrossetechnology com 18 Problem The LCD is faint Solution Replace batteries Problem No outdoor temperature displayed Solution 1 Remove all batteries reinsert into remote temperature sensor first and then into the indoor temperature station 2 Place remote temperature sensor closer to the indoor temperature station 3 Be sure all batteries are fresh 4 Place remote temperature sensor and indoor temperature station in position so the straight line signal is not passing through more than two or three walls Problem Temperatures do not match if units are placed next to each other Solution Each temperature sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions so two temperature sensors could be as much as 2 degrees different However the difference can be exaggerated further because the temperature sensors are designed for different working environments 19 The indoor sensor is less responsive to ambient air currents because of the shielding effect of the display s case In addition the case can act as a heat sink to absorb and store heat from external sources i e handling of the case or radiant heat In addition the much greater range of the outdoor temperature sensor requires a different calibration curve than the indoor range Error is usually greater at the extreme ends of a range making it harder to compare different ranges with different cur
25. e PM hours During the AM hours this area will be blank 6 When the correct hour is shown press and release the SET button once Press and release the SET button once more and you are done DETAILED SETUP GUIDE BATTERY INSTALLATION When one Temperature sensor is being used 1 First insert the batteries to the Temperature sensor see A Temperature sensor below Within 2 minutes of powering up the sensor insert the batteries to the Temperature Station see B Indoor Temperature station below Once the batteries are in place all segments of the LCD will light up briefly Following the indoor temperature and the time as 12 00 will be displayed If they are not shown in LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them Once the indoor data is displayed user may proceed to the next step After the batteries are inserted the Temperature Station will start receiving 8 data signal from the sensor The outdoor temperature and humidity should then be displayed on the Temperature Station If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 and the signal reception icon is no longer shown A REMOTE TEMPERATURE SENSOR Remove the mounting bracket Battery a Remove battery cover cover b Observing the correct polarity install 2 AA batteries make sure they do not spring free
26. e forward b Fix ascrew not included into the desired wall leaving approximately 3 16 of an inch 5mm extended from the wall c Place the indoor weather station onto the screw using the hanging hole on the backside d Gently pull the indoor weather station down to lock the screw into place Maintenance and Care Instructions A Extreme temperatures vibration and shock should be avoided to prevent damage to the units B Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings C Do not submerge in water 19 D Immediately remove all low powered batteries to avoid leakage and damage E Opening the casings invalidates the warranty Do not try to repair the unit Contact La Crosse Technology for repairs TROUBLESHOOTING Problem The LCD is faint Solution 1 Set the LCD contrast to a higher level 2 Replace batteries Problem No outdoor temperature is displayed Solution 1 Remove all batteries reinsert into the remote temperature sensor first then into the indoor weather station 2 Place remote temperature sensor closer to the indoor weather station 3 Be sure all batteries are fresh 4 No other interfering sources are being used such as computer monitors TV sets headphones or speakers in the vicinity The signal travels in a straight line an electrical source near that line may cause interf
27. e indoor weather station is looking for signals from the remote temperature sensor Within five minutes the remote temperature should be displayed if not remove batteries from all units and repeat battery installation the remote temperature sensor first then the indoor weather station B WWVB Reception 1 Once the batteries are installed in the Wireless Weather Station it will automatically search for the WWVB signal If it receives a good signal which is unlikely during daylight hours in most locations the WWVB reception indicator looks like a tower icon will flash The Wireless Weather Station requires five full minutes of good reception to successfully capture the signal and set to the correct hour minute second month day and year If the signal reception is not successful within ten minutes the signal search will be cancelled Next reception will take place the next day The signal is sent from Ft Collins Colorado only and is similar to an AM radio signal Atmospheric interferences such as storms sunspots and even sunlight will cause the signal to not travel as far To maximize reception place the Wireless Weather Station n in a window facing Colorado at least six feet from any electrical source computers televisions refrigerators etc Do not move the indoor weather station while it is searching for the signal 6 4 The time and date can be manually set Once the signal is captured it will override any ti
28. en be displayed on the Weather Station If this does not happen and the signal reception icon is not shown after 2 minutes the batteries will need to be removed from both units and reset from step 1 Insert the batteries to the second sensor as soon as the outdoor temperature readings from the first sensor are displayed on the Weather Station NOTE You must insert the batteries into the second sensor within 10 seconds of reception of the first sensor The outdoor temperature from the second sensor and the channel 2 icon should then be displayed on the Weather Station If this does not happen after 2 minute the batteries will need to be removed from all the units and reset from step 1 Insert the batteries to the third sensor as soon as the channel 2 icon and outdoor data are displayed on the Weather Station Then within 2 minutes the channel 3 outdoor data from the third sensor will be displayed and the channel icon will shift back to 1 once the third sensor is successfully received If this is not happen user shall restart the setting up from step 1 NOTE You must insert the batteries into the third sensor within 10 seconds of reception of the second sensor IMPORTANT Transmission problems will arise if the setting for multiple sensors is not followed as described above Should transmission problems occur it is necessary to remove the batteries from all units and start again the set up from step 1 C Viewing and Operating wit
29. erence Problem Temperature humidity or air pressure is incorrect Solution 1 Check Replace batteries 2 If multiple remote sensors are in use check location with corresponding boxed numbers 3 Move away from sources of heat cold 4 Adjust relative air pressure to a value from a reliable source TV radio etc 5 The indoor weather station and remote sensors are calibrated at the factory If there is a consistent problem please call La Crosse Technology Problem in humidity display Solution 1 Humidity is below 1 Problem WWVB time and date will not set or update Solution 1 Wait until overnight for signal to be received 2 Move indoor weather station away from sources of electricity 3 Place indoor weather station in window facing Colorado 4 The first reception is most difficult as the indoor weather station needs five continual minutes of clear signal reception After the initial time date set the indoor weather station only requires one full minute of clear reception each night SPECIFICATIONS Temperature measuring range Indoor 14 2 F to 139 8 F with 0 2 F resolution 9 9 C to 59 9 C with 0 1 C resolution OFL displayed if outside this range 20 Outdoor 39 8 F to 139 8 F with 0 2 F resolution 39 9 C to 59 9 C with 0 1 C resolution OFL displayed if outside this range Relative humidity range Indoor 1 to 99 with
30. es LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 25 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com Questions Instructions Please visit www lacrossetechnology com 7013 All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents
31. face with a pencil t EAS D d Screw mounting bracket onto the mounting surface Hs Ensure that the screws are flush with the bracket a e Insert the remote temperature sensor into the bracket 2 2 MOUNTING WITH ADHESIVE TAPE 18 a With a nonabrasive solution clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold The mounting surface should be smooth and flat Remove the protective strip from one side of the tape c Adhere the tape to the designated area on the back of the mounting bracket d Remove the protective strip from the other side of the tape e Position the remote temperature sensor in the desired location ensuring that the Wireless Weather Station can receive the signal Note Mounting with adhesive tape is not recommended as a permanent mounting solution Only use the adhesive tape during set up process B Mounting the WS 7394U IT Wireless Weather Station The Wireless Weather Station can be mounted in two ways e with the table stand e on the wall with the use of a wall hanging screw not included 1 USING THE TABLE STAND The indoor weather station comes with the table stand already mounted If you wish to use the table stand all that is required is to place the indoor weather station in an appropriate location 2 WALL MOUNTING a Remove the table stand To do this pull down on the stand from the rear and rotat
32. g down indicates that the air pressure is decreasing and the weather is expected to become worse or remain Weather Tendency Arrows left side of the LCD and one that 4 An arrow pointing up indicates that the air pressure is increasing poor Barometric Air Pressure Reading 1 The actual barometric air pressure is displayed directly under the weather forecast icon 2 The relative air pressure is calibrated by the user through the programming mode 3 Please Follow the programming instructions in section F of the Detailed Set Up Guide to set this feature Air Pressure History Bar Chart 1 The bar chart indicates the air pressure history trend over the last 12 hours in 5 steps Oh 3h 6h 9h and 12h 2 The Oh represents the current full hour air pressure recording 3 The columns represent the hPa 0 2 4 at specific time 4 The 0 in the middle of this scale is equal to the current pressure and each change 2 4 represents how high or low in hPa the past pressure was compared to the current pressure 5 If the bars are rising the weather is getting better due to the increase of air pressure 6 If the bars go down the air pressure has dropped and the weather is expected to get worse from the present time Oh 17 Note For accurate barometric pressure trends the Weather Station should operate at the same altitude for example it should not be moved from the ground to the second fl
33. h Multiple Remote Sensors a To view the temperature of a different remote sensor press and release the CH button A shift from one boxed number to the next should be observed in the OUTDOOR LCD 15 b The minimum and maximum temperature of the additional remote sensor can be displayed by pressing the OUT button c Toreset the minimum and maximum temperature readings press and hold the SET button for 3 seconds and that temperature record for that remote sensor will be reset only Each remote sensor will have its own minimum and maximum values stored D Comfort Indicator for Indoor Temperature and Humidity 1 The comfort level indicator appears inbetween the indoor tempearture and humidity 2 The indicator will display a happy face when the temperature is between 68 F and 79 F 20 C and 25 9 C and the humidity is between 45 and 65 3 A sad face will be displayed when the temperature and humidity are outside the mentioned ranges E Weather Forecast Icon and Pressure Trend Indicators The weather forecasting feature is estimated to be 75 accurate and is based solely upon the change of air pressure over time The WS 7394U IT averages past air pressure readings to provide an accurate forecast creating a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to a
34. ich can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 28
35. ing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Statement according to FCC part 15 21 Modifications not expressly approved by this company could void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 23
36. ing a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum For more information about WWVB please see the NIST website at http www boulder nist gov timefreg stations wwvb htm QUICK SET UP GUIDE Hint Use good quality Alkaline Batteries and avoid rechargeable batteries 1 Have the Wireless Weather Station and remote temperature sensor 3 to 5 feet apart 2 Batteries should be out of both units for 10 minutes 3 Place the batteries into the remote temperature sensor first then Wireless Weather Station All remote temperature sensors must be started before the Wireless Weather Station 4 DO NOT PRESS ANY BUTTONS FOR 15 MINUTES In this time the Wireless Weather Station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and humidity and an outdoor temperature If the Wireless Weather Station does not display both temperatures after the 15 minutes please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoor and set your time The remote temperature sensor should be placed in a dry shaded area The temperature sensor has a range of 330 feet Keep in mind that the 330 feet is in open air with no obstructions and that radio waves DO NOT curve around objects Actual transmission range will vary depending on what is in the path of the signal Each obstru
37. me and date set to the time zone selected 5 Once the time and date are set the Wireless Weather Station will conduct a search every night at midnight and correct to the accurate time and date Daylight Saving Time is automatic If the signal has been received in the past 24 hours the reception indicator will be displayed After a successful reception no more reception attempt would be made until the following day II Explanation of LCD Information A The below picture highlights the LCD features WW VB Reception Indicator Date Display Comfort Icon Indoor Temperature Humidity Display Air Pressure Trend Indicator Forecast Icon Barometric Air Pressure 12 hour Air Pressure History Outdoor Temperature Display Satellite icon indicates outdoor transmission Radio controlled time 2 44 DATE Su IO HUMIDITY FORECAST PRESSURE edd i PRESSURE HISTORY a A ee E a n a eee 12h 9h 6h OUTDOOR oF Remote Sensor G n Number Up to J B J 3 Total B There are many different modes the indoor weather station can be set to The LCD shown is the normal operating mode and your actual data shown will be different based on your local settings and conditions IV Function Key Layout A The below picture shows the four function keys used in programming and operation of your indoor weather station V Program Mode The program mode is laid out in a manner that allows you
38. nother floor In areas where the weather is not affected by the change of air pressure this feature will be less accurate 1 Weather Icons There are 3 possible weather icons that will be displayed at various times in the center of the indoor weather station LE t as o a Sunny indicates that the weather is expected to improve not that the weather will be sunny b Sun with Clouds indicates that the weather is expected to be fair not that the weather will be sunny with clouds c Clouds with Rain indicates that the weather is expected to get worse not that the weather will be rainy 1 The weather icons change when the unit detects a change in air pressure 16 2 The icons change in order from sunny to sun with clouds to clouds with rain or the reverse 3 It will not change from sunny directly to clouds with rain although it is possible for the change to occur quickly 4 Ifthe symbols do not change the weather has not changed or the change has been slow and gradual 5 The sensitivity of the change in foreacst icon is set by the user in section F of the Detailed Set Up Guide 1 Along with the forecast icon there arrow is a pressure tendency arrow 2 There is one that points up on the nN J points down on the right side of the LCD 3 These arrows reflect current changes in the air pressure and the weather is expected to improve or remain good 5 An arrow pointin
39. ome States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com Questions Instructions Please visit www lacrossetechnology com 7394it All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged 22 FCC ID OMOTX29U sensor RF Exposure mobile The internal external antennas used for this mobile sensor must provide a separation distance of at least 20 cm 8 inches from all persons and must not be co located or operating in conjunction with any other antenna or sensor Statement according to FCC part 15 19 This device complies with Part 15 of the FCC Rules Operation is subject to the follow
40. oor of the house Should the unit be moved to a new location discard readings for the next 48 60 hours This feature cannot be turned off VII MOUNTING Note Before permanently mounting ensure that the Wireless Weather Station is able to receive signals from the sensors and WWVB signal at the desired location To achieve a true temperature reading avoid mounting the remote temperature sensor or any sensor where direct sunlight can reach the remote sensor We recommend that you mount the remote sensor on a North facing wall or under an eve The sending range of the remote temperature sensor is 330 ft 100m however obstacles such as walls concrete and large metal objects can reduce the range Place all units in their desired location and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception If the Wireless Weather Station loses the signal from the remote sensor it will display the last temperature reading for 15 minutes After 15 minutes of not receiving any signals the remote temperature will display A Mounting the Remote Temperature Sensor The remote temperature sensor can be mounted in two ways e with the use of screws e using the adhesive tape T J 1 MOUNTING WITH SCREWS Remove the mounting bracket from the remote temperature sensor i Place the mounting bracket over the desired location i c Through the three screw holes of the bracket mark l the mounting sur
41. relative pressure setting and continue to the Forecast Sensitivity setting Forecast Sensitivity Setting 1 Press and hold the SET button for five seconds 2 lcd will appear at the top of the display and a number will flash next to 1t 3 Press and release the SET button thirteen more times to advance to the Forecast sensitivity setting 4 The two air pressure tendency arrows will begin flashing on either side of the forecast icon and a flashing number will appear under the forecast icon FORECAST af Vv PRESSURE J PRESSURE HISTORY 5 Press and release the OUT button to select the desired forecast sensitivity setting Note Barometric air pressure is usually reported as relative air pressure This reading is based on the combination of absolute air pressure and altitude In general an increase in altitude will result in a decrease in air pressure Relative air pressure will make readings in nearby locations relative to each other to allow for proper forecasting The absolute air pressure reading in the Weather Center cannot be calibrated only the relative air pressure 6 Press and release the SET button to confirm the forecast sensitivity setting THE MANUAL SETTING IS NOW COMPLETED 13 FEATURES AND OPERATIONS A Minimum and Maximum Temperature and Humidity 1 Indoor Minimum and Maximum Temperature and Humidity The indoor weather station automatically stores
42. second wall will reduce the range to 87 feet Factoring in the 10 foot room this leaves a maximum of 77 feet of remaining signal range This allowance is typically enough for a frame wall with non metallic siding however certain materials can reduce range even further Metal siding stucco and some types of glass can reduce signal range by as much as or more compared to the 1 2 reduction typical of most obstructions It is possible to receive a signal through these materials however maximum range will be much less due to their tendency to absorb or reflect a much larger portion of the sensor s signal To complete the set up of your indoor temperature station after the 15 minutes have passed please follow the steps below 1 Press and hold the SET CH button for 5 seconds Note A 12h or 24h will appear on the top line 12h for AM PM 24h for military time To change between 12h and 24h press and release the MIN MAX button When you have your choice shown on the display press and release the SET CH button once Note if 12h is selected the temperature is displayed in degree Fahrenheit If 24h is selected the temperature is displayed in degree Celsius 4 5 An hour will now be flashing Press and release the MIN MAX button until the correct hour is shown Note When in the 12h mode there is PM displayed under the word TIME when in th
43. tdoor minimum temperature c Press and release the OUT key again to return to the normal mode timeout of viewing minimum maximum values will occur if no keys are pressed for fifteen seconds 14 Note To reset the outdoor minimum and maximum temperature first display the values you wish to reset minimum or maximum Next press and hold the SET key for at least three seconds You will see then that the values will reset to the current temperature and corresponding time B Multiple Remote Temperature Sensors The WS 7394U IT is able to receive signals from 2 additional temperature sensors The following are instructions for the set up of temperature sensor units with the WS 7394U IT These extra sensors can be purchased through the same dealer as this unit 1 Remove all the batteries from the receiver and sensor s and wait 60 seconds During these 60 seconds press any button 20 times to discharge any excess power Insert the batteries to the first temperature sensor Within 2 minutes of powering up the first sensor insert the batteries to the Weather Station Once the batteries are in place all segments of the LCD will light up briefly Following the indoor temperature and humidity and the time as 12 00 will be displayed If they are not shown in LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them The outdoor temperature from the first sensor channel 1 should th
44. the minimum and maximum indoor temperature and humidity The minimum and maximum values are updated automatically when a new minimum or maximum is recorded or until manually reset a From the normal display mode press and release the IN key once to view the indoor maximum temperature and humidity MAX will be displayed above the indoor temperature and humidity b Press and release the JN key again to view the indoor minimum temperature and humidity c Press and release the JN key again to return to the normal mode timeout of viewing minimum maximum values will occur if no keys are pressed for fifteen seconds Note To reset the indoor minimum and maximum temperature and humidity first display the values you wish to reset minimum or maximum Next press and hold the SET key for at least three seconds You will see then that the values will reset to the current temperature and humidity and corresponding time 2 Outdoor Minimum and Maximum Temperature The indoor weather station automatically stores the minimum and maximum outdoor temperature The minimum and maximum values are updated automatically when a new minimum or maximum is recorded or until manually reset a From the normal display mode press and release the OUT key once to view the outdoor maximum temperature MAX will be displayed above the outdoor temperature b Press and release the OUT key again to view the ou
45. vely designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update every 4 seconds of all your outdoor data measured from the sensors follow your climatic variations in real time 1 WS 7394U IT Wireless Weather Station Figure 1 2 TX29U IT remote temperature sensor figure 2 3 Instruction manual and warranty card Figure 1 Mounting TX29U IT remote Bracket temperature sensor Figure 2 ADDITIONAL EQUIPMENT not included 1 Five fresh AA 1 5V alkaline batteries 2 One wall mounting screw optional ABOUT WWVB radio controlled time The NIST National Institute of Standards and Technology Time and Frequency Division radio station WWVB is located in Ft Collins Colorado and transmits the exact time signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Wireless Weather Station However due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The Wireless Weather Station will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic clock in Boulder Colorado A team of atomic physicists continually measure every second of every day to an accuracy of ten billionths of a second a day These physicists have created an international standard measur
46. ves Under non laboratory conditions it is difficult to compensate for the above factors and obtain an accurate comparison MAINTENANCE AND CARE v Extreme temperatures vibration and shock should be avoided to prevent damage to the units v Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings v Do not submerge in water v Do not subject the units to unnecessary heat or cold by placing them in the oven or freezer 20 v Opening the casings invalidates the warranty Do not try to repair the unit Contact La Crosse Technology for repairs SPECIFICATIONS Transmitting Frequency Measuring Temperatures Indoor 14 1 F to 139 8 2 F with Temperature 0 2 F resolution Station Indoor 9 9 C to 59 8 C with 0 1 C resolution Indoor 39 8 F to 139 8 F with Temperature 0 2 F resolution Station Outdoor 39 8 C to 59 8 C with 0 1 C resolution Transmitting Up to 330 feet open Temperature check Indoor Every 15 seconds Outdoor Every 4 seconds Batteries Alkaline recommended Remote 2 x AA 1 5V Temperature Sensor 21 Indoor 2 x AAA 1 5V Temperature Station Dimensions H x W x D Indoor 4 3 x 2 75 x 92 in Temperature excluding table stand Station 110 x 90 x 23 6 x mm Remote 5 05 x 1 50 x 0 83 in Temperature 128 3 x 38 2 x 21 2 mm Sensor Battery life Approximately 24 months WARRANTY INFORM

Download Pdf Manuals

image

Related Search

Related Contents

Emerson CS400 Drawings & Schematics  l6.2.5 Programmstart und Audio-Alarm  NPort 5100A Series Users Manual  VS-DVR - Visual Tools    User Manual MMS 20100729  日本ビクター「環境経営報告書 2007」 - JVC Corporate profile  RemoteCom - RESoluCOM  BENDIX 03-A-18 User's Manual  Samsung PS50A552S1R User Manual  

Copyright © All rights reserved.
Failed to retrieve file