Home

JVC Switch K3-R User's Manual

image

Contents

1. K3 1RU AB Switch Page 5 Control Modules The K3 Series AB Switch System is available with three types of control modules Network Contact Closure or Gang Control Expansion One of three control options shown below will be installed in the chassis for remote control of the installed AB switch cards C AB 16 R C AB 16 R provides remote control through In Band and Out of Band operation thru Ethernet TCP IP and Serial connections Through a web browser interface you can access the control card obtain WER current status information and operate the A B Switches Through a telnet client you can access the control card obtain current status information and operate the A B Switches This is also the method for setting configuration parameters of the card Telnet The system can be managed by SNMP through standard management SNMP software Dataprobe provides a private MIB The serial port on the C AB 16 R provides direct terminal access or via modem The A B Cards are controlled either by a menu selection or by command line strings escape code sequences Menu selections are ideal for easy operator interface and the escape code sequences streamline automated control Serial TCP Messaging A direct TCP messaging protocol is supported for direct computer control of the A B switching system Installation The Control interface is located in the lower middle section on the rear of the K3 chassis The
2. Response Syntax The syntax for the command response is lt card gt lt status gt lt cr gt Example 01A card The number of the card status The status of the card either A or B K3 1RU AB Switch Page 16 cr The ASCII carriage return character If the queried card has been disabled then no response will be transmited In response to the Query All command 16 response messages will be sent All invalid commands will be ignored No response even when responses are enabled Gang Control Expansion G AB 1R The G AB 1RGang Expansion Card provides input and output of gang control allowing for simultaneous switching of multi chassis systems Connection is also provided for external power input from the K16 XPS or similar 24VDC source Installation The Gang Expansion interface is located in the lower middle section on the rear of the K3 chassis Connection between G K16X units or connection from C AB 16 R or other control card is made using 6 wire connection modular jack cords RJ11 RJ12 type Expansion Connector Pinout Pin Designation 1 amp 6 Ground 2 amp 5 Switch to B 3 amp 4 Switch to A oN gee Gang Out Gang In Alarm PS2 G K16x Rear View To control the system momentarily short either Switch to A or Switch to B to Ground K3 1RU AB Switch Page 17 A B Switch Modules The K3 Rack Mount AB Switching System can be factory configured with up to 3 AB switches of any of the
3. entered there Enter Password as programmed in the setup menu system The default password is PASS Please guard your password safely If the password is forgotten contact Dataprobe Tech Support Upon entering the correct password the main page will be displayed K3 1RU AB Switch Page 12 F T 1 Redundancy K 16 Ver 4 1A Internet Explorer File Edit view Favorites Tools Help Q bak CECENE DES Address http 192 168 1 254 A B Card Nest T 1 Redundancy tl Name Control Panel New York 1 Switch Control Philadelphia A el Card Select Gang Control System Power Supplies PS 1 On PS 2 OFF a feo Ol ee amp Bee oO E O E O Pi O d O 2 oO L O E F L Internet The web page shows the current status of each enabled card in the chassis It also displays the status of the two power supplies in the lower right corner To operate one or more switch cards Select the desired A B Card s using the checkbox next to the card and then click on the large A or B button under Switch Control The screen will refresh with the new card status shown Buttons for Select All and Select None assist in making selections The Web page will not automatically refresh if the A B cards are controlled using the manual switches In the event that switch cards are operated by front panel toggle switches or other external control a Refresh button is provided Click on this button to view the
4. syncStatus K3 1RU AB Switch Page 20 MIB Definitions k16RackName 1 3 6 1 4 1 1418 1 1 1 This read write variable is the name of the k16 nest This variable can be programmed either via SNMP Telnet or via serial port It can contain printable characters and MUST not exceed 20 characters in length k16CardTable 1 3 6 1 4 1 1418 1 1 2 This variable is not directly accessible k16CardEntry 1 3 6 1 4 1 1418 1 1 2 1 This variable is not directly accessible k16Cardindex 1 3 6 1 4 1 1418 1 1 2 1 1 k16Cardindex The card index This is a 0 based index so 0 is card 1 and 15 is card 16 k16CardName 1 3 6 1 4 1 1418 1 1 2 1 2 k16Cardindex This read write variable is used to set or get the name of an individual A B card The card name can only contain printable ASCII characters and MUST not exceed 20 characters in length k16CardPosition 1 3 6 1 4 1 1418 1 1 2 1 3 k16Cardindex This read write variable can be used to set or get the position of any of the 16 A B cards individually This variable uses an enumerated integer where 1 a 2 b 3 disabled 4 invalidCardIndex The values 3 and 4 cannot be used in the set command These are returned by the get and set commands when appropriate k16CardEnable 1 3 6 1 4 1 1418 1 1 2 1 4 k16Cardindex This read write variable is used to set or get the enabled disabled status of an A B card It uses an enumerated integer where 1 enabled 2 disabled 3 invalid index The value 3 cann
5. This trap is sent when ever any or multiple switches are changed by any means This trap will contain a variable binding for each card in the nest that has changed syncStatus specific 6 This trip is sent when ever the status of the nest synchronization changes It will contain the k16Sync variable Only available in special models K16 Series Standalone R1 Mount Page 22 TECHNICAL SUPPORT RETURNS and WARRANTY Dataprobe Technical Support is available 8 30AM to 5 30PM ET to assist you in the installation and operation of this product To obtain Technical Support call our Tech Support Hotline at 201 967 8788 or Email us at tech dataprobe com Please have the following information available when you call e Model of Product e Serial Number e Data of Purchase e Name of Seller if other than Dataprobe If you purchased this product through an Authorized Dataprobe Reseller you should contact them first as they may have information about the application that can more quickly answer your questions WARRANTY Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship for a period of One Year from the date of initial purchase If the product should prove defective within that period Seller will repair or replace the product at its sole discretion Service under this Warranty is obtained by shipping the product with all charges prepaid to the addr
6. following interfaces plus one control interface and power supply configuration Some switch interfaces occupy 2 slots SW1 amp SW2 Frame Ground Switching D9 15 and 25 model Only Jumper selection allows Pin 1 Frame Ground to be either switched or tied together and unswitched Pin 1 can also be tied to the Frame of the Chassis or left isolated from the chassis Signal Ground Switching Shown In Factory Default D9 15 and 25 model Only Ground Switched amp Isolated An additional set of jumpers provides the same switched common isolated or grounded for Signal Ground These jumpers control Pin 7 in the D25 model and Pin 5 in the D15 and D9 models The circuit is the same as shown above replacing Pin 1 for the correct pin and SG Signal Ground for FG Frame Ground Signal Ground Switching An additional set of jumpers provides the same switched common isolated or grounded for Signal Ground These jumpers control Pin 7 in the D25 model and Pin 5 in the D15 and D9 models The circuit is the same as shown above replacing Pin 1 for the correct pin and SG Signal Ground for FG Frame Ground Indicators Two Red LEDs indicate Switch status A or B LED s are driven by extra relay contacts Manual Switches Manual toggle switch on each card These are momentary switches Relays Sealed Telephone relays Gold clad contacts Maximum Contact Current 2 Amps 30 VDC Special DS 3 module Hi Freq 45 Mhz 55db Isolation K3 1RU A
7. most current status information K3 1RU AB Switch Page 13 If cards are not installed in the system their status will be reported as Position A To avoid confusion use the Disable feature in the Telnet Setup for unused card slots When cards are disabled their name will continue to appear on the web page or telnet screen however their status will be indicated as displayed in the screenshot below Note Card 4 16 are not available in the K3 system and have been disabled F T 1 Redundancy K 16 Ver 4 1A Internet Explorer File Edit view Favorites Tools Help Q Back a a e Address http 192 168 1 254l New York 1 New York 2 Philadelphia Gang Control System Power Supplies PS 1 On PS 2 OFF LI Fi E m d oO d oO L F d oO LI oO d Internet To simultaneously switch all cards in the chassis click on either the Gang A or Gang B buttons The checkboxes need not be used for this operation K3 1RU AB Switch Page 14 A logout button is provided Click this button to be instantly logged out There is an automatic logout function if there is no activity for two minutes You can also just close the browser however you will not be able to log back in for two minutes Telnet and Serial Port The menu system of the C AB 16 R is the same for Telnet and direct serial access For Telnet Enter the IP address of the C AB 16 R into your Telnet application program For Serial Direct Terminal Connectio
8. no activity The C AB 16 R will automatically terminate the session Should this occur simply re connect and re enter the password K 16 Set Location New York 1 New York 2 Philadelphia T 2 Bis 4 Ds 6 7 8 Je 1 16 Operate Switch A All toe TAT B All to T S Setup Xa Exit K 16 gt S Select S to access the setup Menu K 16 Set Location tup Menu Location Name t Location Card Setup Password Com Port 9600 8nl Escape Response No IP Settings Exit K 16 gt K3 1RU AB Switch Page 9 Select 6 for IP Settings The IP Settings Menu appears IP Settings IP Address 192 168 1 42 Subnet 255 255 255 0 Gateway 0 2 03 2200 Web Port 80 Telnet Port 23 Message Port 9100 MTU 1024 Write Community Name private Read Community Name public SNMP Manager 1 192 168 1497 Manager 2 0 0 0 0 Manager 3 Manager 4 0 0 0 0 0 0 0 0 26 Fa 4 Da 6 Ta 8 o A B Ca D X Enter the IP address Subnet Mask and Gateway in Dotted Decimal Format Setting IP address via Serial Port The serial port uses the same menu sequences as the Telnet method described above Connect a terminal directly to the C AB 16 R serial port Send an Enter keystroke to start the session The serial port default settings are 9600bps 8 data bits no parity one stop bit These setting can also be changed via the menus Setting IP Address with setip exe Utility setip e
9. B Switch Page 18 Specifications Switch Interfaces D25 Three 25 Pin D Subminiature Female Connectors 25 leads switched Option for Pins 1 and 7 common and unswitched RJ8 Three 8 position 8 wire RJ type Modular jacks Rear Panel Card Edge All 8 leads switched Support all RJ Configurations up to 16 Mhz NET Three 8 position 8 wire RJ type shielded modular jacks Rear Panel Card Edge Supports 10 100 1G Ethernet Interfaces DS3 Same as above but with special Dual BNC Module Individual transmit and receive circuits 45 Mhz T50 50 pin Telco Amphenol Champ connectors Common Male A and B are Female All 50 leads switched V35 34 pin Winchester Female connectors 19 Leads Supported Physical Rack Mount 19 Wide x 6 0 Deep x 1 75 High K3 1RU AB Switch Page 19 MIB Outine NOTE The K3 Series AB Switch System use the same network control interface as our larger K16 Series The same SNMP MIB interface is used with same values and commands Only the 1 three AB card slot positions of the 16 displayed are used in the K3 Displayed Slots 4 thru 16 are non functional Mib Tree iso 1 org 3 dod 6 internet 1 private 4 enterprises 1 dataprobe 1418 dpAgent 1 k16SwitchControl 1 k16RackName 1 k16CardTable 2 k16CardEntry 1 k16Cardindex 1 k16CardName 2 k16CardPosition 3 k16CardEnable 4 k16GangControl 3 k16PowerSupply1 4 k16PowerSupply2 5 Traps ps1Failed ps10k ps2Failed ps20k switchChanged
10. C AB 16 R controller provides the following connections 10base T Ethernet C AB 16 R only Network connection for access to the C AB 16 R card C AB 16 R Rear View Serial Port RS 232 port for out of band access to the C AB 16 R card n eeeeo pes Gang Expansion RJ11 connection z5 Gang PS2 for connection to additional card nests ati ee 10base T Serial Port Gan External 24VDC for large gang switching applications Ethernet REASON Power Input optional External Power Input Connection for external power supply K 16 XPS R for single or dual redundant power Mating Connector kit 1940164 K3 1RU AB Switch Page 6 Serial Port The Serial Port on the control card is a 9 pin male connector configured as a DTE The following pins are used The following chart illustrates the pin out of the D9 connector and the connection required to an external modem with a D25 pinout D9 Pin Abbreviation Full Name ae in Pin 2 RD Receive Data Pin 3 Pin 3 TD Transmit Data Pin 2 Pin 5 SG Signal Ground Pin 7 Pin 9 RI Ring Indicator Pin 22 For connection directly to a terminal a Null Modem cable is required C AB 16 R Terminal D9 Pin D9 Pin Pin 3 Pin 2 Pin 2 Pin 3 Pin 5 Pin 5 Configuration C AB 16 R Configuration of the The C AB 16 R involves the following steps e Setting The C AB 16 R s IP Address e Setting additional configuration parameters using Telnet Setting I P Address The C AB 16 R comes wit
11. K3 Series D dataprobe 1U Rack Mount A B Switches INC gt General Description The K3 Series A B Switching system provide up to 3 AB switches in a 1 75 in rack mount chassis for 19 Equipment cabinets Each switch allows a common circuit COM to be switched to either of two circuits designated A and B The switches can be controlled locally with a front panel toggle switch and remotely by contact closure or thru a Serial port and Ethernet connection using Telnet SNMP or a Web browser Modular System The K3 System consists of the K3 Chassis Model K3 R and Power Control and A B Switch options The following table illustrates the available K3 components available at the time of printing Additional options may be available contact Dataprobe SKU Model Description Base 1150100 K3 R K3 Chassis Control 1340062 C AB 16 R IP and Serial Control Card Individual Switch Control 1340065 C AB 1 R IP Control Card Gang Control 1340063 G AB 1 R Gang Expansion or GPI Control 1930077 PS R1 WRI Internal AC Power Supply 100 240VAC 1930078 PS R1 48 Internal 48VDC Power Supply 1930079 PS R1 224 Dual External 24VDC Power Supply For use with External AC Supply 1930076 PS WRI 4 External A C Power Supply 1110100 AB R D25 25 Pin D Subminiature all 25 pins supported 8 Wire Modular Jacks All leads switched Supports RJ48C RJ48S RJ45 and 1110101 AB R RJ8 all 8 position modular jack specifications up to16Mhz 1110102 AB R 2RJ8 Same as ab
12. and then reconnecting the power source Neither operation will alter the switch positions of any A B Card in the Nest MTU Maximum Transmission Unit Set the MTU from 100 to 1024 The default of 1024 should not be changed unless required by network architecture Read and Write Community Names These settings are for use with SNMP managers only Set the names as appropriate for your SNMP configuration SNMP Managers Set up to four SNMP managers that will receive SNMP TRAPs Other SNMP managers will be able to manage the system Operation Remote control of each or all A B Cards is accomplished using either TCP IP protocols for Web browser http Telnet or direct TCP messaging Each card in the chassis can be operated independently or all 3 A B cards can be operated simultaneously In all cases switch control is password protected Web Browser Operation To access the K3 using any web Enter Network Password x browser point your browser to the IP address of the C AB 16 R card Ifthe IP address is the default 192 168 1 254 then enter in the web browser address Site 192 168 1 254 bar http 192 168 1 254 gt Please type your user name and password Reali K 16 You may wish to bookmark this location User Name and rename the bookmark for easy reference Passworc _ You will be prompted for a User Name Save this passwod in your passwur list and Password The User Name is not ea used and any or no characters can be Cancel
13. ataprobe Applications Engineering Making Connection via Ethernet and Serial The C AB 16 R_ uses the TCP Transport Communication Protocol to communicate with the client PC To use the C AB 16 R__ establish a TCP connection Stream Socket to the C AB 16 R Be sure to use the Port assigned to the C AB 16 R _ either Port 9100 or the port assigned through the Setup Menus Once connected use the Send function to send the commands to the C AB 16 R_ and the Recv function to receive the C AB 16 R s response For the CP K16 R or the serial port of the C AB 16 R connection via the serial port requires only setting the computer to the proper baud rate and character format Command Syntax lt esc gt lt password gt lt a gt lt card gt lt 4b gt lt command gt lt cr gt Where esc The ASCII escape character 0x1b password The C AB 16 R password in ASCII case sensitive a The ASCII control a character 0x01 card The number of the card to be changed with or with out leading 0 s a or A all AD The ASCII control b character 0x02 command The command to be executed a or A Switch selected card to A b or B Switch selected card to B q or Q Display the status of the selected card cr The ASCII Carriage Return 0x0d The lt and gt in the syntax above are only to delineate the control characters and should not be sent Example To switch card 7 to B send lt esc gt PASS lt Aa gt 7 lt 4b gt B lt cr gt
14. ess below Seller will pay return shipping charges Call Dataprobe Technical Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPOSE ARE LIMITED TO THE WARRANTY PERIOD SET FORTH ABOVE AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from jurisdictions to jurisdiction WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the suitability of fitness for any specific application
15. h factory installed IP address 192 168 1 254 In most cases this will need to be changed Consult your Network Administrator to determine the appropriate IP address There are several methods to change the IP address e ARP e Telnet e Serial Port e setip exe program available from Dataprobe s web site To set the IP address the hardware MAC address must be known This address is located on a label on on the C AB 16 R printed circuit board The syntax for the MAC address is nn nn nn nn nn nn K3 1RU AB Switch Page 7 Setting the IP address using ARP To set the IP address using ARP connect the jack marked 10Base T to your local Ethernet network and apply power to the unit The computer used to set the IP address must be on the same physical network as the C AB 16 R ARP does not work across switched or routed networks Windows 98 and Later 1 Open a DOS window 2 Type the following command arp s lt IP Address gt lt MAC Address gt Where lt IP Address gt is the desired IP address in dotted decimal for the C AB 16 R and the lt MAC address gt is the MAC Address of the C AB 16 R The MAC Address is located on a label on the rear panel of the card Example arp s 63 211 86 165 00 50 c2 05 01 c1 lt enter gt new IP addr MAC addr 3 Ping the C AB 16 R to program the IP address into the C AB 16 R Type ping lt IP Address gt If the ping command returns host not responding 4 ti
16. l Port Parameters are 9600 8 Data Bits No Parity One Stop Bit 9600 8 N 1 Escape Response This selects Yes or No for escape code responses See section 3 4 3 on escape code control IP Settings IP Settings IP Address 192 168 1 254 Subnet 2959s 2909s 2904 0 Gateway 0 0 0 0 Web Port Telnet Port Message Port MTU Write Community Name Read Community Name SNMP Manager 1 SNMP Manager 2 SNMP Manager 3 SNMP Manager 4 2 om 4 5e 6 Ta 8 Ds A B Ca D XxX Exit K 16 gt IP Address Subnet Mask and Gateway Enter the appropriate information in dotted decimal format XXX XXX XXX XXX If you are unsure of the entries consult your network administrator Web Port Telnet Port Message Port These three settings determine the port assignment for the different TCP protocols used to communicate with the control card Standard port assignments for these protocols are WEB 80 Telnet 23 Message 9100 If you change these assignments you will need to specify them when you connect to the C AB 16 R For example if the IP address of the C AB 16 R is 192 168 1 254 and you have changed the web port to 8800 then you would need the following URL to access the C AB 16 R http 192 168 1 254 8800 K3 1RU AB Switch Page 11 Note After changing the IP Address Web Port Telnet Port or Com Port parameters it is necessary to reboot the C AB 16 R By removing power to the the K3 chassis momentarily
17. le Slot Redundant Capable Single Slot Dual Redundant Capable Input Power Input Power Nominal 120 240 VAC 50 60 Hz 100 240 VAC Nominal 48 VDC Range 100 240 VAC ae Range 42 60 VDC TN Watts 50 Watts 75 ALARM o Fusing 2A citar Fusing 2 5A uen Environmental Sd Environmental F Operating OC 65C Operating OC 65U Physical Physical AC Input connector DC Input Connector IEC 320 C14 onrear panel Screw Terminal Mating Connector Supplied Alarm Expansion connector 9 pin d Sub Alarm Expansion connector 9 pin d Sub Contact Ratings 1A 24VDC res Contact Ratings 1A 24VDC res K3 1RU AB Switch Page 4 Alarm Connector Alarm Connection on each power supply provides status information on the condition of the supply 9 Pin Dsubminiature Pin6 NO Pin 6 shorts to Pin 7 when the Power Supply is Non Operational Pin 7 COM Pin8 NC Pin 8 shorts to Pin 7 when the Power Supply is Operational Power Access Panel 1930079 Provides for connection of two K 16 XPS Power Supplies Input Power Nominal 24VDC Range 20 30 VDC gee gee Fusing 2 A Slo Blo Physical PS1 PS2 DC Input Connector Connector Molex 41995 Mating Connector Kit 1940164 Mating cable supplied with K 16 XPS K3 24VDC External PS Panel Rear View External Power Supplies 1930076 Power Input 100 120 200 240 50 60Hz IEC320 Male Power Input cord supplied for North America Power Output 24VDC 4 5A Connector Molex 41995
18. mes then the address has not been programmed properly or the IP or MAC Address is incorrect In either case redo step 2 If the problem persists contact the Dataprobe Tech Support Hot Line 4 Delete the entry from the ARP cache by typing arp d lt IP Address gt 5 Ping the C AB 16 R to confirm that it has been programmed If the card fails to respond repeat steps 2 4 above If the problem persists contact the Dataprobe support hotline Unix Linux Consult your systems administrator for information on setting an IP Address using ARP The unit should be pinged after the IP Address has been set to confirm proper operation Setting IP Address with Telnet For initial setup the computer used must use the same network segment as the default IP Address or current IP address 192 168 1 xxx If this is not the case use one of the other methods To connect to the C AB 16 R_ using telnet run your telnet client program provided with your operating system and connect to the IP address as set in step one above For Windows Select Run Telnet Connect 192 168 1 254 or the current IP address As soon as you connect the following message will be displayed K 16 Please Enter The Password Password gt The factory default password is PASS K3 1RU AB Switch Page 8 This password is case sensitive and can be changed in the setup process In telnet the The C AB 16 R has a security timeout feature After 2 minutes of
19. n press the Enter Key For Serial Connection via Dial up Modem Establish the dial link then press the Enter Key After entering the correct password the main screen is displayed K 16 Set Location New York 1 New York 2 Philadelphia Ta Zi 3 4 Dis 6 7 8 oe 1 16 Operate Switch A All to tA B All to T S Setup X Exit K 16 gt The screen shows all enabled cards and their current position A or B Enter any card number 1 3 to operate that card A or B to switch all cards to that position Enter S to access the setup menus see section 3 2 5 for setup details Enter X to logout of Telnet Card slots that have been disabled will not report any status NOTE Only the 1 three AB card slot positions of the 16 displayed are used in the K3 Displayed Slots 4 thru 16 are non functional K3 1RU AB Switch Page 15 SNMP Manager Control The C AB 16 R allows for management via SNMP The private MIB is available from the Dataprobe Web Site at http www dataprobe com files switch k16 k16 mib MIB Outline and MIB Definitions can be found in Appendix A Command Line and Direct TCP Messaging The C AB 16 R can be controlled via command line messages sent either over the serial port or using TCP messaging over the Ethernet port This allows streamlined communication between the C AB 16 R and network management systems or computer based monitor and control systems Programming support is available Contact D
20. n the Contact interface is installed Power Supply Status Indication The K3 has two LED indicators that display the current status of two power supply sources These are designated PS 1 and PS 2 LED ON Indicates the power supply source is connected PS 1 Internal Power Supply Module or External Power Supply 1 PS 2 External Power Supply 2 K3 System Page 3 The K3 series supports both internal and external power supplies Internal power modules are available to support worldwide A C power 48VDC and 24VDC power requirements External power supplies provide redundancy either when used in pairs or when combined with an internal module Power Supplies Modules The K3 Series can be powered by several types of power sources using four types of power supply options 90 240VAC 50 60Hz Internal module 90 240 VAC External module 48 VDC Internal module and 24 VDC direct Combinations of 1 internal 1 external supply or 2 external supplies can be used for redundant power applications Dataprobe offers the following internal supply modules for the K 16 series 193007 7 PS R1 WRI Internal AC Power Supply 100 240VAC 193007 8 PS R1 48 Internal 48VDC Power Supply 193007 9 PS R1 224 Dual External 24VDC Power For use with External AC Supply Power Supply 1930077 Power Supply 1930078 Converts 110 220 240 VAC to 24VDC Converts 48 VDC to 24VDC Sing
21. ot be used in the set command It is returned by both the set and get commands when the card index is invalid k16GangControl 1 3 6 1 4 1 1418 1 1 3 This read write variable is used to set the position of all cards in the nests It uses an enumerated integer where 1l a 2 b 3 writeOnly The value 3 is always returned form both the get and set commands to alert the operator that there is no data for this command to return K3 1RU AB Switch Page 21 k16PowerSupply1 1 3 6 1 4 1 1418 1 1 4 This read only variable returns the current status of the power supply 1 as an enumerated integer where 1 ok 2 failed k16PowerSupply2 1 3 6 1 4 1 1418 1 1 5 This read only variable returns the current status of the power supply 2 as an enumerated integer where 1 ok 2 failed k16Sync 1 3 6 1 4 1 1418 1 1 6 This read only variable returns the status of the synchronization channel special models only as an enumerated integer where 0 ok 1 fail Trap Definitions ps1Failed specific 1 This trap is sent when ever power supply 1 fails It carries not variable bindings ps10Ok specific 2 This trap is sent when ever power supply 1 returns to serves It carries not variable bindings ps2Failed specific 3 This trap is sent when ever power supply 2 fails It carries not variable bindings ps2Ok specific 4 This trap is sent when ever power supply 2 returns to serves It carries not variable bindings switchChanged specific 5
22. ove with two ganged switches 8 Position 8 Wire Modular Jacks All leads switched Supports 10 100 1G 1110103 AB R NET Ethernet Network specifications 50 Pin Telco Amphenol connector All 50 Leads Switched Dual Height 1110104 AB R T50 Switch must be in Slot 1 34 Pin M Type V 35 connector 23 leads switched Dual Height Switch must 1110105 AB R M34 be in Slot 1 1920028 AB FP Blank Panel for unused A B Slots Required for FCC and CE marking K3_system_v070607e robe Technical Support 201 934 5111 tech dataprobe com J zdataprobe Main 201 934 9944 Website dataprobe com K3 System Page 2 Installation amp Operation K3 Chassis The K3 Chassis holds the Power Control and A B Switch modules for the K3 system It installs in a standard 19 EIA equipment cabinet requiring 1 75 1U of rack height K3 systems are preconfigured and tested in the factory All Control Power and Switch modules are pre installed Manual Switch Control A front panel momentary toggle switch for each A B Switch installed allows local manual control AB Switch Status Indication Two front panel LED s for each A B Switch installed indicates switch position A or B Individual switch status can also be monitored thru the Network or Contact control interface Remote alarms or displays can be controlled by the status signal of each switch which are provided as form C relay contacts whe
23. xe is available from Dataprobe s website at http www dataprobe com files control setip exe Download this windows program and run it on any computer on the same physical network segment as the control card Enter the MAC address and desired IP address and press SetIP Setting other Parameters Via the Serial Port or telnet on the C AB 16 R all other configuration parameters can be set for the C AB 16 R These setting are made from the Setup Menu as described in the section 3 1 3 above Location Name Enter a 1 20 character name to identify the system This name appears at the top of each telnet screen and web page Card Setup This allows setting of parameters for individual A B cards in the system Each card can be named up to 20 characters and can be enabled or disabled Disabling a card hides its status from web and telnet screens This should be used where no card is installed to make reading the screens easier NOTE Only the 1 three AB card slot positions of the 16 displayed are used in the K3 Displayed Slots 4 thru 16 are non functional Password A password from 1 to 15 characters is needed for access to the system Re enter the old password then enter the new password twice as prompted K3 1RU AB Switch Page 10 Com Port Set the Baud Rate and Character Format for the serial port Baud rate choices are 9600 19200 and 38400 Character format choices are 8N1 7E1 and 701 databits parity stop bit The Default Seria