Haier AS102AMARA User's Manual

image

Contents

1. Turn on the machine and let it operate for half a day under the status of sending air in a sunny day so as to make the inside of the air conditioner fully dry Clean the dust filter the indoor unit and outdoor unit then cover it Notes for Safety Do not spray any paint or insecticide on the air Conditioner a Insecticide Eo Maintenance before Season of Use Check the inlet and outlet of the outdoor unit see if they are blocked Never pour water on the indoor unit Keep the inlet and outlet of the indoor unit unblocked The dust filter must be installed to ensure the air filter to be clean otherwise dust would enter to damage the machine or cause failure When the louver is being swung never touch Operate the unit with the remote controller the outlet or put anything into the air grille NS The instructions with this warning mark must be carried out strictly for they are all concerned with safety of the product or human beings The instructions with this prohibiting mark must be completely forbidden otherwise the product would be damaged or the human being would be injured 15 Maintenance Installation and Replacement of Air Filter 1 Open the inlet grill as drawing Dust Filter 3 Install the air filter by inserting it into left and right frames with the white side upward Air Filter 4 Install back dust
2. anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room Installation 1 Installation Localization 2 Indoor Unit Mounting Plate Localization 3 Drill through Wall 4 Connect Indoor Unit 5 Install Indoor Unit 6 Install Outdoor Unit 8 Drain Out i i ni ug Trial Operation 12 Wind up Pipes The step 4 and step 5 above can be adjusted according to the practical situation This procedure is a reference to the installation person and customer it can be adjusted according to the practical situation 25 Installation To enable the air conditioner to work well please install it as required by this manual When moving the air conditioner please don t scratch the shell The max length of the connection pipe is 15 meters and the max height difference between the indoor unit and outdoor unit is 7 meters for ASI22 AVARA AUI22 ACARA HSU 12H03 DB ASI22AYARA AUI22ACARA HSU 12HA03 DB and 5 meters for ASIO2ALARA AUIO02ACARA HSU 10H03 DB ASIO2AMARA AUIO2ACARA HSU 10HA03 DB 9 Please keep this manual carefully for maintenance and installation After installation please operate the air conditioner as per this manual Electrical Requirements 9 A specialized power supply wire which shall be installed
3. be wound up with the insulating material B Insulating Material 0000000 si Pipe Clamp Right Connection Low Connection Left Connection Electrical Connection between Indoor and _ Outdoor Units Tape Installation of the Connection Pipe Clips Left or Left Back Connection 9 Insert the pipe clip into the fixing position of the pipe with the upper part inserted first 9 Press the bottom of the clip until a sound Ka Ta is heard Ss Pipe Clamp na 27 Installation Localize the Installation Indoor Unit Install the indoor unit where the weight of the unit can be supported Install the indoor unit where the head source and steam source are not close and the unit inlet and outlet are not blocked Install the indoor unit where the drainage is easy and the outdoor unit can easily connected Install the indoor unit where its cold air and hot air can be easily sent to all the corners of the room Install the indoor unit where the power socket is near and there is sufficient space around the indoor unit Install the indoor unit where there is no T V set radio set and wireless appliance underneath and the sunlight lamp is over one meter away If the remote controller is installed on the wall the indoor unit shall be ensured to receive the signal while the sunlight lamp is on Outdoor Unit The location shall bear the weight of
4. by a competent person as per the rules of the national standard Power supply socket must be close to the air conditioner And the socket must have an earth to make the air conditioner be grounded through the power supply socket Ifthe power supply wire is damaged it must be replaced by the manufacturer or its service center or professional person e Power supply wire parameters 3 X 1 5mm for ASIO2AMARA AU102ACARA HSU 10HA03 DB AS102ALARA AU102ACARA HSU 10H03 DB ASI22AVARA AUI22ACARA HSU 12H03 DB AS122AYARA AU122ACARA HSU 12HA03 DB Connection wire parameters 3G1 5mm 1 X0 75mm Hose Selection description Size Liquid hose 6 35mm 1 4 AS122AVARA AS122AYARA 12 7mm 1 2 AUI22ACARA AUI22ACARA HSU 12H03 DB HSU 12HA03 DB Gas hose ASIO2ALARA ASI02AMARA 9 52mm 3 8 AUIO2ACARA AUIO2ACARA HSU 10H03 DB HSU 10HA03 DB Notes After installation please confirm that the refrigerant is not leaked 24 Operation Cooling Dehumidifying Heating Operation Recommended Modes Cooling mode for summer Heating mode for winter Dehumidifying mode for spring and fall 1 Turn on the Air Conditioner Press On Off button to start the air conditioner Previous operation status appears on display working method indicator lights up 2 Select Operation Mode Press mode button For each press mode changes as follows m x Cooling Dehumidifying Heating
5. filter Left filter and right filter are different in shape so never make it wrong dust filter must be installed Maintenance Clean the Air Conditioner Do not touch the machine with Turn off Power wet hands Do not clean it with hot water or detergent ON S OFE D Open the inlet grill upward Remove the dust filter Slightly push it upward then Pull it downward Clean the Dust Filter Clean the dust filter with water or vacuum cleaner When the filter is too dirty clean it with detergent S ui or medium soap liquid Then flush it with water and dry it in sunshine Finally fix it back Remove the Old Air Filter 7 2 _ i Install Air Filter Notes The air filter is optional Please approach the nearest local maintenance center to buy Replace Air Filter i 2 the air filter according to the replacement time in Air Filter Instructions Hints This model of air conditioner falls into two types one is with a multiple light catalysis air filter the other with an air filter without multiple light catalysis So the maintenance should be done accordingly The multiple light catalysi
6. hear sound Hua Hua then release the pressing then the test operation begins Now the unit works under Hi air speed and the power or healthy operation indicator on the indoor unit lights up The air conditioner will be automatically turned off after test operation lasts 30 minutes Turning Off Cancel Test Operation Press the Test manually button you will hear a sound Hua then all the indicators on the unit will go out Cancel Test Operation with Remote Controller Press the On Off button you will hear a sound Hua then the air conditioner will work as displayed on remote controller 13 Notes for Safety The power supply plug must have the earth line to ensure that the air conditioner may be grounded effectively through the power supply socket Non grounding or incomplete grounding would result in electric shock After electric wiring the air conditioner shall be electrified to check for electric leakage Trouble Shooting The followings are not malfunction Water flowing sound is heard When the air conditioner is started when the compressor starts or stops during operation or when the air conditioner is stopped it sometimes sounds shuru shuru or gobo gobo It is the flowing sound of the refrigerant and it is not a trouble Cracking sound is heard This is caused by heat expansion or contraction of plastics Clean the d
7. the unit and will not produce a big vibration and noise The location shall be in good ventilation and the airflow blew out and noise produced shall not affect the neighbors The location shall not be directly drenched in rain sun or blew by sea wind The location shall not be near anywhere the corrosive gas SOz flammable gas thinner or gasoline oil mist or steam are probably produced for example in kitchen Sufficient space shall be left for air inlet and outlet 9 The location shall be easily maintained and repaired 9 t cannot be installed on a non professional metal structure like anti burglary net Method for Cutting and Expanding Pipes When the pipe is too long or its mouth is damaged the pipe needs to cut or expand 1 Cutting hose 2 Removing burr a ee Hose dia Size mm f YQ Liquidhose 6 35mm 1 4 0 8 1 5 Gas hose 9 52 mm 3 8 1 0 1 8 3 Put on nut 4 Expand Hose 12 7 mm 1 2 1 2 2 0 Gen He E ZA Refrigeration Oil Piping Connection m 1 Connecting Method Connector Nut To ensure the efficiency the pipe should be as short as Hose Expander possible Apply refrigerant oil at half union and flare nut 44 9panner 9 To bend a pipe five the roundness as large as possible P Spanner not to crash the pipe When connecting pipe hold the pipe center to center then screw nut on by hand refer to the Drawing Correct Not Corre
8. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper diposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon All these valuable materials may be taken to a waste collecting center and used again after adequate recycling Consult your local authorities for the name and address of the waste materials collecting centers and waste paper diposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guide carefully The user s Guide contains very important observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept responsibility for any damages that may airse due to non observation of the following instruction Damaged air conditioners are not to be put into operation In case of doubt consult your supplier Use of the air conditioner is to be
9. SPLIT AIR CONDITIONER OPERATION MANUAL AS102AMARA AU102ACARA HSU 10HA03 DB AS102ALARA AU102ACARA HSU 10H03 DB AS122AYARA AU122ACARA HSU 12HA03 DB AS122AVARA AUI22ACARA HSU 12H03 DB Digital DC Variable Frequency Healthy Split Air Conditioner Please read this manual carefully before use e Please keep this manual carefully and safely No 0010540438 I Contents CAUTIONS NO T 1 2 Name of PAIS MM 3 4 Operation ITS va icine tasiateua ipe bracelet dol EAE ERE ON dM Radon 5 6 CODE coeurs tede IM EE E E EUN poset tere isesine eater 7 13 Notes TOP SEG V as detto eot tima Eobbini E Mei oiv n tpi v unt os SEP dank 14 15 MamtenanCE MNT c 16 18 GEA S EOD IG ossis tae eret Eva L fite as ot ae 19 21 MANS AAI m 22 30 Installation Check and Trial Operationen piget prn ER qe Ud EUREN 31 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use please make sure it s inoperative and safe Unplug the air conditioner in order to avoid the risk of child entrapment It must be noticed that air conditioner system contains refrigerants which require specialized waste disposal The valuable materials contained in a air conditioner can be recycled Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question
10. When the compressor operates as the panel displays working method indicator on indoor unit lights up During heating if the outdoor unit frosts the machine will stops heating automatically to defrost meanwhile neither of the indoor unit fan and outdoor unit fan will work 3 Select Temperature Setting Press Temp button A Each press increases by 1 C w Each press decreases by 1 C When Unit operation the room temperature will be the same with temperature display on LCD 4 Fan Speed Selection Press Fan button each press change the fan speed as follows The fan works at the displayed speed Hints The remote controller can remember the working status of each time Each time when you press the Turn On Off button the air conditioner will work at the previous status Operation Installation Installation Tools 5 Adjustment of Air Flow Direction 1 Screw Driver flat head wabbler triangle After selecting the mode swing louver will automatically be opened to the position as the drawing 2 Steel Saw indicates 3 60mm Drill 4 Inner Hexagon Spanner 5 Shifting Spanner 6 Spanner 14 17 19 27 mm Cooling Mode Horizontal 7 Pipe Cutter Approx 10 Heating Mode D 8 Pipe Expander Approx 60 9 Knives Up and Down Adjustment with remote controller 0 Clippers Press swing button once the swing louver will swing automatically within the range as It Leakage Checkerui Soap Linii indicated in the drawing press
11. ay after pressing the on off button reload the batteries Notes Use two same typed batteries when loading If the remote controller cannot run normally or doesn t work at all use a sharp pointed item to press the reset button with the mark Operation Small Hints all the symbols and resume working very soon Remove the batteries in case the unit won t be in use for a long period The remote controller will be self checked after loading the new batteries by displaying Health Operation 1 After turning on the air conditioner set to the desired mode The remote controller displays the mode selected the power light on the indoor unit lights up 2 Set Healthy Operation Press the Health button once is displayed and the power or healthy operation indicator turns from orange color to green Now the air conditioner is operating the healthy function meanwhile the anion generator in the indoor unit begins to release anion to clean the air and eliminate dust 3 Cancel Healthy Operation Press the button Health again to stop the health display then the healthy operation stops Notes When the fan in the indoor unit does not work the health lamp lights up but the anion generator does not release anion Brief Introduction to Health Operation The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of posion and
12. blow or the fan speed cannot be During the dehumidifying operation when the changed during the dehumidifying mode room temperature is less than 2 C higher than the temperature set the air conditioner will operate at low fan speed intermittently regardless to the fan speed set Water or steam generates from the outdoor unit This results from removal of the frost accumulated on the outdoor unit Defrosting K f operation during heating During heating the fan in the indoor unit still To eliminate the afterheat the fan in the indoor works even after the unit operation stops unit will still operate for a while after the unit automatically stops Itis due to the accumulation of anion which There would be sooting around the outlet and a aM can be cleaned after the unit is turned off The sound Si Si would be heard sound Si Si is due to generation of anion Operation Emergency Operation amp Test Operation When your remote controller is lost or cannot be used the unit can be operated with a function of emergency operation The test operation can be applied when the cooling test operation is carried out under the room temperature of 16 C Emergency Operation It can only be used when the remote controller is lost or damaged Turning on Press the emergency manual button you will hear a sound Hua then the emergency operation begins This time the power or healthy operation indicator
13. carried out in strict compliance with the relavtive instructions set forth in the User s Guide e Installation shall be done by professional people don t install unit by yourself Cautions For the purpose of safety the air conditioner must be properly grounded in accordance with specifications e Always remember to unplug air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet All electrical repairs must be carried out by qualified electricians Inadequate repairs may result ina major source of danger for the user of the air conditioner Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner s tubes with sharp or pointed items crushing or twisting any tubes or scraping the coatings off the surfaces If the refrigerant spurts out and gets into eyes it may result in serious eye injuries Do not obstruct or cover the ventilation grille of the air conditioner Do not put fingers or any other things into the inlet outlet and swing louver Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit Specifications e The refrigerating circuit is leak proof The machine is adaptive in following situation 1 Applicable ambient temperature range Maximum D B W B 32 C 23 C Minim
14. ct Be careful not to let foreign matters such as sands enter the pipe uf is bj uU Pipe dia Recommended Tilting expanded burr incomplete too long Fastening Torque Liquid pipe 6 35mm 1 4 18 N m Gas Pipe 9 52mm 3 8 42 N m Gas Pipe 12 7mm 1 2 50N m 26 Operation Remote Controller s Operation When in use point the signal sending head directly to the receiver window on the indoor unit The distance between the signal sending head and the receiver window should be within 7 m without any obstacle as well Don t throw the controller prevent it from being damaged When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter Loading of Batteries Load the batteries as illustrated in the drawing below Remove Battery Cover Slightly press and push down the cover Then as the drawing hold the upper end of the remote controller with left hand and slightly hold the cover with right hand push slightly in the arrow direction to remove the battery cover Load Batteries Be sure that the loading is in line with the as illustrated Put back Cover Put back the cover in the reverse procedure Confirmation Indicator If there is no displ
15. de change in the following sequence No Display gt OFF ON Timer Off Timer On ee The timer mode displays off or on The time displayed indicates the time set last time The timer mode on the indoor unit lights up Piping Cover lt Insulating Material Cirio AME Notes Selecting No Display cancels the timer mode 3 Time Setting Press TIMER button A Every time the button is pressed time increases one hour If the button is kept depressed time will change quickly v Every time the button is pressed time decreases one hour If the button is kept depressed time will change quickly Time can be adjusted within 12 hours Time will be shown on LCD The time setting is to automatically turn on or off the air conditioner a certain number of hours later Non adhesive Tape p 8 Pipe Clip Connection Wire Insulating Material 9 Notes After the batteries are replaced the time set resumes as below Time set off for 1 hour Drain Hose Time set on for 6 hours Ifnecessary time can be reset after power goes out time should be reset Cancel Timer Mode Just press TIMER button until TIMER mode disappears on LCD Operation Super Mode Operation When you need to cool or heat your room rapidly you can use this function Set Super Mode Operation Press the POWER button each time the display will vary in t
16. e Here installation drawing Mounting Plate D Holes for Fixing Wire Dropping Weight Al45mm _ gt 9 A T Find out the Level Position A 185mm Oo 60mm 1 Fix the Mounting Plate and Localize the Wall through Hole Fix the mounting plate as per the selected position and the piping layout see the installation drawing Fix the mounting plate on a smooth wall surface under the beam or beside a column First fix the mounting plate with a steel nail then level it with a level meter or a drop line then fix it with A4 X 50 cement nails If the expansion screws are used first drill holes into the wall 4 8mm then put the plastic sleeve into the holes then fix the mounting plate with 4X25 screws Measure the position the wall hole with a measuring tape 2 Drill a Hole through the Wall and Install the Piping Protective Sleeve Drill a hole P 60mm through the wall with the outer side slightly downward then install the piping sleeve then seal it with gypsum powder Inter side Outer side Wall hole Thickness of wall do 60mm 3 Piping Layout for Indoor Unit Section plan of wall hole Lay out the connection pipe drain pipe and the connection wires according to the installation position of the indoor and outdoor units During the layout the drain pipe shall be placed underneath and the connection wires shall be placed on the top the drain pipe especially indoor or inside the unit shall
17. e Screw amp Pipe outlet would leak water Bushing an 6 Turn off Press ON OFF button to turn off the unit all the displays disappear from LCD and all the lamps Qty on indoor unit go out And the swing louvers will all be closed automatically Notes After turning off the unit must not be restarted until 3 minutes later to protect the system No TI 2 3 Hints er Shape Piping Hole Rubber Connection As cold air flows downward in COOL mode adjusting air flow horizontally will be much more P is Cochiot Wire helpful for a better air circulation As warm air flows upward in HEAT mode adjusting air flow downward will be much more helpful OS for a better air circulation Be careful not to catch cold when cold air blows downward Qty Installation Operation Installation Drawing for Indoor and Outdoor Units Time Set Operation With the time set function the air conditioner can be turned on and off automatically at your set time You can let your air conditioner be turned on or off automatically after you wake up in the morning before you come back from work in the evening or after you fall asleep at night 1 After turning on the air conditioner select your desired mode The operation mode is displayed on the LCD of the remote controller and the working method indicator on the indoor unit lights up 2 Timer Setting Press TIMER button to change the timer mode each press makes the timer mo
18. ealthy operation Timing Mode Display Indicating time set mode Normal for non time set Timed off for timed turning off Timed on for timed turning on Indicating the Time set Indicating the time set on and off Mode Selection Selecting the modes below cooling dehumidifying and heating Timer Used to select TIMER ON TIMER OFF Time Set To set the time on and off Signal Sending Head To send signal into the signal receiver on the indoor unit Signal Display It blinks when the signal is being sent Temperature Display To display the temperature set Temperature Set To set the desired room temperature On Off Button To turn on and turn off the air conditioner Air Volume To select the desired air speed Air flow Direction To adjust the air flow direction Healthy Button To set the healthy operation Power Button To set super or soft operation Indication for Power Operation Reset When the remote controller appears abnormal use a sharp pointed item to press this button to reset the remote controller to normal condition After replacing the batteries in the remote controller press on off button the mode is resumed as below Mode Refrigerating Temperature 26 C Timer Normal Fan Speed Automatic Installation Piping Connection for Outdoor Unit Connect the Piping and Inlet and Outlet Liquid Tubes Gas Drainage Method Drain the air in the indoor unit and the pipes as per the drawing 1 Remo
19. he connection wire end into the When the air conditioner is at the state of time set this indicator lights up terminal block completely screw it tightly then slightly pull out the 7 Test Manual Button connection wire to ensure it be clamped tightly This button is only used for test refrigerating operation when the room temperature is below 16 C so it should not be used in normal situation 8 Emergency Manual Button When the remote controller is lost or cannot be used this button can make the air conditioner continue to operate for the time being 9 Remote Signal Receiving Window 3 Method for Pressing the Connection Wire After wiring the connection wire must be pressed tightly with a wire pressing clip which should press the outer sleeves of the wire as the right drawing l l Correct Pressing Wrong Pressing It receives the remote signal from the remote controller Terminal 10 Working Method Indicator Plock When the compressor is working the indicator lights up 11 l HS j LE BEI 11 Power Plug 5 Pressing 5 5 Clamps Wiring for Indoor Unit and Outdoor Unit Lay out the connection wires as the connection drawing Notes The two ends of the connection Outdoor Unit wires are different never connect reversely i fulet 1 Open the wire cover unsc
20. he following sequence i T No 1 Stop at At the state of Super Mode Operation when cooling the temperature will be 4 C lower than the temperature set and the fan will automatically run at high speed for 15 minutes then return to the previously set state when heating the temperature will be 6 C higher than the temperature set and the fan will automatically run at mid speed for 15 minutes then return to the previously set state Cancel Super Mode Operation Press the POWER button twice until the display disappears Soft Mode Operation When you need silence you can use this function Set the Soft Mode Operation Press the POWER button each time the display will vary in the following sequence lid T No aa Stop at a At this state the fan speed is Low Cancel Soft Mode Operation Press POWER button once until the display disappears Hints When at the state of Super Mode Operation the room temperature would not be even And long time soft mode operation would make the room temperature neither too cold nor too hot Power Failure Resume to be applied for a necessary situation only for the models ASIO2ALARA AU102ACARA HSU 10H03 DB ASI22AVARA AUI22ACARA HSU 12H03 DB ASI02AMARA AU102ACARA HSU 10HA03 DB ASI22AYARA AU122ACARA HSU 12HA03 DB After the power failure compensation is set if power failure suddenly occurs whi
21. ion 1 m a Only when the air conditioner is at the state of operation Healthy Operation Indication Healthy Button normal state can the healthy operation be started When the button Health is pressed the healthy operation will be indicated Operation Hints Wait a moment Cold Air Prevention When heating is started the fan in the indoor unit will not be started immediately to prevent cold air being blew out Defrost During the heating when the heat exchanger in the outdoor unit is frosted the air conditioner will defrost automatically for a few minutes During the defrost the fan in the outdoor unit does not run until the defrost is completed Notes When heating the air conditioner takes a lot of heat from outdoor and release the heat into the room therefore the outdoor temperature will affect the heating effect Instructions Operation Adjust the air flow direction Avoid the direct sunlight and hot air flow d AVA Set a proper room temperature Use of Timer Too cold and too hot are not only harmful for Time set can make your room in a comfortable health but also will consume too much electricity temperature when you wake up or come back temperature Notes After installation please confirm that the refrigerant is not leaked 6 Installation Installation of Indoor Unit The indoor unit shall be installed as per the indoor unit Hanging Wire Drop Wir
22. lamp on the indoor unit lights up The air conditioner will automatically run as the mode below Please check your air conditioner as the procedure below before contacting the local maintenance center for after sales service The air conditioner cannot be started Is power switch on Is power supply normal Is the leakage breaker tripped Please switch off the power supply immediately and contact the local maintenance position ON center The power switch is not on the 20 indoor temp Temp set Timer Air speed Mode Health Operation Above 23 C 26 C No Auto Cooling No Below 23 C 23 C No Heating No During emergency operation the temperature set and air speed cannot be changed Besides the dehumidifying and timer operation cannot be operated either Turning Off Cancel Emergency Operation Press the Emergency Manual Operation button you will hear a sound Hua then all the indicators will go out Cancel Emergency Operation with Remote Controller Press the On Off button you will hear a sound Hua then the air conditioner will work as the mode indicated on the remote controller Test Operation This is for test cooling operation under 16 C indoor temperature It cannot be used under normal condition Turning On Keep pressing the Test Manual button button for 5 seconds you will
23. le the air conditioner is working it will resume the previous working state when the power is supplied again Notes When a power failure suddenly occurs during the air conditioner is working after the power failure resume is set if the air conditioner will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the On Off button after the power comes again 12 Trouble Shooting Insufficient Cold Air or Hot Air Has the mode been selected correctly Is the dust filter too dirty it should be cleaned once every two weeks CO Is the door or window open Insufficient Cold Air Is there any other hot resources in the room into the room isc a Bs Hen 4p Is the sun light directly sent Are there many people in the room n Lo at peL Ue VI do N NS TN SS Cold Air is Blew out during heating operation Is the unit under heating operation If after the above mentioned checks are made and treated accordingly the air conditioner still cannot work normally or one of the following facts are found please stop the operation and contact your local service center Fuse or circuit breaker often breaks Water is leaked during cooling and dehumidifying Working abnormally or abnormal sound is heard 21 Trouble Shooting Air does not
24. ll or roof the stand shall be firmly fixed to resist the earthquake or strong wind A vibration reduction rubber ring shall be used O bus i 500 105 2 Install the Drain Elbow The elbow is only used for the thermal pump type air conditioner And the cold air type air conditioner does not need it The elbow shall be installed as per the drawing The drain elbow is not used in a very cold weather the air temperature is below 0 C for long eL Drain Elbow Dran Hose 28 Operation Hints Air Conditioner Operation When the ambient humidity is too high the anion effect would be reduced so during the cooling and dehumidifying water would drop from the outlet mouth 3 Minutes Protection When the air conditioner is turned on immediately after being turned off the compressor will not start until 3 minutes later to protect the machine Air Speed Change At the state of cooling when air is setto automatic the air speed would decrease automatically when the room temperature is close to the set temperature In heating mode when the room temperature is the set temperature compressor will stop and fan will be low speed or stop In dehumidifying mode air speed will change automatically Air Direction Adjustment At the state of cooling or dehumidifying it would be better not to let the outlet guide plate be downward for long otherwise the outlet mouth would be dew Healthy Operat
25. or units firmly inserted into the terminal plate Are the electric wires on the indoor and outdoor units fixed firmly Is the drain pipe placed correctly Is the earth line connected firmly Does the power supply voltage conform to the electric regulations Is there any noise Is the cooling operation normal Is the indoor temperature adjuster working normally Power Supply L should be connected with the live wire N should be connected with the zero wire should be connected with the earth wire 31 Installation Name of Parts Indoor Unit 1 Inlet Grill 2 Anion Generator inside 3 Air Filter 4 Swing louver It can be adjusted to upward or downward with the remote controller only Do not adjust it manually Wiring for Indoor and Outdoor Units 1 Wiring Method for Ring Terminal The wiring method is as the drawing below for the ring terminal Remove the connection screw and put the screw through the ring on the connection wire terminal then connect it to the terminal blocks then screw it tightly 5 Power or Healthy Operation Indicator Wiring Method for After the air conditioner is started this indicator lights up when the healthy operation is started this 2 Wiring Method for Line Terminal Ring Terminal Block indicator turns green The wiring method is as follows for the non ring terminal 6 Ter Set Indicator Loosen the connection screw and insert t
26. rew the pressing clamp outdoor unit Outlet 2 Connect the connection wires as per the wiring method and the wiring drawing the wires on i Send out hot air when cooling the indoor unit shall be inserted from behind as the attached drawing and send out cold air when heating 3 Ensure that the terminals are clamped tightly and press the connection wires outdoor unit as 3 Inlet er the pressing method then install the wire pressing cover P P d P S 4 Connection pipe and electric wiring 5 Drain Hose Air Inlet Grille A Pressing Cover Terminals Pressing Clamp 1 m Screw Power Supply Wire Indoor and Outdoor Connection Wires Notes When connecting the wires of indoor and outdoor units check the numbers on the terminals of the indoor and outdoor units the same wire shall connect the same number and color mmu terminal Wrong connection would damage the air conditioner s controller or the unit cannot work x77 30 3 Name of Parts Remote Controller Introduction to Display and Function 1 10 1 12 13 14 15 16 17 18 19 Notes Mode Mode selected is displayed Air Volume Indicating the air speed when automatic is set the air speed changes according to the temperature difference between the indoor temperature and set temperature Healthy Operation Indicating h
27. s air filter shall be put in sunshine once every half a year 8 hours each time while the air filter without the light catalysis shall be replaced every half a year which can be purchased in the local service center 16 Notes Do not clean the dust filter with water higher than 40 C otherwise it would be damaged Clean the dust filter gently and carefully Clean the Indoor Unit and Outdoor Unit Clean it with wet cloth or medium detergent then clean with dry cloth The water cannot be higher than 40 C otherwise the unit would be deformed or discolored And never clean it with insecticide or other chemical detergent 17
28. the button again the swing louver will stop at the current position 13 Measuring Tap The remote controller will remember the current swing position and each time when you turn 13 S raper or File on the air conditioner the swing louver will automatically stop at the position set previously 14 Refrigeration Oil Self contained Accessories Gypsum Drain Hose Pipe Clip Approx 0 adhesive Insulation Powder Cooling approx 45 K Notes Heating approx 60 Accessories Delivered with Your Air Conditioner When cooling or dehumidifying do not let the swing louver be downward for long time Please check if your unit is delivered with the following accessories otherwise the outlet would be dew and leak water Even ifthe louver is downward for long No 3 A time after one hour it will be automatically moved to the position which is 10 to Shape eem Bafisties Drain Hose horizontal position Don t turn the louver manually otherwise it would work abnormally If sonis the swing louver works abnormally turn off the unit then turn onagain adjust it with the remote controller SE e Left and Right Adjustment manual As the drawing below turn the vertical louver to adjust the left and right air flow direction Qty 1 2 1 1 Notes No 10 When the humidity is very high if all the horizontal Shape Connection louvers are turned left or right th
29. um D B WB 18 C 14 C Cooling Maximum D B Minimum D B Indoor Maximum D B l ndoor Minimum D B Heating Maxi D B W B 24 CA8 C aximum D Outdoor Maximum D B WB 7C 8C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is HOSRN F or HO7RN F 3G1 5mm 1X0 75mm 3 If the fuse on PC board is broken please change it with the type of T 3 15A 250V If the fuse of outdoor uit is broken please change it with the type of T 25A AC250V 4 The distance between the indoor unit and the floor should be more than 2m 5 The wiring method should be in line with the local wiring standard 6 After installation the power plug should be easily reached 7 The waste battery should be disposed properly 8 The appliance is not intended for use by young children or infirm persons without supervision 9 Young children should be supervised to ensure that they do not play with the appliance 10 The requirement of power supply cord Series 10 12 European HOSVV F HOSVV F region 3G 1 5mm 3G 1 5mm Installation Check and Trial Operation Please operate the air conditioner in accordance with this Operation Manual Check items for the Trial Operation Tick v inL 1 Is the connector leaked How is the connector insulated Is the electric connection between the indoor and outdo
30. ust filter periodically Blockage of the dust filter would reduce the cooling and heating effect consume more power water would be leaked during cooling and other failures would also occur Use the fuse of required capacity Never use steel wire or copper wire to take place of the fuse 3 ae Steel wire Copper wire It smells During operation white fog comes out of indoor unit SET a Air which blows out from the indoor unit sometimes smells The smell results from residents of tobacco smoke or cosmetics stuck inside of unit During the cooling and dehumidifying operation a thin white fog would be sprayed out of the indoor unit It is a watery fog formed by a condensed air blew out of the unit During cooling mode it is automatically switched to Fan mode To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the Fan Mode but it will soon be returned to the cooling mode Never connect the earth with the gas pipe water pipe lightening arrester or phone line Never install the air conditioner where the flammable gas is easily leaked The air conditioner cannot be restarted soon after it stops o This is due to its self protection function therefore the machine cannot work until three minutes later Wait for three minutes KR 19 Maintenance Maintenance after Season of Use
31. ve the valve cap on the two way valve of the indoor unit with a spanner 2 Unscrew by 1 2 cycle the nut on the mouth of the thick pipe connected with the three way valve with a spanner 3 Unscrew the spool of the two way valve by 90 with an inner hexagon spanner and after about 10 seconds close the two way valve then air will be drained out from the mouth of the thick pipe When the air is drained out screw tightly the nut on the mouth according to there quired torque 4 Open the two way valve and three way valve with an inner hexagon spanner 5 Check the leakage with soap liquid or a leakage checker 6 Screw tightly the two valve caps according to the required torque Liquid Side Two way Valve 9 6 35mm 1 4 c 9 52mm 3 8 Gas Side 1 mm 1 2 Mouth Nut Three way Valve et AG Required Torque Torque Tight screw N M Specif Valve Spool 7 9 Valve Cap 20 25 When the connection pipe is more than 5 cm it shall be filled with refrigerant as per the following form Pipe Length 5m 7m 10m 15m Refrigerant filled none 32g 80g 160g Notes When the pipeis extended the air in the connection pipe shall be drained out with the refrigerant R22 from outside the system then the excess refrigerant shall be drained out as per the air drainage method Check the Layout of the Drain Pipe and Connection Wires The drain pipe should be placed underneath and the connection
32. wires should be placed upside and the drain pipe especially the section inside the machine and indoors must be wound up with insulating material to preserve heat The drain pipe shall be sloped and no concave and convex shall occur along the whole pipe And the cases as the right drawing indicates P not occur 7 g Jes SlL g Qi Prohibited Prohibited Prohibited 2a Correct Up bent End in the Water Ripple Bad Smell in the Pool 29 Installation 4 Piping Connection for Indoor Unit Insert the auxiliary hoses liquid hose and gas hose and the unit connection wires through the wall hole from outdoor side and connect the pipes and wires as per the method of piping connection or insert the auxiliary hoses liquid hose and gas hose and the connection wires as a whole through the wall hole from indoor side for connecting the outdoor unit after connection of the auxiliary hoses and unit connection wires 5 Install and Fix Hang the indoor wall unit on the fastener of the mounting plate and move the unit left and right to check the firmness Hold the two sides of the unit with two hands to press the unit y yt to the mounting plate until a sound kacha is heard Piping Protective Cover Installation of Outdoor Unit 1 Install and Fix Fix the outdoor support on the wall with M10 expansion screws then screw tightly the outdoor unit on the support with M10 bolts and nuts and leveled If it is installed on wa