GE ZV800 User's Manual

image

Contents

1. Install original top screws If there is a noticeable gap between the hood and the bottom of the cabinet on the sides e Slide canopy forward and install original top screws through the bottom of the hood and into cabinet bottom or frame NOTE Install wood filler blocks if necessary to accept the screws Installation Instructions UNDER CABINET INSTALLATION 8 CONNECT ELECTRICAL WARNING house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors ADVERTISSEMENT Si la maison n est pas cablee avec deux fils et un fil de terre l installateur doit installer un fil de terre Quand les fils sont en aluminium il faut prendre soin d utiliser des connecteurs aluminium cuivre avec une pate antioxydante approuv e par ULL e Remove junction box cover and knockout e Use a conduit connector to secure the conduit to the junction box e Connect white leads to branch circuit white lead e Connect black leads to branch circuit black lead e Connect green yellow leads to branch circuit green lead or bare ground lead e Secure all connections with wire nuts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched e Secure electrical panel cover with screws provided
2. e Install both metal grease filters e To remove the filters press inwards on the handle and pull the filter downwards 18 Installation Instructions UNDER CABINET INSTALLATION CABINET REQUIREMENTS This hood may be installed beneath a wall mounted cabinet e f the cabinet has been installed it must be removed so that wall framing supports can be added 24 Min y The cabinet must be at least 20 high between the bottom frame and the inside top If the cabinet is not 20 from bottom to inside top a custom cabinet or modifications to a different size cabinet and or soffit may be required to accommodate the hood housing e The cabinet must be 36 wide and at least 12 deep e The cabinet must be firmly secured to wall studs or the added framing support and capable of supporting 100 pounds DUCTWORK WIRING e Determine the exact location of the vent hood e Locate the Rear Wall Template packed with the literature e Measure 36 from the floor to the top of the cooking surface Add the pre determined hood installation height Mark that location e Use a level to draw a straight pencil line on the wall O 3 3 4 centerline to wall L ceiling Top frame mounting screw locations 04300000 e Tape the template in position along the penciled line Check to be sure the template is level e Use the level
3. INSTALL REAR MOUNTING SCREWS Install 2 Wood Screws e Pull the glass canopy forward to access and install 2 wood screws or fasteners through the bottom of the hood and into the wall 23 10 INSTALL FILTERS e Remove protective film on the filters NOTE It is not necessary to install the charcoal filter in a vented installation e Tip the filter into the slots at the rear of the opening Lift the filter lock and pull forward until the filter rests in the slots e Install both metal grease filters e To remove the filters press inwards on the handle and pull the filter downwards Pub No 49 80267 10 04 JR Printed in Italy NOTE While performing installations described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Monogram GE Consumer amp Industrial Louisville KY 40225 2004 GE Company
4. Electrical supply These vent hoods must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e f the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Use metal ductwork only These hoods must use 6 round duct It can transition to 3 1 4 x 12 reducing the maximum equivalent duct length to 75 feet e Install a wall cap with damper or roof cap at the exterior opening Order the wall or roof cap and any transition needed in advance Wall Framing for Adequate Support e This vent hood is heavy Adequate structural support must be provided in all types of installations The hood must be secured to vertical studs in the wall or to a horizontal support For wall mounting installations see pages 9 and 14 For under cabinet installations see page 20 e The vent hood and wall cabinet if used should be on site before final framing and wall finishing This will also help to accurately locate the duct work and electrical service e Route house wiring through conduit as close to the installation location as possible in the ceiling or back wall e Use a conduit connector to secure the conduit to the junction box e Connect the wiring to the house wiring in accordance with local codes Grounding instructions The ground
5. a wood screw on each side of the mounting frame e Lift the hood onto the mounting bracket e Check to be sure it is level e Install wood screws through the hood and into the wall on each side of the mounting bracket Install bottom mounting screws e Extend the canopy forward for better access to the rear mounting screw holes e Install 2 wood screws or fasteners through the bottom of the hood into the wall Installation Instructions WALL MOUNTED INSTALLATION VENTED TO THE OUTSIDE 6 CONNECT DUCTWORK e Install ductwork making connections in direction of airflow as illustrated e Push duct over the exhaust outlet and damper e Secure joints in ductwork with sheetmetal screws e Wrap all duct joints with duct tape for an airtight seal e Use duct tape to seal the flange connections CAUTIONS no not use sheet metal screws at the hood flange connection Doing so will prevent proper damper operations Seal connection with tape only CONNECT ELECTRICAL Verify that power is turned off at the source WARNING i house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors ADVERTISSEMENT Si la maison n est pas cablee avec deux fils et un fil de terre l installateur doit installer un fil de terre Quand les fils sont en aluminium il faut
6. measure at least 20 from the bottom frame to the inside top The hood housing will occupy the interior cabinet space Wall Mount ZV800 Installation Heights Actual Possible Celing Possible VENTED RECIRCULATING Height Installation Height Installation Height 711 24 to 27 to 25 8 0 24 to 28 to 26 g1 24 to 30 to 27 8 2 24 to 30 to 28 8 3 24 to 30 to 29 8 4 24 to 30 to 30 8 5 24 to 30 to 30 8 6 24 to 30 to 30 87 24 to 30 to 30 8 8 24 to 30 to 30 8 9 24 to 30 to 30 8 10 24 to 30 to 30 8 11 24 to 30 to 30 9 0 24 to 30 to 30 g1 24 to 30 to 30 9 2 24 to 30 to 30 g3 24 to 30 to 30 g4 24 to 30 to 30 9 5 24 to 30 to 30 9 6 24 to 30 to 30 97 25 to 30 to 30 9 8 26 to 30 to 30 9 9 27 to 30 to 30 9 10 28 to 30 to 30 9 11 29 to 30 to 30 10 to 30 Based on 36 countertop height INSTALLATION BELOW A WALL CABINET Order a cabinet that is at least 20 high from the bottom frame to the inside top The cabinet must be at least 12 deep e The hood installation height is determined by the ceiling height e The hood installation heigh
7. prendre soin d utiliser des connecteurs aluminium a cuivre avec une pate antioxydante approuv e par ULL 12 Air flow Duct tape over seam and screw PRUDENCE Il ne faut pas utiliser de vis autoraurdeuses a la connexion du collet de la hotte Ceci emp cherait le bon fonctionnement du registre N utiliser que du ruban adh sif pour assurer l tanch it du raccord e Remove junction box cover and knockout e Use a conduit connector to secure the conduit to the junction box e Connect white leads to branch circuit white lead e Connect black leads to branch circuit black lead e Connect green yellow leads to branch circuit green lead or bare ground lead e Secure all connections with wire nuts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched e Secure electrical panel cover with original screws Installation Instructions WALL MOUNTED INSTALLATION VENTED TO THE OUTSIDE 8 INSTALL DUCT COVERS e Place the decorative duct covers on top of the hood NOTE The inside upper duct piece has holes on one end The holes are intended for use when the hood is installed for recirculating purposes Slide the vented end into the outer piece the vent holes should not be visible in this installation The inside duct piece must slip into the folded ends of the outer section Install 2 screws duct cover
8. to draw a line straight up from the centerline on the template to the ceiling e Measure 3 3 4 from the back wall to the centerline of a 6 1 2 hole on the ceiling NOTE If drywall is not present add drywall thickness to the 3 3 4 dimension HOUSE WIRING LOCATION e The junction box is located on the top right side of the hood e Wiring should enter the back wall 20 to 26 above the bottom of the hood and within 4 of the right side of the centerline Wiring should enter at least 4 above the right side of the frame Installation Instructions UNDER CABINET INSTALLATION INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT Framing must be capable of View from rear cleats 1 x 6 min mounting support Centerline of installation space If drywall is present mark the screw hole locations for the top mounting brackets Remove the template e Cut away enough drywall to expose 2 vertical studs at the bracket location indicated on the template e Install a horizontal support at least 1 x 6 between two wall studs at the top bracket installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs e Reinstall drywall 20 2 PREPARE THE HOOD e Remove the hood from the box Remove packaging and tape Remove 2 side Electrical cover screws e Remo
9. 8 pilot holes at the 6 punched locations e Remove the template e The 2 holes in the support bracket holes must enter studs or the horizontal support e Use wood screws to secure the mounting bracket to the wall The screws must engage wall studs or the installed horizontal mounting support e Check to be sure that the bracket is level There is no way to level the hood after hanging it from this bracket 15 3 PREPARE THE HOOD e Remove the hood from the box Remove packaging and tape Remove 2 side cover screws Electrical e Remove one screw on each side of the cover on the electrical panel Lift off the cover and set aside with screws Junction box Inside screw Secure electrical panel with 3 screws e Stand the electrical panel upright e Align the screw holes in the bottom of the panel with the holes on the base of the hood at the front side e Install 3 screws provided e Snap the damper into the exhaust outlet on the top of the hood Install Installation Instructions WALL MOUNTED INSTALLATION RECIRCULATING 4 MOUNT THE HOOD Install a wood screw on each side of the mounting frame Mounting bracket __ _ Z pS e Lift the hood onto the mounting bracket e Check to be sure it is level e Install wood screws through the hood and into the wall on each side of the mounting bracket Install bottom mounting screws e E
10. D SUPPORT IM PORTANT Framing must be capable of supporting 100 Ibs 6 min opening for ductwork View from rear cleats 1 x 6 min mounting support 4 4 VS 4 EG Centerline of installation space If drywall is present mark the screw hole locations for the top mounting brackets Remove the template e Cut away enough drywall to expose 2 vertical studs at the bracket location indicated on the template e Install a horizontal support at least 1 x 6 between two wall studs at the top bracket installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs e Reinstall drywall Installation Instructions WALL MOUNTED INSTALLATION VENTED TO THE OUTSIDE 2 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs e With the template taped in place use a punch to mark all mounting screw locations e Drill 1 8 pilot holes at the 6 punched locations e Remove the template e The 2 holes in the support bracket holes must enter studs or the horizontal support e Use wood screws to secure the mounting bracket to the wall The screws must engage wall studs or the installed horizontal mounting support e Check to be sure that the bracket is level There is no way to level the hood after hanging it from th
11. Installation Instructions If you have questions call 800 626 2000 or visit our website at www monogram com 36 Chimney Vent Hood ZV800 Monogram Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully s IM PORTANT Save these instructions for local inspector s use s IMPORTANT Observe all governing codes and ordinances e Note to Installer Be sure to leave these instructions with the Consumer e Note to Consumer Keep these instructions with your Owner s Manual for future reference e Skill Level Installation of this appliance requires basic mechanical and electrical skills e Completion Time 1 to 3 Hours e Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the warranty For Monogram local service in your area 1 800 444 1845 For Monogram service in Canada 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION PRUDENCE A cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et de dommages IL FAUT DEUX PERSONNES POUR FAIRE LINSTALLATION CORRECTEMENT WARNING To reduce the risk of fire or electrical shock do not use this range hood with any ext
12. TH PENCIL LINE INDICATING BOTTOM OF THE HOOD e Tape the template in position along the penciled line CHECK TO BE SURE THE TEMPLATE IS LEVEL e Use a level to draw a line straight up from the centerline on the template to the ceiling HOUSE WIRING LOCATION e The junction box is located on the top right side of the hood e Wiring should enter the back wall 20 to 26 above the bottom of the hood and within 4 of the right side of the centerline INSTALL FRAMING FOR HOOD SUPPORT IM PORTANT Framing must be capable of View from rear cleats 1 x6 min mounting support Centerline of installation space If drywall is present mark the screw hole locations for the top mounting brackets Remove the template e Cut away enough drywall to expose 2 vertical studs at the bracket location indicated on the template e Install a horizontal support at least 1 x 6 between two wall studs at the top bracket installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs e Reinstall drywall 14 Installation Instructions WALL MOUNTED INSTALLATION RECIRCULATING 2 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs e With the template taped in place use a punch to mark all mounting screw locations e Drill 1
13. ad e Connect green yellow leads to branch circuit green lead or bare ground lead e Secure all connections with wire nuts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched e Secure electrical panel cover with original screws Om Install 2 screws duct cover and into ceiling bracket NO ca instal NE OA 2 bottom duct cover screws e Extend the inner duct piece upwards to the ceiling mounted air deflector e Secure the duct cover to the air deflector driving one screw on each side e Locate the screw holes on the bottom outside edge of the hood e Secure the lower duct cover to the hood by installing 2 screws from the bottom of the hood into the duct cover Installation Instructions WALL MOUNTED INSTALLATION RECIRCULATING 8 INSTALL FILTERS 9 FINALIZE INSTALLATION e Remove all packaging materials e Refer to the Owner s Manual for operating instructions Charcoal filter e Remove protective film on the filters e Install the black charcoal filter into the center opening Metal grease filters e Tip filters into the slots at the rear of the opening Lift the filter lock and pull forward until the filter rests in the slots
14. and into ceiling bracket Install 2 bottom duct cover screws e Extend the inner duct upwards to the ceiling bracket e Secure duct cover to ceiling bracket with 2 screws e Secure the lower duct cover to the hood by installing 2 screws from the bottom of the hood into the duct cover 13 9 INSTALL FILTERS e Remove protective film on the filters Filter Locks NOTE The charcoal filter is not required for this installation e Tip the filter into the slots at the rear of the opening Lift the filter lock and pull forward until the filter rests in the slots e Install both metal grease filters e To remove the filters press inwards on the handle and pull the filter downwards 10 FINALIZE INSTALLATION e Remove all packaging materials e Refer to the Owner s Manual for operating instructions Installation Instructions WALL MOUNTED INSTALLATION RECIRCULATING DUCTWORK WIRING LOCATIONS e Determine the exact location of the vent hood e Locate the template packed with the literature e Measure 36 from the floor to the top of the cooking surface Add hood installation height determined on page 7 Mark that location L ceiling 04300000 ALIGN BOTTOM EDGE WI
15. cter le rabat de la hotte En utilisant des vis vous emp chez le bon fonctionnement du volet de fermeture Scellez la connection uniquement avec du ruban adh sif Installation Instructions WALL MOUNTED INSTALLATION RECIRCULATING 6 CONNECT ELECTRICAL Verify that power is turned off at the source WARNING i house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors ADVERTISSEMENT Si la maison n est pas cablee avec deux fils et un fil de terre l installateur doit installer un fil de terre Quand les fils sont en aluminium il faut prendre soin d utiliser des connecteurs aluminium cuivre avec une pate antioxydante approuv e par ULL INSTALL DUCT COVERS e Place the decorative duct covers on top of the hood NOTE The inside piece has holes on one end intended for use when the hood is installed for recirculating purposes Be sure the vented end is at the top the vent holes will be visible in this installation Mounting screw holes Vent holes The inside duct piece must slip into the folded ends on the outer section e Remove junction box cover and knockout e Use a conduit connector to secure the conduit to the junction box e Connect white leads to branch circuit white lead e Connect black leads to branch circuit black le
16. e 36 from the floor to the top of the cooking surface Add hood installation height determined on page 7 Mark that location Use a level to draw a straight pencil line on the wall 3 3 4 centerline to wall gt FOR CEILING VENT DUCTING Ceiling 6 1 2 dia hole Centerline 3 3 4 min above top mounting bracket o FOR WALL VENT DUCT N 04300000 Tape the template in position along the penciled line CHECK TO BE SURE THE TEMPLATE IS LEVEL Ceiling ducting If ductwork will vent straight up to the ceiling e Use a level to draw a line straight up from the centerline on the template to the ceiling e Measure 3 3 4 from the back wall to the centerline of a 6 1 2 hole on the ceiling NOTE If drywall is not present add drywall thickness to the 3 3 4 dimension Wall Ducting If ductwork will vent to the rear e Use a level to draw a line straight up from the centerline on the template e Measure at least 3 3 4 above the top mounting bracket holes shown on the template to the centerline of a 6 1 2 dia duct hole Hole may be elongated for duct elbow HOUSE WIRING LOCATION e The junction box is located on the top right side of the hood e Wiring should enter the back wall 20 to 26 above the bottom of the hood and within 4 of the right side of the centerline Wiring should enter at least 4 above the bracket on the right side INSTALL FRAMING FOR HOO
17. e panneau du disconcteur attacher un placard ou une tiquette tr s visible au panneau For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors Structural framing installation work and electrical wiring must be done by qualified person s In accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Local codes vary Installation electrical connections and grounding must comply with applicable codes In the absence of local codes the vent should be installed in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PRUDENCE Il faut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouvoir vacuer l air correctement Il ne faut pas vacuer l air correctement II ne faut pas vacue
18. ernal solid state speed control device Any such alteration from original factory wiring could result in damage to the unit and or create an electrical safety hazard ADVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique il ne faut pas utiliser cette hotte avec un r gulateur de vitesse lectronique externe Toute modification de ce type du branchement d usine peute endommager l appareil ou cr er un risque de choc lectrique TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARN l NG TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at the service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel ADVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet appareil uniquement de la mani re pr vue par le fabricant En cas de question consulter le fabricant Avant toute intervention ou nettoyage couper l alimentation lectrique au disjoncteur et verrouiller le panneau du disjoncteur pour viter la mise sous tension accidentelle S il n est pas possible de verrouiller l
19. glasses 3 8 Bits O Duct tape O Tape to mount template i O Gloves to protect against sharp edges ST Caan E 120V 60Hz 15 or 20 Amp 2 wire with Duct Tape SEBS ground Properly grounded branch circuit O Strain relief for junction cover O 6 round metal duct length to suit installation Ee Hammer O Saw or jig saw Strain relief for Phillips Flat blade O pe He house wiring junction cover head Serewdriver and conduit connector serewdriv r G0 N Saw or jig saw Wire nuts Masking tape Conduit Spirit level Safety glasses REMOVE THE PACKAGING 2 piece duct cover e Remove the duct cover parts box and other e Lift the hood out of the box packaging e Remove and properly discard the plastic wrapping e Remove junction box cover Installation Preparation WALL MOUNT INSTALLATIONS These hoods may be installed onto a wall or below a wall cabinet e Telescopic duct covers are provided to conceal the ductwork running to the ceiling e This hood can be installed for recirculating operation No kits required The vent hood must be installed 24 min and 30 max above the cooking surface The hood installation height from the cooking surface to the bottom of the hood depends upon ceiling height INSTALLATION BELOW A CABINET B AE 24 Min y The cabinet must
20. ing conductor must be connected to a ground metal permanent wiring system or an equipment grounding terminal or lead on the hood WARNING The improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVERTISSEMENT Le mauvais branchement du fil de mise la terre peut causer un choc lectrique En cas de doute consulter un lectricien qualifi ou un technicien pour d terminer si l appareil est a la terre Installation Preparation DUCT FITTINGS Use this chart to compute maximum permissable lengths for duct runs to outdoors NOTE Do not exceed maximum permissable equivalent lengths Maximum duct length 100 foot for 6 round duct 75 foot for 3 1 4 x 12 duct Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible DO NOT use flexible plastic ducting NOTE Any home ventilation system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guideline
21. is bracket 10 3 INSTALL DUCT BRACKET The duct bracket must be intalled against the ceiling This bracket will hold the duct cover in place at the top Secure the bracket to the ceiling and wall e Align the marked centerline on the bracket with the centerline on the wall e Mark the 2 screw hole locations in the ceiling e Drill 1 8 plot holes in the marked locations e f pilot holes do not enter studs enlarge the holes to 3 8 and install wall fastener anchors e Drive screws by hand into the fasteners to allow anchors to expand Remove the screws e Secure the bracket to the ceiling and wall with wood screws and or fasteners Installation Instructions WALL MOUNTED INSTALLATION VENTED TO THE OUTSIDE 4 PREPARE THE HOOD e Remove the hood from the box Remove packaging and tape Remove 2 side Electrical cover screws panel e Remove one screw on each side of the cover on the electrical panel Lift off the cover and set aside with screws Junction box Inside screw Secure electrical panel with 3 screws e Stand the electrical panel upright e Align the screw holes in the bottom of the panel with the holes on the base of the hood at the front side e Install 3 screws provided e Snap the damper into the exhaust outlet on the top of the hood Install damper 11 5 MOUNT THE HOOD Mounting bracket Install
22. nted Installation Recirculating Ductwork Wiring Locations Step 1 Install Framing for Hood Support Step 2 Install Mounting Bracket Step 3 Prepare the Hood Step 4 Mount the Hood Step 5 Size and Cut Duct Piece Step 6 Connect Electrical Step 7 Install Duct Covers Step 8 Install Filters Step 9 Finalize Installation Under Cabinet Installation Cabinet Requirements Ductwork Wiring Step 1 Install Framing for Hood Support Step 2 Prepare the Hood Step 3 Cut the Opening Step 4 Install Side L Brackets Step 5 Remove Side Screw Step 6 Mount the Hood Step 7 Complete Installation and Connect Ductwork Step 8 Connect Electrical Step 9 Install Rear Mounting Screws Step 10 Install Filters INSTALLATION OPTIONS T 24 Min 30 Max y WALL MOUNTED INSTALLATIONS This hood may be installed onto a wall and vented to the outdoors or it can be installed for recirculating operation All necessary parts for a recirculating operation are shipped with the hood No kits required T 24 Min y Depending on Cabinet Height UNDER CABINET INSTALLATIONS The hood may be installed beneath a cabinet The cabinet must measure at least 20 from the bottom frame to the inside top See page 19 e Both vented and recirculating operation can be accomplished in an under cabinet installation Custom cabinet m
23. odification is required for recirculating operation Installation Preparation ADVANCE PLANNING e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 100 ft equivalent length for any duct configurations e Refer to Duct Fittings chart to compute the maximum permissible length for duct runs to the outdoors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PRUDENCE iitaut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouvoir vacuer l air correctement Il ne faut pas vacuer l air correctement Il ne faut pas vacuer l air dans l espace entre les parois d un mur un plafond ou un grenier un espace sanitaire ou un garage POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ADVERTISSEMENT POUR DES RAISONS DE SECURITE CET APPAREIL DOIT ETRE CORRECTEMENT MIS A LA TERRE Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances
24. ood IMPORTANT If filler blocks are not used the hood may not be secured to the cabinet 21 4 INSTALL SIDE L BRACKETS i i Install 2 screws in each bracket e Install the L brackets onto each side of the cutout The wide flat portion should be on top of the opening Install 2 screws into the top of each bracket 5 REMOVE SIDE SCREW The top center screw on both sides of the hood can be used to close up any noticeable gaps at the outside edges See illustration Remove screw cover and screw e Remove the center screw cover and screw on each side as shown Installation Instructions UNDER CABINET INSTALLATION 6 MOUNT THE HOOD Install a wood screw on each side of the mounting frame e Carefully lift the hood into the cabinet Guide the hood upwards to meet the ductwork IMPORTANT One person must hold the hood in place while the other drives the screws into the mounting frame 22 COMPLETE THE INSTALLATION AND CONNECT DUCTWORK Install 2 Screws into Each Side Bracket e Drive 2 screws into each side bracket Be sure the screws engage the filler blocks or the cabinet bottom e Pull the glass canopy forward to access and install 2 screws through the hood and into the brackets on both sides e Use duct tape to secure the duct to the exhaust outlet in the top of the hood Do not use screws at this location
25. r l air dans l espace entre les parois d un mur un plafond ou un grenier un espace sanitaire ou un garage Design Information CONTENTS Design Information Product Dimensions and Clearances Installation Options Advance Planning Ductwork Framing Power Supply Duct Fittings Installation Preparation Tools and Materials Required Remove the Packaging Wall Mount Installations Installation Below a Wall Cabinet Check Installation Hardware Ductwork Wiring Locations Wall Mounted Installation Vented to the Outside Step 1 Install Framing for Hood Support Step 2 Install Mounting Bracket Step 3 Install Duct Bracket Step 4 Prepare the Hood Step 5 Mount the Hood Step 6 Connect Ductwork Step 7 Connect Electrical Step 8 Install Duct Covers Step 9 Install Filters Step 10 Finalize Installation PRODUCT DIMENSION AND CLEARANCE NOTE The vent hood canopy extends forward 5 7 8 Height to Ceiling 35 7 8 12 15 16 at Sides 13 11 16 at Center The Supplied Duct Cover Fits 8 ft to 10 ft Ceiling Heights The vent hood must be installed 24 min and 30 max above the cooking surface The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling The duct cover is sized to reach 8 ft to 10 ft ceiling heights The hood installation height from the cooking surface to the bottom of the hood depends upon ceiling height Wall Mou
26. s and safety standards such as those published by NFPA and ASHRAE This Hood Must Use a 6 Round Duct It Can Transition To 3 1 4 x 12 Duct Dimensions Round straight Duct Piece 3 1 4 x 12 3 1 4 x 24 straight 6 Round 90 elbow 6 Round 45 elbow 3 14 x 12 90 elbow 3 1 4 x 12 45 elbow 3 1 4 x 12 90 flat elbow 6 round to 3 1 4 x 12 or 3 1 4 x 24 transition 3 1 4 x 12 to 6 round transition 6 round to 3 1 4 x 12 or transition 90 elbow 3 1 4 x 12 to 6 round round transition 90 elbow 6 round wall cap with damper 3 1 4 x 12 wall cap with damper 6 Round roof cap 6 Round roof vent Actual length of straight duct plus duct fitting equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood Total Equivalent Length Equivalent Length 1 ft per foot length Quantity Used 1 ft per foot length 15 ft 8 ft Total Duct Run Installation Preparation TOOLS AND MATERIALS REQUIRED NOT SUPPLIED O Tape measure O Knife O Spirit level Measuring Tape O Wire cutter stripper O Wire nuts O Electric drill with 1 8 and 3 8 bits n O Phillips and flat blade screwdrivers DE Ve te Pliers Electric drill o Pli n with 1 8 and O Safety
27. t must be 24 Min above the cooking surface wo Q Installation Preparation CHECK INSTALLATION HARDWARE Locate the hardware accessory box packed with the hood and check contents 4 wood screws 4 wall fasteners Air deflector for Duct bracket recirculating installations only 12 Pes Discharge damper Mounting bracket i UN ZEN et 1 charcoal filter for recirculating installations 3 Phillips head screws to secure electrical box to A top of motor SS compartment MS 11 172 2 piece decorative duct cover dimension shown for reference only 4 Phillips head decorative screws to secure duct cover to ceiling bracket 04302128 THIS EDGE AGAINST REAR WALL L Brackets with hardware package for cabinet mounted installations 4mxormm O2 42C08 4mxorme O2 42008 CUT OUT pe PORTION i REAR WALL TEMPLATE Contains 10 Phillips head screws to secure the brackets to the R cabinet 8 required 2 extra Sie n ss i Ssa ef 5 ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING she i BOTTOM OF THE HOOD 04302127 K Cabinet installation template Wall mount template Installation Instructions WALL MOUNTED INSTALLATION VENTED TO THE OUTSIDE DUCTWORK WIRING LOCATIONS Determine the exact location of the vent hood e Locate the template packed with the literature Measur
28. ve one screw on each side of the cover on the electrical panel Lift off the cover and set aside with screws Junction box Inside screw Secure electrical panel with 3 screws e Stand the electrical panel upright e Align the screw holes in the bottom of the panel with the holes on the base of the hood at the front side e Install 3 screws provided e Snap the damper into the exhaust outlet on the top of the hood Install damper Installation Instructions UNDER CABINET INSTALLATION 3 CUT THE OPENING If the cabinet has been installed remove it from the wall e Use the Top Cabinet Template to locate and cut a hole in the bottom of the cabinet e If necessary place the template on top of the cabinet to accurately cut a matching hole e Install the cabinet onto the wall The cabinet must be firmly secured to the wall and be capable of supporting 100 Ibs INSTALL WOOD BLOCKS IF NECESSARY e Install filler blocks whenever the cabinet frame hangs below the cabinet bottom e Install filler blocks whenever the cabinet bottom is less than 3 4 thick e Install the filler blocks on each side of the cutout The filler blocks will accept the hood mounting screws NOTE Additional filler blocks may be required along the outside edges to accept the outside screws See Step 5 Cabinet Frame Cabinet Bottom Shelf Filler Block Equivalent to Depth of Cabinet Recess Top of Vent H
29. xtend the canopy forward for better access to the rear mounting screw holes e Install 2 wood screws or fasteners through the bottom of the hood into the wall 5 SIZE AND CUT DUCT PIECE e Hold upper air deflector with duct connector against the ceiling e Measure from the bottom of the air deflector to the top of the hood as shown Reduce that dimension by 1 to facilitate installation The duct will cover O AN and overlap the Duct length deflector and the Measure hood outlets 16 5 SIZE AND CUT DUCT PIECE cont e Cut the duct piece to size and slip onto the bottom of the duct connector e Use duct tape to seal and secure the duct piece to the connector e Place the assembly over the hood outlet e Hold the assembly against the ceiling The penciled centerline should show through the slot in the deflector Mark the screw holes on the sides of the assembly e Remove the assembly and drill 1 8 pilot holes into the wall studs e Enlarge holes that did not enter studs to 3 8 and tap plastic or metal anchors into the holes flush with the wall e Mount the assembly onto the hood outlet push up against the ceiling and install the screws provided CAUTION Do not use sheet metal screws at the hood flange connection Doing so will prevent proper damper operations Seal connection with tape only ATTENTION vn utiisez pas de vis autotaraudeuses pour conne