1. Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must be in accordance with the National Electrical Codes ANSI NFPA 70 1999 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes
2. 6 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Mount blade flanges to fan blades rib line facing up using three M5 x 6 washer head screws Figure 5 A WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades M5 x 6 WASHER HEAD SCREW 3 _ RIB LINE THIS SIDE OF BLADE UP I 8 Turn the fan motor assembly upside down in preparation for mounting the fan blade assemblies NOTE Remove and discard the five shipping spacers and screws from the motor hub NOTE Take care not to scratch fan housing when installing blades 9 Loosely attach one blade assembly to the motor hub using two M6 x 14 flange screws with lock washers preassembled in flange Figure 6 Make sure the screws are NOT tightened Repeat this procedure for the other four blade assemblies The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat p
3. label You should record this data above and keep it in a safe place for future use THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES PATIOS AND DECKS This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder One 1 4 blade screwdriver One wire stripper One 5 16 open end wrench or pliers Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is com pleted place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this
4. must be grounded for safe operation C 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire con nectors supplied Figure 13 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 14 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 14 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring A WARNING CEILING COVER This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces sories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 13 Secure
5. the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Maintenance Abrasive cleaning agents are not required and should be avoided to prevent damage to finish IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed A WARNING When cleaning use only a soft brush or lint free cloth s 2 Do not use water when cleaning your ceiling fan It to avoid scratching the finish gy g could damage the motor or the blades and create the possibility of an electrical shock Accessories A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Elec
6. EMBLY EEE BRACKET SWITCH __ HOUSING A ASSEMBLY WITH C RUBBER COVER HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET SWITCH HOUSING ASSEMBLY FAN BLADES How to Put Your Ceiling Fan Together 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 5 PIN HANGER BALL DOWNROD Figure 1 2 Unscrew the setscrew Figure 2 until it clears the inside of the motor coupling Then separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed A WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tight ened F
7. LIED WITH OUTLET BOX HANGER BRACKET Figure 11 TAB 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 12 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 11 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard NOTE CEILING COVER an SUPPLY WIRES AND we Oty FAN WIRES OMITTED ees i N Sa FOR CLARITY aN HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY A WARNING To avoid possible fire or shock do not pinch wires Figure 12 between the hanger ball downrod assembly and hanger bracket How to Wire Your Ceiling Fan A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket Figure 13 To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it
8. READ AND SAVE THESE INSTRUCTIONS EMERSON MARIOL PORTICO Wet Location Model No CF690C KOO CF6900RB00 Ceiling Fan Owner s Manual FX onara Net Weight 24 2 Lbs ENERGY STAR LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for thirty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COM PONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELEC
9. TRIC CO How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary ma
10. ailure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in the fan falling MOTOR COUPLING Figure 2 J3 Tighten the setscrew Figure 2 securely while pulling up on the downrod NOTE The setscrew must be properly installed as described above or fan wobble could result SETSCREW 4 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 3 CEILING COVER DOWNROD COUPLING COVER Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 4 WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are proper ly installed could result in the fan falling HANGER BALL ___ SETSCREW DOWNROD CEILING COVER Figure 4 Ne Ka
11. commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This product is suitable for use in wet locations when installed in a GFCI protection branch circuit WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not des ignated for use with this product by Emerson Eleciric Co could result in personal injury or property damage WARNING To Reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades DATE CODE The date code of this fan may be found on the box stamped in ink on a white
12. her operation Repair Parts Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER e NAME OF ITEM e PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 10 Repair Parts Listing Part Numbers Model No Model No Description CF690CKO0 CF6900RB00 Hanger Ball Assembly 761655 23 761655 32 Consisting of Hanger Bracket Hanger Ball Downrod _ Parts Bag Containing 763234 763234 1 Wire Connector 3 Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Pin Clevis Clip Hairpin Wood Pendant Coupling Screw Blade M5 x 6 Washer Head 16 Screw Flange M6 x 14 with Lockwasher 1 Ceiling Canopy 761504 19 761504 20 Coupling Cover 762463 2 762463 16 Bracket Switch Housing Assembly with Mounting Screws and 763237 763237 1 Rubber Cover 1 3 9 1 Flange set of 5 763173 CK 763173 ORB Switch Housing Assembly 763241 763241 1 Owner s Manual BP7331 BP7331 11 EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant e St Louis MO 63136 Part No F40BP73310000 Printed in China 10 06 Form No BP7331
13. ich attach the fan flanges to the motor are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off Some fan motors are sensitive to signals from Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method Tighten screws securely 3 Fan wobbles excessively Setscrew in motor coupling is not tightened securely Setscrew in the hanger ball downrod assembly is loose Screws securing fan blade flanges to motor are loose Fan blade flanges not seated properly Hanger bracket and or ceiling outlet box is not securely fastened Fan blades out of balance Raise coupling cover and tighten setscrew securely Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade flanges to the motor are tight Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoot
14. intenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Part No F40BP73310000 Form No BP7331 U L Model No CF690 A WARNING WARNING To avoid fire shock and serious personal injury follow these instructions
15. ly connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box SUPPLY BLACK AND BLUE NOTE CEILING COVER GROUND FANWIRES _ OMITTED FOR CLARITY ill a N D ae pai LISTED WIRE CONNECTOR 3 WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET WIRE GREEN WIRE BLACK SUPPLY HOT GROUND FROM ae HANGER BALL THREADED STUD 2 Figure 13 Figure 14 A WARNING LOCKWASHERS 2 THREADED STUD KNURLED KNOB To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 6 Cut the 3 speed switch pull chain to a desired length optional Connect the wood pendant supplied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupler to the end of the chain and allow the wooden pendant to fall down over the coupling Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling
16. n is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture A WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician How to Hang Your Ceiling Fan A WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 10 AM A AT LEAST 7 Figure 10 E PEPE FLOOR 7 A WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt Jt Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 11 A WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall OUTLET BOX TWO SCREWS SUPP
17. on the pull chain switch 3 All fans are shipped from the factory with the reversing switch positioned to the left circulate air downward If airflow is desired in opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch to the right position and turn fan on again The fan blades will turn in the opposite direction and reverse the airflow 4 The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows Three Speed 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF z REVERSING SPEED CONTROL gt SWITCH SWITCH PULL CHAIN Reverse Switch Information Season Rotation Direction Switch Position Summer Counter Clockwise Left Winter Clockwise Right Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Retailer for optional mounting accessories Using
18. product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration Fan motor assembly One switch housing assembly Five fan blades One ceiling cover Five blade flanges One hanger ball downrod assembly One hanger bracket One coupling cover One bracket switch housing assembly with 4 mounting screws and rubber cover One loose parts bag containing 1 Sixteen M5 x 6 washer head blade screws 2 One M6 x 14 flange screw with lockwasher 3 One wood pendant 4 One coupling 5 Three wire connectors 6 Two threaded studs za r oOa0 0M uu 7 Two lockwashers 8 Two knurled knobs 9 One clevis pin 10 One hairpin clip NOTE Place the parts from the loose parts bag in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly FAN MOTOR lt ASS
19. roperly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again Figure 5 10 ADAPTOR PLATE p REMOVE ONE SERRATED HEAD SCREW PA G N AX N MOTOR is ga er y RN M6 x 14 FLANGE SCREWS WITH A a ai PREASSEMBLED S Figure 6 11 Remove and retain one of the three serrated head screws from the adaptor plate Figure 6 Loosen the other two serrated head screws three or four turns Position the bracket switch housing assembly with rubber cover on the adaptor plate so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover Turn the bracket switch housing assembly with rubber cover clockwise and tighten both screws Figure 7 Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly with rubber cover 12 13 5 BRACKET SWITCH AA HOUSING ASSEMBLY WITH RUBBER COVER REINSTALL ONE SERRATED HEAD SCREW TIGHTEN TWO PAN HEAD SCREWS MOUNTING SCREWS 4 Figure 7 14 Engage the connector of the switch housing assembly with the motor connector Figure 8 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly Remove the four mounting screws from the bracket switch housing assembly wi
20. th rubber cover Figure 8 Position the switch housing assembly on the bracket switch housing assembly with rubber cover and secure using the four mounting screws Figure 9 NOTE Do not pinch wires between the switch housing assembly and the bracket switch housing assembly with rubber cover HOUSING ASSEMBLY WITH RUBBER COVER SWITCH HOUSING CONNECTOR 15 BRACKET SWITCH MOTOR CONNECTOR MOUNTING 2 SCREWS 4 gt SLOT FOR PULL S N e Chain SWITCH Figure 8 NOTE The switch housing assembly must be oriented so that the pull chain switch will fit into the rounded slot Figure 8 in the bracket switch housing assembly with rubber cover N MOUNTING Figure 9 SCREWS 4 16 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with out let box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box must be securely anchored and capa ble of withstanding a load of at least 50 pounds If your fa
21. tric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog 2 WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN TROUBLE Trouble Shooting PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start Fuse or circuit breaker blown Loose power line connections to the fan or loose switch wire connections in the switch housing Reversing switch in neutral position 1 Check main and branch circuit fuses or circuit breakers 2 Check line power connections to fan and switch wire connections in the switch housing WARNING Make sure main power is turned off Make sure reversing switch position is all the way to one side 2 Fan sounds noisy Blades not attached to fan Screws securing fan blade flanges to motor are loose Wire connectors inside switch housing rattling Motor noise caused by solid state variable speed control Screws holding blades to flanges are loose Attach blades to fan before operating Check to make sure the screws wh