1. Front Fixings Support Foot CARPETS For safety the heater must be positioned in the room so that there is at least 75mm 3 free air space all around it under windows ensure that curtains when drawn cannot touch or cover the heater casing In order to maintain stability it is essential that the heater be placed on a level surface and care should be taken to avoid irregular surfaces such as may result from carpets or tiled surrounds partially protruding under the heater The heater feet are designed to go underneath a carpet rather than standing on it this permits the weight to be taken on a firm base Carpet gripper should be removed from behind the heater feet BRICKS The heater casing and the heater storage bricks with which it must be fitted are delivered in separate packages The brick is common to all heaters packed in pairs The brick catalogue number is 791402015 7934 and 75772001 models have 8 bricks 7935 and 75772002 models have 12 bricks 7936 and 75772003 have 16 bricks First turn carton upside down Open bottom flaps on cartonThe corner fitments contain the fixing kit Stand the heater against the wall in its intended position Mark the position of the two outside corners of the wall bracket Carefully place the heater aside and remove the wall bracket from the heater by removing the screw at each end Reposition the bracket against the wall using the corner marks for alignment
2. NEwela a heating revolution from Creda TSR Supaslim Combi Combined Storage and Fan Heater Assembly Instruction Manual Model Nos 79348S 793588 7936858 Cat Nos TSRI2ZCW TSRIBCW TSR24CW Automatic 75772001S 757720025 757720035 TSRI2ACW TSRI8ACW TSR24ACW IMPORTANT NOTES It is important to read these instructions carefully and also note the information given on the heater itself As these particular instructions refer to the assembly and installation of a new heater they should be retained by the installer not left behind for the user as this would invite the dismantling and servicing by unqualified persons FOR THE USER there is a separate instruction leaflet explaining how the heater should best be operated Please see that this leaflet is left with the heater for the user s purposes THE HEATER MUST BE CONNECTED TO THE FIXED WIRING VIA A DOUBLE POLE ISOLATING SWITCH HAVING A CONTACT SEPARATION OF 3MM IN ALL POLES AND IN ACCORDANCE WITH THE 1 E REGULATIONS CURRENTLY IN FORCE AND IN ACCORDANCE WITH ANY LOCAL CODE OF PRACTICE THE INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN CABLE HAVING A MINIMUM T RATING OF 85 C MUST BE USED Heaters forming part of a comprehensive space heating system should be wired with their own separate circuit if however 1 or 2 heaters are installed as a starter system these may be connected to a 30 amp ring main provided that the instructions bel
3. Storage Heater Circuit Storage Elements 793685 4 757720035 793585 757720028 n 475772001 Combi Fan Heater Circuit TERGSPHAL BLOCK BROWN RED BLUE oI oy gt 1 2 Load Connection Alternative BROWN IRED ELEMENT ASSEMBLY WITH SAFETY CUT OUT OUTPUT THERMOSTAT UNRESTRICTED SUPPLY RESTRICTED SUPPLY MAINS TERMINALS IMPORTANT For earthing loosen the earth screws sufficiently to wrap the mains earth wire around it between flat washer and cup washer and retighten the earthing screw Both restricted and unrestricted supply wires must be connected to their respective earthing points Feed the mains cable through the appropriate cable clamp and make connections as marked on the heater Pull back any slack through the clamp and tighten clamping screw If mains connection is to be made from the left hand side at this point the mains lead must be secured to the base of the fan box by fixing the ties provided in the fixing kit through the holes along the rear of the fan box base CONNECTING THE SUPPLIES Charge Rated Period Charge 793488 amp 75772001S 7 hours 12kWh 793585 amp 757720025 7hours 18kWh 793688 amp 757720035 7 hours 24 kWh NOTE rating If load rating only is required the installer The fan heater element is factory set at full should move the black wire as indicated in the circuit diagram WARNING Remov
4. No Skirting Board Skirting Board iia only when the skirting board is of the modern slim type or there is no skirting board at all THE HEATER MUST STAND VERTICAL A clear space of at least 3 75mm must be left at either side of the heater and any projections or shelves must be at least 10 250mm above the heater casing Curtains must not be draped around or in contact with the casing A shelf unit is separately available for fitting above heaters T E Ie a Tae tsunamis oes The top panel and front panel are joined and should be removed as one assembly To do this remove the screws fixing the rear flange of the top panel and remove the screws along the bottom edge of the front panel Carefully swing out bottom of front panel and lif assembly clear of casing this operation also removes the control knobs under the flap Put assembly in a safe place to avoid damage to paint etc NOTE Removal of the lower front panel is only possible after the top and main front panel assembly has been removed First remove the two black screws situated on the lower front face then remove the four side screws The lower front panel will then pull forward clear of the heater ENSURE THAT THE CABLES ARE NOT TRAPPED UNDER THE HEATER LEGS RESTRICTED SUPPLY e UNRESTRICTED SUPPLY
5. well back as mentioned earlier and the insulation properly aligned there should be no bulging of this panel and no undue force necessary to fix it Refit the lower front panel by aligning the four side screws before refitting the fron face screws With the lower front panel in place the outer panel assembly can be Eoo i hooked over the rear panel top flange and the screws top and bottom replaced an tightened Take care not to trap wires or the thermostat capillary between the pane flanges Ensure all washers are replaced in their original positions Refit the control knobs under the lift up flap taking care to align the flat on each spindle PLEASE ENSURE THAT ALL POLYSTYRENE AND CARDBOARD PACKING PIECES HAVE BEEN REMOVED ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY WARNING When a new heater is run up to temperature the materials will produce a slight smell for the first few days these are normally harmless in a well ventilated room It is best to make these first overnight charges with the Input control knob 4 j at Maximum Caged birds young children and people with chest ailments are best kept out of the room for this first period l i SETTING THE CONTROLS The controls are located under the lockable flap at the right hand corner of the top panel To adjust the controls on the OUTPUT heater use a coin and engage it in the slot provided on the top a surface of
6. the knob AUTOMATIC CHARGING DEVICE AUTO SET Fitted only on ACW models The Auto Set Contro rations the overnight charge each night by sensing the room temperature The knob is marked with the numbers 1 to 6 turning the knob to a lower number will reduce the charge consequently the level of room warmth the next day Once set the knob should need no further adjustment and the Auto Set will maintain automatically the room warmth each day by varying the charge according to the weather 1 Set the room temperature output control knob to setting 4 2 Turn the Auto Set Knob clockwise as far as it will go 3 Leave the heater to run in this condition for two nights in order to quickly disperse the new smell which although slight is better removed once and for all 4 Instruct the user to set the Auto Set down to his chosen setting on the third day Instructions on this are given in the Users Guide which we ask you to ensure is left with the user MANUALLY ADJUSTED HEATER without Auto Set Control On this the user sets the overnight charge on the numbered knob marked Input Setting up procedure 1 Turn the Input knob to maximum setting 6 2 Set the Output knob to setting No 4 3 Leave the heater to run in this condition for two nights in order to quickly disperse the new smell 4 Instruct the user to set the Input to his chosen setting on the third day Instructions on this are given in
7. Mark through slots in bracket two at k il uy RA the extreme ends and the others spaced evenly between them ACW Models Only The Room Sensor is located at the rear of the right hand side of the heater Carefully slide the sensor plate down from its transit position to its operational position TRANSIT POSITION OPERATIONAL POSITION The slots are in groups allowing mortar courses between bricks to be avoided or battens etc to be found for the fixing holes CARPET FITTING Cut the underlay and remove carpet gripper to clear feet allowing heater weight to be taken on floor proper lay carpet over feet slitting it as shown above It is unnecessary to cut carpet away align screw holes on heaters ends There are two fixing slots at each end of heater allowing different stand offs for different thicknesses of skirting board Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur NOTE NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER See also figure 2 regarding carpets where appropriate Note Max skirting size is 15 x 120mm Note that the smallest wall spacing should be used When bracket is securely fixed replace the heater under the bracket angle and You must fit a retaining screw at ce each end of the T heater ial Inner Stot uter Shot as 180mm 6
8. e the inner front panel this carries on it s inner face the front insulation slab Handle this with care the insulation must not be damaged REMOVE ALL THE PACKING CARDBOARD FROM INSIDE THE STORAGE BRICK COMPARTMENT IF LEFT INSIDE IT WILL BE SET ON FIRE WHEN THE HEATER IS SWITCHED ON ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM Temporarily remove one central element to provide access for the rear rank of bricks Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage bricks On heaters with 3 or 4 elements remove one of the central ones Note the way the bricks are positioned in the heater Otherwise they will not fit Put in place the rear rank of bricks pushing them well back against the rear insulation Replace the element making sure that the connection is tight Now place in position the front rank of bricks again pushing them back to make room for the front insulation slab which is attached to the front panel ao Check that the front insulation slab is properly attached to the inner ee TN insul propery pe a Ta front panel and refit panel insulation innermost to the heater by locating its bottom edge behind the front lip ofthe chassis and inserting i retaining screws along the top and both sides With the bricks pushed
9. ed or moved from the wall bracket whilst it is loaded with bricks THE HEATER IS VERY HEAVY AND WILL BE DANGEROUS IF ITS WALL FIXING BECOMES INSECURE Solid Brick and Concrete Walls No 10 Rawlplug fibre inserts Check that the panel itself is adequately fixed to battens etc Use Rawlplug Drill hole of 5 5mm dia to a depth Lin the brick of 55mm M5 intersets drill accurate 10mm dia holes in single skin plasterboard One i fixing should be in studwork Timber Frame Hollow concrete Breeze Block and Thermolite Block Walls Seek specialist advice some authori _RAWLPLUG RAWLOK R6054R Some authorities suggest UNIFIX LB 70 ties suggest RAWLNUT 10mm Use Drill for accurate hole not hammer or chisel PLEASE DON T TAKE CHANCES Controls Under Flap i ean y Top Suter Site conditions may vary considerably and Creda cannot recommend the correct wall fixings to be used It is the responsibility of the installer to ensure that adequate permanent fixing has been achieved Purely for guidance the suggested fixings are made for certain wall materials but this list is not comprehensive or authoritative Different wall constructions will need different inserts Note that inserts incorporating plastic may be subject to shrinkage behind a warm storage heater and are therefore not recommended Front Panel Bottom Fixings Wall fixings can be obtained from local stockists Side cas Fixings
10. ow are observed any further heaters installed must be connected by its own circuit If connected to a 30 amp ring circuit the tota rating of heaters connected must not exceed 3kW where the circuit supplies a kitchen or 4kW where the circuit does not include a kitchen The storage radiator is designed to run on cheap overnight electricity therefore the means of connecting the heater to the ring main should include a timer These should be connected to the supply with 3 core heat resistant cable the size of which is dependant on heater loading i e loading up to 10 amps use Imm up to 13 amps use 1 5mm and for the larger heaters 2 5mm cable WARNINGS THIS APPLIANCE MUST BE EARTHED SPECIAL ATTENTION MUST BE PAID TO THE SECURITY OF THE HEATER S WALL FIXINGS THE HEATER MUST BE PLACED ON A LEVEL SURFACE AVOIDING ANY IRREGULARITIES Two supplies are taken into this heater both fan heater and storage heater circuits must be connected to the same phase of the electricity supply IF DURING ANY REASSEMBLY OF THE HEATER A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY IT SHOULD BE REPLACED BY AN IDENTICAL PART WALL FIXING The heater must ALWAYS be mounted against and fixed to a wall as it will not stand up by itself A detachable bracket is provided for screwing to the wall the heater is then placed in position and fixed to the bracket by a screw at each end The heater must never be unscrew
11. the Users Guide which we ask you to ensure is left with the user Part No 85901 Iss No 3 12 03