1. FIGURE 24 FIGURE 25 2004 IMI Cornelius Inc 5 Publication Number 729011146INS Door Latch Assembly Installation Instructions CC j C Remove cover from box D Locate the 2 pin plug that says SOLD OUT on the control board There will be one for each pump Disconnect these connectors There will be 4 total in a four flavor machine FIGURE 26 E Replace the connectors with the SOLD OUT jumpers FIGURE 28 THIS COMPLETES THE LATCH ASSEMBLY PROCEDURE for OPTION 2 SOLD OUT DISABLED OPTION disabling the sold out function Complete the procedure by replacing all machine covers and guards If machine does not function after reassembly make sure control box is properly seated in mating con nector Publication Number 729011146INS 6 2004 IMI Cornelius Inc
2. IMPORTANT Disconnect power from machine before starting this procedure 1 Remove the top cover of the machine A Remove two screws from rear of top B To remove cover open door and pull cover forward FIGURE 2 FIGURE 3 2 Remove the side panel of the machine A Remove latch cover plate B Remove 2 screws holding splash guard NOTE When reassembling latch guard use the 8 PLASTIC screws supplied FIGURE 5 FIGURE 4 C Remove one screw from lower rear on right D Slide panel forward to remove side panel NOTE Do not loose plastic spacers located on panel clips cee FIGURE 7 Publication Number 729011146INS 2 2004 IMI Cornelius Inc Door Latch Assembly Installation Instructions 3 Remove and replace door catch A Remove 2 8 32 screws holding existing B Replace catch with new catch assembly door catch Fasten to door with 8 32 x 5 8 screws FIGURE 8 FIGURE 9 4 Remove and replace cabinet catch A Pull back tape back exposing catch switch B Remove and save insulation putty to be rein stalled later nea 10 FIGURE 11 C Remove 2 6 32 screws holding existing D Remove latch switch from wire harness latch switch FIGURE 12 FIGURE 13 2004 IMI Cornelius Inc 3 Publication Number 729011146INS Door Latch Assembly Installation Instructions E Insert slotted holes into new latch F Attach bracket and latch to cabinet frame using 2 6 32 x 3 8 screws and
3. washers FIGURE 15 FIGURE 14 G Close door and adjust cabinet bracket using H Check lower and upper door to assure seal the 6 32 screws Door should slightly com If not adjust bracket until it properly seals press the door seal FIGURE 17 FIGURE 16 5 Connect cabinet interrupt switch jumper wire A Plug one end of black spade end jumper in B Wrap a piece of electrical tape on both ends each end of existing cable to prevent wires from coming loose M FIGURE 18 FIGURE 19 Publication Number 729011146INS 4 2004 IMI Cornelius Inc CC on elkus D Door Latch Assembly Installation Instructions C Route wires in existing cavity and reinstall insulation putty and replace tape E a my ry D Replace side panels by sliding panels for E Replace latch cover plate ward to engage panel tabs Make sure plas NOTE When reassembling latch guard use tic spacers are located on panel clips before the 8 PLASTIC screws supplied if holes are assembling Replace all screws that were stripped previously dissembled FIGURE 23 FIGURE 22 THIS COMPLETES THE LATCH ASSEMBLY PROCEDURE If the machine is to use OPTION 1 DOOR RESET OPTION allowing sold out to function complete the procedure by replacing all machine covers and guards IF OPTION 2 IS SELECTED CONTINUE WITH PROCEDURE 6 Installing sold out defeat jumpers A Remove screw holding electrical box to B Pull control box from machine frame
4. C Cinel D Door Latch Assembly Installation Instructions INSTALLATION INSTRUCTIONS REMOVAL AND INSTALLATION OF DOOR LATCH ASSEMBLY QUEST NOTE Removing the existing door catch switch with the replacement catch will remove the auto matic sold out reset function of the machine This feature can still be used or totally defeated depending on users preference OPTION 1 By removing the existing switch and not jumping the board the sold out will work but not reset unless the pump door switch is manually reset after each refill If the switch is not manually reset the light will not go out even after installing new product OPTION 2 To disable the sold out feature jumpers are added to the control board in the sold out plug location The sold out will now be disabled and never come on Installation of these options are described below Parts List Description Bracket Sold Out Jumper Board Jumper Switch Spacer Screw Plastic 8 x 34 Screw 6 32 x 3 8 Washer 145x 5x 03 Screw 6 32 x 1 4 Latch Catch Tools Required e Hex Screw Driver e Electrical Tape Revision Date June 30 2004 2004 IMI Cornelius Inc Part Number 720201471 11749 720302204 720705306 07015001 0700203 07301043 0700201 720532112 720202415 Qty FIGURE 1 pPNNDND Aa A www cornelius com Revision C sie Publication Number 729011146INS Door Latch Assembly Installation Instructions C Cinkius gt INSTALLATION

Download Pdf Manuals

image

Related Search

Related Contents

Gebrauchsanleitung Instruction manual Mode d`emploi Handleiding  Krabat Pirate  Sitecom USB 2.0 Extension Cable  ES / ACS150 User`s Manual with Update Notice  INSTRUCTION MANUAL FOR DISHWASHERS - Emga  Oki CX 1145 MFP User's Manual  Yamaha CL1 Rental Manual  初期設定サービス付きギフトパック  PINTURA ACRÍLICA PARA SEÑALIZACIÓN Y CAMPOS DE TENIS  Sika®Viscocrete 5 - Distribuciones Villamar  

Copyright © All rights reserved.
Failed to retrieve file