Home

Aga Ranges ACIM-15 User's Manual

image

Contents

1. Move the unit to an area where room temperature is below 90 F Ice machine is not level The selector switch is not in the ON position Use a level to check the unit for level from side to side and front to rear Set the rocker switch on the grille of the ice machine to the ON position The grid cutter is not plugged into the receptacle Remove the escutcheon panel and plug the grid cutter into the receptacle on the side of the line Time to cut through the slab It can take up to 35 minutes to cut through a harvested ice slab This is normal operation TROUBLESHOOTING FOUR PROBLEM POSSIBLE CAUSE Ice cubes are sticking together Ice consumption is low CORRECTION Use the ice in the bin frequently Ice will stick together if left in insulated bin over long periods of time Room temperature is too warm The ice machine is not level Ice level is too high Move the unit to an area where temperature is below 90 F Use a level to check the unit for level from side to side and front to rear Room temperature is too warm Move the unit to an area where temperature is below 90 F Ice deflector is not in place or secured properly Check to see that the ice deflector is in place and secured below the grid cutter Bin level sensing tube needs adjusted Ice level is too low The ice machine is not level You can adjust the bin level sensing tube by simply press
2. cook better eat better taste better live better Aga ACIM 15 Clear Ice Machine For models with serial number 20070608001 and higher Installation Operation amp Maintenance Instructions TABLE OF CONTENTS Starting Dti ita 3 Installation maan ads 4 Installation Drain Plumbing 5 Water Supply csi 6 Care of the Unit ooonconnccnnccnonccnocnnnonornrnnonnnnnenano 7 Caring for Your Ice Machine 8 Things to Remember oocccccnocccccnocccononcnonancnnnnnnnnnns 9 Preparing Your Ice Machine for Storage 10 Obtaining Service oooococinocccinoccconnocononancnnnnncnnnnos 11 Wait 12 Troubleshooting ccccoooooccncccnococcconccnnonanonoss 13 16 STARTING OUT Remove Packaging Your ice machine has been packed for shipment with all parts that could be damaged by movement securely fastened Before installing the ice machine be sure all packing materials and tape have been removed Important Save the carton packaging until your ice machine has been thoroughly inspected and found to be in good condition If there is damage the packaging will be needed as proof of damage sustained in transit Note to Customer This ice machine was carefully packed and thor oughly inspected before leaving our plant Responsibility for its safe delivery was assumed by the carrier upon acceptance of the shipment As directed on the side of the packaging carton
3. ing directly down on the tube 5 inches from the front of the tube to get a desired bin level Use a level to check the unit for level from side to side and front to rear Room temperature is too cold Move the unit to an area where temperature is above 55 F The selector switch is not in the ON position Water keeps backing up into the ice bin gravity drain Inadequate drain system Set the rocker switch on the grille of the ice machine to the ON position Restriction or improperly installed drain lines will cause water to back up into the ice bin Make certain there are no kinks or restrictions in the drain lines If necessary consult a qualified plumber Foreign material in ice bin drain Water keeps backing up into the ice bin drain pump Drain pump tubing kinked or restricted Foreign material is restricting or blocking the ice bin drain located at the right rear corner of the ice bin The drain will need to be cleared Check inlet discharge and vent line tubing for any kinks or restrictions and repair as necessary Inlet screen to the drain pump is restricted or blocked Clean the inlet screen to the drain pump Drain pump and or the ice machine are not level The drain pump cycles on and off erratically kinked Vent line to the drain pump is restricted or Check and level if necessary the drain pump as well as the ice machine Check the vent line for any
4. ES ACCESS PANEL 4 DRAIN PUMP figure 2 POWER CORD VENT TUBE GOES THRU gt OPENING IN THE ACCESS PANEL p mm ER 8 37 H 6 75 FRONT TOP i 14 75 A OF UNIT OF UNIT SS 2 38 18 00 1 4 06 o L 1 21 50 BASEPLATE OPENING FOR GRAVITY DRAIN Gravity Drain Location With optional filler kit Drain Plumbing Your ice machine uses a gravity drain figure 1 that requires 5 8 I D tubing from the back of the ice machine to a plumbed connection to a sanitary sewer Remove the access panel to plumb in drain connection Gravity drain location for built in units can be within the area shown in figure 3 An option al drain pump figure 2 can be purchased for your ice machine if a gravity drain is not accessible OBSERVE AND FOLLOW ALL LOCAL CODES WHEN INSTALLING ICE MACHINE WARNING FAILURE TO USE ADEQUATE DRAINAGE SYSTEM WILL RESULT IN SURROUNDING WATER DAMAGE AND OR POOR ICE PRODUCTION WATER SUPPLY Water Supply This ice machine must be connected to a potable active cold water supply line delivering water pressure at a minimum of 20 psi and maximum of 120 psi e Water connection is made through a right angle garden hose fitting supplied with ice machine See garden hose fitting for detailed instruction sheet Do not use any thread sealers e A water filter can be used with this unit A quality filter can help remove par
5. claims for loss or damage sustained in transit must be made on the carrier as follows Exterior Damage Make a thorough damage notation on the delivery receipt and have the driver acknowledge by signing and dating Send a written request to the carrier asking for an inspection report from the carrier representative and the date the inspection was requested Retain the inspection report and receipt for filing of a claim Concealed Damage This must be reported to the carrier within fifteen days Obtain an inspection report from the carrier Retain the inspection report for filing of the claim DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER FILE THE CLAIM WITH THE CARRIER Select Location The proper location will ensure peak perform ance of your ice machine Choose a location away from heat and out of direct sunlight Best performance will be maintained when installed within the following parameters Ideal Ambient Temperature Range built in 55 80 F freestanding 55 90 F Ice Machine will not perform correctly in ambient temperatures less than 55 F Cabinet Clearance Ventilation is required for the bottom front section of the unit where the grille is located Keep this area open and clear of any obstructions Adjacent cabinets and countertop can be built around the unit as long as no top trim or counter top is installed lower than the top of the hinge Make certain that the glides supplied with the ic
6. INSTALLATION AND USE INDIVIDUAL RESULTS MAY VARY Evaporator Distributor Make sure that distributor tubing is not in the path of the ice slab Escutcheon NG Evaporator Reservoir Front cover panel Front cover screws Grid cutter Ice deflector Ice scoop retainer Bin level sensor Ice scoop On Off Clean selector switch Distributor Circulation pump Reservoir drain plug PREPARING YOUR ICE MACHINE FOR STORAGE Storage of Ice Machine If the ice machine is to be moved not used for an extended time or will be in an area that will be near freezing temperatures below 37 F it is 5 Unplug the unit from the electrical outlet 6 Remove back panel from the rear of the unit 7 Disconnect the water valve s outlet water line necessary to remove the remaining water in the to the reservoir and drain the remaining water ice making system left in the water line trap area CAUTION ALL WATER MUST BE DRAINED AND REMOVED TO PREVENT ICE MACHINE DAMAGE AND POSSIBLE WATER DAMAGE TO 8 Reconnect water valve outlet water line and tighten compression n
7. One Year Limited Warranty AGA Ranges will supply replacement parts for the hemetically sealed refrigeration system which consists of the compressor condenser drier accumulator by pass valve connecting tubing and the evaporator that are proven to be defective due to worksmanship or materials subject to the conditions and exclusions below The above warranties do not cover Shipping costs of replacement parts or returned defective parts Customer education or instructions on how to use the appliance e Any content loss due to product failure e Removal or installation Nor do the above warranties cover failure of this product or its components due to Transportation or subsequent damages e Use commercially or use other than normal household or small office e Improper installation misuse abuse accident or alteration use on wiring not conforming to electrical codes low or high voltages failure to provide necessary maintenance or other unrea sonable use Parts or service not supplied or designated by Aga Ranges The warranties denoted previously do not apply if e The original Bill of Sale deliver date or serial number can not be verified e Defective parts are not returned for inspection if so requested by Aga Ranges e The refrigeration equipment is not in the possession of the original end use purchaser The warranties set forth herein are the only warranties extended by Aga Ranges Any imp
8. for service calls Proper installation including installation of level ing legs Leveling of unit Alterations to original equipment Removal or installation of additional equipment i e drain pump Cleaning and normal maintenance outlined in this manual Drain and water supply plumbing to the ice machine Help Prevent Tragedies Each year children die because they climb inside a discarded refrigeration product get trapped inside and suffocate Take precautions to prevent such tragedies by removing the door taping or chaining it shut before discarding CARING FOR YOUR ICE MACHINE Cleaning Your Ice Machine Some impurities will remain and build up in the ice machine and stick to the ice machine s parts over time This build up must be removed for proper ice production ice quality and ice machine life Your ice machine is equipped with a cleaning mode that will help in cleaning out these impurities The impurities will need to be cleaned of this build up regularly at the very least annually depend ing on use and water hardness You can use an acid such as one specified for ice machine clean ing or you can use citric acid to remove the build up To clean the ice machine 1 Switch the selector switch to the OFF position 2 Remove the drain plug at the bottom of the reservoir to drain any remaining water and then reinstall 3 Add the recommend cleaner solution to the reservoir of the ice mach
9. lamp to make certain outlet has power Make sure ice machine s switch is in the ON position Make sure that there is cold water supplied to the ice machine e Make sure drain plug on bottom of reservoir is inserted Make certain unit is level from front to back and side to side Make certain that the drain line to the ice machine is not restricted or kinked e Use troubleshooting guide pages 13 16 for other diagnosis If you are not able to correct the problem contact your dealer or the manufacturer Be sure to have the model number and the serial number handy before you call The model and the serial number are located on the lower front part of the ice machine s cabinet How to Obtain Service Your ice machine requires little service because the best and most up to date materials equip ment and quality control methods are employed throughout the manufacturing process If trouble occurs during normal operation read Things to remember section first and if neces sary check the troubleshooting guide If service becomes necessary 1 If the product is within the first year warranty period please call Marvel Customer Service at 800 428 6644 for directions on how to obtain warranty coverage in your area 2 If the product is outside of the first year warranty period Marvel Customer Service can provide recommendations of service centers in your area A listing of authorized service centers is also a
10. restrictions or kinks and repair as necessary Discharge line is restricted or kinked The drain pump is not level Check the discharge line and connection to the desired drain for any restrictions or kinks and repair as necessary The drain pump must be level Check for level on the top of the drain pump case and adjust the tubing or use shims to level 16 NOTES NOTES Aga Ranges Refrigeration Products Divisim P On Box 997 Richmond Indiana 47375 USA 1 800 243 1624 41010396 Rev A
11. the distributor and then reinstall the distributor tube to the evaporator with the spray holes pointed to the bottom of the evaporator plate Reinstall the front cover panel with the two front panel screws 10 11 Clean the ice machine s interior ice scoop interior door panel and door gasket with mild soap and water Using two tablespoons of baking soda in one quart of warm water while cleaning will help remove odors Rinse with fresh water Do not use any abrasive cleaning products Your ice machine is now clean and sanitized and may be put back into operation by switching the selector switch to the ON position THINGS TO REMEMBER Things to Remember Allow your ice machine to run for 24 48 hours to accumulate ice in ice machine s bin Unit will cycle often between ice production and ice harvest cycles Your unit will automatically shut down when the ice bin is full Unplug your ice machine before working on unit Keep your ice machine clean for proper ice quality production and unit life Room and water temperatures will greatly affect the output of ice in your unit see table Ice will also melt away especially at the start of an empty bin but will slow down as ice accumulates ROOM TEMPERATURE F PRODUCTION RATE LB DAY WATER TEMPERATURE F ROOM TEMPERATURE F APPROXIMATE TIME TO FILL BIN HOURS WATER TEMPERATURE F NOTE DUE TO VARIABLES IN
12. PS ARE SECURE i o dg COMPRESSION FITTING squares by the grid cutter s heated wires During the harvest cycle the drain valve will remain open for 45 seconds to drain the reservoir of remaining deposits After that the water valve open will open for 2 minutes providing 2 quarts of water to the reservoir for the next ice production cycle The ice machine will keep producing ice until the ice machine s bin is full and will restart automati cally when ice needs to be replenished in the bin CARE OF THE UNIT Care of Unit 1 Avoid leaning on the cabinet door You may bend the door hinge or tip the unit Exercise caution when sweeping vacuuming or mopping near the front of the unit Damage to the grille and or switch can occur Periodically clean the inside of the ice machine components and inside of unit see Cleaning Your Ice Machine section Periodically check and or clean the front grille and condenser coils as needed If your ice machine has either a stainless steel door and or cabinet to keep it looking its best we recommend periodically applying a stain less steel cleaner and a non abrasive stainless steel polish This is especially important for outdoor applications and locations near salt water environments Normal Responsibilities of the Owner All freight charges Damage sustained in transit Mileage charge s
13. ROBLEM POSSIBLE CAUSE Unit does not operate The unit is unplugged 0333011015 Plug in the unit Breaker is tripped or fuse is blown Reset breaker or replace fuse Check to make sure there is not a short in the electrical circuit Ice machine selector switch is in the OFF position Unit operates but does not produce The unit has just been started and it has any ice been less than 6 hours Set the rocker switch on the grille of the ice machine to the ON position Ice produced when the unit is initially started will melt off in the bin Ice will accumulate in the bin In 6 hours there can be a few cubes in the bin This is normal operation Typical ice production cycle can take up to 1 5 hours Initial startup cycles can be longer Check the unit in 24 hours for ice accumulation in the bin The selector switch is in the OFF or CLEAN position Set the rocker switch on the grille of the ice machine to the ON position No water in the reservoir Make sure that the reservoir drain plug is installed Check the water line to the unit to make sure it is on and that there are no restrictions or kinks in the line Check all filters to make sure they are not restricted or plugged Distributor tube is restricted See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation Build up of deposits on evaporator plate See CLEANING YOUR ICE MACHINE section for cle
14. an ing the unit for proper operation Condenser fan air flow is restricted Make certain the grille in the front of the unit is free and open for proper air circulation Check and clean the con denser coil by removing the grille in the front of the unit Room and or water temperature is too warm Clean the condenser with a vacuum and brush attachment Move the unit to an area where ambient temperature is below 90 F The unit should not be placed next to a heat source such as an oven Check for cold water connection Leaking drain valve See CLEANING YOUR ICE MACHINE section for clean ing the unit This will also dissolve and flush out foreign material in the drain valve causing it to leak Inadequate drain system Restriction in drain lines will cause ice in the bin to melt If using a gravity drain make certain there are no kinks or restrictions in the drain lines If using a drain pump check the inlet screen discharge line and vent line for any build or restrictions Grid cutter is unplugged Plug in the grid cutter so that ice slabs can be cut into cube Circulation pump is unplugged Plug in the circulation pump so that water from the reservoir can be circulated over the evaporation plate TROUBLESHOOTING TWO PROBLEM Ice cubes are too small less than 1 2 inch thick Ice cubes are too big greater than 3 4 inch thick Hollow ice slab POSSIBLE CAUSE Low ice consu
15. e machine are installed according to instructions Make certain your ice machine is level Leveling adjustments can be made by raising or lowering the glides on the bottom of the unit Grounding Method This ice machine is equipped with a power supply cord with ground It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances I D O TI THIS UNIT SHOULD NOT UNDER ANY CIRCUMSTANCES BE UNGROUNDED INSTALLATION 24 19 a ka 23 63 ra A475 r i lt eu 21 50 al a a mn h 23 82 25 63 34 00 LI A _ SUPPLIED WATER y LINE FITTING 1 0 56 Lk 23 88 WARNING DISCONNECT POWER SOURCE BEFORE ADJUSTING LEVELING LEGS Electrical Connection Check the serial nameplate for the correct power supply Use only the electrical power supply specified on the serial nameplate on the back of the door Do not use an extension cord INSTALLATION DRAIN PLUMBING N 5 8 INCH I D fl DRAIN TUBING AND HOSE CLAMP 1 1 2 DRAIN PIPE ACCESS PANEL figure 1 DRAIN FROM F N ICE MAKER ICE MAKER POWER CORD TUBING CLAMPS ___ VENT TUBE SUPPLIED SCREWS N DISCHARGE TUBE GOES THRU THIS OPENING IN THE ACCESS PANEL 3 WE 4
16. e and open the drain valve to drain the reservoir and the ice machine drain system reconnect leave it shut off DO NOT turn the water on and allow water to enter the valve Draining Water for Optimal Drain Pump Life 1 Remove the drain pump from the ice machine refer to drain pump installation instructions 2 Drain the water in the drain pump s reservoir by turning the pump upside down and allow ing water to drain through the pump s inlet and vent tube fittings 3 After all water is drained reinstall the drain pump Make certain all tubing is installed and all hose clamps are tight refer to drain pump installation instructions Restarting the Ice Machine 1 With the rocker switch in the OFF position plug the unit into an electrical outlet 2 Reconnect or turn on the water supply line 3 Reconnect the drain tubing if removed 4 Turn the rocker switch to the ON position 5 Check the water inlet drain lines and fittings for any water leaks 6 Check drain pump if equipped operation by pouring approximately 2 quarts of water into the ice storage bin The drain pump should activate and discharge water refer to drain pump installation instructions Check for water leaks at all hose connections 11 OBTAINING SERVICE Before Calling for Service Before calling for service check the following items e Make sure unit is plugged into outlet e Check the outlet for power Test outlet with
17. ine Access to the reservoir can be obtained by removing the front panel screws and the front panel Determine the proper amount of cleaner from the ice machine cleaner manufacturer s mixture ratio based on 3 quarts of water refer to manufacturer s directions 4 Replace the front cover panel and close the door 5 Switch the selector switch on the grille of the ice machine to the clean position Three quarts of water will automatically be added to the cleaning solution WARNING Read manufacturer s warnings on ice machine cleaner products Personal injury can result 6 The total cleaning time will end in 49 min utes The cleaning cycle will automatically rinse the evaporator plate and also drain the cleaning solution and rinse water 7 After the cleaning cycle has ended remove the front panel again and check that the build up has been removed The evaporator plate should be clean shiny and smooth to the touch If build up is still visible repeat the cleaning cycle above If build up is removed continue below 8 Remove the distributor tube hose clamp hose and its rubber ends 9 Thoroughly clean the inside of the distribu tor tube and the spray holes You can use the same cleaning solution as before and an old toothbrush to reach the inside of the dis Spray Holes Rubber Ends tributor tube a o 6 6 6 J Reinstall the rubber ends hose and hose clamp to
18. lied warranties including the implied warranty of merchantablility are limited to the duration of these express warranties In no event shall Aga Ranges be liable for any consequential or incidental damages or expenses resulting from breach of these or any other warranties whether expressed or implied Some states do not allow the exclusion or limitation of consequential damages or limitations on how long an implied warranty lasts so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state No person firm or corporation is authorized to make any other warranty or assume any other obligation for Aga Ranges These warranties apply only to products used in any of the fifty states of the United States and the District of Columbia To obtain performance of this warranty report any defects to Aga Ranges Refrigeration Products Division Warranty Administration P O Box 997 Richmond Indiana 47375 USA 1 800 243 1624 In no event shall the company be liable for incidental or consequential damages including but not limited to content loss Some states do not allow limitations on length of time implied warranty may last so the above limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state 13 TROUBLESHOOTING ONE P
19. mption CORRECTION Ice is slowly melting in the ice bin and will affect the size of the ice cube This is normal operation When the ce bin needs to be replenished cubes will return to regular size Not enough water in reservoir Make sure that the reservoir drain plug is installed properly Check the water line to the unit to make sure there are no restrictions or kinks in the line Check all filters to make sure they are not restricted or plugged Distributor tube is restricted See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation Build up of deposits on evaporator plate See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation and cube size Inadequate drain system Restriction in drain lines will cause ice in the bin to melt to a thinner cube If using a gravity drain make certain there are no kinks or restrictions in the drain lines If using a drain pump check the inlet screen discharge line and vent line for any build up or restrictions Leaking drain valve See CLEANING YOUR ICE MACHINE section for clean ing the unit This will also dissolve and flush out foreign material in the drain valve causing it to leak Room temperature is too warm Ice slab not releasing Move to an area where temperature is below 90 F See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation and cube size Co
20. ndenser fan air flow is restricted Make certain the grille in the front of the unit is free and open for proper air circulation Check and clean the con denser coil by removing the grille in the front of the unit Clean the condenser with a vacuum and brush attachment Room temperature is too warm Distributor tube is restricted Move to an area where temperature is below 90 F See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation Build up of deposits on evaporator plate See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation and cube size Low water level in reservoir Make sure that the reservoir drain plug is installed properly Check the water line to the unit to make sure there are no restrictions or kinks in the line Check all filters to make sure they are not restricted or plugged 14 15 TROUBLESHOOTING THREE PROBLEM Ice is not clear Low ice production Unit is running has run over a 48 hour period and there is little ice in bin Unit continues to run and produce ice Grid cutter is not cutting the ice slab POSSIBLE CAUSE Low water level in reservoir CORRECTION Make sure that the reservoir drain plug is installed properly Check the water line to the unit to make sure there are no restrictions or kinks in the line Check all filters to make sure they are not restricted or plugged Softened water sup
21. ply Make certain that water line is not connected to the water softener Room temperature is too cold Low water level in reservoir Move the unit to an area where room temperature is above 55 F Make sure that the reservoir drain plug is installed properly Distributor tube is restricted Check the water line to the unit to make sure there are no restrictions or kinks in the line Check all filters to make sure they are not restricted or plugged Build up of deposits on evaporator plate See CLEANING YOUR ICE MACHINE section for clean ing the unit for proper operation Inadequate drain system Restriction in drain lines will cause ice in the bin to melt If using a gravity drain make certain there are no kinks or restrictions in the drain lines If using a drain pump check the inlet screen discharge line and vent line for any build up or restrictions Condenser fan air flow is restricted Ice bin is not full Make certain the grille in the front of the unit is free and open for proper air circulation Check and clean the con denser coil by removing the grille in the front of the unit Clean the condenser with a vacuum and brush attachment The unit will automatically shut down when ice reaches the sensing tube Ice bin is full The unit will automatically shut down when ice reaches the sensing tube and has completed the harvest of the ice slab Room temperature is too warm
22. ticles as well as remove taste and odors from water Do not use a reverse osmosis filtering device Softened water is not recommended This will produce soft cloudy ice cubes that will stick together De ionized water is not recommended This water will not form solid ice cubes A water specialist can recommend proper water treatment After installation of water line turn on water and check for any leaks Additional tightening may be needed Allow for extra water line for built in installations for easy removal of unit and to help prevent the water line from kinking Operation Your ice machine is unique in forming ice It uses fractional freezing to form a slab of ice that is clear and has less mineral content than the water it is produced from This is accomplished by running water over the cold evaporator plate which gradu ally freezes the water to produce the ice slab Mineral deposits are left in the reservoir When the ice slab reaches the correct thickness determined by the temperature of the evaporator plate the electronic control switches to the har vest cycle to harvest the ice During the harvest cycle the ice slab falls from the evaporator to the ice grid cutter Here the ice slab is cut into 3 4 LO 1 4 INCH REAR OF UNIT lo TUBING FROM COLD WATER LINE GARDEN HOSE 5 8 I D DRAIN lo o FITTING TUBING BARB MAKE CERTAIN ALL HOSE CLAM
23. ut to a watertight seal 9 Reinstall the unit s back panel THE SURROUNDING AREA IN FREEZING CONDITIONS THESE DAMAGES ARE NOT COVERED UNDER WARRANTY 10 Clean and dry the ice storage bin 11 Prop the door open for air circulation and to prevent mold and mildew WARNING Leave water supply line disconnected or if DO NOT USE ANTI FREEZE OR OTHER SOLUTIONS AS A SUBSTITUTION FOR PROPERLY DRAINING THE ICE MACHINE 12 Cleaning of Ice Machine for Storage Cleaning the ice machine will prevent mold and mildew growth as well as sanitize the unit for stor age or when it is put back into service 1 Remove all ice from the ice storage bin 2 Pull the reservoir drain plug to drain reservoir 3 Reinstall the drain plug after all of the water has drained 4 Add ice machine cleaning solution to ice machine s reservoir Refer to the machine care section of guide for further information 5 Switch the rocker switch in the grille to CLEAN position 6 The clean cycle will complete in 50 minutes Draining and Removing Water from System 1 Turn off the water supply to the ice machine 2 Disconnect the water supply fitting at the inlet of the water valve 3 Switch rocker switch to CLEAN for about 1 minute This will energize and open the water valve and remove most of the water from the valve and the outlet water line to the reservoir 4 Switch rocker switch to OFF position This will energiz
24. vailable at www marvelindustries com under the service and support option 3 In all correspondence regarding service be sure to give the model number serial num ber and proof of purchase 4 Try to have information or description of the nature of the problem how long the unit has been running the room temperature water temperatures and any additional informa tion that may be helpful in quickly solving the problem IMPORTANT SEND IN YOUR WARRANTY RECORD CARD IMMEDIATELY AFTER TAKING DELIVERY OF YOUR ICE MACHINE Every new ice machine that leaves the factory contains this Owner s Guide Keep this Owner s Guide in a safe place for convenient reference For Your Records Date of Purchase Dealer s Name Dealer s Address Dealer s city Dealer s State Appliance Serial Number Model Number Date Warranty Card Mailed within 10 days of purchase WARRANTY Household Refrigeration Products Limited Warranty Entire Product Limited One Year Parts and Labor Warranty Aga Ranges warrants that it will supply all necessary parts and labor to repair or replace in the end user s home or office any component which proves to be defective in materials or worksmanship subject to the condition and exclusions stated below for a period of one year from date of purchase by the user Additional Second Through Fifth Year Limited Parts Only Warranty During the four years following expiration of the

Download Pdf Manuals

image

Related Search

Related Contents

Peavey Q 131 User's Manual  GABARITO OFICIAL APÓS ANÁLISE DE RECURSOS 01 D 02 C 03  XX.Y Dynamic 21 User's Manual  Cisco Catalyst 2960-X  1 - Fujifilm  PFP13077 2630 Documentation.book  

Copyright © All rights reserved.