Home
A&D UC-324NFC User's Manual
Contents
1. A amp D Medical Precision Health Scale UC 324NFC Instruction Manual 1WMPD4002355B Contents Before Use PIOCAUNONS an pam LANA REA Scale COMPOMEINS bana ama Ren A A nb nia KAA Display SY MBOIS unseres AA A RAN BEN RA AT SAN EA Ta EN Automatic Power Off Function Jeena il Near Field Communication NFC Function ooo ak Installing or Replacing the Batteries nn Measuring Your Weight on a Carpet o ooooooo Wo Woo Operations Setting Their een ee Measuring Your Weight Using the NFC Function emma References Maintaining the Scale SER es a Before Requesting SEN esensi batin BNN Ra Caution on Using the NFC Function ur nalen Specifications ae Ra an an Precautions m Please read this booklet before using your scale m Place your scale on a solid level surface such as tile wood or laminate flooring m Do not place your scale on a soft wet or slippery floor If the scale must be used on a carpet be sure to attach the plastic add on feet as shown on Page 4 m Your scale contains delicate high precision parts Avoid extremes in temperature humidity direct sunlight shock moisture and dust m Do not step on your scale with your feet wet Be sure that your feet are dry to prevent slipping or serious injury Step on the center portion of your scale gently A caregiver should attend when a disabled person uses the scale Consult with yo
2. ations for the communication devices refer to the instruction manuals for the devices Installing or Replacing the Batteries Caution m Insert each battery with its positive and negative terminals properly aligned with the corresponding symbols in the battery compartment m Improper installation of the batteries may cause battery leakage m Replace all four batteries with new ones when the T di symbol is displayed m Do not mix new and used batteries It may cause damage to the scale or shorten the battery life m The L 4 symbol does not appear when the batteries are completely drained m The battery life is dependant upon the environmental temperature battery type and usage m Remove the batteries from the battery compartment when the scale is not to be used for a long time They may leak and damage the scale m The batteries provided with the scale are for trial only and may have a short life Steps for Installing or Replacing Batteries 1 Open the battery compartment cover on the underside of the scale 2 Install four new batteries with the positive and negative terminals properly aligned with the corresponding symbols in the battery compartment 3 Close the battery compartment cover Measuring Your Weight on a Carpet Place the scale on a solid level surface such as tile wood or laminate flooring Ifthe scale must be used on a carpet be sure to attach the plastic add on feet Steps for Attachin
3. ed 6 u Dam Kai YU 4 m u Da Maintaining the Scale m Clean the scale with a soft dry cloth or a cloth moistened with water and a mild detergent Never use alcohol benzene thinner or other harsh chemicals to clean the scale m Remove the batteries from the battery compartment when the scale is not going to be used for a long time Before Requesting Service Problems Possible Reason Corrective Action is displayed m Exceeds the maximum capacity El is displayed SR Exceeds the maximum capacity Err is displayed Was Does not reach the minimum capacity r i is displayed Bu TER The communication device may be slanted or placed E 11 is displayed Se Fa er out ofthe communication area of the scale E if is displayed H is displayed en Exceeds the maximum capacity H is displayed 1 A is displayed Nothing is displayed by tapping on the scale or pressing the SET switch Remove and reinstall the batteries Or replace all four batteries with new ones The measurement results are too much different from the expected values Place the scale on a solid level surface Remove any foreign objects that might be touching the bottom of the scale When the scale is placed on a carpet be sure that the add on feet are attached or try moving the scale to a level surface such as tile or wood If you can not
4. g the Add on Feet D 1 Each add on foot has two pins Add on foot i B Sad Scale leg F Match those pins to the holes on the scale leg and insert firmly 2 Attach add on feet on all four legs Notes m Please be careful not to fall when using the add on feet m We recommend using this scale on a solid and level surface 4 Setting the Unit Setting the unit manually 1 Confirm that the scale is turned off Press the SET switch The scale beeps and displays the unit currently set Press the SET switch kg SET switch 1 Press the SET switch to select the unit pan kg After three seconds of non operation the scale confirms the selected unit with two beeps displays End and automatically turns off Gaman m uw gt p Setting the unit by the communication device Only for devices that rewriting of the unit information is enabled 1 Confirm that the scale is turned off Hold the communication symbol of the NFC enabled device close to the communication area 4 of the scale 2 When the data transmission is complete the scale displays End and automatically turns off Note m The NFC enabled device may not be recognized when it is slanted or placed out of the communication area If or E appears start from step 1 again se a N Example Cellular phone O Measuring Y
5. locate and fix the problem contact your supplier or the A amp D service group The A amp D service group will support authorized suppliers with technical information spare parts and units Caution on Using the NFC Function The scale has an NFC Forum Type 3 Tag wireless interface module built in When the scale is used near wireless communication devices which use the same freguency as that of the scale 13 56 MHz or use its harmonic freguencies electromagnetic interference may occur In that case turn off the devices that are not in use or place the devices 1 meter or more away from the scale Specifications Type Maximum capacity Minimum capacity Minimum display Wireless communication Setting items Power source Battery life Dimensions Mass Accessories UC 324NFC 150 kg 330 Ib 10 kg 22 Ib 0 to 100 kg 0 05 kg 0 to 330 Ib 0 1 Ib NFC wireless interface module Unit kg or Ib Four type AA batteries R6P or LR6 1 5 volt x 4 Approximately 1 years with two measurements a day using Alkaline batteries 350 D X 350 W X 39 H mm 2 3 kg including the batteries Instruction manual Batteries 4 Add on feet 4 100 to 150 kg 0 1 kg Specifications are subject to change without prior notice or any obligation on the part of the manufacturer Compliance with European Directives C The scale complies with the statutory EMC Electromagnetic Compatibility directive 2004 108 EC Note Indoor use onl
6. our Weight Using the NFC Function After measurement the communication device receives the data 1 Confirm that the scale is turned off Turn off Step on the scale gently and stand still during the measurement The scale turns on displays all of the display segmenis 2 Wait the finish of the measurement The process of the measurement is displayed with segment tep on the scale 0000 0 BB O08 au x In processing of measurement 3 Step off the scale when the stable symbol o is displayed with three beeps Sound pi pi pi The stable symb If you do not step off the scale o Co Pa CC the scale beeps every two er 3 DE seconds Sound pi and the scale Step off the scale turns off after two minutes 4 The scale displays all of the display segments Ona Do not step on the scale SOLIS 5 Th is di The measurement result is displayed o Tai T PUPE 6 Point the communication symbol of the NFC enabled device to the communication area G4 on the scale 7 When the personal data transmission is complete the scale displays End Notes m The NFC enabled device may not be recognized neh it is iP or slanted or placed out of the communication area If E 12 appears start from step 5 again m After the measurement result is displayed about three minutes the scale will automatically turn off and the result will be delet
7. ur physician before you start a diet or exercises Do not disassemble or modify the scale Indications for Use m This scale is designed for personal use 4 Scale Components SE Switch Communication Area Battery Compartment Display Ready Stable Symbol 20000 0x Fo Sannt Accessories Instruction manual Batteries Display Symbols Symbols Name Description This symbol is displayed when the O bs Mus measurement display is stable MA Battery indicator The normal battery power indicator with charge remaining 4 Low battery indicator If this symbol is displayed replace all four batteries with new ones amp WEEE label CE CE mark Automatic Power Off Function The scale has an Automatic power off function m If 0 00 kg 0 0 Ib and the Ready Stable symbol are displayed for about forty five seconds the scale will automatically turn off m Ifthe O symbol and the weight are displayed for about three minutes the scale will automatically turn off Near Field Communication NFC Function To transmit data to or from the scale communication devices that comply with the communication specifications of the scale are required Examples of communication devices that comply m NFC enabled cellular phone m Personal computer with NFC reader writer m Access Point Notes m For information on communication methods and applic
8. y The displayed value may be adversely affected under extreme electromagnetic influences A amp D Company Limited 1 243 Asahi Kitamoto shi Saitama 364 8585 JAPAN Telephone 81 48 593 1111 Fax 81 48 593 1119 A amp D INSTRUMENTS LTD Unit 24 26 Blacklands Way Abingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A amp D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A8D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A amp D KOREA Limited 5201 0 C F ana ASA SET FINES 36 2 Woe B D 8F 8th Floor Manhattan Bldg 36 2 Yoido dong Youngdeungpo ku Seoul KOREA 13 82 2 780 4101 MA 82 2 782 4280
Download Pdf Manuals
Related Search
Related Contents
Copyright © All rights reserved.
Failed to retrieve file