1. Page Power kVA Technology acc to IEC 62040 3 Input Output Parallel operation Autonomy time min at full load fe Warranty 1 to 10 kVA Tower UPS for sensitive networks small computer centres Intranet and Internet servers 26 1 10 KVA VFI double conversion 1 ph 1 phx yes 6 amp 10 kVA 5 60 1 to 6 kVA UPS for rack usage to protect sensitive networks small computer centres Intranet and Internet servers 28 1 6kVA VFI double conversion 1 phs 1 phx no 5 60 Our high standards and decades of experience mean we are also able to offer services which are cost effective efficient and quick For the first 24 months after the initial purchase we provide a comprehensive advanced replacement service for the device and battery from the compact UPS series 36 months Bi ae A ad 36 months warranty on UPS and battery Register your UPS within two months from date of purchase and you will get the warranty extension Pro Care Garant for free So we provide an overall warranty for 36 months on UPS and battery The registration form is available at www aegpartnernet com Also available with enhanced battery charger for autonomy times over a period of hours Fesih Protect D 1 to 10 kVA Compact UPS for rack usage protects server networks and IT equipment 30 1 3 KVA 6 amp 10 KVA in preparation VFI double conversion 1 phs 1 phx no 3 60 Service and warra
2. 220 Vac 230 Vac 240 Vac 5 50 Hz 60 Hz 0 1 Hz 3 2A 4 3A 6 5 A 8 7 A 13 0 A 2 4 ms typical 6 ms max sinusoidal 110 for 3 Min 150 for 200 ms yes yes yes yes yes sealed maintenance free hot swappable from 1500 VA 24 Vde 48 Vdc 96 Vde 5 min 5 min 5 min 5 min 5 min Runtime extension with scalable ext battery packs yes yes yes yes yes 3h 3h 3 3h Shh USB and RS232 for status and measurement levels Slot for enhanced communications pot free contacts SNMP EPO port for emergency power off Configuration panel for voltage preselection and setting of operating mode Included for all typical operating systems e g Windows Linux Mac single licence CompuWatch with a 5 fold network licence Separate LED bar graphs for UPS load and battery capacity indicators for mains failure overload battery discharge battery replace failure lt 45 dB A 0 35 C EN 50091 2 Class A EN 61000 3 2 EN 61000 3 3 EN 62040 1 1 RJ11 Phone Fax Modem RJ45 Ethernet 10 Mbit s 100 Mbit s 0 90 non condensing up to 1000 m at nominal load 6 x IEC 320 13 removable module APEC 320 1Gi3 8 x IEG 320 G13 1 x IEC 320 C19 Blackline 217 x 88 x 414 217 x 88 x 414 8 5 kg 9 5 kg 6 5 kg 12 kg Mains cord 2 load cords IEC 320 10A USB and RS232 communication cable management software CompuWatch CD user manual CE 235 x 88 x 383 438 x 88 x 582 438 x 88 x 582 31 5 kg 40 5 kg Protect B PRO Protect B
3. AVR control rage inverter transfer e load is fed by unfiltered voltage no correction by the inverter Disadvantages e ower efficiency in comparison to VI technology e more cost intensive comparison to VFD technology Protect Home Protect Home Uninterrupted Protection for PCs USB and RS232 Connections for Simple Control Practical Protection Especially for multi media applications the Protect Home offers data line protection for telephones faxes and modems as well as surge protection for satellite TV Connections are made directly to the UPS outlets Protect Home proves itself in critical situations with its high availability due to a sturdy overload and excess voltage protection The Protect Home is quickly connected to a USB or RS232 interface Through the special AEG shutdown software CompuWatch which is included the unit allows you to control the most important operations as well as provides for automatic shutdown during longer power outages Thanks to its user friendly battery design Protect Home emphasizes its remarkable economy Simple Operation The One Board Design as well as LED notification provides clear information about the unit s most important operating conditions With the addition of an audible alarm the user is provided with clear notification of critical events Input circuit breaker Mains connection Overload protection SAT TV SAT receiver Overload protec
4. PROTECT Uninterruptible Power Supplies and Surge Protection for Data amp IT applications gh r nee ne p ao A oF i AEG Input Output fale VUI Smin 230 T AUHz nae SUyz E 11076 4 yt 3 A ENTER SE Date 2011 PERFECT IN FORM AND FUNCTION AEG UPS The right UPS for every application AEG Power Solutions provides customized solutions for protection against network disruptions and the loss of data and costly downtime periods suffered as a result Plug amp Safe options Our range of compact UPS systems includes UPS devices for private use systems which can be incorporated into racks for the IT cabinet and Plug amp Safe parallel switchable modular UPS systems for computer centers and industry Product support As a renowned and experienced company AEG Power Solutions is there to support you by providing easily expandable products reliable delivery and offering trade oriented support and service packages Our group and global experience AEG Power Solutions is a world leading provider of premium power electronics Since September 2009 the group is a listed company through its holding company 3W Power holding SA It offers one of the world s most comprehensive product and service portfolios in power conversion and control for customers spanning the infrastructure markets of energy telecom lighting transportation general industrial as well as new energies
5. Fvtension A 0clEC320 C13 6599 acminunieatian Microprocessor control DSP guarantees highest slot UPS outputs interface availability e Sine wave shaped current consumption High frequency PWM with IGBTs e Automatic bypass additional integrated service bypass at 6 and 10 kVA tower e Redundancy due to n x configuration at 6 and 10 kVA increase in power output safety and availability e Expansion slot for extension cards SNMP relay card USB potential free contacts eh oe for External battery e Free 36 months warranty on UPS and battery with eon COMEEKOF advanced replacement service registration required Protect C 2000R amp C 2030R BP e Rear view Protect C Rack Autonomy times Protect C Rack autonomy time full halfload in min 1000 VA 2000 VA 3000 VA 6000 VA Standard autonomy time 6 20 1 additional BatteryPack 38 97 10 30 5 16 8 26 2 additional BatteryPacks 76 170 30 85 17 49 26 67 3 additional BatteryPacks 55 130 30 85 47 112 4 additional BatteryPacks 83 180 48 114 67 157 5 additional BatteryPacks 106 237 60 149 94 203 Classification VFI SS 211 acc to IEC 62040 3 Classification VFI SS 111 acc to IEC 62040 3 Type rating Part number Rack Part number BatteryPack Part number Rack S Version UPS INPUT Input voltage Input voltage range without battery mode Frequency Power factor Current consumption max UPS OUTPUT Rated output voltage Frequency in battery mode O
6. PRO Efficient protection with innovative LED operation display Load Operating mode Protect B PRO Display amp control terminal RS232 amp USB communication interfaces Expansion slot EPO Protect B 1000 PRO Rear view easy battery exchange by foldable front design Status display UPS figures Battery status Control buttons Network connection High level flexibility intelligent functions e Modern VI line interactive protection 8 x IEC320 C13 outlets 4 of them controllable technology with sine wave output voltage e Lower operating costs by higher efficiency 0 9lag power factor e compact construction and variable use due to combination design tower rack display rotateable e robust design overload capability and short circuit protection e overvoltage protection RJ11 RJ45 for phone fax modem and network e configuration directly via multi language display e comprehensive display with most important UPS values e intelligent monitoring with USB and RS232 interfaces parallel mode with expansion slot possible e Free 36 months warranty on UPS and battery with advanced replacement service registration required Mains input rotatable display device stands Protect B PRO features for server and networks Classification VI SS 211 acc to IEC 62040 3 Type power Part number UPS INPUT Input voltage Input vo
7. the Shutdown function Following a specified delay after power has been restored the network will also be automatically restarted and systems will be initialised the Reboot function UPS Coniguretian Test Control Punc tons Hamburg Frankfurt AG inistrator Network management for UPS devices a Solution for intelligent network management The network management software for UPS devices allows an easy control of many UPS devices even in disturbed networks It gives the administrator an overview about all installed UPS devices and shows the actual status of the several locations This increases the security and availability and allows a centralized administration The software sends an alert e g by email whenever a problem occurs The network management software is supported by every common web browser and gives the necessary flexibility in administrating larger networks UPS status information log history and reports can be viewed everywhere via web browser Special features e Web based remote monitoring of power supply systems in the network e Simple operation of a complex power supply management system e Alerting of events via network messages emails Short Message Services SMS e Storage of all events in a logbook e Graphics for statistical analysis e Customized presentations with background graphics are possible A free basic version of the software is available for up t
8. 130 164 6 pulse 12 pulse 116 80 1710 1815 1200 735 800 3 33 100 100 163 205 6 pulse 12 pulse 145 100 1710 1815 1200 135 900 3 33 120 120 195 246 6 pulse 12 pulse 173 120 1710 1815 1200 900 Protect 4 33 Protect 4 33 Online UPS system for large datacen Key features a P i e Highest operating safety amr e Optimum efficiency even in the partial load range e Fully loadable neutral conductor e Short circuit proof e Overload capacity available e Standardised components e Intelligent battery charging management e Integrated logbook function with real time clock e Terminal emulation VT100 via RS232 e Security thanks to internal redundancy separate micro processor for control of rectifiers inverters and electronic bypass e Ergonomic full grafical display for ease of operation clear letter indication 17 diff languages e Integrated network interface incl SNMP agent for network management optional e Reliable shutdown and reboot using AEG PSS network software Compuivateh via R5232 C bridae Classification VFI SS 111 according IEC EN62040 3 e Manufactured to DIN ISO 9001 The PROTECT 4 is a compact ready to install unit with a maximum single unit capacity e CE compliant of 1000 kVA available now for the first time and opening up completely new dimensions e Low maintenance requirement in protection Whether used to protect comp
9. 16 kVA no n 1 n 2 redundancy 4 kVA 8 kVA 20 kVA no n 1 redundancy 4 kVA 24 kVA no redundancy ALLOCATION OF THE BATTERY CABINETS AVAILABLE EX STOCK IN PROTECT 1 M CONFIGURATION 15 min 20 min 4 kVA 8 kVA 1 x 1 M BP28 12 kVA 1x 1 M BP42 1 x 1 M BP65 16 kVA 1x 1 M BP56 20 kVA 1 x 1 M BP84 24 kVA 1x 1 M BP84 2 x 1 M BP65 Other designs are available on request 30 min 1 x 1 M BP42 1 x 1 M BP84 1 x 1 M BP84 1 x 1 M BP42 1 x 1 M BP84 1 x 1 M BP42 40 min 1 x 1 M BP28 1 x 1 M BP56 1 x 1 M BP84 1 x 1 M BP84 1 x 1 M BP42 3 x 1 M BP65 2 x 1 M BP84 60 min 1 x 1 M BP42 1 x 1 M BP84 2 x 1 M BP65 2 x 1 M BP84 2 x 1 M BP84 1 x 1 M BP42 4x 1 M BP65 75 min 2 x 1 M BP65 3 x 1 M BP65 4 x 1 M BP65 5 x 1 M BP65 90 min 1 x 1 M BP56 1 x 1 M BP84 1 x 1 M BP42 3 x 1 M BP65 4 x 1 M BP65 5 x 1 M BP65 6 x 1 M BP65 for IT environments Protect 1 M Classification VFI SS 111 acc to IEC 62040 3 Type power Part number UPS INPUT Input voltage auto detection Input voltage range without battery mode Frequency Current consumption max Power factor UPS OUTPUT Rated output voltage Frequency in battery mode Output current Transfer time at mains outage Voltage waveform Overload response online mode Crest factor BATTERY Nominal voltage Load characteristic Autonomy time Overload deep discharge protection COMMUNICATION Inte
10. BP 16 42 Plug amp play connection via a gt x Protect 1 100 BP 42 97 F J battery connection cable which is 3 x Protect 1 100 BP 60 134 protected against polarity reversal 1 x Protect 1 BP 20 19 47 10 29 6 19 Ready for connection battery 2 x Protect 1 BP 20 47 103 29 68 19 47 cabinets preassembled 3 x Protect 1 BP 20 78 177 47 103 34 62 Service life of the integrated 4 x Protect 1 BP 20 103 243 68 153 47 103 batteries 10 12 years according 5 x Protect 1 BP 20 138 312 85 202 63 138 to EUROBAT Protect 1 computer centers 10 20 kVA Classification VFI SS 111 acc to IEC 62040 3 Type power Part number Tower UPS INPUT Rated connected voltage Votlage range without battery mode Frequency auto selection Powerfactor Current consumption maximum UPS OUTPUT Rated AC voltage single phase Frequency in battery mode Output current at 230 Vac Transfer time at mains failure Voltage wave form Overload response Crest factor for non linear load Short Circuit Reaction BATTERY Rated voltage Load characteristic Autonomy time Overload deep discharge protection COMMUNICATION Interface Shutdown software on CD Alarms audible optical GENERAL DATA Efficiency total AC AC at full load Noise level 1 m distance Operating temperature Installation height EMC conformity Product safety Humidity Equipment colour Size approx W x H x D mm UPS unit Size approx W x H x D mm battery uni
11. Protect 3 M 2 0 uses an efficient communication module to collect all relevant data of the several modules over the internal network All information are displayed clearly on the LCD for easier UPS handling Battery management As far as operation and service are concerned intelligent moni toring via the display or system software as well as the possibility of using standard batteries make Protect 3 M 2 0 your preferred choice system e Manufacturer independent standard batteries for initial equipment or later replacement e Scheduled battery test for extended battery lifecycle e Intelligent battery management battery current measuring to provide useful charging amp discharging data for advanced battery management Additional features e Increased power factor pf gt 0 99 e Less pollution THDi lt 5 e Higher efficiency gt 94 at 25 load e ECO mode efficiency gt 97 e IGBT technology e Separate rectifier and dual bypass input e Full digital control DSP e PFC technology e Load depending fan speed e Multi language and big LCD for user friendly handling e Communication via SNMP adapter and RS232 RS485 interfaces e Communication interfaces Module lock Terminals ey as ee Ge n Tal E sized datacenters Protect 3 M 2 0 Classification VFI SS 111 acc to IEC 62040 3 Protect 3 M 80 Protect 3 M 120 Type power 80 kVA 120 kVA 64 KW 96 KW Max modules per ra
12. SS 211 acc to IEC 62040 3 Type power Part number BatteryPack UPS INPUT Input voltage Input voltage range without battery mode Frequency auto selection Current consumption max UPS OUTPUT Rated output voltage AVR technology Rated output voltage in battery mode Frequency in battery mode Output current at 230 Vac Transfer time at mains outage Voltage waveform Overload response at mains operation Overheat and short circuit protection BATTERY Type Rated voltage Autonomy time at rated load Overload deep discharge protection Recharge time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Failure indicators acoustical optical GENERAL DATA Audible noise 1 m distance Operating temperature range EMC conformity Product safety Data lines protection Humidity Installation height Number of outlets Equipment colour Size approx W x H x D mm UPS unit Size approx W x H x D mm battery unit Weight approx kg UPS unit Weight approx kg battery unit Shipment Certification only available until Q1 2011 B 750 B 1000 B 1500 B 2000 B 3000 750 VA 1000 VA 1500 VA 2000 VA 3000 VA 500 W 700 W 1050 W 1340 W 2100 W 600 000 3916 600 000 3917 600 000 3918 600 000 4095 600 000 3919 600 000 3921 600 000 3920 600 000 4921 220 Vac 230 Vac 240 Vac 161 184 276 Vac adjustable 50 Hz 60 Hz 5 Hz gt 40 Hz generator operation 5A 8A 10 A 10 A 16A
13. Vdc 240 Vdc yes yes yes yes 5h 5h 5h 7h RS232 for UPS configuration status and measurement levels SNMP AS 400 USB optional Included for all typical operating systems e g Windows Mac Linux Unix Sun etc single licence CompuWatch with a 5 fold network licence LED bar graph for UPS load and battery capacity indicators for mains failure overload battery discharge battery replace failure 85 88 gt 90 lt 45 dB A lt 50 dB A lt 55 dB A 0 40 C EN 62040 2 Class C2 EN 61000 3 2 EN 61000 3 3 EN 50091 2 EN 62040 1 RJ11 Phone Fax Modem RJ45 Ethernet 10 Mbit s 100 Mbit s 0 90 non condensing up to 1000 m at nominal load 4x IEC 320 C13 TCIEG 3207613 Permanent connection 1x IEC 320 C19 4x IEC 320 C13 Blackline 482 6 x 88 x 450 82 6 x 88 x 450 482 6 x 132 x 600 integrated 482 6 x 88 x 450 482 6 x 132 x 600 16 5 kg 10 kg 11 kg 18 kg 29 kg 29 kg 64 kg Mains Cord 3 load cords type C 1000 C 2000 C 3000 communication cable management software CompuWatch user manual CE Protect D Protect D Efficient high performance UPS ideal Valuable features and easy control e VFI topology online double conversion protects against all mains power disturbances e 20 higher available power by 0 9 lagging power factor e Increase of efficiency through ECO and ECO mode e Improved battery charging technology for optimal battery lifetime e Hot swappable batteries easy exchange
14. computer Owing to its two part design the connection cables can be flexibly housed The first part serves as a power supply for the computer printer and monitor The other part of the surge protective conductor has a power switch for disconnecting the TwinPower from the network With this feature all connected devices do not consume electricity when in standby Furthermore the desk unit has 3 other power sockets Cell phones and MP3 players can be charged using its two protected USB ports Key features e Divided surge protector one part always powered e Overall 4 3 protected sockets e 2 protected USB chargers e Easily accessible power switch e Surge protection up to 36 000 A amp 10 years warranty 2 protected USB chargers easy accessible power switch controls both parts of the TwinPower Part number Protect TwinPower 600 000 7749 Mm is UPS technology Outage blackouts gt 10ms Sags brownouts Dynamic overvoltage Undervoltage continuous Overvoltage continuous Transients Surges Frequency variations Voltage distortions bursts Voltage harmonics Lightning Uninterruptible power supply Mains voltage variations occur more often than expected The consequences of this are crashes loss of data and cost intensive downtimes The solution is an uninterruptible power supply UPS which offers various level of protection There are three different UPS topologies offering differ
15. display of important aspects of the operating status like autonomy time lt 40 dB A lt 45 dB A AC operation lt 40 dB A fanless speed controlled fan 0 40 C 0 90 without condensation 3 1 x IEC 320 C13 4 2 x IEC 320 C13 EN 62040 2 Class C2 EN 61000 3 2 EN 61000 3 3 EN 62040 1 1 RJ11 RJ45 add network Ethernet 10 amp 100 Mbps Blackline RJ11 phone fax modem 100 x 140 x 330 145 x 205 x 405 6 kg 6 5 kg 9 5 kg 10 kg Mains connection 2 device connecting cables management software CompuWatch CD incl 1 network licence USB and RS232 communication cable operating instructions CE Protect B Protect B Uninterruptible security with sine wave Protect B operator panel Battery capacity UPS capacity utilisation Mains operation Battery operation Operating mode UPS On Off button UPS test switch Configuration Confirmation button LEDs for fault diagnosis Rated output voltage Protect B 1500 B 2000 Rear view space for AC output distribution box AC output communication slot EPO USB port RS232 Surge protection g 1 RJ11 RJ45 for AC input External battery connector fax modem network Protect B Tower autonomy time full halfload in min 750VA 1000VA 1500VA 2000VA 3000 VA Height 2 U RS232 AC Output Protect B Rack High level flexibility intelligent functions e Modern VI line interactive protection technology with sine wave output v
16. external manual bypass switch an optional add on for the Protect B B PRO C C R D 1 and 1 M series of UPS systems is used to bypass a UPS for example to carry out mainte nance without interrupting the supply of power to connected loads Besides simple bypass operation it features an additional setting to enable UPS testing The switch is equipped with indi vidually protected power connectors to supply power to loads directly The external manual bypass switch has three settings 1 UPS mode Loads are supplied with power via the UPS 2 Service mode Connected loads are powered directly from the mains supply This setting also enables the UPS to be tested 3 Bypass mode In this mode loads are powered directly from the mains supply The attached UPS is fully disconnected from the circuit and can be removed for maintenance or replace ment MBS 2000 600 000 3039 MBS 3000 600 000 3040 MBS 6000 Rack 600 000 5205 MBS 10000 600 000 7684 MBS 24000 100 000 2021 Accessories Hardware Power Distribution Box Parallel board manual bypass and distribution With the compact parallel switch panel users can set up a paral lel system comprising up to three Protect C 6000 C 10000 or up to three Protect 1 100 1 150 or 1 200 units without needing to restructure an existing low voltage main distribution system Combining up to 24 separately protected ready made circuits in an output distribution unit bui
17. lines protection Humidity Installation height Number of outlets Tower Equipment colour Size approx W x H x d mm Tower Battery Weight approx Tower Battery Shipment Certification C 1000 C 2000 C 3000 C 6000 C 10000 1000 VA 2000 VA 3000 VA 6000 VA 10000 VA 700 W 1400 W 2100 W 4200 W 7000 W can be operated in parallel mode 600 000 5735 600 000 5736 600 000 5738 600 000 5877 600 000 5878 600 000 5739 600 000 5740 600 000 5740 600 000 5879 600 000 5880 600 000 4337 600 000 4338 600 000 4339 600 000 4340 600 000 4341 220 Vac 230 Vac 240 Vac 160 300 Vac 176 276 Vac 50 Hz 60 Hz 4 Hz fo OSE 0 98 7A 10 A 16A 31A 50 A 220 Vac 230 Vac 240 Vac 2 220 Vac 230 Vac 240 Vac 1 50 Hz 60 Hz 0 2 50 Hz 60 Hz 0 1 4 3 A 8 7 A 13 A 26 A 43 4 A O ms zero transfer sinusoidal THD lt 4 140 30 s 150 300 ms 130 10 min gt 130 1 s subsequent transfer to bypass mode 3al short circuit proof sealed maintenance free 36 Vdc 96 Vdc 240 Vdc yes yes yes yes yes 5h 5h 5h 7h 7h RS232 for UPS configuration status and measurement levels SNMP AS 400 USB optional Included for all typical operating systems e g Windows Mac Linux Unix Sun etc single licence CompuWatch with a 5 fold network licence LED bar graph for UPS load and battery capacity indicators for mains failure overload battery discharge battery replace failure 85 88 gt 90 lt 45 dB A lt 50 dB A lt 55 dB A
18. outlets are fitted with child locks e Prepared for wall mounting e LEDs indicating operating state and active surge protection e Surge protection up to 36 000 A amp 10 years warranty Protect Basic GE7 Cable fixture avoids tangled cables Protect Travel Protection for travelling with additional USB charger The Protect Travel provides surge protection in the smallest of spaces This makes it ideal for travelling or for applications in confined spaces Often the power quality in the country of travel is not sufficiently guaranteed Be on the safe side and protect your laptop cell phone or digital camera against overvoltage while on the move With the additional USB charger unit you save on extra chargers Key features e 3 surge protected sockets e 2 USB chargers for cell phones or MP3 players e Indicator shows active surge protection e Compact dimensions for travelling e 90 degrees rotating mains input cord e Surge protection up to 36 000 A amp 10 years warranty Protect Travel fits perfect into travel bags Surge protection Part number Protect Basic GE6 600 000 7194 Protect Basic GE7 600 000 7196 Part number Protect Travel 600 000 7747 Surge protection Protect Office Compact protection for PC and peripheral equipment Protect Office is the compact power distribution for your desktop The 3 power outlets and network ports provide complete computer protection During the develop
19. via flip over cover e Additional Battery Packs for individual scaling of autonomy times e Expansion slot for communication cards parallel operation via RS232 USB and SNMP e Maximize your rack space as the UPS is only 2U including integrated batteries e Controllable UPS outlets with innovative lock mechanism prevents accidental disconnection of connected cables e Graphical display shows UPS parameters easy configuration of settings via control panel e Data logger synchronized to real time clock e Programmable potential free contact amp EPO switch e Frequency converter mode e Free 36 months warranty on UPS and battery with advanced replacement service registration required Display of UPS input Display of current UPS mode Display of UPS output Indicator UPS mode Control panel Fan 4 x IEC320 C13 outputs EPO mains input USB amp RS232 communication interfaces 2 x 2 controllable IEC320 C13 outlets expansion slot for potential free ae communication cards contact Protect D cos 0 9 lagging autonomy time full halfload in min 1000 VA 1500 VA 2000 VA 3000 VA Standard autonomy time 6 16 55 14 6 16 5 3 5 9 1 additional BatteryPack 31 68 25 61 33 71 18 45 2 additional BatteryPacks 51 110 46 112 59 129 34 84 3 additional BatteryPacks 82 192 69 172 88 183 53 122 4 additional BatteryPacks 100 246 90 221 119 260 69 165 extension slot lockable outlets e easy batter
20. voltage 384 Max charging voltage in V 461 Total harmonic distortion i 6 12 12 12 12 12 12 12 12 standard option pulse INVERTER UNIT Nominal DC voltage min max in V 307 461 Nominal AC voltage in V 3 x 400 Adjustable min max in V 380 415 Static response lt 1 Dynamic response 0 100 0 lt 5 Correction time 2 ms Frequency in Hz 50 60 Frequency tolerance without mains 0 1 Frequency synchronisation range z1 Yo Power factor range cos cap 1 ind Output phase current in A 231 318 ERA 578 723 867 1156 1445 Voltage wave form Sinus Voltage distortion 2 amp 3 Yo Crest factor Sa Overload response for 1 min 150 Overload response for 10 min 125 Short circuit response of typical 300 STATIC BYPASS SWITCH AC voltage min nominal max in V 3 x 380 400 415 Frequency in Hz 50 60 Nominal power in kVA 160 220 300 400 500 600 800 1000 Overload 500 GENERAL DATA Efficiency total up to 94 ECOpx up to 98 Noise level in dB A depending on type gt 69 EMC compatibility acc EN 60040 2 G2 Product safety EN 62040 1 1 Air cooling with redundant yes monitored fans Operating temperature range min max in C 5 40 Storage temperature range min max in C 30 75 Installation height NN 1000 m Protection degree acc IEC 529 EN 60529 IP 20 Equipment colour RAL 7035 DIMENSIONS Height standard device in mm 1910 1915 1925 1915 1915 1960 2210 Height with max options in mm 2015 2210 2210 2210 2210 2210 2210 Width in mm 120
21. 0 40 C EN 62040 2 Class C2 EN 61000 3 2 EN 61000 3 3 EN 50091 2 EN 62040 1 RJ11 Phone Fax Modem RJ45 Ethernet 10 Mbit s 100 Mbit s 0 90 non condensing up to 1000 m at nominal load 4x IEC 320 C13 6 x IEC 320 C13 4 x IEC 320 C13 Terminal block 1 x IEC 320 C19 Blackline 145 x 220 x 400 192 x 340 x 460 260 x 717 x 570 integrated not at S version same dimensions as tower 15 kq 34 kg 35 kg 90 kg 93 kg 19 kg 49 kg 49 kg 86 kg 89kg Mains Cord 3 load cords type C 1000 C 2000 C 3000 communication cable management software CompuWatch user manual CE Protect C Rack Protect C Rack High performance UPS system for IT Due to true online double conversion technology Protect C is well suited for mission critical appli cations such as sensitive networks small computer centers Intranet and Internet servers telecom applications as well as for industrial applications The Protect C employs VFI topology to protect loads against all public grid disturbances On the input side sine wave shape current consumption is achieved for all load conditions High integrated circuits reduce the number of electric connections and components as well as a robust IGBI mod ule the result less and more robust components increasing reliability An automatic bypass provides security during overload Reliable technology for your safety e VFl topology double conversion Protects against all mains power disturbances
22. 0 1200 1500 2100 2100 2400 4050 Depth in mm 960 960 960 960 960 960 1060 Weight in kg 1670 1950 2030 3200 3480 3800 5700 CompuWatch Software solutions compuWatch the Shutdown and UPS management software for automation in data processing Based on the TCP IP network protocol CompuWatch is applicable to heterogeneous networks where servers and computer systems with diverse operating systems require a safe i e where all open files are closed and automatic shutdown process for particular situations It carries out its functions by passing information through security mechanisms to all UPS protected servers and computer systems by way of an intelligent UPS to server communications interface as well as the existing network topology Appropriate software modules in these servers and computer systems make it possible for them to react accordingly A terraced shutdown sequence can be achieved by configuring these software modules on the affected servers All CompuWatch modules run as service or background processes Individual procedures can be launched by a shell script or batch programming techniques The CompuWatch client a graphic front end for all Microsoft Windows operating systems permits all UPS systems connected to the network to be monitored and controlled Aside from this a scheduler can also be used to control the entire network Products from AEG Power Solutions provide a total security solution for network power from
23. 0 276 Vac 50 Hz 60 Hz 10 gt 0 99 THDi lt 8 5A 7 5 A 10 A 14 A 208 Vac 220 Vac 230 Vac default 240 Vac 2 50 Hz 60 Hz 0 25 Hz 4 3 A 6 5 A 8 7 A 13 A O ms without interruption sinusoidal distortion THD lt 3 lt 130 for 5 min 130 150 for 15 s lt 130 for 12 s 130 150 for 2 s Sie short circuit proof 4 x In for 100ms sealed maintenance free lead acid integrated hot swappable 36 Vdc 48 Vdc 72 Vde temperature compensated with discharge protection autom battery test amp battery pack detection 3 RS232 USB communication slot can be used parallel to RS232 USB terminals for EPO and a potential free contact five network licences included Windows Linux Mac Unix Sun etc 3 LEDs arranged for quick operational status check detailled indication via LCD display alarms at mains failure overload battery discharged replace battery fan fault RTC event logger 95 98 gt 88 gt 89 gt 90 0 to 40 C lt 45 dB A lt 52 dB A lt 95 without condensation EN 62040 2 Class C1 EN 61000 3 2 EN 61000 3 3 EN 62040 1 up to 3000 m at full load 6 x IEC320 C13 2 2 8 x IEC 320 C13 2 2 6 x IEC 320 C13 3 3 1x IEC 320 C19 Metal case with Aluminium front 482 6 19 x 88 2U x 430 482 6 19 x 88 2U x 600 482 6 19 x 88 2U x 430 482 6 19 x 88 2U x 600 16 kg USES co 29 kg 29 5 kg 23 kg 28 kg 41 kg 41 kg mains input cable 1 x EU 1 x UK UPS
24. 1665 x 975 operating buttons ON OFF UPS status LEDs e normal EPO e battery e bypass e failure Display Protect 3 M Protect 3 33 Protect 3 33 Online UPS system for datacenters a Robust and Reliable Protect 3 33 is extremely robust both electrically and mechani cally It is custom designed for use in harsh industrial environments The UPS offers a very high level of protection for users and connected equipment e High intermittent overload capacity e High level short circuit strength e N conductor with full loading capacity 3 phase systems e Excellent dynamic response can easily handle high cyclic loads Exact solutions engineered for each application e Single systems e Parallel systems e Other input output voltages Additional system equipment e Bypass transformer e Voltage stabilizer e Maintenance Bypass Switch e AC distribution panels e Battery cubicles e Explosion proof battery circuit breaker enclosures Unique Design e Parallel operation for capacity and performance Flexible Multi Master Technology and CAN bus communication enables up to 8 UPS to be connected in parallel for increased power redundancy or system upgrade e Parallel UPS can be operated with a central battery e Three microprocessor control system These microprocessors simultaneously monitor and control the rectifier inverter and static switch units This control has been specially designed to provide a problem free p
25. 520 440 19 x 88 2 U x 640 14 6 Syl 21 8 14 4 29 5 BP 29 2975 mains input cord 1 x EU 1 x UK CE Protect C Protect C High performance UPS system for IT and el Reliable technology for your safety e VFl topology double conversion Protects against all mains power disturbances e Microprocessor control DSP guarantees highest availability e Sine wave shaped current consumption High frequency PWM with IGBTs e Automatic bypass additional integrated service bypass at 6 and 10 kVA tower e Redundancy due to n x configuration at 6 and 10 kVA increase in power output safety and availability e Expansion slot for extension cards SNMP relay card USB potential free contacts e Free 36 months warranty on UPS and battery with advanced replacement service registration required fan RS232 communication interface expansion slot for communication cards Protect C Parallel operations Protect C 6000 and C 10000 are also able to be switched parallel Demand for greater availability by providing an active redundancy as well as a need for increased output power is met here The combined power increase in connection with active redundancy can be achieved by the parallel switch having the ability to connect a maximum of 3 devices The key factors are meeting the highest requirements for safety and availability as well as maintaining a cost efficient implementation Autonomy times Protect C Stand
26. Saft Power Systems and development of a wide range of innovative battery charging equipment and power supply systems 1945 Establishment of the AEG plant in Warstein Belecke with 25 employees CONTENT P 4 11 PRODUCT OVERVIEW P 12 15 SURGE PROTECTION Protect Basic Travel Office Business Protect Entertainment TwinPower P 16 17 UPS TOPOLOGIES P 18 21 UPS FOR SOHOS Protect Home Protect A P 22 29 UPS FOR SMALL AND MEDIUM IT Protect B Protect B PRO Protect C Protect C Rack P 30 35 UPS FOR MEDIUM DATACENTER Protect D Protect 1 Protect 1 M P 36 37 COMBINATION ARCHITECTURE P 38 43 UPS FOR LARGE DATACENTER Protect 3 M Protect 3 33 Protect 4 33 P 44 45 SOFTWARE SOLUTIONS P 46 49 UPS ACCESSORIES P 50 51 SERVICE PACKAGES Surge protectors HOME Protect Basic Protect Entertainment Protect TwinPower Protection for all Intelligent protection for Security for various Standard applications entertainment equipment applications with with Master Slave Function protected USB chargers EQUIPMENT Standard earthing sockets 6 GE6 7 GE7 6 4 1 EU sockets z 2 Power switch v v USB charger 2 Network protection j v Special features cable fixture antenna separated Basic GE7 connector surge protector APPLICATIONS Telephone systems router v v Televisions amp receivers v Game consoles v Computer amp periphery v v Hifi amp speakers
27. a single source the Total Network Security Solution Total Network Security Solution Special features e Software in client server technology e Integration as a background process e Supports multi server shutdown in homogeneous and heterogeneous networks Example The Figure illustrates a heterogeneous network with a Windows NT server configured as the master and various slave servers that have other operating systems The potential to implement the automation of shutdown and reboot procedures for the entire network including the UPS is inherent to these products This er means that during a e System activities can be programmed via scheduler and configured by event manager e Monitoring UPS devices locally and remotely via network e Selectable bar graphs for measured values e Support of the wake up on LAN function for sequential reboot e Customizable batch files and scripts for the shutdown Patented Conimanch procedure e Alerting of events via network messages e mails and SMS UPS Configuration ee BE e SSL encryption for multi server shutdown e Logging of all events in a log file LP am Fn mM a sa e Visit www aegpartnernet com for an overview about all supported operating systems a ee S iB a LE ti i maa Deed Enable Disable Bu Bromk bowie Shad Tie i Hah caine l E zem Fe power outage of long duration the entire data net can be safely shut down and turned off
28. ac 10 3 free running 50 Hz 60 Hz 1Hz 3 2 A 4 3 A 6 1 A 7 8 A 10 A 13A 2 6 ms typical 8 ms max sinusoidal lt 120 for 5min 120 150 for 10s gt 150 for 1s lt 110 for 1min 110 150 for 10s 150 200 for 500ms sealed maintenance free hot swappable yes yes yes no external yes yes 24 Vdc 48 Vdc 72 Vdc temperature compensated with overload and deep discharge protection automatic battery test batterypack detection 10 28 1xBP 26 62 2xBP 4 14 4 11 44 100 3xBP 4 5 10 5 95 95 55 135 6h LCD display with digital indication of UPS relevant values RS232 amp USB with status notfication and UPS figures additional communication slot in parallel mode SNMP relay card input contact for emergency power off 5 network licenses for all common OS e g Windows Linux Mac 3 LED indicators show UPS status detailed indication via LCD display mains failure overload battery discharge battery replace fan failure gt 97 gt 90 lt 45 dB A lt 55 dB A lt 40 dB A lt 45 dB A 0 bis 40 C 20 bis 50 C EN 62040 2 Class C1 EN 61000 3 2 EN 61000 3 3 EN 62040 1 RJ11 Phone Fax Modem RJ45 Ethernet 10 Mbit s 100 Mbit s 0 90 non condensing operation up to 1000m at full load air freight up to 10600 m IEC 320 C14 IEC 320 C20 8 4 Tas ox IECS2Z0 C13 6 ECGS 20 Gils 1 x IEC320 C19 black metal case silver front 440 19 x 88 2 U x 420 440 19 x 88 2 U x
29. ard autonomy time 1 additional BatteryPack 2 additional BatteryPacks 3 additional BatteryPacks 4 additional BatteryPacks port for parallel operation external battery connector input fuse manual bypass switch mains input amp outlets via connection terminal Protect C 10 kVA Rear view autonomy time full halfload in min 1000 VA 2000 VA 3000 VA 6000 VA 10000 VA 6 20 10 30 5 16 8 26 5 16 38 97 55 130 30 85 26 67 16 42 76 170 106 237 60 149 47 112 27 60 60 157 42 97 94 203 53 118 ectronic data processing in Protect C medium sized companies Classification VFI SS 211 acc to IEC 62040 3 Classification VFI SS 111 acc to IEC 62040 3 Type rating Part number Tower Part number BatteryPack Part number Tower S Version UPS INPUT Input voltage Input voltage range without battery mode Frequency Power factor Current consumption max UPS OUTPUT Rated output voltage Frequency in battery mode Output current at 230 Vac Transfer time at mains outage Voltage waveform Overload response online mode Crest factor Short circuit response BATTERY Type Rated voltage Overload deep discharge protection Recharge time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Failure indicators acoustical optical GENERAL DATA Efficiency total Audible noise 1 m distance Operating temperature range EMC conformity Product safety Data
30. ay s facilities we understand that optimising efficiency is utilise low impact cost efficient technologies as secondary a critical step forward in rising to meet these challenges sources of power Including That s why we re developing Combination Architecture a e Fuel cells range of next generation UPS systems capable of harnessing e SuperCaps ultracapacitors renewable and alternative energy sources and storage By e Solar cell and wind power energy using lower carbon alternatives our unique Combination SuperCaps Combinationey Architecture The SuperCaps Advantage Combination Architecture from AEG Power Solutions brings you the SuperCaps advantage to deliver a highly effective energy storage solution for data centres and mission critical power applications SuperCaps or ultracapacitors provide an environmentally effective option for businesses that are concerned with reducing energy consumption lowering total cost of ownership and carbon footprint SuperCaps offer the functionality life cycle costs and reliability characteristics required for use in the power systems which ensure continuous availability Their high power density is ideally suited to supply bridge power for short periods of around 30 to 100 seconds while secondary generation systems come up to speed On the other hand battery banks are typically sized to deliver power over longer periods In fact if sized for the actual du
31. bled plus a shutdown contact to enable a remote UPS shutdown in the event of an emergency The remote panel can be installed at a distance of up to 500 meters Data and power are supplied to the remote panel over a conventional patch cable The remote panel is available for Protect C Tower 6 kVA and higher Protect 1 and Protect 1 M UPS units Remote Panel 600 000 5881 Hardware Extensions amp accessories Power distribution units Power distribution for professional datacenters These power distribution units are designed to distribute power from UPS outlets to multiple connected loads Various models are available with a choice of grounded IEC320 C13 and C19 sockets for connecting equipment The sockets are protected against overloading either indi vidually or in pairs depending on the connector type The connection options provide an effective means of defining selection criteria to meet required power down condi tions LEDs indicate the current operating state Thanks to slot in rack flanges the PDUs are easy to install in a standard rack chassis For flexibility the flanges can be removed for desktop use The PDUs have robust aluminum enclosures offering exceptional rigidity and durability PDU 10 1 600 000 6684 PDU 16 1 600 000 6829 PDU 10 2 600 000 6831 PDU 16 2 600 000 6832 IEC Distribution Bar 600 000 9254 Manual Bypass Switch Manual bypass switch for maintenance and battery tests The
32. centers Protect 3 33 Protect 4 33 10 to 120 kVA 160 to 1000 kVA High availability UPS for hosting file servers High availability UPS for all critical applications in facility workstations and data centers also for their control systems data centers telecommunication internet integration in complex networks nodes banks and insurances 40 ae 10 120 kVA 160 1000 kVA VFI double conversion VFI double conversion 3 ph 3 ph 3 ph 3 ph yes yes free configurable free configurable wu SuUperCaps SuperCaps have the ability to give fast peak power for indefinite cycles they can be charged or discharged several times and also have a long lifetime up to 20 years More efficient than conventional batteries they do not release any heat during discharge and are up to 95 efficient in application Additionally they do not require special storage conditions and maintenance for assured operation Their scalable and modular nature makes SuperCaps a compelling proposition for data center applications Page 37 MH 12 Surge protection YEARS WARRANTY j When voltage rises AEG Surge protection Power Solutions Surges can be caused for example by lightning striking near your premises Lightning induces voltage surges in conductors and cables that can damage any connected equipment Switching in households with conventional power supplies of fluorescent lamps for example can also cause surges in the wiring system
33. ck 4 6 UPS INPUT Input voltage 400 230Vac Frequency 50 60Hz Auto Selectable Frequency range 5 Hz Power factor gt 0 99 Full Load THD i lt 5 UPS OUTPUT Rated output voltage 400 230Vac Frequency 50 60Hz 0 05 THD v lt 3 Transfer time at mains outage O ms zero transfer sinusoidal lt 125 for 10 min lt 150 for 1 min gt 150 for 0 3 sec Crest factor 25 1 BATTERY Nominal voltage Voltage waveform Overload response online mode 240 Vdc Free to choose runtime extension with Autonomy time a additional external battery Overload deep discharge protection yes COMMUNICATION eae RS232 RS485 for status and measurement values communication slot for pot free contacts and SNMP adapter LCD with digital information of input and output parameters voltage frequency power etc battery Failure indicators acoustic optical lop parameter etc LED for status and main failures GENERAL DATA Efficiency total Audible noise 1 m distance lt 95 lt 98 in ECO Mode 64 to 69 dBA depends on load Operating temperature range 0 40 C EMC conformity EN62040 2 Class C3 EN 61000 6 2 EN 61000 6 4 Product safety EN62040 1 Humidity lt 90 Installation height up to 3000 m at nominal load Equipment colour RAL 7035 WEIGHTS AND DIMENSIONS Weight approx module 30 kg Empty rack 139 kg 204 kg with maximum modules 259 kg 384 kg Size approx W x H x D mm 520 x 165x910 520 x
34. d for Protect C C R 1 1 M 600 000 3932 Relay card for Protect B PRO 600 000 9252 Relay card for Protect D 600 000 9253 SiteManager Network based UPS management device The SiteManager is a professional grade monitoring sys tem The 19 rack unit can be used to monitor equipment cabinets and rooms as well as industrial applications With its plug and play support for a range of sensors and actuators the SiteManager Is exceptionally quick and easy to install It has eight digital ports that accept an extensive range of contact sensors including smoke detectors motion detectors and door contacts It additionally includes eight inputs for analog signals 0 10V Each input is individually configurable to sup port everything from temperature and humidity sensors to custom sensor devices There are also eight separate relay outputs for controlling loads These outputs can be controlled either manually by users or automatically in response to defined events All alarm states are indicated on the front panel be light emitting diodes The electri cal connections are located on the monitoring unit s rear panel SiteManager 600 000 7349 Temperature sensor 800 002 2489 Smoke detector 800 002 2495 Motion detector 800 002 2494 Audible alarm 600 000 7361 Environment Manager Management device for several environment sensors The Environment Manager is a universal sensor management device designed as a system a
35. dd on for the SNMP PRO Adapter It can manage up to eight analog sensors four digital contacts and four digital switches simultaneously The device can also work with other kinds of sensor units for humidity pressure tank fill levels and chemical concentrations for example pro vided the signal voltages from the attached sensors are within defined values 0 10V for analog inputs 48V 500mA for digital inputs outputs The digital outputs can be configured for a default state of open or closed Sensors are simply connected to a free RJ11 port If more than four sensor devices need to be attached sensors are available that are equipped with an expansion connector allowing multiple sensors to be connected to one another If all the RJ11 ports are occupied splitters can be used to provide additional ports Environment Manager 800 002 2488 Temperature sensor 800 002 2489 Motion detector 800 002 2494 Smoke detector 800 002 2495 Audible alarm 600 000 7361 Accessories Communication SNMP pro Adapter UPS management device via network Available in two versions the SNMP adapter enables users to monitor the status of UPS units via the Web or WAP It can also initiate a staggered shutdown of key servers if the need arises and can restart the servers via wake on LAN providing auto matic system shutdown and reboot capabilities In addition to these features the adapter has an integrated RFC1628 compliant SNMP agent allowing
36. ent protection levels against all 10 types of mains disruption and variation Optimal protection for every application The VFD technology protects against the mains variations caused by network disruptions brownouts and voltage peaks The VI technology protects against the most common mains variations It s a good compromise between protection and costs The highly reliable VFI technology offers the best protection against mains disruptions and variantions This technology provides a clean and secure supply of power for all critical applications and sensitive hardware acc to IEC 62040 3 offline Advantages Transfer unit e most compact solutions possible e high efficiency low running costs e low cost solutions Rectifier Battery Inverter acc to IEC 62040 3 line interactive Advantages e high efficiency low running costs e extremely wide input voltage j Transfer unit Rectifier Battery Inverter Transformer e robust concept acc to IEC 62040 3 online double conversion Advantages e no transfer gap e protection against all supply mains voltage disturbances e sine wave input current e converter mode possible Battery UPS e internal redundancy by addtional bypass UPS technologies Disadvantages e transfer gap some ms e load is fed by unfiltered voltage no correction by the inverter e output voltage often not sinusoidal Disadvantages e transfer gap some ms
37. f the UPS values e Definable shutdown processes can be triggered in a time or event controlled manner via shell script e Event controlled transmission of messages via e mail and SMS e Communication via Novell interface RS232 network and USB e Support for all major operating systems e further information can be found on page 44 Available with german french and UK sockets Compact UPS IT equipment Protect B Protect B PRO 750 to 3000 VA 750 to 3000 VA Rack or tower for server and network components Efficient Rack Tower UPS with sinusoidal output with sinusoidal output for small servers and networks 22 24 0 75 3 kVA 0 75 3 kVA VI Line interactive VI Line interactive 1 ph 1 ph 1 ph 1 phx no no 5 65 4 44 UPS topologies VFD offline UPS output depends upon supply mains voltage and frequency variations Advantages compact dimensions possible low cost solution VI line interactive UPS output depends upon supply mains frequency variations but supply voltage are conditioned independent Advantages high efficiency low running costs extreme wide input voltage VFI onine UPS output is independent of supply mains voltage and frequency variations Advantages highest availability protection against all supply mains voltage disturbances frequency converter mode possible ME Compact UPS medium sized IT facilities meen hia 7 oo a Protect C Protect C Rack
38. ion Frequency automatic detection UPS OUTPUT Rated output voltage AVR technology Rated output voltage in battery operation Frequency in battery operation Nominal output current at 230 Vac Changeover time in the event of mains failure Voltage curve Overload protection BATTERY Type Autonomy time for 1 PC with 17 TFT Exhaustive discharge protection protection against excess load Charging time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Alarms acoustic optical Status display GENERAL DATA Inherent noise 1 m distance Operating temperature range Relative humidity Load outputs EMC conformity Product safety Overvoltage protection for data lines Housing colour Dimensions approx W x H x D mm Weight approx Scope of delivery Conformity A 500 A 700 A 1000 A 1400 500 VA 700 VA 1000 VA 1400 VA 300 W 420 W 600 W 840 W 600 000 6435 600 000 6436 600 000 6437 600 000 6438 220 Vac 230 Vac 240 Vac 160 290 Vac 170 280 Vac 50 Hz 60 Hz 5 Hz 230 Vac 10 50 Hz 60 Hz 1 Hz 2 2 A 3 0A 43A 6 1 A 2 6 ms typical approximated sinewave yes yes yes yes sealed maintenance free 15 min 20 min 30 min 40 min yes yes yes yes 8 hrs USB and RS232 with status messages and measured values included in delivery for all major operating systems e g Windows Linux Mac mains failure overload battery discharged replace battery fault LCD with additional
39. isation range Power factor range cos Output phase current in A 14 Voltage wave form Voltage distortion Crest factor Overload response 1 min Overload response 10 min Short circuit response of laom typical STATIC BYPASS SWITCH AC voltage min nominal max Frequency Nominal power in kVA 10 Overload GENERAL DATA Efficiency total up to Eco px option Noise level depending on type EMC compatibility acc EN 60040 2 Air cooling with redundant and monitored fans Operating temperature range min max Storage temperature range min max Installation height NN Protection degree acc IEC 529 EN 60529 Equipment colour WEIGHTS AND DIMENSIONS Height standard UPS mm 1710 Height with max options mm 1815 Width mm 600 Depth mm 735 Weight kg 350 3 33 20 20 33 41 6 pulse Filter 29 20 1710 1815 600 735 370 3 33 30 30 50 62 6 pulse Filter 43 30 1710 1815 600 735 450 3 33 40 40 60 3 x 400 V 340 V 460 V 45 66 Hz 66 98 82 123 IU 384 V 461 V 6 pulse 6 pulse Filter Filter 307 V 461 V 3 x 400 V 380 V 415 V lt 1 lt 5 2 ms 50 60 Hz 0 1 1 cap 1 ind 58 87 sinus lt 3 Se 150 125 300 3 x 380 V 400 V 415 V 50 60 Hz 40 60 500 94 up to 98 lt 55 65 dB A GZ Yes 5 C 40 C 30 C 75 C 1000 m IP20 RAL 7035 1710 1710 1815 1815 600 750 735 735 470 550 3 33 60 3 33 80 80
40. k licence LCD with digital information of input and output parameters voltage frequency power etc battery parameter incl failure diagnosis by password protected level LED for status and main failures gt 89 gt 88 lt 55 dB A lt 62 dB A 0 40 C EN 62040 2 Class C2 EN 62040 1 1 20 90 up to 1500 m at nominal load Black 442 x 965 x 700 chassis module 405 x 87 x 530 442 x 965 x 700 75 kg chassis 15 kg each module MBP 28 160 kg MBP 42 200 kg MBP 56 255 kg MBP 65 270 kg MBP 84 335 kg Parallel operation cable communication cable management software CompuWatch CD user manual CE m9 36 Combination Architecture Next generation UPS for a new world Combination Architecture Ever tightening controls on carbon emissions The need for Architecture systems will deliver what you need most ever greater computing capacity And the challenge of a way to drive down infrastructure operating costs boost controlling power costs Always at the forefront of power computing capacity and reduce carbon footprint to help innovation AEG Power Solutions is first to recognise the make our world greener and cleaner growing pressure on data centres to control power consumption and increase energy efficiency And with UPS AEG Power Solutions Combination Architecture includes systems accounting for a substantial part of energy used by innovative standby and power protection systems that can tod
41. lt into a parallel switch panel the PDB box eliminates the need to set up or reorganize a sub distribution system Offering active redundancy and designed for use with the Protect C range of single phase UPS units up to 30 kVA or 20 kVA and the Protect 1 range of three phase input UPS units up to 60 kVA or 40 kVA the switch panel allows users to connect devices in parallel for enhanced performance and single or multiple redundancy Each UPS unit can be disconnected from the mains supply on the input side and from the protected busbar with out interrupting the supply of power to connected loads In addi tion the manual bypass can disconnect the entire parallel UPS system for maintenance for example without cutting power to attached devices A remote signaling contact indicates the current operating status PDB for Protect C 100 000 1852 PDB for Protect 1 100 000 1853 Accessories Communication Communication Extensions amp accessories Part numbers Relay card Communication device for AS 400 This relay card is an option for UPS series Protect B B PRO C C R D 1 and 1 M and enables the communication via potential free contacts The contacts can be confi gured as open and shut The status notifications will be transmitted by a 9 pin Sub D socket The relay cards are optimized for the IBM AS400 but can also be used for other applications Relay card for Protect B from 1500 VA 600 000 5196 Relay car
42. ltage range without battery mode Frequency auto selection Current consumption max UPS OUTPUT Rated output voltage AVR technology Frequency in battery mode Output current on 230Vac Transfer time at mains outage Voltage waveform Overload response VI operation Overload response battery operation BATTERY Type integrated Rated voltage Battery management Autonomy time in min full half load cos phi 0 9lag Charging time to 90 of rated capacity COMMUNICATION User interface Interface Shutdown software on CD Failure indicators acoustical optical GENERAL DATA Efficiency in ECO mode at whole AVR range Audible noise at 1 m distance max Ditto at ECO mode and max 70 load Operating temperature range Storage temperature range EMC conformity Product safety Data lines protection Humidity Installation height transportation Mains input Number of outlets of them controllable via connectors Equipment colour Size approx W x Hx D mm Net weight approx kg Shipment Certification B 750 PRO B 1000 PRO B 1400 PRO B 1800 PRO B 2300 PRO B 3000 PRO 750 VA 1000 VA 1400 VA 1800 VA 2300 VA 3000 VA 675 W 900 W 1260 W 1620 W 2070 W 2700 W 600 000 8428 600 000 8422 600 000 8429 BP 600 000 8424 600 000 8426 600 000 8431 600 000 8432 220 Vac 230 Vac 240 Vac 182 Vac to 280 Vac 50 Hz 60 Hz 5Hz 3 6 A 4 8 A 6 7 A 9 8A 11 A 14 5 A 220 Vac 230 Vac Voreinstellung 240 V
43. management software CompuWatch CD communication cables RS232 amp USB operating and safety instructions device connection cables 3 x IEC320 C13 D 1000 D 2000 3x IEC320 C13 1 x IEC320 C19 D 3000 CE Protect 1 Protect 1 Online UPS systems for networks and e True online UPS including static bypass double conversion VFl technology e Power range 10 15 20 kVA space saving design n x technology DSP controlled to increase output power and or for redundancy e State of the art High reliability and efficiency by digital signal processing DSP CAN bus system and high frequency IGBT technology e Uses battery systems with up to ten years battery service life according to EUROBAT e Communication via RS232 expansion slot for e g relaycard and SNMP e 24 months warranty with pre exchange service e Free 36 months warranty on UPS and expansion slot for ae battery with advanced replacement service communication cards registration required LV Distribution UPS Input y y y illii Parallel A A Bypass plus UPS Distribution Protect 1 in parallel operation Rear view Protect 1 200 parallel port RS232 communication port input fuse manual bypass switch connection terminal cover AUTONOMY TIME BATTERY PACKS GENERALLY IN Protect 1 DESIGN Coupled Autonomy time full load half load min battery cabinets Protect 1 100 Protect 1 150 Protect 1 200 1 x Protect 1 100
44. ment phase the compactness of design was paramount The design also allows you to connect a microphone and speakers As a result the annoying cable clutter on and behind the desk can be avoided Any peripheral units can be switched off via the central power button thereby reducing standby costs Key features e 3 protected sockets one of them rotateable e 2 protected USB chargers e Data line protection for network cable RJ45 e Additional connectors for microphone and headset audio cable extension included e Surge protection up to 36 000 A amp 10 years warranty 90 rotateable earth protected socket protected audio in and output audio cable extension 1 8 m included 2 protected network line USB chargers protection RJ45 Part number Protect Office 600 000 7746 Protect Business Business solution with surge protection Protect your laptop and projector at conferences Thanks to its folding mechanism Protect Business is suitable for conference tables and desktops In addition it offers surge protection for data cables RJ45 and a dual USB charger unit Key features e 6 protected sockets e Surge protection for network cables RJ45 and 2 protected USB charger e Foldable mechanism for conference tables e Dust resistant and childproof sockets e Surge protection up to 36 000 A amp 10 years warranty foldable mechanism 2 protected for space saving USB charger network line protectio
45. n RJ45 Part number Protect Business 600 000 7748 Surge protection Protect Entertainment Intelligent protection for entertainment equipment with Master Slave Function Protect your sensitive equipment and save standby costs With its Master Slave Function the PROTECT Entertainment is especially suited to modern home theatres and music systems If the main unit master is turned off then the electricity supply of the other peripheral units slaves will be automatically cut off In addition this conductor offers surge protection for antenna cables and network cables As a result all your equipment is optimally protected against power surges Key features e 1 master and 3 slave sockets master slave mode can be switched off adjustable master trigger level e 2 outlets always powered e Surge protected antenna connector coaxial e Surge protection for network cables RJ45 e Dust resistant and childproof sockets e Surge protection up to 36 000 A amp 10 years warranty Master Slave Function can be switched off so all outlets are powered network line protection RJ45 surge protected antenna connector Part number Protect Entertainment 600 000 7745 Protect TwinPower Security for various applications with protected USB chargers With PROTECT TwinPower AEG offers you a flexible voltage solution for the desktop Its 7 power outlets provide enough room for all peripheral devices around the
46. n Eh Pro Care Garant Pro Care Garant PLUS Register your UPS within two months from date of Warranty extension to 60 months from the date of purchase and you will get the warranty extention purchase with advanced replacement of the UPS Pro Care Garant for free So we provide an overall within the warranty period This can be optionally warranty for 36 months on UPS and battery arranged during the first year after purchase The registration form is available at Available for the Protect C C Rack D 1 and 1 M www aegpartnernet com series Repairs and individual service measures available on request Service 3 phase UPS Rely on the experts to reduce failure costs and increase system availability Because AEG Power Solutions is a world class system provider you can rely on a global network of 20 Services Centers supported by over 150 field engineers and more than 100 certified service partners around the world From power solution selection to process installation and com missioning our certified experts exceed your expectations Their excellent service helps you achieve the lowest operating cost for your mission critical power solution A Global Service Team renowned for its short response time and trouble shooting efficiency ensures the reliability of your installed power solution Choose the right service maintenance contract for your power solution Pro Care Safe Pro Care Excel Pro Care Premium Service Description An
47. ng United Arab Emirates e aes p Penang Kuala Lumpur Malaysia Malaysia Singapore Due to our policy of continuous development data in this document is subject to change without notice and becomes contractual only after written confirmation Capetown South Africa PERFECT IN FORM AND FUNCTION Mayflex UK Ltd Excel House Junction Six Industrial Park MAYFI J Electric Avenue BIRMINGHAM B6 7JJ United Kingdom Tel 44 0 121 326 7557 Fax 44 0 121 327 5886 Email sales mayflex com Web www mayflex com
48. nty Additional service packages such as warranty extension up to 60 months are available during the first year after purchasing the UPS We also recommend the optional maintenance during a long term usage of the UPS to assure reliability in critical situations Repairs and individual service measures available on request Compact UPS medium sized IT facilities Ei Protect 1 10 to 20 kVA For medium sized data centers protection of cash till systems and facilities 32 10 20 kVA VFI double conversion 3 ph 1 ph yes 6 80 Page Power kVA Technology acc to IEC 62040 3 Input Output Parallel operation Autonomy time min at full load EE Combination Architecture Combination modular UPS medium sized datacenters Protect 1 M 4 to 24 kVA Scaleable and modular high perfor mance UPS system for the IT sector 34 4 24 kVA VFI double conversion 1 ph or 3 phs 1 phe yes internal 10 90 ll Architecture Protect 3 M 2 0 20 to 120 kVA Modular UPS with hot swappable design as scalable solution for medium sized data centers 38 20 120 kVA VFI double conversion 3 ph 3 phx yes internal amp external free configurable Combination Architecture from AEG Power Solutions is the integration of renewable and alternative energy sources into power systems to compensate for efficiency losses and or reduce carbon footprint Page 36 3 phase UPS large data
49. nual scheduled Annual scheduled on site Annual scheduled on site on site preventive preventive maintenance preventive maintenance maintenance including defective parts including defective parts replacement and battery replacement Visual inspection Functional assessments Organic and inorganic P r r contaminants removal Battery efficiency examination Computerized numerical o e diagnostic Parameters adjustment A and optimization Same day repair upon P A customer approval Maintenance protocol registration Functional walk through Software update 24 7 hotline Complementary phone support Standard work week hours Includes travel expenses and on site service engineers Includes defective parts replacement gt Includes battery replacement Battery units replacement based s on overall system lifetime 3 year service contract Subscription at end A A of warranty period 1 Excludes unrelated failures or acts of god Power Solutions Amsterdam Zwanenburg The Netherlands Belecke London United Kingdom Germany Toronto Canada Lannion France e Prague Paris Brame Czech Republic Budapest Hungary Moscow Russia he P Chambray l s Vitoria Spain Os i Vimercate Madrid France Milany Beijing Spain Italy China Dallas Texas Chengdu Shanghai China China Mexico Dubai Hong Ko
50. o nine UPS devices on the CompuWatch CD Control of datacenters with UPS management Network Management Software Motion detector Temperature sensor UPS with SNMP adapter Server At failure alarm via e mail or pop up _4 Web based AEG Network amp Management Software Integrated solution of UPS management The combination of network management software for remote control and the UPS management software CompuWatch offers an integrated solution for administration of several datacenters With the optional sensors shutdown processes can be automated whenever there are problems in the datacenter enviroment An SSL encrypted communication between the UPS and server secures against unauthorized access Special features e Environmental control by sensors like temperature humidity smoke and motion detectors e Secured communication between UPS and server by SSL encryption e Local alerts by actuators like warning light or audible alarm e Alerts via network messages emails oder SMS e Complete automated server management via programmable actions Accessories Hardware Remote Panel Remote signal indicator for professional datacenter management The remote panel displays remote UPS status in real time An additional bar graph shows the current UPS load and remaining capacity in emergency power mode Besides the visual indicators the panel has an acoustic alarm which can be disa
51. of a building The steadily growing number of electronic household appliances and enter tainment units over the last few years has also increased the extent of damage A single power surge can quickly lead to costly damages amounting to thousands of Euros as smaller components often have close tolerance limits for the power supplied If they are damaged the entire unit has to be repaired This is often complicated and costly AEG surge solutions provide effective protection UBERSPANNUNOSSCHUTE ae Hpi i t LES 7 l The following equipment is particularly at risk e Phone systems router e Television LCD and plasma TVs e Game consoles e Computer amp IT equipment e TV receiver Speakers Protect Basic GE Effective surge protection for sensitive home electronics The surge protectors have five outlets for standard grounded power plugs plus one or two wider spaced outlets designed to accommodate larger power adapters The surge protectors include filters to suppress high frequency interference voltages To prevent tangled cables they are also fitted with a cable management bracket at one end Two LEDs indicate whether the power is on and surge protection is active The power switch enables the mains supply to connected equipment to be cut off Key features e Five grounded outlets plus one or two adapter spaced outlets e Power cord 1 8 m with angled plug e Resetable automatic circuit breaker e All
52. oltage e Compact construction variable use due to combination design tower rack e Robust design overload capability and short circuit protection e Intelligent monitoring system with USB and RS232 interfaces e User friendly battery design in hot swappable version from 1500 VA e Operator friendly display for optimal readability configuration e Over voltage protection RJ11 RJ45 for ISDN Fax modem and network e Expansion slot for extension cards SNMP potential free contacts from 1500 VA e Free 36 months warranty on UPS and battery with advanced replacement service registration required Protect B 3000 Rear view SNMP Slot Modem Network Ext j USB sa Surge Protection Batter ia Bugs Output Breaker autonomy time full halfload in min 750VA 1000VA 1500VA 2000VA 3000 VA Standard autonomy time 5 15 5 15 no integrated battery 5 14 Standard autonomy time 5 15 5 15 5 15 5 14 5 14 1 additional BatteryPack 5 15 5 14 24 55 1 additional 19 battery insert 30 80 27 65 24 55 2 additional BatteryPacks 15 45 15 35 45 90 2 additional 19 battery insert 65 150 50 110 45 90 3 additional BatteryPacks 30 80 27 65 55 140 3 additional 19 battery insert 55 140 4 additional BatteryPacks 50 110 40 85 75 180 4 additional 19 battery insert 75 180 5 additional BatteryPacks 65 150 50 110 Protect B output for server and network components Classification VI
53. or 1 PC with 17 TFT Overload deep discharge protection Recharge time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Failure indicators acoustical optical GENERAL DATA Audible noise 1 m distance Operating temperature range Humidity EMC conformity Product safety Overvoltage protection Operation altitude Outlets Equipment colour Size approx W x H x D mm Weight approx Shipment Certification Protect Home UK PROTECT Home 600 VA 300 W 600 000 3933 230 Vac 50 Hz 3 0A 230 Vac 10 50 Hz 1 Hz 2 6 A 2 6 ms typical modified sinewave yes sealed maintenance free 10 Min yes 8h USB and RS232 for status and measurement levels Included for all typical operating systems e g Windows Linux Mac Mains failure overload battery low fault lt 40 dB A fanless 0 40 C 20 90 EN 50091 2 Class A EN 61000 3 2 EN 61000 3 3 EN62040 1 1 surge protection RJ11 Phone Fax Modem F Connector for Satellite TV up to 1000 m at nominal load 4 shockproof sockets 3 x with UPS protection 1 x with surge protection Blackline 125 x85 x300 3 5 kg Mains cord USB and RS232 communication cable management software CompuWatch CD user manual CE Protect A Protect A Uninterruptible security for PCs workst Indication of fault inductions Operating status display L o o Autonomy time min UPS input voltage UPS outp
54. ower supply Key features e Full digital control High reliability no potentiometers High flexibility software controlled parameters Fast dynamic response e Ergonomic control unit with multilingual graphical display e High effi ciency even at low output power Reduced operating costs Reduced air conditioning requirements Reduced battery Ah requirements e Oversized components Higher reliability and MTBF High overload capacity e Output isolation transformer e Standardized modules e Low maintenance e Short circuit resistant e More EMC robust than UPS Standard IEC 62040 2 by a factor of 2 to 3 e Redundant controls Separate microprocessors for Rectifier Inverter Static Switch and Communication e Separate and redundant power supplies for control cards o ou q O e a TT a a a e High protection degree IP rating possible Ready for harsh environment e Strong mechanical design e Remote monitoring and control capabilities programmable e Capable of communicating with computer and control systems SCADA ESD DCS BMS Modbus JBus Profi bus Monitoring software Ethernet SNMP e System and alarm status via volt free contacts e Complete system Protect 3 33 is a true on line double conversion UPS classified as VFI SS 111 according to IEC 62040 3 e This outstanding UPS range features On line operation ensuring permanent service Microprocessor driven control and command sys
55. ration required batteries may have difficulty supply ing the necessary power which often results in systems which are physically much 5 larger than necessary SuperCaps operate on a different principle to batteries and are capable of holding a charge for extended periods without any loss of capacity Batteries however by virtue of their electro chemical com position require high maintenance with cell replacement not uncommon and still present the risk of not having sufficient capacity just when it s needed most SuperCaps provide fast short term peak power for indefinite cycles They can be charged or discharged several times charge isntantly and have a long lifetime up to 20 years They do not release any heat during discharge and are up to 95 efficient in application more efficient in fact than conventional batteries Additionally SuperCaps do not require special storage conditions and maintenance for assured operation Their scalable and modular nature makes them an ideal solution for data centre applica tions They are compact compared to batteries and using 3 D Flexibility from AEG Power Solutions they can be combined with other technologies including fuel cells to provide highly effective energy storage solutions Get 3 D Flexibility and reduce the carbon footprint of your power infrastructure Standby power protection from AEG Power Solutions adds 3 D Flexibility to your energy storage options Whe
56. rfaces dual monitoring Shutdown software on CD Failure indicators acoustic visual display GENERAL DATA Efficiency Audible noise 1 m distance Operating temperature range EMC conformity Product safety Humidity Installation height Equipment colour Size approx W x H x D mm UPS unit Size approx W x H x D mm battery unit Weight approx kg UPS unit Weight approx kg battery unit Shipment Certification Protect 1 040 Protect 1 M UPS module System unit with max 6 x 4 KVA 4 kVA 24 kVA 2 8 kW 16 8 kW n x scalable technology 600 000 3928 600 000 3930 230 Vac 1 N PE or 400 230 Vac 3 N PE 160 300 Vac 1 ph or 277 520 Vac 3 phx 50 Hz 60 Hz 4 Hz 22 A 1 phy bzw 7 3 A 3 phy 132 A 1 phx bzw 44 A 3 phx 0 98 220 Vac 230 Vac 240 Vac 2 50 Hz 60 Hz 0 2 Hz 17 4 A 104 4 A O ms zero transfer sinusoidal THD lt 3 125 for 30 s 130 for 2 s subsequent transfer to bypass mode zero transfer Sel 120 Vdc lU characteristic curve charging voltage 137 Vde charging current max 3 5 Adc free to choose runtime extension with scalable external battery pack available modules with 28 42 or 65 Ah service life 10 12 years EUROBAT yes RS232 RS485 for status and measurement levels communication slot for volt free contacts SNMP Included for all typical operating systems e g Windows Mac Linux Unix FreeBSD Novell Sun etc single licence CompuWatch with a 5 fold networ
57. rvoltage voltage fluc tuations non linear distortions frequency fluctuations etc Modularity provides safety reserves Protect 3 M 2 0 is an uninterruptible power supply which is highly reli able and efficient The modular design of Protect 3 M 2 0 permits a flex ible increase of the UPS power up to 480 kVA maximum with 20 kVA automatic contact hot swap modules This technology allows the system to be extended during operation Modules are hot swappable Additional cabling is not necessary e Hot swappable easy to exchange modules Simple plug amp play principle for replacing modules Module removal addition during operation Automatic connection no additional cable connections necessary e High power reserves with a maximum total power output of 480 kVA Up to 6 UPS modules with 20 kVA each can be installed in one P3 M 2 0 cabinet Up to 4 UPS cabinets up to 120 kVA each can be paralleled e Parallel Operation N X technology allows a flexible adjustment of the power capacity of your UPS at any time At the same time the modular construction pro vides active parallel redundancy and thereby a high safety reservoir Integrated bypass switch e Passive redundancy by static Integrated bypass switch increases availability of the whole system during overload e An additional integrated manual bypass switch protects the system against operational failure and allows bypassing the UPS for maintenance Intelligent monitoring The
58. sectors Since 2005 the company has developed a full range of products for the solar energy industry from solar inverters to turnkey solutions and is investing in solutions that will enable distributed power generation and smart micro grids Committed to providing peak performance With more than 250 engineers technicians and project managers AEG Power Solutions achieves outstanding results in the field of research and development as well as in application engineering This really pays off as more than 70 active patents are currently pending in the power supply sector g 3 UPS FROST SULLIVAN Milestones 2009 AEG Power Solutions becomes a listed company through its holding company 3W Power SA 2008 Renaming of Saft Power Systems Group to AEG Power Solutions 2005 Saft Power Systems Group becomes independent 1998 Saft acquires AEG SVS Power Supply Systems GmbH in Belecke 1995 First UPS in the world with 100 digital control system called Protect 3 1988 Development of a UPS with IGBT transistors single and three phase 1985 First rectifier Profitec S with microprocessor 1972 Development of the first switch mode power supply 5 25 1969 Development of the power controller 1965 Development of the three phase thyristor inverter 1961 Development of the single phase thyristor inverter 1951 DC supply for the Deutsche Bundespost German Federal Post Office 1947 Establishment of
59. t Weight approx kg UPS unit Weight approx kg battery unit Shipment Certification Protect 1 100 Protect 1 150 Protect 1 200 n x technology scalable parallel operation of up to 3 units 10 kVA 15 kVA 20 kVA 7 kW 10 5 kW 14 kW 600 000 4434 600 000 4435 600 000 4436 400 230 Vac 3 N PE 304 478 Vac Bypass 176 261 Vac 50 Hz 60 Hz 4 Hz A gt 0 95 19 A 68 A Bypass 13 A 46 A Bypass 25 A 91 A Bypass 220 Vac 230 Vac 240 Vac 1 50 Hz 60 Hz 0 1 slew rate 1 Hz s 43 4 A 65 2 A 86 9 A O ms zero transfer sinusoidal THD lt 2 130 for 10 min gt 130 for 1 s automatic transfer to bypass mode zero transfer cea short circuit proof 240 Vdc U characteristic curve charging voltage 274 Vde charging current max 4 2 Adc Runtime extension with scalable external battery packs yes RS232 with status message and measured values Communication Slot potential free contacts USB SNMP Included for common Operating Systems Windows Linux Mac single licence CompuWatch with a 5 fold network licence LED bar graph showing UPS load battery capacity Indicators for mains failure overload battery low battery replacement fault gt 90 lt 55 dB A lt 60 dB A 0 40 C up to 1000 m above sea level at nominal load EN 62040 2 Class C3 EN 62040 1 1 0 95 non condensing Blackline 260 x 720 x 670 260 x 720 x 570 Protect 1 100 BP 260720795 Protect 1 BP 20 39 kg 55 kg 135 kg Protec
60. t 1 100 BP 170 kg Protect 1 BP 20 Parallel operation cable communication cable management software CompuWatch CD user manual CE Protect 1 M Protect 1 M Modular high performance UPS system e High power reserves max 24 kVA total output e High safety reserves n x technology e Integrated static bypass switch e 3 phase or 1 phase connection of the complete system 1 phase output e High autonomy time during power failure e Manufacturer independent standard batteries e Intelligent battery management e Hot swappable easy to exchange modules e Module design in slide in type in the compact tower e Communication module with LCD display Dual monitoring interface with extension slot e Software CompuWatch on CD Advantages of n x technology e higher reliability e easy to increase overall capacity e modules hot swapable without any interruption Front view Expansions Slot RS485 RS485 RS232 RS485 Expansion slot for e relaycard with potential free contacts e SNMP and SNMPpro cards with connector for remote control and sensors Rear view n x technology Redundancy level QUANTITY OF UPS MODULES Load 1 module 2 modules 3 modules 4 modules 5 modules 6 modules 4 kVA no n 1 n 4 n 5 redundancy 4 kVA n 2 n 3 8 kVA 12 kVA 16 kVA 20 kVA 8 kVA no n 1 n 2 n 3 n 4 redundancy 4 kVA 8 kVA 12 kVA 16 kVA 12 kVA no n 1 n 2 n 3 redundancy 4 kVA 8 kVA 12 kVA
61. tem to provide reliable power supply e A battery management system that boosts life time and cuts operating costs e A broad range of output power ratings battery autonomies and options to meet the needs of complex industrial applications e The UPS offers a very high level of protection for users and connected equipment High intermittent overload capacity High level short circuit strength N conductor with full loading capacity 3 phase systems Excellent dynamic response can easily handle high cyclic loads e Redundant and individually monitored fans e Compatible with vented Lead Acid Valve Regulated Lead Acid VRLA and Nickel Cadmium batteries e Intelligent Battery management test and status diagnostics e Designed to operate with Diesel Generators e Frequency converter operation e EcoMode as option nd internet nodes Protect 3 33 MODEL 3 33 10 Type power at cos 0 8 lag in kVA 10 RECTIFIER UNIT Input nominal voltage operating range min max Frequency Input current in A at nominal load 17 Input current in A at nominal load battery charging Charging characteristic to IEC 478 10 Nominal DC voltage 21 Max charging voltage Total harmonic distortion Standard 6 pulse Optional Filter INVERTER UNIT Nominal DC input min max Nominal AC voltage Adjustable min max Static response Dynamic response Correction time Frequency Frequency tolerance without mains Frequency synchron
62. the UPS to be configured and monitored in HP OpenView SunNet Manager or other network management software The PRO version of the SNMP adapter can additionally incorpo rate room access control air conditioning and smoke and fire detector systems In combination with the EnvironmentManager the SNMP PRO Adapter is even capable of processing tempera ture and humidity sensor data SNMP adapter 600 000 4036 SNMPpro adapter 600 000 1271 External SNMPpro adapter 800 000 9965 Temperature sensor 800 002 0878 External relay board 600 000 5994 Service Compact UPS Service Your Power Partner for reliability Only a professionally serviced and maintained UPS offers the highest possible availability with effective cost control Based on our high standards and decades of experience we are also cost effective efficient and rapid when it comes to servicing Pro Care Comfort Maintenance service for PROTECT C 1 and 1 M Can be ordered as a service package at any time For the first 24 months after the initial purchase we provide a comprehensive advanced replacement service for the device and battery from the Compact UPS series Protect Home A B B PRO C C Rack D 1 1 M Additional service packages which address all of the user s needs are available when purchasing the UPS These packages ensure optimal cost control over a period of up to 60 months The following service packages are available 36 mea
63. ther you choose any of our standard and modular UPS systems for your data centre or ask us to design a custom solution to meet a specific requirement 3 D Flexibility gives you the option to specify how energy is stored to ensure ride through power transients For example you could select a super capacitor Storage solution to replace or enhance a bank of batteries Just ask us how we can design a solution incorporating fuel cell SuperCap or battery storage to help reduce the environmental impact of your facility and reduce its running costs Protect 3 M 2 0 Protect 3 M 2 0 Modular UPS system for medium A technically convincing solution that is flexible to fulfill the growing requirements of modern datacenters e Sufficient power and security reserves e Easy handling and low maintenance costs e Optimal price performance ratio Power failures overloads and undervoltage can lead in the worst case to loss of data Denied access to company critical applications almost always leads to operational disturbances even to loss of production Networks workstations intranet and internet servers telecommunica tions and other company applications must therefore be available at all times and must also be protected against any disturbances to the power supply Implementation of the VFI double conversion technology of AEG s Protect 3 M 2 0 protects your system reliably against all power supply problems e g power failure surges unde
64. tion telephone fax modem USB RS232 Protection against data loss through uninterrupted power protection with a size from 600 VA the Protect Home offers professional and economical protection against power outages surges and sags Protection against Power Outages and dangerous Power Spikes e Microprocessor controlled robust UPS technology for power outages and dangerous power spikes e Complete CompuWatch Software plug and play e USB and RS232 interface for overview and control from a PC e Overvoltage protection for satellite TV s as well as dataline protection for telephones faxes and modems e User friendly battery design e Free 36 months warranty on UPS and battery with advanced replacement service registration required LED lights with traffic light function for clear information of the current operating condition Excellent Provisions all around protection for satellite TV Telephones Faxes or Modems as well as USB and serial connections for commu nication with your PC Protect Home FR and Multimedia Protect Home Classification VFD SY 322 acc to IEC 62040 3 Type power Part number UPS INPUT Input voltage Frequency Current consumption max UPS OUTPUT Rated output voltage Rated output voltage in battery mode Frequency in battery mode Output current Transfer time at mains outage Voltage waveform Overload Short Circuit Protection BATTERY Type Autonomy time f
65. ut voltage Display screen of Protect A 1000 A 1400 Overvoltage protection for data interface fax modem UPS output with overvoltage protection UPS outputs with battery backup and overvoltage protection UPS input Mains input fuse Rear view A 500 A 700 Protection against power failure and voltage fluctuations e Modern VI line interactive technology against power failure and dangerous overvoltage e Automatic voltage regulation against mains voltage deviations AVR e Double mains filter against voltage peaks e Easy installation ensured by cables supplied and optimum operation e Use of sealed maintenance free lead acid batteries with exhaustive discharge protection e USB port and RS232 interface e Data line protection for phone fax modem RJ11 and from 1000 VA on inclusive network protection RJ45 e Free 36 months warranty on UPS and battery with advanced replacement service registration required Load Battery voltage Overvoltage protection for data interface fax UPS outputs with modem and network battery backup and overvoltage protection RS232 UPS outputs with UPS input l overvoltage protection Mains input miniature circuit breaker Rear view A 1000 A 1400 Protect A ations and telephone systems Classification VI SY 322 acc to IEC 62040 3 Type rating Part number UPS INPUT Nominal connection voltage Voltage range without battery operat
66. uter centres file servers telecommunica tions or industrial processes the PROTECT 4 means additional safety and reliability for e Remote servicing via modem your systems e Comprehensive service support e Redundant fans Environmentally friendly The PROTECT 4 offers the highest reliability with efficient modern technology and 12 pulse rectifier for sinusoidal input current consumption to DIN 41773 Thanks to its excellent efficiency level of up to 94 up to 8000 can be saved per year in every day online use Increased power and reliability through parallel operation The PROTECT 4 can be used in parallel operation with up to 8 units This increases the power capacity or allows for even greater safety via N 1 redundancy Unique control capability with three custom microprocessors A key feature of the unit s design are the three control microprocessors These were specially developed by AEG PS for use in UPS They monitor and control the rectifier inverter and static switch units simultaneously Protect 4 33 ters and internet nodes Type power at cos 0 8 lag in kVA 160 220 300 400 500 600 800 1000 RECTIFIER UNIT Nominal voltage in V 3 x 400 Operating range min max in V 340 460 Frequency in Hz 45 66 Input current in A at nominal load 259 357 486 649 811 O73 1300 1624 Input current in A at nominal load battery charging 328 451 615 820 1025 1230 1600 2000 Charging characteristic acc IEC 478 10 IU Nominal DC
67. utput current at 230 Vac Transfer time at mains outage Voltage waveform Overload response online mode Crest factor Short circuit response BATTERY Type Rated voltage Overload deep discharge protection Recharge time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Failure indicators acoustical optical GENERAL DATA Efficiency total Audible noise 1 m distance Operating temperature range EMC conformity Product safety Data lines protection Humidity Installation height Number of outlets Rack Equipment colour Size approx W x H x D mm Rack Battery Weight approx Rack Battery Shipment Certification C 1000 R 1000 VA 700 W 600 000 3846 600 000 3851 600 000 4342 C 2000 R 2000 VA 1400 W 600 000 3847 600 000 3852 600 000 4343 C 3000 R 3000 VA 2100 W 600 000 3848 600 000 3852 600 000 4344 Protect C Rack and electronic data processing in medium sized companies C 6000 R 6000 VA 4200 W 600 000 3850 600 000 3927 220 Vac 230 Vac 240 Vac 160 300 Vac 176 276 Vac 50 Hz 60 Hz 4 Hz 0 96 0 98 7A 10A 16 A 31A 220 Vac 230 Vac 240 Vac 2 220 Vac 230 Vac 240 Vac 1 50 Hz 60 Hz 0 2 50 Hz 60 Hz 0 1 43A 8 7 A 13 A 26 A O ms zero transfer sinusoidal THD lt 4 140 30 s 150 300 ms 130 10 min gt 130 1 s subsequent transfer to bypass mode Sal short circuit proof sealed maintenance free 36 Vdc 96
68. v v v Mobiles amp MP3 players v Small home appliances v v Surge protectors OFFICE Protect Travel Protect Office Protect TwinPower Protection on the move with Compact protection for PC and Business solutions with protected USB chargers peripheral equipment Surge protection and USB chargers 1 3 6 2 z v y 2 2 2 y y flexible mains audio folding input cable interface mechanism y v y v v v y v y lt lt a S ME Compact UPS Home Office IT Protect Home GE FR UK 600 VA Comprehensive protection for satellite TV phone fax or modem Page 18 Power kVA 0 6 kVA Technology acc to IEC 62040 3 VFD offline Input Output 1 ph 1 phx Parallel operation no Autonomy time min at full load 3 UPS Cini feet G Fite a UPS Configuration a ogre oof beeeet m le Se Ernstig Byrne Cece tet off T E i iM ins a ih GET k E maa Enable Disable Burzer Actio pe a E Glia rati iz Er ki is a a Lee Fo IF inr L E TEE i TP iF in ar a mE Hi ee al l nn ity iam T o E 1 ET F maii Protect A 500 to 1400 VA Protects PCs workstations and phone systems 20 0 5 1 4 kVA VI Line interactive 1 ph 1 ph no 3 Software CompuWatch Our shutdown and UPS management software CompuWatch is provided on CD for all single and three phase UPS devices e Storage of system operations and graphical representation o
69. y exchange e rack usage Protect D Classification VFI SS 211 acc to IEC 62040 3 Type rating Part number UPS Part number BatteryPack UPS INPUT Nominal input voltage Voltage range w o battery operation load dependent Frequency automatic detection Mains current system disturbance factor Current consumption at full load max UPS OUTPUT Rated output voltage adjustable Frequency in battery converter mode Nominal output current at 230 Vac Changeover time at mains failure Voltage curve shape Overload ability double conversion mode Overload ability battery mode Crest factor Short circuit ability BATTERY Type Nominal DC voltage intermediate circuit Battery management Charging time to 90 of rated capacity COMMUNICATION Interfaces Shutdown software on CD Alarms acoustical optical GENERAL DATA Efficiency at full load ECO mode Efficiency at full load double conversion mode Operating temperature range Inherent noise 1 m distance full load Humidity EMC conformity Product safety Max site altitude Load outputs Rack Casing Material Dimensions W x H x D mm Rack Battery Weight approx Rack Battery Delivery scope Conformity D 1000 D 1500 D 2000 D 3000 1000 VA 1500 VA 2000 VA 3000 VA 900 W 1350 W 1800 W 2700 W 600 000 8434 600 000 8436 600 000 8437 600 000 8438 600 000 8441 600 000 8442 600 000 8443 200 Vac 230 Vac 240 Vac 160 276 Vac 18