Home

Chief K4G410B flat panel desk mount

image

Contents

1. Figure 22 Figure 23 16 Installation Instructions K4G4X 5X 6X Series Display Leveling If the array sags after attaching displays adjust the connection point to the arms until an even mount is achieved Refer to the appropriate section depending on whether the array sags to the inside or the outside See Figure 24 Sag to the Outside Sag to the Inside Figure 24 For Sag to the Outside 1 Loosentwo screws holding column arms to outer array arms See Figure 25 2 Lift up on array arm slightly and slide connection plate towards the outside of the array until an even mount is achieved See Figure 25 3 Tighten two screws holding column arms to outer array arms See Figure 25 Figure 25 For Sag to the Inside 4 Loosen two screws holding column arms to outer array arms See Figure 26 5 Lift up on array arm slightly and slide connection plate towards the inside of the array until an even mount is achieved See Figure 26 6 Tighten two screws holding c
2. ITEM DESCRIPTION K4G410 K4G510 K4G610 K4G420 K4G520 K4G620 Screw Button Head Cap 10 32 x 5 16 4 4 4 8 8 8 B Screw Button Head Cap 10 32 1 4 4 4 8 8 8 C Screw Button Head Cap 10 24 x 1 1 8 4 4 4 8 8 8 D Screw Flat Head Cap 8 32 x 1 2 4 4 4 8 8 8 E Screw Flat Head Cap 1 4 20 x 1 1 4 8 8 8 8 8 8 F Column Arm Single Tier Models 2 2 2 G Column Arm Dual Tier Models 2 2 2 H Array Connector 1 1 J Array Plate 2 2 2 4 4 4 K Column Cap 2 2 2 2 2 2 L Base Cover 2 2 2 2 2 2 M Grommet Screw and Base 2 2 2 2 2 2 N Grommet Plate 2 2 2 2 2 2 Cable Management Cover 9 1 2 4 4 4 Q Cable Management Cover 4 1 2 6 5 6 8 10 8 R Kit Array Centris Faceplate Hardware includes M1 M5 4 5 6 8 10 12 RI Screw Phillips Pan Head M4 x 30mm 16 20 24 32 40 48 R2 Screw Phillips Pan Head M4 x 20mm 16 20 24 32 40 48 R3 Screw Phillips Pan Head M4 x 12mm 16 20 24 32 40 48 R4 Spacer 3 8 16 20 24 32 40 48 R5 Spacer 3 4 16 20 24 32 40 48 T Hex Key 3 32 1 1 1 1 1 1 V Hex Key 1 8 1 1 1 1 1 1 W Hex Key 3 16 1 1 1 1 1 1 X Hex Key 5 16 1 1 1 1 1 1 Y Hex Key 5 32 1 1 1 1 1 1 Z Cable Tie 20 20 20 20 20 20 AA Array Arm Left 1 1 1 2 2 2 BB Array Arm Right 1 1 1 CC Center Plate K4G5X Models 1 2 DD Center Plate K4G6X Models
3. gno DI em AA BB mounting tab faceplate rn e n Figure 5 IMPORTANT Connect faceplates to the outer array arms as shown in Figure 5 when installing K4G410 420 510 520 mounts Connect faceplates to the inner array arms when installing K4G610 620 mounts Minor adjustments to the connection location may need to be made in order to compensate for sagging See Display Leveling Section for details 15 Use two 10 32 x 5 16 button head cap screws A to loosely secure column arms F or G to outside arrays AA and BB See Figure 6 IMPORTANT Do not tighten screws at this time 15 2 AA BB Figure 6 Installation Instructions K4G4X 5X 6X Series 16 Insert array connector H K4G410 420 models or connectors pre installed on both end of center plates CC or DD into left and right array arm openings See Figure 7 17 Slide array plates J into grooves on back of array arms lining up holes on plates with holes in arms See Figure 7 fi K4G410 420 K4G510 520 Hy rear view Figure 7 18 Use two 8 32 x 1 2 flat head cap screws D to secure each array arm to connector plates See Figure 8 and See Figure 9 19 Use four 10 24 x 1 1 8 button head cap screws C to secure array arms AA and BB to
4. 1 2 EE Handle 2 2 2 4 4 4 Installation Instructions K4G4X 5X 6X Series Assembly And Installation 1 Use four 1 4 20 x 1 1 4 flat head cap screws E to secure WARNING The K4G4X 5X 6X Series mounts were grommet plate N to column F or G Make sure longer designed to mount displays between 19 23 in width Do NOT legs of grommet plate are aligned with the front of column install displays smaller than 19 in width or larger than 23 in See Figure 1 width NOTE Column 1 shows monitor width not diagonal size Average K4G410 K4G510 K4G610 Weight Wi Dn Monitor Width in 19 68 69 5 20 8 54 68 72 25 21 8 56 25 68 75 5 22 8 5 57 75 68 75 77 5 23 9 59 25 69 75 77 5 IMPORTANT Mounts must be installed parallel to each other on the desk See Figure 2 Figure 1 NOTE Table assumes a average display depth of 2 35 2 R 1f I R 4 If hole doesn t already exist drill a hole in desk with a diameter between 1 2 and 3 at desired mounting location 3 Locate a flat surface thickness minimum of 1 to maximum See Figure 2 of 5 on which to mount the array assembly IMPORTANT Use the numbers provided in the table 5 as a guide to determine distance between columns F or G Exact distances may vary slightly with other monitor
5. K4G410 COLUNN CENTER TO CENTER pe DISTANCE IS DEPENDANTON NO NTO R WEG HT AND WIDTH 1 1 WAL MONITOR HEIGHT H 0 run 11 TILTA DIISTA ENT SURFACE DEPTH K4G510 LUN N CENTER TO CENTER DISTANCE IS DEPEN WOW MTOR WEG HT AND WIDTH TH K4G4X 5X 6X Series Installation Instructions DIMENSIONS CONTINUED K4G610 COLUMN CENTER TO CENTER DISTANCE I DEPENDANTON MON TOR WEG RT AND WIDTH SM Wl E dti P Kee VESA 100 X 100 75 X 75 COW PA TILE INTERFACE 12 TILT AD LU STH ENT K4G420 12 0 EXTEN S10 0 UR COLUMN CENTER TO CENTER DISTANCEISDEPENDANTON MON TOR WEI HTAND III VESA 100 X 100 75 X 75 d ell vil COMPATIBLE INTERFACE 12 TILTADIUSTH ENT K4G4X 5X 6X Series Installation Instructions DIMENSIONS CONTINUED K4G520 COLUM CENTER TO CENTER DISTANCE IS DEPENDANTON MONITO R WEG RTA NOD W DT UN 109 1 12 0 EXTENSION WW UN COLUNN CENTER TO i DISTANCEISDEPENDANTON S T EI N IDTK REIGHT 3 VESA 100 75 100 5 COMPATIBLE INTERFACE 12 TILTADIUSTH
6. ENT 5 Installation Instructions K4G4X 5X 6X Series LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com lapis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis a pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand A mano Von Hand Com a m o A mano Met de hand la main Optional Opcional Optional Opci
7. INSTALLATION INSTRUCTIONS K4G620 Large Kontour Articulating Array Arm Grommet Series GCHIEF K4G4X 5X 6X Series Our Mounts Your Vision K4G4X 5X 6X Series Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment o
8. ble plate back into slot at bottom of faceplate e assembly See Figure 18 3 Soco to secure desired faceplate position See 6 Reinstall socket head cap screw removed in Step 1 to secure faceplate assembly to array arm See Figure 18 G Figure 20 removable plate OR AN lt Figure 18 Lateral Shift 1 Loosen knob on top of faceplate assembly until faceplate can slide freely along array See Figure 19 2 Adjust lateral position as desired See Figure 19 3 Tighten knob to secure lateral position See Figure 19 K4G410 shown 0 9 Figure 9 15 K4G4X 5X 6X Series Installation Instructions K4G610 620 K4G410 420 60 2 O a Oax K4G510 520 Figure 21 Cable Management 3 Route cables from display through cable management 9 covers Q on array arms as desired See Figure 23 1 Install41 2 cable covers Q to array arms See Figure 21 4 Route cables along swing arms using cable ties Z to 2 Install two 4 1 2 cable covers Q to single tier column arms secure cables to arms See Figure 23 F or four 9 1 2 cable covers P to dual tier column arms 5 R A A oute cables through cable management covers P or Q on G S66 Figure 21 6r See Figure 22 columns as desired See Figure 23 Dual Tier Models K4G420 520 620
9. connector plates and brackets See Figure 8 and See Figure 9 K4G410 420 front view Figure 8 K4G510 520 610 620 left side Get E K4G510 520 610 620 right side front view Figure 9 11 K4G4X 5X 6X Series Installation Instructions 20 Use four 10 32 x 1 button head cap screws B to secure two handles EE to array arms AA and BB or K4G6X center plate DD See Figure 9 NOTE Handles attach to right and left arrays AA and BB for all K4G4 and K4G5 models Handles attach to K4G6X center plate for K4G6X models K4G410 Figure 10 12 Display Installation WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located on the K4G4X 5X 6X Series mounts up to and including the display does not exceed 15 lbs 6 8 kg per display CAUTION Using screws of improper size may damage your display Proper screws will easily thread into display mounting holes NOTE Supplied screws R1 R2 and R3 may not fit properly for all displays See display s operating instructions for details Flush Mounting Holes 1 Position faceplate in desired mounting position Adjust as required before proceeding See Height Adjustment Section for details 2 Using Phillips screwdriver caref
10. crews Do not over tighten 13 K4G4X 5X 6X Series Installation Instructions Adjustments Pivot Adjustment Column Arm 1 Use handles EE to extend or collapse column arms as desired See Figure 15 2 Optional Loosen or tighten column arm pivot tension screws as desired to increase or decrease pivot tension See Figure 15 arms extended K4G610 shown pivot tension screws Figure 15 Height Adjustment 1 Loosen socket head cap screws holding column arm to column See Figure 16 Adjust column arm to desired height See Figure 16 Tighten socket head cap screws to lock column arm s position See Figure 16 NOTE The height on both columns should be adjusted simultaneously to ensure a level mount 14 Figure 16 Faceplate Assembly Removal 1 Remove socket head cap screw from bottom of faceplate assembly See Figure 17 2 Slide out removable plate from bottom of faceplate assembly See Figure 17 removable plate SS Figure 17 3 Remove faceplate assembly from array arm See Figure 17 Installation Instructions K4G4X 5X 6X Series To Reattach Faceplate Assembly Pitch Roll Yaw Adjustment 4 Place faceplate assembly on array arm at desired mounting 1 Loosen knob on top of faceplate assembly See Figure 20 position See Figure 18 2 Adjust pitch roll and or yaw as desired See Figure 20 5 Slide remova
11. olumn arms to outer array arms See Figure 26 0 9 Figure 6 NOTE Ifthe mount still sags it may be necessary to move one or both of the connection points to the other bar of the array IMPORTANT Remove all displays from array prior to moving the faceplate connection from one array bar to the other 17 K4G4X 5X 6X Series Installation Instructions 18 Installation Instructions K4G4X 5X 6X Series 19 K4G4X 5X 6X Series Installation Instructions USA International G CHIEF Our Mounts Your Vision Europe Chief a products division of Milestone AV Technologies Asia Pacific 8800 002432 Rev00 2014 Milestone AV Technologies www chiefmfg com 04 14 lt lt lt lt TU 6436 City West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477
12. onal Opzionale Optie En option C y d 1 2 Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit Installation Instructions K4G4X 5X 6X Series TOOLS REQUIRED FOR INSTALLATION e in 1 2 IW Ne DAN AND 5 16 included 5 32 included 1 8 included 3 32 included Refer to Table 1 for quantities of parts ur lt a A 8 0 D 1 0 32 X 5 1 EN EN 0 32 x1 10 24 x1 1 8 8 32 X 1 2 J E 1 4 20 x 1 1 4 Column arm single tier Column cap Base cover G Column arm dual tier S S ER S P H M 9 1 2 cable cover N 4 1 gt cable cover ES Grommet screw and base NN Grommet plate R Display Mounting Hardware N center pla S e e e Gi S 3 RI R2 R3 R4 M4x30mm M4x20mm M4x12mm 3 8 o 3 32 1 8 3 16 5 16 5 32 Cable tie Handle K4G4X 5X 6X Series Installation Instructions Table 1 Parts
13. r voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located on the K4G4X 5X 6X Series mounts up to and including the display does not exceed 15 Ibs 6 8 kg per display WARNING The K4G4X 5X 6X Series mounts were designed to mount displays between 19 23 in width Do NOT install displays smaller than 19 in width or larger than 23 in width WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors SAVE THESE INSTRUCTIONS Installation Instructions K4G4X 5X 6X Series DIMENSIONS
14. s then select the longer spacer IF recess DEPTH is THEN use spacer AND screw 3 8 or less R4 3 8 long R2 M4 x 20mm More than 3 8 up to and including 3 4 R5 3 4 long R1 M4 x 30mm CAUTION Using screws of improper size may damage your display Proper screws will easily and completely thread into display mounting holes 3 Using Phillips screwdriver carefully install two selected screws R1 or R2 through selected spacers R4 or R5 into the upper mounting holes on the display Thread screws completely into display then back out 3 complete turns See Figure 13 4 Pick up and align display so that screws R1 or R2 installed on the back of the display in the previous step fit into the mounting holes on the faceplate Lower the display firmly into place See Figure 13 R1 or R2 x Os R4 or R5 2 faceplate array arm not shown for clarity _ Figure 13 Slide two remaining selected spacers R4 or R5 in between faceplate and display positioning them over the ower two mounting holes See Figure 14 Install two remaining selected screws R1 or R2 through lowertwo mounting holes on faceplate selected spacers R4 or R5 into the ower mounting holes on the display See Figure 14 R1 or R2 x 2 faceplate array arm not shown for clarity R4 or R5 x 2 Si Figure 14 Tighten all four s
15. s 6 in order to achieve a level mount Position mount on desk so that center hole of grommet plate N is centered over grommet hole See Figure 2 Insert grommet screw M through grommet hole and thread into center hole of grommet plate N See Figure 2 7 Tighten grommet screw M until grommet base is tightened against underside of desk and mount is securely mounted to desk See Figure 2 8 Repeat Steps 4 7 for to install second column Figure 2 K4G4X 5X 6X Series Installation Instructions 9 Carefully manipulate base cover L to create an opening large enough to wrap cover around array column See Figure 3 10 Wrap base cover L around column and slide it down until base cover fits securely onto grommet plate N See Figure 3 Figure 3 11 Tightentwo socket head cap screws to secure column arms F or G at desired height See Figure 4 12 Install column cap K to column F or G See Figure 4 Figure 4 13 Repeat Steps 9 12 for second column 14 Hang right and left array arms AA and BB onto column arm F or G faceplates using the mounting tab on the faceplate See Figure 5 10 connector plate to use connector plate to use for K4G610 620 for K4G410 420 510 520
16. ully install two M4 x 12mm Phillips pan machine screws R3 into the upper mounting holes on the display Thread screws completely into display then back out 3 complete turns See Figure 11 faceplate array arm not shown for clarity Figure 11 3 Pick up and align display so that screws R3 installed on the back of the display in the previous step fit into the mounting holes on the faceplate Lower the display firmly into place See Figure 11 Installation Instructions K4G4X 5X 6X Series 4 Using Phillips screwdriver install two M4x12 mm Phillips pan machine screws R3 through the ower mounting holes on faceplate into the display See Figure 12 faceplate oQ R3 2 array arm not shown for clarity Figure 12 5 Tighten all four screws R3 Do not over tighten NOTE If roll adjustment is desired for center faceplate do not tighten screws 6 Repeat Steps 1 5 for other displays 7 Proceed to Cable Management Section Recessed Mounting Holes NOTE If faceplate does not fit into recessed area of display proceed with the steps in this section 1 Determine depth of recessed mounting holes relative to back surface of display against which faceplate will contact 2 Select proper length spacer and screw from table below NOTE All spacers used should be the same length If the recess depths result in multiple spacer length